器件描述

CONTACTOR 30 KVAR 110V AC

文档预览

LC1DPKF7器件文档内容

TeSys Solution

           TeSys D contactors
           for capacitor switching

Why compensate for reactive energy?

1- To reduce your electricity bills by eliminating charges for excess reactive energy consumed.
   This consumption is generated by various types of load: transformers, motors, air-conditioning
   units, ballasts, etc.

2- To improve the quality of the energy provided by certain mains supplies.

How to compensate for reactive energy?

By using capacitor-based power factor correction equipment.

How does this impact power switching?

Capacitor switching is accompanied by transient phenomena resulting from the capacitor load,
which generate very high transient currents. TeSys D contactors for capacitor switching are
specially designed to commutate and limit such current peaks at energizing.

                                        Benefits

                                                                          Opt for energy savings
                                                                          and quality
                                                                                  Reduce your electricity bills
                                                                                  Control the quality of your energy

                                                                          Opt for simplicity: no more
                                                                          calculations needed
                                                                                  Contactor rated in kVAR
                                                                                  Sized to absorb current peaks
                                                                                  Optimized number of sales

                                                                                  references
                                                                                  Common accessories with

                                                                                   the TeSys D contactor range

                                                                          Opt for efficiency
                                                                                  300,000 switching operations

                                                                                  guaranteed
                                                                                  Shorter installation time
                                                                                  Smaller overall size due to the

                                                                                  compact design of TeSys D
                                                                                  contactors
TeSys Solution

Characteristics

The impedance of any electrical circuit has both an inductive and a resistive component.
Capacitors, together with such circuits, form oscillatory circuits which can, when switched on, give rise to high
transient currents (> 180 ln) at high frequencies (about 15 kHz).
As a general rule, the peak current at energizing is lower when:

    Mains inductances are high
    Line transformer ratings are low
    The transformer short-circuit voltage is high
    The ratio between the sum of the ratings of the capacitors already switched into the circuit and that of

     the capacitors to be switched in is small (for multiple-step capacitor banks).

In practice, the current peak is often incompatible with the characteristics of standard-technology contactors.
It is therefore necessary:

    Either to limit this current peak by increasing the inductance of the mains supply by inserting choke inductors
     and by calculating the size of the standard contactor to be used.

    Or to use special contactors (early make poles, high pressure at the poles, contact materials, etc.).

TeSys LC1 DK contactors have been specially designed for switching 3-phase, single- or multiple-step capacitor
banks. They are compliant with the IEC 60947-4-1 standard, according to AC-6b utilization category, and are UL, CSA
and CCC certified.

These products provide a ready-to-use solution.

Selection guide

Contactors                         LC1D      F  K                   B7

Operating power as per    13 kVAR            F
IEC 60947-4-1             16 kVAR            G
AC-6b at 400V, 50/60Hz,   20 kVAR            L
T<60C                    25 kVAR            M
                          30 kVAR            P
Capacitor switching       40 kVAR            T
AC Coil voltage, 50/60Hz  63 kVAR            W*

                          24V                                    K
                          48V
                          110V                                      B7
                          120V
                          220V                                      E7
                          230V
                          240V                                      F7
                          380V
                          400V                                      G7  TeSys LC1DFK
                          415V
                          440V                                      M7  TeSys LC1DGK

                                                                    P7

                                                                    U7                TeSys LC1DPK
                                                                                      TeSys LC1DTK
                                                                    Q7

                                                                    V7

                                                                    N7

                                                                    R7

* Complete suffix in this case being WK12                                                                                                                                       ART.8345242011 - Schneider Electric - All right reserved

Schneider Electric Industries SAS               As standards, specifications and designs change from time to time, please ask for confirmation
35, rue Joseph Monier                           of the information given in this publication.
CS 30323
F- 92506 Rueil Malmaison Cedex                         This document has been printed on ecological paper

RCS Nanterre 954 503 439                        Design: Schneider Electric
Capital social 896 313 776                      Photos: Schneider Electric
www.schneider-electric.com                      Printed by Altavia Connection - made in France

DIA1ED1080306EN                                                                                                                                                          09/2011
                   References5   TeSys contactors

                   LC1 DFKp.     For switching 3-phase capacitor banks,
                   LC1 DPKp.     used for power factor correction,
                   References :
                   page 3        Direct connection without choke inductors
                   2
PB107881_32_r.eps                Special contactors

                                 Special contactors LC1 DpK are designed for switching 3-phase, single or multiple-
                                 step capacitor banks. The contactors are conform to standard IEC 60947-4-1
                                 according to the AC-6b category of use and are UL, CSA and CCC certified.

                                 Contactor applications

                                 Specification
                                 Contactors fitted with a block of early make poles and damping resistors (external
                                 resistive wires), limiting the value of the current on closing to 60 In max.
                                 This current limitation increases the life of all the components of the installation, in
                                 particular that of the fuses and capacitors.
                                 The design of the add-on block ensures safety and long life of the installation.

                                 Operating conditions
                                 There is no need to use choke inductors for either single or multiple-step
                                 capacitor banks.
                                 Short-circuit protection must be provided by gI type fuses rated at 1.7...2 In.

                                 Maximum operational power
                                 The power values given in the selection table below are for the following operating
                                 conditions:

                                 Prospective peak current at            LC1 DpK             200 In
                                 switch-on
                                 Maximum operating rate                 LC1 DFK, DGK, DLK, DMK 240 operating cycles/hour

                                 Electrical durability at nominal load  LC1 DPK, DTK, DWK   100 operating cycles/hour

                                                                        All contactor ratings 400 V 300 000 operating cycles

                                                                                            690 V 200 000 operating cycles

PB107885_28_r.eps                Operational power (1)    Instantaneous Tightening          Basic reference, to be  Weight
                                 according to
                                 IEC 60947-4-1, AC-6b     auxiliary              torque of  completed by adding
                                 50/60 Hz,  y 60 C                                         the voltage code (2)
                                                          contacts               power

                                                                                 terminals

                                 230 V 400 V 440 V 690 V

                                     415 V

                                 kVAR kVAR kVAR kVAR N/O N/C N.m                                                      kg
                                                                                                                    0.530
                                 7   13 13 21 1                         2        1.7        LC1 DFKpp               0.530
                                                                                            LC1 DGKpp               0.570
                                 9   16 17 27 1                         2        1.7        LC1 DLKpp               0.570
                                                                                            LC1 DMKpp               1.070
                                 11  20 21 33 1                         2        2.5        LC1 DPKpp

                                 14  25 27 42 1                         2        2.5

                                 17  30 32 50 1                         2        5

                                 22  40 43 67 1                         2        5          LC1 DTKpp               1.070

                                 35  63 67 104 1                        2        9          LC1 DWK12pp             1.650

                                 Switching of multiple-step capacitor banks (with equal or different power ratings)

                                 The correct contactor for each step is selected from the above table, according to the power
                                 rating of the step to be switched.
                                 Example: 50 kVAR 3-step capacitor bank. Temperature: 40 C and U = 400 V or 440 V.
                                 One 25 kVAR step: contactor LC1 DMK, one 15 kVAR step: contactor LC1 DGK, and one 10
                                 kVAR step: contactor LC1 DFK.
                                 (1) Operational power of the contactor according to the scheme on the page opposite.
                                 (2) Standard control circuit voltages (the delivery time is variable, please consult your Regional

                                     Sales Office):

                                  Volts 24 48 110 120 220 230 240 380 400 415 440

                                 50/60 Hz B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7

                                     Version : 1.0      14/06/2011                                       TES02000-EN
              Dimensions,                                                                         TeSys contactors
              schemes
                                                                                                  For switching 3-phase capacitor banks,
              Dimensions                                                                          used for power factor correction

               LC1DFK, DGK                                                                         LC1DLK, DMK

DB402404.eps

   91
                                                    77

                                                                                                                                                          DB402405.eps

                                                                                     103
                                                                                                                                      77

                              121                                       45                                 127                                                               45

               LC1            Type of fixing                                                       LC1     Type of fixing              See pages 5/94 and 5/95
              DFK             LC1D18 See pages 5/94 and 5/95                                      DLK      LC1D25                      See pages 5/94 and 5/95
              DGK             LC1D18 See pages 5/94 and 5/95                                      DMK      LC1D32

              LC1DPK, DTK                                                                          LC1DWK

DB402406.eps                                                                        DB402407.eps

              166                                                  113                            180                                                                   127

                                    156                                     55                                                                                                                                5

               LC1            Type of fixing                                                       LC1                  154                                                                           85  3
              DPK             LC1D40A See pages 5/94 and 5/95                                     DWK                                                                   See pages 5/94 and 5/95
              DTK             LC1D65A See pages 5/94 and 5/95                                              Type of fixing
                                                                                                            LC1D80

DB402403.eps  Schemes

              LC1DpK

                                                               -R

                    13 21                                                       31

                    NO NC     1/L1  3/L2  5/L3                              NC

              A1

              A2              2/T1  4/T2  6/T3  -R
                       14 22
                                                                            32

                                                                                                  R = Pre-wired resistor connections.

              References :                                                          Version : 1.0               14/06/2011
              page 2
              TES02000-EN
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved