电子工程世界电子工程世界电子工程世界

产品描述

搜索

MLX90109EDC-AAA-000-TU

器件型号:MLX90109EDC-AAA-000-TU
器件类别:热门应用    无线/射频/通信   
厂商名称:Melexis
厂商官网:https://www.melexis.com/zh
下载文档

器件描述

RFID Transponders 125 kHz RFID Reader IC

参数
产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Melexis
产品种类:
Product Category:
RFID Transponders
RoHS:YES
封装:
Packaging:
Tube
系列:
Series:
MLX90109
商标:
Brand:
Melexis
工厂包装数量:
Factory Pack Quantity:
80

MLX90109EDC-AAA-000-TU器件文档内容

MLX90109

125kHz RFID Transceiver

Features and Benefits

        Integrated RFID transceiver

         Adressing 100kHz to 150kHz frequency range transponder.

         Biphase and Manchester ASK.

         ON/OFF keying modulation.

        Low Power and high performances

         Unique Parallel Antenna concept for maximum power efficiency.

         Power down mode available.

         Baud rate selectable “on-chip” filtering for maximum sensitivity.

         No zero modulation problems.

        Low cost and compact design

         SO8 package and high level of integration for compact reader design.

         No external quartz reference required, only 2 resistors plus antenna.

         On chip decoding for fast system design and ease of use.

         Open drain data and clock outputs for 2-wire serial communication.

Applications Examples

        Car Immobilizers

        Portable readers

        Access control

        House held appliances

Ordering Code

Product Code       Temperature Code         Package Code           Option Code  Packing Form Code

MLX90109                   E                       DC              AAA-000      RE

MLX90109                   E                       DC              AAA-000      TU

MLX90109                   C                       DC              AAA-000      RE

MLX90109                   C                       DC              AAA-000      TU

Legend:

Temperature Code:        E for Temperature Range -40°C to 85°C

                         C for Temperature Range 0°C to 70°C

Package Code:            DC for SOIC150Mil

Packing Form:            RE for Reel, TU for Tube

Ordering example:        MLX90109EDC-AAA-000-RE

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

1.  Functional diagram                                   2. Description

    VDD                                                  The  MLX90109    is  a   single  chip  RFID  transceiver   for   the

                                                         125kHz    frequency      range.  It    has  been      conceived  for

         VDD                                             minimum system cost and minimum power consumption,

               MLX90109   MODU          RC modulation    offering all required flexibility for a state of the art AM

                                                network  transceiver base station. An external coil (L), and capacitor

         COIL                                            (C)  are  connected      as   a  parallel   resonant  circuit,   that

                                                         determines  the      carrier     frequency   and      the  oscillator

                (1)  (2)                                 frequency of the reader.         This eliminates zero modulation

                                                         effects by perfect antenna tuning, and avoids the need for

                                                         an external oscillator.

                          microcontroller                The reader IC can easily be switched to power down by

                                                         setting the antenna amplitude to zero.

               (1): MODE/SPEED config settings           The MLX90109 can be configured to decode the

               (2): DATA/CLOCK outputs                   transponder signal on-chip. In this case the decoded signal

                                                         is available through a 2-wire interface with clock and data.

                                                         For minimum interface wiring, the non-decoded

                                                         transponder signal can also be made available on a single

                                                         wire interface.

                                                                                                               Page 2 of 17

    REVISION 011 - JUNE 19, 2017

    3901090109
MLX90109

125kHz RFID Transceiver

Contents

Features and Benefits................................................................................................................................ 1

Applications Examples............................................................................................................................... 1

Ordering Code ........................................................................................................................................... 1

1. Functional diagram................................................................................................................................ 2

2. Description ............................................................................................................................................ 2

3. Maximum ratings................................................................................................................................... 5

4. Pad definitions and descriptions............................................................................................................ 5

5. MLX90109 Electrical Specifications........................................................................................................ 6

6. Block Diagram........................................................................................................................................ 7

7. General Description............................................................................................................................... 7

7.1. Loop Gain Oscillator............................................................................................................................7

7.2. Peak Detector......................................................................................................................................7

7.3. Band-Pass Filter...................................................................................................................................7

7.4. Digital demodulator ............................................................................................................................ 8

7.5. Antenna voltage definition.................................................................................................................8

7.6. Power Down mode ............................................................................................................................. 8

7.7. Write operation .................................................................................................................................. 8

8. System design parameters..................................................................................................................... 9

8.1. Auto start-up condition ......................................................................................................................9

8.2. Antenna current..................................................................................................................................9

8.3. Antenna Impedance .........................................................................................................................10

9. Typical configuration: READ ONLY ....................................................................................................... 11

9.1. Application diagram..........................................................................................................................11

9.2. Absolute minimum schematic..........................................................................................................11

9.3. Power consumption..........................................................................................................................11

9.4. Noise cancellation.............................................................................................................................12

9.5. Integrated decoding .........................................................................................................................12

9.6. Close coupling ...................................................................................................................................12

10. Typical configuration: READ/WRITE ON/OFF keying (FDX-B100)........................................................ 13

10.1. Application diagram........................................................................................................................13

11. Standard information regarding manufacturability of Melexis products with different soldering

processes............................................................................................................................................ 14

12. ESD Precautions................................................................................................................................. 14

                                                                                                   Page 3 of 17

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

13. FAQ ................................................................................................................................................... 15

13.1. Is it possible to make proportional modulation (depth less than 100%) with the MLX90109? .15

13.2. How should I read data information from a transponder up to 15cm? ......................................15

13.3. Is it possible to increase the output power of the MLX90109 transceiver? ...............................15

13.4. Are there any specific coils available for the MLX90109 transceiver? ........................................15

13.5. What are the recommended pull-up values on DATA and CLOCK pins?.....................................15

14. Package Information.......................................................................................................................... 16

14.1. Plastic SO8.......................................................................................................................................16

15. Contact.............................................................................................................................................. 17

16. Disclaimer.......................................................................................................................................... 17

                              Page 4 of 17

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

3. Maximum ratings

                                                          Symbol   Condition   Min   Max      Unit

Supply voltage (VDD with respect to VSS)                  VDD              DC  -0.3  6        Volts

Input voltage on any pin (except COIL,    DATA       and  VIN                  -0.3  VDD+0.3  Volts

CLOCK)

Input voltage on COIL, DATA and CLOCK                     Vclamp               -0.3  15       Volts

Maximum junction temperature                              TJ                         150      ºC

     Table 1: Absolute maximum ratings

Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated conditions

for extended periods may affect device reliability.

4. Pad definitions and descriptions

Pad Name            Function

COIL                Oscillator output

VSS                 Ground

SPEED               Data rate selection : 2kbaud     or 4kbaud

MODU                Input for amplitude setting

MODE                Decoding        mode  selection  :    Biphase      or

                    Manchester

CLOCK               Clock output of decoder

DATA                Data output of decoder

VDD                 Power Supply

     Table 2:  Pin  description MLX90109

                                                          Plastic SO8

                                                                                                     Page 5 of 17

      REVISION 011 - JUNE 19, 2017

      3901090109
MLX90109

125kHz RFID Transceiver

5. MLX90109 Electrical Specifications

DC Operating Parameters TA = -40oC to 85oC, Fres = 125kHz, VDD = 3.1 to 5.5V

Antenna parameters: Lant = 73.6uH, Qant =17.3, Zant=1k

Parameter.                                  Symbol         Test Conditions                        Min          Typ            Max     Units

Supply Voltage                              VDD                                                   3.1                         5.5     V

Resonance Frequency                         Fres           (Depends on the resonance              100               125       150     kHz

                                                           frequency of the antenna)

Frequency drift with temperature             Fres   T)   Fres = 125 kHz                              -1                        +1   %

Sensitivity (note 1)                        Vsens          (Depends on the application)                             10           30   mVpp

Amplitude Offset (note 2)                   Vos                                                        0          0.15        0.35    V

Power down voltage                          Vpd            VDD=5V                                 4.0                         4.9     V

(on MODU pin)                                              VDD=3.1V                               2.2                         3.0

Power up voltage                            Vpu            VDD=5V                                 3.2                         4.3     V

(on MODU pin)                                              VDD=3.1V                               1.3                         2.4

Power down Current                          IDD,pn         VMODU = VDD                                 0                      1.5     μA

Supply Current (excluding antenna           IDD            VDD=5V, VMODU = 0.8V                                     1.8       3.0     mA

supply current) (note 3)

Antenna supply current (note 4)             IDD,ant        (Depends on the application)                             2.8               mA

Leakage current on pins COIL,               Ileak          (Power down)                                                       1.0     μA

MODE, SPEED, MODE, DATA

Output voltage DATA and CLOCK pin           Vol            Pull-up resistance Rpu > 2k                                       0.4     V

Table 3: Electrical specifications

Note 1:     The sensitivity is defined as the minimum amplitude                                                   Supply voltage VDD

of  the  2kHz-        modulation,  generated  by     the  transponder,

demodulated     and       decoded  by  the  reader.  This  parameter

depends on the application:                                                                       IDDant       A         IDD  A

           the value of VDD

           the antenna                                                                           Lant

           the code sent to the reader

Note 2: The antenna amplitude voltage is:                                                         Cant

Vant = VDD – VMODU + Vos                                                                 COIL                  VDD

                                                                                               1            8

Note 3:     The supply current of the device depends on            the                   VSS   2  MLX90109  7

antenna drive current IDD,ant:                                                                 3            6

Typically:  IDD  1.3 mA + IDD,ant / 6.3

                                                                                 MODU          4            5

Note 4: The antenna supply current (called IDD,ant) is the

equivalent DC supply current driven by the chip through            the

antenna.

                                                                                                                                      Page   6  of  17

    REVISION 011 - JUNE 19, 2017

    3901090109
MLX90109

125kHz RFID Transceiver

6.  Block  Diagram

           VDD

                  VDD                                                                   MLX90109

                                       Peak                    Band-pass                Comparator

                                       Detector                Filter

                  COIL                 clock

                                       Loop Gain               Digital                              DATA

                                       Oscillator              Decoder                              CLOCK

                  GND

                                       MODU                    SPEED              MODE

7. General Description

7.1. Loop Gain Oscillator

The oscillator frequency is locked on the antenna resonance frequency. The clock is derived from the oscillator. In this way,

its characteristics are locked to the transmission frequency.  As the antenna is used to determine the carrier frequency, the

antenna is always perfectly tuned to resonance. Consequently the MLX90109 is not sensitive to zero modulation (the so-

called “zero modulation” is the phenomena whereby the tag does modulate properly, but no amplitude modulation can be

observed at the reader coil).

7.2. Peak Detector

The peak detector of the transceiver detects the AM signal generated by the tag.  This signal is filtered and amplified by an

on-chip switched capacitor filter before feeding the digital decoder. The same signal is fed back to close the loop of the

antenna voltage.

7.3. Band-Pass Filter

By setting the SPEED pin to VDD or to GND, the filtering characteristics are optimized for either 2 or 4 kbaud. The MLX90109

makes an internal first-order filtering of the envelope that changes according to the setting of the SPEED pin, to fit the

Biphase and Manchester data spectrum:

2kbaud (speed pin to VDD) :       400Hz to 3.6kHz

4kbaud (speed pin to VSS) :       800Hz to 7.2kHz

                                                                                                    Page 7 of 17

    REVISION 011 - JUNE 19, 2017

    3901090109
MLX90109

125kHz RFID Transceiver

7.4. Digital demodulator

The MODE pin allows to define whether the MLX90109 will issue directly the filtered data stream on the DATA pin (MODE

floating), or decode it in Manchester (MODE = VDD) or Biphase (MODE = VSS).         In these two decoding modes, the MLX90109

issues the tag data on the DATA pin at the rising edge of the clock, which is issued on the CLOCK pin. Both CLOCK and DATA

are open drain outputs and require external pull-up resistors.

                         VSS                 FLOAT (*)          VDD

        SPEED            4kBaud                    -            2kBaud

        MODE             Biphase             No decoding        Manchester

(*) Internally strapped to VDD/2

7.5. Antenna voltage definition

The MLX90109 is a reader IC working in a frequency range of 100 to 150kHz, and designed for use with a parallel L-C

antenna. This concept requires significantly less current than traditional serial antennas, for building up the same magnetic

field strength.

The voltage on the MODU pin (VMODU) controls the amplitude of the antenna voltage Vant, as follows:

(1)     Vant  VDD VMODU  VOS

with VOS, the offset relative to the VMODU level.

Note: In order to use the internal driver FET as an ideal current source, the voltage on the coil pin should remain higher than

its saturation voltage (typically 0.5V) for a driver current (Idriver) up to 14mA.  As this offset can be as much as 300mV, VMODU

should be higher than 0.8V for a correct operation.

7.6. Power Down mode

By setting VMODU higher than Vpd (preferably to VDD) the MLX90109 goes in power down. The antenna voltage will fade to 0V.

The MLX90109 powers up by pulling VMODU below Vpu.

7.7. Write operation

A sequence of power up / power down periods sets the antenna voltage ON and OFF. This feature allows to simply make an

ON/OFF-keying modulated signal to the transponder.

Typically, VMODU is toggled between VDD and 0.8V. Antenna fade-out is related to the quality factor of the antenna (Qant) and

its start-up takes about 3 carrier periods.

Refer to the section “Typical operating configurations” further in this document for more detailed information and practical

hints.

                                                                                                     Page 8 of 17

     REVISION 011 - JUNE 19, 2017

     3901090109
MLX90109

125kHz RFID Transceiver

8. System design parameters

The  antenna  internal   driver    is  switched    on  as  soon        as  the  antenna  voltage  V(COIL)  drops  below   V DD  (see  graphical

representation below). The MLX90109 will inject a current Idriver into the antenna to make its amplitude follow the voltage

on the MODU pin.

In order to make the antenna start swinging on the resonance frequency, the chip needs to provide a positive feedback loop.

This loop requires a minimal voltage swing at the COIL pin in order to be operational (typically 100mVpp). Below this value,

the MLX90109 may not be able to retrieve its clock.

     V(COIL)

     VDD

VMODU

     VSS

Idriver

                         on

Graph:

Antenna voltage and Driver current during normal operation. VMODU=0.8V for VDD=5V. The dashed curve shows the antenna voltage when

the reader has been powered down. The internal driver current is a square wave with a 45% duty cycle.

8.1. Auto start-up condition

Pulling VMODU, at power on, from 5V to less than Vpu will set the internal driver FET on.         Provided the voltage drop on the coil

pin is large enough (as explained above), the feedback loop is closed and the oscillation will increase in amplitude.

To obtain the required positive feedback to start-up the oscillation successfully, the antenna impedance Zant should be larger

than 1k. This is so called “auto start-up condition”.

8.2. Antenna current

The MLX90109 is specified to drive a maximum 14mA antenna drive current (Idriver).

The AC equivalent supply current (IDDant) can be calculated as:

(2)       I DDant    2   sin(   )  I driver    0.63  I driver      with  the duty cycle which is typically 45%.

                      

The current that the MLX90109 can inject at each oscillation onto the total antenna current is therefore limited to 9mA.

The actual antenna current that generates the magnetic field can be calculated as:

(3)       I ant  Qant  I DDant

A typical coil quality factor (Qant) value is 23, resulting in antenna currents of about 100mA

This current resonance of the parallel antenna allows to build very low power reader base stations, contrary to serial

antenna based versions. Readers using a serial antenna can leverage their voltage resonance to drive bigger antenna’s for

long distance reading up to 1m, whereas the MLX90109 is designed to drive antennas to obtain a reading distance of 1cm up

to 15cm (6”) (depending on efficiency and dimensions).

                                                                                                                                Page 9 of 17

     REVISION 011 - JUNE 19, 2017

     3901090109
MLX90109

125kHz RFID Transceiver

8.3. Antenna Impedance

The antenna impedance is an important system design parameter for the MLX90109.

(4)       Zant      Vant

                     I DDant

The antenna impedance can also be calculated as:

(5)       Zant  Qant res  Lant            with    ωres = 2*Fres

From (4) and (5):

Qant res  Lant         Vant         =>    Qant   I DDant       Vant

                           I DDant                                   res  Lant

Finally in comparison with the formula (2):

(6)       I ant        Vant

                     res  Lant

From the formula above, it is clear that Qant has no influence on Iant. Increasing Qant is equivalent to reduce the antenna

supply current IDDant, hence it reduces the overall current consumption.

Using the previous formula (6), it is possible to define the proportionality between the total number of ampere-turns,

generating the magnetic field and the inductance of the antenna (With Nant the number of turns of the antenna coil) :

Nant    Iant    Nant       Vant      with  Lant ~  N           2

                           res  Lant                   an    t

(7)       Nant  Iant ~             1

                                  Lant

Hence, to generate a strong field, it is better to choose a low antenna inductance. Limitation to this is given by the minimal

antenna impedance (Zant > 1k) and the Q that one can achieve for such an antenna:

(8)       Lmin            Z min

                     Qant  res

Remarks:

Note for equation (4): Mind that in reality the strong coupling with the tag may drastically reduce the antenna impedance.

Note for equation (5): Mind that the quality factor of the antenna (Qant) result in the quality factor of the coil and the quality

factor of the capacitance as:

(9)       Qant  Qcoil // Qcapacitance

So, a capacitance with a low quality factor may also reduce the antenna impedance.

                                                                                                                             Page 10 of 17

     REVISION 011 - JUNE 19, 2017

     3901090109
MLX90109

125kHz RFID Transceiver

9. Typical configuration: READ                   ONLY

9.1. Application diagram

The MLX90109 is a highly integrated reader IC.   In the application schematic below, only two                            resistors to set VMODU are

required, next to the antenna inductance and     tune capacitor. Capacitors C1 and CD can be                             added for a better noise

cancellation.

                                                                                   VDD                  Microcontroller

                              VDD

                                                                                    CD=100nF

                                                        L, C

                                                        1                 8                       100k  100k

                         C1        100k                 2                 7  DATA

                                                        3  MLX  90109     6  CLOCK

                                                        4                 5  MODE

                                                                             SPEED

                                   19k

9.2. Absolute minimum schematic

The interface with the microcontroller can be realized  with  only           one connection.  In  this case, the         mode  pin  is  left  floating

and the integrated decoding is not used.

                                                                                   VDD                  Microcontroller

                              VDD

                                                                                    CD=100nF

                                                        L, C

                                                        1                 8                       100k

                         C1        100k                 2                 7  DATA

                                          SPEED         3  MLX     90109  6  CLOCK

                                                        4                 5  MODE

                                   19k

9.3. Power consumption

If the power consumption is not critical and the reader does not have to be put in power down, the MODU voltage can be

strapped to the required level (between 0.8V and Vpd). However, the power consumption can be reduced by controlling the

voltage on VMODU pin (e.g. with an IO port of a microcontroller).

                                                                                                                                              Page 11 of 17

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

9.4. Noise cancellation

The read performance of a reader is linked with its robustness versus noise. The IC design has been optimized to get a high

signal-to-noise ratio (SNR).    The resonant antenna is a natural band-pass filter, which becomes more effective as its quality

factor Qr increases.

Noise rejection could also be improved by a careful PCB design, and by adding decoupling capacitor(s) on the supply lines.

The most sensitive pins to noise injection are MODU and VDD. Since they directly determine Vant, the noise could be

considered as an amplitude modulation (AM) data from a transponder.

If the noise on both pins were identical, it would cancel out, giving a very noise-insensitive reader. Adding a capacitor C1

between MODU and VDD, together with R1 and R2 yields a high pass filter with a cut-off frequency at:

Fcu t  o ff         1

                 2   (R1 // R2 )  C1

Typically, such a filter should short all noise in the data spectrum, but for many cases, it might be beneficial to set it to less

than the net frequencies (50Hz, 60Hz). For example: R1=100k, R2=19k (to set VMODU), and C1=220nF gives a cut off

frequency of 45Hz.

9.5. Integrated decoding

The  MLX90109         provides  the       option  to  have  a  decoded  output.  This  significantly  reduces  the  complexity  of  the

microcontroller software.

The data is available when the output clock signal is high. The clock signal has a 50% duty cycle when the data is valid. When

the noise level is stronger than the signal level, for instance when no tag is present in the reader field, the duty cycle will be

random. The microcontroller can use this feature to detect the presence of a tag: in that case, it must allow some asymmetry

on the clock. As the sampling error may be 4μs, it should allow a margin of 8 or 12μs.

Remark that when the MLX90109 picks up a Manchester-encoded signal whereas the MODE pin is strapped to VSS (= Biphase

decoding), the clock will also be asymmetric.

9.6. Close coupling

For very short operating distances, a strong coupling with a tag may drastically reduce the antenna impedance Zant. If the

current (Idriver) driven by the antenna internal driver FET goes higher than 14mA, the antenna voltage Vant may be reduced

and the MLX90109 may be unable to read the transponder.

Coupling effect is application-dependent and must be evaluated case by case.

                                                                                                                    Page 12 of 17

     REVISION 011 - JUNE 19, 2017

     3901090109
MLX90109

125kHz RFID Transceiver

10. Typical configuration: READ/WRITE ON/OFF keying (FDX-B100)

10.1. Application diagram

The basic principle is to switch the voltage on MODU between 0V and VDD. The antenna will reach its maximum amplitude in

less than 3 periods when MODU is stepped down from VDD to VSS.   Setting the chip in power-down (set VMODU up to VDD) will

let the antenna fade-out with a time constant, depending on the antenna’s quality factor Qant.           For fast protocols, an

additional drain resistor on MODU controlled by the microcontroller could be used to decrease the fall time (refer to the

application note MLX90109 “100% modulation (ON/OFF Keying)”.

                                                                 FAST_MOD

                                                                 VDD                    Microcontroller

                             VDD

                                                                        CD=100nF

                                        L, C

                                        1                     8                   100k  100k

                         C1       100k  2                     7  DATA

                                        3  MLX  90109         6  CLOCK

                                        4                     5  MODE

                                                                 SPEED

                                  19k

                                                                 MODU

Note : Care should be taken to the capacitor C1 which may reduce the fall time.

                                                                                                         Page 13 of 17

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

11. Standard information regarding manufacturability of Melexis products

with different soldering processes

Our  products  are   classified  and  qualified  regarding    soldering  technology,  solderability  and  moisture  sensitivity  level

according to following test methods:

Reflow Soldering SMD’s (Surface Mount Devices)

    IPC/JEDEC J-STD-020

     Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices

     (classification reflow profiles according to table 5-2)

    EIA/JEDEC JESD22-A113

     Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing

     (reflow profiles according to table 2)

Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)

    EN60749-20

     Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat

    EIA/JEDEC JESD22-B106 and EN60749-15

     Resistance to soldering temperature for through-hole mounted devices

Iron Soldering THD’s (Through Hole Devices)

    EN60749-15

     Resistance to soldering temperature for through-hole mounted devices

Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)

    EIA/JEDEC JESD22-B102 and EN60749-21

     Solderability

For  all  soldering  technologies  deviating     from  above  mentioned  standard     conditions     (regarding  peak  temperature,

temperature gradient, temperature profile etc) additional classification and qualification tests have to be agreed upon with

Melexis.

The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of adhesive

strength between device and board.

Melexis is contributing to global environmental conservation by promoting lead free solutions. For more information on

qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the use of certain Hazardous

Substances) please visit the quality page on our website:

http://www.melexis.com/quality.aspx

12. ESD Precautions

Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).

Always observe Electro Static Discharge control procedures whenever handling semiconductor products.

                                                                                                                       Page 14 of 17

     REVISION 011 - JUNE 19, 2017

     3901090109
MLX90109

125kHz RFID Transceiver

13. FAQ

13.1. Is it possible to make proportional modulation (depth less than 100%) with the

MLX90109?

The amplitude of the MLX90109 antenna can be adjusted on the fly by changing the MODU pin level between VMODU = 0.8V

and Vpd. However, the MLX90109 cannot change instantaneously the voltage on its antenna according to a voltage step on

MODU pin, and a transient waveform will appear on the voltage antenna. This particular waveform may disturb the

transponder and in the worst case (modulation depth more than 20%) the MLX90109 may stop its oscillation.

Using the MLX90109 with proportional modulation (modulation depth less than 100%) is not recommended and supported

by Melexis and must be evaluated case by case.

13.2. How should I read data information from a transponder up to 15cm?

The reading distance depends on the complete system composed by the reader and the transponder. A reading distance

with the MLX90109 transceiver up to 15cm has been demonstrated with a specific reader’s antenna (diameter = 130mm,

Inductance = 44μH, Quality factor Qant = 87.2@125kHz) and a transponder with a credit card size antenna (80 x 50mm).

13.3. Is it possible to increase the output power of the MLX90109 transceiver?

The current flowing through the antenna (IANT) can be maximized by a careful design, respecting the design specification of

the MLX90109 (Auto start-up impedance, the maximum driver current IDRIVER).

The voltage on the antenna cannot be increased as it is limited by the power supply VDD (Vant ≤ VDD-VMODU+Vos). Moreover, as

the MLX90109 uses the same connection (COIL ) for the transmission and the reception, it is not possible to use an external

power transistor supplied with a higher voltage than VDD.

13.4. Are there any specific coils available for the MLX90109 transceiver?

Melexis has developed an 18mm coil which is used on the evaluation board EVB90109. Please contact your sales channel if

you wish to purchase production quantities.

13.5. What are the recommended pull-up values on DATA and CLOCK pins?

The DATA and CLOCK are open-drain drivers which require external pull-up resistors. The values are not critical therefore, to

reduce the general power consumption, we recommend to use high ohmic (100k ohm) pull up resistances.

                                                                                                                      Page 15 of 17

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

14. Package Information

14.1. Plastic SO8

The device is packaged in a 8 pin lead free SO package (ROHS compliant MSL1/260°C).

                                          E1  E

               1         2  3

                            D

                                      A1      A                                                    

            e                      b                                 L

          all Dimension in mm, coplanarity < 0.1mm

                               D      E1         E    A      A1         e            b      L      a

            min             4.80      3.81    5.80    1.32   0.10    1.27            0.36   0.41   0°

            max             4.98      3.99    6.20    1.72   0.25                    0.46   1.27   8°

          all Dimension in inch, coplanarity < 0.004”

            min             0.189     0.150   0.2284  0.060  0.0040  0.05            0.014  0.016  0°

            max             0.196     0.157   0.2440  0.068  0.0098                  0.018  0.050  8°

                                                                                                       Page 16 of 17

REVISION 011 - JUNE 19, 2017

3901090109
MLX90109

125kHz RFID Transceiver

15. Contact

For the latest version of this document, go to our website at www.melexis.com.

For additional information, please contact our Direct Sales team and get help for your specific needs:

Europe, Africa              Telephone: +32 13 67 04 95

                            Email : sales_europe@melexis.com

Americas                    Telephone: +1 603 223 2362

                            Email : sales_usa@melexis.com

Asia                        Email : sales_asia@melexis.com

16. Disclaimer

The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the

furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special,

consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, includ ing warranties of fitness for particular purpose, non-

infringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services.

The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to

designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.

Users or any third party must further determine the suitability of the Product for its application, including the level of reliability required and determine whether it is fit for a

particular purpose.

The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the Information does not grant, explicitly or implicitly, to

any party any patent rights, licenses, or any other intellectual property rights.

This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.

The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be

suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability applications, such as medical life-support or life-

sustaining equipment are specifically not recommended by Melexis.

The Product(s) may not be used for the following applications subject to export control regulations: the development, product ion, processing, operation, maintenance, storage,

recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons: 2) civil

firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone

or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any

similar violent situation.

The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-and-

conditions.

This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document.

Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016)

ISO/TS 16949 and ISO14001 Certified

                                                                                                                                            Page 17 of 17

      REVISION 011 - JUNE 19, 2017

      3901090109
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Melexis:

MLX90109CDC-AAA-000-SP  MLX90109EDC-AAA-000-TU  MLX90109CDC-AAA-000-RE  MLX90109EDC-AAA-000-

SP  MLX90109EDC-AAA-000-RE  MLX90109CDC-AAA-000-TU
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved