电子工程世界电子工程世界电子工程世界

产品描述

搜索

MINT1150A1506K01

器件型号:MINT1150A1506K01
器件类别:电源/电源管理   
文件大小:6326.29KB,共9页
厂商名称:All Sensors
标准:
下载文档

器件描述

switching power supplies 150w 15v 6.67a

参数
Manufacturer: SL Power
Product Category: Switching Power Supplies
RoHS: Yes
Open Frame/Enclosed: Open Frame
Output Power Rating: 150 W
Input Voltage: 90 VAC to 264 VAC
Number of Outputs: 1 Output
Output Voltage-Channel 1: 15 V
Output Current-Channel 1: 6.67 A
Commercial/Medical: Medical
Mounting Style: Chassis
Length: 4.02 in
Width: 2 in
Height: 1.18 in
Approvals: EN60601-1, UL60601-1
Brand: Condor / SL Power
Dimensions: 4.02 in L x 2 in W
Series: MINT1150A
Factory Pack Quantity: 10

MINT1150A1506K01器件文档内容

                                                                                                   MINT1150

                                                                                                           150W Single Output
                                                                                                                  Medical Series

                                                                       Features
                                                                        2" x 4" x 1.3" Package
                                                                        For 1U Applications
                                                                        150W w/air, 100W convection cooled
                                                                        Universal Input 90-264 VAC
                                                                        Power Fail/Output Good Signal
                                                                        Approved to CSA/EN/IEC/UL60601-1,

                                                                           3rd Edition
                                                                        2 x MOPP Input to Output Isolation
                                                                        3 Year Warranty
                                                                        RoHS Compliant

Description

The MINT1150 family is a high power density for a power supply in a 2" x 4" size. Approved to EN/IEC/UL60601-1, 3rd
edition, with isolation levels which satisfy the 2 MOPP requirements. The MINT1150 family is ideal for Portable Medical
Devices, and many other applications where medical certifications, power density and cost are critical. The MINT1150
operates at universal input range of 90 to 264Vac and wide temperature range -10C to +70C, delivering full rated output
power up to +50C. In addition, these models feature Power Fail and DC OK signals.

Model Selection

        Model     Volts            Output Current                               Ripple &        Total                OVP
      Number       12V   w/200LFM air Convection*                               Noise**     Regulation          Threshold**

MINT1150A1206K01         12.5A                                  8.33A  0.5%RMS, 1.2% pk-pk      5%              14.0  1.1V

MINT1150A1506K01  15V    10.0A                                  6.67A  0.5%RMS, 1.0% pk-pk  5%                  18.0 1.5V

MINT1150A2406K01  24V    6.25A                                  4.17A  0.5%RMS, 1.0% pk-pk  5%                  28.0 2.5V

MINT1150A4806K01  48V    3.13A                                  2.08A  0.5%RMS, 1.0% pk-pk  5%                  55.0 4.0V

MINT1150A5606K01  56V    2.68A                                  1.79A  0.5%RMS, 1.0% pk-pk  5%                  <59.9V

Notes:  * Maximum output power is 95 Watts for input voltage of 90-105VAC at 50C convection. For input voltage of 105Vac or more, the total power is
           100 Watts at 50C convection.

        ** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors.

General Specifications

        AC Input  100-240Vac, 10%, 47-63Hz, 1                                                   Less than 2 sec. @115Vac (inversely
                  120370Vdc                                           Turn On Time proportional to input voltage and thermistor

                                                                                                 temperature)

        Input Current 115Vac: 2A, 230Vac: 1A                           Hold-up Time >12mS at full load, 120Vac

        Inrush Current 264Vac, cold start: will not exceed 50A         Signals AC Power Fail, DC OK

www.slpower.com                               MINT1150 REV 1.4, 13-NOV-12                                                                              1
                                                                                                         MINT1150

                                                                                                      150W Single Output
                                                                                                             Medical Series

General Specifications (continued)

Input Fuses      F1, F2: 4A, 250Vac fuses provided on all              Overload       Hiccup Mode
                 models                                               Protection

Earth Leakage                                                         Short Circuit Provided - no damage will occur if the output is
         Current <300A@264Vac, 60Hz, NC                                  Protection shorted. Hiccup Mode

     Efficiency 89% typical at 115Vac                                 Overvoltage OVP firing reduces output voltage to <50% of
                                                                        Protection nominal in <50mS. See chart for trip range.
                          150W continuous with 200 lfm airflow, 100W
Output Power convection cooled See chart for specific               Switching       PFC: Variable 30-400kHz.
                                                                      Frequency       Main Converter: Variable 35-180kHz, 65-70kHz
                          voltage model ratings.                                      at full load.
                                                                        Isolation
      Transient 50% load step. i/t: <0.2A/S                                           Input-Output: 4000Vac, 2 x MOPP
     Response Max Volt Deviation = 3%                                                 Input-Ground: 1800Vac, 1 x MOPP
                                                                                      Output-Ground: 500Vac

Ripple and Noise See chart                                                Operating   -10C to +70C
                                                                      Temperature

Output Voltage See chart                                              Temperature Derate output power linearly above 50C to 50%
                                                                            Derating at 70C

       Voltage   +/-5% from nominal                                          Storage  -40C to +85C
Adjustability                                                         Temperature

Minimum Load Not required                                             Altitude        Operating: -500 to 10,000 ft
                                                                                      Non-operating: -500 to 40,000 ft.

Total Regulation +/- 5%. See chart                                    Relative Humidity 5% to 95%, non-condensing

Vibration        Operating: 0.003g/Hz, 1.5grms overall, 3             Shock           Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
                 axes, 10 min/axis                                                    shocks total
                 Non-Operating: 0.026g2/Hz, 5.0grms overall,                          Non-Operating: Half-sine, 40 gpk, 10 ms, 3
                 3 axes, 1 hr/axis                                                    axes, 6 shocks total

Dimensions W: 2.0" x L: 4.0" x H: 1.3"                                Safety Standards EN/CSA/UL/IEC60601-1, 3rd Edition

Weight 183g                                                           MTBF            640,000 hours at 100W convection, 1,500,000
                                                                                      hours at 150W with 200LFM air

Auxiliary Signals                                                     Power Fail:     Goes LOW with 5 mS warning before loss
                                                                                      of output power due to AC failure
      AC Power Fail: During normal operations, stays HIGH.

                                                                                      Open collector logic signal goes and stays HIGH
                                                                      DC OK: 100mS to 500mS after main output reaches

                                                                                      regulation.

www.slpower.com                         MINT1150 REV 1.4, 13-NOV-12                                                                    2
EMI/EMC Compliance                                                      MINT1150

Conducted Emissions                                                             150W Single Output
Radiated Emissions                                                                     Medical Series
Static Discharge Immunity
Radiated RF Immunity                     EN55011/22 Class B, FCC Part 15, Subpart B, Class B
EFT/Burst Immunity                       EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin
Line Surge Immunity                      EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge
Conducted RF Immunity                    EN61000-4-3, 3V/m. Criteria A
Power Frequency Magnetic Field Immunity  EN61000-4-4, 2kV/5kHz, Criteria A
Voltage Dip Immunity                     EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A
Line Harmonic Emissions                  EN61000-4-6, 3Vrms, Criteria A
Flicker Test                             EN61000-4-8, 3A/m, Criteria A
                                          EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles;
Mechanical Drawing                        Criteria A
                                          EN61000-3-2, Class A, B, C, & D
                                          EN61000-3-3, Complies (dmax<6%)

www.slpower.com                           MINT1150 REV 1.4, 13-NOV-12                                             3
Connector Information                                                                                MINT1150

       Input Connector               Ground            DC Output Connector                        150W Single Output
                J100                   J101                        J200                                  Medical Series

PIN 1) AC LINE          0.187" FASTON TAB           PIN 1) +Vout PIN 4) -Vout                           Signal Connector
PIN 2) EMPTY                                        PIN 2) +Vout PIN 5) -Vout                                    J300
PIN 3) AC NEUTRAL       Mating Connector:           PIN 3) +Vout PIN 6) -Vout
                        Molex 01-90020005                                                            PIN 1) PF/DC OK
Mating Connector:                                   Mating Connector:                                PIN 2) Common
Molex 09-50-3031                                    AMP 640250-6
Pins= 08-52-0072                                    Pins = 640252-1                                  Mating Connector:
                                                                                                     Molex 1375820-2
                                                                                                     Pins = 1375819

Power Fail/DC OK Signals J300

                                      J300Pin 1

                                      J300 Pin 2

                 AC POWER FAIL SIGNAL                                            DC OK SIGNAL

Isolation Specifications                            Conditions/Description       Min   Nom        Max  Units

                Parameter                                    Input/Ground        1800  2 MOPP           Vac
          Insulation Safety Rating                            Input/Output       4000  1 MOPP           Vac
                                                            Output/Ground        500                    Vac
      Electric Strength Test Voltage                                                      N/A
                                                             Input/Ground
                                                              Input/Output                     -  -
                                                            Output/Ground

www.slpower.com                                     MINT1150 REV 1.4, 13-NOV-12                                           4
                                                                                                                             MINT1150

                                                                                                                          150W Single Output
                                                                                                                                 Medical Series

Input Specifications

All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.

Parameter                           Conditions/Description                 Min  Nom                                       Max          Units
                                                                                                                          264           Vac
Input Voltage                                                              90   115/230                                                 Vac
                                                                                                                           63           Vac
Turn-On Input Voltage               Ramping up                                                                      82.7   50            Hz
                                                                                                                            -             A
Turn-Off Input Voltage              Ramping down                                                                    67.0
                                                                                                                            -            %
Input Frequency                                                            47   50/60

Inrush Current Limitation           264Vac, cold start                     -                                        -

Power Factor                              Vi nom, Io nom                   0.9                                      -
  Efficiency
                                          Vi nom, Io nom                   -                                        89%
                                    MINT1150A1206K01
                                    MINT1150A2406K01
                                    MINT1150A4806K01
                                    MINT1150A5606K01

Protection                                  Conditions/Description         Min  Nom                                       Max          Units
                                                  Not user accessible
               Parameter                                                                                                  2            KV (CM)
                   Input Fuse              2KV(CM) and 1KV(DM) surge
        Input Transient Protection                        No-load                                                         Normal

                     Output                            Short Circuit                                                      Hiccup Mode
                                                         Overload
          Overvoltage Protection                        Latch style                        Hiccup Mode
       Over temperature Protection                                              See Models chart for trip ranges
                                    Automatic power shutdown at TC =155C

Characteristic Curves

Output vs. Temperature
100W convection cooled and 150W continuous with 200 LFM airflow, Derating output power to 50% at 70C.

www.slpower.com                     MINT1150 REV 1.4, 13-NOV-12                                                                                  5
                                                                            MINT1150

                                                                                                             150W Single Output
                                                                                                                    Medical Series

Efficiency vs. Loading

The high efficiency is achieved by using LLC technology, PFC topology minimizing switching losses. Synchronous MOSFET or SCHOTTKY diode is
used as rectifier in MINT1150 family.

Ripple & Noise

To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with
0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW.

                 24V OUT, NO LOAD, 90VAC, 60HZ   24V OUT, FULL LOAD, 90VAC, 60HZ

                 24V OUT, NO LOAD, 264VAC, 50HZ  24V OUT, FULL LOAD, 264VAC, 50HZ

www.slpower.com  MINT1150 REV 1.4, 13-NOV-12                                                                                                           6
                                                                            MINT1150

                                                                                                             150W Single Output
                                                                                                                    Medical Series

Output Transient Response

50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/Sec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY.

24V OUT, 120VAC, 25% TO 75% LOAD STEP  24V OUT, 240VAC, 25% TO 75% LOAD STEP

Output Overload Characteristic

Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention.

                 24V OUT, 90VAC                               24V OUT, 264VAC

Short Circuit Protection

Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted.

                 24V OUT, 90VAC                               24V OUT, 264VAC

www.slpower.com                  MINT1150 REV 1.4, 13-NOV-12                                                                                            7
                                                                                                     MINT1150

                                                                                                  150W Single Output
                                                                                                         Medical Series

Overvoltage Protection

OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges.

                                   24V OUT, NO LOAD

Turn On Time

                 90VAC, FULL LOAD                                                                 264VAC, FULL LOAD

Hold Up Time

                                   120VAC, FULL LOAD

Data Sheet 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.

www.slpower.com                    MINT1150 REV 1.4, 13-NOV-12                                                                                                                                           8
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

SL Power:

  MINT1150A4806K01 MINT1150A5606K01 MINT1150A1206K01 MINT1150A2406K01 MINT1150A1506K01
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved