19-2535; Rev 1; 12/05

Low-Power, Single-/Dual-Level Battery Monitors

                       with Hysteresis and Integrated µP Reset

                       General Description                                                                    Features             MAX6439–MAX6442

The MAX6439–MAX6442 are a family of ultra-low-power         ♦  Factory-Trimmed VBATT Threshold Options for

battery monitors with integrated microprocessor (µP)           Monitoring Single-Cell Li+ or Multicell

supervisors. The battery monitors are offered with sin-        Alkaline/NiCd/NiMH Applications

gle or dual low-battery output options that can be used

to signal when the battery is OK (enabling full system      ♦  Immune to Short Battery Voltage Transients

operation), when the battery is low (for low-power sys-     ♦  Low Current (2.5µA typ at 3.6V)

tem operation), and when the battery is dead (to dis-

able system operation). These devices also have an          ♦  Single and Dual Low-Battery Output Options

independent µP supervisor that monitors VCC and pro-        ♦  150ms Minimum LBO Timeout Period

vides an active-low reset output. A manual reset func-

tion is available to reset the µP with a push-button. No    ♦  Independent µP Reset with Manual Reset

external components are required.                           ♦  Factory-Set Reset Thresholds for Monitoring VCC

The MAX6439–MAX6442 are offered with several facto-            from 1.8V to 3.3V

ry-trimmed low-battery threshold combinations ideal for     ♦  Available with 150ms (min) and 1.2s (min) VCC

single-cell lithium-ion (Li+) or multicell alkaline/NiCd/

NiMH applications. When the battery voltage drops              Reset Timeout Period Options

below each specified low threshold, the low-battery out-    ♦  -40°C to +85°C Operating Temperature Range

puts are asserted to alert the system. When the voltage

rises above the specified high thresholds, the outputs      ♦  Small 6- and 8-Pin SOT23 Packages

are deasserted after a 150ms minimum timeout period,        ♦  No External Components

ensuring the voltages have stabilized before power cir-                              Ordering Information

cuitry is activated or providing microprocessor reset tim-

ing. The low and high thresholds provide hysteresis in

battery-operated systems to eliminate output chattering.       PART                  TEMP RANGE               PIN-PACKAGE

The MAX6439/MAX6440 offer factory-trimmed battery           MAX6439UT_ _ _D_-T       -40°C to +85°C           6 SOT23-6

monitors with a single output. The MAX6441/MAX6442          MAX6440UT_ _ _D_-T       -40°C to +85°C           6 SOT23-6

offer factory-trimmed battery monitors with dual outputs.   MAX6441KA_ _ _D_-T       -40°C to +85°C           8 SOT23-8

All battery monitors have open-drain low-battery outputs.   MAX6442KA_ _ _D_-T       -40°C to +85°C           8 SOT23-8

The MAX6439–MAX6442 monitor system voltages                 Note: The first two “_ _” are placeholders for the battery moni-

(VCC) from 1.8V to 3.3V with seven fixed reset threshold    tor voltage levels. Desired threshold levels are set by the part

options. Each device is offered with two minimum reset      number suffix found in Tables 1 and 2. The third “_” is the VCC

timeout periods of 150ms or 1200ms. The MAX6439/            reset threshold level suffix found in Table 3. The “_” after the D

MAX6441 are offered with an open-drain RESET output         is a placeholder for the reset timeout period suffix found in

and the MAX6440/MAX6442 are offered with a push-            Table 4. All devices are available in tape-and-reel only. There

pull RESET output.                                          is a 2500-piece minimum order increment for standard ver-

                                                            sions. Sample stock is typically held on standard versions only.

The MAX6439–MAX6442 are offered in a SOT23 pack-            Nonstandard versions require a minimum order increment of

age and are fully specified over a -40°C to +85°C temp-     10,000 pieces. Contact factory for availability.

erature range.                                              Devices are available in both leaded and lead-free packaging.

                                                            Specify lead-free by replacing “-T” with “+T” when ordering.

                                   Applications                                      Pin Configurations

Battery-Powered Systems (Single-Cell Li+ or                    TOP VIEW

Two-/Three-Cell NiMH, NiCd, Alkaline)

Cell Phones/Cordless Phones                                              VBATT    1             6    VCC

Portable Medical Devices                                                 MR       2  MAX6439    5    GND

Electronic Toys                                                                      MAX6440

Pagers                                                                   LBO      3             4    RESET

PDAs

MP3 Players                                                                          SOT23-6

                                                            Pin Configurations continued at end of data sheet.

                       ________________________________________________________________ Maxim Integrated Products               1

For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at

1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442  ABSOLUTE MAXIMUM RATINGS

                 VBATT, VCC to GND.................................................-0.3V to +6V*   Operating Temperature Range .......................... -40°C to +85°C

                 Open-Drain LBO, LBOH, LBOL, LBOLH to GND ...-0.3V to +6V*                         Junction Temperature ......................................................+150°C

                 Open-Drain RESET to GND ....................................-0.3V to +6V*         Storage Temperature Range .............................-65°C to +150°C

                 Push-Pull RESET to GND............................-0.3V to (VCC + 0.3V)           Lead Temperature (soldering, 10s) .................................+300°C

                 MR to GND .................................................-0.3V to (VCC + 0.3V)

                 Input/Output Current, All Pins .............................................20mA

                 Continuous Power Dissipation (TA = +70°C)

                    6-Pin SOT23 (derate 8.7mW/°C above +70°C)............695mW

                    8-Pin SOT23 (derate 8.9mW/°C above +70°C)............714mW

                 *Applying 7V for a duration of 1ms does not damage the device.

                 Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional

                 operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to

                 absolute maximum rating conditions for extended periods may affect device reliability.

                 ELECTRICAL CHARACTERISTICS

                 (VBATT = 1.2V to 5.5V, VCC = 1.2V to 5.5V, TA = -40°C to +85°C, unless otherwise specified.          Typical values  are at  TA  = +25°C.) (Note1)

                    PARAMETER                   SYMBOL                                             CONDITIONS             MIN         TYP         MAX    UNITS

                 VBATT Operating Voltage Range  VBATT        TA = 0°C to +85°C                                            1.0                     5.5                           V

                                                             TA = -40°C to +85°C                                          1.2                     5.5

                 VCC Operating Voltage Range    VCC          TA = 0°C to +85°C                                            1.0                     5.5                           V

                                                             TA = -40°C to +85°C                                          1.2                     5.5

                 VCC + VBATT Supply Current     ICC + IBATT  VBATT = 3.6V, VCC = 3.3V, no load                 (Note  2)              2.5         7                             µA

                 VBATT THRESHOLDS

                                                             MAX6439UT_ J, MAX6440UT_ J                                   3.510       3.60        3.690

                                                             MAX6439UT_ I, MAX6440UT_ I                                   3.413       3.50        3.588

                                                             MAX6439UT_ H, MAX6440UT_ H                                   3.315       3.40        3.485

                 HTH Threshold                  HTH          MAX6439UT_ G, MAX6440UT_ G                                   3.218       3.30        3.383                         V

                                                             MAX6439UT_ T, MAX6440UT_ T                                   2.535       2.60        2.665

                                                             MAX6439UT_ S, MAX6440UT_ S                                   2.438       2.50        2.563

                                                             MAX6439UT_ R, MAX6440UT_ R                                   2.340       2.40        2.460

                                                             MAX6439UT_ Q, MAX6440UT_ Q                                   2.243       2.30        2.358

                                                             MAX6439UTF, MAX6440UTF                                       3.023       3.10        3.178

                                                             MAX6439UTE, MAX6440UTE                                       2.925       3.00        3.075

                                                             MAX6439UTD, MAX6440UTD                                       2.828       2.90        2.973

                                                             MAX6439UTC, MAX6440UTC                                       2.730       2.80        2.870

                                                             MAX6439UTB, MAX6440UTB                                       2.633       2.70        2.768

                 LTH Threshold                  LTH          MAX6439UTA, MAX6440UTA                                       2.535       2.60        2.665                         V

                                                             MAX6439UTP, MAX6440UTP                                       2.048       2.10        2.153

                                                             MAX6439UTO, MAX6440UTO                                       1.950       2.00        2.050

                                                             MAX6439UTN, MAX6440UTN                                       1.853       1.90        1.948

                                                             MAX6439UTM, MAX6440UTM                                       1.755       1.80        1.845

                                                             MAX6439UTL, MAX6440UTL                                       1.658       1.70        1.743

                                                             MAX6439UTK, MAX6440UTK                                       1.560       1.60        1.640

                 2  _______________________________________________________________________________________
Low-Power, Single-/Dual-Level Battery Monitors

                with Hysteresis and Integrated µP Reset

ELECTRICAL CHARACTERISTICS (continued)                                                                                                     MAX6439–MAX6442

(VBATT = 1.2V to 5.5V, VCC = 1.2V to 5.5V, TA = -40°C to +85°C, unless otherwise specified.  Typical values  are at TA  = +25°C.) (Note1)

PARAMETER       SYMBOL  CONDITIONS                                                           MIN             TYP        MAX    UNITS

                        MAX6441UT_ J, MAX6442UT_ J                                           3.510           3.600      3.690

                        MAX6441UT_ I, MAX6442UT_ I                                           3.413           3.500      3.588

                        MAX6441UT_ H, MAX6442UT_ H                                           3.315           3.400      3.485

HTH- Threshold  HTH-    MAX6441UT_ G, MAX6442UT_ G                                           3.218           3.300      3.383  V

                        MAX6441UT_ T, MAX6442UT_ T                                           2.535           2.600      2.665

                        MAX6441UT_ S, MAX6442UT_ S                                           2.438           2.500      2.563

                        MAX6441UT_ R, MAX6442UT_ R                                           2.340           2.400      2.460

                        MAX6441UT_ Q, MAX6442UT_ Q                                           2.243           2.300      2.358

                        MAX6441UT_ J, MAX6442UT_ J                                           3.686           3.780      3.875

                        MAX6441UT_ I, MAX6442UT_ I                                           3.583           3.675      3.767

                        MAX6441UT_ H, MAX6442UT_ H                                           3.481           3.570      3.659

HTH+ Threshold  HTH+    MAX6441UT_ G, MAX6442UT_ G                                           3.378           3.465      3.552  V

                        MAX6441UT_ T, MAX6442UT_ T                                           2.662           2.730      2.798

                        MAX6441UT_ S, MAX6442UT_ S                                           2.559           2.625      2.691

                        MAX6441UT_ R, MAX6442UT_ R                                           2.457           2.520      2.583

                        MAX6441UT_ Q, MAX6442UT_ Q                                           2.355           2.415      2.476

                        MAX6441UTF, MAX6442UTF                                               3.023           3.100      3.178

                        MAX6441UTE, MAX6442UTE                                               2.925           3.000      3.075

                        MAX6441UTD, MAX6442UTD                                               2.828           2.900      2.973

                        MAX6441UTC, MAX6442UTC                                               2.730           2.800      2.870

                        MAX6441UTB, MAX6442UTB                                               2.633           2.700      2.768

LTH- Threshold  LTH-    MAX6441UTA, MAX6442UTA                                               2.535           2.600      2.665  V

                        MAX6441UTP, MAX6442UTP                                               2.048           2.100      2.153

                        MAX6441UTO, MAX6442UTO                                               1.950           2.000      2.050

                        MAX6441UTN, MAX6442UTN                                               1.853           1.900      1.948

                        MAX6441UTM, MAX6442UTM                                               1.755           1.800      1.845

                        MAX6441UTL, MAX6442UTL                                               1.658           1.700      1.743

                        MAX6441UTK, MAX6442UTK                                               1.560           1.600      1.640

                        MAX6441UTF, MAX6442UTF                                               3.174           3.255      3.337

                        MAX6441UTE, MAX6442UTE                                               3.071           3.150      3.229

                        MAX6441UTD, MAX6442UTD                                               2.969           3.045      3.121

                        MAX6441UTC, MAX6442UTC                                               2.867           2.940      3.014

                        MAX6441UTB, MAX6442UTB                                               2.764           2.835      2.906

LTH+ Threshold  LTH+    MAX6441UTA, MAX6442UTA                                               2.662           2.730      2.798  V

                        MAX6441UTP, MAX6442UTP                                               2.150           2.205      2.260

                        MAX6441UTO, MAX6442UTO                                               2.048           2.100      2.153

                        MAX6441UTN, MAX6442UTN                                               1.945           1.995      2.045

                        MAX6441UTM, MAX6442UTM                                               1.843           1.890      1.937

                        MAX6441UTL, MAX6442UTL                                               1.740           1.785      1.830

                        MAX6441UTK, MAX6442UTK                                               1.638           1.680      1.722

                _______________________________________________________________________________________                               3
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442  ELECTRICAL CHARACTERISTICS (continued)

                 (VBATT = 1.2V to 5.5V, VCC = 1.2V to 5.5V, TA = -40°C to +85°C, unless otherwise specified. Typical values are at TA = +25°C.) (Note1)

                          PARAMETER           SYMBOL                CONDITIONS                        MIN        TYP    MAX        UNITS

                 LBO, LBOL, LBOH, LBOLH       tLBOP   VBATT rising above threshold                    150        225    300                              ms

                 Timeout Period

                 LBO, LBOL, LBOH, LBOLH       tLBOD   VBATT falling below threshold                              100                                     µs

                 Delay Time

                                                      (VBATT or VCC) ≥ 1.2V, ISINK = 50µA,                              0.3

                                                      asserted low

                 LBO, LBOL, LBOH, LBOLH               (VBATT or VCC) ≥ 1.6V, ISINK = 100µA,                             0.3

                                                      asserted low

                 Output Low                   VOL                                                                                                        V

                 (Open Drain)                         (VBATT or VCC) ≥ 2.7V, ISINK = 1.2mA,                             0.3

                                                      asserted low

                                                      (VBATT or VCC) ≥ 4.5V, ISINK = 3.2mA,                             0.3

                                                      asserted low

                 LBO, LBOL, LBOH, LBOLH

                 Output Open-Drain Leakage    ILKG    Output deasserted                                                 500                              nA

                 Current

                                                      MAX64_ _ _ _ _ _ T                              3.000      3.075  3.150

                                                      MAX64_ _ _ _ _ _ S                              2.850      2.925  3.000

                                                      MAX64_ _ _ _ _ _ R                              2.550      2.625  2.700

                 VCC Reset Threshold          VTH     MAX64_ _ _ _ _ _ Z                              2.250      2.313  2.375                            V

                                                      MAX64_ _ _ _ _ _ Y                              2.125      2.188  2.250

                                                      MAX64_ _ _ _ _ _ W                              1.620      1.665  1.710

                                                      MAX64_ _ _ _ _ _ V                              1.530      1.575  1.620

                 VCC Reset Hysteresis                                                                            0.3                                     %

                 VCC to RESET Delay                   VCC falling at 10mV/µs  from   (VTH  +  100mV)             50                                      µs

                                                      to (VTH - 100mV)

                 VCC to RESET Timeout Period  tRP     MAX64_ _ _ _ _ _ _ D3                           150        225    300                              ms

                                                      MAX64_ _ _ _ _ _ _ D7                           1200       1800   2400

                 MR Input Voltage             VIL                                                                       0.3 x VCC                        V

                                              VIH                                                     0.7 x VCC

                 MR Minimum Pulse Width       tMPW                                                    1                                                  µs

                 MR Glitch Rejection                                                                             100                                     ns

                 MR to RESET Delay                                                                               200                                     ns

                 MR Reset Timeout Period      tMRP                                                    150        225    300                              ms

                 MR Pullup Resistance                 MR to VCC                                       750        1500   2250                             Ω

                 MR Rising Debounce Period    tDEB    (Note 3)                                        150        225    300                              ms

                 4  _______________________________________________________________________________________
Low-Power, Single-/Dual-Level Battery Monitors

                                       with Hysteresis and Integrated µP Reset

ELECTRICAL CHARACTERISTICS (continued)                                                                                                                                                                                                                                  MAX6439–MAX6442

(VBATT = 1.2V to 5.5V, VCC = 1.2V to 5.5V, TA = -40°C to +85°C, unless otherwise specified. Typical values                                                                                                                     are at  TA  = +25°C.) (Note1)

                             PARAMETER                       SYMBOL                                                               CONDITIONS                                                                        MIN        TYP         MAX       UNITS

                                                                                                               VCC ≥ 1.53V, ISOURCE = 100µA, RESET                                                                  0.8 x VCC

RESET Output High                                                                                              deasserted

(Push-Pull)                                                      VOH                                           VCC ≥ 2.55V, ISOURCE = 500µA, RESET                                                                                                   V

                                                                                                               deasserted                                                                                           0.8 x VCC

                                                                                                               VCC ≥ 1.0V, ISINK = 50µA, RESET asserted                                                                                    0.3

RESET Output Low                                                 VOL                                           VCC ≥ 1.2V, ISINK = 100µA, RESET asserted                                                                                   0.3       V

                                                                                                               VCC ≥ 2.12V, ISINK = 1.2mA, RESET                                                                                           0.3

                                                                                                               asserted

RESET Output Leakage Current                                                                                   RESET deasserted                                                                                                            500       nA

(Open Drain)

Note 1: Production testing done at TA = +25°C; limits over temperature guaranteed by design only.

Note 2: The device is powered up by the highest voltage between VBATT and VCC.

Note 3: MR input ignores falling input pulses, which occur within the MR debounce period (tDEB) after a valid MR reset assertion.

                             This prevents invalid reset assertion due to switch bounce.

                                                                                                                                      Typical Operating Characteristics

(VBATT = 1.2V to 5.5V, VCC = 1.2V to 5.5V,                                      unless otherwise specified. Typical values are at TA = +25°C.)

                        SUPPLY CURRENT vs. TEMPERATURE                                                                    NORMALIZED LBO TIMEOUT PERIOD                                                             NORMALIZED RESET TIMEOUT PERIOD

                             VCC = 3.3V, VBATT = 3.6V                                                                          vs. TEMPERATURE                                                                                 vs. TEMPERATURE

                     4                                           MAX6439 toc01                                 1.10                                          MAX6439 toc02                                   1.015                                       MAX6439 toc03

                                                                                NORMALIZED LBO TIMEOUT PERIOD                                                               NORMALIZED RESET TIMEOUT PERIOD  1.010

SUPPLY CURRENT (µA)  3                                                                                         1.05                                                                                          1.005

                             TOTAL

                                                                                                                                                                                                             1.000

                     2                                                                                         1.00

                                                                                                                                                                                                             0.995

                                               IBATT

                     1                                                                                         0.95                                                                                          0.990

                                                    ICC

                                                                                                                                                                                                             0.985

                     0                                                                                         0.90                                                                                          0.980

                        -40  -20    0  20  40            60  80                                                      -40  -20  0  20  40         60      80                                                         -40  -20   0       20  40    60  80

                                  TEMPERATURE (°C)                                                                             TEMPERATURE (°C)                                                                                TEMPERATURE (°C)

                                       _______________________________________________________________________________________                                                                                                                              5
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442                                                                                                                                                                   Typical Operating Characteristics (continued)

                 (VBATT = 1.2V to 5.5V, VCC = 1.2V to 5.5V, unless otherwise specified. Typical values are at TA = +25°C.)

                                                             MAXIMUM VBATT TRANSIENT DURATION                                                                                         MAXIMUM VCC TRANSIENT DURATION                                                                      NORMALIZED UPPER (HTH) AND LOWER

                                                                 vs. LTH THRESHOLD OVERDRIVE                                                                                                  vs. VTH THRESHOLD OVERDRIVE                                                                 (LTH) TRIP VOLTAGES vs. TEMPERATURE

                 MAXIMUM VBATT TRANSIENT DURATION (µs)  120                                                                MAX6439 toc04                                          60                                                                         toc05                1.050                                                              toc06

                                                        110                                                                                  MAXIMUM VCC TRANSIENT DURATION (µs)  55                                                                         MAX6439                                                                                 MAX6439

                                                                 LBO ASSERTS ABOVE                                                                                                50                         RESET ASSERTS ABOVE                                      VOLTAGES    1.025

                                                        100                                  THIS LINE                                                                            45                         THIS LINE

                                                                                                                                                                                                                                                                      TRIP                        LOWER TRIP VOLTAGE

                                                        90                                                                                                                        40                                                                                  NORMALIZED  1.000

                                                                                                                                                                                  35                                                                                                              UPPER TRIP VOLTAGE

                                                        80

                                                                                                                                                                                  30                                                                                              0.975

                                                        70                                                                                                                        25

                                                        60                                                                                                                        20                                                                                              0.950

                                                             10                                     100                1000                                                           10                     100                                          1000                            -40     -20      0    20       40                  60  80

                                                                 LTH THRESHOLD OVERDRIVE (mV)                                                                                                                VTH THRESHOLD OVERDRIVE (mV)                                                                  TEMPERATURE (°C)

                                                                                                         NORMALIZED RESET THRESHOLD                                                                                                                                   LBO OUTPUT vs. SINK CURRENT

                                                                                                                 vs. TEMPERATURE                                                                                                                                           VCC = 3.3V, VBATT = 2.1V

                                                                                             1.050                                                                                            MAX6439 toc07                                         120                                                                       MAX6439 toc08

                                                                 NORMALIZED RESET THRESHOLD                                                                                                                                                         100

                                                                                             1.025

                                                                                                                                                                                                                                  LBO OUTPUT (mV)   80

                                                                                             1.000                                                                                                                                                  60

                                                                                                                                                                                                                                                    40

                                                                                             0.975

                                                                                                                                                                                                                                                    20

                                                                                                                                                                                                                                                                                                           LBO ASSERTED

                                                                                             0.950                                                                                                                                                  0

                                                                                                    -40  -20     0     20                 40                                      60      80                                                              0                       2            4       6        8        10

                                                                                                                 TEMPERATURE (°C)                                                                                                                                                              ISINK (mA)

                                                                                                         RESET OUTPUT vs. SINK CURRENT                                                                                                                       RESET OUTPUT vs. SOURCE CURRENT

                                                                                                         VCC = 2.1V, VBATT = 3.6V                                                                                                                                     VCC = 3.3V, VBATT = 3.6V

                                                                                             140                                                                                              toc09                                                 3.50                                                                 toc10

                                                                                             120                                                                                              MAX6439                                                                                                                    MAX6439

                                                                 RESET OUTPUT (mV)           100                                                                                                                                                    3.25

                                                                                             80                                                                                                                                   RESET OUTPUT (V)

                                                                                                                                                                                                                                                    3.00

                                                                                             60

                                                                                             40                                                                                                                                                     2.75

                                                                                                                                             RESET ASSERTED

                                                                                             20

                                                                                             0                                                                                                                                                      2.50

                                                                                                    0         2     4                     6                                       8           10                                                          0           0.5            1.0  1.5     2.0      2.5  3.0      3.5

                                                                                                                    ISINK (mA)                                                                                                                                                            ISOURCE (mA)

                 6                                      _______________________________________________________________________________________
Low-Power, Single-/Dual-Level Battery Monitors

               with Hysteresis and Integrated µP Reset

                                                                                             Pin Description                         MAX6439–MAX6442

          PIN

MAX6439/  MAX6441/      NAME                                                 FUNCTION

MAX6440        MAX6442

1              1        VBATT        Battery Voltage Input. Input for battery voltage threshold monitors and device power supply

                                     if VBATT is greater than VCC.

                                     Manual Reset Input, Active-Low, Internal 1.5kΩ Pullup to VCC. Pull low to assert a one-shot

2              3        MR           edge-triggered RESET output for the MR reset timeout period. Leave unconnected or

                                     connect to VCC if unused. The MR input is debounced for MR rising edges to prevent false

                                     reset events.

                                     Low-Battery Output, Active Low, Open Drain. LBO is asserted when VBATT drops below the

3              —        LBO          LTH specification and remains asserted until VBATT rises above the HTH specification for at

                                     least 150ms.

                                     Reset Output, Active Low, Push-Pull or Open Drain. RESET changes from high to low when

                                     the VCC input drops below the selected reset threshold and remains low for the VCC reset

                                     timeout period after VCC exceeds the reset threshold. RESET is one-shot edge-trigger

4              5        RESET        pulsed low for the MR reset timeout period when the MR input is pulled low. RESET is an

                                     open-drain output for the MAX6439/MAX6441, and a push-pull output for the

                                     MAX6440/MAX6442. The push-pull outputs are referenced to VCC. RESET is guaranteed to

                                     be in the correct logic state for VBATT or VCC > 1.0V.

5              2        GND          Ground

6              8        VCC          VCC Voltage Input. Input for VCC reset threshold monitor and device power supply if VCC is

                                     greater than VBATT.

                                     Low-Battery Output High, Active Low, Open Drain. LBOH is asserted when VBATT drops

—              6        LBOH         below the HTH- specification. LBOH is deasserted when VBATT rises above the HTH+

                                     specification for at least 150ms.

                                     Low-Battery Output Low, Active Low, Open Drain. LBOL is asserted when VBATT drops

—              7        LBOL         below the LTH- specification. LBOL is deasserted when VBATT rises above the LTH+

                                     specification for at least 150ms.

                                     Low-Battery Output Low/High, Active Low, Open Drain. LBOLH is asserted when VBATT

—              4        LBOLH        drops below the LTH- specification. LBOLH is deasserted when VBATT rises above the

                                     HTH+ specification for at least 150ms.

                        Detailed Description                        monitor separate high-voltage and low-voltage thresh-

The MAX6439–MAX6442 family is available with several                olds to determine battery status. The output(s) can be

monitoring options. The factory-trimmed thresholds                  used to signal when the battery is charged, when the

eliminate the requirement for external components. The              battery is low, and when the battery is empty. Factory-

MAX6439/MAX6440 have single low-battery outputs                     trimmed thresholds are ideal for monitoring single-cell

and the MAX6441/MAX6442 have dual low-battery out-                  Li+ or multicell alkaline/NiCd/NiMH power supplies.

puts (see Figure 1a and Figure 1b).                                 When the power-supply voltage drops below the speci-

The MAX6439–MAX6442 combine a 1.23V reference                       fied low threshold, the low-battery output asserts. When

with two comparators, logic, and timing circuitry to pro-           the voltage rises above the specified high threshold fol-

vide the user with information about the charge state of            lowing a 150ms (min) timeout period, the low-battery

the power-supply batteries. The MAX6441/MAX6442                     output is deasserted. This ensures the supply voltage

               _______________________________________________________________________________________                            7
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442                                                                   VBATT

                    VBATT                                                                                        MAX6441

                                                             MAX6440                            LTH

                                                                                                DETECT                                LBOL

                                                                                         5%

                                   LTH                                                   HYST

                           DETECT

                                                                                                                     LBO

                                                             R  Q                                                TIMEOUT

                                                                                                                 PERIOD

                                                             S  Q                                                                     LBOH

                                                                           LBO

                                   HTH          LBO TIMEOUT                                     HTH

                           DETECT               PERIOD                                          DETECT

                                                                                         5%

                                                                                         HYST

                                                                                                                                      LBOLH

                    VCC            1.23V

                                                                      VCC

                                                                                  VCC    1.23V

                                   VTH          RESET

                           DETECT               TIMEOUT                    RESET                                                      RESET

                                                PERIOD                                                           RESET

                                                                                                VTH              TIMEOUT

                                                                                                DETECT           PERIOD

                                                                VCC

                                                MR                                                                         VCC

                                                                                                                 MR

                 Figure 1a. Functional Diagram                                    Figure 1b. Functional Diagram

                 has stabilized before power-converter or microproces-            low-battery outputs: LBOH, LBOL, and LBOLH. LBOH

                 sor activity is enabled.                                         asserts when VBATT drops below VHTH- and remains

                 These devices also have an independent µP supervisor             asserted for at least 150ms after VBATT rises above
                                                                                  VHTH+. LBOL asserts when VBATT drops below VLTH-
                 that monitors VCC and provides an active-low reset out-
                                                                                  and remains asserted for at least 150ms after VBATT
                 put. A manual reset function is available to allow the           rises above VLTH+. LBOLH asserts when VBATT drops

                 user to reset the µP with a push-button.                         below VLTH- and remains asserted for at least 150ms

                                                Low-Battery Output                after VBATT rises above VHTH+ (see Figure 3). For fast-

                 The low-battery outputs are available in active-low              rising VBATT input, the LBOL timeout period must com-

                 (LBO, LBOL, LBOH, LBOLH), open-drain configura-                  plete before the LBOH/LBOLH timeout period begins.

                 tions. The low-battery outputs can be pulled to a volt-                                                   Reset Output

                 age independent of VCC or VBATT, up to 5.5V. This                The MAX6439–MAX6442 provide an active-low reset

                 allows the device to monitor and operate from direct             output (RESET). RESET is asserted when the voltage at

                 battery voltage while interfacing to higher voltage              VCC falls below the reset threshold level. Reset remains

                 microprocessors.                                                 asserted for the reset timeout period after VCC exceeds

                 The MAX6439/MAX6440 single-output voltage monitors               the threshold. If VCC goes below the reset threshold

                 provide a single low-battery output, LBO. These fixed-           before the reset timeout period is completed, the inter-

                 threshold devices assert LBO when VBATT drops below              nal timer restarts. The MAX6439/MAX6441 have open-

                 VLTH and remain asserted for at least 150ms after                drain reset outputs, while the MAX6440/MAX6442 have

                 VBATT rises above VHTH (see Figure 2). The MAX6441/              push-pull reset outputs (see Figure 4).

                 MAX6442 triple-output voltage monitors provide three

                 8  _______________________________________________________________________________________
Low-Power, Single-/Dual-Level Battery Monitors

                    with Hysteresis and Integrated µP Reset

                                       VBATT                                                                         MAX6439–MAX6442

                    HTH

                    LTH

                         LBO                       tLBOP              tLBOD                               tLBOP

Figure  2.  Single  Low-Battery  Output Timing

                    HTH+               VBATT

                    HTH-

                    LTH+

                    LTH-

                         LBOL          tLBOP                          tD                    tLBOP

                         LBOH                      tLBOP          tD                                      tLBOP

                         LBOLH

Figure  3.  Dual Low-Battery Output Timing

                         VCC

                                       VTH

                         GND

                                                          SWITCH      SWITCH        SWITCH  SWITCH

                                                          BOUNCE      BOUNCE        BOUNCE  BOUNCE

                         MR

                         GND

                    RESET                     tRP         tMRP                      tMRP

                         GND                                                  tDEB                  tDEB

                                                          tMPW                      tMPW

Figure  4.  RESET   Timing    Diagram

                         _______________________________________________________________________________________  9
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442                                                                              CURRENT-

                      VHTH                                                                   LIMITED                                          DC/DC CONVERTER

                                                                                             AC WALL                                          IN               SHDN

                                                                                             ADAPTER

                 VBATT                               VHYST                                             LED                                            OUT

                        VLTH                                                                                       IN     GATE

                                                                                                            CHG           BATT                VBATT   VCC      LBOL

                                                                                                                                     1-CELL

                                              tLBOP                                                                    MAX1879       Li+              MAX6441

                                                                                             PULSE-WIDTH                             BATTERY          MAX6442

                                                                                             SELECT INPUT   TSEL                GND                            LBOH

                 LBO

                                                                                                                   THERM  ADJ                              LBOLH

                        HTH = BATTERY VOLTAGE GOOD, ENABLE OPERATION.                                                                                      RESET

                        LTH = BATTERY VOLTAGE LOW, SUSPEND/DISABLE OPERATION.                          THERMISTOR                                     GND

                 Figure 5. Hysteresis                                                        Figure 6. Li+ Charger Application       (Using MAX1879)

                                                                                             logic levels, open-drain/open-collector outputs, or a

                                                                                             momentary push-button switch to GND (the MR function

                                       IN     DC/DC    OUT                                   is internally debounced for the tDEB timeout period) to

                        Li+                   SHDN                                           create a manual reset function. If MR is driven from long

                     3.6V                                                                    cables, or if the device is used in a noisy environment,

                                                                                             connect a 0.1µF capacitor from MR to GND to provide

                                              LBOL     VCC                          VCC      additional noise immunity (see Figure 4).

                                       VBATT           LBOH                    NMI                                                            Hysteresis

                                              MAX6441                                        Hysteresis increases the comparator’s noise margin by

                                              MAX6442                                 µP     increasing the upper threshold or decreasing the lower

                                       MR                                                    threshold. The hysteresis prevents the output from

                                                                                             oscillating (chattering) when VBATT is near the low-bat-

                                                       RESET                   RESET         tery threshold. This is especially important for applica-

                                              GND                                   GND      tions where the load on the battery creates significant

                                                                                             fluctuations in battery voltages (see Figure 5).

                                                                                                                   Applications Information

                 Figure 7. DC-to-DC Converter Application                                                   Li+ Battery Charger Application

                                                                                             The MAX6441/MAX6442 dual-output battery monitors

                                                                                             can be used in conjunction with a battery charger to

                                                                               Manual Reset  provide a system with additional information about the

                 Many microprocessor-based products require manual                           battery charge state. Many battery chargers, such as

                 reset capability, allowing the operator, a test technician,                 the MAX1879, provide the user with a CHG output,

                 or external logic circuitry to initiate a reset while the                   which tells the system when the battery is charged. The

                 monitored supplies remain above their reset thresholds.                     MAX6441/MAX6442 dual-output battery monitors pro-

                 These devices have a dedicated active-low MR pin.                           vide three outputs, which can be used to relay the bat-

                 When MR is pulled low, RESET asserts a one-shot low                         tery condition to the system. This information is useful in

                 pulse for the MR reset timeout period. The MR input has                     determining which system resources can be powered by

                 an internal 1.5kΩ pullup resistor to VCC and can be left                    the battery at the current charge state (see Figure 6).

                 unconnected if not used. MR can be driven with CMOS-

                 10     ______________________________________________________________________________________
Low-Power, Single-/Dual-Level Battery Monitors

            with Hysteresis and Integrated µP Reset

Table 1. Factory-Trimmed Lower and Upper Threshold Combinations                               for  Single-Cell  Li+       MAX6439–MAX6442

or Three-Cell Alkaline/NiCd/NiMH Applications

            VOLTAGES                                       UPPER THRESHOLD (HTH)

                        3.3V                               3.4V                   3.5V                  3.6V

                  2.6V           AG                        AH                     AI                    AJ

LOWER             2.7V           BG                        BH                     BI                    BJ

THRESHOLD         2.8V           CG                        CH                     CI                    CJ

(LTH)

                  2.9V           DG                        DH                     DI                    DJ

                  3.0V           EG                        EH                     EI                    EJ

                  3.1V           FG                        FH                     FI                    FJ

Table 2. Factory-Trimmed Lower       and                   Upper Threshold Combinations            for  Two-Cell

Alkaline/NiCd/NiMH Applications

            VOLTAGES                                       UPPER THRESHOLD (HTH)

                        2.3V                               2.4V                   2.5V                  2.6V

                  1.6V           KQ                        KR                     KS                    KT

LOWER             1.7V           LQ                        LR                     LS                    LT

THRESHOLD         1.8V           MQ                        MR                     MS                    MT

(LTH)

                  1.9V           NQ                        NR                     NS                    NT

                  2.0V           OQ                        OR                     OS                    OT

                  2.1V           PQ                        PR                     PS                    PT

Table 3. Factory-Trimmed VCC Reset                         Table 4. VCC Reset Timeout Period Suffix

Threshold Levels                                           Guide

PART NO.                VCC NOMINAL                              TIMEOUT          ACTIVE TIMEOUT PERIOD (ms)

SUFFIX                  RESET                              PERIOD SUFFIX                MIN             MAX

       (_)              THRESHOLD (V)                             D3                    150             300

       T                3.075                                     D7                    1200            2400

       S                2.925

       R                2.625

       Z                2.313

       Y                2.188

       W                1.665

       V                1.575

           DC-to-DC Converter Application                  reduce system power consumption. The LBOL output

The MAX6441/MAX6442 triple-output battery monitors         indicates the battery is empty, and system power

can be used in conjunction with a DC-to-DC converter       should be disabled. By connecting LBOL to the SHDN

to power microprocessor systems using a single Li+         pin of the DC-to-DC converter, power to the microproces-

cell or two to three alkaline/NiCd/NiMH cells. The LBOH    sor is removed. Microprocessor power does not return

output indicates that the battery voltage is weak, and is  until the battery has recharged to a voltage greater than

used to warn the microprocessor of potential problems.     VLTH+ (see Figure 7).

Armed with this information, the microprocessor can

            ______________________________________________________________________________________                    11
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442                                                                                      Selector Guide

                          PART   OPEN-DRAIN            PUSH-PULL RESET  SINGLE LOW-                          DUAL LOW-BATTERY

                                          RESET                         BATTERY OUTPUT                          OUTPUT

                 MAX6439                  X               —                          X                                 —

                 MAX6440                  —               X                          X                                 —

                 MAX6441                  X               —                       —                                    X

                 MAX6442                  —               X                       —                                    X

                                Standard  Versions Table                Typical Application Circuit

                          PART               TOP MARK

                 MAX6439UTDHRD3                  ABMN                   DC/DC

                                                             Li+

                 MAX6439UTDHSD3                  ABMO        3.6V

                 MAX6439UTEHRD3                  ABMP

                 MAX6439UTEHSD3                  ABMQ                                       VCC                               VCC

                 MAX6439UTEIRD3                  ABMR                                MR              LBO               NMI

                 MAX6439UTEISD3                  ABMS                                       MAX6439                           µP

                 MAX6440UTDHRD3                  ABMT                                       MAX6440

                 MAX6440UTDHSD3                  ABMU                                VBATT           RESET             RESET

                 MAX6440UTEHRD3                  ABMV                                       GND                             GND

                 MAX6440UTEHSD3                  ABMW

                 MAX6440UTEIRD3                  ABMX

                 MAX6440UTEISD3                  ABMY

                 MAX6441KADHRD3                  AEEI                   Pin Configurations (continued)

                 MAX6441KADHSD3                  AEEJ

                 MAX6441KAEHRD3                  AEEK

                 MAX6441KAEHSD3                  AEEL                   TOP VIEW

                 MAX6441KAEIRD3                  AEEM                   VBATT     1                          8  VCC

                 MAX6441KAEISD3                  AEEN

                 MAX6442KADHRD3                  AEEO                   GND       2                          7  LBOL

                                                                                            MAX6441

                 MAX6442KADHSD3                  AEEP                   MR        3         MAX6442          6  LBOH

                 MAX6442KAEHRD3                  AEEQ                   LBOLH     4                          5  RESET

                 MAX6442KAEHSD3                  AEER

                 MAX6442KAEIRD3                  AEES                                       SOT23-8

                 MAX6442KAEISD3                  AEET

                                                                                                 Chip Information

                                                             TRANSISTOR COUNT: 1478

                                                             PROCESS: BiCMOS

                 12  ______________________________________________________________________________________
Low-Power, Single-/Dual-Level Battery Monitors

with Hysteresis and Integrated µP Reset

                                   Package Information                                                                                                  MAX6439–MAX6442

(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information,

go to www.maxim-ic.com/packages.)

                                                                                                                                         6LSOT.EPS

                                   PACKAGE OUTLINE, SOT 6L BODY

                                   21-0058                       G                      1

                                                                                           1

______________________________________________________________________________________                                                              13
                 Low-Power, Single-/Dual-Level Battery Monitors

                 with Hysteresis and Integrated µP Reset

MAX6439–MAX6442                                                                          Package Information (continued)

                 (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information,

                 go to www.maxim-ic.com/packages.)

                                                                      SEE DETAIL "A"                                                    SYMBOL              MIN         MAX                   SOT23, 8L .EPS

                                   b                        e                                                                           A                   0.90        1.45

                                            CL                                                                                          A1                  0.00        0.15

                                                                                                                                        A2                  0.90        1.30

                                                                                                                                        b                   0.28        0.45

                                                                                                                                        C                   0.09        0.20

                                                                                                                                        D                   2.80        3.00

                        CL                                                    CL                  E1                                    E                   2.60        3.00

                                                                   E                                                                    E1                  1.50        1.75

                                                                                                                                        L                   0.30        0.60

                                                                                                                                        L2                        0.25  BSC.

                        PIN 1                                                                                                           e                         0.65  BSC.

                     I.D. DOT

                     (SEE NOTE 6)                                                                                                       e1                        1.95  REF.

                                                                                                                                        0                   0∞                8∞

                                            e1

                                            D

                                                                                      C

                                            CL

                                                                                                                                                       L2

                     A      A2                                 A1                                                                                                       GAUGE  PLANE

                                                                                         SEATING  PLANE                    C

                                                                                                                                        L                         0

                     NOTE:

                     1. ALL DIMENSIONS ARE IN MILLIMETERS.

                     2. FOOT LENGTH MEASURED FROM LEAD TIP TO UPPER RADIUS OF                                                              DETAIL      "A"

                     HEEL OF THE LEAD PARALLEL TO SEATING PLANE C.

                     3. PACKAGE OUTLINE EXCLUSIVE OF MOLD FLASH & METAL BURR.

                     4. PACKAGE OUTLINE INCLUSIVE OF SOLDER PLATING.

                     5. COPLANARITY 4 MILS. MAX.

                     6. PIN 1 I.D. DOT IS 0.3 MM ÿ MIN. LOCATED ABOVE PIN 1.

                     7. SOLDER THICKNESS MEASURED AT FLAT SECTION OF LEAD                                                     PROPRIETARY INFORMATION

                                                                                                                              TITLE:

                     BETWEEN 0.08mm AND 0.15mm FROM LEAD TIP.                                                                 PACKAGE OUTLINE, SOT-23,                         8L BODY

                     8. MEETS JEDEC MO178.

                                                                                                                              APPROVAL      DOCUMENT CONTROL NO.                  REV.  1

                                                                                                                                                       21-0078                    D        1

                 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are

                 implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.

                 14  ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA                                                    94086 408-737-7600

                 ©   2005 Maxim Integrated Products         Printed USA                  is a registered trademark of Maxim Integrated Products, Inc.

小广播

MAX6442KACJVD7-T器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved