datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索

PXD2048D12

器件型号:PXD2048D12
器件类别:电源    DC DC Converters   
文件大小:632.83KB,共3页
厂商名称:TDK
厂商官网:http://www.tdk.com/
标准:  
下载文档

器件描述

DC-DC convtr +/-12v 20w +/-.833a

参数

Datasheets:
PXD Series Instr Manual:
PXD Series:
Product Photos:
PXD2048D12:
Other Related Documents:
PXD30,20 Series /P Marking:
Other Drawings:
PXD Series Side:
PXD Series Bottom:
Standard Package : 1
Category: Power Supplies - Board Mount
Family: DC DC Converters
Series: PXD
Packaging : -
Type: Isolated Module
Number of Outputs: 2
Voltage - Input (Min): 36V
Voltage - Input (Max): 75V
Voltage - Output 1: 12V
Voltage - Output 2: -12V
Voltage - Output 3: -
Current - Output (Max): 833mA, 833mA
Power (Watts) - Manufacture Series: 20W
Voltage - Isolation: 1.6kV (1600V)
Features: Remote On/Off, OCP, OVP, SCP
Mounting Type: Through Hole
Package / Case: 6-DIP Module
Size / Dimension: 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 8.6mm)
Operating Temperature: -40°C ~ 100°C
Efficiency: 88%
Power (Watts) - Max: 20W
Dynamic Catalog: PXD Series
Other Names: 285-1519PXD20-48D12PXD2048D12/P

PXD2048D12器件文档内容

                              Installation Data Sheet

                                                             PXD Series (dual output) DC-DC Converters

The PXD is a DC-DC converter which provides a fully isolated and regulated output at power levels up to 20 watts. It accepts a wide
range DC input. The converter may be operated with or without the input and output pins grounded.

Table of Contents

      General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
      Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
      Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
      Soldering and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
      Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
      Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
      EMI Filter (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
      Minimum Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
      Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
      Remote On-Off Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
      Thermal Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

General Safety Instructions                                           Soldering and Cleaning

These products are designed to be PCB mounted and for use                   Flow soldering : 26010C less than 15 seconds
within other equipment or enclosures. For safe installation and             Soldering iron : 37010C less than 5 seconds
operation, carefully follow the instructions below:

1. Do not install, test, or operate the products near water or        Note: The pins of this module are coated with Tin. To assure the
    spill liquid on them.                                             solder-ability, modules should be kept in their original shipping
                                                                      containers to provide adequate protection. Also, the storage
2. Do not operate these products unless they are securely             environment should be controlled to prevent oxidation of the pins.
    fastened.
                                                                      Following wave solder, the converters should be given an
3. These products must be installed in a restricted access            opportunity to cool to within 10C of the cleaning solution
    location accessible to authorized personnel only.                 temperature. Cleaning while at a higher temperature may
                                                                      increase the risk of vacuum absorption of the solution into the
4. These products must be professionally installed in                 converter between the pins and potting material during cooling.
    accordance with the prevailing electrical wiring regulations
    and safety standards.                                             It is recommended that during the wash process, the date code
                                                                      screening is protected to avoid erasure.
5. The output power taken from the unit must not exceed the
    ratings stated in the catalog datasheet.

6. Ensure adequate ventilation is provided to allow air to
    circulate.

7. This product has functional insulation between input and
    output and therefore the DC source to this product must
    be reinforced or double insulated to the AC input in
    accordance with IEC/EN 60950-1 to achieve SELV output.

Fusing

External ceramic sand-filled fuse, 250V, F5A, HBC.

Installation Method

The unit can be mounted in any direction. Position single or
multiple units with proper spacing to allow for adequate air
ventilation. The case temperature of each unit should not exceed
the temperature range as noted in the data sheet.

Avoid placing PCB traces for the DC input and DC output directly
under the unit to limit the possibility of unwanted conducted noise.

3055 Del Sol Blvd San Diego, CA 92154 1-800-LAMBDA-4
                                                              Installation Data Sheet

Block Diagram

                                                Appropriate hook-up location for             DVM
                                                test equipment to monitor output.

                                    L1                                                                              0.1uf

          DC +           Fuse                       +Vin PXD        +Vo                 1uf     Coax cable                        Oscilloscope
          Source              C1                                                                                        50
                                    Optional    C2
                    -
                                    EMI

                                    Filter          -Vin                           -Vo

                                                                                             Load

                                                    Remote On / Off Com

                                                                                             Load

          System Ground

EMI Filter (Optional)                                               Outline Drawing

Input filter components (C1, C2, L1) are used to help meet special

conducted emissions requirements for the PXD product. These                                  1.00(25.4)

components should be mounted as close as possible to the DC-                                         0.50
                                                                                                     (12.7)
DC converter; and all leads should be minimized to decrease
                                                                                                   0.40
radiated noise.                                                                         0.40       (10.2)           0.40
                                                                                        (10.2)                      (10.2)
                         C1                 L1            C2

   PXD10              22F 100v     3.3H           22F, 100V

                      Electrolytic                  Electrolytic

   PXD15, PXD20 1F, MLC            5.5H           39F 100V

                                                    Electrolytic

Minimum Load                                                                            34 5

A 10% (of full load) minimum load is required on output to meet                         Bottom
the performance specifications. These models do not maintain
regulation and operate properly under a no-load condition.                              View

                                                                                              12 6

Pin Assignments

Pin       Connection

1         + Input

2         - Input

3         + Output                                                                                       0.10(2.5)            0.22(5.6)
                                                                                                         0.20(5.1)
4         Common

5         - Output

6         Remote On / Off                                                                1. All dimensions in Inches (mm)
                                                                                         2. Pin Pitch tolerance 0.014(0.35)

                                                                    Pin Diameter: 1mm (0.04")

                                    3055 Del Sol Blvd San Diego, CA 92154 1-800-LAMBDA-4
                                                                    Installation Data Sheet

Remote On-Off Control                                                 Thermal Consideration

Negative Logic                                                        The power module operates in a
To turn the module on and off, the user must supply a switch (or
equivalent circuit below) to control the voltage between the on/off   variety of thermal environments;             Top View
terminal Von/off and the Vi(-) input terminal. With an open circuit,  however, sufficient cooling
the module is normally off. To turn the module on, the voltage on
the Von/off pin needs to be 0V-1.2V. The maximum current Ion/off      should be provided to help         (+)Vout                  (+) Vin
should be limited to less than 200A.                                 ensure reliable operation of the  Common                    (-) Vin
                                                                      unit. Heat is removed by           (-)Vout                   CTRL
Positive Logic                                                        conduction, convention, and
To turn the module on and off, the user must supply a switch (or
equivalent circuit below) to control the voltage between the on/off   radiation to the surrounding
terminal Von/off and the Vi(-) input terminal. With an open circuit
the module is normally on. To turn the module off, the voltage on     environment. Proper cooling can
the Von/off pin needs to be 0V-1.2V. The maximum current Ion/off
should be limited to less than 100A.                                 be verified by measuring the

Below are five possible circuits for driving the ON/OFF Pin:          case temperature. The case
                                                                      temperature (Tc) should be

                                                                      measured at the position indicated in figure to the right.

                                                                      When operating the module, adequate cooling must be provided
                                                                      to maintain the case temperature at or below 100C. Maintaining
                                                                      a lower temperature will yield higher reliability of the device.
                                                                      Optimum cooling is obtained with forced convection.

                On/Off Control           On/Off Control               Flow Rate                          
                                                                      Convection*                       16.20C/W
                               Vin (-)                     Vin (-)    100LFM                            12.98
Opto Isolated Remote On/Off                                           200LFM                            10.47
                                               Positive Logic         300LFM
                                         (Permanently Disabled)       400LFM                              8.47
                                                                      500LFM                              6.61
            5V                           On/Off Control               Heatsink**                          6.12
                                                                                                        10.00
TTL/
CMOS                     On/Off Control                               * Mounted vertically
                                                                      ** Optional heatsink 7G0020A (includes adhesive pad)

                Vin (-)                                    Vin (-)

                                               Positive Logic
                                         (Permanently Enabled)

                                         On/Off Control

                                                          Vin (-)
                Open Collector Remote On/Off

                                                                                                                   Rev. A1: Sept 2005

                                        3055 Del Sol Blvd San Diego, CA 92154 1-800-LAMBDA-4
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

PXD2048D12器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved