电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

SM134G0

器件型号:SM134G0
器件类别:半导体    其他集成电路(IC)   
厂商名称:NEC ( Renesas )
厂商官网:https://www2.renesas.cn/zh-cn/
下载文档

文档预览

SM134G0器件文档内容

                                         DATA SHEET

                                                  Thermal Cutoff SEFUSETM

                        SM/G SERIES

                   FUSIBLE ALLOY THERMAL SENSITIVE TYPE,
0.5 AMPERES (250 Va.c.) and 3 and 5 AMPERES (50 Vd.c.) Rated Current

    The NEC's SEFUSE (SM/G series) is a small, solid and reliable thermal cutoff that can be used under 0.5 A / 250
Vac. 3 and 5 ampere / 50 Vdc. electrical rating type, added to the product line-up lately, is also available. It
protects home appliances and industrial equipment from fire and accident by opening of electrical circuit if it
senses an abnormal temperature rise.

FEATURES
  TM Approved by UL (USA), CSA (Canada), VDE (Germany), BEAB (UK) and MITI (Japan)
  TM Very small
  TM Conpact, durable and veliable by hermetic seal structure.
  TM Excellent sensitive to abnormal temperature rise and high accuracy in operation.
  TM Stable characteristics in a long-term.
  TM Capable of opening at a cutoff current of AC 0.5 amperes and DC 3 and 5 amperes.
  TM One shot operation.

APPLICATIONS                                                                1.6  0.53
    Transformers
    Motors
    Battery packs
    Electric home appliances
    Electric Industrial equipments,
    Office automation equipments, etc.

OUTLINE DIMENSIONS (Unit : mm)

                                                            0.53

40(70)                                                              5.0    40(70)
                                                                  85(145)

        Note: Dimensions in parentheses are for long lead devices.

                                        The information in this document is subject to change without notice.               1992 (1997)

Document No. EM0255EJ5V0DS00 (5th edition)
Date Published March 1998 M
Printed in Japan

                                                                                                                        
SM/G SERIES

MARKING

                       MITI                      SM/G SERIES                     Brand name
                       approved mark
                                                    SEFUSE                       Part number
                                                      110 GO                     (First two letters "SM" are omitted)

               Production control No.                 Tf 115C                   Rated functioning temperature
                       Rated current 0.5A 250V ~                                 Rated voltage

                Designation of Production Control No.

                            810              (example)

                                         Sub-Lot No.

                                         Production month (1 to 9 as Jan. to Sep. and X, Y, Z as Oct., Nov. and Dec.)

                                         Production year (last figure of A. D.)

                The marking of electrical ratinga is only the AC ratings and the DC ratings is not indicated.

TYPE NAME DESIGNATION
               SM 110 G 0

                                                 Lead Length (0 : standard lead type, 1 : long lead type)
                                                 Series Name (SM/G series)
                                                 Operating Temperature
                                                 Type Name (SM type)

STANDARD RATINGS

(AC Electrical Ratings)

           1)      Rated     Operating   TH         TM    Rated Rated                         Safety Standard
   Part        Functioning  Temperature  Th         Tm   Current Voltage UL
               Temperature               TC                                              CSA     VDE BEAB
Number                                           115 C
                                                 125 C
SM095G0 100 C              95   +5  C  65 C   140 C                                          6778.2                   33466
                                 0              145 C                                                                   33472
                                                 155 C                                                                   33467
SM110G0 115 C              1102 C 80 C       200 C                                          1171
                                                                                                                          33468
                                                                                                 0003                    33467

SM126G0 131 C              1262 C 96 C               0.5 Aac   250 Vac       E71747 LR52330                4)  C0743
                                                           (res.)    (res.)
SM130G0 135 C              1302 C 100 C                                                      ( )6778.2
                                                                                                  4510
SM145G0 150 C              1452 C 115 C                                                       1005

SM134G0 139 C              134  +3  C  104 C                                  2)
                                 2

(DC Electrical Ratings)

           1)      Rated     Operating   TH           TM Rated Rated                          Safety Standard
   Part        Functioning  Temperature  Th           Tm Current Voltage UL
               Temperature               TC                                              CSA     VDE BEAB
Number

SM095G0 100 C              95   +5  C  65 C 115 C 3 Adc                                                               3)
                                 0

SM110G0 115 C              1102 C 80 C 125 C

SM126G0        131 C       1262 C 96 C 140 C        5 Adc 50 Vdc            E71747
SM130G0        135 C
                            1302 C 100 C 145 C

SM145G0 150 C              1452 C 115 C 155 C

SM134G0 139 C              134  +3  C  104 C 200 C                           2)
                                 2

       Notes 1) : The type names are for standard lead. When long lead type is required, change the last number "0" to "1".
                  2) : Under application
                  3) : There is no regulation about d.c. electrical ratings in the Electrical Appliance and Material Control Low of Japan.
                  4) : The VDE recognized file number had been changed in February 1998. The number in parentheses are previous
                        file number.

2
                                                                             SM/G SERIES

                                         Definition of Terms

q Rated Functioning Temperature
   Rated functioning temperature is the operating temperature of the thermal cutoff, measured using the method
   specified in the safety standard. In Electrical Appliance and Material Control Law of Japan, case operation
   should be within the specified operating temperature range of 7 C. In standards that comply with the IEC
   standard (such as UL, CSA, VDE, BEAB), it is called the rated functioning temperature, and should operate
   within the prescribed temperature range of +0/10 C.
   It is represented by the symbol TF in the UL standard, and by the symbol Tf in the CSA, VDE and BEAB
   standards.
   In SEFUSE, a temperature that complies with both standards is set as the rated functioning temperature, and
   is indicated on the body of the thermal cutoff.

q Operating Temperature
   Operating temperature is the operating temperature range when the thermal cutoff is made to operate inside
   a constant temperature oven whose temperature is raised at the rate of 1 C/min. while a detection current of
   100 mA or lower is applied.
   The operating temperature is a standard set by NEC and is not specified by a safety standard.

q TH, Th. Tc (Holding Temperature)
   Holding temperature is the maximum temperature at which, when applying a rated current to the thermal
   cutoff, the state of conductivity is not changed during 168 hours.
   It is represented by the symbol TH in the UL standard, Th in the CSA standard, and Tc in the VDE and BEAB
   standards.

q TM, Tm (Maximum Temperature Limit)
   Maximum temperature limit is the maximum temperature for which conductivity does not occur again after
   thermal cutoffs operation.
   It is represented by the symbol TM in the UL standard and by Tm in the CSA, VDE and BEAB standards.

q Rated Current
   Maximum alternating current that can pass through the thermal cutoff and that the thermal cutoffs can cut off
   the circuit in safety and reliability.

q Rated Voltage
   Maximum circuit voltage that the thermal cutoffs can cut off the circuit in safety and reliability.

                                                                                                                                                                                        3
   SM/G SERIES

    Performance Data

    SM/G Series

                                  Temperature Rise                                                                                                        Response Time

                         SM095G0                                                                                                                ,,,,,,, , 30

                         SM110G0

                         SM126G0                                                                                                                  , , , ,SM095G0

   10                    SM130G0
                         SM134G0

   Temperature Rise (C)                                                                                                                          , , , , , 20
                                                                                                                Time for opening after immersion  ,,,,,, , ,SM134G0
                                                                                                                   into oil (seconds)             , ,,, 10              SM110G0

                                                                                                                                                                        SM126G0
                                                                                                                                                  ,,,,,,,,,,,,,,,,,,, 0
                                                                                                                                                                        SM130G0

   5                                                                                                                                                                    SM145G0

                                                                       SM145G0                                                                        , , Temperature Difference (C)

                                                                                                                                                      10  20   30

   0                     1        2           3       4                5

                            Pass-through Current (A)                                                                                                  (oil temp. minus operating temp.)

                         Initial Characteristics                                         High Temperature Storage Test

                   146            106         3.0                5.0                                                                              +5                    @125C
   SM145G0 145
                                  105         2.0                4.0            SM145G0                                                           0
                   144
                                  104         1.0                3.0                                                                              5

                   135            106         3.0                6.0                                                                              +5                    @115C
   SM134G0 134
                                  105         2.0                5.0            SM134G0                                                           0
                   133
                                  104         1.0                4.0                                                                              5

                   131            106         3.0                6.0                                                                              +5                    @110C
   SM130G0 130
                                  105         2.0                5.0            SM130G0                                                           0
                   129
                                  104         1.0                4.0                                                                              5

                   127            106         3.0                6.0                                                                              +5                    @106C
   SM126G0 126
                                  105         2.0                5.0            SM126G0                                                           0
                   125
                                  104         1.0                4.0                                                                              5

                   112            106         3.0                6.0                                                                              +5                    @90C
   SM110G0 111
                                  105         2.0                5.0            SM110G0                                                           0
                   110
                                  104         1.0                4.0                                                                              5

                     99           106         3.0                13.0                                                                             +5                    @75C
   SM095G0 98
                                  105         2.0                11.0           SM095G0                                                           0
                     97
                                  104         1.0                9.0                                                                              5

     Part    Operating          Insulation    Withstand Voltage     Internal      Part    Change of 0 10                                                  100  1,000     10,000
   Number  Temperature      Resistance after    after Operation   Resistance    Number
                                                       (kV)      (m/25 mm)                Operating                                                       Time (Hours)
                 (C)           Operation                                                Temperature
                                  (M)
                                                                                               (C)

4
                                                   SM/G SERIES

Cautions

This section describes cautions designed to protect the performance of the thermal cutoff, Be sure to read and
fully understand these cautions.

   To obtain full performance from the thermal cutoff, it is necessary for the customer to appropriately store
   the thermal cutoff, design appropriate circuits for the application, and perform evaluations, mounting and
   testing as necessary. Problems arising from the inappropriate execution of the above are the responsibility
   of the customer, and NEC declines any and all responsibility.

Design Cautions
q Do not use this device for any purpose other than as a thermal cutoff.

   The thermal cutoff is designed to detect abnormal rises in temperature and break circuits if needed. It is not
   a current fuse that cuts excess current. If used as a current fuse, the SEFUSE may malfunction.

q Do not use this device in aerospace equipment, aeronautical equipment, nuclear reactor control systems, Iife
   support equipment or systems, transportation machinery engine control or safety-related equipment.
   This device is designed for use in household electric appliance, office automation equipment, audio and video
   equipment, computer and communications equipment, test and measurement equipment, personal electronic
   equipment and transportation equipment (excluding engine control).

q The customer should select the proper thermal cutoff device, mounting location, and mounting method as
   appropriate for each application.
   Verify whether the chosen selections are appropriate by repeatedly testing the final design for thermal cutoff
   under normal conditions as well as under predicted maximum abnormal conditions.

q Make designs so that the temperature of the body of the thermal cutoff does not exceed the temperatures
   shown in Table 1.
   If, these temperatures are exceeded on a regular basis, the thermal cutoff may start operating only at tem-
   peratures lower than the normal operating temperature. Malfunctions may also occur. Even if the thermal
   cutoff's operating temperature is exceeded, it may malfunction.

Table 1. Recommended maximum body temperature on a reqular basis

Part Number              Pass-through Current
                     to 2 A to 3 A to 4 A
             to 1 A                            to 5 A

SM095G       75C    70C   65C   --          --

SM110G       90C    85C   85C   80C        75C

SM126G       106C   106C  100C  95C        90C

SM130G       110C   110C  105C  100C       95C

SM134G       114C   114C  110C  105C 100C

SM145G       125C   125C  120C  120C 115C

1) : The temperature does not means ambient temperature but surface temperature on
      thermal cutoff.

2) : When a large current flows through a thermal cutoff, temperature difference occurs
      between the case and the lead. Therefore, it is recommended to measure some points
      on the thermal cutoff, and make design so that the highest temperature does not exceed
      the temperature shown in Table 1.

                                                                                                                   5
   SM/G SERIES

    q The body temperature of the thermal cutoff becomes higher as current passes through and might rise higher
        than the ambient operating temperature (see test data). The temperature may rise even higher depending on
        the mounting method and other conditions. Therefore, after mounting the thermal cutoff under the same
        conditions you would use for the actual application, work the final product and measure the body temperature
        of the thermal cutoff.

    q Use the thermal cutoff with a voltage and current level lower than the rated level.
        If the thermal cutoff is used with a voltage or current level higher than the rated level, the body of the thermal
        cutoff may be destroyed.

    q Do not use the thermal cutoff in water, organic solvents or other liquids, or environments containing sulfurous
        acid gas, nitrous acid gas, or high humidity. Doing so will cause deterioration of the sealing resin, the thermal
        cutoff may operate at lower than operating temperatures, or any other malfunctions may occur. Also, the
        thermal cutoff may not operate even if its operating temperature is exceeded.

    Lead wire process
    q When bending the lead wire, in order to protect the resin seal from excessive pressure, secure the lead wire

        cIose to the case and bend the part beyond the secured section,

                                                                                                                          3 mm or more

               ,,,,,,
   ,,,,,,
   ,,,,,,,
               ,,,,,,,
   Secured              Secured

      The lead wire should be bent at a distance 3 mm or more from the body of the fuse, and should not be twisted.
   q The tensile strength applied to the lead wire should be 1kg or less for the SM type thermal cutoff.
   q The strength applied to the body of the thermal cutoff should be 5 kg or less for the SM type thermal cutoff.

            5 kgf max.

                         0.8 steel wire

   Mounting
      SEFUSE can be mounted by soldering, caulking, or welding.

   q If soldering, note that the thermal cutoff may not function because of excessive solder temperature.
      To prevent such malfunctions, for example, holding the lead near the case by a tool is effective for allowing
      the heat to escape, and the soldering should be done in short interval.
      Another effective method is to use a lower solder temperature and to solder at a location that is distant from
      the case.

6
                                                                             SM/G SERIES

q If caulking or welding, be careful to keep the resistance value of the connecting section low.
   If the connecting section has a high resistance value, the passing current may generate an abnormally high
   temperature that will cause the thermal cutoff to operate (break the circuit).

q It is recommended that the connecting position at the lead of resign-sealed side should be 5 mm or more from
   the body of the thermal cutoff.

5 mm or more  5 mm or more Position of installation

q After mounting the thermal cutoff, be careful not to apply force that may pull, push or twist the lead wires.

Recommendation
q Be careful when mounting the thermal cutoff because external force, heat, or a harmful atmosphere (contain-

   ing excessive humidity or sulfurous acid gas) may damage the characteristics of the thermal cutoff. If appli-
   cable, it is recommended to warn general consumers who are not aware of the usage cautions for the thermal
   cutoff not to mount, remove or replace the thermal cutoff through a note to this effect in the user's manual and
   other related material.

If you desire any clarifications or explanations regarding these cautions, please call an NEC sales
representative.

The values contained in this document were obtained under certain testing conditions at NEC. They are not
guaranteed and are for reference only.

                                                                                                                     7
SM/G SERIES

       No part of this document may be copied or reproduced in any form or by any means without the prior
       written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which
       may appear in this document.
       NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellec-
       tual property rights of third parties by or arising from use of a device described herein or any other
       liability arising from use of such device. No license, either express, implied or otherwise, is granted
       under any patents, copyrights or other intellectual property rights of NEC Corporation or others.
       While NEC Corporation has been making continuous effort to enhance the reliability of its electronic
       components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or
       injury to persons or property arising from a defect in an NEC electronic component, customers must
       incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-
       failure features.
       NEC devices are classified into the following three quality grades:
       "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based
       on a customer designated "quality assurance program" for a specific application. The recommended
       applications of a device depend on its quality grade, as indicated below. Customers must check the
       quality grade of each device before using it in a particular application.

           Standard: Computers, office equipment, communications equipment, test and measurement equipment, au-
                         dio and visual equipment, home electronic appliances, machine tools, personal electronic equip-
                         ment and industrial robots

           Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
                         systems, anti-crime systems, safety equipment and medical equipment (not specifically de-
                         signed for life support)

           Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
                         support systems or medical equipment for life support, etc.

       The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
       If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
       they should contact an NEC sales representative in advance.
       Anti-radioactive design is not implemented in this product.
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved