器件描述

RF Switch ICs .7-2.7GHz SP16T 24Pin -30C +90C

参数
产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Skyworks
产品种类:
Product Category:
RF Switch ICs
RoHS:YES
封装:
Packaging:
Cut Tape
封装:
Packaging:
MouseReel
封装:
Packaging:
Reel
商标:
Brand:
Skyworks Solutions, Inc.
Moisture Sensitive:Yes
产品类型:
Product Type:
RF Switch ICs
工厂包装数量:
Factory Pack Quantity:
3000
子类别:
Subcategory:
Wireless & RF Integrated Circuits

SKY13492-21器件文档内容

DATA SHEET

SKY13492-21: 0.7 to 2.7 GHz SP16T                                             MIPI®         Antenna                Switch

Module

Applications

 2G/3G/4G multimode cellular handsets (LTE, UMTS, CDMA2000,

EDGE, GSM, TDD-LTE, TD-SCDMA)                                                 TRX1

 Embedded data cards                                                         TRX2

                                                                              TRX3

Features                                                                      TRX4

 Dedicated Band 7 TRX ports: 0.90 dB insertion loss @ 2.7 GHz                TRX5

 High isolation and linearity                                                TRX6

                                                                              TRX7

 Broadband frequency range: 0.7 to 2.7 GHz                                   TRX8

 Fourteen linear TRX ports                                                   TRX9                                                                                ANT

 Integrated low- and high-band GSM harmonic filters                          TRX10

 External MIPI select pin to enable multiple trigger controls                TRX11

 Small MCM (24-pin, 2.5 x 3.3 x 0.8 mm) package                              TRX12

(MSL3, 260 C per JEDEC J-STD-020)                                            TRX13

                                                                              TRX14

                                                                              TXHB

             Skyworks GreenTM products are compliant with                     TXLB

             all applicable legislation and are halogen-free.                                                                                         202826-001

             For additional information, refer to Skyworks                                       MIPI Decoder

             Definition of GreenTM, document number

             SQ04–0074.                                                                     VDD  VIO  SDATA  SCLK  MIPI_SELECT

                                                                              Figure 1. SKY13492-21 Block Diagram

Description

The SKY13492-21 is a single-pole, sixteen-throw (SP16T)             mode triggers. When this pin is grounded, the switch responds to

antenna switch with an integrated Mobile Industry Processor         any of the power mode triggers. When this pin is left open, the

Interface (MIPI) controller. Using an advanced switching            switch responds to individual power mode triggers. No external

technology, the SKY13492-21 maintains low insertion and high        DC blocking capacitors are required on the RF paths as long as no

isolation, which makes it an ideal choice for UMTS, CDMA2000,       DC voltage is applied.

EDGE, GSM, and LTE applications.                                    The SKY13492-21 is manufactured in a compact,

The design features two dedicated GSM transmit ports and three      2.5 x 3.3 x 0.8 mm, 24-pin surface mount Multi-Chip Module

dedicated ultra low-loss TRX ports. The switch also has an          (MCM) package.

excellent triple beat ratio and second/third order intermodulation  A functional block diagram is shown in Figure 1. The pin

distortion (IMD2/IMD3) performance.                                 configuration and package are shown in Figure 2. Signal pin

Switching is controlled by the MIPI decoder. There is an external   assignments and functional pin descriptions are provided in

MIPI select pin that enables how the switch responds to power       Table 1.

              Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

              202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                   1
DATA SHEET        •  SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

                                         TRX8                TRX9       TRX10  TRX11  TRX12     TRX1  TRX2    TRX14

                                         20                  19         18     17     16     15       14      13

                                   GND   21                                                                   12           SCLK

                                   TXHB  22                                                                   11           SDATA

                                   TXLB  23                                                                   10           VIO

                                   GND   24                                                                      9         VDD

                                         1                   2          3      4      5         6     7          8

                                         ANT                 TRX7       TRX6   TRX5   TRX4      TRX3  TRX13   MIPI_SELECT

                                                                                                                           202826-002

                                                                 Figure 2. SKY13492-21                Pinout

                                                                                  (Top View)

Table   1.  SKY13492-21 Signal Descriptions1 (1 of 2)

   Pin      Name                   Description                                               Pin           Name                               Description

                                                                                                                           MIPI interface select. When this pin is grounded, the

                                                                                                                           switch responds to any of the power mode triggers.

   1        ANT      Antenna port                                                            8        MIPI_SELECT          When this pin is left open, the switch is RFFE MIPI

                                                                                                                           compliant and responds to individual power mode

                                                                                                                           triggers.

                     3G WCDMA transmit/receive port 7. This pin is either                    9

   2        TRX7     connected directly to or disconnected from pin 1,                                VDD                  DC power supply

                     depending on the applied control data.

                     3G WCDMA transmit/receive port 6. This pin is either                    10

   3        TRX6     connected directly to or disconnected from pin 1,                                VIO                  MIPI decoder enable/reference voltage

                     depending on the applied control data.

                     3G WCDMA transmit/receive port 5. This pin is either                    11

   4        TRX5     connected directly to or disconnected from pin 1,                                SDATA                Data input/output

                     depending on the applied control data.

                     3G WCDMA transmit/receive port 4. This pin is either                    12

   5        TRX4     connected directly to or disconnected from pin 1,                                SCLK                 Clock signal

                     depending on the applied control data.

                     Ultra low-loss 3G WCDMA transmit/receive port 3. This pin                                             3G WCDMA transmit/receive port 14. This pin is either

   6        TRX3     is either connected directly to or disconnected from pin 1,             13       TRX14                connected directly to or disconnected from pin 1,

                     depending on the applied control data.                                                                depending on the applied control data.

                     3G WCDMA transmit/receive port 13. This pin is either                                                 Ultra low-loss 3G WCDMA transmit/receive port 2. This

   7        TRX13    connected directly to or disconnected from pin 1,                       14       TRX2                 pin is either connected directly to or disconnected from

                     depending on the applied control data.                                                                pin 1, depending on the applied control data.

                     Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

2                    November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                                       DATA  SHEET  •  SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 1. SKY13492-21 Signal Descriptions1 (2 of 2)

   Pin       Name                                      Description           Pin       Name                       Description

                    Ultra low-loss 3G WCDMA transmit/receive port 1.                              3G WCDMA transmit/receive port 8. This pin is either

   15        TRX1   This pin is either connected directly to or              20        TRX8       connected directly to or disconnected from pin 1,

                    disconnected from pin 1, depending on the applied                             depending on the applied control data.

                    control data.

                    3G WCDMA transmit/receive port 12. This pin is

   16        TRX12  either connected directly to or disconnected from        21        GND        Ground

                    pin 1, depending on the applied control data.

                    3G WCDMA transmit/receive port 11. This pin is                                GSM transmit high band. This pin is either connected

   17        TRX11  either connected directly to or disconnected from        22        TXHB       directly to or disconnected from pin 1, depending on

                    pin 1, depending on the applied control data.                                 the applied control data.

                    3G WCDMA transmit/receive port 10. This pin is                                GSM transmit low band. This pin is either connected

   18        TRX10  either connected directly to or disconnected from        23        TXLB       directly to or disconnected from pin 1, depending on

                    pin 1, depending on the applied control data.                                 the applied control data.

                    3G WCDMA transmit/receive port 9. This pin is either

   19        TRX9   connected directly to or disconnected from pin 1,        24        GND        Ground

                    depending on the applied control data.

1  Bottom ground paddles must be connected to ground.

Electrical and Mechanical Specifications

The absolute maximum ratings of the SKY13492-21 are provided                 The resulting third order intermodulation distortion (IMD3), fRX, is

in Table 2. Electrical specifications are provided in Tables 3 and 4.        measured over all phases of fFUND. The SKY13492-21 exhibits

IMD2 and IMD3 test conditions for various frequencies are listed             exceptional performance for all TRXx ports.

in Tables 5 and 6, respectively.                                             Table 8 shows the isolation matrix for "On" to "Off" arms. Table 9

Triple beat ratio (TBR) test conditions for bands 2 and 5 are listed         shows the isolation matrix for "Ant” to "Off" arms. Table 10

in Table 7.                                                                  provides the matrix of insertion loss and return loss information.

Figure 3 shows a timing diagram. Figure 4 illustrates the test               Table 11 describes the register content and programming

setup used to measure intermodulation products. This industry                read/write sequences. Refer to the MIPI Alliance Specification for

standardized test is used to simulate the WCDMA Band 1 linearity             RF Front–End Control Interface (RFFE), v1.10 (26 July 2011) for

of the antenna switch. A +20 dBm continuous wave (CW) signal,                additional information on MIPI programming sequences and MIPI

fFUND, is sequentially applied to the TRX1 through TRX14 ports,              bus specifications.

while a –15 dBm CW blocker signal, fBLK, is applied to the ANT               Figures 5 and 6 provide the timing diagrams for register write

port.                                                                        commands and read commands, respectively.

                                                                             Table 12 provides the Register_0 logic. Table 13 describes the

                                                                             register parameters and bit values.

                    Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                    202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016  3
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 2. SKY13492-21 Absolute Maximum Ratings1

                                   Parameter                                                    Symbol                            Minimum           Maximum          Units

      Supply voltage                                                                      VDD                                     2.5               6.0                                         V

      MIPI decoder enable/reference voltage                                               VIO                                                       2                                           V

      Clock signal voltage                                                                SCLK                                                      VIO                                         V

      Data signal voltage                                                                 SDATA                                                     VIO                                         V

      RF input power:                                                                     PIN

      LTX pin                                                                                                                                       +36              dBm

      HTX pin                                                                                                                                       +34              dBm

      All TRXx pins2                                                                                                                                +31              dBm

      Storage temperature                                                                 TSTG                                    –55               +150             C

      Operating temperature                                                               TOP                                     –30               +90              C

   1  Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters

      set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.

   2  RF input power for TRXx pins is evaluated with 25% duty cycle rectangular pulse wave.

   ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.

                            This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce

                            potentials of several kilovolts on the human body or equipment, which can discharge without detection.

                            Industry-standard ESD handling precautions should be used at all times.

Table 3. SKY13492-21 DC Electrical Specifications1

(VDD = 2.85 V, TOP = +25 C, Characteristic Impedance                            [ZO]  =  50 Ω, Unless    Otherwise Noted)

                      Parameter                    Symbol                                 Test Condition                          Min      Typical           Max                                Units

      Supply voltage                          VDD                                                                                 2.50     2.85              6.00                                  V

      Supply current, active mode             IDD                                                                                          45                85                                    μA

      Interface supply voltage                VIO                                                                                 1.65     1.80              1.95                                  V

      Interface signal:                       SDATA

      High                                                                                                0.8 × VIO                                                                                V

      Low                                                                                                                                                 0.2 × VIO                                V

      Control current:

      High                                                                                                                                 1                 5                                     μA

      Low                                                                                                                                  1                 5                                     μA

   1  Performance is guaranteed only under the conditions listed in this table.

                         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

4                           November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                                  DATA SHEET • SKY13492-21:  SP16T  ANTENNA  SWITCH                                          WITH  MIPI  INTERFACE

Table 4. SKY13492-21 RF Electrical Specifications1 (1 of 2)

(VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise  Noted)

                Parameter                Symbol              Test Condition          Min            Typical                                                  Max         Units

Operating frequency                   f                                              0.7                                                                     2.7         GHz

Insertion loss                        IL         TXLB, 824 to 915 MHz                               1.35                                                     1.50        dB

                                                 TXHB, 1710 to 1910 MHz                             1.25                                                     1.40        dB

                                                 TRX1 to TRX14 ports (except TRX7):

                                                 700 to 824 MHz                                     0.55                                                     0.80        dB

                                                 824 to 960 MHz                                     0.65                                                     0.90        dB

                                                 1710 to 1990 MHz                                   0.80                                                     0.95        dB

                                                 TRX4 to TRX14 ports (except TRX7):

                                                 2110 to 2170 MHz                                   0.90                                                     1.05        dB

                                                 2300 to 2690 MHz                                   0.90                                                     1.15        dB

                                                 TRX1/2/3 ports:

                                                 2110 to 2170 MHz                                   0.80                                                     1.00        dB

                                                 2300 to 2690 MHz                                   0.90                                                     1.10        dB

                                                 TRX7 port:

                                                 824 to 960 MHz                                     0.70                                                     0.90        dB

                                                 1710 to 1990 MHz                                   0.90                                                     1.05        dB

                                                 2110 to 2170 MHz                                   1.15                                                     1.25        dB

                                                 2300 to 2690 MHz                                   1.15                                                     1.25        dB

GSM LB TX:

2f0 attenuation                       H2LB       2f0 attenuation 1830 MHz            22             24                                                                   dB

3f0 attenuation                       H3LB       3f0 attenuation 2745 MHz            23             27                                                                   dB

4f0 attenuation                       H4LB       4f0 attenuation 3660 MHz            30             35                                                                   dB

GSM HB TX:

2f0 attenuation                       H2HB       2f0 attenuation 3820 MHz            20             22                                                                   dB

3f0 attenuation                       H3HB       3f0 attenuation 5730 MHz            17             19                                                                   dB

Isolation (TRXx to any off TRXx port  Iso

[non-adjacent ports])                            824 to 1910 MHz                     25             28                                                                   dB

(See Table 8 for full matrix)                    1910 to 2690 MHz                    20             23                                                                   dB

Isolation (TRXx to any off TRXx port  Iso

[adjacent ports])                                824 to 1910 MHz                     20             23                                                                   dB

(See Table 8 for full matrix)                    1910 to 2690 MHz                    17             20                                                                   dB

On state match                        Return     0.7 to 2.7 GHz                      14             18                                                                   dB

                                      Loss

GSM harmonics:                        2fo, 3fo

High band                                        PIN = +33 dBm, 50 Ω                                –51                                                      –48         dBm

                                                 PIN = +33 dBm, 3:1 VSWR                            –36                                                                  dBm

Low band                                         PIN = +35 dBm, 50 Ω                                –60                                                      –55         dBm

                                                 PIN = +35 dBm, 3:1 VSWR                            –36                                                                  dBm

TRXx harmonics                        2fo, 3fo   PIN = +25 dBm, 50 Ω,

                                                 f = 704 to 2700 MHz                                –63                                                      –59         dBm

                                                 PIN = +25 dBm,

                                                 5:1 VSWR,

                                                 f = 704 to 2700 MHz                                                                                         –40         dBm

                   Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                     202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                     5
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 4. SKY13492-21 RF Electrical Specifications1 (2 of 2)

(VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise                             Noted)

                  Parameter                       Symbol                                Test Condition                Min               Typical                   Max           Units

      TRX1 through TRX14, band 13 2nd             2fo           PIN = +25 dBm,

      harmonics                                                 f = 787 MHz                                                                                       –78           dBm

      Second order intermodulation distortion     IMD2          See test conditions in Table 5                                          –104                      –102          dBm

      Third order intermodulation distortion      IMD3          See test conditions in Table 6                                          –110                      –105          dBm

      Triple beat ratio:                          TBR           See test conditions in Table 7

      650 to 900 MHz                                                                                                  +81                                                       dBc

      1710 to 2155 MHz                                                                                                +81                                                       dBc

      Turn–on time (see Figure 3)                 tON           From application of VDD and VIO                                                                   20            μs

      Switching speed (see Figure 3)              tS            Port to port                                                                2                     5             μs

   1  Performance is guaranteed only under the conditions listed in this table.

Table  5.   IMD2  Test    Conditions

                                       Transmit                                         Frequency Blocker,  Frequency Blocker,

                                       Frequency         Transmit Power                       Low                     High           Power Blocker                Receive Frequency

            Band                       (MHz)                    (dBm)                         (MHz)                   (MHz)                 (dBm)                       (MHz)

            1                          1950.0                                                 190                     4090                                              2140.0

            2                          1880.0                                                 80                      3840                                              1960.0

            4                          1732.0                                                 400                     3864                                              2132.0

                                                                +20                                                                            –15

            5                          836.5                                                  45                      1718                                              881.5

            7                          2535.0                                                 120                     5187                                              2655.0

            8                          897.0                                                  45                      1839                                              942.0

Table  6.   IMD3  Test    Conditions

                                   Transmit Frequency           Transmit Power                     Frequency Blocker         Power Blocker                        Receive Frequency

            Band                       (MHz)                                     (dBm)                  (MHz)                   (dBm)                                   (MHz)

            1                          1950.0                                                           1760.0                                                          2140.0

            2                          1880.0                                                           1800.0                                                          1960.0

            4                          1732.0                                                           1332.0                                                          2132.0

                                                                                 +20                                                 –15

            5                          836.5                                                            791.5                                                           881.5

            7                          2535.0                                                           2415.0                                                          2655.0

            8                          897.0                                                            852.0                                                           942.0

Table 7. Triple Beat Ratio Test Conditions

                          Transmit                                               Transmit                                    Frequency              Power               TBR Product

                          Frequency 1         Transmit Power 1                   Frequency 2       Transmit Power 2          Blocker @ ANT          Blocker             Frequency

      Band                (MHz)                   (dBm)                          (MHz)                  (dBm)                (MHz)                  (dBm)               (MHz)

       2                  1880.0                                                 1881.0                                      1960.0                                     1960.0 ± 1

                                                  +21.5                                                 +21.5                                       –30

       5                  836.5                                                       837.5                                  881.5                                      881.5 ± 1

                          Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

6                         November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                              DATA SHEET    •  SKY13492-21: SP16T ANTENNA SWITCH                        WITH  MIPI  INTERFACE

VDD (V)

Final VDD                                                                                              VDD

50% of final VDD

                                                                                                             Time (μs)

VIO (V) – Interface Supply                                                     Rising edge of last clock

SCLK (V) – Interface Signal                                                    signal that sets the switch

                                                                               into the desired state

                                                                                                       VIO

                                                                                                       SCLK

                                                                                                             Time (μs)

POUT (dBm)

                                                                                                       POUT

90% of POUT

                                                                                                            Time (μs)

                                                                               Switching Time

Switching Time (tSW) is measured from the                                      tsw < 5 μs

rising edge of the last clock signal to 90% of RF power.

Turn-on Time (tON) is measured from 50%                       Turn-on Time

of final VDD supply voltage to 90% of RF power.                tON ~ 20 μs                                    202826-003

                                                Figure    3.  SKY13492-21. Timing Diagram

Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016              7
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 8.  SKY13492-21:  Isolation Matrix: Isolation “On” Arms  to “Off”  Arms (1 of 2)

“On”      Freq                                                           Isolation (dB)

Arms      (MHz)  LTX    HTX  TRX1  TRX2  TRX3  TRX4            TRX5      TRX6  TRX7      TRX8  TRX9  TRX10  TRX11                                        TRX12  TRX13  TRX14

LTX       915           –31  –52   –51   –46   –42             –45       –45   –41       –46   –49   –51    –51                                          –52    –55    –54

LTX       1910          –26  –51   –52   –43   –42             –47       –43   –37       –37   –41   –44    –45                                          –49    –53    –46

LTX       2690          –16  –47   –48   –42   –41             –42       –39   –34       –33   –37   –40    –41                                          –44    –48    –44

HTX       915    –33         –48   –46   –53   –53             –53       –51   –46       –37   –41   –44    –57                                          –53    –50    –52

HTX       1910   –23         –42   –38   –45   –45             –45       –43   –37       –32   –36   –38    –47                                          –53    –42    –43

HTX       2690   –17         –49   –40   –49   –49             –49       –48   –47       –33   –38   –41    –33                                          –39    –52    –47

TRX1      915    –35    –50        –29   –52   –54             –55       –53   –49       –54   –49   –46    –43                                          –34    –39    –50

TRX1      1910   –34    –33        –22   –42   –43             –43       –42   –38       –42   –41   –39    –36                                          –27    –31    –41

TRX1      2690   –28    –30        –19   –38   –39             –38       –38   –34       –37   –37   –35    –32                                          –24    –27    –37

TRX2      915    –35    –55  –37         –51   –53             –54       –53   –49       –55   –51   –49    –48                                          –40    –36    –48

TRX2      1910   –34    –34  –29         –41   –43             –42       –42   –37       –43   –42   –41    –39                                          –32    –28    –39

TRX2      2690   –28    –31  –26         –37   –38             –38       –37   –34       –37   –38   –37    –35                                          –28    –24    –36

TRX3      915    –33    –54  –55   –52         –29             –37       –42   –45       –57   –58   –59    –58                                          –57    –48    –36

TRX3      1910   –31    –35  –47   –44         –23             –31       –35   –34       –44   –46   –48    –46                                          –47    –39    –29

TRX3      2690   –27    –32  –42   –39         –20             –28       –32   –31       –38   –41   –43    –41                                          –41    –35    –25

TRX4      915    –32    –51  –55   –52   –34                   –29       –38   –43       –57   –58   –59    –57                                          –56    –49    –39

TRX4      1910   –31    –35  –46   –43   –28                   –23       –31   –33       –44   –46   –47    –45                                          –46    –40    –32

TRX4      2690   –27    –32  –41   –38   –25                   –20       –28   –29       –38   –41   –43    –40                                          –41    –35    –28

TRX5      915    –33    –48  –54   –52   –41   –34                       –29   –36       –56   –57   –57    –55                                          –55    –50    –46

TRX5      1910   –32    –35  –45   –42   –35   –27                       –22   –28       –44   –46   –47    –45                                          –45    –40    –38

TRX5      2690   –28    –33  –41   –38   –32   –25                       –19   –24       –38   –41   –42    –40                                          –41    –36    –35

TRX6      915    –34    –46  –53   –51   –45   –41             –33             –30       –55   –56   –55    –54                                          –54    –50    –48

TRX6      1910   –35    –35  –44   –42   –38   –34             –26             –23       –43   –45   –46    –43                                          –44    –40    –40

TRX6      2690   –30    –34  –40   –37   –34   –31             –23             –19       –37   –40   –41    –39                                          –40    –36    –36

TRX7      915    –35    –44  –52   –51   –47   –45             –39       –36             –53   –54   –54    –52                                          –52    –51    –49

TRX7      1910   –39    –36  –43   –41   –39   –37             –31       –29             –41   –44   –44    –42                                          –43    –40    –40

TRX7      2690   –31    –36  –39   –36   –35   –33             –27       –25             –36   –39   –40    –38                                          –39    –35    –36

TRX8      915    –34    –42  –46   –47   –54   –55             –56       –54   –49             –30   –35    –38                                          –43    –50    –52

TRX8      1910   –46    –35  –39   –39   –44   –44             –44       –43   –37             –23   –28    –31                                          –37    –40    –42

TRX8      2690   –32    –34  –36   –35   –39   –39             –40       –39   –34             –20   –25    –27                                          –34    –36    –38

TRX9      915    –34    –45  –44   –46   –54   –56             –56       –53   –49       –38         –28    –35                                          –41    –50    –52

TRX9      1910   –40    –37  –38   –38   –44   –44             –44       –43   –38       –30         –22    –28                                          –35    –40    –43

TRX9      2690   –32    –44  –34   –34   –39   –40             –40       –39   –34       –26         –19    –25                                          –32    –36    –38

TRX10     915    –34    –46  –42   –45   –54   –56             –55       –53   –49       –40   –33          –29                                          –37    –49    –52

TRX10     1910   –37    –35  –36   –37   –44   –44             –44       –43   –38       –32   –27          –23                                          –32    –40    –42

TRX10     2690   –31    –34  –33   –33   –39   –40             –39       –39   –34       –28   –24          –20                                          –29    –36    –38

                 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

8                November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                               DATA SHEET • SKY13492-21: SP16T       ANTENNA SWITCH WITH                                        MIPI INTERFACE

Table 8.  SKY13492-21:  Isolation Matrix: Isolation “On” Arms  to “Off”  Arms (2 of 2)

“On”      Freq                                                           Isolation (dB)

Arms      (MHz)  LTX    HTX  TRX1  TRX2  TRX3  TRX4            TRX5      TRX6  TRX7      TRX8  TRX9  TRX10  TRX11                                        TRX12  TRX13  TRX14

TRX11     915    –34    –47  –38   –42   –54   –55             –55       –53   –49       –43   –39   –34                                                 –30    –48    –52

TRX11     1910   –35    –33  –32   –35   –44   –44             –44       –43   –38       –34   –32   –28                                                 –24    –39    –42

TRX11     2690   –30    –30  –29   –32   –39   –39             –39       –38   –34       –30   –28   –25                                                 –21    –36    –38

TRX12     915    –34    –48  –29   –35   –53   –55             –55       –54   –49       –52   –46   –42    –36                                                 –40    –51

TRX12     1910   –35    –33  –23   –27   –43   –44             –44       –43   –38       –41   –39   –36    –29                                                 –31    –41

TRX12     2690   –29    –30  –19   –24   –39   –39             –39       –38   –34       –36   –35   –33    –26                                                 –27    –38

TRX13     915    –48    –72  –58   –54   –31   –37             –44       –49   –53       –65   –65   –64    –63                                          –61           –46

TRX13     1910   –47    –63  –55   –51   –28   –33             –40       –46   –50       –63   –62   –61    –60                                          –58           –38

TRX13     2690   –45    –54  –55   –53   –27   –31             –38       –44   –48       –60   –60   –59    –59                                          –57           –34

TRX14     915    –61    –61  –33   –17   –53   –57             –60       –63   –65       –59   –56   –51    –44                                          –39    –46

TRX14     1910   –56    –47  –29   –13   –51   –54             –58       –61   –64       –57   –53   –48    –41                                          –36    –39

TRX14     2690   –52    –44  –27   –10   –48   –52             –56       –60   –63       –56   –52   –47    –39                                          –34    –34

Table 9. SKY13492-21 Isolation Matrix: Isolation "Ant" to "Off" Arms (1 of 2)

(VDD = 2.85 V, TOP=+25 °C, Characteristic Impedance [Z0] = 50 Ω, Unless Otherwise Noted)

“On”      Freq                                                           Isolation (dB)

Arms      (MHz)  LTX    HTX  TRX1  TRX2  TRX3  TRX4            TRX5      TRX6  TRX7      TRX8  TRX9  TRX10  TRX11                                        TRX12  TRX13  TRX14

LTX       915           –33  –48   –48   –40   –38             –40       –39   –34       –42   –44   –46    –47                                          –48    –43    –47

LTX       1910          –45  –54   –54   –45   –41             –35       –35   –32       –44   –46   –49    –51                                          –53    –48    –51

LTX       2690          –38  –45   –42   –43   –39             –34       –34   –32       –43   –44   –45    –44                                          –44    –45    –42

HTX       915    –40         –50   –49   –46   –45             –43       –42   –38       –42   –47   –49    –43                                          –46    –48    –47

HTX       1910   –24         –42   –40   –39   –38             –36       –35   –32       –32   –37   –38    –36                                          –39    –40    –39

HTX       2690   –21         –39   –36   –36   –34             –33       –32   –31       –29   –34   –35    –36                                          –39    –38    –36

TRX1      915    –38    –35        –36   –48   –45             –44       –44   –39       –46   –51   –54    –51                                          –44    –50    –40

TRX1      1910   –34    –31        –30   –41   –39             –38       –37   –33       –39   –42   –43    –39                                          –32    –42    –30

TRX1      2690   –28    –32        –25   –38   –36             –36       –35   –30       –35   –38   –39    –35                                          –28    –39    –25

TRX2      915    –38    –34  –43         –48   –46             –45       –44   –39       –46   –50   –53    –50                                          –45    –52    –42

TRX2      1910   –34    –30  –32         –41   –39             –39       –38   –33       –39   –42   –43    –39                                          –35    –43    –31

TRX2      2690   –29    –34  –28         –38   –36             –36       –35   –29       –35   –38   –40    –35                                          –31    –39    –26

TRX3      915    –36    –36  –49   –49         –35             –43       –48   –41       –45   –47   –47    –47                                          –47    –44    –52

TRX3      1910   –32    –32  –41   –38         –29             –36       –37   –32       –38   –41   –41    –40                                          –40    –31    –40

TRX3      2690   –27    –36  –38   –35         –24             –31       –32   –28       –35   –38   –38    –36                                          –37    –27    –37

TRX4      915    –36    –37  –49   –49   –45                   –33       –43   –41       –45   –47   –47    –47                                          –48    –46    –51

TRX4      1910   –31    –33  –41   –39   –33                   –28       –35   –32       –38   –41   –41    –40                                          –41    –34    –40

TRX4      2690   –27    –37  –38   –36   –28                   –24       –30   –28       –35   –38   –38    –36                                          –37    –30    –36

TRX5      915    –38    –37  –50   –49   –50   –42                       –35   –40       –45   –47   –48    –48                                          –49    –52    –51

TRX5      1910   –32    –33  –42   –40   –39   –33                       –29   –30       –38   –41   –41    –40                                          –41    –41    –40

TRX5      2690   –27    –40  –39   –36   –35   –29                       –24   –26       –35   –37   –38    –37                                          –38    –36    –36

                 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                 202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                     9
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 9. SKY13492-21 Isolation Matrix: Isolation "Ant" to "Off" Arms (2 of 2)

(VDD = 2.85 V, TOP=+25 °C, Characteristic Impedance [Z0] = 50 Ω, Unless Otherwise Noted)

“On”   Freq                                                         Isolation (dB)

Arms   (MHz)  LTX  HTX  TRX1  TRX2  TRX3  TRX4  TRX5  TRX6                     TRX7  TRX8  TRX9  TRX10  TRX11                                         TRX12  TRX13  TRX14

TRX6   915    –40  –38  –50   –49   –52   –50   –44                            –37   –46   –48   –48    –48                                           –50    –51    –51

TRX6   1910   –34  –34  –42   –40   –41   –39   –32                            –28   –39   –41   –41    –41                                           –42    –41    –40

TRX6   2690   –28  –43  –39   –36   –37   –34   –28                            –22   –35   –37   –38    –37                                           –38    –37    –36

TRX7   915    –43  –39  –51   –50   –51   –51   –45   –42                            –47   –49   –49    –49                                           –50    –51    –50

TRX7   1910   –37  –34  –42   –40   –41   –39   –34   –31                            –39   –41   –42    –41                                           –42    –41    –40

TRX7   2690   –29  –45  –38   –36   –36   –35   –30   –27                            –34   –37   –38    –37                                           –38    –36    –35

TRX8   915    –40  –33  –57   –53   –47   –45   –43   –43                      –39         –36   –45    –49                                           –54    –49    –50

TRX8   1910   –37  –28  –45   –42   –40   –38   –37   –36                      –32         –31   –37    –37                                           –44    –41    –39

TRX8   2690   –28  –27  –40   –37   –36   –35   –34   –33                      –30         –26   –31    –31                                           –39    –37    –35

TRX9   915    –39  –35  –55   –53   –47   –45   –43   –43                      –39   –41         –34    –45                                           –49    –49    –50

TRX9   1910   –36  –32  –45   –42   –40   –38   –37   –36                      –32   –31         –29    –36                                           –42    –41    –39

TRX9   2690   –29  –37  –39   –37   –37   –35   –34   –34                      –30   –26         –24    –31                                           –37    –37    –35

TRX10  915    –39  –36  –50   –53   –47   –45   –43   –43                      –39   –43   –45          –35                                           –43    –49    –50

TRX10  1910   –35  –32  –43   –42   –40   –38   –37   –36                      –32   –33   –33          –30                                           –38    –41    –39

TRX10  2690   –29  –41  –38   –38   –37   –35   –34   –34                      –30   –29   –29          –26                                           –34    –38    –34

TRX11  915    –38  –35  –43   –50   –47   –45   –43   –43                      –39   –42   –47   –46                                                  –34    –49    –49

TRX11  1910   –35  –32  –38   –42   –40   –38   –37   –37                      –32   –33   –36   –35                                                  –29    –41    –39

TRX11  2690   –29  –36  –34   –37   –37   –35   –34   –34                      –30   –29   –32   –30                                                  –25    –38    –34

TRX12  915    –38  –35  –35   –45   –47   –45   –44   –43                      –39   –47   –53   –51    –44                                                  –49    –41

TRX12  1910   –34  –32  –30   –34   –40   –38   –38   –37                      –33   –39   –42   –42    –35                                                  –42    –31

TRX12  2690   –28  –32  –25   –29   –37   –36   –35   –35                      –30   –35   –38   –37    –31                                                  –38    –26

TRX13  915    –37  –33  –46   –44   –50   –46   –45   –44                      –39   –46   –49   –51    –49                                           –44           –49

TRX13  1910   –34  –29  –36   –33   –42   –39   –39   –38                      –33   –39   –41   –42    –39                                           –35           –42

TRX13  2690   –29  –33  –31   –28   –38   –36   –35   –34                      –29   –35   –38   –39    –35                                           –30           –38

TRX14  915    –37  –36  –49   –49   –35   –45   –49   –48                      –40   –45   –47   –47    –46                                           –47    –41

TRX14  1910   –33  –32  –40   –37   –29   –35   –39   –38                      –32   –38   –41   –41    –39                                           –40    –31

TRX14  2690   –28  –35  –37   –34   –24   –29   –34   –33                      –28   –35   –38   –38    –36                                           –37    –26

              Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

10            November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                              DATA SHEET • SKY13492-21: SP16T         ANTENNA  SWITCH                                    WITH MIPI  INTERFACE

Table 10. SKY13492-21: Insertion loss and Return loss Matrix  (1  of 2)

(VDD = 2.85 V, TOP=+25 °C, Characteristic Impedance [Z0]=50   Ω,  Unless  Otherwise  Noted)

       ON_Throw        freq_MHz                                   IL                         RL_Pole                                                     RL_Throw

TXLB             915                                              –1.4                       –13.7                                                       –15.2

TXLB             1910                                             –23.6                      –1.5                                                        –0.2

TXLB             2690                                             –25.2                      –2.2                                                        –0.6

TXHB             915                                              –0.8                       –30.3                                                       –19.1

TXHB             1910                                             –1.3                       –16.7                                                       –17.0

TXHB             2690                                             –9.2                       –3.3                                                        –1.6

TRX1             915                                              –0.6                       –24.3                                                       –22.2

TRX1             1910                                             –0.7                       –20.7                                                       –23.4

TRX1             2690                                             –0.9                       –22.3                                                       –16.8

TRX2             915                                              –0.6                       –22.3                                                       –20.7

TRX2             1910                                             –0.7                       –23.3                                                       –26.9

TRX2             2690                                             –0.9                       –20.5                                                       –16.4

TRX3             915                                              –0.6                       –22.2                                                       –21.1

TRX3             1910                                             –0.7                       –22.6                                                       –24.8

TRX3             2690                                             –0.9                       –22.4                                                       –17.1

TRX4             915                                              –0.6                       –23.3                                                       –22.7

TRX4             1910                                             –0.7                       –20.3                                                       –22.4

TRX4             2690                                             –0.9                       –26.7                                                       –18.7

TRX5             915                                              –0.6                       –26.7                                                       –26.1

TRX5             1910                                             –0.7                       –17.8                                                       –20.1

TRX5             2690                                             –0.8                       –33.9                                                       –22.2

TRX6             915                                              –0.6                       –26.8                                                       –27.5

TRX6             1910                                             –0.7                       –16.0                                                       –17.7

TRX6             2690                                             –0.9                       –22.6                                                       –22.4

TRX7             915                                              –0.6                       –27.3                                                       –26.9

TRX7             1910                                             –0.8                       –13.9                                                       –15.3

TRX7             2690                                             –1.0                       –15.6                                                       –17.0

TRX8             915                                              –0.6                       –27.1                                                       –24.0

TRX8             1910                                             –0.7                       –17.5                                                       –20.0

TRX8             2690                                             –0.9                       –32.8                                                       –22.4

TRX9             915                                              –0.6                       –27.3                                                       –24.3

TRX9             1910                                             –0.7                       –17.3                                                       –19.2

TRX9             2690                                             –0.9                       –30.1                                                       –21.3

TRX10            915                                              –0.6                       –26.8                                                       –24.6

TRX10            1910                                             –0.7                       –17.6                                                       –19.8

TRX10            2690                                             –0.9                       –26.0                                                       –19.8

       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                 202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016             11
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 10. SKY13492-21: Insertion loss and Return loss Matrix  (2  of 2)

(VDD = 2.85 V, TOP=+25 °C, Characteristic Impedance [Z0]=50   Ω,  Unless  Otherwise  Noted)

       ON_Throw        freq_MHz                                   IL                         RL_Pole                                                     RL_Throw

TRX11            915                                              –0.6                       –26.7                                                       –24.5

TRX11            1910                                             –0.7                       –18.5                                                       –21.1

TRX11            2690                                             –0.9                       –28.1                                                       –20.4

TRX12            915                                              –0.6                       –24.9                                                       –23.2

TRX12            1910                                             –0.7                       –19.8                                                       –22.6

TRX12            2690                                             –0.9                       –24.4                                                       –18.2

TRX13            915                                              –0.6                       –20.7                                                       –21.0

TRX13            1910                                             –0.7                       –24.4                                                       –26.3

TRX13            2690                                             –0.9                       –19.9                                                       –16.7

TRX14            915                                              –0.6                       –20.5                                                       –20.1

TRX14            1910                                             –0.7                       –24.9                                                       –31.5

TRX14            2690                                             –0.9                       –20.0                                                       –17.2

       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

12               November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                                           DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI                                          INTERFACE

                                                                                                            fBLK                  fFUND        fRX

                                                                                                     1760 MHz,              1950 MHz,     2140 MHz,

                                                                                                     –15 dBm                +20 dBm       Measure Tone

                                                        Circulator

                              Signal Generator                      Coupler to Monitor          1950 MHz

                              fFUND = 1950 MHz,                     Input Power                 Bandpass Filter

                              +20 dBm

                                                                                                Circulator

                                                                    SKY13492                                      1760 MHz                Signal Generator

                              Duplexer               Phase Shifter  fFUND = +20 dBm                              Bandpass Filter          fBLK = 1760 MHz,

                                                                    fBLK = –15 dBm                                                        –15 dBm

                              Spectrum Analyzer

                              fRX = 2140 MHz

                                                                                                                                                    S3437

                                                        Figure 4.   Third Order Intermodulation Test Setup

Table 11. Command Sequence Bit Definitions

                                                                                                                                          Extended Operation

                        C11–                                                            Parity                   DA7(1)–          Parity                    DA7(n)–  Parity

Type     SSC            C8    C7                 C6–C5  C4          C3–C0               Bits    BPC              DA0(1)           Bits    BPC               DA0(n)   Bits    BPC

Reg0     Y    SA[3:0]         1         Data[6:5]       Data[4]     Data{3:0]           Y       Y                 –               –       –                 –        –       –

Write

Reg      Y    SA[3:0]         0                  10     Addr[4]     Addr[3:0]           Y       –                Data[7:0]        –       –                 –        Y       Y

Write

Reg      Y    SA[3:0]         0                  11     Addr[4]     Addr[3:0]           Y       Y                Data[7:0]        –       –                 –        Y       Y

Read

Legend:

SSC = Sequence start command  DA = Data/address frame bits          BC = Byte count (# of consecutive addresses)

C = Command frame bits        BPC = Bus park cycle

              Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

              202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                              13
DATA  SHEET  •  SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

      SCLK

      SDATA                                      SA3        SA2      SA1      SA0      0          1         0            A4      A3      A2           A1        A0  P

                SSC                                                                      Example Register Write Command Frame

                SCLK

                SDATA                      P          D7         D6       D5       D4        D3         D2        D1         D0      P       0

                                                                              Example Data Frame                                             Bus

                                                                                                                                             Park

             Signal Driven by Master

             Signal Not Driven; Pull-Down     Only

             For Reference Only                                                                                                                                 202826-005

                                                            Figure 5. Register Write Command Timing Diagram

      SCLK

      SDATA                                      SA3        SA2      SA1      SA0         0          1         1         A4      A3      A2           A1        A0          P

                       SSC                                                                Example Register Read Command Frame

                SCLK

                SDATA                         P       0          D7       D6       D5        D4         D3           D2      D1      D0            P      0

                                                      Bus                                        Example Data Frame                                       Bus

                                                      Park                                                                                                Park

            Signal Driven by Master

            Signal Not Driven; Pull-Down Only

            Signal Driven by Slave

            For Reference Only                                                                                                                                  202826-006

                                                            Figure 6.  Register    Read   Command Timing Diagram

                Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com                         • www.skyworksinc.com

14              November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change        Without Notice • 202826F
                                                  DATA                    SHEET   •  SKY13492-21: SP16T ANTENNA SWITCH WITH                        MIPI  INTERFACE

Table 12. Register_0 Truth Table

                                                                                     Register_0 Bits

       Antenna Path               Bit[7]  Bit[6]                          Bit[5]     Bit[4]  Bit[3]   Bit[2]  Bit[1]                                     Bit[0]

Sleep mode (standby)              X       0                               0          0       0        0                                         0        0

2G transmit low band              X       0                               0          0       1        0                                         1        0

2G transmit high band             X       0                               0          0       1        0                                         0        0

TRX1                              X       0                               0          0       0        1                                         0        0

TRX2                              X       0                               0          0       0        1                                         0        1

TRX3                              X       0                               0          0       0        1                                         1        0

TRX4                              X       0                               0          0       0        1                                         1        1

TRX5                              X       0                               0          0       1        0                                         0        1

TRX6                              X       0                               0          0       1        0                                         1        1

TRX7                              X       0                               0          0       1        1                                         0        0

TRX8                              X       0                               0          0       0        0                                         0        1

TRX9                              X       0                               0          0       0        0                                         1        0

TRX10                             X       0                               0          0       0        0                                         1        1

TRX11                             X       0                               0          0       1        1                                         0        1

TRX12                             X       0                               0          0       1        1                                         1        0

TRX13                             X       0                               0          1       0        0                                         0        0

TRX14                             X       0                               0          1       0        0                                         0        1

Isolation mode (warm–up)          X       1                               1          1       1        1                                         1        1

       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781]        376-3100 • sales@skyworksinc.com • www.skyworksinc.com

       202826F • Skyworks Proprietary Information • Products and Product  Information are Subject to Change Without Notice • November 16, 2016                   15
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 13. Register Description  and Programming (1 of 2)

          Register

                    Address                                                                                                                                 Default

    Name            (Hex)                 Parameter                                      Description                                                        (Binary)

    Register_0      0000        MODE_CTRL                 Bits[7:0]:                                                                                     –

                                                          Switch control. See Table 8 for logic

                                SOFTWARE RESET            Bit[7]:                                                                                        0

                                                          Resets all data to default values except for USID, GSID, or the

                                                          contents of the PM_TRIG Register.

                                                          0 = Normal operation

                                                          1 = Software reset

                                COMMAND_FRAME_PARITY_ERR  Bit[6]:                                                                                        0

                                                          Command sequence received with parity error – discard command.

                                COMMAND_LENGTH_ERR        Bit[5]:                                                                                        0

                                                          Command length error.

                                ADDRESS_FRAME_PARITY_ERR  Bit[4]:                                                                                        0

    RFFE_STATUS     001A                                  Address frame parity error = 1.

                                DATA_FRAME_PARITY_ERR     Bit[3]:                                                                                        0

                                                          Data frame with parity error.

                                READ_UNUSED_REG           Bit[2]:                                                                                        0

                                                          Read command to an invalid address.

                                WRITE_UNUSED_REG          Bit[1]:                                                                                        0

                                                          Write command to an invalid address.

                                BID_GID_ERR               Bit[0]:                                                                                        0

                                                          Read command with a BROADCAST_ID (refer to the MIPI Alliance

                                                          Specification) or GSID.

                                Reserved                  Bits[7:4]: Reserved                                                                            0000

    GROUP_SID       001B        GSID                      Bits[3:0]:                                                                                     0000

                                                          Group slave ID

                 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

16               November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                                           DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Table 13. Register Description and Programming (2 of 2)

         Register

                             Address                                                                                                                            Default

   Name                      (Hex)               Parameter                                                  Description                                         (Binary)

                                      PWR_MODE                             Bits[7:6]:                                                                       01

                                                                           00 = Normal operation (active)

                                                                           01 = Default settings (startup)

                                                                           10 = Low power (low power)

                                                                           11 = Reserved

                                      Trigger_Mask_2                       Bit[5]:                                                                          0

                                                                           If this bit is set, trigger 2 is disabled. When all triggers are disabled, if

                                                                           writing to a register that is associated with trigger 2, the data goes

                                                                           directly to the destination register.

                                      Trigger_Mask_1                       Bit[4]:                                                                          0

                                                                           If this bit is set, trigger 1 is disabled. When all triggers are disabled, if

                                                                           writing to a register that is associated with trigger 1, the data goes

   PM_TRIG1                  001C                                          directly to the destination register.

                                      Trigger_Mask_0                       Bit[3]:                                                                          0

                                                                           If this bit is set, trigger 0 is disabled. When all triggers are disabled, if

                                                                           writing to a register that is associated with trigger 0, the data goes

                                                                           directly to the destination register.

                                      Trigger_2                            Bit[2]:                                                                          0

                                                                           If this bit is set, data is loaded into the trigger 2 registers.

                                      Trigger_1                            Bit[1]:                                                                          0

                                                                           If this bit is set, data is loaded into the trigger 1 registers

                                                                           (unsupported).

                                      Trigger_0                            Bit[0]:                                                                          0

                                                                           If this bit is set, data is loaded into the trigger 0 registers

                                                                           (unsupported).

   PRODUCT_ID                001D     PRODUCT_ID                           Bits[7:0]:                                                                       01011101

                                                                           This is a read–only register. However, during the programming of the

                                                                           Unique Slave Identifier (USID), a write command sequence is

                                                                           performed on this register but the value is not changed.

   MANUFACTURER_ID           001E     MANUFACTURER_ID                      Bits[7:0]:                                                                       10100101

                                                                           Read–only register

                                      Reserved                             Bits[7:6]:                                                                       00

                                                                           Reserved

                                      MANUFACTURER_ID                      Bits[5:4]:                                                                       01

   MAN_USID                  001F

                                                                           Read–only register

                                      USID                                 Bits[3:0]:                                                                       1011

                                                                           Programmable USID. A write to these bits programs the USID.

1  Unlike the complete independence between triggers 0, 1, and 2, and also between the associated trigger masks 0, 1, and 2, respectively (as described in the MIPI RFFE Specification), when

   pin 7 is grounded, this device uses additional interactions between the provided trigger functions.

   The delayed application of updated data to all triggerable registers in this device may be accomplished using any of the three triggers (0, 1, or 2), provided that the particular trigger used is

   not currently masked off. If multiple triggers are enabled, any or all of those are sufficient to cause the data to be transferred from shadow registers to destination registers for all triggerable

   registers in the device.

   It is also necessary to disable all three triggers (i.e., set all three trigger masks) to ensure that data written to any triggerable register will immediately be written to the destination register at

   the conclusion of the RFFE command sequence where the data is written.

               Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                    202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                                                    17
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Evaluation Board Description                                                                        Package and Handling Information

The SKY13492-21 Evaluation Board is used to test the                                                Since the device package is sensitive to moisture absorption, it is

performance of the SKY13492-21 SP16T Switch. An Evaluation                                          baked and vacuum packed before shipping. Instructions on the

Board schematic diagram is provided in Figure 7. A                                                  shipping container label regarding exposure to moisture after the

recommended ESD protection circuit diagram is provided in                                           container seal is broken must be followed. Otherwise, problems

Figure 8. An assembly drawing for the Evaluation Board is shown                                     related to moisture absorption may occur when the part is

in Figure 9.                                                                                        subjected to high temperature during solder assembly.

                                                                                                    The SKY13492-21 is rated to Moisture Sensitivity Level 3 (MSL3)

Package Dimensions                                                                                  at 260 C. It can be used for lead or lead–free soldering. For

                                                                                                    additional information, refer to the Skyworks Application Note,

The PCB layout footprint for the SKY13492-21 is provided in                                         PCB Design and SMT Assembly/Rework Guidelines for MCM–L

Figure 10. Typical part markings are shown in Figure 11. Package                                    Packages, document number 101752.

dimensions are shown in Figure 12, and tape and reel dimensions                                     Care must be taken when attaching this product, whether it is

are provided in Figure 13.                                                                          done manually or in a production solder reflow environment.

                                                                                                    Production quantities of this product are shipped in a standard

                                                                                                    tape and reel format.

                                   RFC16                                                                                           RFC17

                                                                     24        23            22              21

                                                    Pad                   GND       TXLB            TXHB            GND        20

                            RFC15         1         ANT                                                                  TRX8             RFC8

                                   RFC7   2         TRX7                                                                 TRX9  19  RFC9

                            RFC6          3         TRX6                                                            TRX10      18         RFC10

                                   RFC5   4         TRX5                                                            TRX11      17  RFC11

                            RFC4          5         TRX4                                                            TRX12      16         RFC12

                                   RFC3   6         TRX3                                                                 TRX1  15  RFC1

                                          7                                                                              TRX2  14         RFC2

                            RFC13                   TRX13

                                          8         MIPI_                                 SDATA                     TRX14      13  RFC14

                                                    SELECT           VDD       VIO                           SCLIK

                                                              9           10        11              12

                                                                               C2

                                                                               DNP

                                                      C1

                                                      DNP

                                                           6         5         4          3               2         1

                                                           MIPI_SEL       VDD  VIO           SDATA           SCLK        GND

                                                                               DCH1 Header                                                202826-007

                                          Figure    7. SKY13492-21 Evaluation Board Schematic

              Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

18            November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                          DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH                                                             MIPI  INTERFACE

                          4.7 pF

          To Application                         To SKY13492

          Antenna                                Antenna (Pin 1)

                          18 nH   18 nH

                          ESD Circuit 1

                          12 pF

          To Application                         To SKY13492

          Antenna                                Antenna (Pin 1)

                                         8.2 nH

                          ESD Circuit 2          202826-008

          Figure 8. SKY13492-21 Recommended ESD Protection Circuits

                                                                     202826-009

          Figure 9. SKY13492-21 Evaluation Board Assembly Diagram

Skyworks  Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

202826F   • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016        19
DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

            Stencil aperture size for center                             2X 0.85

            ground pad should be 80% to 100%

            (by area) of the solder mask opening                                             12X 0.5

                                                                                      16X 0.5

                                                                                                       20X     0.2

                                             2.8         2X   0.45

                                                                                      0.4 Pitch

                                                  Pin 24                                              Package

                                                  Pin 1                                               Outline

                                             Pin 1 Indicator             3.6

                                             0.30 x 45°

                                                                    Stencil Aperture

                                                                       Top View

                                                                                      Opening size of               2X   0.85

                                             Thermal Via Array, ø0.3 mm       60 to 100% of exposed

                                             on 0.6 mm pitch improves         center opening shown                             12X                  0.6

            0.6 Pitch                        thermal performance

                                             0.25 Typ                                                                                               16X 0.6

                                                  9X 0.5                                                                                                       20X   0.3

                                                                                      2.9    2X 0.45

                                             15X 0.5                                                                                                0.4 Pitch

                                                              18X 0.2

    2.8                                                                                                                                                  Package

                                             0.4 Pitch                                Pin 24                                                             Outline

                                                                                      Pin 1                         3.7

                                                         Package                     Pin 1 Indicator

    Pin 24  3.6                                          Outline                     0.30 x 45°

Pin 1

            Metallization                                                                              Solder Mask Opening

            Top View                                                                                           Top View

    Notes:

    1.   All dimensions are in millimeters.

    2.   Thermal vias should be resin filled and capped according

            to IPC-4761, Type VII vias. Recommended Cu thickness is 30 to 35 μm.                                                                         202826-010

                                                  Figure 10. SKY13492-21 PCB Layout Footprint

                                                                         (Top View)

            Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

20          November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                                                 DATA SHEET • SKY13492-21: SP16T ANTENNA                      SWITCH           WITH  MIPI    INTERFACE

                                                  Pin 1

                                               Indicator

                                                                                                                Skyworks Part Number

                                                                                 13492                          Lot Code

                                                                           XXXXX                                Date Code:

                                                                                                                   YY = Calendar Year

                                                                                 YYWW                              WW = Week

                                                                                               202826-011

                                                                   Figure  11. Typical Part Markings

                                                                                 (Top View)

                                                                                       Solder  Mask Opening

                                                                                               0.2        A  B  C                        0.2  0.6              1.55

                       3.3                        B                                                                                  1

                                                          C                                                                          4X  4X   4X               4X

                                                                                                                16X       1.15

                                                                                                                             A                                       4X 0.6

Pin 1                                                 2.5                                                                 0

Indicator                                                                                                                                                            4X 0.2

                                                                                                                             B                                       Pin 24

                                                                                                                                                                     Pin 1 Indicator

                                                             0.80  ±  0.1              A                     24X SMT Pad                                             See Detail C

                                                                                                                                         0                           Pin 1

                                   0.15        A  B       C                               0.1                   0.1 M  A  B  C

                       Top View                                            Side  View                                                Bottom View

                                                                                                                                              1.7

                       0.25 ± 0.1                                          0.25 ± 0.1                                                                                Solder Mask

                                                                   (0.1)                                                                                             Edges

                                   Metal Pad

                                   Edge

                                                                                              0.25 ± 0.1                        0.9

           0.2 ± 0.05              0.3 ± 0.05

                                                             Metal Pad                 (0.1)                    5X R0.05     Max.                                    0.3 x 0.3

           (0.1)                                                   Edge

                       Detail A                                            Detail B                                                      Detail C

                       Pad                                                       Pad                                                          Pad

                       Scale: 2X                                           Scale: 2X                                                     Scale: Full

           4X This Rotation                                                1X This Rotation                                              1X This Rotation

           4X Rotated 180°                                                 1X Rotated 180°

           6X Rotated 90° CW                                          1X Rotated 90° CW

           6X Rotated 90° CCW                                      1X Rotated 90° CCW

Notes:

1. All measurements are in millimeters.                                                                                                                                      202826-012

2. Dimensions and tolerances according            to  ASME   Y14.5M-1994.

                                                             Figure 12. SKY13492-21 Package                  Dimensions

                       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                       202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                      21
DATA SHEET    •  SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

                                                                                        4.0  ±  0.10                                                     Pin 1        1.75 ± 0.10  3.50 ± 0.05

                 3.56 ± 0.1 (Bo)                                                                                        2.0 ± 0.05

0.30 Max (T)                               ∅1.5 + 0.1

                                                                                                                                                                                                8.0 + 0.3  –0.1

                 1.24 ± 0.1 (Ko)                                                                4.0 ±  0.10

                                                                      2.79 ± 0.10 (Ao)                                                                          ∅1.0  Min

    Notes:                                                                                                   User Feed

    1. Carrier tape must meet all requirements of Skyworks GP01-D233                                         Direction

              procurement spec for tape and reel shipping.

    2. Carrier tape: black conductive polycarbonate or polystyrene.

    3. Cover tape material: transparent conductive.

    4. ESD-surface resistivity shall be ≤ 1 x 1010 Ω/square per EIA,

              JEDEC TNR Specification.

    5. 10-sprocket hole pitch cumulative tolerance: ±0.20 mm.                                                                                                         202826-013

    6. All dimensions are in millimeters.

                                                     Figure 13. SKY13492-21 Tape and    Reel Dimensions

                 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

22               November 16, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202826F
                                                                                  DATA SHEET • SKY13492-21: SP16T ANTENNA SWITCH WITH MIPI INTERFACE

Ordering Information

                     Model Name                                                   Manufacturing Part Number  Evaluation Board Part Number

SKY13492-21: 0.7 to 2.7 GHz SP16T Antenna Switch                     SKY13492-21                             SKY13492-21-EVB

with MIPI Interface

Copyright © 2013-2016 Skyworks Solutions, Inc. All Rights Reserved.

Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by

Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the

information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to

update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.

No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or

information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions

of Sale.

THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A

PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON–INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY

DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS

SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,

LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE

POSSIBILITY OF SUCH DAMAGE.

Skyworks products are not intended for use in medical, lifesaving or life–sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,

death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any

damages resulting from such improper use or sale.

Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of

products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for

applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.

Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third–party brands and names are for

identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by

reference.

                     Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                     202826F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2016                                           23
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Skyworks:

SKY13492-21
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved