电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

K3SC-10 AC100-240

器件型号:K3SC-10 AC100-240
器件类别:热门应用    机电/工控/自动化   
文件大小:10035.17KB,共9页
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

控制器 RS-232/usbto-422/485 converter

参数
制造商: Omron
产品种类: 控制器
RoHS:
模拟/数字: Analog
控制方法: ON/OFF
类型: Interface Converter
电压额定值: 100 VAC to 240 VAC
安装: DIN Rail
大小: 30 x 80 x 78
输入类型: AC

K3SC-10 AC100-240器件文档内容

Interface Converter

K3SC

                                                                                                                      CSM_K3SC_DS_E_3_1

A compact converter that allows

communications between RS-232C/USB and

RS-422/485 devices. Ideal for industrial

applications.

• Allows communications between RS-232C/USB (Universal

Serial Bus) and RS-422/485 devices.

• Applicable in FA environments: Has passed environment

resistance tests equivalent to those for control devices.

• CE marking (except for USB).

• UL/CSA certification (mark license recognition).

• Compact 30-mm-wide body supports both screw-mounting and

DIN track mounting.

• Operation either with or without echoback available.

• Functionality to convert between USB and RS-232C

communications added.

• USB driver providing virtual communications port for USB

communications is available.

Note: To use USB communications, the USB driver for the K3SC must be                  Refer  to  Safety  Precautions  on page 8.

downloaded from the OMRON web site.

Application Examples

• Data can be transferred between computers (using the USB port if

there is no RS-232C port) and field devices.

• Using two K3SC Units enables long-distance communications between

devices connected via RS-232C.

Ordering Information

■ List of Models

Appearance                                    Size (mm)               Power supply voltage                            Model

                                30 × 80 × 78 (W × H × D)              100 to 240 VAC             K3SC-10 100 to 240 VAC

                                                                      24 VAC/VDC                 K3SC-10 24 VAC/VDC

                                                                                                                                         1
                                                                                                                                K3SC

■ Accessories (Order Separately)

Adapter for RS-232C              Serial Cable and K3SC (D-Sub, 9-pin,                                male)

Appearance                                                       Wiring diagram                                          Model

                                                                 D-Sub, 9-pin                        K32-23209

                                                                 Pin  Signal     M3.5  terminals

                   50                           Send data        3    SD                SD (orange)

                                                Receive data     2    RD                RD (white)

                                                Signal ground    5    SG                SG (gray)

                                                Request to send  7    RS

                                                Clear to send    8    CS

                                                Data set ready   6    DR

                                 Data terminal ready             4    ER

Specifications

■ Ratings

                       Item                                      K3SC-10 100 to 240 VAC              K3SC-10 24 VAC/VDC

Supply voltage                                  100 to 240 VAC 50/60 Hz                              24 VAC 50/60 Hz, 24 VDC

Operating voltage range                         85% to 110% of power supply voltage

Power consumption                               5 VA max.                                            3 VA max./3 W max.

Master/slave device communications format       Master Device             Slave Device

(Select one of the formats listed on the right  RS-232C or USB            RS-485, half duplex

using the DIP switch.)                          RS-232C or USB            RS-422, full duplex

                                                USB                       RS-232C, full duplex

Communications method                           Start-stop synchronization

Ambient operating       RS-232C                 –10 to 55 °C (with no icing)

temperature             USB                     0 to 55 °C (with no icing)

Ambient operating humidity                      25% to 85% (with no condensation)

Ambient storage temperature                     –20 to 65 °C

                                                                                                                                      2
                                                                                                                                                               K3SC

■ Characteristics

                              Item                                                                         Specification

               RS-232C        Maximum transmission       15 m

               interface      distance

Master device  (See note 1.)  Maximum number of          1 Unit

                              connectable Units

               USB interface  Maximum transmission       5 m; hub delay time + cable delay time ≤ 70 ns

               (See note 2.)  distance

                              Maximum number of          1 Unit

                              connectable Units

                              USB standard               V1.1

               RS-485         Maximum transmission       500 m

Slave device   interface      distance

                              Maximum number of          31 Units (for multi-drop connection)

                              connectable Units

               RS-422         Maximum transmission       500 m

               interface      distance

                              Maximum number of          1 Unit

                              connectable Units

Baud rate                                                1,200/2,400/4,800/9,600/19,200/38,400 (bps)

                                                         Default setting: 9,600

Data length                                              7/8 bits

                                                         Default setting: 7

Stop bit length                                          1/2 bits

                                                         Default setting: 2

Communications parity                                    None/even/odd

                                                         Default setting: Even

Echoback selection                                       Echoback: With/without

                                                         Default setting: Without

Selection switch response delay                          Approx. 30 ms

Insulation resistance                                    20 MΩ min. measured at 500 VDC between the following:

                                                         External terminals ↔ casing

                                                         RS-232C terminals and USB port ↔ RS-422/485 terminals ↔ power supply terminals

                              Isolation        Communi-  Phototransistor coupler

                              method           cations

                                               Power     Isolating transformer

                                               supply

Dielectric strength                                      1,500 VAC for 1 minute measured between the following:

                                                         External terminals ↔ casing

                                                         RS-232C terminals, USB port, RS-422 terminals, and RS-485 terminals ↔ power supply terminals

                                                         500 VAC for 1 minute measured between the following:

                                                         RS-232C terminals and USB port ↔ RS-422 terminals and RS-485 terminals

Noise immunity                                           AC power supply terminals, normal/common mode: ±1,500 V

                                                         AC/DC power supply terminals, normal mode: ±480 V; common mode: ±1,500 V

                                                         Square wave with 1-ns rising edge ±1 μs, ±100 ns

Vibration resistance          Malfunction                10 to 55 Hz, 0.5-mm single amplitude for 10 minutes each in X, Y, and Z directions

                              Destruction                10 to 55 Hz, 0.75-mm single amplitude for 2 hours each in X, Y, and Z directions

Shock resistance              Malfunction                98 m/s2 3 times each in X, Y, and Z directions

                              Destruction                294 m/s2 3 times each in X, Y, and Z directions

Weight                                                   Approx. 150 g

Degree of protection          Front panel operation      Conforms to IEC standards, equivalent to IP20 (when terminal cover mounted)

(See note 3.)                 parts

                              Terminals                  Equivalent to VDE 0106/100 (when terminal cover mounted)

EMC                                                      (EMI)                                 EN61326+A1                 Industry

                                                         Emission  Enclosure:                  CISPR 11 Group    1  class A: CISRP16-1/-2

                                                         Emission  AC Mains:                   CISPR 11 Group    1  class A: CISRP16-1/-2

                                                         (EMS)                                 EN61326+A1                 Industry

                                                         Immunity  ESD:                        EN61000-4-2:               4 kV contact discharge (level 2)

                                                                                                                          8 kV air discharge (level 3)

                                                         Immunity  RF-interference:            EN61000-4-3:               10 V/m (amplitude-modulated,

                                                                                                                          80 MHz to 1 GHz) (level 3)

                                                         Immunity  Fast Transient Noise:       EN61000-4-4:               2 kV (power line) (level 3)

                                                         Immunity  Burst Noise:                                           1 kV line to line (I/O signal line)

                                                         Immunity  Surge:                      EN61000-4-5:               1 kV line to line

                                                                                                                          2 kV line to ground (power line)

                                                         Immunity  Conducted Disturbance       EN61000-4-6:               3 V (0.15 to 80 MHz) (level 2)

                                                         Immunity  Voltage Dip/Interrupting    EN61000-4-11:              0.5 cycles, 0, 180°, 100% (rated     voltage)

Approved standards                                       UL508,

                                                         Conforms to EN61326+A1, EN61010-1 (IEC61010-1)

Memory protection                                        No protective functions (Communications data is not protected for power interruptions during communications.)

Note: 1.           With RS-232C communications, free-run mode is supported for SD and RD but not for any other signal lines.

               2.  To use USB communications, the USB driver for the K3SC must be downloaded from the OMRON web site.

                   http://www.fa.omron.co.jp/

               3.  The enclosure ratings do not apply when USB is used.

               4.  The CE marking does not apply when the K3SC is used for USB.

                                                                                                                                                                         3
                                                                                                                                           K3SC

Connections

■ Terminal Specifications

Be sure to check the input and output specifications for the   signal pins of connected devices before connecting the terminals.

        Function               Terminal                  Name       Signal direction                                          Explanation

                               number

For connecting the         1 and 4         PWR                      ---                     The input power supply specifications vary with the model.

operating power supply                                                                      A 100 to 240-VAC model and a 24-VAC/VDC (no-polarity) mod-

                                                                                            el are available.

Connection terminals for   3               SG                       ---                     Connect to signal ground.

RS-232C                    5               SD                       Input                   Receives data from SD of the master device.

communications with        6               RD                       Output                  Sends data to RD of the master device.

master device

(DIP switch pin 8: OFF)

Used for RS-485            8               RDA(−)                   Input/output            SD and RD for RS-485 (cold side)

communications with slave  9               SDA(−)                                           Terminals 8 and 9 are connected internally when pin 9 of the

device                                                                                      DIP switch is set to OFF.

(DIP switch pin 9: OFF)    11              RDB(+)                   Input/output            SD and RD for RS-485 (hot side)

                           12              SDB(+)                                           Terminals 11 and 12 are connected internally when pin 9 of the

                                                                                            DIP switch is set to OFF.

Used for RS-422            7               SG                       ---                     Connect to signal ground.

communications with slave  8               RDA(−)                   Input                   Receives RS-422 data and outputs it to the master side.

device                     9               SDA(−)                   Output                  Converts data received via RS-232C from the master device to

(DIP switch pin 9: ON)                                                                      RS-422 data and outputs the data.

                           11              RDB(+)                   Input                   Receives RS-422 data and outputs it to the master side.

                           12              SDB(+)                   Output                  Converts data received via RS-232C from the master device to

                                                                                            RS-422 data and outputs the data.

Note: Terminals 2 and 10 are not used.

■ Internal Configuration (Block Diagram)

                                           DIP switch                    Status                     Power

                                                                         indicator                  indicator

                                           Switch input                          Indicator control                            Power

                                                                                                                              supply

                                           Serial                          Serial     PHC

RS-232C                        RS-232C     communi-                        communi-                            RS-485 driver               RS-422 or

                               driver      cations                         cations                                                         RS-485

                                                                                      PHC

                                                               CPU         RS-485 enabling

                                                                           control

                                                                                      PHC

USB                            USB         USB control

                               controller

                                                                                     Insulation

                                                                                                                                                            4
                                                                                                                                                                                           K3SC

■ External Connections

RS-485 Connection                                                                                        RS-422 Connection

                          K3SC                        Slave device side                                                                                   Slave device side

                                                      RS-485                                                                                              RS-422

                                                                                                                                        K3SC                                 Abbreviation

                    7     8      9                        (−)                                                                                                                    SG

                                       (See note 1.)

                    10    11     12                       (+)                                                                                                                   SDA (−)

                                       (See note 1.)                                                                                                                            SDB (+)

                                                      Master device side                                                            7   8        9                              RDA (−)

                                                      RS-232C                                                                       SG  RDA (−)  SDA (−)                        RDB (+)

                                                                                                                                    10  11       12

                                                      Abbre-   Pin number (for 9-pin                                                    RDB (+)  SDB (+)

                                                      viation  computer connector)                                                                        Master device side

                                                      SD                  3                                                                               RS-232C

                                                      RD                  2                                                                               Abbre-                     Pin number (for 9-pin

                                                      SG                  5                                                                               viation                    computer connector)

                    4     5      6                    RS                  7                                                                                                  SD            3

Input power supply        SD     RD                   CS                  8                                                                                                  RD            2

(See note 2.)       1     2      3                    DR                  6                                                                                                  SG            5

                                 SG                   ER                  4                                                         4   5        6                           RS            7

Note: 1.  If RS-485 is selected as the communications method (i.e.,                                      Input power supply             SD       RD                          CS            8

                                                                                                         (See note.)                1   2        3                           DR            6

          pin 9 of the DIP switch is set to OFF), terminals 8 and 9, and                                                                         SG                          ER            4

          terminals 11 and 12 are connected internally.

2.        Either a 100 to 240-VAC or 24-VAC/VDC (no polarity) input                                      Note: Either a 100 to 240-VAC or                 24-VAC/VDC (no polarity) input

          power supply is used.                                                                          power supply is used.

Connecting an RS-232C or USB Master                                                               Device to an RS-422/485                                 Slave Device

First set the same communications conditions (baud rate, stop bits, data length, and parity) for the master device, the Interface Converter, and

slave devices.

                                                                                                                                                          Devices connected

                                       If the communications interface format                                                                             via RS-485 (example)

                                       for the master device is RS-232C, set

                                       pin 8 of the DIP switch to OFF.

                                                                                                                      AL1

                                                                                                                      AL2

                                                                                                                      HB

                                                                                                                      OT1  STP

                                                                                                                      OT2  CMW

                                                                         Wire with                 K3SC

          Computer                                                       stranded wires.

                          Note:  To allow connection using a commercially available cable with an                                       In addition to the required communications

                                 RS-232C D-sub connector, a connection adapter (D-sub, 9-pin) is                                        conditions, set the communications number.

                                 available. (Order separately; model number: K32-23209.)                              Note:     With RS-485 communications, connect a terminating resis-

                                                                                                                                tance (120 Ω, 1/2 W recommended) to both ends of the com-

                                                                                                                                munications path.

                                 Cable with RS-232C D-sub connector            K32-23209

Note: 1.  1-to-N connection via OMRON NT Link communications is not supported.

2.        If the communications interface format for the master device is USB, obtain a commercially available USB cable and download the USB

          driver for the K3SC from the OMRON web site.

Connecting a USB Master Device to an RS-232C Slave Device

First set the same communications conditions (baud rate, stop bits, data length, and parity) for the master device, the Interface Converter, and

slave devices.

Note: There is no isolation between the USB and RS-232C sides.

                                              Set pin 8 of the DIP switch to ON to        select

                                              the following communications format:

                                              Master device: USB; Slave device: RS-232C

                                                                                                                                        RS-232C

                                                      USB connection

                                       Note:  Use a commercially available USB cable.                    K3SC

                Computer                                                                                                                                  Measuring/testing device

Note:     The USB driver is available                                                                    Wire with stranded wires.

          from the OMRON web site.

          http://www.fa.omron.co.jp/

                                                                                                                                                                                                            5
                                                                                                                                                                    K3SC

Operation

■ Communications Settings Switch

Use this switch to   set the  communications conditions for                   the K3SC to     those used by  connected devices.

Setting                       Baud rate                                          Data length  Stop bits            Parity             Configuration                 Echoback

             1,200   2,400    4,800        9,600          19,200      38,400     7      8     2    1         Even  Odd     None   Master:       Master:             OFF          ON

             bps     bps      bps          bps            bps         bps                                                         USB           RS-232C             (with-    (with)

ON↔OFF                                                                                                                                          or USB              out)

                                                                                                                                                (See note.)

                                                                                                                                  Slave:        Slave:  Slave:

                                                                                                                                  RS-           RS-     RS-

                                                                                                                                  232C          485            422

1            ON      OFF      ON           OFF            ON         OFF

2            OFF     ON       ON           OFF            OFF        ON

3            OFF     OFF      OFF          OFF            ON         ON

4                                                                             OFF       ON

5                                                                                             OFF  ON

6                                                                                                            OFF   ON      OFF

7                                                                                                            OFF   OFF     ON

8                                                                                                                                 ON            OFF

9                                                                                                                                               OFF     ON

0                                                                                                                                                                   OFF       ON

Note: 1.  All pins are factory-set to OFF.

   2.     When using RS-422 full-duplex communications, turn OFF pin 0.

   3.     When using the communications configuration with RS-232C or USB set for the master device and RS-422 or RS-485 set for the slave

          device, use either RS-232C or USB (but not both) on the master device side.

Nomenclature

       Terminal Cover                                                                         K3SC without Terminal Cover

                                                                                                                        Communications Status Indicators

                                                                                                                        Light (yellow) during communications.

                                                                                                                        • RS-232C/USB ↔ RS-422/485:

                                                                                                                           RD: Lights when receiving RS-422/485 communications.

                                     Power Indicator                                                                       SD: Lights when sending RS-422/485 communications.

                                     Lights (green) when                                                                • USB ↔ RS-232C:

                                     power is supplied.                                                                    RD: Lights when receiving RS-232C communications.

                                                                                                                           SD: Lights when sending RS-232C communications.

                                     Communications Setting Switch

                                     Used to set the communications conditions for                                      USB Port

                                     connected devices.                                                                 Port for USB connections. Use this port

                                                                                                                        if the master device is a USB device.

                                                              Communications Setting Switch

                                                               Switch         Setting

                                                                  1

                                                                  2      Baud rate

                                                                  3                                                        M3.5 Terminal Screw

                                                                  4

                                                                  5      Data length

Note:     Cover the terminals to prevent electric shock.          6

                                                                  7      Parity

   Caution:  Be sure to use the K3SC-10 with                      8      Master device

             the terminal cover mounted                           9      Slave device

             when using in machinery that                         10

             must conform to EN/IEC stan-                                Echoback

             dards.

                                                                                                                                                                                      6
                                                                                   K3SC

Dimensions

K3SC-10

                                   7

                                             Mounting Hole Dimensions

                                             (For Direct Mounting)

                                             Two, M4 or 4.3-dia. holes

                         75

                                      80     72±0.3

            30  3  23.5      51.5

                         78           Note:  DIN track mounting is also possible.

                                                                                         7
                                                                                                                                   K3SC

Safety Precautions

                          !CAUTION

Do not touch any of the terminals while power is being

supplied. Doing so may result in electric shock.

Do not allow metal objects or wire cuttings to enter the

product. Doing so may result in electric shock, fire, or

malfunction.

Do not attempt to disassemble, repair, or modify the

product. Any attempt to do so may result in malfunction,

fire, or electric shock.

Make sure that the power supply voltage is within the

specified range. Otherwise, damage or burning may

result.

Be sure to tighten the terminal screws to the specified

torque. Loose screws may result in burning or

malfunction. The recommended tightening torque is

0.78 N·m.

■ General Precautions

• Do not mount the product in the following places:

1.  Locations subject to shock or vibration

2.  Outdoor locations or locations subject to direct sunlight, wind, or

    rain.

3.  Locations subject to temperatures or humidity outside the

    specified ranges

4.  Locations subject to condensation or icing

5.  Locations subject to large amounts of dust

6.  Locations subject to flammable gases or objects

7.  Locations subject to corrosive gases (in particular sulfide or

    ammonia gases)

• Be sure to check power supply specifications, terminal numbers,

   and polarities before performing wiring.

• Turn OFF the power supply before performing installation or wiring.

• Turn OFF the power supply before removing the terminal cover.

   Accidentally touching the terminals may result in electric shock.

• Do not connect anything to unused terminals.

■ Correct Use

•  Perform wiring with crimp terminals that are suitable for M3.5

   screws.

•  Install the product as far away as possible from devices that

   generate strong high-frequency noise (e.g., high-frequency

   welders) or surges.

•  Do not pull on the USB cable. Doing so may cause the cable to

   come loose.

•  Almost all application programs run with the K3SC driver, which

   provides a virtual communications port for USB communications.

   Some application programs do not run, because this driver does

   not support all of the API functions.

                      ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                      To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                          In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                         8
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)

from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.                     ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.                                OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS

IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products.   This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given.             This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

•  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

•  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

   safety equipment, and installations subject to separate industry or government regulations.

•  Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the products may be changed without any notice.     When in doubt, special model numbers may be assigned to fix or

establish key specifications for your application on your request.  Please consult with your OMRON representative at any time to confirm actual

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent               the

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

                                                                                                                                                                         2009.7

                                                      In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/

                                                                                                          (c)Copyright OMRON Corporation 2009 All Right Reserved.