电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

LCS-30-C

器件型号:LCS-30-C
器件类别:热门应用    测试测量   
文件大小:6019.77KB,共10页
厂商名称:Curtis Industries
下载文档

器件描述

cntrl liq level 24vac chassis

参数
Datasheets:
Liquid Level Controls Catalog:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Controllers - Liquid, Level
Series: LCS
Type: High/Low Level
Voltage - Supply: 24VAC
Sensitivity: 0 ~ 100kOhm
Features: Adjustable Sensitivity, Auxiliary Contactor
Cable Length: -
Output Type: Relay
Contact Form: SPDT (1 Form C)
Contact Rating @ Voltage: 10A @ 120VAC
Mounting Type: Chassis Mount
Termination Style: Screw Terminal
Operating Temperature: 0°C ~ 60°C
Fluid Type: -
Weight: -

LCS-30-C器件文档内容

3
Selection Chart

Series         Page   Supply           Load Capacity                                Description and Special Notes
              Number  Voltage
                                                                                    Economical liquid level control sensitivity range
Curtis liquid level controls                                                       to 100,000 ohms
                                                                                    Low-cost liquid level control with sensitivity up to
ELS               3   120, 240VAC      1/4 HP, 10 amp non-inductive                 50,000 ohms
                                       120VAC, 1/3 HP, 240 VAC                      Liquid level control with built-in time delay
                                                                                    feature for standard applications up to 100,000
ELC               4   120, 240VAC      1/4 HP, 10 amp non-inductive                 ohms
                                                                                    Liquid level control with adjustable sensitivity
                                       120VAC, 1/3 HP, 240 VAC                      ranges for detection up to 100,000 ohms
                                                                                    Liquid level control with adjustable sensitivity
LCT               5   24, 120, 240VAC  1/4 HP, 10 amp non-inductive                 ranges for detection up to 3,00,000 ohms
                                                                                    Liquid level control with forward and reverse
                                       120VAC, 1/3 HP, 240 VAC                      operating modes, adjustable sensitivity to
                                                                                    100,000 ohms
LCS               6   24, 120, 240VAC 1/4 HP, 10 amp non-inductive                  Dual liquid level control with heater/pump
                                       120VAC, 1/3 HP, 240 VAC                      lockout feature, sensitivity range to 100,000
                                                                                    ohms
LHS               6   24, 120, 240VAC  1/6 HP, 10 amp non-inductive                 Rugged, compact contractors and enclosures
                                       120VAC, 1/3 HP, 240 VAC                      meeting NEMA 1, 3, 4, and 12 specifications
                                                                                    A variety of pressure, temperature and fitting
LC                7   24, 120, 240VAC 1/4 HP, 10 amp non-inductive                  options available
                                       120VAC, 1/3 HP, 240 VAC
                                                                                    Low-cost amplifier module for liquid level
DLC               8   24, 120, 240VAC 1/6 HP, 10 amp non-inductive                  applications

                                       120VAC, 1/3 HP, 240 VAC                      For precision photoelectric or temperature
                                                                                    applications
Accessories       9

Liquid level

probe

assemblies        9

RSA           10      24, 120, 240VAC

Curtis industrial controls

ELS           11      24, 120, 240VAC 1/6 HP, 10 amp non-inductive

                                       120VAC, 1/3 HP, 230 VAC

Curtis liquid level control principle of operation

Operating on the principle of conductivity (the ability of a liquid to              current, typically 500 microamperes, is introduced to a solid-state
conduct electricity), Curtis Liquid Level controls sense and control the            resistance-sending amplifier which provides sufficient gate signal to
level of almost any fluid or moist solid. These units are available with            trigger a silicon-controlled rectifier (SCR). The firing threshold is
fixed or adjustable setpoints to control levels in fluids having an                 accurate to within 2% of operating differential and is adjustable by
external circuit resistance up to 3,000,000 ohms. Typical solution                  means of a potentiometer. The output of the SCR is used to operate
resistivity is shown below.                                                         the plug-in control relay. When anticipated loads exceed that of the
                                                                                    standard relay, an auxiliary contactor is utilized.
Typical Liquid Resistivity
                                                                                    Control Models ELS, LCS/LHS, LCF and RSA are designed for
Liquid                Nominal Resistivity                                           forward mode operation. They interpret a decrease of external circuit
                       Range (ohms/CC)                                              resistance from setpoint as an "ON" signal. Model LCR is designed for
                                                                                    reverse mode operation. It energizes when external circuit resistance
acids, bases and salts ................................................ 0-20        increases above setpoint. Model DLC is intended primarily for pump
dilute acids .............................................................. 20-200  and heater level/lockout applications. See the appropriate catalog
milk, beer ........................................................... 200-2,000    sections for specific application information.
non-distilled water ......................................... 2,000-20,000
distilled water ............................................ 20,000-200,000         When selecting a liquid level control, several factors must be taken
                                                                                    into consideration. Questions arise as to what mode of operation is
In operation, two or more submerged liquid level probes pass a                      required, what is the resistivity range of the fluid to be controlled, is a
minute electrical current through the liquid to be controlled. This                 fixed or variable setpoint called for, are special functions required
                                                                                    such as a pump or heater lockout, etc. Use the connection diagrams
4                                                                                   to select the ideal control for your specific application.
Curtis liquid level controls

Model ELS
Economical unit with sensitivity
up to 100,000 ohms

Features

s Solid State Amplifier with SCR and Control Relay
s Low AC Signal Voltage
s Compact Printed Circuit Design
s 1/4" Quick-Connect Terminals
s Insensitive to Transients
s Built-in Holding Circuit for Differential Levels or Manual Reset
s Plug-in Dust-Tight Relay
s Recognized Under the Components Program of Underwriters

     Laboratories, Inc. Listed with Canadian Standards Association.

Specifications

                   Model                              Input Supply   Maximum Signal or Probe Voltage: 24VAC
                                                   120VAC, 50/60 Hz  Maximum Signal or Probe Current: 10MA
Input Supply:      ELS-1-A,B,C                     240VAC, 50/60 Hz  Control Relay: Single Pole Double Throw, Plug-in Type with Dust-Tight Cover
                   ELS-1-A,B,C                                       Load Contacts: SPST Rated 1/4 HP, 10 Amps, 120VAC
                                                     100,000 ohms
Maximum Allowable Supply Voltage Variation: 10%     50,000 ohms                           1/3 HP, 10 Amps, 240VAC
                                                      25,000 ohms    Ambient Operating Temperature: 32 F to 140 F
Maximum Power Consumption: 3 Watts                                   Standard Termination: .250" Quick-Connects

Detectable Range:  ELS-1,2-A
                   ELS-1,2-B
                   ELS-1,2-C

               Outline and Mounting Dimensions                                Connection Diagrams

                                                                     This is a fixed-sensitivity, forward mode control. The control relay is energized when
                                                                     liquid rises to contact the "H" probe. The control relay is pulled in and remains
                                                                     energized until liquid drops below the "L" probe.

Ordering           Typical Curtis Model Number                                ELS-1 -A-
Information
                   Model (Also refer to "Specifications" above)
                   Detectable Range (A-100 k ohms, B-50 k ohms, C-25 k ohms)
                   Enclosure specify only if necessary

                                N3-NEMA 3, N4NEMA 4 JIC

                   The composite number above reads as "an ELS amplifier for 120VAC supply, without enclosure, and with 100 K ohms sensitivity."

                   For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
                   For custom design or modification contact your area Curtis Representative or the factory direct.

                                                                                                                                                                    5
Curtis liquid level controls

Model ELC
Economical unit with sensitivity
up to 50,000 ohms

Features

s Compact, Solid-State Design
s Single Level, Forward Mode Operation
s Holding Circuit for Differential Levels, or Manual Reset
s Low AC Signal Voltage
s Transient-Protected Circuit, Positive ON/OFF Eliminates Relay

     Chatter
s Circuit Design Limits Short Circuit Probe Current to

     10MA/24VAC

Specifications

                Model                                 Input Supply

Input Supply:   ELC-1-S,D                          120VAC, 50/60 Hz  Control Relay: Plug-in Type with Dust-Tight Cover
                ELC-1-S,D                          240VAC, 50/60 Hz
                                                                     Probe Contacts: SPDT internally connected

Maximum Allowable Supply Voltage Variation: 10%                    Load Contacts: SPDT (ELC-1,2-S) or DPDT (ELC-1,2-D)
                                                                        Rated 10 amp Non-inductive, 120VAC, 1/4 HP
Maximum Power Consumption: 3 Watts                                       1/3 HP at 240VAC

Detectable Range: Up to 50,000 ohms

Operating Point Differential: 3% (Typical)                           Ambient Operating Temperature: +32 F to +140 F

Maximum Signal or Probe Voltage: 24VAC                               Standard Termination:  .250" Quick-Connect

Maximum Signal or Probe Current: 10MA                                Mounting Style: 4 Standoffs

               Outline and Mounting Dimensions                                              Connection Diagrams

                                                                     This is a fixed-sensitivity, forward mode control. The control relay is energized when
                                                                     liquid rises to contact the "H" probe. The control relay is pulled in and remains
                                                                     energized until liquid drops below the "L" probe.

Ordering        Typical Curtis Model Number                                                       ELC-1 -S-
Information
                Model (Also refer to "Specifications" above)
6               Detectable Range (A-100 k ohms, B-50 k ohms, C-25 k ohms)
                Enclosure specify only if necessary

                             N3-NEMA 3, N4NEMA 4 JIC

                The composite number above reads as "an ELC amplifier for 120VAC supply SPDT Output and without Enclosure."

                For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
                For custom design or modification contact your area Curtis representative or the factory direct.
Curtis liquid level control with
time delay

Model LCT

Features

s Low Cost Control for Standard Applications up to 100,000 ohms
s Built-in Delay-on-Make
s Interchangeable with Curtis Model LCS Liquid Level Controls
s Solid-State Amplifier with Potentiometer for Signal Sensitivity

     Adjustment
s Positive ON/OFF Operation Eliminates Relay Chatter
s Circuit Limits Short-Circuit Probe Current to 10MA/24VAC
s Holding Circuit for Differential Levels, or Manual Reset
s Pre-wired Auxiliary Contactor Available for Handling Heavy

     Loads and Motor Ratings Exceeding Capacity of Plug-in Relay

Specifications                                                              Delay on Release: 0.5 sec. 50%
                                                                            Open Circuit Probe Voltage: 24VAC
                Model                                         Input Supply  Short Circuit Probe Current: 10MA
                                                                            Control Relay: Plug-in type with dust cover
Input Supply:   LCT-10                             120VAC 10%, 50/60 Hz    Contact Rating: 10 amp non-inductive, 1/4 HP at 120VAC, 1/3 HP at 240VAC
                LCT-20                             240VAC 10%, 50/60 Hz    Auxiliary Contactor: DPST-NO-DB, rated 1 HP at 120VAC, 2 HP at 240VAC
                LCT-30                             24VAC 10%, 50/60 Hz.    Ambient Operating Temperature: 0 C to +60 C
                                                                            Standard Termination: Barrier-type terminal blocks accepting wire up to No.
Maximum Allowable Supply Voltage Variation: 10%                           12AWG. Auxiliary contactor has combination screw/double .250" quick-connects
                                                                            Mounting Style: Flange
Maximum Power Consumption: 3 Watts                                          Outside Dimensions: 5-1/2" long x 4-1/8" wide x 2-13/16" high

Sensitivity Range: 1,000 to 100,000 ohms

Detectable Range: Up to 100,000 ohms

Operating Point Differential: 3% (Typical)

Time Delay: Delay on Operate: 3 sec: 50%
(Other values between 0.5 and 10 sec. available on request.)

               Outline and Mounting Dimensions                              Connection Diagrams

                                                                            Model LCT is a forward mode control. The control relay is energized when liquid rises to
                                                                            contact the "H" probe. The time delay on operate is 3 seconds nominal and 0.5 seconds
                                                                            on release. Other values between 0.5 and 10 seconds are available on request. The
                                                                            control relay is pulled in and remains energized until liquid drops below the "L" probe.
                                                                            Sensitivity is adjustable.

Ordering        Typical Curtis Model Number                                 LCT-20 - -
Information
                Model (Also refer to "Specifications" above)
                Contactor (add "C" if desired)
                Enclosure specify only if necessary

                             N3-NEMA 3, N3CNEMA 3/
                             Contactor, N4 NEMA 4 JIC

                The composite number above reads as an LCT amplifier for 240VAC supply, without enclosure and without contactor.
                For further information on catalog listed controls contact your area Curtis Representative or Curtis distributor.
                For custom design or modification contact your area Curtis Representative or the factory direct.

                                                                                                                                                                 7
Curtis liquid level controls with

Models LCS/LHS

Two sensitivity ranges for
detection up to 3,000,000 ohms

Features

s Low cost Model LCS for Standard Applications up to 100,000 ohms
s High-Sensitivity Model LHS for Special Applications from 100,000 to

     3,000,000 ohms
s Solid-State Amplifier with Potentiometer for Signal Sensitivity

     Adjustment
s Positive ON/OFF Operation Eliminates Relay Chatter
s Circuit Limits Short Circuit Probe Current to 10MA/24VAC
s Holding Circuit for Differential Levels, or Manual Reset
s Pre-Wired Auxiliary Contactor Available for Handling Heavy Loads

     and Motor Ratings Exceeding Capacity of Plug-In Relay

Specifications                                                                Short Circuit Probe Current: 10MA
                                                                              Control Relay: Plug-in type with dust cover
                Model                              Input Supply               Probe Contacts: Internally Connected for Holding Circuit
                                                                              Load Contacts: LCS SPDT, 1/4 HP, 10 amp Non-inductive, 120VAC 1/3 HP at 240 VAC
Input Supply:   LCS-10/LHS-1                       120VAC, 50/60 Hz           LHS SPDT, 1/6 HP, 10 amp Non-inductive, 120VAC 1/3 HP at 240VAC
                LCS-20/LHS-2                       240VAC, 50/60 Hz           Auxiliary Contactor: DPST-NO-DB, rated 1 HP at 120VAC, 2 HP at 240VAC
                                                   24VAC, 50/60 Hz.           Ambient Operating Temperature: +32 F to +140 F
                    LCS-30                                                    Standard Termination: Barrier-type terminal blocks accepting wire up to No.
                                                                              12AWG. Auxiliary contactor has combination screw/double .250" quick-connects
Maximum Allowable Supply Voltage Variation: 10%                             Mounting Style: Flange

Maximum Power Consumption: 3 Watts

Detectable Range: Up to 100,000 ohms (LCS); Up to 3,000,000 ohms (LHS)

Adjustable Range: 1,000 to 100,000 ohms (LCS); 1,000 to 3,000,000 ohms (LHS)

Operating Point Differential: 3% (Typical)

Signal or Probe Voltage: 24VAC
Maximum Signal or Probe Current: 10MA

Outline and Mounting                                                          Connection Diagrams

                                            Models LCS/LHS is a forward mode control. The control relay is energized when liquid rises to contact the "H" probe. The control
                                            relay is pulled in and remains energized until liquid drops below the "L" probe. Sensitivity is adjustable.

Ordering        Typical Curtis Model Number                                   LCS-20 - -
Information
                Model (Also refer to "Specifications" above)
8               Contactor (add "C" if desired)
                Enclosure specify only if necessary

                             N3-NEMA 3, N3CNEMA 3/
                             Contactor, N4 NEMA 4 JIC

                The composite number above reads as an LCS amplifier for 240VAC supply, without enclosure and without contactor.
                For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
                For custom design or modification contact your area Curtis representative or the factory direct.
adjustable setpoints

Model LC

Forward or reverse, mode with
single or differential level operation

Features                                                              Specifications

s Adjustable Sensitivity up to 100,000 ohms                           Model                        Input Supply         Model   Input Supply
s Solid State Amplifier with SCR and Control Relay
s Circuit Limits Short Circuit Probe Current 10MA/24VAC               Input Supply: LC-F-1         120VAC, 50/60 Hz     LC-R-1  120VAC, 50/60 Hz
s Recommended for Applications Having Longer Than Average                                  LC-F-2  240VAC, 50/60 Hz     LC-R-2  240VAC, 50/60 Hz
                                                                                           LC-F-3  24VAC, 50/60 Hz      LC-R-3  24VAC, 50/60 Hz
     Probe Runs. (Resultant Line Capacitance can be Compensated
     for by Adding a Capacitor (CX) of Equivalent Value to Available  Maximum Allowable Supply Voltage Variation: 10%
     Terminals or the Control)
s Temperature-Stabilized from +32 F to +140 F                       Maximum Power Consumption: 3 Watts
s Shielded, Grounded Isolation Transformer
s Low Power Consumption                                               Detectable Range: Up to 100,000 ohms
s Auxiliary Contactor Available
                                                                      Adjustable Range: 1,000 to 100,000 ohms
         Outline and Mounting Dimensions
                                                                      Operating Point Differential: 3% (Typical)

                                                                      Signal or Probe Voltage: 24VAC
                                                                      Maximum Signal or Probe Current: 10MA

                                                                      Control Relay: Plug-in type with dust cover

                                                                      Probe Contacts: Internally connected for holding circuit

                                                                      Load Contacts: DPDT rated 10 amp, Non-inductive/120VAC, 1/4 HP at 240VAC

                                                                      Auxiliary Contactor: DPST-NO-DB, rated 1 HP at 120VAC, 2 HP at 240VAC

                                                                      Ambient Operating Temperature: +32 F to +140 F

                                                                      Standard Termination: Barrier-type terminal blocks for wire up to No. 12AWG.
                                                                      Auxiliary contactor has combination screw/double .250" quick-connects. Optional
                                                                      SPDT contacts have .250" quick-connects

                                                                      Options: Alarm and indicator lamp for enclosure-mounted controls, high impedance
                                                                      relays available for extended control dropout time.=

                                                                      Mounting Style: Standoffs

             Connection Diagrams  Model LC Forward Mode
                                  Control energizes when liquid reaches "H". Con-
                                  trol de-energizes when liquid falls below "L" and
                                  remains in an off state until liquid again reaches
                                  "H". This control maintains a liquid level between
                                  "H" and "L" and will not chatter due to surface ripple.

                                  Single Level Operation (Not Illustrated)
                                  both the LC-F and LC-R may be used without the
                                  "L" Probe. Operation without the "L" Probe gives a
                                  very small differential between the energize and
                                  de-energize levels. This may result in chattering of
                                  the control if splashing or ripple is present at the
                                  liquid surface.

                                  Model LC Reverse Mode
                                  Control Energizes when liquid falls below "L. Con-
                                  trol remains energized until liquid rises past "L" and
                                  contacts "H". Control de-energizes when liquid
                                  reaches "H" and remains in an off state until liquid
                                  again falls below "L. This control maintains a liquid
                                  level between "L" and "H" and will not chatter due
                                  to surface ripple.

Ordering     Typical Curtis Model Number                                                           LC-R-1 - -
Information
             Model (Also refer to "Specifications" above)
               Operational Mode (F Forward, R Reverse)

             Contactor (add "C" if desired)
             Enclosure specify only if necessary

                          N3-NEMA 3, N3CNEMA 3/
                          Contactor, N4 NEMA 4 JIC

             The composite number above reads as an LC amplifier with reverse mode, for 120VAC supply, without enclosure and without contactor."
             For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
             For custom design or modification contact your area Curtis representative or the factory direct.

                                                                                                                                                              9
Curtis liquid level controls

Models DLC

Dual-level control with
lockout feature

Features

s Ideal for Pump and Heater Applications Requiring Lockout in the
     Event of Loss of Water or Product Being Controlled

s Circuit Design Limits Short Circuit Probe Current to 10MA/24VAC
s Three-Probe Circuit Eliminates "Hunting" or Relay Chatter
s Built-in Holding Circuit for Differential Levels or Manual Reset
s Has Provision for Priming Switch for Applications Requiring Manual

     Priming of System
s Solid-State Amplifier with SCR and Control Relay
s Sensitivity to 100,000 ohms

Specifications

                Model                              Input Supply

Input Supply:   DLC-1                              120VAC, 50/60 Hz                     Maximum Signal or Probe Current: 10MA
                DLC-2                              240VAC, 50/60 Hz                     Control Relay: Plug-in types with dust cover
                DLC-3                              24VAC, 50/60 Hz.                     Probe Contacts: Internally connected for holding circuit
                                                                                        Load Contacts: 1/6 HP, 10 amp, Non-inductive/120VAC, 1/3 HP at 240VAC
Maximum Allowable Supply Voltage Variation: 10%
                                                                                              One side of No. 1 relay actuates fill water solenoid valve, a second set of contacts
Maximum Power Consumption: 3 Watts                                                            function as an internally connected holding circuit. One side of No. 2 relay is used
                                                                                              to operate a heater load contactor.
Sensitivity Range: External circuit sensitivity fixed at 100,000 ohms; Lockout circuit  Ambient Operating Temperature: +32 F to +140 F
sensitivity fixed at 15,000 ohms                                                        Standard Termination: .250" quick-connects

Operating Point Differential: 3% (Typical)

Maximum Signal or Probe Voltage: 24VAC

    Outline and Mounting Dimensions                                                     Description and Special Notes

                                                   The DLC control maintains liquids between a low and a high level. Activating the main switch on this dual-
                                                   relay unit pulls in control relay No. 1 and starts filling boiler tank through the solenoid valve. When liquid rises
                                                   to "XL", minimum level, lockout control relay No. 2 energizes to operate the pump, heater core or contactor.
                                                   The solenoid valve continues to fill the tank until liquid reaches the "H" probe. When the liquid drops below the
                                                   "L" probe, the solenoid fill valve is again activated. Relay No. 2, he lockout control, remains energized as long
                                                   as liquid level remains above "XL" minimum level.

Ordering        Typical Curtis Model Number                                                                        DLC-1 - -

Information     Model (Also refer to "Specifications" above)

                Contactor (add "C" if desired)

                Enclosure specify only if necessary

                                            N3-NEMA 3, N3CNEMA 3/

                                            Contactor, N4 NEMA 4 JIC

The composite number above reads as a "DLC amplifier for 120VAC supply, without enclosure and without contactor.
Unless otherwise noted, when a contactor is ordered for the DLC unit, it is wired into the output of the No. 2 (heater control) relay. Contactors may be wired into the output of the No. 1
(solenoid valve control) relay or both No. 1 and No. 2 relays, as application may require. Specify with order. Refer to "Control Accessories," page 7, for additional information.

For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
For custom design or modification contact your area Curtis representative or the factory direct.

10
Curtis liquid level probe assemblies

P Series
Probes for almost any
pressure/temperature requirement

Five basic probe types and 14 model variations provide design versatility matched to
your specific application. Choose from single, dual or multi-probe designs in PVC or
nylon fittings. All probes feature 316 stainless steel electrodes with standard lengths
ranging up to six feet, in one-foot increments. Pressure/temperature limits range as
high as 2500 lbs./700 F. Covered probes are offered for applications subject to
unusually adverse environments or stringent safety codes.

Model EP                                                   Model SP                                                     Models HTPP - HTPGP
Economy probe designed for budget systems. Available       Simple probe designed with adjustable probe length fea-      High temperature, high pressure 3/8" NPT probe designed
in NPT sizes 3/4" (Single probe), 1" (Dual probe), 1-1/2"  ture. Must be used with conductive container only. Avail-    to withstand hydrostatic pressures to 2500 psi and tem-
(Triple probe) with Nylon Hex fittings.                    able in probe size diameters of 1/8", 3/16" or 1/4" (i.e.    peratures to 700 F. Standard Model HTPP does not con-
                                                           SP125, SP187, SP250).                                        tain added threaded stud for common ground connection,
                                                                                                                        when required specify HTPGP Model. Constructed from
                                                                                                                        18-8 non-magnetic stainless steel with alumina insulation.

                                                           Model CP
                                                           Covered Probe designed for high humidity environments.
                                                           Probe headers are splash-proof and moisture-tight. Avail-
                                                           able in NPT fitting sizes 1-1/2" for dual probe systems and
                                                           2" for triple or quadruple probe systems.

Accessories                                                Standard Control Models ELS, LCS/LHS, LC, RSA, DLC, and PCT are open-style.
                                                           Models with contactors are attached to a 6-7/8" x 8-3/4" panel. NEMA 3 and MEA 4-
Control enclosures for                                     JIC enclosures are offered to fit above models with or without contactor mounting
hostile environments                                       panels. Alarm and indicator lamp options are also available. Contact factory or your
                                                           local representative for additional information.

NEMA 3 Enclosures Weather-Resistant                      NEMA 4-JIC Enclosures Water Tight and Oil Tight            Auxiliary Contactors For Loads
for Outdoor Applications                                   Intended for use in areas which are regularly hosed down.    Exceeding That of Standard Relays
Designed to exclude rain, snow and sleet, thee durable     They are suitable for outdoor, shipdeck, dairy or brewery    When anticipated loads exceed the 10 amp/120VAC rat-
enclosures may also be used indoors wherever dripping      applications. Enclosures are fabricated of extra-heavy 14-   ing of relays furnished with our standard controls, use of a
water presents a problem. Construction features heavy-     gauge steel with welded seams. Construction also fea-        contactor is necessary. These small, ruggedly built units
gauge steel finished in satin gray enamel. Enclosures ac-  tures external mounting feet and solid neoprene cover        are available in 24, 120 and 240VAC coil voltages to match
cepting standard control models are designated N3, while   gasket. These grey hammertone enamel-finished units          the control input supply voltage. Contactors feature heavy-
those accepting the larger contactor mounting panels are   accept standard and contactor mounting panel controls.       duty DPST-NO-DB contacts rated 1HP/120VAC or 2HP/
designated N3C. Enclosures also meet NEMA I specifica-     Enclosures also meet NEMA 12 for dust, dirt and oil pro-     240VAC. Terminals are No. 10 pressure screws with .250"
tions for general purpose dust resistance.                 tection.                                                     double quick-connect tabs. Contactor/control assembles
                                                                                                                        are prewired for customer convenience.

Any standoff or flange-mounted control may be ordered with the auxiliary contactor. Track-mounted controls are          Any standoff or flange-mounted control may be ordered
available with auxiliary contactors on special order only. Contact factory for additional info.                         with the auxiliary contactor. Track-mounted controls are
                                                                                                                        available with auxiliary contactors on special order only.
                                                                                                                        Contact factory for additional information.

                                                                                                                        11
Curtis low cost amplifier module
for liquid level applications

Model RSA
Control-Trak component

Features                                                          Specifications

s Inexpensive, Compact Circuitry is Compatible with any Trans-    Input Supply:  Model     Input Supply
     ducer Exhibiting 100,000 ohms Resistance or Less
                                                                                 RSA-1  120VAC, 50/60 Hz
s Designed to Fit Curtis TR1 or TR3 Snap-In Track Intended for                   RSA-2  240VAC/ 50/60 Hz
                                                                                 RSA-3  24VAC, 50/60 Hz

Use with Curtis RS2, RS4, RS6, RS12, RS15 or RS16 Relay           Maximum Allowable Supply Voltage Variation: 10%

Socket Assemblies (See Curtis Relay Socket Catalog)               Maximum Power Consumption: 1 W without relay

s Ideal for Custom, Modified or Experimental Circuits Control/ Detectable Range: Up to 100,000 ohms

Relay Socket Combination Provides Access to the Several           Adjustable Range: 1,000 to 100,000 ohms

Hundred Relay Styles Available from Most Relay Manufacturers Operating Point Differential: 3% (Typical)

s Devices Other Than Relays, such as Solenoids or Valve           Maximum Signal or Probe Voltage: 24VAC
     Actuators may be Operated Directly Off the Module Providing  Maximum Signal or Probe Current: 10MA
     that They are Rated 24VDC with Impedance Greater than 250
     ohms                                                         Control Relay: Customer furnished See Curtis Relay Socket Catalog for complete
                                                                  list of various snap-in assemblies

                                                                  Control Output: 90MA @ 24VDC

s Includes Fully Adjustable Setpoint and Circuit Designed to Limit Ambient Operating Temperature: 0 C to +60 C or 32 F

Maximum Direct-Short Transducer Current to 10MA/24VAC             Standard Termination: .110" quick-connects

Outline and Mounting Dimensions

Operation                                                         Model RSA Amplifier Module accepts any liquid level transducer dis-
                                                                  playing less than 100,000 ohms resistance. As an example of its opera-
Ordering                                                          tion as a liquid level control, the control remains de-energized until liquid
Information                                                       rises to contact the "H" probe. The resultant decrease in external circuit
                                                                  resistance from setpoint will energize output. Output remains energized
                                                                  until liquid again drops below the "H" probe. Sensitivity of the external
                                                                  circuit resistance setpoint is fully adjustable up to 100,000 ohms. Model
                                                                  RSA is designed to work in conjunction with track-mounted, customer
                                                                  supplied relays. However, the 90MA/24VDC output is sufficient to oper-
                                                                  ate many solenoid and valve devices directly when minimum impedance
                                                                  exceeds 250 ohms.

             Typical Curtis Model Number                                                RSA-1 -TR -

             Basic Amplifier Type (Also refer to "Specifications" above)
             Mounting (TR-Track, S-Standoff)

The composite number above reads as a "RSA amplifier for 120VAC supply." Model is track mounted (track ordered separately see page 11.) An auxiliary contactor offered as
a track-mounted accessory is available on special request only. Track-type units cannot be enclosure-mounted. Contact factory for additional information.

For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
For custom design or modification contact your area Curtis representative or the factory direct.

12
Curtis resistance sensing amplifier for

photoelectric, temperature and process control

Model PCT

Features

s Zener Diode-Regulated Power Supply Limits Operating Point

   Variations to Less than 0.5%                                  Specifications

s Standard Adjustable Resistance Sensing Range is Sensitive to      Model                        Input Supply

   100,000 ohms but can be extended to 250,000 ohms              Input Supply: PCT-1          120VAC, 50/60 Hz
                                                                                       PCT-2  240VAC/ 50/60 Hz
s  Has Provision for Remote Potentiometer Adjustment of Operat-                               24VAC, 50/60 Hz

   ing Setpoint as well as Built-In Time Delay which can be         PCT-3

   Modified to Meet Individual Customer Specifications           Maximum Allowable Supply Voltage Variation: 10%

s May be Wired for Light or Dark Energizing Operation            Maximum Power Consumption: 3.5 Watts
s Circuit Design Limits Short Circuit Transducer Current to a
                                                                 Detectable Range: Up to 100,000 ohms Standard; may be extended to 250,000
     Maximum 4MA/9VDC                                            ohms
s Auxiliary Contactor Available for Loads Exceeding Capacity of
                                                                 Adjustable Range: 1,000 to 100,000 ohms Standard; 1,000 to 250,000 ohms for
                                                                 extended sensitivity circuits

     Plug-in Relay                                               Operating Point Differential: 1% (With Sensing Element Resistance Above 15k
s Differential Adjustment Provided                               ohms) Typical
s Auxiliary Contactor Available for Loads Exceeding Capacity of  Maximum Signal or Probe Voltage (Element Exhibiting Infinite Resistance): 9VDC
                                                                 Maximum Signal or Probe Current: 4MA
     Plug-in Relay                                               Control Relay: DPDT Plug-In Type with Cover

   Outline and Mounting Dimensions                               Load Contacts: 1/6 HP, 10 amp, Non-inductive/120VAC; 1/3 HP at 230VAC
                                                                 Ambient Operating Temperature: -25 F to +140 F

                                                                 Standard Termination: Barrier-Type Terminal Blocks.

                                                                                              Accepting Wire up to No. 12AWG

                                                                 Mounting Style: Flange

   Operation                                                     Model PCT control may be wired to energize the control relay following
                                                                 either an increase or a decrease in external circuit resistance. Unit pro-
                                                                 vides a .25MA/9VDC signal to a variable resistance sensing element. A
                                                                 control-mounted potentiometer allows adjustment of pull-in or drop-out point.
                                                                 The unit has provision for extension of the operating point as well as re-
                                                                 mote potentiometer adjustment. A built-in time delay eliminates false
                                                                 riggering due to minor sensing element impulses. Standard response time,
                                                                 typically 100 milliseconds, can be altered by changing the value of capaci-
                                                                 tor C2. Provides a response time of 10 to 15 milliseconds.

Ordering      Typical Curtis Model Number                                                     PCT-1 - -
Information
              Basic Amplifier Type (Also refer to "Specifications"
              above)
              Contactor (if desired add "C")
              Enclosure specify only if necessary

                           (N3 NEMA 3, N3C NEMA 3/
                           Contactor, N4 NEMA 4 JIC

The composite number above reads as a "PCT amplifier for 120VAC supply without contactor and less enclosure." Contact factory for additional information.

For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
For custom design or modification contact your area Curtis representative or the factory direct.

                                                                                                                                                                                  13
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved