电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

SL2S5402FUD,003

器件型号:SL2S5402FUD,003
器件类别:热门应用    无线/射频/通信   
厂商名称:NXP
厂商官网:https://www.nxp.com
标准:
下载文档

器件描述

RFID Transponders ICODE SLIX-S

参数
产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
NXP
产品种类:
Product Category:
RFID Transponders
RoHS:YES
封装:
Packaging:
Bulk
商标:
Brand:
NXP Semiconductors
产品类型:
Product Type:
RFID Transponders
工厂包装数量:
Factory Pack Quantity:
80000
子类别:
Subcategory:
Wireless & RF Integrated Circuits
单位重量:
Unit Weight:
0.000003 oz

SL2S5402FUD,003器件文档内容

            SL2S5302; SL2S5402

            ICODE SLIX-S

            Rev. 3.2 — 27 August 2012                                  Product data sheet

            192132                                                     COMPANY PUBLIC

1.  General description

         The ICODE SLIX-S IC is a dedicated chip for smart label applications with the need for a

         higher security level, larger memory and/or a product which takes care of the increasing

         demand for perfect customer privacy. This IC is the third generation of a product family of

         smart label ICs based on the ISO standards ISO/IEC 15693 (Ref. 1) and ISO/IEC 18000-3

         (Ref. 4), prolonging a successful story of NXP in the field of vicinity identification systems.

         The ICODE system offers the possibility of operating labels simultaneously in the field of

         the reader antenna (anticollision). It is designed for long range applications.

    1.1  Contactless energy and data transfer

         Whenever connected to a very simple and easy-to-produce type of antenna (as a result of

         the 13.56 MHz carrier frequency) made out of a few windings printed, winded, etched or

         punched coil, the ICODE SLIX-S IC can be operated without line of sight up to a distance

         of 1.5 m (gate width). No battery is needed. When the smart label is positioned in the field

         of an interrogator antenna, the high speed RF communication interface enables data to be

         transmitted up to 53 kbit/s.

    1.2  Anticollision

         An intelligent anticollision function enables several tags to operate in the field

         simultaneously. The anticollision algorithm selects each tag individually and ensures that

         the execution of a transaction with a selected tag is performed correctly without data

         corruption resulting from other tags in the field.

    1.3  Security and privacy aspects

         •  Unique IDentifier (UID):

            The UID cannot be altered and guarantees the uniqueness of each label.

         •  Password protected memory management (Read/Write access):

            Pages (1 page = 4 blocks of 4 bytes each) can be protected with a password, which

            ensures that only authorized users get read/write access to the protected parts of the

            user memory (anti counterfeiting).

         •  Password protected Label Destroy:

            The 32-bit Destroy password enables an addressed label to be destroyed with the

            DESTROY SLIX-S command. That status is irreversible and the label will never

            respond to any command again.

         •  Password protected Privacy Mode:
NXP Semiconductors                                                         SL2S5302; SL2S5402

                                                                                                                  ICODE SLIX-S

                            The 32-bit Privacy password enables a label to be set to the Privacy mode with the

                            ENABLE PRIVACY command. In this mode the label will not respond to any

                            command except the command GET RANDOM NUMBER, until it next receives the

                            correct Privacy password. This mode is especially designed to meet the increasing

                            demand to take care of the customers privacy.

                         •  Password protected EAS and AFI functionality:

                            The 32-bit EAS/AFI password enables the addressed label to be set in a mode where

                            the EAS status, the EAS ID and/or the AFI value can only be changed if the correct

                            EAS/AFI password is transmitted to the label within the mentioned commands.

2.  Features        and     benefits

                    2.1  ICODE SLIX-S RF interface (ISO/IEC 15693)

                           Contactless transmission of data and supply energy (no battery needed)

                           Operating distance: up to 1.5 m (depending on antenna geometry)

                           Operating frequency: 13.56 MHz (ISM, world-wide licence freely available)

                           Fast data transfer: up to 53 kbit/s

                           High data integrity: 16-bit CRC, framing

                           True anticollision

                           Electronic Article Surveillance (EAS)

                           Application Family Identifier (AFI) supported

                           Data Storage Format Identifier (DSFID)

                           ENABLE PRIVACY command with 32-bit Privacy password

                           DESTROY SLIX-S command with 32-bit Destroy password

                           Additional fast anticollision read

                           Write distance equal to read distance

                    2.2  EEPROM

                           2048 bits (2 KB), organized in 64 blocks of 4 bytes each, 4 blocks are summed up to

                            1 page

                           50 years data retention

                           Write endurance of 100000 cycles

                    2.3  Security

                           Unique identifier for each device

                           Lock mechanism for each user memory block (write protection)

                           Lock mechanism for DSFID, AFI, EAS

                           Password (32-bit) protected memory management for Read access

                           Password (32-bit) protected memory management for Write access

                           Password (32-bit) protected Label Destroy

                           Password (32-bit) protected Privacy Mode

                           Password (32-bit) protected EAS and AFI functionality

SL2S5302_SL2S5402                     All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                              Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                       192132                                                       2 of 35
NXP Semiconductors                                                    SL2S5302; SL2S5402

                                                                                                                      ICODE SLIX-S

3.  Applications

                      Libraries

                      Item level tagging in pharmaceutical supply chains

                      Counterfeit protection for consumer goods

                      Industrial applications

                      Asset and document tracking

4.  Ordering information

                    Table 1.    Ordering information

                    Type number      Package                                                                                     Version

                                     Name                Description

                    SL2S5302FUD      wafer               sawn, bumped wafer, 120 m, on film frame                    carrier,   -

                                                         Ci between LA and LB = 23.5 pF (typical)

                    SL2S5402FUD      wafer               sawn, bumped wafer, 120 m, on film frame                    carrier,   -

                                                         Ci between LA and LB = 97 pF (typical)

5.  Block diagram

                                           ANALOG                     DIGITAL CONTROL                                 EEPROM

                                     RF INTERFACE

                                                    VREG

                                     PAD

                                                           VDD        ANTICOLLISION

                                     LA

                                     RECT       DEMOD                 READ/WRITE

                                                           data       CONTROL

                                                                 in

                       ANTENNA                                        ACCESS CONTROL                                  MEMORY

                                     Cres           MOD

                                                           data

                                                                 out

                                                                      EEPROM INTERFACE                           R/W

                                                                      CONTROL

                                                    CLK

                                     PAD

                                                           Clock      RF INTERFACE

                                                                      CONTROL                                         SEQUENCER

                                     LB                                                                               CHARGE PUMP

                                                                                                                                001aam247

                    Fig 1.    Block  diagram    of  ICODE  SLIX-S

SL2S5302_SL2S5402                    All information provided in this document is subject to legal disclaimers.       © NXP B.V. 2012. All rights reserved.

Product data sheet                         Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                           192132                                                                     3 of 35
NXP Semiconductors                                            SL2S5302; SL2S5402

                                                                                                                                        ICODE SLIX-S

6.  Pinning information

                                                        LA                                                     LB

                                                GND           TEST

                                                            not to scale                                                     001aam246

                    Fig 2.  Wafer  SL2S5302FUD  layout and  pin configuration                                      for  the  bare die

SL2S5302_SL2S5402                  All information provided in this document is subject to legal disclaimers.                © NXP      B.V.  2012.  All  rights reserved.

Product data sheet                 Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                  192132                                                                                                    4 of 35
NXP Semiconductors                                                   SL2S5302; SL2S5402

                                                                                                                                        ICODE SLIX-S

                                                            LA                                                 LB

                                                            GND      TEST

                                                                 not to scale                                                001aam546

                         Fig 3.    Wafer SL2S5402FUD layout and  pin configuration                                 for  the  bare die

                    6.1  Pin description

                         Table 2.  Bonding pad description

                         Symbol           Description

                         LA               antenna RF input

                         LB               antenna RF input

                         GND              ground

                         TEST             test input

SL2S5302_SL2S5402                  All information provided in this document is subject to legal disclaimers.                © NXP      B.V.  2012.  All  rights reserved.

Product data sheet                        Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                    192132                                                                                                  5 of 35
NXP Semiconductors                                                           SL2S5302; SL2S5402

                                                                                                                                       ICODE SLIX-S

7.  Mechanical specification

                    7.1  Wafer specification

                         See Ref. 6 “General specification for 8” wafer on UV-tape with electronic fail die marking”.

                         Table 3.     Wafer  specification

                         Wafer

                         Designation                        each wafer is enscribed with                                batch  number  and  wafer  number

                         Diameter                           200 mm (8 inches)

                         Thickness                          120 m  15 m

                         Process                            CMOS 0.14 m

                         Batch size                         25 wafers

                         Dies per wafer

                         SL2S5302FUD                        110050

                         SL2S5402FUD                        88225

                         Wafer backside

                         Material                           Si

                         Treatment                          ground and stress release

                         Roughness                          Ra minimum = 0.5 m

                                                            Rt maximum = 5 m

                         Chip dimensions

                         Die size without scribe

                         SL2S5302FUD                        520 m  484 m = 251680 mm2

                         SL2S5402FUD                        520 m  607 m = 315640 mm2

                         Scribe line width

                         X-dimension                        15 m (scribe line width measured between                                  nitride  edges)

                         Y-dimension                        15 m (scribe line width measured between                                  nitride  edges)

                         Number of pads                     4

                         Pad location                       non-diagonal/placed in chip corners

                         Distance pad to pad LA   to  LB    400 m

                         Distance pad to pad LB   to  TEST

                         SL2S5302FUD                        360 m

                         SL2S5402FUD                        517 m

                         Passivation on front

                         Type                               sandwich structure

                         Material                           PE-nitride (on top)

                         Thickness                          1.75 m total thickness of passivation

                         Au bump

                         Material                           >99.9 % pure Au

                         Hardness                           35 HV to 80 HV 0.005

                         Shear strength                     >70 MPa

                         Height                             18 m

SL2S5302_SL2S5402                           All information provided in this document is subject to legal disclaimers.         © NXP B.V. 2012. All rights reserved.

Product data sheet                                Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                              192132                                                                                 6 of 35
NXP  Semiconductors                                                     SL2S5302; SL2S5402

                                                                                                                         ICODE SLIX-S

                          Table 3.   Wafer specification

                          Height uniformity

                          within a die                    2 m

                          within a wafer                  3 m

                          wafer to wafer                  4 m

                          Bump flatness                   1.5 m

                          Bump size

                          LA, LB                          60 m  60 m

                          TEST, GND                       60 m  60 m

                          variation                       5 m

                          Under bump metallization        sputtered TiW

                   7.1.1  Fail die identification

                          No inkdots are applied to the wafer.

                          Electronic wafer mapping (SECS II format) covers the electrical test results and

                          additionally the results of mechanical/visual inspection.

                          See Ref. 6 “General specification for 8” wafer on UV-tape with electronic fail die             marking”.

                   7.1.2  Map file distribution

                          See Ref. 6 “General specification for 8” wafer on UV-tape with electronic fail die             marking”.

SL2S5302_SL2S5402                            All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                           Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                            192132                                                         7 of 35
NXP Semiconductors                                                         SL2S5302; SL2S5402

                                                                                                                ICODE SLIX-S

8.  Functional           description

                    8.1  Block description

                         The ICODE SLIX-S IC consists of three major blocks:

                         •  Analog RF interface

                         •  Digital controller

                         •  EEPROM

                         The analog section provides stable supply voltage and demodulates data received from

                         the reader for processing by the digital section. The analog section’s modulation transistor

                         also transmits data back to the reader.

                         The digital section includes the state machines, processes the protocol and handles

                         communication with the EEPROM.

                         The label requires no internal power supply. Its contactless interface generates the power

                         supply and the system clock via the resonant circuitry by inductive coupling to the

                         interrogator. The interface also demodulates data that are transmitted from the

                         interrogator to the ICODE Label, and modulates the electromagnetic field for data

                         transmission from the ICODE Label to the interrogator.

                         Data are stored in a non-volatile memory (EEPROM).

                    8.2  Memory organization

                         The 2048 bit EEPROM memory is divided into 64 blocks. A block is the smallest access

                         unit. Each block consists of 4 bytes (1 block = 32 bits). 4 blocks are summed up to 1 page

                         for password protection. Bit 0 in each byte represents the least significant bit (LSB) and

                         bit 7 the most significant bit (MSB), respectively.

                         The memory is divided into 2 parts:

                         •  Configuration area

                            –  Within this part of the memory all required information is stored, such as UID, write

                               protection, access control information, passwords, AFI and EAS. This memory

                               area cannot be directly accessed.

                         •  User memory

                            –  Within the 1280 bit memory area the user data are stored. Direct read/write access

                               to this part of the memory is possible depending on the related security and write

                               protection conditions.

SL2S5302_SL2S5402                   All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                              Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                         192132                                                        8 of 35
NXP Semiconductors                                                               SL2S5302; SL2S5402

                                                                                                                                            ICODE SLIX-S

                          Table 4.     Memory         organization

                          Page             Block      Byte 0        Byte  1      Byte 2                                    Byte 3    Description

                                                                                                                                     Configuration area for

                                                                                                                                     internal use

                          0                0                                                                                         User memory:

                                           1                                                                                         10 pages,

                                           2                                                                                         4 blocks each,

                                           3                                                                                         4 bytes each,

                          :                :          :             :            :                                         :         160 bytes in total.

                          9                36

                                           37

                                           38

                                           39

                          Blocks 0     to  39  can    be addressed  with  read  and write                                  commands  only.

                   8.2.1  Unique identifier

                          The 64-bit unique identifier (UID) is programmed during the production process according

                          to ISO/IEC 15693-3 and cannot be changed afterwards.

                          The 64 bits are numbered according to ISO/IEC 15693-3 starting with LSB 1 and ending

                          with MSB 64. This is in contrast to the general used bit numbering within a byte.

                          The TAG type is a part of the UID (bit 41 to 48, next to the manufacturer code which is

                          “04h” for NXP Semiconductors).

                          The TAG type of the ICODE SLIX-S IC is “02h”.

                          Bit 37 is set to logic 1 for the ICODE SLIX-S IC which indicates that this type supports the

                          password protected AFI feature (not supported by ICODE SLI-S with bit 37 set to logic 0).

                          Table 5.     Unique identifier

                                MSB                                                                                                                  LSB

                                64:57          56:49     48:41                                                                40:1

                                “E0”           “04”      “02”                       IC manufacturer serial number

                                UID 7          UID 6     UID 5          UID 4       UID 3                                     UID 2         UID 1    UID 0

                   8.2.2  Configuration of delivered ICs

                          ICODE SLIX-S ICs are delivered with the following configuration by NXP Semiconductors:

                             •  Unique identifier is unique and read only

                             •  Write access conditions allow change to user blocks, AFI, DSFID, EAS and

                                passwords

                             •  All password bytes are 00h for the read and write protection password and the

                                EAS/AFI password

                             •  All password bytes are 0Fh for the Privacy and Destroy passwords

                             •  User data memory is not password protected

                             •  Password protected Privacy Mode is disabled

SL2S5302_SL2S5402                              All information provided in this document is subject to legal disclaimers.                   © NXP B.V. 2012. All rights reserved.

Product data sheet                                    Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                  192132                                                                                    9 of 35
NXP  Semiconductors                                                           SL2S5302; SL2S5402

                                                                                                                    ICODE SLIX-S

                            •  EAS and AFI password protection is disabled

                            •  Status of EAS mode is not defined

                            •  AFI is supported and not defined

                            •  DSFID is supported and not defined

                            •  User data memory is not defined

                            Remark: Because the EAS mode is undefined at delivery, the EAS mode shall be set

                            (enabled or disabled) according to your application requirements during the test or

                            initialization phase.

                            Remark: If password protection is not required, depending on the targeted application, it

                            is recommended to write random passwords during the label initialization.

                    8.3     Communication principle

                            For detailed description of the protocol and timing please refer to ISO/IEC 15693-2

                            (modulation, bit-coding, framing, Ref. 2) and ISO/IEC 15693-3 (anticollision, timing,

                            protocol, Ref. 3).

                    8.4     Supported commands

                   8.4.1    Mandatory commands

                   8.4.1.1  INVENTORY

                            As defined in ISO/IEC 15693-3.

                            Exception: If the Privacy or Destroy mode is enabled the label will not respond.

                   8.4.1.2  STAY QUIET

                            As defined in ISO/IEC 15693-3.

                   8.4.2    Optional commands

                   8.4.2.1  READ SINGLE BLOCK

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

                            If the related page of the addressed block is protected with the Read-Password and the

                            password has not been transmitted first with the SET PASSWORD command the label will

                            respond according to the error handling (see Section 8.5 “Error handling”).

                   8.4.2.2  WRITE SINGLE BLOCK

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

SL2S5302_SL2S5402                       All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                                 Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                              192132                                                  10 of 35
NXP Semiconductors                                                        SL2S5302; SL2S5402

                                                                                                                     ICODE SLIX-S

                            If the addressed block is part of a write protected page or only protected with the Read

                            Password (see Section 8.4.3.6 “PROTECT PAGE”) and the password has not been

                            transmitted first with the SET PASSWORD command the label will respond according to

                            the error handling (see Section 8.5 “Error handling”).

                   8.4.2.3  LOCK BLOCK

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

                            If the addressed block is part of a write protected page or only protected with the read

                            password (see Section 8.4.3.6 “PROTECT PAGE”) and the password has not been

                            transmitted first with the SET PASSWORD command, the label will respond according to

                            the error handling (see Section 8.5 “Error handling”).

                   8.4.2.4  SELECT

                            As defined in ISO/IEC 15693-3.

                   8.4.2.5  RESET TO READY

                            As defined in ISO/IEC 15693-3.

                   8.4.2.6  WRITE AFI

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

                            Remark: This command maybe password protected, refer to Section 8.4.3.17

                            “PASSWORD PROTECT EAS/AFI”.

                   8.4.2.7  LOCK AFI

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

                            Remark: This command maybe password protected, refer to Section 8.4.3.17

                            “PASSWORD PROTECT EAS/AFI”.

                   8.4.2.8  WRITE DSFID

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

                   8.4.2.9  LOCK DSFID

                            As defined in ISO/IEC 15693-3.

                            Option 0 (Option flag not set) is supported.

SL2S5302_SL2S5402                        All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                          Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                              192132                                                    11 of 35
NXP Semiconductors                                                                 SL2S5302; SL2S5402

                                                                                                                                            ICODE SLIX-S

                             Option 1 (Option flag set) is supported.

                   8.4.2.10  GET SYSTEM INFORMATION

                             As defined in ISO/IEC 15693-3.

                             The TAG type of the ICODE SLIX-S IC is “02h”.

                   8.4.3     Custom commands

                             The manufacturer code of NXP Semiconductors is defined in ISO/IEC 7816-6A1 (Ref. 5).

                             It has the value “04h”.

                             For the structure of custom commands please refer to ISO/IEC 15693-3.

                             If not explicitly specified differently all address modes are supported.

                   8.4.3.1   GET RANDOM NUMBER

                             Command code = B2h

                             The GET RANDOM NUMBER command is required to receive a random number from the

                             label IC. The passwords that will be transmitted with the SET PASSWORD command

                             have to be calculated with the password and the random number (see Section 8.4.3.2

                             “SET PASSWORD”).

                             The different passwords are addressed with the password identifier.

                             Table 6.  Request format

                             SOF          Flags           GET             IC Mfg                                      UID       CRC16         EOF

                                                          RANDOM          code

                                                          NUMBER

                             -            8 bits          8 bits          8 bits                                      64 bits   16 bits       -

                                                                                                                      optional

                             Table 7.  Response format when Error_flag set

                             SOF                  Flags                   Error code                                  CRC16              EOF

                             -                    8 bits                  8 bits                                      16 bits            -

                             Table 8.  Response format when Error_flag NOT set

                             SOF                  Flags                   Random number                               CRC16              EOF

                             -                    8 bits                  16 bits                                     16 bits            -

                   8.4.3.2   SET PASSWORD

                             Command code = B3h

                             The SET PASSWORD command enables the different passwords to be transmitted to the

                             label to access the different protected functionalities of the following commands. The SET

                             PASSWORD command has to be executed just once for the related passwords if the label

                             is powered.

                             Remark: The SET PASSWORD command can only be executed in Addressed or

                             Selected mode except for the Privacy password. If the Privacy password is transmitted

                             (see Section 8.4.3.10 “ENABLE PRIVACY”), the timing of the SET PASSWORD

                             command is write alike.

SL2S5302_SL2S5402                         All information provided in this document is subject to legal disclaimers.                     © NXP B.V. 2012. All rights reserved.

Product data sheet                                    Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                    192132                                                                           12 of 35
NXP Semiconductors                                                               SL2S5302; SL2S5402

                                                                                                                                                   ICODE SLIX-S

                            The XOR password has to be calculated with the password and two times the received

                            random number from the last GET RANDOM NUMBER command:

                            XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],

                            Random_Number[15:0]}.

                            The different passwords are addressed with the password identifier.

                            Table 9.   Request format

                            SOF       Flags   SET             IC Mfg          UID                                         Password    XOR          CRC16    EOF

                                              PASSWORD        code                                                        identifier  password

                            -         8 bits  8 bits          8 bits          64 bits                                     8 bits      32 bits      16 bits  -

                                                                              optional

                            Table 10.  Password Identifier

                            Password identifier                                  Password

                            01h                                                  Read

                            02h                                                  Write

                            04h                                                  Privacy

                            08h                                                  Destroy SLIX-S

                            10h                                                  EAS/AFI

                            Table 11.  Response format when Error_flag set

                            SOF                  Flags                Error code                                          CRC16                 EOF

                            -                    8 bits               8 bits                                              16 bits               -

                            Table 12.  Response format when Error_flag NOT set

                            SOF                       Flags                      CRC16                                                     EOF

                            -                         8 bits                     16 bits                                                   -

                            Remark: If the IC receives an invalid password, it will not execute any following command

                            until a Power-On Reset (POR) (RF reset) is executed.

                   8.4.3.3  WRITE PASSWORD

                            Command code = B4h

                            The WRITE PASSWORD command enables a new password to be written into the related

                            memory if the related old password has already been transmitted with a SET PASSWORD

                            command and the addressed password is not locked (see Section 8.4.3.4 “LOCK

                            PASSWORD”).

                            Remark:    The WRITE PASSWORD command can only be executed in addressed or

                            selected mode. The new password takes effect immediately which means that the new

                            password has to be transmitted with the SET PASSWORD command to access protected

                            blocks/pages.

                            The different passwords are addressed with the password identifier.

                            The timing of the command is write alike.

                            Option 0 (Option flag not set) is supported.

SL2S5302_SL2S5402                             All information provided in this document is subject to legal disclaimers.                       © NXP B.V. 2012. All rights reserved.

Product data sheet                                    Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                192132                                                                                        13 of 35
NXP  Semiconductors                                                               SL2S5302; SL2S5402

                                                                                                                                                     ICODE SLIX-S

                            Option 1 (Option flag set) is      supported.

                            Table 13.  Request format

                            SOF  Flags         WRITE           IC Mfg      UID          Password                                    Password         CRC16    EOF

                                               PASSWORD        code                     identifier

                            -    8 bits        8 bits          8 bits      64 bits      8 bits                                      32 bits          16 bits  -

                                                                           optional

                            Table 14.  Password Identifier

                            Password identifier                                   Password

                            01h                                                   Read

                            02h                                                   Write

                            04h                                                   Privacy

                            08h                                                   Destroy SLIX-S

                            10h                                                   EAS/AFI

                            Table 15.  Response format when Error_flag set

                            SOF                  Flags                 Error code                                          CRC16                  EOF

                            -                    8 bits                8 bits                                              16 bits                -

                            Table 16.  Response format when Error_flag NOT set

                            SOF                        Flags                      CRC16                                                      EOF

                            -                          8 bits                     16 bits                                                    -

                   8.4.3.4  LOCK PASSWORD

                            Command code = B5h

                            The LOCK PASSWORD command enables the addressed password to be locked if the

                            related password has already been transmitted with a SET PASSWORD command. A

                            locked password cannot be changed.

                            The different passwords are addressed with the password identifier.

                            The timing of the command is write alike.

                            Option 0 (Option flag not set) is supported.

                            Option 1 (Option flag set) is supported.

                            Table 17.  Request format

                            SOF        Flags   LOCK            IC Mfg          UID                                         Password    CRC16           EOF

                                               PASSWORD        code                                                        identifier

                            -          8 bits  8 bits          8 bits          64 bits                                     8 bits      16 bits         -

                                                                               optional

SL2S5302_SL2S5402                              All information provided in this document is subject to legal disclaimers.                       © NXP B.V. 2012. All rights reserved.

Product data sheet                                     Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                 192132                                                                                         14 of 35
NXP Semiconductors                                                               SL2S5302; SL2S5402

                                                                                                                                         ICODE SLIX-S

                            Table 18.  Password identifier

                            Password identifier                                  Password

                            01h                                                  Read

                            02h                                                  Write

                            04h                                                  Privacy

                            08h                                                  Destroy SLIX-S

                            10h                                                  EAS/AFI

                            Table 19.  Response format when Error_flag set

                            SOF                  Flags                   Error code                                CRC16              EOF

                            -                    8 bits                  8 bits                                    16 bits            -

                            Table 20.  Response format when Error_flag NOT set

                            SOF                  Flags                           CRC16                                       EOF

                            -                    8 bits                          16 bits                                     -

                   8.4.3.5  64 BIT PASSWORD PROTECTION

                            Command code = BBh

                            The 64-bit PASSWORD PROTECTION command enables the Label IC to be instructed

                            that both of the Read and Write passwords are required to get access to password

                            protected blocks (pages). This mode can be enabled if the Read and Write passwords

                            have been transmitted first with a SET PASSWORD command.

                            If the 64-bit password protection is enabled, both passwords are required for read & write

                            access to protected blocks (pages).

                            Once the 64 bit password protection is enabled, a change back to 32-bit password

                            protection (read and write password) is not possible.

                            Remark: A retransmission of the passwords is not required after the execution of the

                            64-bit PASSWORD PROTECT EAS/AFI command.

                            The timing of the command is write alike.

                            Table 21.  Request format

                            SOF        Flags             64 BIT          IC Mfg code                               UID       CRC16         EOF

                                                         PASSWORD

                                                         PROTECTION

                            -          8 bits            8 bits          8 bits                                    64 bits   16 bits       -

                                                                                                                   optional

                            Table 22.  Response format when Error_flag set

                            SOF                  Flags                   Error code                                CRC16              EOF

                            -                    8 bits                  8 bits                                    16 bits            -

                            Table 23.  Response format when Error_flag NOT set

                            SOF                  Flags                           CRC16                                       EOF

                            -                    8 bits                          16 bits                                     -

SL2S5302_SL2S5402                      All information provided in this document is subject to legal disclaimers.               © NXP B.V. 2012. All rights reserved.

Product data sheet                               Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                   192132                                                                         15 of 35
NXP  Semiconductors                                                       SL2S5302; SL2S5402

                                                                                                                                                    ICODE SLIX-S

                   8.4.3.6  PROTECT PAGE

                            Command code = B6h

                            The PROTECT PAGE command enables the page protection condition to be changed

                            under the following circumstances:

                               •  The related passwords (Read and/or Write password) have been transmitted first with

                                  the SET PASSWORD command. If the 64-bit PASSWORD PROTECT EAS/AFI is

                                  enabled, the Read and Write passwords have to be transmitted first.

                               •  The addressed page protection condition is not locked (see Section 8.4.3.7 “LOCK

                                  PAGE PROTECTION CONDITION” on page 16

                            The timing of the command is write alike.

                            Table 24.  Request format

                            SOF        Flags   PROTECT    IC Mfg          UID                                              Page     Protectio    CRC16    EOF

                                               PAGE       code                                                             number   n status

                            -          8 bits  8 bits     8 bits          64 bits                                          8 bits   8 bits       16 bits  -

                                                                          optional

                            Table 25.  Protection status

                            Protection status  32 bit password protection                                                  64 bit password protection

                            00h                Public                                                                      Public

                            01h                Read and Write protected by the                                             Read and Write protected by the

                                               Read password                                                               Read plus Write password

                            10h                Write protected by the Write                                                Write protected by the Read plus

                                               password                                                                    Write password

                            11h                Read protected by the Read                                                  Read and Write protected by the

                                               password and Write protected by the                                         Read plus Write password

                                               Write password

                            Table 26.  Response format when Error_flag set

                            SOF                Flags              Error code                                               CRC16                 EOF

                            -                  8 bits             8 bits                                                   16 bits               -

                            Table 27.  Response format when Error_flag NOT set

                            SOF                 Flags                          CRC16                                                        EOF

                            -                   8 bits                         16 bits                                                      -

                   8.4.3.7  LOCK PAGE PROTECTION CONDITION

                            Command code = B7h

                            The LOCK PAGE PROTECTION CONDITION command enables the status of the page

                            protection condition of the related page to be locked if the Read and Write passwords

                            have been transmitted first with the SET PASSWORD command.

                            The timing of the command is write alike.

SL2S5302_SL2S5402                              All information provided in this document is subject to legal disclaimers.                      © NXP B.V. 2012. All rights reserved.

Product data sheet                             Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                            192132                                                                                             16 of 35
NXP  Semiconductors                                                            SL2S5302; SL2S5402

                                                                                                                                                       ICODE SLIX-S

                            Table 28.  Request format

                            SOF        Flags      LOCK PAGE     IC Mfg              UID                                            Page            CRC16        EOF

                                                  PROTECTION    code                                                               number

                                                  CONDITION

                            -          8 bits     8 bits        8 bits              64 bits                                        8 bits          16 bits      -

                                                                                    optional

                            Table 29.  Response format when Error_flag set

                            SOF                Flags                   Error code                                          CRC16                    EOF

                            -                  8 bits                  8 bits                                              16 bits                  -

                            Table 30.  Response format when Error_flag NOT set

                            SOF                        Flags                   CRC16                                                           EOF

                            -                          8 bits                  16 bits                                                         -

                   8.4.3.8  GET MULTIPLE BLOCK PROTECTION STATUS

                            Command code = B8h

                            The GET MULTIPLE BLOCK PROTECTION STATUS command requests the label to

                            respond with the block protection status of the requested blocks.

                            The number of blocks in the request is one less than the number of blocks that the ICODE

                            SLIX-S IC returns in its response.

                            Remark: If the sum of the first block number and the number of blocks exceeds the total

                            available number of user blocks, the number of transmitted security status bytes is less

                            than the requested number, which means that the last returned status byte is the one

                            corresponding to the highest available user block, followed by the 16-bit CRC and the

                            EOF.

                            Table 31.  Request format

                            SOF   Flags   GET MULTIPLE          IC Mfg         UID                                         First           Number      CRC16       EOF

                                          BLOCK                 code                                                       block           of

                                          PROTECTION                                                                       number          blocks

                                          STATUS

                            -     8 bits  8 bits                8 bits         64 bits                                     8 bits          8 bits      16 bits     -

                                                                               optional

                            Table 32.  Response format when Error_flag set

                            SOF                Flags                   Error code                                          CRC16                    EOF

                            -                  8 bits                  8 bits                                              16 bits                  -

                            Table 33.  Response format when Error_flag NOT set

                            SOF                Flags            Block protection                                           CRC16                    EOF

                                                                status

                            -                  8 bits           8 bits                                                     16 bits                  -

                                                                Repeated as needed

SL2S5302_SL2S5402                              All information provided in this document is subject to legal disclaimers.                          © NXP B.V. 2012. All rights reserved.

Product data sheet                                Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                 192132                                                                                              17 of 35
NXP  Semiconductors                                                             SL2S5302; SL2S5402

                                                                                                                                           ICODE SLIX-S

                            Table 34.  Block protection status

                            Bit                Name               Value            Description

                            b1 (LSB)           Lock bit (WAC)[1]  0                Block is not locked

                                                                  1                Block is locked (LOCK                          BLOCK    command)

                            b2                 Read password      0                disabled

                                               protected          1                enabled

                            b3                 Write password     0                disabled

                                               protected          1                enabled

                            b4                 Page protection    0                not locked

                                               lock               1                locked

                            b5 to b8 (MSB)     -                  0

                            [1]  WAC: Write Access Condition.

                   8.4.3.9  DESTROY SLIX-S

                            Command code = B9h

                            The DESTROY SLIX-S command enables the ICODE SLIX-S Label IC to be destroyed if

                            the Destroy SLIX-S password is correct. This command is irreversible and the ICODE

                            SLIX-S will never respond to any command again.

                            The DESTROY SLIX-S command can only be executed in addressed or selected mode.

                            The XOR password has to be calculated with the password and two times the received

                            random number from the last GET RANDOM NUMBER command:

                            XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],

                            Random_Number[15:0]}.

                            The timing of the command is write alike.

                            Table 35.  Request format

                            SOF        Flags         DESTROY      IC Mfg        UID                                     XOR       CRC16     EOF

                                                     SLIX-S       code                                                  password

                            -          8 bits        8 bits       8 bits        64 bits                                 32 bits   16 bits   -

                                                                                optional

                            Table 36.  Response format when Error_flag set

                            SOF                Flags                   Error code                                       CRC16          EOF

                            -                  8 bits                  8 bits                                           16 bits        -

                            Table 37.  Response format when Error_flag NOT set

                            SOF                      Flags                      CRC16                                             EOF

                            -                        8 bits                     16 bits                                           -

SL2S5302_SL2S5402                           All information provided in this document is subject to legal disclaimers.               © NXP B.V. 2012. All rights reserved.

Product data sheet                                   Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                 192132                                                                          18 of 35
NXP Semiconductors                                                                   SL2S5302; SL2S5402

                                                                                                                                                ICODE SLIX-S

                   8.4.3.10  ENABLE PRIVACY

                             Command code = BAh

                             The ENABLE PRIVACY command enables the ICODE SLIX-S Label IC to be set to

                             Privacy mode if the Privacy password is correct. The ICODE SLIX-S will not respond to

                             any command except GET RANDOM NUMBER and SET PASSWORD.

                             The XOR password has to be calculated with the password and two times the received

                             random number from the last GET RANDOM NUMBER command:

                             XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],

                             Random_Number[15:0]}.

                             To get out of the Privacy status, the valid Privacy password has to be transmitted to the IC

                             with the SET PASSWORD command.

                             The timing of the command is write alike.

                             Table 38.    Request format

                             SOF          Flags     ENABLE        IC Mfg          UID                                         XOR          CRC16    EOF

                                                    PRIVACY       code                                                        password

                             -            8 bits    8 bits        8 bits          64 bits                                     32 bits      16 bits  -

                                                                                  optional

                             Table 39.    Response format when Error_flag set

                             SOF                  Flags                   Error code                                          CRC16          EOF

                             -                    8 bits                  8 bits                                              16 bits        -

                             Table 40.    Response format when Error_flag NOT set

                             SOF                          Flags                        CRC16                                            EOF

                             -                            8 bits                       16 bits                                          -

                   8.4.3.11  INVENTORY PAGE READ

                             Command code = B0h

                             When receiving the INVENTORY PAGE READ request, the ICODE SLIX-S IC performs

                             the same as the anticollision sequence, with the difference that instead of the UID and the

                             DSFID, the requested memory content is re-transmitted from the ICODE SLIX-S IC.

                             If an error is detected, the ICODE SLIX-S IC remains silent.

                             If the Option flag is set to logic 0, n pages of data including page protection status

                             (password protection condition) are re-transmitted. If the Option flag is set to logic 1,

                             n pages (4 blocks = 16 byte) of data including page protection status (password protection

                             condition) and the part of the UID which is not part of the mask are re-transmitted.

                             The request contains:

                                •  Flags

                                •  INVENTORY PAGE READ command code

                                •  IC manufacturer code

                                •  AFI (if AFI flag set)

SL2S5302_SL2S5402                                 All information provided in this document is subject to legal disclaimers.               © NXP B.V. 2012. All rights reserved.

Product data sheet                                        Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                    192132                                                                               19 of 35
NXP Semiconductors                                                                 SL2S5302; SL2S5402

                                                                                                                                                       ICODE SLIX-S

                              •    Mask length

                              •    Mask value (if mask length > 0)

                              •    First page number to be read

                              •    Number of pages to be read

                              •    CRC 16

Table 41.          Request format

SOF  Flags         INVENTORY       IC Mfg       Optional     Mask       Mask          First page                                         Number of  CRC16       EOF

                   PAGE READ       code         AFI          length     value         number                                             pages

-    8 bits        8 bits          8 bits       8 bits       8 bits     0 to 64 bits  8 bits                                             8 bits     16 bits     -

                           The Inventory_flag must be set to logic 1.

                           The meaning of flags 5 to 8 is in accordance with table 5 in ISO/IEC 15693-3.

                           The number of pages in the request is one less than the number of pages that the ICODE

                           SLIX-S IC returns in its response.

                           If the Option flag in the request is set to logic 0, the response contains:

                           Table 42.       Response format: Option flag logic 0

                           SOF                  Flags                Data                                                       CRC16               EOF

                           -                    8 bits               Page status & data                                         16 bits             -

                                                                     Repeated as needed

                           The ICODE SLIX-S IC reads the requested page(s) including page protection status and

                           sends back their value in the response. The mechanism and timing of the INVENTORY

                           PAGE READ command performs the same as the INVENTORY command which is

                           described in clause 8 of ISO/IEC 15693-3.

                           The requested page(s) is (are) transmitted in the following format and repeated as

                           necessary (depending on number of pages):

                           Table 43.       Page protection status byte

                           Page Protection Status byte                                                                          Page data

                           00h:    page is public (not protected with Read password) or the                                     16 byte page data content

                                   valid Read password has been transmitted before

                           0Fh:    page is protected with the Read password and the valid                                       no data

                                   Read password has not been transmitted before

                           If the Option flag in the request is set to logic 1, the response contains:

                           Table 44.       Response format: Option flag logic 1

                           SOF        Flags     Rest of UID which is not part of                                          Data                      CRC16    EOF

                                                the mask and slot number

                           -          8 bits    0 to 64 bit                                                               Page status & data        16 bits  -

                                                Multiple of 8 bits                                                        Repeated as needed

                           The ICODE SLIX-S IC reads the requested page(s) including page protection status and

                           sends back their value in the response. Additionally the bytes of the UID, which are not

                           parts of the mask and the slot number in case of 16 slots, are returned. Instead of padding

SL2S5302_SL2S5402                             All information provided in this document is subject to legal disclaimers.                         © NXP B.V. 2012. All rights reserved.

Product data sheet                                      Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                               192132                                                                                             20 of 35
NXP  Semiconductors                                                         SL2S5302; SL2S5402

                                                                                                                                                     ICODE SLIX-S

                             with zeros up to the next byte boundary, the corresponding bits of the UID are returned.

                             The mechanism and timing of the INVENTORY PAGE READ command perform the same

                             as the INVENTORY command which is described in clause 8 of ISO/IEC 15693-3.

                             The requested page(s) is (are) transmitted in the following format and repeated as

                             necessary (depending on number of pages):

                             Table 45.    Page protection status byte

                             Page Protection Status Byte                                                                               Page data

                             00h:    page is public (not protected with Read password) or the                                          16 byte page data content

                                     valid Read password has been transmitted before

                             0Fh:    page is protected with the Read password and the valid                                            no data

                                     Read password has not been transmitted before

                             Remark: The number of bits of the re-transmitted UID can be calculated as follows:

                             •  16 slots: 60 bits (bit 64 to bit 5) - mask length rounded up to the next byte boundary

                             •  1 slot: 64 bits - mask length rounded up to the next byte boundary

                             Remark: If the sum of first page number and number of pages exceeds the total available

                             number of user pages, the number of transmitted pages is less than the requested

                             number of pages, which means that the last returned page is the highest available user

                             page, followed by the 16-bit CRC and the EOF.

                             •  Example: mask length = 30 bits

                             •  Returned: bit 64 to bit 5 (30 bits) = 30 bits gives 4 bytes

                             Table 46.    Example: mask length = 30

                             Byte 0     Byte 1  Byte 2  Byte 3  Byte 4  Byte 5                                                 Byte 6  Byte 7   UID

                             mask value including padding with                                                              -                   transmitted by

                                          zeros                                                                                                 interrogator

                                                                        returned value                                                          transmitted by

                                                                                                                                                ICODE SLIX-S IC

                   8.4.3.12  FAST INVENTORY PAGE READ

                             Command code = B1h

                             When receiving the FAST INVENTORY PAGE READ command the ICODE SLIX-S IC

                             behaves the same as the INVENTORY PAGE READ command with the following

                             exceptions:

                             The data rate in the direction ICODE SLIX-S IC to the interrogator is twice that defined in

                             ISO/IEC 15693-3, depending on the Datarate_flag 53 kbit (high data rate) or 13 kbit (low

                             data rate).

                             The data rate from the interrogator to the ICODE SLIX-S IC and the time between the

                             rising edge of the EOF from the interrogator to the ICODE SLIX-S IC remain unchanged

                             (stay the same as defined in ISO/IEC 15693-3).

                             In the ICODE SLIX-S IC to the interrogator direction, only the single subcarrier mode is

                             supported.

SL2S5302_SL2S5402                               All information provided in this document is subject to legal disclaimers.                           © NXP B.V. 2012. All rights reserved.

Product data sheet                               Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                  192132                                                                                            21 of 35
NXP Semiconductors                                                             SL2S5302; SL2S5402

                                                                                                                                                       ICODE SLIX-S

                   8.4.3.13  SET EAS

                             Command code = A2h

                             The SET EAS command enables the EAS mode if the EAS mode is not locked.                                                    If the EAS

                             mode is password protected the EAS password has to be first transmitted with                                               the SET

                             PASSWORD command.

                             The timing of the command is write alike.

                             Option 0 (Option flag not set) is supported.

                             Option 1 (Option flag set) is supported.

                             Table 47.  Request format

                             SOF        Flags           SET EAS        IC Mfg code                                          UID               CRC16     EOF

                             -          8 bits          8 bits         8 bits                                               64 bits           16 bits   -

                                                                                                                            optional

                             Table 48.  Response format when Error_flag set

                             SOF                Flags            Error code                                                 CRC16                  EOF

                             -                  8 bits           8 bits                                                     16 bits                -

                             Table 49.  Response format when Error_flag NOT set

                             SOF                 Flags                         CRC16                                                          EOF

                             -                   8 bits                        16 bits                                                        -

                   8.4.3.14  RESET EAS

                             Command code = A3h

                             The RESET EAS command disables the EAS mode if the EAS mode is not locked. If the

                             EAS mode is password protected the EAS password has to be first transmitted with the

                             SET PASSWORD command.

                             The timing of the command is write alike.

                             Option 0 (Option flag not set) is supported.

                             Option 1 (Option flag set) is supported.

                             Table 50.  Request format

                             SOF        Flags   RESET EAS        IC Mfg code                                                UID               CRC16     EOF

                             -          8 bits  8 bits           8 bits                                                     64 bits optional  16 bits   -

                             Table 51.  Response format when Error_flag set

                             SOF                Flags            Error code                                                 CRC16                  EOF

                             -                  8 bits           8 bits                                                     16 bits                -

                             Table 52.  Response format when Error_flag NOT set

                             SOF                 Flags                         CRC16                                                          EOF

                             -                   8 bits                        16 bits                                                        -

SL2S5302_SL2S5402                               All information provided in this document is subject to legal disclaimers.                       © NXP B.V. 2012. All rights reserved.

Product data sheet                               Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                           192132                                                                                            22 of 35
NXP Semiconductors                                                                      SL2S5302; SL2S5402

                                                                                                                                                ICODE SLIX-S

                   8.4.3.15  LOCK EAS

                             Command code = A4h

                             The LOCK EAS command locks the current state of the EAS mode and the EAS ID. If the

                             EAS mode is password protected the EAS password has to be first transmitted with the

                             SET PASSWORD command.

                             The timing of the command is write alike.

                             Option 0 (Option flag not set) is supported.

                             Option 1 (Option flag set) is supported.

                             Table 53.      Request format

                             SOF                Flags           LOCK EAS        IC Mfg code                                 UID       CRC16              EOF

                             -                  8 bits          8 bits          8 bits                                      64 bits   16 bits            -

                                                                                                                            optional

                             Table 54.      Response format when Error_flag set

                             SOF                        Flags                   Error code                                  CRC16            EOF

                             -                          8 bits                  8 bits                                      16 bits          -

                             Table 55.      Response format when Error_flag NOT set

                             SOF                        Flags                           CRC16                                         EOF

                             -                          8 bits                          16 bits                                       -

                   8.4.3.16  EAS ALARM

                             Command code = A5h

                             The EAS ALARM command can be used in the following three configurations:

                                •  Option flag is set to 0:

                                   EAS ID mask length and EAS ID value shall not be transmitted.

                                   If the EAS mode is enabled, the EAS response is returned from the ICODE SLIX-S IC.

                                   This configuration is compliant with the EAS command of the ICODE SLI IC.

                                •  Option flag is set to 1:

                                   Within the command the EAS ID mask length has to be transmitted to identify how

                                   many bits of the following EAS ID value are valid (multiple of 8-bits). Only those

                                   ICODE SLIX-S ICs will respond with the EAS sequence which have stored the

                                   corresponding data in the EAS ID configuration (selective EAS) and if the EAS Mode

                                   is set.

                                   If the EAS ID mask length is set to 0, the ICODE SLIX-S IC will answer with its EAS

                                   ID.

                             Table 56.      Request format

                             SOF        Flags   EAS             IC Mfg  UID             EAS ID mask                         EAS ID value        CRC16       EOF

                                                ALARM           code                    length

                             -          8 bits  8 bits          8 bits  64 bits         8 bits optional                     0, 8 or 16 bits     16 bits     -

                                                                        optional                                            optional

SL2S5302_SL2S5402                               All information provided in this document is subject to legal disclaimers.                   © NXP B.V. 2012. All rights reserved.

Product data sheet                                      Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                          192132                                                                                 23 of 35
NXP Semiconductors                                                               SL2S5302; SL2S5402

                                                                                                                                                 ICODE SLIX-S

                             If an error is detected the ICODE SLIX-S IC remains silent.

                             Option flag is set to logic 0 or Option flag is set to logic 1 and the EAS ID mask length is

                             not equal to 0:

                             Table 57.  Response format

                             SOF                  Flags             EAS sequence                                          CRC16               EOF

                             -                    8 bits            256 bits                                              16 bits             -

                             EAS sequence (starting with the LSB, which is transmitted first; read from left to right):

                             11110100   11001101  01000110  00001110        10101011                                      11100101  00001001     11111110

                             00010111   10001101  00000001  00011100        01001011                                      10000001  10010010     01101110

                             01000001   01011011  01011001  01100001        11110110                                      11110101  11010001     00001101

                             10001111   00111001  10001011  01001000        10100101                                      01001110  11101100     11110111

                             Option flag is set to logic 1 and the EAS ID mask length is equal to 0:

                             Table 58.  Response format

                             SOF                  Flags             EAS ID value                                          CRC16               EOF

                             -                    8 bits            16 bits                                               16 bits             -

                             If the EAS mode is disabled (see RESET EAS command in Section 8.4.3.14 “RESET

                             EAS”), the ICODE SLIX-S IC remains silent.

                   8.4.3.17  PASSWORD PROTECT EAS/AFI

                             Command code = A6h

                             The PASSWORD PROTECT EAS/AFI command enables the password protection for

                             EAS and/or AFI if the EAS/AFI password is first transmitted with the SET PASSWORD

                             command.

                             Option flag set to logic 0: EAS will be password protected.

                             Option flag set to logic 1: AFI will be password protected.

                             Both password protections (AFI and EAS) can be enabled separately.

                             Remark: Independent of the Option flag, this write-alike command will be executed like a

                             write command with Option flag 0 (Option flag not set).

                             Once the EAS/AFI password protection is enabled, it is not possible to change back to

                             unprotected EAS and/or AFI.

                             The timing of the command is write alike (as write command with Option flag 0).

                             Table 59.  Request format

                             SOF  Flags       PASSWORD              IC Mfg code                                           UID                 CRC16        EOF

                                              PROTECT EAS/AFI

                             -    8 bits      8 bits                8 bits                                                64 bits optional    16 bits      -

                             Table 60.  Response format when Error_flag set

                             SOF                  Flags             Error code                                            CRC16               EOF

                             -                    8 bits            8 bits                                                16 bits             -

SL2S5302_SL2S5402                             All information provided in this document is subject to legal disclaimers.                      © NXP B.V. 2012. All rights reserved.

Product data sheet                                    Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                              192132                                                                                         24 of 35
NXP  Semiconductors                                                        SL2S5302; SL2S5402

                                                                                                                                            ICODE SLIX-S

                             Table 61.  Response format when Error_flag NOT set

                             SOF                  Flags                    CRC16                                                EOF

                             -                    8 bits                   16 bits                                              -

                   8.4.3.18  WRITE EAS ID

                             Command code = A7h

                             The command WRITE EAS ID enables a new EAS Identifier to be stored in the

                             corresponding configuration memory. If EAS is password protectd (for Set and Reset

                             EAS) the EAS password has to be first transmitted with the SET PASSWORD command.

                             The timing of the command is write alike.

                             Table 62.  Request format

                             SOF        Flags   WRITE      IC Mfg code           UID                                   EAS ID      CRC16    EOF

                                                EAS ID                                                                 value

                             -          8 bits  8 bits     8 bits                64 bits                               16 bits     16 bits  -

                                                                                 optional

                             Table 63.  Response format when Error_flag set

                             SOF                Flags              Error code                                          CRC16         EOF

                             -                  8 bits             8 bits                                              16 bits       -

                             Table 64.  Response format when Error_flag NOT set

                             SOF                  Flags                    CRC16                                                EOF

                             -                    8 bits                   16 bits                                              -

                    8.5      Error handling

                   8.5.1     Transmission errors

                             According to ISO/IEC 15693 the label IC will not respond if a transmission error (CRC, bit

                             coding, bit count, wrong framing) is detected and will silently wait for the next correct

                             received command.

                   8.5.2     Not supported commands or options

                             If the received command or option is not supported, the behavior of the label IC depends

                             on the addressing mechanism.

                   8.5.2.1   Non Addressed Mode

                             The label IC remains silent.

                   8.5.2.2   Addressed or Selected Mode

                             The addressed or selected label IC responds with the error code “0Fh” (error with no

                             information given or error code is not supported).

                             If the Inventory flag or the Protocol Extension flag is set, the label IC will not respond if the

                             command or option is not supported.

SL2S5302_SL2S5402                          All information provided in this document is subject to legal disclaimers.              © NXP B.V. 2012. All rights reserved.

Product data sheet                              Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                             192132                                                                              25 of 35
NXP  Semiconductors                                                           SL2S5302; SL2S5402

                                                                                                                      ICODE SLIX-S

                   8.5.3    Parameter out of range

                   8.5.3.1  Read commands

                            If the sum of the first block number and the number of blocks exceeds the total available

                            number of user blocks, the number of transmitted blocks is less than the requested

                            number of blocks, which means that the last returned block is the highest available user

                            block, followed by the 16-bit CRC and the EOF.

                   8.5.3.2  Write and lock commands

                            If the address of a block to be written does not exist or a block to be written is locked, the

                            behaviour of the label IC depends on the addressing mechanism.

                            Non Addressed Mode

                            •  The label IC remains silent and aborts the command without writing anything.

                            Addressed or Selected Mode

                            •  The addressed or selected label IC responds with the error code “0Fh” (error with no

                               information given or error code is not supported).

                    8.6     Data integrity

                            Following mechanisms are implemented in the contactless communication link between

                            interrogator and label to ensure very reliable data transmission:

                            •  16-bit CRC per block

                            •  Bit count checking

                            •  Bit coding to distinguish between logic 1, logic 0, and no information

                            •  Channel monitoring (protocol sequence and bit stream analysis)

                    8.7     RF interface

                            The definition of the RF interface is according to the standard ISO/IEC 15693-2 and

                            ISO/IEC 15693-3.

SL2S5302_SL2S5402                         All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                                 Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                          192132                                                        26 of 35
NXP Semiconductors                                                                    SL2S5302; SL2S5402

                                                                                                                                                                ICODE SLIX-S

9.       Limiting values

Table 65.          Limiting values (Wafer)[1][2]

In accordance with the Absolute Maximum Rating      System            (IEC  60134).

Symbol             Parameter                                                Conditions                                                             Min     Max       Unit

Tstg               storage temperature                                                                                                             55     +125      C

Ptot               total power dissipation                                                                                                         -       125       mW

Tj                 junction temperature                                                                                                            40     +85       C

Ii(max)            maximum input current                                    LA to LB; peak                                                 [3]     -       60       mA

II                 input current                                            LA to LB; RMS                                                          -       30        mA

VESD               electrostatic discharge voltage                          Human body model                                               [4]     -       2        kV

[1]   Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only

      and functional operation of the device at these or any conditions other than those described in the operating conditions and electrical

      characteristics sections of this specification is not implied.

[2]   This product includes circuitry specifically designed for the protection of its internal devices from the damaging effects of excessive static

      charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying greater than the rated maxima.

[3]   The voltage between LA and LB is limited by the on-chip voltage limitation circuitry (corresponding to parameter II).

[4]   For ESD measurement, the IC was mounted in a CDIP8 package.

10. Characteristics

                   10.1       Wafer memory characteristics

Table 66.          Wafer EEPROM characteristics

Symbol             Parameter                        Conditions                        Min                                             Typ               Max          Unit

tret               retention time                   Tamb  55 C                     50                                              -                 -            year

Nendu(W)           write endurance                                                    100000                                          -                 -            cycle

                   10.2       Interface characteristics

Table 67.          Interface characteristics

Typical ratings are not guaranteed. The values      listed       are  at  room temperature.

Symbol             Parameter                                              Conditions                                               Min          Typ          Max     Unit

fi                 input frequency                                                                                            [1]  13.553       13.56        13.567  MHz

Vi(RMS)min         minimum RMS input voltage                              operating                                                1.5          -            1.7     V

                                                                          read/write

Pi(min)            minimum input power                                    operating                                           [2]  -            40           -       W

Ci                 input capacitance                                      between LA                                          [3]

                                                                          and LB

                                                                            SL5302FUD                                              22.3         23.5         24.7    pF

                                                                            SL5402FUD                                              92           97           102     pF

[1]   Bandwidth limitation ( 7 kHz) according to ISM band regulations.

[2]   Including losses in the resonant capacitor and rectifier.

[3]   Measured with an HP4285A LCR meter at 13.56 MHz and 2 V RMS.

SL2S5302_SL2S5402                                 All information provided in this document is subject to legal disclaimers.                               © NXP B.V. 2012. All rights reserved.

Product data sheet                                  Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                            192132                                                                                     27 of 35
NXP Semiconductors                                                      SL2S5302; SL2S5402

                                                                                                                            ICODE SLIX-S

11. Bare die outline

                            (1)

                                                             LA                                         LB

                                                                        (5)

                                                             Y

                                                                                                            (6)  (4)

                                                                             X

                                 (7)

                                                             GND                TEST

                                                                  (8)

                                 (2)

                                                                        (3)

                                                                        not to scale!                            001aam108

                            (1) X-scribe line width: 15 m

                            (2) Y-scribe line width: 15 m

                            (3) Chip step, X-length: 535 m

                            (4) Chip step, Y-length: 499 m

                            (5) Bump to bump distance X (LA - LB): 400 m

                            (6) Bump to bump distance Y (LB - TEST): 360 m

                            (7) Distance bump to nitride edge X: 75 m

                            (8) Distance bump to nitride edge Y: 45 m

                            Bump size X  Y: 60 m  60 m

                    Fig 4.  Wafer SL2S5302FUD bare die layout

SL2S5302_SL2S5402           All information provided in this document is subject to legal disclaimers.           © NXP      B.V.  2012.  All  rights reserved.

Product data sheet          Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                   192132                                                                                                       28 of 35
NXP Semiconductors                                                      SL2S5302; SL2S5402

                                                                                                                            ICODE SLIX-S

                            (1)

                                                             LA                                         LB

                                                                        (5)

                                                                                                            (6)  (4)

                                                             Y

                                                                             X

                                 (7)

                                                             GND                TEST

                                                                  (8)

                                 (2)

                                                                        (3)

                                                                        not to scale!                            001aam545

                            (1) X-scribe line width: 15 m

                            (2) Y-scribe line width: 15 m

                            (3) Chip step, X-length: 535 m

                            (4) Chip step, Y-length: 622 m

                            (5) Bump to bump distance X (LA - LB): 400 m

                            (6) Bump to bump distance Y (LB - TEST): 517 m

                            (7) Distance bump to nitride edge X: 75 m

                            (8) Distance bump to nitride edge Y: 45 m

                            Bump size X  Y: 60 m  60 m

                    Fig 5.  Wafer SL2S5402FUD bare die layout

SL2S5302_SL2S5402           All information provided in this document is subject to legal disclaimers.           © NXP      B.V.  2012.  All  rights reserved.

Product data sheet          Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                   192132                                                                                                       29 of 35
NXP Semiconductors                                                              SL2S5302; SL2S5402

                                                                                                                ICODE SLIX-S

12.  Abbreviations

                    Table 68.       Abbreviations

                    Acronym                    Description

                    AFI                        Application Family Identifier

                    CRC                        Cyclic Redundancy Check

                    DSFID                      Data Storage Format Identifier

                    EAS                        Electronic Article Surveillance

                    EEPROM                     Electrically Erasable Programmable Read Only Memory

                    EOF                        End Of Frame

                    IC                         Integrated Circuit

                    LCR                        Inductance, Capacitance, Resistance

                    LSB                        Least Significant Byte/Bit

                    MSB                        Most Significant Byte/Bit

                    RF                         Radio Frequency

                    SOF                        Start Of Frame

                    UID                        Unique IDentifier

13.  References

                    [1]             ISO Standard — ISO/IEC 15693 - Identification cards - Contactless integrated

                                    circuit cards - Vicinity cards.

                    [2]             ISO Standard — ISO/IEC 15693-2 -Identification cards - Contactless integrated

                                    circuit cards - Vicinity cards - Part 2: Air interface and initialization.

                    [3]             ISO Standard — ISO/IEC 15693-3 -Identification cards - Contactless integrated

                                    circuit cards - Vicinity cards - Part 3: Anticollision and transmission protocol.

                    [4]             ISO Standard — ISO/IEC 18000-3 - Information technology - Radio frequency

                                    identification for item management - Part 3: Parameters for air interface

                                    communications at 13.56 MHz.

                    [5]             ISO Standard — ISO/IEC 7816-6 - Identification cards - Integrated circuit cards -

                                    Part 6: Interindustry data elements for interchange.

                    [6]             General specification for 8” wafer on UV-tape with electronic fail die

                                    marking —  Delivery type description – BL-ID document number: 1093**1.

1.  ** ... document version number

SL2S5302_SL2S5402                   All information provided in this document is subject to legal disclaimers.  © NXP B.V. 2012. All rights reserved.

Product data sheet                             Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                 192132                                                  30 of 35
NXP Semiconductors                                                            SL2S5302; SL2S5402

                                                                                                                                                  ICODE SLIX-S

14. Revision history

Table 69.          Revision history

Document ID                          Release date  Data sheet status                                                       Change notice  Supersedes

SL2S5302_SL2S5402 v.3.2              20120827      Product data sheet                                                      -              SL2S5302_SL2S5402

                                                                                                                                          v.3.1

Modifications:                       •  Security status changed into “COMPANY PUBLIC”

SL2S5302_SL2S5402 v.3.1              20100930      Product data sheet                                                      -              SL2S5302 v.3.0

Modifications:                       •  Added type number SL2S5402

                                     •  Document layout updated

                                     •  Table 67: symbols and parameter descriptions updated

SL2S5302 v.3.0                       20100527      Product data sheet                                                      -              192120

192120                               20100517      Preliminary data sheet                                                  -              -

SL2S5302_SL2S5402                              All information provided in this document is subject to legal disclaimers.                        © NXP B.V. 2012. All rights reserved.

Product data sheet                                 Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                     192132                                                                                                 31 of 35
NXP Semiconductors                                                                                      SL2S5302; SL2S5402

                                                                                                                                                         ICODE SLIX-S

15. Legal information

15.1  Data sheet status

Document status[1][2]                Product status[3]                    Definition

Objective [short] data sheet         Development                          This document contains data from the objective specification for product development.

Preliminary [short] data sheet       Qualification                        This document contains data from the preliminary specification.

Product [short] data sheet           Production                           This document contains the product specification.

[1]  Please consult the most recently issued document before initiating or completing a design.

[2]  The term ‘short data sheet’ is explained in section “Definitions”.

[3]  The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status

     information is available on the Internet at URL http://www.nxp.com.

15.2  Definitions                                                                                Suitability for use — NXP Semiconductors products are not designed,

                                                                                                 authorized or warranted to be suitable for use in life support, life-critical or

Draft — The document is a draft version only. The content is still under                         safety-critical systems or equipment, nor in applications where failure or

internal review and subject to formal approval, which may result in                              malfunction of an NXP Semiconductors product can reasonably be expected

modifications or additions. NXP Semiconductors does not give any                                 to result in personal injury, death or severe property or environmental

representations or warranties as to the accuracy or completeness of                              damage. NXP Semiconductors and its suppliers accept no liability for

information included herein and shall have no liability for the consequences of                  inclusion and/or use of NXP Semiconductors products in such equipment or

use of such information.                                                                         applications and therefore such inclusion and/or use is at the customer’s own

                                                                                                 risk.

Short data sheet — A short data sheet is an extract from a full data sheet                       Applications — Applications that are described herein for any of these

with the same product type number(s) and title. A short data sheet is intended                   products are for illustrative purposes only. NXP Semiconductors makes no

for quick reference only and should not be relied upon to contain detailed and                   representation or warranty that such applications will be suitable for the

full information. For detailed and full information see the relevant full data                   specified use without further testing or modification.

sheet, which is available on request via the local NXP Semiconductors sales

office. In case of any inconsistency or conflict with the short data sheet, the                  Customers are responsible for the design and operation of their applications

full data sheet shall prevail.                                                                   and products using NXP Semiconductors products, and NXP Semiconductors

Product specification — The information and data provided in a Product                           accepts no liability for any assistance with applications or customer product

data sheet shall define the specification of the product as agreed between                       design. It is customer’s sole responsibility to determine whether the NXP

NXP Semiconductors and its customer, unless NXP Semiconductors and                               Semiconductors product is suitable and fit for the customer’s applications and

customer have explicitly agreed otherwise in writing. In no event however,                       products planned, as well as for the planned application and use of

shall an agreement be valid in which the NXP Semiconductors product is                           customer’s third party customer(s). Customers should provide appropriate

deemed to offer functions and qualities beyond those described in the                            design and operating safeguards to minimize the risks associated with their

Product data sheet.                                                                              applications and products.

                                                                                                 NXP Semiconductors does not accept any liability related to any default,

                                                                                                 damage, costs or problem which is based on any weakness or default in the

15.3  Disclaimers                                                                                customer’s applications or products, or the application or use by customer’s

                                                                                                 third party customer(s). Customer is responsible for doing all necessary

Limited warranty and liability — Information in this document is believed to                     testing for the customer’s applications and products using NXP

be accurate and reliable. However, NXP Semiconductors does not give any                          Semiconductors products in order to avoid a default of the applications and

representations or warranties, expressed or implied, as to the accuracy or                       the products or of the application or use by customer’s third party

completeness of such information and shall have no liability for the                             customer(s). NXP does not accept any liability in this respect.

consequences of use of such information. NXP Semiconductors takes no                             Limiting values — Stress above one or more limiting values (as defined in

responsibility for the content in this document if provided by an information                    the Absolute Maximum Ratings System of IEC 60134) will cause permanent

source outside of NXP Semiconductors.                                                            damage to the device. Limiting values are stress ratings only and (proper)

In no event shall NXP Semiconductors be liable for any indirect, incidental,                     operation of the device at these or any other conditions above those given in

punitive, special or consequential damages (including - without limitation - lost                the Recommended operating conditions section (if present) or the

profits, lost savings, business interruption, costs related to the removal or                    Characteristics sections of this document is not warranted. Constant or

replacement of any products or rework charges) whether or not such                               repeated exposure to limiting values will permanently and irreversibly affect

damages are based on tort (including negligence), warranty, breach of                            the quality and reliability of the device.

contract or any other legal theory.                                                              Terms and conditions of commercial sale — NXP Semiconductors

Notwithstanding any damages that customer might incur for any reason                             products are sold subject to the general terms and conditions of commercial

whatsoever, NXP Semiconductors’ aggregate and cumulative liability towards                       sale, as published at http://www.nxp.com/profile/terms, unless otherwise

customer for the products described herein shall be limited in accordance                        agreed in a valid written individual agreement. In case an individual

with the Terms and conditions of commercial sale of NXP Semiconductors.                          agreement is concluded only the terms and conditions of the respective

                                                                                                 agreement shall apply. NXP Semiconductors hereby expressly objects to

Right to make changes — NXP Semiconductors reserves the right to make                            applying the customer’s general terms and conditions with regard to the

changes to information published in this document, including without                             purchase of NXP Semiconductors products by customer.

limitation specifications and product descriptions, at any time and without                      No offer to sell or license — Nothing in this document may be interpreted or

notice. This document supersedes and replaces all information supplied prior                     construed as an offer to sell products that is open for acceptance or the grant,

to the publication hereof.                                                                       conveyance or implication of any license under any copyrights, patents or

                                                                                                 other industrial or intellectual property rights.

SL2S5302_SL2S5402                                       All information provided in this document is subject to legal disclaimers.                       © NXP B.V. 2012. All rights reserved.

Product data sheet                                                        Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                                        192132                                                                                 32 of 35
NXP Semiconductors                                                                          SL2S5302; SL2S5402

                                                                                                                                                      ICODE SLIX-S

Export control — This document as well as the item(s) described herein              whenever customer uses the product for automotive applications beyond

may be subject to export control regulations. Export might require a prior          NXP Semiconductors’ specifications such use shall be solely at customer’s

authorization from competent authorities.                                           own risk, and (c) customer fully indemnifies NXP Semiconductors for any

Quick reference data — The Quick reference data is an extract of the                liability, damages or failed product claims resulting from customer design and

product data given in the Limiting values and Characteristics sections of this      use of the product for automotive applications beyond NXP Semiconductors’

document, and as such is not complete, exhaustive or legally binding.               standard warranty and NXP Semiconductors’ product specifications.

Non-automotive qualified products — Unless this data sheet expressly                Translations — A non-English (translated) version of a document is for

states that this specific NXP Semiconductors product is automotive qualified,       reference only. The English version shall prevail in case of any discrepancy

the product is not suitable for automotive use. It is neither qualified nor tested  between the translated and English versions.

in accordance with automotive testing or application requirements. NXP

Semiconductors accepts no liability for inclusion and/or use of                     15.4    Trademarks

non-automotive qualified products in automotive equipment or applications.

In the event that customer uses the product for design-in and use in                Notice: All referenced brands, product names, service names and trademarks

automotive applications to automotive specifications and standards, customer        are the property of their respective owners.

(a) shall use the product without NXP Semiconductors’ warranty of the               ICODE and I-CODE                   —  are trademarks of NXP B.V.

product for such automotive applications, use and specifications, and (b)

16. Contact information

For more information, please visit: http://www.nxp.com

For sales office addresses, please send an email to: salesaddresses@nxp.com

SL2S5302_SL2S5402                          All information provided in this document is subject to legal disclaimers.             © NXP B.V. 2012. All rights reserved.

Product data sheet                                               Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                                      192132                                                             33 of 35
NXP Semiconductors                                                                                SL2S5302; SL2S5402

                                                                                                                                 ICODE SLIX-S

17. Tables

Table 1.   Ordering information  . . . . . . . . . . . . . . . . . . . . .3          Table   36.  Response format when Error_flag set   ...                   .  .  .  18

Table 2.   Bonding pad description  . . . . . . . . . . . . . . . . . .5             Table   37.  Response format when Error_flag NOT set                        .  .  18

Table 3.   Wafer specification . . . . . . . . . . . . . . . . . . . . . . .6        Table   38.  Request format  .....................                       .  .  .  19

Table 4.   Memory organization . . . . . . . . . . . . . . . . . . . . .9            Table   39.  Response format when Error_flag set   ...                   .  .  .  19

Table 5.   Unique identifier . . . . . . . . . . . . . . . . . . . . . . . . .9      Table   40.  Response format when Error_flag NOT set                        .  .  19

Table 6.   Request format     . . . . . . . . . . . . . . . . . . . . . . . .12      Table   41.  Request format  .....................                       .  .  .  20

Table 7.   Response format when Error_flag set . . . . . . .12                       Table   42.  Response format: Option flag logic 0  ....                  .  .  .  20

Table 8.   Response format when Error_flag NOT set . . .12                           Table   43.  Page protection status byte    ...........                  .  .  .  20

Table 9.   Request format     . . . . . . . . . . . . . . . . . . . . . . . .13      Table   44.  Response format: Option flag logic 1  ....                  .  .  .  20

Table 10.  Password Identifier   . . . . . . . . . . . . . . . . . . . . .13         Table   45.  Page protection status byte    ...........                  .  .  .  21

Table 11.  Response format when Error_flag set . . . . . . .13                       Table   46.  Example: mask length = 30 . . . . . . . . . . . .           .  .  .  21

Table 12.  Response format when Error_flag NOT set . . .13                           Table   47.  Request format  .....................                       .  .  .  22

Table 13.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .14      Table   48.  Response format when Error_flag set   ...                   .  .  .  22

Table 14.  Password Identifier   . . . . . . . . . . . . . . . . . . . . .14         Table   49.  Response format when Error_flag NOT set                        .  .  22

Table 15.  Response format when Error_flag set . . . . . . .14                       Table   50.  Request format  .....................                       .  .  .  22

Table 16.  Response format when Error_flag NOT set . . .14                           Table   51.  Response format when Error_flag set   ...                   .  .  .  22

Table 17.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .14      Table   52.  Response format when Error_flag NOT set                        .  .  22

Table 18.  Password identifier   . . . . . . . . . . . . . . . . . . . . .15         Table   53.  Request format  .....................                       .  .  .  23

Table 19.  Response format when Error_flag set . . . . . . .15                       Table   54.  Response format when Error_flag set   ...                   .  .  .  23

Table 20.  Response format when Error_flag NOT set . . .15                           Table   55.  Response format when Error_flag NOT set                        .  .  23

Table 21.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .15      Table   56.  Request format  .....................                       .  .  .  23

Table 22.  Response format when Error_flag set . . . . . . .15                       Table   57.  Response format . . . . . . . . . . . . . . . . . . . .     .  .  .  24

Table 23.  Response format when Error_flag NOT set . . .15                           Table   58.  Response format . . . . . . . . . . . . . . . . . . . .     .  .  .  24

Table 24.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .16      Table   59.  Request format  .....................                       .  .  .  24

Table 25.  Protection status    . . . . . . . . . . . . . . . . . . . . . . .16      Table   60.  Response format when Error_flag set   ...                   .  .  .  24

Table 26.  Response format when Error_flag set . . . . . . .16                       Table   61.  Response format when Error_flag NOT set                        .  .  25

Table 27.  Response format when Error_flag NOT set . . .16                           Table   62.  Request format  .....................                       .  .  .  25

Table 28.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .17      Table   63.  Response format when Error_flag set   ...                   .  .  .  25

Table 29.  Response format when Error_flag set . . . . . . .17                       Table   64.  Response format when Error_flag NOT set                        .  .  25

Table 30.  Response format when Error_flag NOT set . . .17                           Table   65.  Limiting values (Wafer)[1][2]  ............                 .  .  .  27

Table 31.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .17      Table   66.  Wafer EEPROM characteristics   ........                     .  .  .  27

Table 32.  Response format when Error_flag set . . . . . . .17                       Table   67.  Interface characteristics      ..............               .  .  .  27

Table 33.  Response format when Error_flag NOT set . . .17                           Table   68.  Abbreviations   ......................                      .  .  .  30

Table 34.  Block protection status . . . . . . . . . . . . . . . . . . .18           Table   69.  Revision history . . . . . . . . . . . . . . . . . . . . .  .  .  .  31

Table 35.  Request format     . . . . . . . . . . . . . . . . . . . . . . . .18

18. Figures

Fig 1.    Block diagram of ICODE SLIX-S . . . . . . . . . . . . . .3

Fig 2.    Wafer SL2S5302FUD layout and pin configuration

           for the bare die. . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Fig 3.    Wafer SL2S5402FUD layout and pin configuration

           for the bare die. . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Fig 4.     Wafer SL2S5302FUD bare die layout . . . . . . . . .28

Fig 5.     Wafer SL2S5402FUD bare die layout . . . . . . . . .29

SL2S5302_SL2S5402                   All information provided in this document is subject to legal disclaimers.                   © NXP B.V. 2012. All rights reserved.

Product data sheet                  Rev. 3.2 — 27 August 2012

COMPANY PUBLIC                                                                       192132                                                                   34 of 35
NXP Semiconductors                                                                                     SL2S5302; SL2S5402

                                                                                                                                                                 ICODE SLIX-S

19. Contents

1         General description . . . . . . . . . . . . . . . . . . . . . .              1   8.4.3.8     GET MULTIPLE BLOCK PROTECTION

1.1       Contactless energy and data transfer. . . . . . . .                          1               STATUS . . . . . . . . . . . . . . . . . . . . . . . . .         .  .  .  .     17

1.2       Anticollision. . . . . . . . . . . . . . . . . . . . . . . . . . . .         1   8.4.3.9     DESTROY SLIX-S . . . . . . . . . . . . . . . . .                 .  .  .  .     18

1.3       Security and privacy aspects . . . . . . . . . . . . . .                     1   8.4.3.10    ENABLE PRIVACY . . . . . . . . . . . . . . . .                   .  .  .  .     19

2         Features and benefits . . . . . . . . . . . . . . . . . . . .                2   8.4.3.11    INVENTORY PAGE READ                         ..........           .  .  .  .     19

2.1       ICODE SLIX-S RF interface (ISO/IEC 15693) .                                  2   8.4.3.12    FAST INVENTORY PAGE READ                                  .....  .  .  .  .     21

2.2       EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .             2   8.4.3.13    SET EAS . . . . . . . . . . . . . . . . . . . . . . . .          .  .  .  .     22

2.3       Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .        2   8.4.3.14    RESET EAS. . . . . . . . . . . . . . . . . . . . . .             .  .  .  .     22

3         Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .         3   8.4.3.15    LOCK EAS . . . . . . . . . . . . . . . . . . . . . . .           .  .  .  .     23

                                                                                           8.4.3.16    EAS ALARM . . . . . . . . . . . . . . . . . . . . .              .  .  .  .     23

4         Ordering information . . . . . . . . . . . . . . . . . . . . .               3   8.4.3.17    PASSWORD PROTECT EAS/AFI . . . . .                               .  .  .  .     24

5         Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . .            3   8.4.3.18    WRITE EAS ID. . . . . . . . . . . . . . . . . . . .              .  .  .  .     25

6         Pinning information . . . . . . . . . . . . . . . . . . . . . .              4   8.5         Error handling  ....................                             .  .  .  .     25

6.1       Pin description . . . . . . . . . . . . . . . . . . . . . . . . .            5   8.5.1       Transmission errors . . . . . . . . . . . . . . . .              .  .  .  .     25

7         Mechanical specification  .................                                  6   8.5.2       Not supported commands or options . . .                          .  .  .  .     25

7.1       Wafer specification . . . . . . . . . . . . . . . . . . . . . .              6   8.5.2.1     Non Addressed Mode . . . . . . . . . . . . . .                   .  .  .  .     25

7.1.1     Fail die identification . . . . . . . . . . . . . . . . . . . . .            7   8.5.2.2     Addressed or Selected Mode. . . . . . . . .                      .  .  .  .     25

7.1.2     Map file distribution. . . . . . . . . . . . . . . . . . . . . .             7   8.5.3       Parameter out of range . . . . . . . . . . . . .                 .  .  .  .     26

8         Functional description    ...................                                8   8.5.3.1     Read commands . . . . . . . . . . . . . . . . . .                .  .  .  .     26

                                                                                           8.5.3.2     Write and lock commands . . . . . . . . . . .                    .  .  .  .     26

8.1       Block description  ...................                      .  .       .  .  8               Non Addressed Mode . . . . . . . . . . . . . .                   .  .  .  .  .  26

8.2       Memory organization . . . . . . . . . . . . . . . .         .  .       .  .  8               Addressed or Selected Mode. . . . . . . . .                      .  .  .  .  .  26

8.2.1     Unique identifier . . . . . . . . . . . . . . . . . . . .   .  .       .  .  9   8.6         Data integrity . . . . . . . . . . . . . . . . . . . . .         .  .  .  .     26

8.2.2     Configuration of delivered ICs . . . . . . . . .            .  .       .  .  9   8.7         RF interface . . . . . . . . . . . . . . . . . . . . . .         .  .  .  .     26

8.3       Communication principle . . . . . . . . . . . . .           .  .       .     10  9         Limiting values . . . . . . . . . . . . . . . . . . . .            .  .  .  .     27

8.4       Supported commands        ...............                   .  .       .     10  10        Characteristics . . . . . . . . . . . . . . . . . . . .            .  .  .  .     27

8.4.1     Mandatory commands . . . . . . . . . . . . . . .            .  .       .     10

8.4.1.1   INVENTORY. . . . . . . . . . . . . . . . . . . . . . .      .  .       .     10  10.1        Wafer memory characteristics . . . . . . . .                     .  .  .  .     27

8.4.1.2   STAY QUIET. . . . . . . . . . . . . . . . . . . . . . .     .  .       .     10  10.2        Interface characteristics . . . . . . . . . . . . .              .  .  .  .     27

8.4.2     Optional commands . . . . . . . . . . . . . . . . .         .  .       .     10  11        Bare die outline . . . . . . . . . . . . . . . . . . . .           .  .  .  .     28

8.4.2.1   READ SINGLE BLOCK . . . . . . . . . . . . . .               .  .       .     10  12        Abbreviations . . . . . . . . . . . . . . . . . . . . .            .  .  .  .     30

8.4.2.2   WRITE SINGLE BLOCK. . . . . . . . . . . . . .               .  .       .     10  13        References. . . . . . . . . . . . . . . . . . . . . . . .          .  .  .  .     30

8.4.2.3   LOCK BLOCK. . . . . . . . . . . . . . . . . . . . . .       .  .       .     11  14        Revision history . . . . . . . . . . . . . . . . . . .             .  .  .  .     31

8.4.2.4   SELECT . . . . . . . . . . . . . . . . . . . . . . . . . .  .  .       .     11  15        Legal information . . . . . . . . . . . . . . . . . .              .  .  .  .     32

8.4.2.5   RESET TO READY . . . . . . . . . . . . . . . . .            .  .       .     11

8.4.2.6   WRITE AFI . . . . . . . . . . . . . . . . . . . . . . . .   .  .       .     11  15.1        Data sheet status . . . . . . . . . . . . . . . . . .            .  .  .  .     32

8.4.2.7   LOCK AFI . . . . . . . . . . . . . . . . . . . . . . . . .  .  .       .     11  15.2        Definitions . . . . . . . . . . . . . . . . . . . . . . .        .  .  .  .     32

8.4.2.8   WRITE DSFID . . . . . . . . . . . . . . . . . . . . .       .  .       .     11  15.3        Disclaimers  ......................                              .  .  .  .     32

8.4.2.9   LOCK DSFID . . . . . . . . . . . . . . . . . . . . . .      .  .       .     11  15.4        Trademarks . . . . . . . . . . . . . . . . . . . . . .           .  .  .  .     33

8.4.2.10  GET SYSTEM INFORMATION. . . . . . . . .                     .  .       .     12  16        Contact information . . . . . . . . . . . . . . . .                .  .  .  .     33

8.4.3     Custom commands. . . . . . . . . . . . . . . . . .          .  .       .     12  17        Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . .     .  .  .  .     34

8.4.3.1   GET RANDOM NUMBER. . . . . . . . . . . . .                  .  .       .     12  18        Figures . . . . . . . . . . . . . . . . . . . . . . . . . . .      .  .  .  .     34

8.4.3.2   SET PASSWORD . . . . . . . . . . . . . . . . . . .          .  .       .     12  19        Contents. . . . . . . . . . . . . . . . . . . . . . . . . .        .  .  .  .     35

8.4.3.3   WRITE PASSWORD          ................                    .  .       .     13

8.4.3.4   LOCK PASSWORD . . . . . . . . . . . . . . . . .             .  .       .     14

8.4.3.5   64 BIT PASSWORD PROTECTION. . . . .                         .  .       .     15

8.4.3.6   PROTECT PAGE . . . . . . . . . . . . . . . . . . .          .  .       .     16

8.4.3.7   LOCK PAGE PROTECTION CONDITION                              .  .       .     16

                                                                                           Please be aware that important notices concerning this document and the product(s)

                                                                                           described herein, have been included in section ‘Legal information’.

                                                                                           © NXP B.V.  2012.                                                     All rights reserved.

                                                                                           For more information, please visit: http://www.nxp.com

                                                                                           For sales office addresses, please send an email to: salesaddresses@nxp.com

                                                                                                                                                   Date of release: 27 August 2012

                                                                                                                                                                                 192132
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

NXP:

SL2S5302FUD,003  SL2S5402FUD,003
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved