19-5622; Rev 0; 1/11

EVAALVUAAILTAIOBNLEKIT

                                       ISO 15693-Compliant 64-Bit UID

                        General Description                                                       Features           MAX66100

The MAX66100 contains a 64-bit unique identifier (UID)    ♦  Fully Compliant with ISO 15693 and ISO 18000-3

and a 13.56MHz ISO 15693 RF interface in a single            Mode 1 Standard

chip. The UID is revealed during the inventory process.   ♦  13.56MHz ±7kHz Carrier Frequency

The MAX66100 supports all ISO 15693-defined data          ♦  64-Bit Unique, Factory-Programmed UID

rates, modulation indices, subcarrier modes, the select-

ed state, application family identifier (AFI), and data   ♦  Supports AFI and DSFID Function

storage format identifier (DSFID). AFI and DSFID are      ♦  Write: 10% or 100% ASK Modulation Using 1/4

factory programmed with customer-supplied data.              (26kbps) or 1/256 (1.6kbps) Pulse-Position Coding

                                       Applications       ♦  Read: Load Modulation Using Manchester Coding

Driver Identification (Fleet Application)                    with 423kHz and 484kHz Subcarrier in Low

                                                             (6.6kbps) or High (26kbps) Data-Rate Mode

Access Control                                            ♦  Compatible with Existing ISO 15693 Products on

Asset Tracking                                               the Market

                                                          ♦  Powered Entirely Through the RF Field

                                                          ♦  Operating Temperature: -25°C to +50°C

                                                                              Ordering Information

Mechanical Drawings appear at end of data sheet.             PART             TEMP RANGE          PIN-PACKAGE

                                                          MAX66100E-000AA+    -25°C to +50°C      ISO Card

                                                          MAX66100K-000AA+    -25°C to +50°C      Key Fob

                                                          +Denotes a lead(Pb)-free/RoHS-compliant package.

                                                                         Typical Operating Circuit

                      13.56MHz READER                        MAGNETIC

                                                             COUPLING

                                       TX_OUT                                           MAX66100

                        TRANSMITTER                                           IC LOAD

                                                                              SWITCHED

                                       RX_IN                 ANTENNA          LOAD

                      ________________________________________________________________ Maxim Integrated Products  1

For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,

or visit Maxim’s website at www.maxim-ic.com.
          ISO 15693-Compliant 64-Bit UID

MAX66100  ABSOLUTE MAXIMUM RATINGS

          Maximum Incident Magnetic Field Strength ..........141.5dBµA/m                          Relative Humidity ..............................................(Water Resistant)

          Operating Temperature Range ...........................-25°C to +50°C                   Storage Temperature Range ...............................-25°C to +50°C

          Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional

          operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to

          absolute maximum rating conditions for extended periods may affect device reliability.

          ELECTRICAL CHARACTERISTICS

          (TA = -25°C to +50°C.) (Note 1)

                    PARAMETER                SYMBOL                              CONDITIONS                                    MIN         TYP    MAX     UNITS

          RF INTERFACE

          Carrier Frequency                  fC        (Notes 1, 2)                                                            13.553     13.560  13.567           MHz

          Activation Field Strength          HMIN      At 25°C, MAX66100E                                                                  110.5          dBμA/m

          (Note 3)                                     At 25°C, MAX66100K                                                                  122.0

          Maximum Field Strength             HMAX      At 25°C (Note 3)                                                                    137.5          dBμA/m

          Power-Up Time                      tPOR      (Notes 3, 4)                                                                               1.0                    ms

          Note 1: System requirement.

          Note 2: Production tested at 13.56MHz only.

          Note 3:   Guaranteed by simulation; not production tested.

          Note 4:   Measured from the time at which the incident field is present with strength greater than or equal to H(MIN) to the time at

                    which the MAX66100’s internal power-on reset signal is deasserted and the device is ready to receive a command frame.

                    Not characterized or production tested; guaranteed by simulation only.

                                     Detailed Description                                                     Unique Identification Number (UID)

          The MAX66100 contains a 64-bit unique identifier (UID)                                  Each MAX66100 contains a factory-programmed and

          and a 13.56MHz ISO 15693 RF interface in a single                                       locked identification number that is 64 bits long

          chip. The UID is accessed through standard ISO                                          (Figure 3). The lower 36 bits are the serial number of the

          15693 function commands. The data rate can be as                                        chip. The next 8 bits store the device feature code, which

          high as 26.69kbps. The MAX66100 supports AFI and                                        is 01h. Bits 45 to 48 are 0h. The code in bit locations 49 to

          DSFID. Applications of the MAX66100 include driver                                      56 identifies the chip manufacturer, according to ISO/IEC

          identification (fleet application), access control, and                                 7816-6/AM1. This code is 2Bh for Maxim. The code in the

          asset tracking.                                                                         upper 8 bits is E0h. The UID is read accessible through

                                                                                                  the Inventory and Get System Information commands.

                                                       Overview

          Figure 1 shows the relationships between the major                                                                   INTERNAL SUPPLY

          control and memory sections of the MAX66100.

          Figure 2 shows the applicable ISO 15693 commands                                                                     VOLTAGE

          and their purpose. The network function commands                                                                   REGULATOR

          allow the master to identify all slaves in its range and to

          change their state, e.g., to select one for further com-

          munication. The protocol for these is described in the                                              RF

          Network Function Commands section. All data is read                                                 FRONT-           ISO 15693

          and written least significant bit (LSb) first, starting with                                        END

          the least significant byte (LSB).                                                                                    FRAME

                                                                                                                      DATA     FORMATTING         UID, AFI, DSFID

                                             Parasite Power                                                           fc       AND

          As a wireless device, the MAX66100 is not connected to                                                               ERROR

          any power source. It gets the energy for operation from                                                              DETECTION

          the surrounding RF field, which must have a minimum                                                      MODULATION

          strength as specified in the Electrical Characteristics

          table.                                                                                  Figure  1.  Block Diagram

          2  _______________________________________________________________________________________
                                                 ISO 15693-Compliant 64-Bit UID

                                                                             MAX66100                                                       MAX66100

                              COMMAND TYPE:          AVAILABLE COMMANDS:               DATA FIELD AFFECTED:

                                                     INVENTORY                         UID, AFI, DSFID, ADMINISTRATIVE DATA

                              NETWORK                STAY QUIET                        UID

                              FUNCTION COMMANDS      SELECT                            UID

                                                     RESET TO READY                    UID

                              MEMORY FUNCTION        GET SYSTEM INFORMATION            UID, AFI, DSFID, CONSTANTS

                              COMMANDS

Figure 2. ISO 15693 Commands Overview

MSb                                                                                                                               LSb

64                    57  56            49       48              45  44                      37  36                                   1

         E0h                  2Bh                    0h                  FEATURE CODE (01h)                  36-BIT IC SERIAL NUMBER

Figure 3. 64-Bit UID

    SOF               1 OR MORE DATA BYTES                           CRC (LSB)               CRC (MSB)                       EOF

                                                                                                                                  TIME

Figure 4. ISO 15693 Frame Format

              ISO 15693 Communication                                     SOF/EOF timing, refer to ISO 15693-2, Sections 7.2,

                                                     Concept              7.3, and 8.

The communication between the master and the                              The path from master to slave uses amplitude modu-

MAX66100 (slave) is based on the exchange of data                         lation (Figure 5); the modulation index can be either in

packets. The master initiates every transaction; only                     the range of 10% to 30% or 100% (ISO 15693-2,

one side (master or slaves) transmits information at any                  Section 7.1). The standard defines two pulse-position

time. Each data packet begins with a start-of-frame                       coding schemes that must be supported by a compli-

(SOF) pattern and ends with an end-of-frame (EOF)                         ant device. Scheme A uses the “1 out of 256” method

pattern. A data packet with at least 3 bytes between                      (Figure 6), where the transmission of 1 byte takes

SOF and EOF is called a frame (Figure 4). The last 2                      4.833ms, equivalent to a data rate of 1655bps. The

bytes of an ISO 15693 frame are an inverted 16-bit                        location of a modulation notch during the 4.833ms con-

CRC of the preceding data generated according to the                      veys the value of the byte. Scheme B uses the “1 out of

CRC-16-CCITT polynomial. This CRC is transmitted with                     4” method (Figure 7), where the transmission of 2 bits

the LSB first. For more details on the CRC-16-CCITT,                      takes 75.52µs, equivalent to a data rate of 26,484bps.

refer to ISO 15693 Part 3, Annex C.                                       The location of a modulation notch during the 75.52µs

                                                                          conveys the value of the 2 bits. A byte is transmitted as

For transmission, the frame information is modulated on                   a concatenation of four 2-bit transmissions, with the

a carrier frequency, which is 13.56MHz for ISO 15693.                     least significant 2 bits of the byte being transmitted

The subsequent paragraphs are a concise description                       first. The transmission of the SOF pattern takes the

of the required modulation and coding. For full details                   same time as transmitting 2 bits in Scheme B. The SOF

including graphics of the data coding schemes and                         pattern has two modulation notches, which makes it

                      _______________________________________________________________________________________                            3
          ISO 15693-Compliant 64-Bit UID

MAX66100  distinct from any 2-bit pattern. The position of the sec-                  and high (approximately 26,500bps). The Data_rate_flag

          ond notch tells whether the frame uses the “1 out of                       bit in the request data packet specifies the response

          256” or “1 out of 4” coding scheme (Figures 8 and 9,                       data rate. The data rate varies slightly depending on the

          respectively). The transmission of the EOF pattern                         use of one or two subcarriers. The LSb is transmitted

          takes 37.76µs; the EOF is the same for both coding                         first. A compliant device must support both subcarrier

          schemes and has one modulation notch (Figure 10).                          modes and data rates.

          The path from slave to master uses one or two subcar-                      In the single subcarrier case, the subcarrier frequency

          riers, as specified by the Subcarrier_flag bit in the                      is 423.75kHz. One bit is transmitted in 37.76µs (high

          request data packet. The standard defines two data                         data rate) or 151µs (low data rate). The modulation is

          rates for the response, low (approximately 6600bps)                        the on/off key. For a logic 0, the subcarrier is on during

                                                                                     the first half of the bit transmission time and off for the

                                                                                     second half. For a logic 1, the subcarrier is off during

             CARRIER                                                                 the first half of the bit transmission time and on for the

             AMPLITUDE                                                               second half. See Figure 11 for more details.

                                                                                     In the two subcarrier cases, the subcarrier frequencies

             100%                                                                    are 423.75kHz and 484.28kHz. The bit duration is the

                                                                                     same as in the single subcarrier case. The modulation

                                                                                     is equivalent to binary FM. For a logic 0, the lower sub-

                                                                                     carrier is on during the first half of the bit transmission

                                                                                     time, switching to the higher subcarrier for the second

                                                                                     half. For a logic 1, the higher subcarrier is on during the

                                                                         t           first half of the bit transmission time, switching to the

                                                                                     lower subcarrier for the second half. See Figure 12 for

                                                                                     details. The transmission of the SOF pattern takes the

                                                                                     same time as transmitting 4 bits (approximately 151µs

                                                                                     at a high data rate or approximately 604µs at a low data

                                                                                     rate). The SOF is distinct from any 4-bit data sequence.

                                                                                     The EOF pattern is equivalent to a SOF being transmit-

                                                                                     ted backwards. The exact duration of the SOF and EOF

                                                                                     varies slightly depending on the use of one or two sub-

          Figure 5. Downlink Modulation (e.g., Approximately 100%                    carriers (see Figures 13 and 14, respectively).

          Amplitude Modulation)

                   PULSE-                                                      ~ 9.44μs

             MODULATED

                   CARRIER                                                     ~ 18.88μs

                            0  1  2  3  4  .  .  .  .           .  2  .     .  .  .      .  .   .  .  .  .  .  .  .  .  .  .  .  .  .  .  2  2  2  2

                                                                   2                                                                      5  5  5  5

                                                                   5                                                                      2  3  4  5

                                                                                     ~ 4.833ms

          Figure 6. Downlink Data Coding (Case “1 Out of 256”)

          4  _______________________________________________________________________________________
                                                      ISO 15693-Compliant                         64-Bit    UID

            PULSE POSITION “00”                                                                                  MAX66100

            ~ 9.44μs             ~ 9.44μs

                                                                            ~ 75.52μs

            PULSE POSITION “01” (1 = LSb)

                                 ~ 28.32μs                       ~ 9.44μs

                                                                            ~ 75.52μs

            PULSE POSITION “10” (0 = LSb)

                                                      ~ 47.20μs                        ~ 9.44μs

                                                                            ~ 75.52μs

            PULSE POSITION “11”

                                                                 ~ 66.08μs                        ~ 9.44μs

                                                                            ~ 75.52μs

Figure  7.  Downlink Data Coding (Case      “1  Out of 4”)       (Carrier Not Shown)

            ~ 9.44μs                                                                              ~ 9.44μs

                                           ~ 37.76μs                                   ~ 37.76μs

Figure  8.  Downlink SOF for “1 Out of 256” Coding (Carrier Not Shown)

            _______________________________________________________________________________________         5
          ISO 15693-Compliant 64-Bit UID

MAX66100                       ~ 9.44μs                                            ~ 9.44μs  ~ 9.44μs

                                                 ~ 37.76μs                                             ~ 37.76μs

          Figure 9. Downlink SOF for “1 Out of 4” Coding (Carrier Not Shown)

                                                                                   ~ 9.44μs  ~ 9.44μs

                                                                        ~ 37.76μs

          Figure 10. Downlink EOF (Identical for Both Coding Schemes) (Carrier Not Shown)

                                                                                             TRANSMITTING A ZERO

                                                 423.75kHz, ~ 18.88μs                        ~ 18.88μs

                                                                        ~ 37.76μs

                                                 TRANSMITTING A ONE

                                                 ~ 18.88μs                                   423.75kHz, ~ 18.88μs

                                                                        ~ 37.76μs

          Figure  11.  Uplink  Coding,   Single  Subcarrier Case (High  Data-Rate Timing)

          6  _______________________________________________________________________________________
                                         ISO 15693-Compliant 64-Bit UID

                                         423.75kHz, ~ 18.88μs                        484.28kHz, ~ 18.58μs                                      MAX66100

                                                                                     TRANSMITTING A ZERO

                                                               ~ 37.46μs

                                         484.28kHz, ~ 18.58μs                        423.75kHz, ~ 18.88μs

                                                                                     TRANSMITTING A ONE

                                                               ~ 37.46μs

Figure  12.  Uplink  Coding,  Two  Subcarriers Case (High      Data-Rate Timing)

                                                                          423.75kHz                                              423.75kHz

                     ~ 56.64μs                                            ~ 56.64μs                                   ~ 37.76μs

Figure  13.  Uplink  SOF, Single Subcarrier Case (High Data-Rate Timing)

                              484.28kHz                                   423.75kHz                        484.28kHz             423.75kHz

                              ~ 55.75μs                                   ~ 56.64μs                                   ~ 37.46μs

Figure  14.  Uplink  SOF, Two Subcarriers Case (High Data-Rate Timing)

                     _______________________________________________________________________________________                                7
          ISO 15693-Compliant 64-Bit UID

MAX66100     ISO 15693 Slave States and                                ready state and transition to the quiet or the selected

                                           Address Modes               state upon receiving the Stay Quiet or Select command

                                                                       sent in the addressed mode.

          Initially, the master has no information whether there are                                       Quiet State

          any RF devices in the field of its antenna. The master       In this state, a slave has enough power to perform any

          learns the UIDs of the slaves in its field from the          of its functions. The purpose of the quiet state is to

          responses to the Inventory command, which does not           silence slaves that the master does not want to commu-

          use the Address_flag and the Select_flag bits. The state     nicate with. Only commands sent with the addressed

          transitions are controlled by network function com-          mode are accepted and processed. This way the mas-

          mands. Figure 15 shows details.                              ter can use the nonaddressed mode for communication

          ISO 15693 defines four states in which a slave can be        with remaining slaves in the ready state, which mini-

          plus three address modes. The states are power-off,          mizes the size of the request data packets. As long as

          ready, quiet, and selected. The address modes are            no additional slaves arrive in the RF field, it is safe for

          nonaddressed,        addressed,  and  selected.      The     the master to continue communicating in the nonad-

          addressed mode requires that the master include the          dressed mode. A slave can exit the quiet state and

          slave’s UID in the request, which increases the size of      transition to the ready or the selected state upon receiv-

          the requests by 8 bytes. Table 1 shows which address         ing the Reset to Ready or Select command sent in the

          mode is applicable depending on the slave’s state and        addressed mode.

          how to set the Address_flag and the Select_flag bits for

          each address mode.                                                                          Selected State

                        ISO 15693 States and Transitions               In this state, a slave has enough power to perform any

                                                                       of its functions. The purpose of the selected state is to

                                                Power-Off State        isolate the slave that the master wants to communicate

          This state applies if the slave is outside the master’s RF   with. Commands are accepted and processed regard-

          field. A slave transitions to the power-off state when       less of the address mode in which they are sent, includ-

          leaving the power-delivering RF field. When entering         ing the Inventory command. With multiple slaves in the

          the RF field, the slave automatically transitions to the     RF field, the master can put one slave in the selected

          ready state.                                                 state and leave all the others in the ready state. This

                                                Ready State            method requires less communication than using the

          In this state, a slave has enough power to perform any       quiet state to single out the slave for communication.

          of its functions. The purpose of the ready state is to have  For a slave in the selected state, the master can use the

          the slave population ready to process the inventory          selected mode, which keeps the request data packets

          command as well as other commands sent in the                as short as with the nonaddressed mode. A new slave

          addressed or nonaddressed mode. A slave can exit the         entering the RF field cannot disturb the communication,

                                                                       since it stays in the ready state. A slave can exit the

          Table 1. Slave States  and Applicable Address                Modes

                                                                       ADDRESS MODES

                                           NONADDRESSED MODE           ADDRESSED MODE                 SELECTED MODE

             SLAVE STATES                  (Address_flag = 0;          (Address_flag = 1;             (Address_flag = 0;

                                           Select_flag = 0)            Select_flag = 0)               Select_flag = 1)

             Power-Off                          (Inactive)             (Inactive)                     (Inactive)

                        Ready                   Yes                           Yes                     No

                        Quiet                   No                            Yes                     No

             Selected                           Yes                           Yes                     Yes

          8  _______________________________________________________________________________________
                                   ISO 15693-Compliant 64-Bit UID

RESPONSE LEGEND:                                                                                                    ADDRESS MODE LEGEND:     MAX66100

RESPONSE TO RESET TO READY                                    POWER-OFF                                             [N] NONADDRESSED

RESPONSE TO SELECT                                                                                                  [A] ADDRESSED

NO RESPONSE                                                                                                         [S] SELECTED

                                                OUT OF FIELD             IN FIELD

                                                                                       NOTE 1

             OUT OF FIELD                                     READY                                                  OUT  OF  FIELD

                                                                                       RESET TO   READY

                            RESET TO READY [A]                                         [N, A, S]

                                                                         SELECT [A]

                            MATCHING UID                                 MATCHING UID

                                                                                                  SELECT [A],

                                                STAY QUIET [A]                                    NONMATCHING  UID

                                                MATCHING UID

                                                STAY QUIET [A] MATCHING UID

                            QUIET                                                                 SELECTED

                                                SELECT [A] MATCHING UID

                    NOTE 2                                                                                     NOTE  3

NOTE 1: THE SLAVE PROCESSES THE INVENTORY COMMAND AND OTHER COMMANDS PROVIDED THAT THEY ARE SENT IN THE [N] OR [A] ADDRESS MODE.

NOTE 2: THE SLAVE PROCESSES ONLY COMMANDS SENT IN THE [A] ADDRESS MODE.

NOTE 3: THE SLAVE PROCESSES THE INVENTORY COMMAND AND OTHER COMMANDS IN ANY ADDRESS MODE.

Figure 15. ISO 15693 State Transitions Diagram

selected state and transition to the ready or the quiet                  another slave with the matching UID to the selected

state upon receiving the Reset to Ready command sent                     state. If the slave already in the selected state does not

in any address mode or the Stay Quiet command sent                       recognize the command (e.g., due to a bit error), two

in the addressed mode. A slave also transitions from                     slaves could be in the selected state. To prevent this

selected to ready upon receiving a Select command if                     from happening, the master should use the Reset to

the UID in the request is different from the slave’s own                 Ready or the Stay Quiet command to transition a slave

UID. In this case the master’s intention is to transition                out of the selected state.

_______________________________________________________________________________________                                                   9
          ISO 15693-Compliant 64-Bit UID

MAX66100                                                                Request Flags, Inventory_flag Bit Not Set

          BIT 8 (MSb)          BIT 7        BIT 6                BIT 5  BIT 4       BIT 3               BIT 2         BIT 1 (LSb)

              0                Option_flag  Address_flag   Select_flag  0           Inventory_flag  Data_rate_flag  Subcarrier_flag

                                                                                    (= 0)

                                                                               Request Flags, Inventory_flag Bit Set

          BIT 8 (MSb)          BIT 7        BIT 6                BIT 5  BIT 4       BIT 3               BIT 2         BIT 1 (LSb)

              0                0            Nb_slots_flag  AFI_flag     0           Inventory_flag  Data_rate_flag  Subcarrier_flag

                                                                                    (= 1)

                                            Request Flags               Bit 1: Subcarrier Flag (Subcarrier_flag). This bit

          The command descriptions on the subsequent pages              specifies whether the response data packet is transmit-

          begin with a byte called request flags. The ISO 15693         ted using a single subcarrier (bit = 0) or two subcarriers

          standard defines two formats for the request flags byte.      (bit = 1).

          The state of the Inventory_flag bit controls the function                                 Inventory_flag Bit Set

          of the bits in the upper half of the request flags byte.      Bits 8, 7, 4: No Function. These bits have no function.

          The function of the request flags byte is as follows.         They must be transmitted as 0.

                               Inventory_flag Bit Not Set               Bit 6: Slot Counter Flag (Nb_slots_flag). This bit

          Bits 8, 4: No Function. These bits have no function.          specifies whether the command is processed using a

          They must be transmitted as 0.                                slot counter (bit = 0) or without using the slot counter

          Bit 7: Options Flag (Option_flag). This bit is used with      (bit = 1).

          block read commands to include the block security sta-        Bit 5: Application Family Identifier Flag (AFI_flag).

          tus in the response. If not applicable for a command,         To detect only slaves with a certain AFI value, the

          the Option_flag bit must be 0.                                AFI_flag bit must be 1 and the desired AFI value must

          Bit 6: Address Flag (Address_flag). This bit specifies        be included in the request. If the least significant nibble

          whether all slaves in the master’s field that are in the      of the AFI in the request is 0000b, slaves process the

          selected or ready state process the request (bit = 0) or      command only if the most significant nibble of the AFI

          only the single slave whose UID is specified in the           matches. If the AFI in the request is 00h, all slaves

          request (bit = 1). If the Address_flag bit is 0, the          process the command regardless of their AFI.

          request must not include a UID. The combination of            Bit 3: Inventory Flag (Inventory_flag). This bit must

          both the Select_flag and Address_flag bits being set          be 1 for the Inventory command only. For all other com-

          (= 1) is not valid.                                           mands, this bit must be 0.

          Bit 5: Select Flag (Select_flag). This bit specifies          Bit 2: Data Rate Flag (Data_rate_flag). This bit speci-

          whether the request is processed only by the slave in         fies whether the response data packet is transmitted

          the selected state (bit = 1) or by any slave according to     using the low data rate (bit = 0) or the high data rate

          the setting of the Address_flag bit (bit = 0).                (bit = 1).

          Bit 3: Inventory Flag (Inventory_flag). This bit must         Bit 1: Subcarrier Flag (Subcarrier_flag). This bit

          be 1 for the Inventory command only. For all other com-       specifies whether the response data packet is transmit-

          mands, this bit must be 0.                                    ted using a single subcarrier (bit = 0) or two subcarriers

          Bit 2: Data Rate Flag (Data_rate_flag). This bit speci-       (bit = 1).

          fies whether the response data packet is transmitted

          using the low data rate (bit = 0) or the high data rate

          (bit = 1).

          10  ______________________________________________________________________________________
                                            ISO 15693-Compliant 64-Bit UID

                                                                      Request Data for the Inventory Command                                  MAX66100

    REQUEST FLAGS              COMMAND                          AFI              MASK LENGTH                   MASK PATTERN

                                                            (NOTE 1)                                                (NOTE 2)

    (1 Byte)                        01h                     (1 Byte)                    (1 Byte)               (Up to 8 Bytes)

Note 1: The AFI byte is transmitted only if the AFI_flag bit is set to 1. The AFI byte, if transmitted, narrows the range of slaves that

    qualify for responding to the request.

Note 2: The mask pattern is transmitted only if the selection mask length is not 0. If the mask length is not an integer multiple of 8,

    the MSB of the mask pattern must be padded with 0 bits. The LSb of the mask pattern is transmitted first.

                                                    Response Data for the Inventory Command (No Error)

           RESPONSE FLAGS                                   DSFID                                              UID

                   00h                                      (1 Byte)                                    (8 Bytes)

    Network Function Commands                                        cessing of an Inventory command ends when the mas-

The command descriptions show the data fields of the                 ter sends the SOF of a new frame.

request and response data packets. To create the com-                Response data for the Inventory command (no error) is

plete frame, an SOF, 16-bit CRC, and EOF must be                     transmitted only if a slave qualifies to respond. In case

added (see Figure 4). The ISO 15693 standard defines                 of an error in the request, slaves do not respond.

four network function commands: Inventory, Stay Quiet,               When receiving the Inventory command, the slave

Select, and Reset to Ready. This section describes the               devices in the RF field enter the collision management

format of the request and response data packets.                     sequence. If a slave meets the conditions to respond, it

                                                Inventory            sends out a response data packet. If multiple slaves

The Inventory command allows the master to learn the                 qualify, e.g., AFI, mask, and slot counter are not used,

UIDs and DSFIDs of all slaves in its RF field in an itera-           the response frames collide and are not readable. To

tive process. It is the only command for which the                   receive readable response frames with the UID and

Inventory_flag bit must be 1. The Inventory command                  DSFID, the master must eliminate the collision.

uses two command-specific parameters, which are the                  Not knowing the slave population, the master could

mask length and the mask pattern. The mask allows the                begin with a mask length of 0 and activate the slot

master to preselect slaves for responding to the                     counter. By using this method and going through all 16

Inventory command. The LSb of the mask aligns with                   slots, the master has a chance to receive clean

the LSb of the slave’s UID. The master can choose not                responses (i.e., the slave is identified) as well as collid-

to use a mask, in which case all slaves qualify, provid-             ing responses. To prevent a slave that has been identi-

ed they are not excluded by the AFI criteria (see the                fied  from  further  participating        in   the  collision

Request Flags section). The maximum mask length is                   management sequence, the master transitions it to the

60  (3Ch,  if  Nb_slots_flag        =  0)   or  64  (40h,   if       quiet state. Next, the master issues another Inventory

Nb_slots_flag = 1). The mask pattern defines the least               command where the slot number that previously gener-

significant bits (as many as specified by the mask                   ated a collision is now used as a 4-bit mask, and runs

length) that a slave’s UID must match to qualify for                 again through all 16 slots. If a collision is found, another

responding     to     the  Inventory      command       (case        inventory command is issued, this time with a mask that

Nb_slots_flag      =  1).  If  the  slot  counter   is  used         is extended at the higher bits by the slot counter value

(Nb_slots_flag = 0), the value of the slot counter                   that produced the collision. This process is repeated

extends the mask pattern at the higher bits for compari-             until all slaves are identified. For a full description of the

son to the slave’s UID. The slot counter starts at 0 after           Inventory command processing by the slave device

the inventory request frame is transmitted and incre-                and the timing specifications, refer to ISO 15693 Part 3,

ments during the course of the Inventory command with                Sections 8 and 9.

every subsequent EOF sent by the master. The pro-

                   ______________________________________________________________________________________                                 11
          ISO 15693-Compliant 64-Bit UID

MAX66100                                                                     Request Data for the Stay Quiet Command

                     REQUEST FLAGS                                     COMMAND                                         UID

                     (1 Byte)                                           02h                                            (8 Bytes)

                                                                                Request Data for the                   Select     Command*

                     REQUEST FLAGS                                     COMMAND                                         UID

                     (1 Byte)                                           25h                                            (8 Bytes)

          *If this command is processed without any error, the slave  responds with a response flags byte of 00h.

                                                                       Request Data for the Reset to                   Ready      Command*

                     REQUEST FLAGS                                     COMMAND                                         UID**

                     (1 Byte)                                           26h                                            (8 Bytes)

          *If this command is processed without any error, the slave  responds with a response flags byte of 00h.

          **The UID is transmitted only in the addressed mode.

                                                 Stay Quiet                            Memory Function Commands

          The Stay Quiet command addresses an individual slave               The command descriptions show the data fields of the

          and transitions it to the quiet state. The request must be         request and response data packets. To create the com-

          sent in the addressed mode (Select_flag bit = 0,                   plete frame, an SOF, 16-bit CRC, and EOF must be

          Address_flag bit = 1). The slave transitioning to the              added (see Figure 4). ISO 15693 defines three address

          quiet state does not send a response.                              modes, selected, addressed, and nonaddressed,

                                                                Select       which     are  specified  through         the    setting  of  the

          The Select command addresses an individual slave                   Select_flag bit and the Address_flag bit. The memory

          and transitions it to the selected state. The request              function commands can be issued in any address

          must be sent in the addressed mode (Select_flag                    mode.     To   access  slaves         in  the  quiet  state,  the

          bit = 0, Address_flag bit = 1). The slave transitioning to         addressed mode is required. The addressed mode

          the selected state sends a response. If there was a                requires that the master include the slave's UID in the

          slave with a different UID in the selected state, then that        request.

          slave transitions to the ready state without sending a                                                       Error Indication

          response.                                                          In case of an error, the response to a request begins

                                                 Reset to Ready              with a response flags byte 01h followed by one error

          The Reset to Ready command addresses an individual                 code.

          slave and transitions it to the ready state. To address a          If there was no error, the response begins with a

          slave in the quiet state, the request must be sent in the          response flags byte 00h followed by command-specific

          addressed mode (Select_flag bit = 0, Address_flag                  data, as specified in the detailed command description.

          bit = 1). To address a slave in the selected state, the            If the MAX66100 does not recognize a command, it

          request can be sent in any address mode. The slave                 does not generate a response.

          transitioning to the ready state sends a response.

          12  ______________________________________________________________________________________
                                            ISO 15693-Compliant 64-Bit UID

                                                 Request Data for the Get System Information Command                                             MAX66100

         REQUEST FLAGS                                      COMMAND                                               UID

          (1 Byte)                                          2Bh                                                   (8 Bytes)

                               Response Data for the Get System Information Command (No Error)

RESPONSE         INFO              UID          DSFID       AFI            NUMBER OF             MEMORY BLOCK            IC REFERENCE

FLAGS            FLAGS                                                            BLOCKS              SIZE

00h              0Fh           (8 Bytes)    (1 Byte)        (1 Byte)              00h                 07h                          (1 Byte)

Detailed Command Descriptions                                                                                CRC Generation

In the request data graphics of this section, the UID                 The ISO 15693 standard uses a 16-bit CRC, generated

field is shaded to indicate that the inclusion of the UID             according to the CRC-16-CCITT polynomial function:

depends on the address mode.                                          X16 + X12 + X5 + 1 (see Figure 16). This CRC is used

                        Get System Information                        for error detection in request and response data pack-

The Get System Information command is the only com-                   ets and is always communicated in the inverted form.

mand beyond the network function level that the                       After all data bytes are shifted into the CRC generator,

MAX66100 supports. It allows the master to retrieve                   the state of the 16 flip-flops is parallel-copied to a shift

technical information about the MAX66100. The IC ref-                 register and shifted out for transmission with the LSb

erence code indicates the die revision in hexadecimal                 first. For more details on this CRC, refer to ISO/IEC

format, such as A1h, A2h, B1h, etc.                                   15693-3, Annex C.

          MSb                                    POLYNOMIAL = X16 + X12 + X5 + 1

          1ST           2ND          3RD         4TH        5TH                           6TH         7TH         8TH

          STAGE         STAGE        STAGE       STAGE      STAGE                         STAGE       STAGE       STAGE

     X0          X1            X2           X3          X4                        X5             X6          X7

                                                                                                                  LSb

          9TH           10TH         11TH        12TH                      13TH           14TH        15TH        16TH

          STAGE         STAGE        STAGE       STAGE                     STAGE       STAGE          STAGE       STAGE

     X8          X9            X10          X11                       X12         X13            X14         X15              X16

                                                                                                                  INPUT DATA

Figure 16. CRC-16-CCITT Generator

                 ______________________________________________________________________________________                                      13
          ISO 15693-Compliant 64-Bit UID

MAX66100             Command-Specific ISO 15693                         Communication Protocol—Legend

          SYMBOL                      DESCRIPTION                       SYMBOL                         DESCRIPTION

              GSY    Command “Get System Information”                         IFLG   Info Flags byte (always sent by slave)

              SOF    Start of Frame                                           DSFID  Data Storage Format Identifier byte

              RQF    Request Flags byte (always sent by master)               AFI    Application Family Identifier byte

          CRC-16     Transmission of an inverted CRC-16 (2 bytes)             NBLK   Number of Blocks byte (slave memory size

                     generated according to CRC-16-CCITT                             indicator)

              EOF    End of Frame                                             MBS    Memory Block Size byte (slave memory block

              RSF    Response Flags byte (always sent by slave)                      s i ze)

                     The tag’s unique 8-byte identification number;           ICR    IC Reference byte (slave chip revision)

              [UID]  could be sent by either the master or the slave.

                     The brackets [ ] indicate that the transmission

                     of the UID depends on the request flags (RQF).

              Command-Specific ISO 15693 Communication Protocol—Color Codes

                                                       Master-to-Slave  Slave-to-Master

                                                                        ISO 15693 Communication Examples

              Get System Information

              SOF    RQF  GSY  [UID]  CRC-16  EOF                                    (Carrier)

                                      Success          SOF  RSF = 00h   IFLG  UID    DSFID  AFI  NBLK  MBS  ICR  CRC-16      EOF

          14  ______________________________________________________________________________________
           ISO      15693-Compliant 64-Bit UID

                                              Mechanical Drawings                           MAX66100

TOP VIEW

                    54mm

28mm                                   7.7mm

                    MAX66100K-000AA+

                                       1.6mm

SIDE VIEW

                    KEY FOB

TOP VIEW

                    85.60mm

           3.49mm

           14.29mm            53.98mm          MAX66100E-000AA+

SIDE VIEW                              0.76mm

                    ISO CARD

______________________________________________________________________________________  15
          ISO 15693-Compliant                  64-Bit       UID

MAX66100                                                                                                            Revision History

          REVISION  REVISION                   DESCRIPTION                                                          PAGES

          NUMBER    DATE                                                                                            CHANGED

              0     1/11      Initial release                                                                       —

          Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are

          implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.

          16  ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA                   94086 408-737-7600

          ©   2011 Maxim Integrated Products   Maxim is a registered trademark of Maxim Integrated Products, Inc.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery  &  Lifecycle  Information:

Maxim Integrated:

MAX66100E-000AA+   MAX66100K-000AA+

小广播

MAX66100K-000AA-器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved