器件描述

Isolated DC/DC Converters 270 Vin, 10 Vout, 100 W, M Product Grade

参数

产品属性属性值
产品种类:
Product Category:
Isolated DC/DC Converters
制造商:
Manufacturer:
Vicor
商标:
Brand:
Vicor

MI-26M-MW-F4器件文档内容

                                                                                                                 DC-DC Converters

                                                                                                                                                       MI-200

                                                                                                                                50 to 100 Watts

Features & Benefits                                 Packaging Options

•  Inputs:                                          Standard: Slotted baseplate

   ■■28VDC per MIL-STD-704D/E/F

   ■■155VDC per MIL-STD-1399A                       SlimMod: Flangeless baseplate, option suffix:                   -   S

   ■■270VDC per MIL-STD-704D/E/F                    Example: MI - 2XX - XX - S

•  Single output: 2 – 48VDC                         FinMod: Finned heat sink, option suffix:

•  Up to 23W/in3                                    - F1, -F2, -F3 and - F4

•  MIL-STD-810 environments                         Examples:

•  Up to 90% efficiency                             MI - 2XX - XX -F1, 0.25” fins, longitudinal

                                                    MI - 2XX - XX -F2, 0.50” fins, longitudinal

•  Remote sense                                     MI - 2XX - XX -F3, 0.25” fins, transverse

•  Current limit                                    MI - 2XX - XX -F4, 0.50” fins, transverse

•  OVP and thermal shutdown                         Converter Selection Chart

•  Power boosters for                               MI-2

   higher power outputs

•  ZCS power architecture                           Semi-custom modules available, consult factory.

•  Low noise FM control                                         Input Voltage

•  Size: 4.6” x 2.4” x 0.5”

   (116,8 x 61,0 x 12,7 mm)                         Nominal                        Range          Transient [a]         Notes

                                                             2 = 28V          18 – 50V [b]           60V                28VDC input per MIL-STD 704D/E/F

Product Highlights                                           5 = 155V         100 – 210V          230V                  155VDC input per MIL-STD-1399A

The MI-200 family of DC-DC converters is                     6 = 270V         125 – 400V [c]      475V                  270VDC input per MIL-STD-704D/E/F

designed for applications utilizing distributed              7 = 165V         100 – 310V             n/a

power architectures. Based on Vicor’s               [a] Transient voltage for 1 second.

VI-200 / VI-J00 family of zero-current              [b] 16V operation at 75% load.                               Product Grade Temperature (°C)

switching, component level DC-DC converters,        [c] These units rated at 75% load from

the MI-200 family offers exceptional                         125 – 150VIN: MI-J6Z-xY, MI-J6Y-xY,                 Operating      Storage

performance in terms of power density,                       MI-J60-xY                                    I      =  –40 to +85  I = –55 to +100

efficiency, noise, ease of use, and reliability.

                                                                Output Voltage                            M      =  –55 to +85  M = –65 to +100

Fully encapsulated in Vicor’s industry standard                                                                     Overtemperature shutdown 95°C typical

package, the MI-Series meets MIL-STD-810

environmental requirements for humidity,                     Z  =  2.0V            1    =  12V                             (recycle power to restart)

fungus, salt-fog, explosive atmosphere,                      Y  =  3.3V            P    =  13.8V

acceleration, vibration and shock.                           0  =  5.0V            2    =  15V                   Output Power/Current VOUT

Standard features, such as wide output                       X  =  5.2V            N    =  18.5V                    ≥5V                                <5V

trimming/programming, current limiting,                      W  =  5.5V            3    =  24V                      Y = 50W     Y = 10A

remote sense, output inhibit, and latching                                                                          X = 75W     X = 15A

OVP and OTP combine to offer the highest                     V  =  5.8V            L    =  28V                      W = 100W    W = 20A

degree of protection, versatility, and reliability           T  =  6.5V  [d]       J    =  36V                      V=     —    V = 30A

for power systems.                                           R  =  7.5V  [d]       K    =  40V

                                                                                                                        For additional output power,

                                                             M  =  10V             4    =  48V                   100W and 75W booster modules available

                                                    [d]                                                             Change (MI-2xx-xx) to (MI-Bxx-xx)

                                                             75W   max power  for  28V  input

MI-200 DC-DC Converters                             Rev 1.6                        vicorpower.com

Page 1 of 7                                         06/2017                        800 927.9474
                                                                                                                                                 MI-200

Converter Specifications

(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)

Input Specifications

Parameter                   Min                Typ                             Max                       Units      Test Conditions

Inrush charge                                                120 x 10-6                      200 x 10-6              Coulombs     Nominal line

Input reflected                                              10%                                                                        IIN     Nominal line, full load

ripple current – pp

(( )) I         nput ripple rejection                           32         00++2200 LLoogg         VVVVOOIINNUUTT                   ddBB                                    120Hz, nominal line

                                                                                                                    2400Hz, nominal line

No load power dissipation                                    1.35                            2                         Watts

Output Characteristics

Parameter                   Min                Typ                             Max                       Units      Test Conditions

Setpoint accuracy                                            0.5%                            1%                        VNOM

                                                             0.05%                           0.2%                      VNOM       LL to HL, 10% to Full Load

Load/line regulation

                                                             0.2%                            0.5%                      VNOM       LL to HL, No Load to 10%

Output temperature drift                                     0.01                            0.02                    % / °C       Over rated temperature

Long term drift                                              0.02                                                                  %/1K hours

                                                             100                             150                       mV         Whichever is greater

Output ripple – pp                                                                                                  20MHz bandwidth

                                                             1.0%                            1.5%                      V  NOM

Trim range [a]              50%                 110%                                                                   VNOM

Total remote                          0.5                         Volts

sense compensation

OVP set point [b]           115%               125%                            135%                      VNOM       latching

Current limit               105%                                                             125%                      INOM       Automatic restart

Short circuit current [c]   20%                                                              130%                      INOM

[a] 10V to 15V outputs, standard trim range ±10%. Consult factory for wider trim range.

3.3V output trim range 2.20 to 3.63V

[b] No over temperature or voltage protection in booster modules

[c] Output voltages of 5V or less incorporate foldback current limiting; outputs of 10V and above provide constant  current limiting.

Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application  information,

please refer to output connections on page 5.

Control Pin Specifications

Parameter                   Min                Typ                             Max                       Units      Test Conditions

Gate out impedance                                                    50                                                             Ohms

Gate in impedance                                            1000                                                                    Ohms

Gate in open circuit voltage                                          6                                                              Volts      Use open collector

Gate in low threshold       0.65                                                                                              Volts

Gate in low current                                                                                 6                         mA

Power sharing accuracy      0.95                                                             1.05

MI-200 DC-DC Converters                        Rev 1.6                                   vicorpower.com

Page 2 of 7                                    06/2017                                   800 927.9474
                                                                                                                                        MI-200

Converter Specifications (Cont.)

(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)

Dielectric Withstand Characteristics

Parameter                     Min        Typ                                   Max                 Units      Test Conditions

Input to output               3,000                                                                                     VRMS       Baseplate earthed

Output to baseplate           500                                                                                       VRMS

Input to baseplate            1,500                                                                                     VRMS

Input to output capacitance                                     50                           75                  pF

Thermal Characteristics

Parameter                     Min        Typ                                   Max                 Units      Test Conditions

Efficiency                                             80 – 90%                       

Baseplate to sink                                      0.07                                                                  °C/Watt      With thermal pads

thermal impedance

Thermal shutdown [d]           90                 95                           105                 °C         Cool and recycle power

(Drivers only)                                                                                                                                   to restart

[d] No over temperature or voltage protection in booster modules

Enviornmental – MIL-STD-810D

Parameter                     Min        Typ                                   Max                 Units      Test Conditions

Altitude - method 500.2      70,000                                                                                     feet       Procedure II

Humidity - method 507.2      86 / 240                                                                                 % / hours    Procedure I, cycle 1

Acceleration - method 513.3    9                                                                                        g          Procedure II

Vibration - method 514.3       20                                                                                       g          Procedure I, category  6

Shock - method 516.3           40                                                                                       g          Procedure I

Reliability – MIL-HDBK-217F (MI-22L-MW)

Parameter                     Min        Typ                                   Max                 Units      Test Conditions

25°C Ground Benign: G.B.                               3,552                                                                 1,000 hours

50°C Naval Sheltered: N.S.                             639                                                                   1,000 hours

65°C Airborne Inhabited                  501                                                                   1,000 hours

Cargo: A.I.C.               

Mechanical Specifications

Parameter                     Min        Typ                                   Max                 Units      Test Conditions

Weight                        7.2                 7.3                          7.4               Ounces

                              205        208                                   210               Grams

MI-200 DC-DC Converters                  Rev 1.6                                   vicorpower.com

Page 3 of 7                              06/2017                                   800 927.9474
                                                                                                                                                         MI-200

Converter Specifications (Cont.)

Product Grade Specifications

Parameter                                                                   I-Grade                                                          M-Grade

Storage temperature                                                         -55°C to +100°C                                       -65°C to +100°C

Operating temperature (baseplate)                                           -40°C to +85°C                                        -55°C to +85°C

Power cycling burn-in                                                   12 hours, 29 cycles                                       96 hours, 213 cycles

Temperature cycled with power off                                           12 cycles                                                        12 cycles

17°C per minute rate of change                                              -65°C to +100°C                                       -65°C to +100°C

Test data supplied at these temperatures [e]                                -40°C, +80°C                                          -55°C, +80°C

Warranty                                                                    2 years                                                          2 years

Environmental compliance                                                    MIL-STD-810                                           MIL-STD-810

Derating                                                                NAVMAT P-4855-1A                                          NAVMAT P-4855-1A

[e] Test data available for review or download    from  vicorpower.com

Maximum Capacitance, Rated Output Voltage <5V

Rated VOUT (V)                     IOUT Rating (A)                          CMAX (µF)                    IOUT Rating (A)                      CMAX (µF)

2 to <3                                         ≤10                         1500                         >10 to 40                            5000

3 to <5                                         ≤10                         1000                         >10 to 40                            5000

Maximum Capacitance, Rated Output Voltage ≥5V

Rated VOUT (V)                     POUT Rating (W)                          CMAX (µF)                    POUT Rating (W)                      CMAX (µF)

5 to <7.5                                       ≤50                         1000                         >50 to 100                           1500

7.5 to <10                                      ≤50                         400                          >50 to 100                           700

10 to <28                                       ≤50                         400                          >50 to 100                           500

>28                                             ≤50                         150                          >50 to 100                           250

Enviornmental Qualifications

Parameter                          Qualification

                                   MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40K ft.).

Altitude                           MIL-STD-810D, Method 500.2, Procedure II, 40,000ft., 1000 – 1500ft./ min. to 70,000ft., unit functioning

Explosive Atmosphere               MIL-STD-810C, Method 511.1, Procedure I

                                   MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20g

Vibration                          MIL-STD-810D, Method 514.3 random: 10 – 300Hz @ 0.02g2/Hz, 2000Hz @ 0.002g2/ Hz, 3.9 total Grms

                                   3 hr­s/axis. Sine: 30Hz @ 20g, 60Hz @ 10g, 90Hz @ 6.6g, 120Hz @ 5.0g, 16.0 total Grms, 3 axes

                                   MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6db/octave, 7.7G rms, 1hr/axis

                                   MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40g

                                   MIL-STD-202F, Method 213B, 18 pulses, 60g, 9msec

Shock

                                   MIL-STD-202F, Method 213B, 75g, 11ms saw tooth shock

                                   MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet

Acceleration                       MIL-STD-810D, Method 513.3, Procedure II Operational test, 9g for 1 minute along 3 mutually perpendicular  axes

Humidity                           MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity

Solder Test                        MIL-STD-202, Method 208, 8hr. aging

Fungus                             MIL-STD-810C, Method 508.1

MI-200 DC-DC Converters                                 Rev 1.6                               vicorpower.com

Page 4 of 7                                             06/2017                               800 927.9474
                                                                                                                                 MI-200

Basic Module Operation

                                                     C1a                                          C2a

                                     F1                       +IN    Zero Current +OUT

                                       C3                            Switching
                                                                     Converter
                                                              –IN               –OUT

                                                     C1b                                          C2b

C3 (µF)      =  400

                VIN Minimum

Figure 1 —   Basic module operation  requires fusing, grounding,     bypassing capacitors.*  See  Design Guide  &  Applications  Manual.

Output Connections and Considerations                                Storage

The permissible load current [e] must never be exceeded during       Vicor products, when not installed in customer units, should

normal, abnormal or test conditions. Converters subject to           be stored in ESD safe packaging in accordance with

dynamic loading exceeding 25% of rated current must be               ANSI/ESD S20.20, “Protection of Electrical and Electronic

reviewed by Vicor Applications Engineering to ensure that the        Parts, Assemblies and Equipment” and should be maintained

converter will operate properly.                                     in a temperature controlled factory/warehouse environment

Under dynamic load, light load, or no load conditions, the           not exposed to outside elements controlled between the

converter may emit audible noise. Converters that utilize remote     temperature ranges of 15ºC and 38ºC. Humidity shall not be

sense may require compensation circuitry to offset the phase         condensing, no minimum humidity when stored in an ESD

lag caused by the external output leads and load impedance.          compliant package.

Remote Sense leads must be protected for conditions such as

lead reversal, noise pickup, open circuit, or excessive output lead

resistance between the sense point and the converters output

terminals. For applications that may draw more than the rated

current, a fast acting electronic circuit breaker must be utilized

to protect the converter. Under no circumstance should the

rated current be exceeded. Utilizing or testing of current limit or

short circuit current will damage the converter. Ensure that the

total output capacitance connected to the converter does not

exceed the limits on Page 4.

[e] Permissible load current:  Nominal Power Rating

                                  Nominal VOUT

MI-200 DC-DC Converters                         Rev 1.6              vicorpower.com

Page 5 of 7                                     06/2017              800 927.9474
                                                                                                                                                  MI-200

Mechanical Drawing                             VI-200 Mechanical Drawing

                                               4.60
                                            (116,8)
                                               3.60                           Standard                               RoHS
                       .50
                                               (91,4)                         0.080 (2,0) Dia (2) places             0.080 (2,0) Dia (2) places
                       (12,7)  1.80                                           Solder plate over copper alloy         Matte tin over copper alloy

             .30±.015          (45,7)
(7,6)±(0,38)
                                                                                                                     Pin #   Function

                                                                                                                     1       +In

                       4                                              9                                              2       Gate In

                                                                                                                     3       Gate Out

             2.10      3                                              8                                              4       -In

                                            MVII--220000              7                      1.40                    5       +Out
(53,3)                                                                                1.00 (35,6)
                                                                      6          .70 (25,4)                          6*      +Sense
                       2                                                 .40  (17,8)
                                                                                                                     7*      Trim
                       1                                              5  (10,2)

                                                                                      .35±.015                       8*      -Sense
                                                                                      (8,9)±(0,38)
                                                                                                                     9       -Out

             .15                      FULL  R                                                                 *      Do not  connect on  booster  modules

             (3,8)             .15                        Product ID          Standard                               RoHS

                               (3,8)                      this surface   .040 (1,0) Dia (7) places                   .040 (1,0) Dia (7) places

                                                                              Solder plate over copper        alloy  Matte tin over copper alloy

                                                                                                                             2.40
                                                                                                                             (61,0)
                                                                                                   .30
                                               4.20                      .22                       (7,6) Min                1.75
                                               (106,7)                                                                            Max.
                                                                         (5,6) MIN                                       (44,5)

                                                                                 .50         +.030 (0,76)
                                                                                 (12,7)      -.000 (0)

                                                                                                   .01

             .12                                                                                              Aluminum Base
             (3,0)

Note: For alternate package options refer to the mechanical drawing page of vicorpower.com

MI-200 DC-DC Converters                              Rev 1.6                          vicorpower.com

Page 6 of 7                                          06/2017                          800 927.9474
                                                                                                                                      MI-200

Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and

accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom

power systems.

Information furnished by Vicor is believed to be accurate and reliable.  However, no responsibility is assumed by Vicor for its use.  Vicor

makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication.        Vicor reserves

the right to make changes to any products, specifications, and product descriptions at any time without notice.       Information published by

Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.

Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty.            Except where

mandated by government requirements, testing of all parameters of each product is not necessarily performed.

Specifications are subject to change without notice.

Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information.

Vicor’s Standard Terms and Conditions and Product Warranty

All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage

(http://www.vicorpower.com/termsconditionswarranty) or upon request.

Life Support Policy

VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE

EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION.                               As used

herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and

whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to

result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform

can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.  Per Vicor Terms

and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies

Vicor against all liability and damages.

Intellectual Property Notice

Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the

products described in this data sheet.    No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property

rights is granted by this document.     Interested parties should contact Vicor’s Intellectual Property Department.

                                                      Vicor Corporation

                                                      25 Frontage Road

                                                      Andover, MA, USA 01810

                                                      Tel: 800-735-6200

                                                      Fax: 978-475-6715

                                                                         email

                                          Customer Service: custserv@vicorpower.com

                                          Technical Support: apps@vicorpower.com

MI-200 DC-DC Converters                   Rev 1.6                               vicorpower.com

Page 7 of 7                               06/2017                               800 927.9474
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Vicor:

MI-25J-MY  MI-220-IW    MI-25N-IW-F4  MI-220-MW  MI-22L-MW  MI-253-MY-S  MI-25T-IW-S

小广播

MI-26M-MW-F4器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved