电子工程世界电子工程世界电子工程世界

产品描述

搜索

SKY13385-460LF

器件型号:SKY13385-460LF
器件类别:热门应用    无线/射频/通信   
厂商名称:Skyworks
厂商官网:http://www.skyworksinc.com
下载文档

器件描述

RF Amplifier .05-4GHz SSG 12.9dB NF .8dB GaAs

参数
产品属性属性值
产品种类:
Product Category:
RF Switch ICs
制造商:
Manufacturer:
Skyworks
RoHS:YES
Number of Switches:Triple
Switch Configuration:SP3T
Operating Frequency:100 MHz to 3.5 GHz
Insertion Loss:0.52 dB
Off Isolation - Typ:25 dB
最大工作温度:
Maximum Operating Temperature:
+ 85 C
安装风格:
Mounting Style:
SMD/SMT
封装 / 箱体:
Package / Case:
QFN-12
封装:
Packaging:
Reel
封装:
Packaging:
MouseReel
封装:
Packaging:
Cut Tape
商标:
Brand:
Skyworks Solutions, Inc.
High Control Voltage:1.65 V to 3.465 V
最小工作温度:
Minimum Operating Temperature:
- 40 C
Off Time - Max:190 ns
On Time - Max:250 ns
工厂包装数量:
Factory Pack Quantity:
3000
单位重量:
Unit Weight:
0.000776 oz

SKY13385-460LF器件文档内容

DATA SHEET

SKY13385-460LF: 0.1-3.5 GHz                                   SP3T Switch

Applications

• 802.11 b/g WLANs

• Bluetooth®

Features

• Broadband frequency range: 0.1 to 3.5 GHz

• Low insertion loss: 0.5 dB @ 2.45 GHz

• High isolation: 32 dB up to 2.45 GHz

• No external DC blocking capacitors required

• Positive low voltage control: VCTL = 1.650 to 3.465 V,

VDD = 2.5 to 5.5 V

• Small, QFN (12-pin, 2 x 2 mm, 0.5 mm pitch) package (MSL1,

260 °C per JEDEC J-STD-020)                                   Figure 1. SKY13385-460LF Block Diagram

                                                              Description

                                                              The SKY13385-460LF is a CMOS silicon-on-insulation (SOI),

                                                              single-pole, triple-throw (SP3T) switch. The high linearity

                                                              performance and low insertion loss makes the device an ideal

                                                              choice for WLAN (802.11 b/g) and Bluetooth® applications in the

                                                              2.4 to 2.5 GHz frequency range.

                                                              The SKY13385-460LF SP3T switch is provided in a compact Quad

                                                              Flat No-Lead (QFN) 2 x 2 mm package. A functional block diagram

                                                              is shown in Figure 1. The pin configuration and package are

                                                              shown in Figure 2. Signal pin assignments and functional pin

                                                              descriptions are provided in Table 1.

                                                              Figure 2. SKY13385-460LF Pinout – 12-Pin QFN

                                                                           (Top View)

              Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                    201513B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 18, 2011  1
DATA SHEET • SKY13385-460LF SP3T SWITCH

Table 1. SKY13385-460LF Signal Descriptions

   Pin #             Name                                     Description       Pin #          Name                                                             Description

          1     J1                          RF port 1.                          7         VDD                                                       DC power supply.

          2     GND                         Ground                              8         GND                                                       Ground

          3     J3                          RF port 3.                          9         J2                                                        RF port 2.

          4     V1                          DC control voltage 1. See Table 4.  10        GND                                                       Ground

          5     V2                          DC control voltage 2. See Table 4.  11        RFC                                                       RF common (antenna) port.

          6     V3                          DC control voltage 3. See Table 4.  12        GND                                                       Ground

   Note:     Exposed pad must be grounded.

Table 2. SKY13385-460LF Absolute Maximum Ratings (Note 1)

                     Parameter                                Symbol            Minimum                                                             Maximum                               Units

   Supply voltage (VDD)                                 VDD                         2.5                                                             5.5                                   V

   Control voltage (V1, V2, V3) (Note 2)                VCTL                       1.65                                                             3.50                                  V

   Input power                                          PIN                                                                                         +35                                   dBm

   Storage temperature                                  TSTG                       –40                                                              +125                                  °C

   Operating temperature                                TOP                        –40                                                              +85                                   °C

   Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other

             parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.

   Note 2: Any bias voltage applied to the V1, V2, or V3 pins may damage the device if there is no bias voltage also present on the VDD pin. Maximum control voltage cannot exceed VDD.

CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device

             must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body

             or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. The

             SKY13385-460LF ESD threshold level is 500 VDC using Human Body Model (HBM) testing.

Functional Description                                                          device to 5 μA, typical. To prevent the switch from accidentally

The SKY13385-460LF includes an internal negative voltage                        entering shutdown mode during switching, caution must be taken

generator and decoder that eliminate the need for external DC                   to avoid having all three control signals (V1, V2, and V3) set to

blocking capacitors on the RF ports. No external components are                 logic low for more than 500 ns. When exiting shutdown mode, the

required for proper operation. DC decoupling capacitors may be                  switch has a 25 μs startup time before switching occurs.

added on the VDD and control lines if necessary.

Switching is controlled by three control voltage inputs: V1, V2, and            Electrical and Mechanical Specifications

V3. Depending on the logic voltage level applied to the control                 The absolute maximum ratings of the SKY13385-460LF are

pins, the RFC (RF common) pin is connected to one of three                      provided in Table 2. Electrical specifications are provided in

switched RF outputs (J1, J2, or J3) through a low insertion path,               Table 3.

while the path between the RFC pin and the other RF pins is in a

high isolation state. There is a fourth switching state that enables            The state of the SKY13385-460LF is determined by the logic

J2 and J3 at the same time. The output power measured at J2                     provided in Table 4.

and J3 in this state is 3 dB less than the insertion loss.                      Typical performance characteristics of the SKY13385-460LF are

For proper switching operation, the SKY13385-460LF must be set                  illustrated in Figures 4 through 7.

to a state for a minimum of 10 μs before changing to a different

state. A typical switching diagram is shown in Figure 3.

Shutdown mode is enabled by connecting all control pins to logic

low. This mode reduces the overall current consumption of the

                     Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

2                         May 18, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513B
                                                                            DATA SHEET • SKY13385-460LF                                    SP3T  SWITCH

                                       Figure 3. Typical Switching Diagram

Skyworks Solutions, Inc.  • Phone      [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

201513B • Skyworks        Proprietary  Information • Products and Product Information are Subject to Change Without Notice • May 18, 2011        3
DATA SHEET • SKY13385-460LF SP3T SWITCH

Table 3. SKY13385-460LF Electrical Specifications (1 of 2) (Note 1)

(VDD = 2.5 V to 5.5 V, VCTL = 0 V (Low), VCTL = 1.8 V (High), TOP = +25 °C, PIN =  0  dBm,  Characteristic Impedance  [ZO] = 50                                    Ω,  Unless

Otherwise Noted)

                   Parameter             Symbol  Test Condition                             Min  Typical                                                     Max       Units

   RF Specifications

   Insertion loss                   IL           f = 1 GHz, RFC-J1,

                                                 RFC-J2                                          0.40                                                        0.50      dB

                                                 f = 1 GHz, RFC-J3                               0.45                                                        0.50      dB

   Insertion loss                   IL           f = 2 GHz, RFC-J1,

                                                 RFC-J2                                          0.40                                                        0.50      dB

                                                 f = 2 GHz, RFC-J3                               0.47                                                        0.55      dB

   Insertion loss                   IL           f = 2.4 to 2.5 GHz,

                                                 RFC-J1, RFC-J2                                  0.43                                                        0.55      dB

                                                 f = 2.4 to 2.5 GHz,

                                                 RFC-J3                                          0.52                                                        0.65      dB

   Isolation                        Iso          f = 1 GHz, RFC-J1,                         40   43                                                                    dB

                                                 RFC-J2, RFC-J3

   Isolation                        Iso          f = 2 GHz, RFC-J1,                         34   37                                                                    dB

                                                 RFC-J2, RFC-J3

   Isolation                        Iso          f = 2.4 to 2.5 GHz,                        32   35                                                                    dB

                                                 RFC-J1, RFC-J2, RFC-J3

   Return loss                      |S11|        f = 2.45 GHz                               18   20                                                                    dB

   3rd Order Input Intercept Point  IIP3         f = 2.45 GHz,                              +55  +57                                                                   dBm

                                                 ΔF = 1 MHz,

                                                 PIN = +20 dBm/tone

   Input 0.1 dB compression point   P0.1dB       f = 2.45 GHz

                                                 RFC to J1 and J2                                +32.5                                                                 dBm

                                                 RFC to J3                                       +30.5                                                                 dBm

   2nd harmonic                     2fo          f = 2.45 GHz,                                   +75                                                                   dBc

                                                 PIN = +20 dBm

   3rd harmonic                     3fo          f = 2.45 GHz,                                   +75                                                                   dBc

                                                 PIN = +20 dBm

   Error Vector Magnitude, WLAN     EVM_WLAN     PIN for 2.5% error, WLAN                        +27                                                                   dBm

                                                 2.45 GHz, 802.11g,

                                                 OFDM, 54 Mbps, 64 QAM

   Switching rise time                           10/90% RF                                       180                                                         200       ns

   Switching fall time                           90/10% RF                                       110                                                         130       ns

   Switching on time                             50% VCTL to 10/90% RF                           250                                                         500       ns

   Switching off time                            50% VCTL to 90/10% RF                           190                                                         210       ns

   Logic dwell time (Note 2)                     TOP = –40 °C to +85 °C                     10   12                                                                    μs

   Startup time (Note 3)                         Shutdown state to any RF                        20                                                          25        μs

                                                 switch state

                       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

4                         May 18, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513B
                                                                                                                 DATA SHEET • SKY13385-460LF SP3T SWITCH

Table 3. SKY13385-460LF Electrical Specifications (2 of 2) (Note 1)

(VDD = 2.5 V to 5.5 V, VCTL = 0 V (Low), VCTL = 1.8 V (High), TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless

Otherwise Noted)

                     Parameter                                    Symbol            Test Condition        Min    Typical                                      Max                        Units

DC Specifications

Control voltage (Note 4):

       High                                                 VCTL_HIGH                                     1.650  1.800                                        3.465                      V

       Low                                                  VCTL_LOW                                      0                                                   0.40                       V

Supply voltage                                              VDD                                           2.5                                                 5.5                        V

Supply current                                              IDD                     VDD = 3.5 V                  30                                                                      μA

Control current                                             ICTL                    V1 = V2 = V3 = 1.8 V         2                                                                       μA

Shutdown mode supply current                                IOFF                    VDD = 3.5 V,                 5                                                                       μA

                                                                                    V1 = V2 = V3 = 0 V

Note 1: Performance is guaranteed only under the conditions listed in this Table.

Note 2: Dwell time refers to the amount of time the switch is required to stay in any one state before switching to another state. Refer to the Functional Description section for more

       information.

Note 3: Startup time refers to the amount of time it takes for the switch to be fully operational when coming out of shutdown mode (V1 = V2 = V3 = logic 0).

Note 4: Control voltage must be less than or equal to VDD at all times.

Table  4. SKY13385-460LF Truth Table

                       V1                                                 V2                              V3                                                        State

                       0                                                  0                               0                                                   Shutdown

                       1                                                  0                               0                                                   RFC to J1

                       0                                                  1                               0                                                   RFC to J2

                       0                                                  0                               1                                                   RFC to J3

                       0                                                  1                               1                                                   RFC to J2 and J3

Note:  1 = 1.650 to 3.465 V

       0 = 0 to 0.4 V

       Any state other than described in this Table places  the   switch  into  an  undefined  state.

                       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                           201513B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 18, 2011                                    5
DATA SHEET • SKY13385-460LF SP3T SWITCH

Typical Performance Characteristics

(VDD = 2.5 V to 5.5 V, VCTL = 0 V (Low), VCTL = 1.8 V (High),  TOP  =  +25  °C,  PIN  =  0  dBm,  Characteristic Impedance [ZO] = 50 Ω, Unless

Otherwise Noted)

   Figure 4. Typical Insertion Loss vs Frequency                                                  Figure 5. Typical Isolation vs Frequency

                                                                                                  (RFC to J1 Insertion Loss State)

   Figure 6. Typical Isolation vs Frequency                                                       Figure 7. Typical Isolation vs Frequency

                  (RFC to J2 Insertion Loss State)                                                (RFC to J3 Insertion Loss State)

   Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

6                 May 18, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513B
                                                                                         DATA SHEET • SKY13385-460LF SP3T SWITCH

Evaluation Board Description                                      Package and Handling Information

The SKY13385-460LF Evaluation Board is used to test the           Instructions on the shipping container label regarding exposure to

performance of the SKY13385-460LF SP3T Switch. The board is       moisture after the container seal is broken must be followed.

made from a two-layer construction with ½ oz. copper cladding     Otherwise, problems related to moisture absorption may occur

on top and bottom. The first layer material is 12-mil Rogers      when the part is subjected to high temperature during solder

4003C. The second layer material is 49-mil of FR4 for a total     assembly.

board thickness of about 62 mils. The impedance of all RF traces  THE SKY13385-460LF is rated to Moisture Sensitivity Level 1

is 50 Ω.                                                          (MSL1) at 260 °C. It can be used for lead or lead-free soldering.

An Evaluation Board schematic diagram is provided in Figure 8.    For additional information, refer to the Skyworks Application Note,

An assembly drawing for the Evaluation Board is shown in          Solder Reflow Information, document number 200164.

Figure 9.                                                         Care must be taken when attaching this product, whether it is

                                                                  done manually or in a production solder reflow environment.

Package Dimensions                                                Production quantities of this product are shipped in a standard

                                                                  tape and reel format.

The PCB layout footprint for the SKY13385-460LF is provided in

Figure 10. Typical case markings are shown in Figure 11.

Package dimensions for the 12-pin QFN are shown in Figure 12,

and tape and reel dimensions are provided in Figure 13.

                              Figure 8. SKY13385-460LF Evaluation Board Schematic

           Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

           201513B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 18, 2011  7
DATA  SHEET  •  SKY13385-460LF SP3T SWITCH

                Figure 9. SKY13385-460LF Evaluation Board Assembly Diagram

                                            Figure 10. SKY13385-460LF PCB Layout Footprint

                                            (Top View)

                Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

8               May 18, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513B
                                                            DATA SHEET • SKY13385-460LF                                                   SP3T  SWITCH

                          Figure 11. Typical Case Markings

                          (Top View)

                          Figure 12. SKY13385-460LF 12-Pin QFN Package Dimensions

Skyworks Solutions, Inc.  • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

201513B • Skyworks        Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 18, 2011        9
DATA  SHEET  •  SKY13385-460LF  SP3T  SWITCH

                                      Figure  13.  SKY13385-460LF  Tape  and  Reel  Dimensions

                Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

10              May 18, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513B
                                                                                           DATA SHEET • SKY13385-460LF SP3T SWITCH

Ordering Information

       Model Name                                               Manufacturing Part Number  Evaluation Board Part Number

SKY13385-460LF SP3T Switch                                      SKY13385-460LF             SKY13385-460LF-EVB

Copyright © 2011 Skyworks Solutions, Inc. All Rights Reserved.

Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by

Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the

information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to

update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.

No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or

information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of

Sale.

THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A

PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY

DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS

SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,

LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE

POSSIBILITY OF SUCH DAMAGE.

Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,

death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any

damages resulting from such improper use or sale.

Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of

products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for

applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.

Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands

and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,

are incorporated by reference.

       Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                                201513B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 18, 2011                                     11
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Skyworks:

SKY13385-460LF
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved