DATA SHEET

SKY12235-11: High IIP3 1.4 to                                      2.4  GHz      Voltage-Controlled

Variable Attenuator

Applications

 Automatic power leveling/gain control circuits in cellular base                Control  Control

stations and point-to-point radio IF chains                                      Voltage  Voltage

 General wireless systems including WiMAX, LTE, WCDMA,

VSAT, and military communications

Features

 1.4 to 2.4 GHz broadband operating range

 Maximum attenuation level: 36 dB

 Control voltage range: 0 to 5 V

 High IIP3: +61 dBm

 Low current consumption: <2 mA @ maximum attenuation                                                                                                 201925-001

 Small, MCM (8-pin, 4.9 x 3.2 mm) package

(MSL3, 260 C per JEDEC J-STD-020)

                                                                                 RF       RF

                                                                                 In/Out   Out/In

            Skyworks GreenTM products are compliant with                         Figure 1. SKY12235-11 Block Diagram

            all applicable legislation and are halogen-free.

            For additional information, refer to Skyworks          Description

            Definition of GreenTM, document number

            SQ04–0074.                                             The SKY12235-11 is a voltage-controlled variable attenuator from

                                                                   Skyworks series of high third order input intercept point (IIP3)

                                                                   components. The device has been designed to operate over the

                                                                   1.4 to 2.4 GHz frequency band, but is specifically optimized for

                                                                   use as a wide dynamic range, low distortion attenuator, centered

                                                                   at 1.9 GHz.

                                                                   The SKY12235-11 provides monotonic attenuation performance

                                                                   over its entire control voltage range. This attenuator is comprised

                                                                   of a pair of matched PIN diodes that terminate two ports of its

                                                                   internal 90-degree hybrid coupler. The diodes are biased using an

                                                                   external control voltage signal. The attenuator requires no

                                                                   external components. It operates with a control voltage range of 0

                                                                   to 5 V and a 1.7 mA typical control current at maximum

                                                                   attenuation.

                                                                   A functional block diagram is shown in Figure 1. The pin

                                                                   configuration and package are shown in Figure 2. Signal pin

                                                                   assignments and functional pin descriptions are provided in

                                                                   Table 1.

              Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                      201933G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice June 7, 2016              1
DATA SHEET  •  SKY12235-11: VARIABLE ATTENUATOR

                                                               J2           GND         J1

                                                               8            7           6

                           GND                           1                                         5  GND

                                                               2            3           4

                                                               V_CONTROL    GND         V_CONTROL  201925-002

                                                               Figure 2. SKY12235-11    Pinout

                                                                            (Top View)

Table 1.  SKY12235-11  Signal Descriptions

   Pin      Name           Description                                           Pin        Name                       Description

   1      GND          Ground. Must be connected to PCB ground using             5      GND           Ground. Must be connected to PCB ground using

                       lowest possible inductance path.                                               lowest possible inductance path.

   2      V_CONTROL    Control voltage input (voltage applied is nominally       6      J1            RF input/output

                       equal to the voltage applied to pin 4)

   3      GND          Ground. Must be connected to PCB ground using             7      GND           Ground. Must be connected to PCB ground using

                       lowest possible inductance path.                                               lowest possible inductance path.

   4      V_CONTROL    Control voltage input (voltage applied is nominally       8      J2            RF output/input

                       equal to the voltage applied to pin 2)

Technical Description                                                            also increases. This increased bias current lowers the resistance

The SKY12235-11 is a 50 Ω matched voltage controlled variable                    of the PIN diodes. Maximum attenuation occurs when the

attenuator with monotonic attenuation performance from 1.4 to                    resistance of the PIN diodes equals the characteristic impedance

2.4 GHz over its entire control voltage range. This attenuator                   of the hybrid coupler ports, which they terminate. This occurs at a

requires no external biasing or RF matching components.                          control voltage of approximately 5 VDC.

Monotonic performance means the attenuation increases as the

applied DC voltage increases. This attenuator is comprised of a                  Electrical and Mechanical Specifications

pair of matched PIN diodes that terminate two ports of an internal               The absolute maximum ratings of the SKY12235-11 are provided

90-degree hybrid coupler.                                                        in Table 2. Electrical specifications are provided in Table 3.

The diodes are biased using an external control voltage signal that              Performance characteristics for the SKY12235-11 are illustrated

sets the bias current through a resistive network. The attenuator                in Figures 3 through 8.

operates with a control voltage range of 0 to 5 V and a 1.7 mA

typical control current at maximum attenuation. As the control

voltage increases, the bias current through each of the PIN diodes

               Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

2                    June 7, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201933G
                                                                                                                            DATA SHEET • SKY12235-11: VARIABLE ATTENUATOR

Table 2. SKY12235-11 Absolute Maximum Ratings1

                            Parameter                                                     Symbol                            Minimum       Maximum                                      Units

Control voltage                                                                     VCONTROL                                                       10                                  V

RF input power (CW)                                                                 PIN                                                            4                                   W

Control current                                                                     Icc                                                            50                                  mA

Diode reverse bias voltage                                                                                                                         50                                  V

Storage temperature                                                                 TSTG                                    –40                +85                                     C

Operating temperature                                                               TOP                                     –40                +85                                     C

Electrostatic discharge:                                                            ESD

Charged Device Model (CDM), Class 4                                                                                                            1000                                    V

Human Body Model (HBM), Class 1B                                                                                                               500                                     V

Machine Model (MM), Class A                                                                                                                    100                                     V

1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage  to device with only  one  parameter set at the limit  and  all  other  parameters  set

at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the  device.

ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This

                     device must be protected at all times from ESD when handling or transporting. Static charges may easily produce

                     potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-

                     standard ESD handling precautions should be used at all times.

Table 3. SKY12235-11 Electrical Specifications1

(TOP = +25 C, VCONTROL = 0 to 5 V, PIN = 0 dBm, Characteristic Impedance [ZO]                                  = 50    Ω,  Unless Otherwise Noted)

                Parameter                   Symbol                                  Test Condition                          Min           Typical                     Max                  Units

Attenuation                            Attn         VCONTROL = 5 V, f = 1.9 GHz                                             25            36                                                  dB

Control current                        ICC          VCONTROL = 5 V                                                                        1.7                                              mA

Insertion loss                         IL           VCONTROL = 0 V,

                                                    f = 1.4 to 2.4 GHz                                                                    1.8                         2.5                     dB

Return loss                            RL           VCONTROL = 0 V, f = 1.4 to 2.4 GHz                                           7        18                                                  dB

Third order input intercept point2     IIP3         PIN = +8 dBm each tone, VCONTROL                            = 0 V,

                                                    f1 = 1.900 GHz, f2 = 1.910 GHz                                                        +61                                              dBm

1 Performance is guaranteed only under the conditions listed in this table.

2 Minimum specification is guaranteed by design and is not 100% production tested.

                 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                          201933G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016                                             3
DATA SHEET • SKY12235-11: VARIABLE ATTENUATOR

Typical Performance Characteristics

(TOP = +25 C, VCONTROL = 0 to 5 V, PIN = 0 dBm, Characteristic Impedance                     [ZO] = 50 Ω, J1 = Input Port, J2 = Output Port, Unless Otherwise

Noted)

                               0                                                                                     0

                           –5                                                                                        –5                                                                 +25 °C

                                                                                                                                                                                        +85 °C

                           –10                                                                                                                                                          –40 °C

                                                                                                                     –10

Attenuation (dB)           –15                                                                Attenuation (dB)       –15

                           –20                                                                                       –20

                           –25                                                                                       –25

                           –30                                                                                       –30

                           –35                                                                                       –35

                                                                                       0V

                           –40                                                         1V                            –40

                                                                                       2V

                           –45                                                         3V                            –45

                                                                                       4V

                                                                                       5V

                           –50                                                                                       –50

                                  0         1            2                    3            4                              0           1      2  3                              4        5            6

                                                         Frequency  (GHz)                                                                    Control Voltage                   (V)

                           Figure    3.  Attenuation  vs Frequency  Over Control  Voltage                       Figure 4.       Attenuation  vs Control Voltage                Over  Temperature

                                                                                                                                             (f = 1.90 GHz)

                                                                                                                          0

                           0                                                                  (dB)                   –5

                           –1                                                                 S-Parameter Magnitude

Attenuation Flatness (dB)                                                                                            –10

                           –2

                           –3                                                                                        –15

                           –4                                                                                        –20

                           –5                                                                                                                                                              S11

                                                                                                                     –25                                                                   S21

                                                                                                                                                                                           S22

                           –6

                                                                                                                     –30

                           –7                                                                                                0           1      2                                    3            4

                               0         1            2  3                 4      5        6                                                 Frequency (GHz)

                                                      Control Voltage (V)

                                                                                                                          Figure  6.  S-Parameter Magnitude vs Frequency

                               Figure    5. Attenuation Flatness vs Control   Voltage

                                            (f = 1.4 to 2.4 GHz)

                                         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

4                                           June 7, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201933G
                                                                                                                  DATA SHEET • SKY12235-11: VARIABLE ATTENUATOR

                        0                                                                                 0

                        –5                                                                                –5

Input Return Loss (dB)  –10                                                      Output Return Loss (dB)  –10

                        –15                                                                               –15

                        –20                                                                               –20

                                                                        0V                                                                                                  0V

                                                                        1V                                                                                                  1V

                        –25                                             2V                                –25                                                               2V

                                                                        3V                                                                                                  3V

                                                                        4V                                                                                                  4V

                                                                        5V                                                                                                  5V

                        –30                                                                               –30

                             0  1  2                           3            4                                  0  1       2                                        3            4

                                   Frequency (GHz)                                                                        Frequency (GHz)

Figure 7. Input                 Return Loss vs Frequency Over  Control  Voltage  Figure 8. Output                 Return  Loss vs Frequency Over                   Control  Voltage

Evaluation Board Description                                                     Package and Handling Information

The SKY12235-11 Evaluation Board is used to test the                             Since the device package is sensitive to moisture absorption, it is

performance of the SKY12235-11 variable attenuator. An                           baked and vacuum packed before shipping. Instructions on the

assembly drawing for the Evaluation Board is shown in Figure 9.                  shipping container label regarding exposure to moisture after the

The Evaluation Board layer detail is shown in Figure 10.                         container seal is broken must be followed. Otherwise, problems

The attenuation level of the SKY12235-11 is controlled by                        related to moisture absorption may occur when the part is

applying 0 to 5 V to the V_CONTROL pins.                                         subjected to high temperature during solder assembly.

                                                                                 The SKY12235-11 is rated to Moisture Sensitivity Level 3 (MSL3)

                                                                                 at 260 C. It can be used for lead or lead-free soldering. For

Package Dimensions                                                               additional information, refer to the Skyworks Application Note,

The PCB layout footprint for the SKY12235-11 is shown in                         PCB Design & SMT Assembly/Rework Guidelines for MCM-L

Figure 11. Typical part markings are shown in Figure 12. Package                 Packages, document number 101752.

dimensions are shown in Figure 13, and tape and reel dimensions                  Care must be taken when attaching this product, whether it is

are provided in Figure 14.                                                       done manually or in a production solder reflow environment.

                                                                                 Production quantities of this product are shipped in a standard

                                                                                 tape and reel format.

                                Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

                                201933G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016                    5
DATA SHEET  •  SKY12235-11: VARIABLE ATTENUATOR

                                                                                                  201925-009

               Figure 9. SKY12235-11 Evaluation Board Assembly Diagram

               Cross Section                     Name                                             Thickness (in)  Material

                                                 Top Solder Mask

                                                 L1                                               (0.0028)        Cu foil

                                                 Laminate                                         0.012 ± 0.0006  Rogers RO4003C Core

                                                 L2                                               (0.0014)        Cu foil

                                                 Laminate                                         (Note 1)        FR4 Prepreg

                                                 L3                                               (0.0014)        Cu foil

                                                 Laminate                                         0.010 ± 0.0006  FR4 Core

                                                 L4                                               (0.0028)        Cu foil

                                                 Bottom Solder Mask

               Note 1: Adjust this thickness to meet total thickness goal of 0.062 ± 0.005 inch.                                                  201925-010

               Figure 10. Layer Detail Physical Characteristics

               Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

6              June 7, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201933G
                                                                                         DATA SHEET • SKY12235-11:                             VARIABLE ATTENUATOR

                                    5.2                                                                   5.2

                       Pin 8             6x 0.8

                                                                                                  Pin 8        4x 0.8

                                                         6x 0.75                                                                               4x 0.75

3.5                                                      2x 0.8             3.5

     Pin 1                                                                        Pin 1

                                                                                                                                               0.25

                                                         Package Outline

                       1.37 Typ.                                                                                                               Package Outline

                                         2x 0.93                                                  1.37 Typ.

                       Stencil Aperture                                                           Metallization

                              Top View                                                                   Top View

                                                                  5.3

                                                         Pin 8            6x 0.9

                                                                                         6x 0.85

                                    3.6                                                  2x 0.9

                                         Pin 1

                                                                                         Package Outline

                                                         1.37 Typ.          2x 1.03

                                                         Solder Mask Opening

All  measurements  in  millimeters                                Top View                                                                     201925-011

                                                 Figure  11. SKY12235-11 PCB Layout Footprint

     Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

            201933G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016                       7
DATA  SHEET  •  SKY12235-11:  VARIABLE ATTENUATOR

                                             Pin 1
                                    Indicator
                                                                                                     Skyworks Part Number

                                                                         12235-11                    Lot Code

                                                                       XXXXXX.XX                     YY = Calendar Year

                                                                         YYMM CC                     MM = Month Package Sealed

                                                                                                     CC = County Code

                                                                                         201930-012

                                                     Figure 12. Typical Part Markings

                                                                         (Top View)

                4.9              B

                Pin 1                                                                                                       Pin 8         (2.1)

                Indicator           C                Mold                          MCM                                                              (Ø0.3)

                                                                                   Substrate                                      A                 Solder    Mask   Opening

                                                                                                                                                    (0.8)

                                    3.2                                                                        B                                    0

                                                                                                                                                    Pin 1

                                                                         A

                0.05 A     B  C                      1 ± 0.1                                                          1.37     0          8X     SMT Pad

                                                                                                                                                 0.1       A  BC

                                                     0.025    A                    0.08                               4X

                Top View                                    Side View                                                             Bottom  View

                                                                         Metal Pad Edge                        (0.1)                 0.675 ± 0.075                   R(0.1)

                                                                                                                  0.5 ± 0.075

                                                                                                                                     0.8 ± 0.03

                                                                         R(0.1)                      0.8 ± 0.03

                                                                                                                               Metal Pad Edge                 (0.1)

                                                                                              Detail A                                           Detail B

      Notes:                                                                                         SMT Pad                                     SMT Pad

                                                                                                     Scale 2X                                    Scale 2X

      1.     All measurements are in millimeters.                                             3X This Rotation                                   1X This Rotation

      2.     Dimensions and tolerances according to ASME Y14.5M-1994.                         3X Rotated 180o                                    1X Rotated 180o

      3.     See applicable bonding diagram and device assembly drawing

             for die and component placement.

      4.     Pad definitions per details on drawing.                                                                                                           201925-013

      5.     PCB Type 4L PPG TEV MCM (100).

                                                     Figure 13. SKY12235-11              Package Dimensions

                Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

8               June 7, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201933G
                                                                                                   DATA SHEET • SKY12235-11:                    VARIABLE ATTENUATOR

                                                                                                   ∅1.50 + 0.1/–0.0

0.30 ± 0.05                         Pin 1   2.00 ± 0.05                               4.00 ± 0.10

                                                                                                                                                1.75 ± 0.10

                                         B                                                                                                      5.50 ± 0.05

                                         A                       A                                                                                           12.00 ± 0.30

             5.20 ± 0.10

                                         B

1.30 ± 0.10                                                                           8.00 ± 0.10          ∅1.50 Min

        B                                                           3.50 ± 0.10

Notes:                                                              A

1. Carrier tape: black conductive polycarbonate or polystyrene.

2. Cover tape material: transparent conductive PSA.

3. Cover tape size: 9.30 mm width.                                                                                                                           201925-014

4. Sprocket hole (10) pitch cumulative tolerance: ±0.20 mm.

5. All measurements are in millimeters.

                                                     Figure 14.     SKY12235-11 Tape  and Reel Dimensions

             Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

             201933G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016                             9
DATA SHEET • SKY12235-11: VARIABLE ATTENUATOR

Ordering Information

          Model Name                                                                    Manufacturing Part Number  Evaluation Board Part Number

    SKY12235-11: Voltage-Controlled Variable Attenuator                    SKY12235-11                             SKY12235-11-EVB

Copyright © 2012-2014, 2016 Skyworks Solutions, Inc. All Rights Reserved.

Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by

Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the

information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to

update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.

No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or

information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions

of Sale.

THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A

PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY

DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS

SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,

LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE

POSSIBILITY OF SUCH DAMAGE.

Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,

death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any

damages resulting from such improper use or sale.

Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of

products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for

applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.

Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands

and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,

are incorporated by reference.

          Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com

10                              June 7, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201933G
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Skyworks:

SKY12235-11  SKY12235-11-EVB

小广播

SKY12235-11器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved