电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

MIOC157004PO112

器件型号:MIOC157004PO112
厂商名称:Oplink(Molex)
厂商官网:http://www.oplink.com
下载文档

器件描述

Mini 4-Port Polarization Insensitive Optical Circulator

MIOC157004PO112器件文档内容

Mini 4-Port Polarization Insensitive
Optical Circulator

MIOC4 Series

Product Description

Oplink's polarization insensitive miniature circulator features excellent optical
characteristics over a wide wavelength range while delivering a compact pack-
age size. It possesses low insertion loss, high isolation, and low PDL making it
an ideal candidate for EDFA, add/drop, dynamic gain equalization, dispersion
compensation and other optical network applications.
Oplink can provide customized designs to meet specialized feature applica-
tions. Also, Oplink offers modular assemblies that integrate other components
to form a full function module or subsystem.

Performance Specificationns

MIOC4 Series                                                   Min  Typical            Max Unit                 Features
                                                                                                                 Compact Package
                                   1310                             1290 ~ 1330                                  Low Insertion Loss
                                                                                                                 Low PDL
Operating Wavelength Range ( Op )  C Band                           1525 ~ 1565                                  High Channel Isolation
                                   L Band                                                                nm      Highly Stable & Reliable
                                                                                                                 Epoxy-free Optical Path
                                                                    1570 ~ 1610                                  Low Dispersion

                                   C+L Band                         1525 ~ 1610                                 Applications
                                                                                                                 Optical Amplification
Insertion Loss (12, 23, 34 @       1310, C or L                     0.6                0.8   dB                  Metropolitan Area Network
Op , TOp , SOP)                    C+L Band                                                                      Dynamic Gain Equalization
                                                                    0.7                0.9                       Dispersion Compensation
                                                                                                                 Laboratory R&D
                                                 1310, C or L                          0.06
Polarization Mode Dispersion (PMD)                                                                   ps

                                                 C+L Band                              0.1

Channel Isolation (21, 32, 43 1310, C or L                     38                            dB

@ Op , TOp , SOP)                  C+L Band                    32

Peak Isolation                                                 50                            dB

Directivity (13, 24)                                           50                            dB

Polarization Dependent Loss (PDL)                                                      0.15  dB

Return Loss (RL)                                               50                            dB

Optical Power Handling                                                                 500   mW

Operating Temperature Rang (Top)                                    0 to +70                 C

Storage Temperature                                                 -40 to +85               C

Fiber Type                                                          Corning SMF-28

Physical Dimensions                                                 () 5.5 x (L) 40.0        mm

Note:
1) The maximum IL is under all states of polarization and within the full operating temperature and wavelength
ranges specified..
2) All the parameters are excluding connectors.

                                                                                                                                            R02.20090114
                                                                                                                                                                    Mini 4-Port Polarization Insensitive Optical Circulator

                                                                                                                                                                                         MIOC4 Series

                                                                                                                       Mechanical Drawing / Package Dimensions (dimension in mm)

46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com www.oplink.com  Ordering Information

                                                                                                                        Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink's OEM
                                                                                                                        design team or account manager for your requirements and ordering information (510) 933-7200.

                                                                                                                       MIOC                             0  4                                   PO

                                                                                                                             Center Channel Wavelength                                         Port Configuration  Fiber Length*   Connector Type
                                                                                                                             1310 = 1310                                                       4 port = 4PO        0.5 meter = H   None = 1
                                                                                                                             C band = 1550                                                                         1.0 meter = 1   FC/PC = 2
                                                                                                                             L band = 1590                                                                         1.5 meters = 5  FC/SPC = 3
                                                                                                                             C+L band = 1570                                                                       2.0 meters = 2  FC/APC = 4
                                                                                                                                                                                                                                   SC/PC = 5
                                                                                                                                                                                               Fiber Type                          SC/SPC = 6
                                                                                                                                                                                               250m bare fiber = 1                 SC/APC = 7
                                                                                                                                                                                               900m loose tube = 2                 ST = 8
                                                                                                                                                                                                                                   LC = 9
                                                                                                                                                                                                                                   MU = A

                                                                                                                             RoHS:
                                                                                                                             1. Add "G" to the end of the above PN for RoHS 6 Requirement.

                                                                                                                             * The tolerance of fiber length is +/-0.1m. 1 meter is standard.
                                                                                                                             * The lead-time for special fiber length will be longer.

                                                                                                                                                                                                                                                                                                                                              R02.20090114
                                                                                                                       Product Lines:  Mux/Demux  Switching/Routing  Coupling/Splitting  Monitoring/Conditioning  Amplification  Transmission  Interconnect  RGB Laser Modules
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved