电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

K3HB-CNB 24VAC/VDC

器件型号:K3HB-CNB 24VAC/VDC
器件类别:热门应用    机电/工控/自动化   
文件大小:21008.01KB,共13页
厂商名称:All Sensors
标准:
下载文档

器件描述

控制器 npn Up/down counter 24vac/vdc

参数
制造商: Omron
产品种类: 控制器
RoHS:

K3HB-CNB 24VAC/VDC器件文档内容

Digital Indicators

K3HB Series (Pulse Input Series)

The K3HB Series has been made complete with
the addition of Digital Signal Input Models.

Easy recognition of judgment results using two-color
display that can be switched between red and green.

Equipped with a position meter for monitoring
operating status trends.

External event inputs allows using various
measurement and discrimination applications.

Series expanded to include DeviceNet models.
Short body with depth of only 95 mm (see note)

(from behind the front panel).
UL certification (Certification Mark License).
CE Marking conformance by third party assessment

body.
Water-resistant enclosure conforms to NEMA 4X

(equivalent to IP66).

Note: Depth of 97 mm for DeviceNet models.

         Refer to Common Precautions on page 30.

Features

Red-Green Display Allows Easy                                                50 kHz High-speed Pulse Measurement
Recognition of Judgment Results                                              (K3HB-R)

The measurement value display can be set to switch between red               Supports high-speed pulse measurement (up to 50 kHz) of rotary
and green in accordance with the status of comparative outputs. This         encoders or any ON/OFF pulse signal, which enables rotational
means that the status can be easily seen at a distance.                      measurement of objects rotating at high speeds.

Position Meter Enables Easy Monitoring of                                                 50 kHz
Operating Status Trends
                                                                             Note: No-voltage contacts of up to 30 Hz are supported.
The present value with respect to the measurement or display range
(full scale) can be viewed on a bar display. The operating status can        Measurement of Wide Range of Pulse
be grasped intuitively, allowing easy judgment of levels and threshold       Interval Times (K3HB-P)
values.
                                                                             Measures and displays the results of the pulse interval between two
HH Max                                   Position meter                      points. The pulse interval measurement range is broad, from 10 ms
H Min                                                                        to 3,200 s.
PB       CMW            HH H
         Hold   T LL L                                                                                10 ms to 3200 s
      L
L                                                                           High-speed Up/Down Counting Pulse
                                                                             Measurement (K3HB-C)
LL
                                                                             Perfect for high-speed measurement of rotary encoders or any
MAX/MIN  LEVEL  MODE          SHIFT  UP                                      ON/OFF pulse signals. Cumulative pulse input is 50 kHz, quadrature
                                                                             pulse inputs are 25 kHz, and up/down pulse inputs are 30 kHz.
Note: This function is different from the single-LED display of the K3HB-C.  Note: No-voltage contacts of up to 30 Hz are supported.

Short Body with Depth of Only 95 mm
(from Behind the Front Panel)

A short body of only 95 mm (see note) contributes to the
development of slimmer and smaller control panels and installations.

Depth: 95 mm (See note.)                    27%
                                           shorter
                                         than earlier
                                           models

      (The depth is 100 mm when mounted to the terminal cover.)
Note: Depth of DeviceNet models is 97 mm.

                                         Digital Indicators K3HB Series (Pulse Input Series)  1
Features

Many I/O Variations for Discrimination, Control, and Information Applications

Digital Indicators are used in a wide variety of applications, from an electronic measurement value display or equipment/device operating status
display to a host communications interface in monitoring and control systems. OMRON provides a complete lineup for a variety of input and control
output applications to meet all your application requirements.

Relay Outputs                                                                                                                                                                        Transistor Outputs

H and L: SPDT                            HH, H, L, and LL: SPST-NO PASS: SPDT                                                                                                        NPN or PNP

                    C1                             HH/OUT5 C1                                      B1                                                                                HH/OUT5 C1                  NPN       PNP
     H/OUT4 C2                                       H/OUT4 C2
                                                         COM C3                                    PASS/OUT3 B2                                                                      H/OUT4 C2
                    C3                               L/OUT2 C4
                    C4                             LL/OUT1 C5                                      B3                                                                                PASS/OUT3 C3
      L/OUT2 C5                                          COM C6
                    C6                                                                             N/C B4                                                                            L/OUT2 C4

                                                                                (CPB)              +                                                                                 LL/OUT1 C5
                                                                                 10 VDC 100 mA        B5 Sensor
                                                                                                            power                                                                                        COM C6
                                                                                (CPA)
                                                                                 12 VDC 80 mA      - B6 supply

Communications                                     Linear Output                                   DeviceNet                                                                                             BCD Output
Output
                                                   Voltage Output or Current Output                                                                                                                      NPN Open Collector
RS-232 or RS-485
                                                   0 to 20 mA DC/
RS-232C or                                         4 to 20 mA DC
RS-485                                             or
                                                   0 to 5 VDC/
                  Computer                         1 to 5 VDC/
                                                   0 to 10 VDC

Select a Comparative Output Pattern to                                                             Lineup Includes DeviceNet Models
Suit the Discrimination or Control                                                                 Enabling High-speed Data
Application                                                                                        Communications with PLCs without
                                                                                                   Special Programming
The output pattern for comparative outputs can be selected. In
  addition to high/low comparison with set values, output based on                                  DeviceNet compliance enables high-speed data transmission by
  level changes is also possible. (Use the type of output pattern                                    allocating setting and monitoring parameters in the I/O memory of
  appropriate for the application.)                                                                  the PLC. This capability greatly reduces labor spent in developing
                                                                                                     communications programs.
Comparative    Standard Outputs  Measurement                    Level Outputs  Measurement
set value HH                                                                        value
Comparative                      value            Comparative                             Higher
set value H
Comparative                      Higher           set value HH                            Lower
set value L                                       Comparative
Comparative                                                                         ON
set value LL                                      set value H                       OFF

Output HH                                          Comparative
Output H
Output PASS                       Lower            set value L
                                                   Comparative
Output L
                                                   set value LL
Output LL
                                  ON
                                  OFF Output HH

                                               Output H                                                                                                                                                          Ethernet

                                               Output PASS                                                       DeviceNet
                                               Output L                                                              Master

                                               Output LL

  Comparative   Zone Outputs      Measurement
  set value HH                         value
  Comparative                              Higher                                                                P
  set value H                                                                                                                                                                     H
  Comparative                               Lower
  set value L                                                                                                             Zero
  Comparative                         ON
  set value LL                        OFF                                                                        P
                                                                                                                                                                                  H
Output HH                                                                                                                                                                            K3HB
                                                                                                                          Zero                                                       Digital Indicators
Output H
Output PASS
Output L

Output LL

Note: The HH, H, L or LL outputs must be set in that order for the zone                                                                                                                                          DeviceNet
        outputs to output correctly.                                                                                                                                                                             Configurator
        (This is because the comparative set values and outputs for
        standard and level outputs are in a 1-to-1 relationship, whereas
        the meaning of zone outputs depends on the settings of all the
        comparative set values.)

2               Digital Indicators K3HB Series (Pulse Input Series)
Note: The applications provided in this catalog are intended as reference only. Do not attempt to use any of them in real systems without first
        confirming machine and device functions and safety. For applications that require safety, ensure that there is sufficient leeway in ratings and
        performances, install fail-safe measures, and take any other safety measures required by the application. In addition, contact your nearest
        OMRON representative and confirm specifications.

K3HB-series Product Lineup

K3HB-R Rotary Pulse Indicator (Page 4)

Performs High-speed Rotation Measurement Displaying Bread Baking Time
and Passing Time Measurement

                                                                        Oven                   Bread

Rotary Pulse Input Model: K3HB-R                                                                                 E6B

    K3HB-RNB: NPN input/voltage pulse input                                                    K3HB-R
    K3HB-RPB: PNP input                                                                        (F6: Passing time mode)
Input types: rpm/circumferential speed, absolute ratio, error ratio,

                  error, concentration, and passing time
Measurement range: 0.5 mHz to 50 kHz

K3HB-P Time Interval Indicator (Page 10)

Measuring Passing Speed between Two                                     Measuring Shot Speed
Points and Providing Time Judgments

                                                                                               Proximity sensor

Pulse Input Model: K3HB-P

K3HB-PNB: NPN input/voltage pulse input

    K3HB-PPB: PNP input                                                                        K3HB-P

Inputs: Passing speed, cycle, time difference, time band, measuring
            length, interval

Measurement ranges: Functions F1, F3, and F4: 10 ms to 3200 s

Function F2:                             20 ms to 3200 s

Functions F5 and F6: 0 to 4 gigacounts

K3HB-C Up/Down Counting Pulse Indicator (Page 15)

Measuring and Monitoring High-speed                                     Counting Workpieces
Up/Down Pulses

Up/down Counting Pulse Input Model: K3HB-C                                                     BCD To Programmable
                                                                                                         Controller

    K3HB-CNB: NPN input/voltage pulse input                             K3HB-C
                                                                        (F3: Cumulative mode)
Inputs: Individual inputs (up/down), quadrature inputs
            (up/down), cumulative input                                                        To large display unit

Response frequency: Individual inputs: 30 kHz, quadrature inputs:
                               25 kHz, cumulative input: 50 kHz

Note: No-voltage contacts of up to 30 Hz are supported.

Measurement ranges: Functions F1 and F2: 2 gigacounts

Function F3:                             0 to 4 gigacounts

                                         Digital Indicators K3HB Series (Pulse Input Series)                            3
   Rotary Pulse Indicator

   K3HB-R

Digital Rotary Pulse Meter Capable of 50 kHz
Measurements

Measures High-speed Pulses at 50 kHz.

  Provides high-speed pulse measurements up to 50 kHz of rotary
  encoder or ON/OFF pulse signals and can perform rotating
  measurement of high-speed rotating objects.
Note: No-voltage contacts of up to 30 Hz are supported.

Six Measurement Operations Including Rotation (rpm)/
Circumferential Speed, Ratio, and Cumulative

  One Rotary Pulse Meter has 6 rotary pulse measurement functions to
  support a variety of pulse measurement applications. Select the best
  function for your application from the following: rotation (rpm)/
  circumferential speed, absolute ratio, error ratio, error, flow rate ratio,
  and passing time.

         Refer to Common Precautions on page 30.

Model Number Structure

Model Number Legend

Base Units and Optional Boards can be ordered individually or as sets.

Base Units                             Base Units with Optional Boards

K3HB-R @                               K3HB-R@-@@@

   15                                                               1 234 5

1. Input Sensor Codes                  2. Sensor Power Supply/Output Type Codes
    NB: NPN input/voltage pulse input
    PB: PNP input                      None: None

5. Supply Voltage                      CPA: Relay output (PASS: SPDT) + Sensor power supply
    100-240 VAC:100 to 240 VAC                    (12 VDC10%, 80 mA) (See note 1.)
    24 VAC/VDC: 24 VAC/VDC
                                       L1A: Linear current output (DC0(4)-20 mA) + Sensor power supply
Optional Board                                    (12 VDC10%, 80 mA) (See note 2.)

Sensor Power Supply/Output Boards      L2A: Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
                                                  (12 VDC10%, 80 mA) (See note 2.)
K33-@
                                       A:                           Sensor power supply (12 VDC 10%, 80 mA)
           2
                                       FLK1A: Communications (RS-232C) + Sensor power supply
Relay/Transistor Output Boards                    (12 VDC10%, 80 mA) (See note 2.)

K34-@                                  FLK3A: Communications (RS-485) + Sensor power supply
                                                  (12 VDC10%, 80 mA) (See note 2.)
           3
                                       3. Relay/Transistor Output Type Codes
Event Input Boards
                                       None: None
K35-@
                                       C1: Relay contact (H/L: SPDT each)
           4
                                       C2: Relay contact (HH/H/LL/L: SPST-NO each)

                                       T1: Transistor (NPN open collector: HH/H/PASS/L/LL)

                                       T2: Transistor (PNP open collector: HH/H/PASS/L/LL)

                                       BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)

                                       DRT: DeviceNet (See note 2.)

                                       4. Event input Type Codes

                                       None: None

                                       1: 5 points (M3 terminal blocks) NPN open collector
                                       2: 8 points (10-pin MIL connector) NPN open collector

                                       3: 5 points (M3 terminal blocks) PNP open collector

                                       4: 8 points (10-pin MIL connector) PNP open collector

Note: 1. CPA can be combined with relay outputs only.

        2. Only one of the following can be used by each Digital Indicator:
             RS-232C/RS-485 communications, BCD communications, or DeviceNet communications.

Accessories (Sold Separately)

   K32-DICN: Special Cable (for event inputs with 8-pin connector)
   K32-BCD: Special BCD Output Cable

4  Rotary Pulse Indicator K3HB-R
Specifications

Ratings

Supply voltage                     100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC

Allowable power supply voltage     85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
range
                                   100 to 240 VAC: 18 VA max. (max. load)
Power consumption                  24 VAC/DC: 11 VA/7 W max. (max. load)
(See note 1.)
                                   DeviceNet power supply: 50 mA max. (24 VDC)
Current consumption
                                   No-voltage contact, voltage pulse, open collector
Input
                                   12 VDC 10%, 80 mA (models with external power supply only)
External power supply
                                   NPN open collector or no-voltage contact signal
Event inputs Startup compen-       ON residual voltage: 2 V max.
(See note 2.) sation timer input   ON current at 0 : 4 mA max.
                                   Max. applied voltage: 30 VDC max.
                Hold input         OFF leakage current: 0.1 mA max.

                Reset input        250 VAC, 30 VDC, 5 A (resistive load)
                                   Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
                Bank input
                                   Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max.
Output ratings Relay output        Linear output 0 to 20 mA DC, 4 to 20 mA:

(depends on                            Load: 500  max, Resolution: Approx. 10,000, Output error: 0.5% FS
                                   Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
the model)      Transistor output
                                       Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS
                Linear output      (1 V or less: 0.15 V; not output for 0 V or less)

Display method                     Negative LCD (backlit LED) display
                                   7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))
Main functions
                                   Scaling function, measurement operation selection, averaging, previous average value comparison, output hystere-
Ambient operating temperature      sis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank se-
Ambient operating humidity         lection, display refresh period, maximum/minimum hold, reset
Storage temperature
Altitude                           -10 to 55C (with no icing or condensation)
Accessories                        25% to 85%

                                   -25 to 65C (with no icing or condensation)
                                   2,000 m max.

                                   Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De-
                                   viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.)

Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
            attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is
            recommended.

        2. PNP input types are also available.

        3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
            Thin Cables.

                                   Rotary Pulse Indicator K3HB-R  5
Characteristics

Display range                      -19,999 to 99,999
Measurement accuracy
(at 235C)                        Functions F1, F6: 0.006% rgd 1 digit (for voltage pulse/open collector sensors)
Measurement range                  Functions F2 to F5: 0.02% rgd 1 digit (for voltage pulse/open collector sensors)
Input signals
                                   Functions F1 to F6: 0.5 mHz to 50 kHz (for voltage pulse/open collector sensors)
Connectable sensors
                                   No-voltage contact (30-Hz max. with ON/OFF pulse width of 15 ms min.)
Comparative output response        Voltage pulse (50-KHz max. with ON/OFF pulse width of 9 s min.; ON voltage: 4.5 to 30 V;
time (transistor output)           OFF voltage: -30 to 2 V; input impedance: 10 k)
Linear output response time        Open collector (50-KHz max. with ON/OFF pulse width of 9 s min.)

Insulation resistance              ON residual voltage: 3 V max.
Dielectric strength
Noise immunity                     OFF leakage current: 1.5 mA max.

                                   Load current:      Must have a switching capacity of 20 mA or higher.

                                                      Must be able to properly switch load currents of 5 mA or less.

                                   Functions F1 to F6: 100 ms max. (time until the comparative output is made when there is a forced sudden
                                   change in the input signal from 15% to 95% or 95% to 15%.)

                                   Functions F1 to F6: 110 ms max. (time until the final analog output value is reached when there is a forced
                                   sudden change in the input signal from 15% to 95% or 95% to 15%.)

                                   20 M min. (at 500 VDC)

                                   2,300 VAC for 1 min between external terminals and case

                                   100 to 240 VAC models:
                                       1,500 V at power supply terminals in normal or common mode
                                       (waveform with 1-ns rising edge and pulse width of 1 s/100 ns)

                                   24 VAC/VDC models:
                                       1,500 V at power supply terminals in normal or common mode
                                       (waveform with 1-ns rising edge and pulse width of 1 s/100 ns)

Vibration resistance               Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions

Shock resistance                   150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions

Weight                             Approx. 300 g (Base Unit only)

Degree of             Front panel  Conforms to NEMA 4X for indoor use (equivalent to IP66)
protection            Rear case
                                   IP20

                      Terminals    IP00 + finger protection (VDE0106/100)

Memory protection                  EEPROM (non-volatile memory)
                                   Number of rewrites: 100,000

Applicable standards               UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
                                   EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
                                   EN61326: 1997, A1: 1998, A2: 2001

EMC                                EMI: EN61326+A1 industrial applications

                                   Electromagnetic radiation interference
                                       CISPR 11 Group 1, Class A: CISPRL16-1/-2

                                   Terminal interference voltage
                                       CISPR 11 Group 1, Class A: CISPRL16-1/-2

                                   EMS: EN61326+A1 industrial applications

                                   Electrostatic Discharge Immunity
                                       EN61000-4-2: 4 kV (contact), 8 kV (in air)

                                   Radiated Electromagnetic Field Immunity
                                       EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)

                                   Electrical Fast Transient/Burst Immunity
                                       EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)

                                   Surge Immunity
                                       EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)

                                   Conducted Disturbance Immunity
                                       EN61000-4-6: 3 V (0.15 to 80 MHz)

                                   Power Frequency Magnetic Immunity
                                       EN61000-4-8: 30 A/m (50 Hz) continuous time

                                   Voltage Dips and Interruptions Immunity
                                       EN61000-4-11: 0.5 cycle, 0/180, 100% (rated voltage)

6           Rotary Pulse Indicator K3HB-R
Operation

Functions (Operating Modes)

F1 to F6

Functions F1 to F6 provide rpm/circumferential speed and other calculation displays by measuring continuous pulses (frequencies).
Example

                  Length of               F1:         Displays rotation (rpm) or circumferential speed for one input.
             processing stage

                                          F2 to F5: Displays the calculation result for two rotation (rpm) speeds.

                                          F6:         Displays the passing time calculated from the circumferential speed and the length

                                                      of the processing stage for one input.

    Function name        Function No.     The basic principle used by the Digital Indicator to calculate the rotation speed (rpm) display is
Rpm/circumferential    f1                 to count the ON/OFF time (T) for input sensor or other device inputs using the internal system
speed                                     clock, and then automatically calculate the frequency. This frequency (f) is multiplied by 60 and
Absolute ratio         f2                 displayed as the rotation (rpm) speed.
Error ratio            f3
Rotational difference  f4                 Input sensor or other input pulse ON/OFF time (T) =         T  Frequency (f) =           1
Flow rate ratio        f5                                                                                                          T
Passing time           f6
                                           Rotation speed (rpm) = f 60
                                           Circumferential speed = Roll circumference Rotation speed (rpm)
                                           Passing time= Length of processing stage

                                                                    Circumferential speed
                                          These calculations are automatically made internally and displayed whenever any input pulse
                                          is received.

Function                       Operation                              Operation image (application)

F1           Measures frequency for input A and displays the          Measuring roller winding speed  Measuring motor speed
Rpm/cir-     rotation (rpm) or circumferential speed proportional to                                  (for product testing)
cumferen-    the input frequency.
tial speed/
Instanta-     Calculation      Display  Prescale value ()                                                                               H
neous                            unit
flowrate     Rotation                             1/N                                                                                   PASS
             speed               rpm            1/60 N
                                                                                                                                        L
                                  rps                                                                                              OK/NG
                                                                                                                                   judgment
             Frequency (of       Hz           1/60
             input pulse)       kHz        1/60000
                               mm/s     1000 d/60 N
             Circumferenti     cm/s     100 d/60 N
             al speed           m/s        d/60 N
                               m/min
                                             d/N

             Instantaneous     km/h                 0.06 d/N
             flowrate          l/min
                                        Check the output
                                l/h     specifications of the input
                                        device and calculate the
                                        prescale value from the
                                        following equation:

                                        Display value D = a 60

                                       

             N = Pulses per rotation
             d = Circumferential length per rotation

                                                                      Rotary Pulse Indicator K3HB-R                                           7
Function                            Operation                                                                Operation image (application)
                                                                                 Measuring the speed ratio between two rollers
F2           Multiples  input  B  divided  by  input  A  (  B  )  by  100  and
Absolute                                                    A                                                                                                                      HH
ratio                                                                                                                                                                              H
             displays the ratio as a percentage (%).                                                                                                                               PASS
                                                                                                                                                                                   L
                Display unit: %                                                                                                                                                    LL
                                                                                                                                                                              Warning

F3           Multiplies the error between input A and input B                    Measuring the line speed error ratio between two conveyors
Error ratio
             (B  -1)  by  100  and  displays   the  ratio   as    a  percentage
              A

             (%).

                Display unit: %                                                                                                                         Communications
                                                                                                                                                        output
                                                                                                                                                                                         To computer
                                                                                                                                                        (remote monitoring)

F4           Displays the difference between input A and input B                 Measuring the rotation (rpm)/circumferential speed error (absolute error)
                                                                                 between two conveyors
Rotational (B - A) as the rotation (rpm) speed error or
                                                                                                                                                                                      HH
difference circumferential speed error.                                                                                                                                               H
                                                                                                                                                                                      PASS
             Display unit:                                                                                                                                                         L
                                                                                                                                                                                     LL
                rpm, rps, rph,     m/s                                                                                                                                          Warning
                Hz, kHz, mm/s,         
                m/min, km/h            
                                         
             l/min, l/h, etc.         

F5           Displays the flow rate ratio of B from inputs A and B               Monitoring liquid mixture flow rate ratio
Flow rate    ( B ) as a ratio (%).
ratio         A+B                                                                                                                        Linear output

               Display unit: %

                                                                                                                                                        Recording meter

F6           Passing time (s) = 1/a                                             Displaying the passing time for a conveyor line
Passing
time         a: Input frequency (Hz)
             Set the prescale value for the desired display unit using
             the following table for reference.

                 Calculation Display unit Prescale value ()

                Passing time               s                    L/(d/N)          Distance                                                                   H

             N = Pulses per rotation                                                                                                                        PASS
             d = Circumferential length per rotation (m)
             L = Length of process (m)                                                                                                                      L
                                                                                                                                                        Warning

                                                                                                                                                         output

8            Rotary Pulse Indicator K3HB-R
What Is Prescaling?                                                   What Is the Auto-zero Function?

To make calculations using the input pulse to display rotation (rpm)      (Set this function before using the Digital Indicator.)
or circumferential speed, the number of pulses per rotation or the
length of the circumference must be multiplied by a certain           If a function f1 to f6 is set, the frequency can be force-set to zero if
coefficient. This coefficient is called the prescale value.
                                                                      there is no input pulse for a set period. This period is called the auto-
                                    K3HB-R                            zero time. Set the auto-zero time to slightly longer than the longest
                                                                      input pulse interval. (The display will not easily return to zero if the
                         Proximity                                    auto-zero time is too long or left at the default setting.)
                           sensor
                                                                      Time Unit Settings
Rotation speed (rpm) = f 60 a
    f: Input pulse frequency (No. of pulses per second)                        Setting                            Meaning
    a: Prescale value                                                 scal                  Prescale value menu setting
                                                                      min                   Minute display
If there are 5 pulses per rotation, then                              h.mm.ss               h.mm.ss display
    a = 1/5 (= 0.2 = 2 10-1)                                        mm.ss.d               mm.ss.d display (d = tenths of a second)
    and an accurate rotation speed (rpm) can be calculated.
                                                                      Note: Time unit can be set only when passing time (F6) is selected.
The actual setting is X = 2.0000 (mantissa) and Y = 10-1 (exponent).
                                                                      Input Type Setting

                                                                                        NO: Voltage pulse high NC: Voltage pulse low

                                                                      No-contact or     00  01
                                                                      voltage pulse
                                                                      input             10  11

                                                                      Contact

                                                                      Note: Set to 10 or 11 when there is a large variation in the display.

                                                                              The largest measurement range is 30 Hz.

                                                                      Rotary Pulse Indicator K3HB-R                                   9
Timer Interval Indicator

K3HB-P

Digital Time Interval Meter for Measuring
Passing Speed, Time, or Cycle between Two
Points.

Measures Wide Range of Pulse Interval Times

  Measures, calculates, and displays pulse intervals between two
  points. Wide range for pulse interval measurements, from 10 ms to
  3,200 s, max.

Six Measurement Operations, Including Passing Speed, Time,
and Cycle Measurement between Two Points

  One Digital Time Interval Meter has six measurement functions, to
  support a variety of pulse interval measurement applications. Select
  the best function for your application from the following: Passing
  speed, cycle, time difference, time band, measuring length, and
  interval.

         Refer to Common Precautions on page 30.

Model Number Structure

Model Number Legend

Base Units and Optional Boards can be ordered individually or as sets.

Base Units                             Base Units with Optional Boards

K3HB-P @                               K3HB-P@-@@@

    15                                                                  1 234 5

1. Input Sensor Codes                  2. Sensor Power Supply/Output Type Codes
    NB: NPN input/voltage pulse input
    PB: PNP input                      None: None

5. Supply Voltage                      CPA: Relay output (PASS: SPDT) + Sensor power supply
    100-240 VAC: 100 to 240 VAC                   (12 VDC10%, 80 mA) (See note 1.)
    24 VAC/VDC: 24 VAC/VDC
                                       L1A: Linear current output (DC0(4)-20 mA) + Sensor power supply
Optional Board                                    (12 VDC10%, 80 mA) (See note 2.)

Sensor Power Supply/Output Boards      L2A: Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
                                                  (12 VDC10%, 80 mA) (See note 2.)
K33-@
                                       A:                               Sensor power supply (12 VDC 10%, 80 mA)
           2
                                       FLK1A: Communications (RS-232C) + Sensor power supply
Relay/Transistor Output Boards                    (12 VDC10%, 80 mA) (See note 2.)

K34-@                                  FLK3A: Communications (RS-485) + Sensor power supply
                                                  (12 VDC10%, 80 mA) (See note 2.)
           3
                                       3. Relay/Transistor Output Type Codes
Event Input Boards
                                       None: None
K35-@
                                       C1: Relay contact (H/L: SPDT each)
           4
                                       C2: Relay contact (HH/H/LL/L: SPST-NO each)

                                       T1: Transistor (NPN open collector: HH/H/PASS/L/LL)

                                       T2: Transistor (PNP open collector: HH/H/PASS/L/LL)

                                       BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)

                                       DRT: DeviceNet (See note 2.)

                                       4. Event input Type Codes

                                       None: None

                                       1: 5 points (M3 terminal blocks) NPN open collector

                                       2: 8 points (10-pin MIL connector) NPN open collector

                                       3: 5 points (M3 terminal blocks) PNP open collector

                                       4: 8 points (10-pin MIL connector) PNP open collector

Note: 1. CPA can be combined with relay outputs only.

        2. Only one of the following can be used by each Digital Indicator:
             RS-232C/RS-485 communications, a linear output, or DeviceNet communications.

Accessories (Sold Separately)

K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable

10  Timer Interval Indicator K3HB-P
Specifications

Ratings

Supply voltage                     100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC

Allowable power supply voltage     85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
range
                                   100 to 240 VAC: 18 VA max. (max. load)
Power consumption                  24 VAC/DC: 11 VA/7 W max. (max. load)
(See note 1.)
                                   DeviceNet power supply: 50 mA max. (24 VDC)
Current consumption
                                   No-voltage, voltage pulse, open collector
Input
                                   12 VDC 10%, 80 mA (for models with external power supplies only)
External power supply
                                   NPN open collector or no-voltage contact signal
Event inputs Hold input            ON residual voltage: 2 V max.
(See note 2.) Reset input          ON current at 0 : 4 mA max.
                                   Max. applied voltage: 30 VDC max.
                       Bank input  OFF leakage current: 0.1 mA max.

Output ratings Relay output        250 VAC, 30 VDC, 5 A (resistive load)
                                   Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
(depends on
                                   Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max.
the model)   Transistor output
                                   Linear output 0 to 20 mA DC, 4 to 20 mA:
             Linear output             Load: 500  max, Resolution: Approx. 10,000, Output error: 0.5% FS

Display method                     Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
                                       Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS
Main functions
                                   (1 V or less: 0.15 V; not output for 0 V or less)
Ambient operating temperature
Ambient operating humidity         Negative LCD (backlit LED) display
Storage temperature                7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))
Altitude
Accessories                        Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, teaching, dis-
                                   play value selection, display color selection, key protection, bank selection, display refresh period, maximum/mini-
                                   mum hold, reset

                                   -10 to 55C (with no icing or condensation)

                                   25% to 85%

                                   -25 to 65C (with no icing or condensation)

                                   2,000 m max.

                                   Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De-
                                   viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.)

Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
            attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is
            recommended.

        2. PNP input types are also available.

        3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
            Thin Cables.

                                   Timer Interval Indicator K3HB-P  11
Characteristics

Display range                      -19,999 to 99,999
Measurement accuracy               0.08% rgd 1 digit (for voltage pulse/open collector sensors)
(at 235C)
Measurement range                  Functions F1, F3, and F4:10 ms to 3,200 s

Input signals                      Function F2:            20 ms to 3,200 s

                                   Functions F5 and F6: 0 to 4 gigacounts

                                    No-voltage contact (30 Hz max. with ON/OFF pulse width of 15 ms min.)

                                   Mode Input frequency ON/OFF ON voltage OFF voltage                          Input         Voltage pulse
                                                                                                                             Opencollector
                                                  range            pulse width                                 impedance

                                   F1 to F4 0 to 50 kHz           9 s min.     4.5 to 30 V -30 to 2 V 10 k

                                   F5, F6 0 to 30 kHz             16 s min.

                                   Mode Input frequency ON/OFF                  Note: The Digital Time Interval Meter
                                                                                        will malfunction if a pulse greater
                                                  range            pulse width          than the input frequency range is
                                                                                        input. SYSERR may appear on
                                   F1 to F4 0 to 50 kHz           9 s min.             the display.

                                   F5, F6 0 to 30 kHz             16 s min.

Connectable sensors                ON residual voltage: 3 V max.

Comparative output response        OFF leakage current: 1.5 mA max.
time (transistor output)
Linear output response time        Load current:  Must have a switching capacity of 20 mA or higher.

Insulation resistance                             Must be able to properly switch load currents of 5 mA or less.
Dielectric strength
Noise immunity                     2 ms max. (time until the comparative output is made when there is a forced sudden change in the input signal
                                   from 15% to 95% or 95% to 15%)

                                   10 ms max. (time until the final analog output value is reached when there is a forced sudden change in the
                                   input signal from 15% to 95% or 95% to 15%)

                                   20 M min. (at 500 VDC)

                                   2,300 VAC for 1 min between external terminals and case

                                   100 to 240 VAC models:
                                       1,500 V at power supply terminals in normal or common mode
                                       (waveform with 1-ns rising edge and pulse width of 1 s/100 ns)

                                   24 VAC/VDC models:
                                       1,500 V at power supply terminals in normal or common mode
                                       (waveform with 1-ns rising edge and pulse width of 1 s/100 ns)

Vibration resistance               Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions

Shock resistance                   150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions

Weight                             Approx. 300 g (Base Unit only)

Degree of             Front panel  Conforms to NEMA 4X for indoor use (equivalent to IP66)
protection            Rear case
                                   IP20

                      Terminals    IP00 + finger protection (VDE0106/100)

Memory protection                  EEPROM (non-volatile memory)
                                   Number of rewrites: 100,000

Applicable standards               UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
                                   EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
                                   EN61326: 1997, A1: 1998, A2: 2001

EMC                                EMI: EN61326+A1 industrial applications

                                   Electromagnetic radiation interference
                                       CISPR 11 Group 1, Class A: CISPRL16-1/-2

                                   Terminal interference voltage
                                       CISPR 11 Group 1, Class A: CISPRL16-1/-2

                                   EMS: EN61326+A1 industrial applications

                                   Electrostatic Discharge Immunity
                                       EN61000-4-2: 4 kV (contact), 8 kV (in air)

                                   Radiated Electromagnetic Field Immunity
                                       EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4GHz to 2 GHz)

                                   Electrical Fast Transient/Burst Immunity
                                       EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)

                                   Surge Immunity
                                       EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)

                                   Conducted Disturbance Immunity
                                       EN61000-4-6: 3 V (0.15 to 80 MHz)

                                   Power Frequency Magnetic Immunity
                                       EN61000-4-8: 30 A/m (50 Hz) continuous time

                                   Voltage Dips and Interruptions Immunity
                                       EN61000-4-11: 0.5 cycle, 0/180, 100% (rated voltage)

12          Timer Interval Indicator K3HB-P
Operation

Functions (Operating Modes)

F1 to F6

These functions use the internal system clock to measure the time between pulses or the pulse ON time and then display time measurements or

a variety of other calculations.

                                                                Example: F1 Passing Speed                            The time (T) between input A pulse and input B pulse

Function name             Function No.                                                                               is measured by the internal system clock. If, for
                                                                                                                     example, the system clock measures 100,000 counts

Passing speed             f1                                                                                         during time T, then

Cycle                     f2                                        Input A                                          T = 1 system clock count (0.5 s) 100,000

Time difference           f3                                                                                         T = 0.05 s

Time band                 f4                                         Input B                                         F1 (the passing speed) is calculated internally

Measuring length          f5                                       Internal                       T                  using the formula    1   60 (m/min), and the
                                                                system clock                                      1                       T

Interval                  f6                                                           1                             display, in this example, would be         1    60=
                                                                                                                                                             0.05 s

                                                                                                                     1200 (m/min).

Function                               Operation                                                                             Operation image (application)
                                                                                                  Measuring workpiece passing speed between A and B
F1         The reciprocal of the time (T) from input A ON to input
Passing    B ON is multiplied by 60 and displayed.                                                                            A
speed                                                                                                        B

              Input A

              Input B

                          T1 TR   T2            TR      T3      TR      T4

              HOLD input

              Display            1 60                     1 60                        1 60
                                 T1                         T2                            T4

            Recovery time (TR) of 20 ms is required before
             starting the next measurement.

            Display unit:                  
           
                mm/s, m/s        etc.      
                m/min, km/h,               
                                             

F2         Measures and displays input A cycle (T).                                               Measuring feed cycles for parts
Cycle
              Input A     T1         T2         T3      T4          T5
F3
Time dif-     HOLD input
ference
              Display                 T1                    T2                            T5

                       Measurement range: 20 ms to 3,200 s

            Display unit:
                                
                ms, s, min.,     
                min.s.1/10 s     

           Displays the time (T) from input A ON to input B ON.                                   Measuring workpiece passing time        Measuring the length of a
                                                                                                  between A and B                         workpiece step by changing
                                                                                                                                          prescale values.
              Input A

              Input B

                          T1 TR          T2         TR      T3      TR           T4

              HOLD input                                                                                    A
                                                                                                  B

              Display

                                                T1                           T3               T4

                       Measurement range: 10 ms to 3,200 s

            Recovery time (TR) of 20 ms is required before
             starting the next measurement.

            Display unit:
                                
                ms, s, min.,     
                min.s.1/10 s     

                                                                                                                     Timer Interval Indicator K3HB-P                        13
Function                                 Operation                                             Operation image (application)

F4         Displays input A ON time (T).                                        Monitoring the ON time of a printing   Managing the valve release
                                                                                press                                  time
Time band

              Input A       T1              T2      TR            T3

                                   TR                                                                                                          Communications
                                                                                                                                               output
              HOLD input

              Display                               T1                   T3

                       Measurement range: 10 ms to 3,200 s

            Recovery time (TR) of 20 ms is required before
             starting the next measurement.

            Display unit:
                               
              ms, s, min.,     
              min.s.1/10 s     

F5         Displays the number of input A pulses while input B is               Measuring workpiece length
Measuring  ON.
length
                          123456                                  12345

              Input A                                                                                                  BCD
                                                                                                                                  To Programmable Controller

              Input B

              HOLD input

              Display                                       6            5

            Recovery time (TR) of 20 ms is required before
             starting the next measurement.

            Display unit:            
                                      
              mm,     cm,  m,  etc.   

F6         Displays the number of input A pulses from when input                Measuring slit intervals
Interval   B turns ON until input B turns ON again. Measurement
           is made every other time input B turns ON.
                                                                                                                                     H
                          1234              12 3 4                12         1                                                       PASS
                                                                                                                                     L
           Input A                                                                                                           OK judgment

           Input B

                                   TR                   TR

           HOLD input

           Display                       3                     4

                                                                                                                       12 3      12               12

            Recovery time (TR) of 20 ms is required before                                                       INA
                                                                                                                  INB
              starting the next measurement.                                                                  Display        TR            TR

            Display unit:            
                                     
              mm,     cm,  m,  etc.                                                                                            3             2

What Is Prescaling?

To make calculations using the input pulse to display the passing speed between two points, the distance between the two points and the display
unit must be set and the internally measured time multiplied by a certain coefficient. This coefficient is called the prescale value. (For information
on settings details, refer to the User's Manual.)

Time Unit Settings                                                              Input Type Setting

      Setting                                   Meaning                                                   NO: Voltage pulse high NC: Voltage pulse low

scal                      Prescale value menu setting                           No-contact or             00                 01
                                                                                voltage pulse
min                       Minute display                                        input

h.mm.ss                   h.mm.ss display                                       Contact                   10                 11
mm.ss.d                   mm.ss.d display (d = tenths of a second)
                                                                                Note: Set to 10 or 11 when there is a large variation in the display.
                                                                                        The largest measurement range is 30 Hz.

14         Timer Interval Indicator K3HB-P
Up/Down Counting Pulse Indicator

K3HB-C

Measure High-speed Up/down Pulses with
this Up/down Pulse Meter.

Perfect for Measuring Rotary Encoder and ON/OFF Pulse
Signals at High Speed

  Cumulative pulse input is 50 kHz, quadrature pulse inputs are 25 kHz,
  and up/down pulse inputs are 30 kHz.
Note: No-voltage contacts of up to 30 Hz are supported.

The count value can be converted to any value.

  The length equivalent for any pulse can be set to any desired value.
  This is effective for feed amount and position monitor displays.

         Refer to Common Precautions on page 30.

Model Number Structure

Model Number Legend

Base Units and Optional Boards can be ordered individually or as sets.

Base Units                             Base Units with Optional Boards

K3HB-C @                               K3HB-C@-@@@

15                                                                       1 234 5

1. Input Sensor Codes                  2. Sensor Power Supply/Output Type Codes
    NB: NPN input/voltage pulse input
    PB: PNP input                      None:                             None
                                       CPA:                              Relay output (PASS: SPDT) + Sensor power supply
5. Supply Voltage                                                        (12 VDC10%, 80 mA) (See note 1.)
    100-240 VAC: 100 to 240 VAC        L1A:
    24 VAC/VDC: 24 VAC/VDC                                               Linear current output (DC0(4)-20 mA) + Sensor power supply
                                                                         (12 VDC10%, 80 mA) (See note 2.)
Optional Board
                                       L2A:                              Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
Sensor Power Supply/Output Boards      A:                                (12 VDC10%, 80 mA) (See note 2.)
                                                                         Sensor power supply (12 VDC 10%, 80 mA)
K33-@
                                       FLK1A: Communications (RS-232C) + Sensor power supply
           2                                     (12 VDC10%, 80 mA) (See note 2.)

Relay/Transistor Output Boards         FLK3A: Communications (RS-485) + Sensor power supply
                                                 (12 VDC10%, 80 mA) (See note 2.)
K34-@
                                       3. Relay/Transistor Output Type Codes
           3                               None: None

Event Input Boards                     C1: Relay contact (H/L: SPDT each)
                                       C2: Relay contact (HH/H/LL/L: SPST-NO each)
K35-@
                                       T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
           4                           T2: Transistor (PNP open collector: HH/H/PASS/L/LL)

                                       BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
                                       DRT: DeviceNet (See note 2.)

                                       4. Event input Type Codes
                                           None: None

                                       1: 5 points (M3 terminal blocks) NPN open collector
                                       2: 8 points (10-pin MIL connector) NPN open collector

                                       3: 5 points (M3 terminal blocks) PNP open collector
                                       4: 8 points (10-pin MIL connector) PNP open collector

Note: 1. CPA can be combined with relay outputs only.

        2. Only one of the following can be used by each Digital Indicator:
            RS-232C/RS-485 communications, a linear output, or DeviceNet communications.

Accessories (Sold Separately)

K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable

                                                                 Up/Down Counting Pulse Indicator K3HB-C                             15
Specifications

Ratings

Supply voltage                      100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage
range                               85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
Power consumption
(See note 1.)                       100 to 240 VAC: 18 VA max. (max. load)
Current consumption                 24 VAC/DC: 11 VA/7 W max. (max. load)
Input
External power supply               DeviceNet power supply: 50 mA max. (24 VDC)

Event inputs Hold input             No-voltage, voltage pulse, open collector
                       Reset input
                       Bank input   12 VDC10% 80 mA

Output ratings Relay output         NPN open collector or no-voltage contact signal
                                    ON residual voltage: 2 V max.
(depends on                         ON current at 0 : 4 mA max.
                                    Max. applied voltage: 30 VDC max.
the model)   Transistor output      OFF leakage current: 0.1 mA max.

             Linear output          250 VAC, 30 VDC, 5 A (resistive load)
                                    Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
Display method
                                    Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max.
Main functions
                                    Linear output 0 to 20 mA DC, 4 to 20 mA:
Ambient operating temperature           Load: 500  max, Resolution: Approx. 10,000, Output error: 0.5% FS
Ambient operating humidity
Storage temperature                 Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Altitude                                Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS
Accessories
                                    (1 V or less: 0.15 V; not output for 0 V or less)

                                    Negative LCD (backlit LED) display
                                    7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))

                                    Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, display value
                                    selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, re-
                                    set

                                    -10 to 55C (with no icing or condensation)

                                    25% to 85%

                                    -25 to 65C (with no icing or condensation)

                                    2,000 m max.

                                    Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De-
                                    viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.)

Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
             attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is
             recommended.

        2. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
             Thin Cables.

16           Up/Down Counting Pulse Indicator K3HB-C
Characteristics

Display range                      -19,999 to 99,999
Measurement range
                                   Functions F1, F2: 2 gigacounts
Input signals
                                   Functions F3 : 0 to 4 gigacounts

                                    No-voltage contact (30 Hz max. with ON/OFF pulse width of 15 ms min.)

                                    Voltage pulse Mode Input frequency ON/OFF ON voltage OFF voltage                     Input

                                                                    range  pulse width                                    impedance

                                                      F1     0 to 30 kHz   16 s min. 4.5 to 30 V -30 to 2 V 10 k

                                                      F2     0 to 25 kHz   20 s min.

                                                      F3     0 to 50 kHz   9 s min.

                                    Open collector    Mode  Input frequency ON/OFF

                                                      F1            range  pulse width      Note: The Up/Down Counting Pulse
                                                      F2                                            Meter will malfunction if a pulse
                                                      F3     0 to 30 kHz   16 s min.               greater than the input frequency
                                                                                                    range is input. SYSERR may
                                                             0 to 25 kHz   20 s min.               appear on the display.

                                                             0 to 50 kHz   9 s min.

Connectable sensors                ON residual voltage: 3 V max.

Max. No. of display digits         OFF leakage current: 1.5 mA max.
Comparative output response
time                               Load current:          Must have a switching capacity of 20 mA or higher.

Linear output response time                               Must be able to properly switch load currents of 5 mA or less.

Insulation resistance              5 (-19999 to 99999)
Dielectric strength
Noise immunity                     1 ms max.: Transistor output; 10 ms max.: Relay contact output
                                   (time until the comparative output is made when there is a forced sudden change in the input signal from 15%
                                   to 95% or 95% to 15%)

                                   10 ms max. (time until the final analog output value is reached when there is a forced sudden change in the
                                   input signal from 15% to 95% or 95% to 15%)

                                   20 M min. (at 500 VDC)

                                   2,300 VAC for 1 min between external terminals and case

                                   100 to 240 VAC models:
                                       1,500 V at power supply terminals in normal or common mode
                                       (waveform with 1-ns rising edge and pulse width of 1 s/100 ns)

                                   24 VAC/VDC models:
                                       1,500 V at power supply terminals in normal or common mode
                                       (waveform with 1-ns rising edge and pulse width of 1 s/100 ns)

Vibration resistance               Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions

Shock resistance                   150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions

Weight                             Approx. 300 g (Base Unit only)

Degree of             Front panel  Conforms to NEMA 4X for indoor use (equivalent to IP66)
protection            Rear case
                                   IP20

                      Terminals    IP00 + finger protection (VDE0106/100)

Memory protection                  EEPROM (non-volatile memory)
                                   Number of rewrites: 100,000

Applicable standards               UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
                                   EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
                                   EN61326: 1997, A1: 1998, A2: 2001

EMC                                EMI: EN61326+A1 industrial applications

                                   Electromagnetic radiation interference
                                       CISPR 11 Group 1, Class A: CISPRL16-1/-2

                                   Terminal interference voltage
                                       CISPR 11 Group 1, Class A: CISPRL16-1/-2

                                   EMS: EN61326+A1 industrial applications

                                   Electrostatic Discharge Immunity
                                       EN61000-4-2: 4 kV (contact), 8 kV (in air)

                                   Radiated Electromagnetic Field Immunity
                                       EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)

                                   Electrical Fast Transient/Burst Immunity
                                       EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)

                                   Surge Immunity
                                       EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)

                                   Conducted Disturbance Immunity
                                       EN61000-4-6: 3 V (0.15 to 80 MHz)

                                   Power Frequency Magnetic Immunity
                                       EN61000-4-8: 30 A/m (50 Hz) continuous time

                                   Voltage Dips and Interruptions Immunity
                                       EN61000-4-11: 0.5 cycle, 0/180, 100% (rated voltage)

                                                                    Up/Down Counting Pulse Indicator K3HB-C                            17
Operation

Functions (Operating Modes)

F1 to F3

    Function name               Function No.

Individual inputs            f1

Phase differential inputs f2

Pulse counting input f3

Function                                       Operation                                                  Operation image (application)

F1          Counts input A as incremental pulses and input B as                                           Counting the number of people entering an area
Individual  decremental pulses. The count is incremented on the
inputs      rising edge of input A and decremented on the rising                                                                                                  Photoelectric
            edge of input B. If both inputs rise at the same time, the                                                                                            sensor
            count is not changed. The count is incremented when                                                                                                                   BCD output To
            input B is later than input A and decremented when input                                                                                                                                Programmable
            B is earlier than input A.                                                                                                                                                              Controller

            Input A H
                       L

            Input B       H                                                                               Increment
                          L                                                                                         Decrement

            HOLD input    H
                          L
                                                              3                                        3

                                                   2                      2                      2

                                         1                                              11
                    Count 0

F2          This function is normally used when connected to an                                           Detecting position and speed on a semiconductor wafer conveyor line

Phase dif- incremental rotary encoder. The count is incremented on                                                                              Wafer

ferential in- the falling edge of input B when input A is OFF. The count

puts        is decremented on the rising edge of input B when input

            A is OFF.

            Input A H                          (See note 2.)
                       L

            Input B  H
                     L

            HOLD H                                                                                                                                                           E6L
             input L
                                                                       3                                  Counting the number of workpieces

                                                   2                         2

                                            1                                           1           1

                   Count     0                                                              0

F3          Counted on the rising edge of input A
Pulse
counting    Input A  H
input                L

            HOLD H                                                                            6                                                                                   BCD output To
             input L                                                                    5                                                                                                           Programmable
                                                                                                                                                                                                    Controller
                                                                                     4
                                                          3
                                                 2
                                        1
                   Count 0

Note: 1. Meaning of H and L in Display

            Symbol              Input method No-voltage input

                             H                                Short-circuit

                             L                                Open

      2. Requires at least half the minimum signal width. If there is less than half, a 1 count error may occur.

Input Type Setting

                                               NO: Voltage pulse high NC: Voltage pulse low

No-contact or voltage pulse input 00                                                        01

Contact                                        10                                           11

18          Up/Down Counting Pulse Indicator K3HB-C
What Is Prescaling?

Prescaling converts the count value to any numeric value.
To display @@@@.@ mm in a system that outputs 250 pulses for a 0.5-m feed,

    the length per pulse = 500 mm (0.5 m) 250 = 2.
1. The prescale value for the K3HB-C is set using the mantissa X exponent Y,

    so the prescale value = 2.0000 10,
                               X = 2.000, and Y = 00.

2. Next, set the decimal point position for one digit to the right of the decimal point:

                   0.5 m

         250 pulses
                      K3HB-C

Encoder

                              Up/Down Counting Pulse Indicator K3HB-C                     19
Common Specifications

Event Input Ratings

K3HB-R        S-TMR, HOLD, RESET, BANK1, BANK2, BANK4
K3HB-P/-C
Contact       HOLD, RESET, BANK1, BANK2, BANK4
No-contact
              ON: 1 k max., OFF: 100 k min.

              ON residual voltage:         2 V max.

              OFF leakage current: 0.1 mA max.

              Load current:                4 mA max.

              Maximum applied voltage: 30 VDC max.

Output Ratings

Contact Output                                                        Transistor Outputs

        Item        Resistive loads                Inductive loads    Maximum load voltage 24 VDC
                  (250 VAC, cos=1;                (250 VAC, closed
Rated load        30 VDC, L/R=0 ms)               circuit, cos=0.4;   Maximum load current 50 mA
                                                30 VDC, L/R=7 ms)
Rated through    5 A at 250 VAC                                       Leakage current                    100 A max.
current          5 A at 30 VDC             1 A at 250 VAC
Mechanical life  5A                        1 A at 30 VDC
expectancy
Electrical life  5,000,000 operations
expectancy
                 100,000 operations

Linear Output

    Item           Outputs 0 to 20 mA 4 to 20 mA            0 to 5 V  1 to 5 V  0 to 10 V
                                                        5 k min.
Allowable load impedance 500  max.

Resolution                   Approx. 10,000

Output error                 0.5% FS                   0.5% FS
                                                        (0.15 V for 1 V or less and no output for 0 V)

Serial Communications Output                                          BCD Output I/O Ratings
                                                                      (Input Signal Logic: Negative)
    Item           Type                RS-232C, RS-485

Communications method Half duplex                                               I/O signal name                       Item  Rating

Synchronization method Start-stop synchronization (asynchronous)      Inputs    K3HB-R/P       K3HB-C    Input signal       No-voltage
                                                                                REQUEST        REQUEST                      contact input
Baud rate                9600/19200/38400 bps                                   HOLD           COMPEN-
                                                                                MAX            SATION
Transmission code        ASCII                                                  MIN            RESET     Input current for  10 mA
                                                                                RESET                    no-voltage input
Data length              7 bits or 8 bits

Stop bit length          2 bits or 1 bit                                                                 Signal ON voltage 1.5 V max.
                                                                                                         level OFF voltage 3 V min.
Error detection          Vertical parity and FCS

Parity check             Odd, even                                    Outputs DATA                       Maximum load       24 VDC
                                                                                   POLARITY              voltage
                                                                                   OVER
                                                                                   DATA VALID            Maximum load       10 mA
                                                                                   RUN                   current

                                                                                                         Leakage current 100 A max.

                                                                                K3HB-R/P       K3HB-C    Maximum load       24 VDC
                                                                                HH             OUT1      voltage            50 mA
                                                                                H              OUT2                         100 A max.
                                                                                PASS           OUT3      Maximum load
                                                                                L              OUT4      current
                                                                                LL             OUT5
                                                                                                         Leakage current

                                                                      Refer to the K3HB Communications User's Manual (Cat. No. N129)
                                                                      for details on serial and DeviceNet communications.

20            Digital Indicators K3HB-R/-P/-C
DeviceNet Communications

Communications protocol                  Conforms to DeviceNet
                                         Master-Slave connection (polling, bit-strobe, COS, cyclic)
Supported  Remote I/O                    Conforms to DeviceNet communications standards.
                                         Allocate any I/O data using the Configurator.
communications communications            Allocate any data, such as DeviceNet-specific parameters and variable area for Digital Indicators.
                                         Input area: 2 blocks, 60 words max.
           I/O allocations               Output area: 1 block, 29 words max.
                                         (The first word in the area is always allocated for the Output Execution Enabled Flags.)
                         Message         Explicit message communications
                         communications  CompoWay/F communications commands can be executed
                                         (using explicit message communications)
Connection methods                       Combination of multi-drop and T-branch connections (for trunk and drop lines)
Baud rate                                DeviceNet: 500, 250, or 125 Kbps (automatic follow-up)
Communications media                     Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line)
Communications distance
                                                 Baud rate      Network length     Drop line length          Total drop line length
                                         500 Kbps                     (max.)              (max.)                       (max.)
                                         250 Kbps
                                         125 Kbps           100 m max.          6 m max.                     39 m max.
                                                            (100 m max.)
                                                                                6 m max.                     78 m max.
                                                            100 m max.
                                                            (250 m max.)        6 m max.                     156 m max.

                                                            100 m max.
                                                            (500 m max.)

Communications power supply              The values in parentheses are for Thick Cable.
Allowable voltage fluctuation range      24-VDC DeviceNet power supply
Current consumption                      11 to 25-VDC DeviceNet power supply
Maximum number of nodes                  50 mA max. (24 VDC)
Maximum number of slaves                 64 (DeviceNet Configurator is counted as one node when connected.)
Error control checks                     63
DeviceNet power supply                   CRC errors
                                         Supplied from DeviceNet communications connector

                                                            Digital Indicators K3HB-R/-P/-C                                          21
Connections

External Connection Diagrams

Terminal Arrangements

Note: Refer to "Internal Block Diagram" on page 24 for information on isolation.                              A          B    C  D         E

A Operating Power Supply                                                           1

                                                                                   2

           100 to 240 VAC                                                          3

              24 VAC/VDC                                                           4

                                                                                                           5

                  A1

                                                                                                           6

                  A2

*Check the required power supply type.

B Sensor Power Supply/Output

Sensor power supply + PASS output          C Relays, Transistors, BCD and DeviceNet

                  B1

           PASS B2                         Relay Outputs  Relay Outputs                                       Transistor Outputs DeviceNet Connector (Included)
                                                           
                  B3                                                                                                    

              N/C B4                             C1        HH C1                    HH C1                        NPN     PNP
                                           H C2             H C2                     H C2
    12 VDC        B5 Sensor                               COM C3                   PASS C3                                          12345
    80 mA                                        C3         L C4                     L C4
                       power                     C4        LL C5                     LL C5
                  B6 supply                L C5           COM C6                   COM C6
                                                 C6
                                                                                                                         1: V- (Power supply cable: Black)
                                                                                                                              2: CAN L (Communications cable: Blue)
Sensor power supply + linear output                                                                                           3: Shield
                                                                                                                              4: CAN H (Communications cable: White)
    0-5/1-5/  N/C          + B1            BCD (NPN Open Collector):                                                     5: V+ (Power supply cable: Red)
    0-10 V                                 Applicable Connector (Sold separately)                                             Applicable Connector:
              0-20/        - B2            HDR-E50MAG1                                                                        HR31-5.08P-5SC (01)
    N/C       4-20 mA      + B3            (HONDA TSUSHIN KOGYO CO., LTD.)                                                    (HIROSE ELECTRIC CO., LTD.)
                                           Special Cable (Sold separately)                                                    * Attach the provided crimp terminals.
    12 VDC    12 VDC       - B4            K32-BCD (OMRON)
    80 mA     80 mA        +               (HDR-E50MAG1 with 0.3-m cable)

                              B5 Sensor
                                   power

                           - B6 supply

   

    Sensor power supply

                  B1                       The BCD COMMON is shared.
                                           The pins indicated in the above diagram
                       B2                  as blank (white) boxes have been removed.
                                           *Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet.
              N/C
                       B3

    12 VDC           B4                              Contact Outputs                                                     Transistor Outputs
    80 mA                                                                                                                (NPN Open Collector)
                  +                                                     5V
                     B5 Sensor
                           power
                     B6 supply

                  -

                                                                                                           HH                               HH
                                                                                                              H                                H
Sensor power supply + communications                                                                          L                                L
                                                                                                              LL                               LL
    B (+)     SD           B1                                                                                 PASS                             PASS

    A (-)     RD           B2

    B (+)     SG           B3

    A (-)     N/C             B4

    12 VDC    12 VDC       +
    80 mA     80 mA           B5 Sensor
                                    power
                              B6 supply                                          Safety Standards Conformance

                           -                         Always use a EN/IEC-compliant power supply with reinforced insulation or double
                                                       insulation for the DeviceNet power supply.
     RS-485 RS-232C
                                      The product must be used indoors for the above applicable standards to apply.

22            Digital Indicators K3HB-R/-P/-C
                                                                                                  K3HB-R                                 K3HB-R
                                                                                                  K3HB-P                                 K3HB-P
                                                                                                  K3HB-C

                        E Pulse Inputs                                NPN Input Model                                            PNP Input Model
                                                                      NPN input section
                                                                                                                                 E3, E6

                         Rotary Pulse Meter: K3HB-R                                              12 V                                   12 V
                         Timer Interval Meter: K3HB-P
                         Up/Down Counting Pulse Meter:                                                                          COM

                          K3HB-C                                         E2, E5                   510

                        NPN Input:         PNP Input:                                             700                                    700
                        K3HB-@NB           K3HB-@PB                                                                                       510
                                                                                                                                 E2, E5

                        Input A                         E1                  COM
                                   E1      Input A                         E3, E6

                        Voltage                        E2             Voltage pulse input section
                                   E2           PNP
                                                                                                               12 V
                            NPN                        E3 COM
                                   E3 COM                                                               510
                                                       E4
                        Input B            Input B                       E1, E4
                                   E4
                                                       E5                           10 k                700
                        Voltage                 PNP
                                   E5
                                                       E6 COM
                            NPN
                                   E6 COM

                        Note: E3 and E6, Note: E3 and E6, as

                        as well as B6,     well as B5,

                        are internally     are internally

                        connected.         connected.                    E3, E6

                        D Event Inputs

                        Models with Terminal Blocks                   Models with Connectors                         Use terminal pin D6 as the common terminal.
                                     <1> <3>                                    <2> <4>                               Use NPN open collector or no-voltage contacts

                                                       1: N/C         1          2  2: S-TMR                            for event input.
                                                       3: HOLD                      4: RESET                            PNP types are also available.

                        N/C                            5: COMPENSATION              6: COM                                                  12 V
                        S-TMR                                                                                                            4.7 k
                        HOLD                           7: BANK4       9        10   8: BANK2                         S-TMR : D2
                        RESET                          9: BANK1                     10: COM                           HOLD : D3
                        COMPENSATION                                                                                 RESET : D4
                        COM                Applicable Connector (Sold separately)
                                                 XG4M-1030 (OMRON)                                                                       3.9 k

                                           Special Cable (Sold separately)
                                                 K32-DICN (OMRON)

                                                                      (XG4M-1030 with 3-m cable)

                                           The following signals depend on the model:

                                           S-TMR: Used by the K3HB-R only.                                                   D6
                                                                                                                     COM
                                           COMPENSATION: Used by the K3HB-C only.

BCD Output Cable

Model                                                  Shape                                                                             Pin arrangement

K32-BCD                                                                              Connected device end                        COMMON            1
                                                                                   (PLC, display device, etc.)                                         20
             K3HB end                                                                                                                           1          4  104
                                                                                              46.5 mm                                              2       8
                                                                      D-sub connector (37-pin female)                                           2      21
                                                                      Cover: 17JE-37H-1A (manufactured by DDK)                           100    4                  OVER
                                                                      Connector: Equivalent to 17JE-13370-02                                       3
                                                                                                                                                8      22          DATA VALID
                                                                                     (manufactured by DDK)
                                                                      Stand: 17L-002A (manufactured by DDK)                                     1  4               RUN
                                                                                                                                                       23
                                                                                                                                                2                  COMMON
                                                                                                                                                4  5
                                                                                                                                         101           24          REQUEST

                                                                                                                                                8  6               MAX REQ.
                                                                                                                                                       25
                                                                                                                                                1                  MIN REQ.
                                                                                                                                                   7
                                                                                                                                                2      26          HOLD
                                                                                                                                                4
                                           300 mm                                                                                        102       8               RESET
                                                                                                                                                       27
                 38 mm                                                                                                                          8                  POLARITY
                                                                                                                                                   9
                                                                                                                                                1      28          HH

             Cover: HDR-E50LPA5                                                                                                                 2  10              H
                            (manufactured by Honda Tsushin Co., Ltd)                                                                            4      29
                                                                                                                                         103                       PASS
             Connector: HDR-E50MAG1                                                                                                                11
                            (manufactured by Honda Tsushin Co., Ltd)                                                                            8      30          L

                                                                                                                                                1  12              LL
                                                                                                                                                2      31
                                                                                                                                         104                       COMMON
                                                                                                                                                   13
                                                                                                                                                       32

                                                                                                                                                   14
                                                                                                                                                       33

                                                                                                                                                   15
                                                                                                                                                       34

                                                                                                                                                   16
                                                                                                                                                       35

                                                                                                                                                   17
                                                                                                                                                       36

                                                                                                                                                   18
                                                                                                                                                       37

                                                                                                                                                   19

Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent to 17JE-23370-02 (D1)
        (manufactured by DDK)

Special Cable (for Event Inputs with 8-pin Connector)

      Model             Appearance                                             Wiring
K32-DICN
                                                                      Pin No.  Signal name
             9 10                                                         1         N/C
                                                                          2
             12         3,000 mm                                          3       S-TMR
                                                                          4        HOLD
                 Cable marking (3 m)                                      5       RESET
                                                                          6
                                                                          7         N/C
                                                                          8        COM
                                                                          9       BANK4
                                                                         10       BANK2
                                                                                  BANK1
                                                                                   COM

                                                                                                  Digital Indicators K3HB-R/-P/-C                                            23
Derating Curve for Sensor Power Supply (Reference Values)Maximum current (mA)

For 12V

      140

                                                     1

      120

                      100

                      80

                      60

                      40

                      20

                      0            10 20 30 40 50 60
                      -20 -10 0

                                                     Ambient temperature (C)

Note: 1. The above values were obtained under test conditions with the standard mounting. The derating curve will vary with the mounting
             conditions, so be sure to adjust accordingly.

        2. Internal components may be deteriorated or damaged. Do not use the Digital Indicator outside of the derating range (i.e., do not use it in
             the area labeled (1), above).

Internal Block Diagram

                      Pulse input  Pulse input         Waveform                                Keys
                                      circuit        shaping circuit

                                                     EEPROM                                    Indications

       BCD I/O                        BCD               Drive                                  Drive                                    Transistor
                                                       circuit                                 circuit                                  output
   Event input                      Input circuit
                                    Output circuit    Waveform         Micro-                 Drive
Linear output                      Transistor      shaping circuit  computer                 circuit
Sensor power
                                     output circuit                                                         X                           Relay output
         supply
                                   Digital input     Drive                                     Drive           DeviceNet                DeviceNet
                                       circuit       circuit                                   circuit           circuit                Communications

                                   Linear output                                               Drive           Communi-
                                       circuit                                                 circuit           cations
                                                                                                                  driver
                                      Filter
                                                                                          VDD                                    VCOM
                                           VO        Power supply circuit (isolated)                           VO

                                                                Power supply                                               DC-DC
                                                                                                                  Converter (isolated)

24                                 Digital Indicators K3HB-R/-P/-C
BCD Output Timing Chart

A REQUEST signal from a Programmable Controller or other external device is required to read BCD data.

Single Sampling Data Output                                                                                  Continuous Data Output

                                    20-ms pulse min. (50 ms max.)                                                         REQ.
                                                                                                                          MAX.MIN.
REQ.
MAX.MIN.

                                                                                                                          DATA All data "High"                Data 1                    Data 2

DATA               All data "High"       Data                         All data "High"

DATA                                                                                                                      DATA
VALID                                                                                                                     VALID

                         Approx.         40 ms                                                                                               Approx.          40 ms             24 ms   40 ms      24 ms
                          30 ms                                                                                                               30 ms                64 ms                    64 ms
                                                             16 ms

The data is set in approximately 30 ms from the rising edge of the                                           Measurement data is output every 64 ms while the REQUEST signal
REQUEST signal and the DATA VALID signal is output.                                                          remains ON.
When reading the data from a Programmable Controller, start
reading the data when the DATA VALID signal turns ON.                                                        Note: If HOLD is executed when switching between data 1 and data
The DATA VALID signal will turn OFF 40 ms later, and the data will                                                   2, either data 1 or data 2 is output depending on the timing of
turn OFF 16 ms after that.                                                                                           the hold signal. The data will not go LOW.

The K3HB BCD output model has an open collector output, so wired OR connection is possible

      K3HB                                                          REQ. (1)
        (1)                                                         REQ. (2)

                                         Programmable
                                            Controller

      K3HB                                                          REQ. (3)
        (2)
                              DATA (including POL and               DATA                        (1)                              (2)                    (3)
      K3HB                    OVER) and DATA VALID
        (3)                   can be used in a wired OR.            DATA
                              RUN, HH, H, PASS, L, and              VALID
                              LL are always output, with or
                              without a REQUEST signal.                                                      (See note.)              (See note.)             (See note.)
                              Do not used a wired OR
                              connect for these signals.

                                                                           Note: Leave 20 ms min. between DATA VALID turning OFF and the REQUEST signal.

Programmable Controller Connection Example                                                                                Display Unit Connection Example

Digital Indicator                                           SYSMAC Programmable Controller                                Digital Indicator

                         Connector pin No. (See note.) DC Input Unit                                                                               Connector pin No. (See note.)
                                                                                                                                                   1.COMMON
                         1.COMMON        COM
                                                                                                                                                   2.1
                         2.1                            IN

                         3.2                            IN                                                                                         3.2
                                                                                                                                                         10
                         4.4        10                 IN                    Internal circuit
                                                                                                                                                   4.4

                         5.8                            IN                                                                                         5.8

                         23.DATA VALID                                                                                                             23.DATA VALID
                                                                                                                                                   24.RUN
                         24.RUN                         IN

                                                        IN                                                                                                                      To 101

                                                                                                                                                                   To 102

                         25.COMMON             Transistor Output Unit                                                                              25.COMMON
                                         OUT
                         26.REQUEST                                                                                                                                     Short-
                                                                                                                                                   26.REQUEST circuit

+5 V               240                                                    Internal circuit                                +5 V              240
             240                                                                           Internal circuit                           240

                   240   30.RESET           OUT                                                                                             240    30.RESET                     V
             240                                                                                                                      240                                         O
                         31.POLARITY       COM                                                                                                     31.POLARITY                       D
                         (+/- polarity)    (0 V)                                                                                                   (+/- polarity)                       C
                                         24 VDC                                                                                                                                            B
                                                                                                                                                                                              A
                                                     +24 V                                                                                                                                       DP
                                                              DC power                                                                                                                              LE
                                                                                                                                                                                                        V
                                                     0 V supply                                                                                                                                            O
                                                                                                                                                                                                              D
                                                                                                                                                                                                                 C
                                                                                                                                                                                                                    B
                                                                                                                                                                                                                       A
                                                                                                                                                                                                                          DP
                                                                                                                                                                                                                             LE
                                                                                                                                                                                                                                V
                                                                                                                                                                                                                                   O
                                                                                                                                                                                                                                      D
                                                                                                                                                                                                                                         C
                                                                                                                                                                                                                                            B
                                                                                                                                                                                                                                               A
                                                                                                                                                                                                                                                  DP
                                                                                                                                                                                                                                                     LE
                                                                                                                                                                                                                                                         V
                                                                                                                                                                                                                                                            O

                                                                                                                                                                                8 8 8 SEC

                                                                                                                                                                                        M7E-01D@N2, 01H@N2

                                                                                                                                                                                                   

                                                                              Note: The BCD output connector pin number is the D-sub connector pin number when
                                                                                      the BCD Output Cable (sold separately) is connected. This number differs from
                                                                                      the pin number for the Digital Indicator narrow pitch connector (manufactured by
                                                                                      Honda Tsushin Kogyo Co., Ltd.).

       Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator:
       K3HB-R/P/C Digital Indicator User's Manual (Cat. No. N136)
       The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp

                                                                                                                                Digital Indicators K3HB-R/-P/-C                                             25
Component Names and Functions                                                                                               PV display

   Max./Min. status indicator                                                                                         Displays PVs, maximum values,
                                                                                                                      minimum values, parameter
Turns ON when the maximum value or minimum                                                                           names, and error names.
value is displayed in the RUN level.
                                                                                                                           Position meter
    Level/bank display
                                                                                                                      Displays the position of the PV
In RUN level, displays the bank if the bank function is                                                              with respect to a desired scale.
ON. (Turns OFF if the bank function is OFF.)
In other levels, displays the current level.

  Comparative output                                   HH Max                                                                 SV display
    status indicators                                  H Min
                                                       PB                                                             Displays SV and monitor values.
Display the status of comparative
outputs.                                                     L
                                                        L
                                                                CMW            HH H
                                                       LL       Hold   T LL L

    Status indicators                                                                                                     SV display status indicators

Display  Function                                      MAX/MIN  LEVEL  MODE          SHIFT  UP                        K3HB-R

CMW      Lit when communications writing is ON                                                                  HH H  Indicator            Function
         (enabled) and not lit when OFF (prohibited).                                                  T LL L
                                                                                                                                   Turns ON when parameters for which
Hold     Turns ON/OFF when hold input turns                                                                     HH H
         ON/OFF.                                                                                                LL L      T teaching can be performed are

                                                                                                                                   displayed.

                                                                                                                      HH, H,      In RUN level, turn ON when the
                                                                                                                                  comparative set value HH, H, L, or LL
                                                                                                                      L, LL is displayed.

                                                                                                                      K3HB-P

                                                                                                                      Indicator            Function

                                                                                                                      HH, H,      In RUN level, turn ON when the
                                                                                                                                  comparative set value HH, H, L, or LL
                                                                                                                      L, LL is displayed.

                                                                                                                      K3HB-C

                                                                                                                      Indicator            Function

                                                                                            5  4  3                                Turns ON when parameters for which

                                                                                            T  1  2                       T teaching can be performed are

                                                                                                                                   displayed.

                                                                                                                      5,  4,  3,  In RUN level, turn ON when the
                                                                                                                                  comparative set value 1, 2, 3, 4, or 5 is
                                                                                                                      2, 1 displayed.

   MAX/MIN Key              LEVEL Key                       MODE Key                             SHIFT Key                               UP Key

Used to switch the     Used to switch level.           Used to switch the                   Used to change                        When changing a set
display between the                                    parameters displayed.                parameter settings.                   value, this key is used
PV, maximum value,                                                                          When changing a set                   to change the actual
and minimum value and                                                                       value, this key is used               value.
to reset the maximum                                                                        to move along the                     When a measurement
and minimum values.                                                                         digits.                               value is displayed, this
                                                                                                                                  key is used to execute
                                                                                                                                  or clear the forced-zero
                                                                                                                                  function or to execute
                                                                                                                                  teaching.

26       Digital Indicators K3HB-R/-P/-C
Dimensions

             101.2  Terminal cover (included)
              91
                                                                       Character Size for Main Display (mm)     Panel Cutout Dimensions
              96
                                                                         PV display  SV display                                      120 min.

                                                                            14.2          4.9

                    100                                                              3.5
                        (112)
                                             7.6                                                 75 min.

                                                                                                                92+00.8

                    12                                                                                                   45+00.6

                                                               1.3          95 *

                                                                         2

                    48                                                                    44.8

                                                                       *DeviceNet models: 97 mm

                                                                       Terminal: M3, Terminal Cover: Accessory

Wiring Precautions                                                          Mounting Method

For terminal blocks, use the crimp terminals suitable for M3 screws.      1. Insert the K3HB into the mounting cutout in the panel.
Tighten the terminal screws to the recommended tightening torque          2. Insert watertight packing around the Unit to make the mounting

  of approx. 0.5 Nm.                                                           watertight.
To prevent inductive noise, separate the wiring for signal lines from
                                                                                               Watertight
  that for power lines.                                                                            packing

Wiring

Use the crimp terminals suitable for M3 screws shown below.

5.8 mm max.

                                         5.8 mm max.                        3. Insert the adapter into the grooves on the left and right sides of
                                                                                the rear case and push until it reaches the panel and is fixed in
Unit Stickers (included)                                                        place.

No unit stickers are attached to the Digital Indicator.                                                                                     Adaptor
Select the appropriate units from the unit sticker sheets provided.

                                                                            LCD Field of Vision

                                                                            The K3HB is designed to have the best visibility at the angles shown
                                                                            in the following diagram.

Note: For measurements for commercial purposes, be sure to use
        the unit required by any applicable laws or regulations.

                                                                                    10

                                                                                      30

                                                                            Waterproof Packing

                                                                            The waterproof packing ensures a level of waterproofing that
                                                                            conforms to NEMA 4X. Depending on the operating environment,
                                                                            deterioration, contraction, or hardening may occur and replacement
                                                                            may be necessary. In this case, consult your OMRON
                                                                            representative.

                                                                            Digital Indicators K3HB-R/-P/-C                                    27
Main Functions

Main Functions and Features

Measurement                                                        Input Compensation

Function     func R P C                                            Auto-zero Times  at.za, at.zb R

The K3HB-R has the following six functions for receiving and       The frequency is forced to zero if there is no pulse input for a set
displaying input pulses.                                           period.
F1: Rotation (rpm)/circumferential speed
F2: Absolute ratio                                                 Input Compensation compn, com-p C
F3: Error ratio
F4: Rotational difference                                          The display can be changed to a preset compensation value using
F5: Flow rate ratio                                                the compensation input.
F6: Passing time
                                                                   Key Operations

The K3HB-P has the following six functions for receiving and       Teaching         RC
displaying input pulses.
F1: Passing speed                                                  The present measurement value can be used as a scaling value.
F2: Cycle
F3: Time difference                                                Key Protection   RPC
F4: Time band
F5: Measuring length                                               Key protection restricts level or parameter changes using the keys to
F6: Interval                                                       prevent unintentional key operations and malfunctions.

The K3HB-C has the following three functions for receiving and
displaying input pulses.
F1: Individual inputs
F2: Phase differential inputs
F3: Pulse counting input

Filters

Average Processing avg-t, avg-n R

Average processing of input signals with extreme changes or noise
smooths out the display and makes control stable.

Input Types  in-ta, in-tb R P
             in-ta C

Specify the types of sensor connected to input A and input B.

28        Digital Indicators K3HB-R/-P/-C
Outputs                                                              Display

Comparative Output Pattern out-p R P C                               Display Value Selection disp R P C

Standard, zone, and level comparative output patterns can be         The display value can be set to the present value, the maximum
selected for comparative outputs.                                    value, or the minimum value.

Hysteresis        hys R                                              Display Color Selection color R P C

Prevents comparative outputs from chattering when the                The present value display color can be set to green or red. The color
measurement value fluctuates slightly near the set value.            of the present value can also be switched according to the
                                                                     comparative output.

Output Refresh Stop o-stp R P                                        Display Refresh Period d.ref R P C

Holds the output status when a comparative result output other than  When the input changes rapidly, the display refresh period can be
PASS turns ON.                                                       lengthened to control flickering and make the display easier to read.

PASS Output Change pass R P                                          Position Meter    pos-t, pos-h, pos-l

Comparative results other than PASS and error signals can be                           RPC
output from the PASS output terminal.

Output OFF Delay  off-d R P C                                        The present measurement value can be displayed as a position in
                                                                     relation to the scaling width on a 20-gradation position meter.

Delays turning OFF comparatives for a set period. This can be used   Prescale          ps.ax, ps.ay, ps.bx, ps.by
to provide sufficient time to read the comparative output ON status
when the comparative result changes at short intervals.                                RPC

Shot Output       shot R P C                                         The input signal can be converted and displayed as any value.

Turns ON the comparative output for a specific time.                 Comparative Set Value Display sv.dsp R P C

Output Logic      out-n R P C                                        Select whether or not to display the comparative value during
                                                                     operation.

Reverses the output logic of comparative results.

Startup Compensation Timer s-tmr R                                   Display auto-return ret R P C

Measurements can be stopped for a set time using an external input.  Automatically returns the display to RUN level when there are no key
                                                                     operations (e.g., max./min. switching, bank settings using keys).

Output Test       test R P C                                         Other

Output operation can be checked without using actual input signals   Max./Min. Hold    RP
by using the keys to set a test measurement value.
                                                                     Holds the maximum and minimum measurement values.

Linear Outputs    lset.c, lset.v, lset.h, lset.l                     Bank Selection    bnk-c R P C

                  RPC                                                Switch between 8 comparative value banks using the keys on the
                                                                     front panel or external inputs. A set of set comparative values can be
A current or voltage proportional to the change in the measurement   selected as a group.
value can be output.

Standby Sequence stdby R P                                           Bank Copy         copy R P C

The comparison outputs can be kept OFF until the measurement         Any bank settings can be copied to all banks.
value enters the PASS range.

                                                                     Interruption Memory memo C

                                                                     The measured value can be recorded when the power supply is
                                                                     interrupted.

                                                                     User Calibration  RPC

                                                                     The K3HB can be calibrated by the user.

                                                                     Digital Indicators K3HB-R/-P/-C                                 29
Common Precautions                                              Precautions for Safe Use

Precautions                                                    1. Do not use the product in the following locations.

                           !WARNING                                  Locations subject to direct radiant heat from heating equipment

Do not touch the terminals while power is being supplied.            Locations where the product may come into contact with water
Doing so may possibly result in electric shock. Make sure             or oil
that the terminal cover is installed before using the
product.                                                             Locations subject to direct sunlight

Always provide protective circuits in the network. Without          Locations where dust or corrosive gases (in particular, sulfuric
protective circuits, malfunctions may possibly result in              or ammonia gas) are present
accidents that cause serious injury or significant property
damage. Provide double or triple safety measures in                  Locations subject to extreme temperature changes
external control circuits, such as emergency stop circuits,
interlock circuits, or limit circuits, to ensure safety in the       Locations where icing or condensation may occur
system if an abnormality occurs due to malfunction of the
product or another external factor affecting the product's          Locations subject to excessive shocks or vibration
operation.
                                                                2. Do not use the product in locations subject to temperatures or
                            !CAUTION                                humidity levels outside the specified ranges or in locations prone
                                                                    to condensation. If the product is installed in a panel, ensure that
Do not allow pieces of metal, wire clippings, or fine               the temperature around the product (not the temperature around
metallic shavings or filings from installation to enter the         the panel) does not go outside the specified range.
product. Doing so may occasionally result in minor
electric shock, fire, or malfunction.                           3. Provide sufficient space around the product for heat dissipation.

Do not use the product in locations where flammable or          4. Use and store the product within the specified temperature and
explosive gases are present. Doing so may occasionally              humidity ranges. If several products are mounted side-by-side or
result in minor or moderate explosion, causing minor or             arranged in a vertical line, the heat dissipation will cause the
moderate injury, or property damage.                                internal temperature of the products to rise, shortening the
                                                                    service life. If necessary, cool the products using a fan or other
Do not attempt to disassemble, repair, or modify the                cooling method.
product. Doing so may occasionally result in minor or
moderate injury due to electric shock.                          5. The service life of the output relays depends on the switching
                                                                    capacity and switching conditions. Consider the actual application
Do not use the equipment for measurements within                    conditions and use the product within the rated load and electrical
Measurement Categories II, III or IV (according to                  service life. Using the product beyond its service life may result in
IEC61010-1). Doing so may occasionally cause                        contact welding or burning.
unexpected operation, resulting in minor or moderate
injury, or damage to the equipment. Use the equipment           6. Install the product horizontally.
for measurements only within the Measurement Category
for which the product is designed.                              7. Mount to a panel between 1 and 8-mm thick.

Perform correct setting of the product according to the         8. Use the specified size of crimp terminals (M3, width: 5.8 mm
application. Failure to do so may occasionally cause                max.) for wiring. To connect bare wires, AWG22 (cross section:
unexpected operation, resulting in minor or moderate                0.326 mm2) to AWG14 (cross section: 2.081 mm2) to wire the
injury, or damage to the equipment.                                 power supply terminals and AWG28 (cross section: 0.081 mm2)
                                                                    to AWG16 (cross section: 1.309 mm2) for other terminals. (Length
Ensure safety in the event of product failure by taking             of exposed wire: 6 to 8 mm)
safety measures, such as installing a separate monitoring
system. Product failure may occasionally prevent                9. In order to prevent inductive noise, wire the lines connected to the
operation of comparative outputs, resulting in damage to            product separately from power lines carrying high voltages or
the connected facilities and equipment.                             currents. Do not wire in parallel with or in the same cable as
                                                                    power lines. Other measures for reducing noise include running
Tighten the screws on the terminal block and the                    lines along separate ducts and using shield lines.
connector locking screws securely using a tightening
torque within the following ranges. Loose screws may            10.Ensure that the rated voltage is achieved no longer than 2 s after
occasionally cause fire, resulting in minor or moderate             turning the power ON.
injury, or damage to the equipment.
                                                                11.Allow the product to operate without load for at least 15 minutes
     Terminal block screws: 0.43 to 0.58 Nm                        after the power is turned ON.
     Connector locking screws: 0.18 to 0.22 Nm
                                                                12.Do not install the product near devices generating strong high-
Make sure that the product will not be adversely affected           frequency waves or surges. When using a noise filter, check the
if the DeviceNet cycle time is lengthened as a result of            voltage and current and install it as close to the product as
changing the program with online editing. Extending the             possible.
cycle time may cause unexpected operation, occasionally
resulting in minor or moderate injury, or damage to the         13.Do not use thinner to clean the product. Use commercially
equipment.                                                          available alcohol.

Before transferring programs to other nodes or changing         14.Be sure to confirm the name and polarity for each terminal before
I/O memory of other nodes, check the nodes to confirm               wiring the terminal block and connectors.
safety. Changing the program or I/O memory of other
nodes may occasionally cause unexpected operation,              15.Use the product within the noted supply voltage and rated load.
resulting in minor or moderate injury, or damage to the
equipment.                                                      16.Do not connect anything to unused terminals.

                                                                17.Output turns OFF when the mode is changed or settings are
                                                                    initialized. Take this into consideration when setting up the control
                                                                    system.

                                                                18.Install an external switch or circuit breaker that complies with
                                                                    applicable IEC60947-1 and IEC60947-3 requirements and label
                                                                    them clearly so that the operator can quickly turn OFF the power.

                                                                19.Use the specified cables for the communications lines and stay
                                                                    within the specified DeviceNet communications distances. Refer
                                                                    to the User's Manual (Cat. No. N129) for details on
                                                                    communications distance specifications and cables.

30  Digital Indicators K3HB-R/-P/-C
20.Do not pull the DeviceNet communications cables with excessive
    force or bend them past their natural bending radius.

21.Do not connect or remove connectors while the DeviceNet power
    is being supplied. Doing so will cause product failure or
    malfunction.

22.Use cables with heat resistance of 70C min.

Noise Countermeasures

1. Do not install the product near devices generating strong high-
    frequency waves or surges, such as high-frequency welding and
    sewing machines.

2. Mount a surge suppressor or noise filter to peripheral devices
    generating noise, in particular, motors, transformers, solenoids,
    and magnet coils.

Line filter  Power supply input+
                                           Signal input
              Digital             Digital
                                                                Power supply inputIndicatorIndicator

                                                                          - Surge
                                                                              absorber

3. In order to prevent inductive noise, wire the lines connected to the
    terminal block separately from power lines carrying high voltages
    or currents. Do not wire in parallel with or in the same cable as
    power lines. Other measures for reducing noise include running
    lines along separate ducts and using shield lines.

   Example of Countermeasures for Inductive Noise on
   Input Lines

                                   +   Digital
                           Signal     Indicator
                           input

                                   -

             2 conductors
             with shield

4. If a noise filter is used for the power supply, check the voltage and
    current, and install the noise filter as close to the product as
    possible.

5. Reception interference may occur if the product is used close to a
    radio, television, or wireless.

                                                                                        Digital Indicators K3HB-R/-P/-C  31
Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY,
OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER
ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DIS-
CLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMER-
CIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLI-
GENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the custom-
er's application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products.
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

  safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. N135-E1-02 In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

Industrial Devices and Components Division H.Q.  Printed in Japan
Measuring Components Department                  0305 (0804)
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7080/Fax: (81)75-344-7189
Terms and Conditions of Sale

1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed                      ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
     part of all quotes, agreements, purchase orders, acknowledgments, price lists,              BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
     catalogs, manuals, brochures and other documents, whether electronic or in                  PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
     writing, relating to the sale of products or services (collectively, the "Products")        INTENDED USE. Omron further disclaims all warranties and responsibility of
     by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron                      any type for claims or expenses based on infringement by the Products or oth-
     objects to any terms or conditions proposed in Buyer's purchase order or other              erwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obli-
     documents which are inconsistent with, or in addition to, these Terms.                      gation hereunder shall be, at Omron's election, to (i) replace (in the form
                                                                                                 originally shipped with Buyer responsible for labor charges for removal or
2. Prices; Payment Terms. All prices stated are current, subject to change with-                 replacement thereof) the non-complying Product, (ii) repair the non-complying
     out notice by Omron. Omron reserves the right to increase or decrease prices                Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
     on any unshipped portions of outstanding orders. Payments for Products are                  the non-complying Product; provided that in no event shall Omron be responsi-
     due net 30 days unless otherwise stated in the invoice.                                     ble for warranty, repair, indemnity or any other claims or expenses regarding
                                                                                                 the Products unless Omron's analysis confirms that the Products were prop-
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices              erly handled, stored, installed and maintained and not subject to contamina-
     sent to Buyer after deducting transportation charges, taxes and duties, and will            tion, abuse, misuse or inappropriate modification. Return of any Products by
     be allowed only if (i) the invoice is paid according to Omron's payment terms               Buyer must be approved in writing by Omron before shipment. Omron Compa-
     and (ii) Buyer has no past due amounts.                                                     nies shall not be liable for the suitability or unsuitability or the results from the
                                                                                                 use of Products in combination with any electrical or electronic components,
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or                 circuits, system assemblies or any other materials or substances or environ-
     the maximum legal rate, whichever is less, on any balance not paid within the               ments. Any advice, recommendations or information given orally or in writing,
     stated terms.                                                                               are not to be construed as an amendment or addition to the above warranty.
                                                                                                 See http://oeweb.omron.com or contact your Omron representative for pub-
5. Orders. Omron will accept no order less than $200 net billing.                                lished information.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all               14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
                                                                                                 FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
     costs involved in, obtaining any government approvals required for the impor-               LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
     tation or sale of the Products.                                                             WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
7. Taxes. All taxes, duties and other governmental charges (other than general                   BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
     real property and income taxes), including any interest or penalties thereon,               Further, in no event shall liability of Omron Companies exceed the individual
     imposed directly or indirectly on Omron or required to be collected directly or             price of the Product on which liability is asserted.
     indirectly by Omron for the manufacture, production, sale, delivery, importa-          15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
     tion, consumption or use of the Products sold hereunder (including customs                  their employees from and against all liabilities, losses, claims, costs and
     duties and sales, excise, use, turnover and license taxes) shall be charged to              expenses (including attorney's fees and expenses) related to any claim, inves-
     and remitted by Buyer to Omron.                                                             tigation, litigation or proceeding (whether or not Omron is a party) which arises
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory              or is alleged to arise from Buyer's acts or omissions under these Terms or in
     to Omron, Omron reserves the right to stop shipments or require satisfactory                any way with respect to the Products. Without limiting the foregoing, Buyer (at
     security or payment in advance. If Buyer fails to make payment or otherwise                 its own expense) shall indemnify and hold harmless Omron and defend or set-
     comply with these Terms or any related agreement, Omron may (without liabil-                tle any action brought against such Companies to the extent based on a claim
     ity and in addition to other remedies) cancel any unshipped portion of Prod-                that any Product made to Buyer specifications infringed intellectual property
     ucts sold hereunder and stop any Products in transit until Buyer pays all                   rights of another party.
     amounts, including amounts payable hereunder, whether or not then due,                 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
     which are owing to it by Buyer. Buyer shall in any event remain liable for all              sive property of Omron Companies and Buyer shall not attempt to duplicate it
     unpaid accounts.                                                                            in any way without the written permission of Omron. Notwithstanding any
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation                     charges to Buyer for engineering or tooling, all engineering and tooling shall
     unless Buyer indemnifies Omron against all related costs or expenses.                       remain the exclusive property of Omron. All information and materials supplied
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery                by Omron to Buyer relating to the Products are confidential and proprietary,
     resulting from causes beyond its control, including earthquakes, fires, floods,             and Buyer shall limit distribution thereof to its trusted employees and strictly
     strikes or other labor disputes, shortage of labor or materials, accidents to               prevent disclosure to any third party.
     machinery, acts of sabotage, riots, delay in or lack of transportation or the          17. Export Controls. Buyer shall comply with all applicable laws, regulations and
     requirements of any government authority.                                                   licenses regarding (i) export of products or information; (iii) sale of products to
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:                   "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of
     a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship              regulated technology or information.
                                                                                            18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
        except in "break down" situations.                                                       and no course of dealing between Buyer and Omron shall operate as a waiver
     b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall          of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
                                                                                                 without Omron's written consent. (c) Law. These Terms are governed by the
        constitute delivery to Buyer;                                                            law of the jurisdiction of the home office of the Omron company from which
     c. All sales and shipments of Products shall be FOB shipping point (unless oth-             Buyer is purchasing the Products (without regard to conflict of law princi-
                                                                                                 ples). (d) Amendment. These Terms constitute the entire agreement between
        erwise stated in writing by Omron), at which point title and risk of loss shall          Buyer and Omron relating to the Products, and no provision may be changed
        pass from Omron to Buyer; provided that Omron shall retain a security inter-             or waived unless in writing signed by the parties. (e) Severability. If any provi-
        est in the Products until the full purchase price is paid;                               sion hereof is rendered ineffective or invalid, such provision shall not invalidate
     d. Delivery and shipping dates are estimates only; and                                      any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
     e. Omron will package Products as it deems proper for protection against nor-               against the amount owing in respect of this invoice. (g) Definitions. As used
        mal handling and extra charges apply to special conditions.                              herein, "including" means "including without limitation"; and "Omron Compa-
12. Claims. Any claim by Buyer against Omron for shortage or damage to the                       nies" (or similar words) mean Omron Corporation and any direct or indirect
     Products occurring before delivery to the carrier must be presented in writing              subsidiary or affiliate thereof.
     to Omron within 30 days of receipt of shipment and include the original trans-
     portation bill signed by the carrier noting that the carrier received the Products
     from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the
     Products will be free from defects in materials and workmanship for a period of
     twelve months from the date of sale by Omron (or such other period expressed
     in writing by Omron). Omron disclaims all other warranties, express or implied.
     (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
     EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1. Suitability of Use. Omron Companies shall not be responsible for conformity                   ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROP-
     with any standards, codes or regulations which apply to the combination of the              ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
     Product in the Buyer's application or use of the Product. At Buyer's request,               OVERALL EQUIPMENT OR SYSTEM.
     Omron will provide applicable third party certification documents identifying          2. Programmable Products. Omron Companies shall not be responsible for the
     ratings and limitations of use which apply to the Product. This information by              user's programming of a programmable Product, or any consequence thereof.
     itself is not sufficient for a complete determination of the suitability of the Prod-  3. Performance Data. Data presented in Omron Company websites, catalogs
     uct in combination with the end product, machine, system, or other application              and other materials is provided as a guide for the user in determining suitabil-
     or use. Buyer shall be solely responsible for determining appropriateness of                ity and does not constitute a warranty. It may represent the result of Omron's
     the particular Product with respect to Buyer's application, product or system.              test conditions, and the user must correlate it to actual application require-
     Buyer shall take application responsibility in all cases but the following is a             ments. Actual performance is subject to the Omron's Warranty and Limitations
     non-exhaustive list of applications for which particular attention must be given:           of Liability.
     (i) Outdoor use, uses involving potential chemical contamination or electrical         4. Change in Specifications. Product specifications and accessories may be
     interference, or conditions or uses not described in this document.                         changed at any time based on improvements and other reasons. It is our prac-
     (ii) Use in consumer products or any use in significant quantities.                         tice to change part numbers when published ratings or features are changed,
     (iii) Energy control systems, combustion systems, railroad systems, aviation                or when significant construction changes are made. However, some specifica-
     systems, medical equipment, amusement machines, vehicles, safety equip-                     tions of the Product may be changed without any notice. When in doubt, spe-
     ment, and installations subject to separate industry or government regulations.             cial part numbers may be assigned to fix or establish key specifications for
     (iv) Systems, machines and equipment that could present a risk to life or prop-             your application. Please consult with your Omron's representative at any time
     erty. Please know and observe all prohibitions of use applicable to this Prod-              to confirm actual specifications of purchased Product.
     uct.                                                                                   5. Errors and Omissions. Information presented by Omron Companies has been
     NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS                                  checked and is believed to be accurate; however, no responsibility is assumed
     RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT                                     for clerical, typographical or proofreading errors or omissions.
     ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
    &RPSOHWH 7HUPV DQG &RQGLWLRQV RI 6DOH IRU SURGXFW SXUFKDVH DQG XVH DUH RQ 2PURQV ZHEVLWH
    DW ZZZRPURQFRPRHL XQGHU WKH $ERXW 8V WDE LQ WKH /HJDO 0DWWHUV VHFWLRQ

$// ',0(16,216 6+2:1 $5( ,1 0,//,0(7(56

7R FRQYHUW PLOOLPHWHUV LQWR LQFKHV PXOWLSO\ E\  7R FRQYHUW JUDPV LQWR RXQFHV PXOWLSO\ E\

20521 (/(&7521,&6 //&                        20521 &$1$'$ ,1&             20521 21/,1(

2QH &RPPHUFH 'ULYH                            0LOQHU $YHQXH               *OREDO  KWWSZZZRPURQFRP
6FKDXPEXUJ ,/                                7RURQWR 2QWDULR 0% 9         86$  KWWSZZZRPURQFRPRHL
                                                                          &DQDGD  KWWSZZZRPURQFD
                                             

)RU 86 WHFKQLFDO VXSSRUW RU RWKHU LQTXLULHV



Cat. No. N135-E1-02 1/06 Specifications subject to change without notice  Printed in USA
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

技术资料推荐

论坛推荐

技术视频推荐

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved