Controllers 12VDC PS +/-10% 80mA

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Controllers
RoHS:YES
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
1350662 K33A

K33-A器件文档内容

    Temperature Indicator

    K3HB-H

                                                                                                                                               CSM_K3HB-H_DS_E_13_1

New High-speed, High-precision Temperature

Indicator

• Visual confirmation of judgement results through display colors that

switch between red and green. *1

• Capable of high-speed sampling at 50 times per second (20 ms).

• High-resolution of 0.01°C with platinum-resistance thermometer Pt100

input. Thermocouple sensor inputs also support a resolution of 0.1°C for

all ranges.

• Temperature input shift is easily set using two points.

    Display

                                      Input

                                      compensation

                                      value 2

                        After

                        compensation

             Input

             compensation                                                                                      For the most recent information on models that have been certified for

             value 1

                               Before                                                                          safety standards, refer to your OMRON website.

                               compensation

    0               Input                    Input          Input

                    compensation             compensation

                    input value 1            input value 2

• Series expanded to include DeviceNet models. *2

• UL certification approval (Certification Mark License).

• CE Marking conformance by third party assessment body.

• Water-resistant enclosure conforms to NEMA 4X (equivalent

to IP66).

*1 Visual confirmation of judgement results is not supported on models that do

    not have an output or models that do not support DeviceNet.

    You can change the display color by setting it, but you cannot switch it based on the

    judgement results.

*2 DeviceNet models have a depth of 97 mm.

       Refer to Safety Precautions for All Digital Panel Meters.

Model Number Structure

■ Model Number Legend

Base Units and Optional Boards can be ordered individually         or  as                  sets.

Base Units                                                                                        Base Units with Optional Boards

K3HB-H@                                                                                           K3HB-H@-@@@

             1             5                                                                                   1     2  34  5

1.  Input Sensor Code                                                                             2.  Sensor Power Supply/Output Type Code

    TA: Temperature input                                                                             None:    None

       Thermocouple input/Platinum-resistance thermometer input                                       CPA:     Relay output (PASS: SPDT) + Sensor power supply

5.  Supply Voltage                                                                                             (12 VDC +/−10%, 80 mA) (See note 1.)

                                                                                                      L1A:     Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply

    100-240 VAC: 100 to 240 VAC                                                                                (12 VDC +/−10%, 80 mA) (See note 2.)

    24 VAC/VDC: 24 VAC/VDC                                                                            L2A:     Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power

                                                                                                               supply (12 VDC +/−10%, 80 mA) (See note 2.)

                                                                                                      A:       Sensor power supply (12 VDC +/−10%, 80 mA)

                                                                                                      FLK1A:   Communications (RS-232C) + Sensor power supply

                                                                                                               (12 VDC +/−10%, 80 mA) (See note 2.)

                                                                                                      FLK3A:   Communications (RS-485) + Sensor power supply

                                                                                                               (12 VDC +/−10%, 80 mA) (See note 2.)

                                                                                                  Note:    1.  CPA can be combined with relay outputs only.

                                                                                                           2.  Only one of the following can be used by each Digital Indicator: RS-232C/

                                                                                                               RS-485 communications, a linear output, or DeviceNet communications.

Optional Boards

Sensor Power Supply/Output Boards                                                                 3.  Relay/Transistor Output Type Code

K33-@                                                                                                 None:    None

                                                                                                      C1:      Relay contact (H/L: SPDT each)

       2                                                                                              C2:      Relay contact (HH/H/LL/L: SPST-NO each)

Relay/Transistor Output Boards                                                                        T1:      Transistor (NPN open collector: HH/H/PASS/L/LL)

                                                                                                      T2:      Transistor (PNP open collector: HH/H/PASS/L/LL)

K34-@                                                                                                 BCD *: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)

       3                                                                                              DRT:     DeviceNet (See note 2.)

                                                                                                      * A Special BCD Output Cable (sold separately) is required.

Event Input Boards                                                                                4.  Event Input Type Code

K35-@                                                                                                 None:    None

                                                                                                      1:       5 inputs (M3 terminal blocks), NPN open collector

       4                                                                                              2:       8 inputs (10-pin MIL connector), NPN open collector

                                                                                                      3:       5 inputs (M3 terminal blocks), PNP open collector

                                                                                                      4:       8 inputs (10-pin MIL connector), PNP open collector

Note: The following combinations are not possible.

    • Communications (FLK@A) + DeviceNet (DRT)
    • Communications (FLK@A) + BCD output (BCD)

    • Linear current/voltage (L@A) + DeviceNet (DRT)

                                                                                                                                                                                          1
                                                                                                                                                  K3HB-H

Accessories (Sold Separately)

K32-DICN: Special Cable (for event inputs, with 8-pin connector)

K32-BCD: Special BCD Output Cable

Watertight Cover                                                                      Rubber Packing

                     Model                                                                               Model

Y92A-49N                                                                               K32-P1

                                                                                      Note: Rubber packing is provided with the Controller.

Specifications

■ Ratings

Power supply voltage                            100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC

Allowable power supply voltage range            85% to 110% of the rated power supply voltage, DeviceNet power supply: 11        to  25  VDC

Power consumption                               100 to 240 V: 18 VA max. (max. load)

(See note 1.)                                   24 VAC/DC: 11 VA/7 W max. (max. load)

Current consumption                             DeviceNet power supply: 50 mA max. (24 VDC)

Input                                           Platinum-resistance thermometer: Pt100

                                                Thermocouple: K, J, T, E, L, U, N, R, S, B, W

A/D conversion method                           Delta-Sigma method

External power supply                           See Sensor Power Supply/Output Type Codes

Event inputs          Timing input              NPN open collector or no-voltage contact signal

(See note 2.)                                   ON residual voltage: 3 V max.

                                                ON current at 0 Ω: 17 mA max.

                                                Max. applied voltage: 30 VDC max.

                                                OFF leakage current: 1.5 mA max.

                      Startup compensa-         NPN open collector or no-voltage contact signal

                      tion timer input          ON residual voltage: 2 V max.

                      Hold input                ON current at 0 Ω: 4 mA max.

                                                Max. applied voltage: 30 VDC max.

                      Reset input               OFF leakage current: 0.1 mA max.

                      Bank input

Output ratings        Relay output              250 VAC, 30 VDC, 5 A (resistive load)

(depends on the                                 Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations

model)                Transistor output         Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 μA max.

                      Linear output             Linear output 0 to 20 mA DC, 4 to 20 mA DC:

                                                     Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS

                                                Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:

                                                     Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS

                                                     (1 V or less: ±0.15 V; not output for 0 V or less)

Display method                                  Negative LCD (backlit LED) display

                                                7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)

Main functions                                  Temperature input shift, measurement operation selection, averaging, previous average value comparison,

                                                zero-limit, output hysteresis, output OFF delay, output test, display value selection, display color selection, key

                                                protection, bank selection, display refresh period, maximum/minimum hold, reset

Ambient operating temperature                   −10 to 55°C (with no icing or condensation)

Ambient operating humidity                      25% to 85%

Storage temperature                             −25 to 65°C (with no icing or condensation)

Altitude                                        2,000 m max.

Accessories                                     Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include

                                                a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note

                                                3.)

Note: 1.   DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is

           required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended.

       2.  PNP input types are also available.

       3.  For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Ca-

           bles.

                                                                                                                                                                     2
                                                                                                                                    K3HB-H

■ Characteristics

Display range                     −19,999 to 99,999

Accuracy                          Thermocouple input: (±0.3% PV or ±1°C, whichever is larger) ± 1 digit max. (See note.)

                                  Platinum resistance thermometer input: (±0.2% PV or ±0.8°C, whichever is larger) ± 1 digit max.

Sampling period                   20 ms (50 times/second)

Comparative output response time  Platinum-resistance thermometer input range: 120 ms max.

                                  Thermocouple input range: 180 ms max.

                                  (The time until the comparative output is output when there is a forced sudden change in the input signal

                                  from 15% to 95% or 95% to 15%.)

Linear output response time       Platinum-resistance thermometer input range: 170 ms max.

                                  Thermocouple input range: 230 ms max.

                                  (The time until the final analog output is reached when there is a forced sudden change in the output signal

                                  from 15% to 95% or 95% to 15%.)

Insulation resistance             20 MΩ min. (at 500 VDC)

Dielectric strength               2,300 VAC for 1 min between external terminals and case

Noise immunity                    100 to 240 VAC models:

                                         ±1,500 V at power supply terminals in normal or common mode

                                         (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)

                                  24 VAC/VDC models:

                                         ±1,500 V at power supply terminals in normal or common mode

                                         (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)

Vibration resistance              Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions

Shock resistance                  150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions

Weight                            Approx. 300 g (Base Unit only)

Degree of pro-    Front panel     Conforms to NEMA 4X for indoor use (equivalent to IP66)

tection           Rear case       IP20

                  Terminals       IP00 + finger protection (VDE0106/100)

Memory protection                 EEPROM (non-volatile memory)

                                  Number of rewrites: 100,000

Applicable standards              UL61010-1, CSA C22.2 No. 61010-1-04

                                  EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II

                                  EN61326-1

EMC                               EMI: EN61326 industrial applications

                                  Electromagnetic radiation interference

                                         CISPR 11 Group 1, Class A

                                  Terminal interference voltage

                                         CISPR 11 Group 1, Class A

                                  EMS: EN61326 industrial applications

                                  Electrostatic Discharge Immunity

                                         EN61000-4-2: 4 kV (contact), 8 kV (in air)

                                  Radiated Electromagnetic Field Immunity

                                         EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to      1  GHz,  1.4  to  2  GHz)

                                  Electrical Fast Transient/Burst Immunity

                                         EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)

                                  Surge Immunity

                                         EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)

                                  Conducted Disturbance Immunity

                                         EN61000-4-6: 3 V (0.15 to 80 MHz)

                                  Power Frequency Magnetic Immunity

                                         EN61000-4-8: 30 A/m (50 Hz) continuous time

                                  Voltage Dips and Interruptions Immunity

                                         EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)

Note: K, T, N (–100°C or less): ±2°C ±1 digit max.

     U, L: ±2°C ±1 digit max.

     B (400°C max.): Nothing specified.

     R, S (200°C max.): ±3°C ±1 digit max.

     W: (±0.3% PV or ±3°C whichever is larger) ±1 digit max.

                                                                                                                                                3
                                                                                                                                              K3HB-H

■ Input Ranges

Platinum-resistance Thermometer/Thermocouple

Input type         Platinum-                                                              Thermocouple

                   resistance

                   thermometer

Name                   Pt100                    K                  J            T      E          L           U       N       R       S       B       W

                                                                                                                                                      (W/Re

                                                                                                                                                      5-26)

Connected          E4      E5      E6                                                         E5          E6

terminals

Tem-         2300                                                                                                                                     2300.0

pera-                                                                                                                         1700.0  1700.0  1800.0

ture         1800                       1300.0                                                                        1300.0

range        1300

(°C)          900  850.0                                   850.0                              850.0

              800

              700                                  500.0                               600.0

              600                                                     400.0     400.0                         400.0

              400          150.00

              200

              100                                                                                                                             100.0

              0                                                                        0.0                                    0.0     0.0             0.0

             −100                                  −20.0   −100.0     −20.0                   −100.0

             −200  −200.0  −150.00      −200.0                               −200.0                           −200.0  −200.0

Setting code       0-pt        1-pt     2-k        3-k     4-j        5-j       6-t    7-e        8-l         9-u     10-n    11-r    12-s    13-b    14-w

Minimum            0.1°C   0.01°C                                                             0.1°C

setting unit

(comparative

set value)

The range shown in dark shading indicates the factory setting.

Celsius/Fahrenheit Correlation Values and Setting/Specified Ranges

Input type                     Setting  range                         Indication range

                       °C                       °F                    °C                  °F

Pt100 (1)          −200.0 to 850.0      −300.0 to 1500.0   −305.0 to 955.0             −480.0 to 1680.0

Pt100 (2)          −150.00 to 150.00    −199.99 to 300.00  −180.00 to 180.00           −199.99 to 350.00

      K (1)        −200.0 to 1300.0     −300.0 to 2300.0   −350.0 to 1450.0            −560.0 to 2560.0

      K (2)        −20.0 to 500.0       0.0 to 900.0            −72.0 to 552.0         −90.0 to 990.0

      J (1)        −100.0 to 850.0      −100.0 to 1500.0   −195.0 to 945.0             −260.0 to 1660.0

      J (2)        −20.0 to 400.0       0.0 to 750.0            −62.0 to 442.0         −75.0 to 825.0

       T           −200.0 to 400.0      −300.0 to 700.0    −260.0 to 460.0             −400.0 to 800.0

       E           0.0 to 600.0         0.0 to 1100.0           −60.0 to 660.0         −110.0 to 1210.0

       L           −100.0 to 850.0      −100.0 to 1500.0   −195.0 to 945.0             −260.0 to 1660.0

       U           −200.0 to 400.0      −300.0 to 700.0    −260.0 to 460.0             −400.0 to 800.0

       N           −200.0 to 1300.0     −300.0 to 2300.0   −350.0 to 1450.0            −560.0 to 2560.0

       R           0.0 to 1700.0        0.0 to 3000.0      −170.0 to 1870.0            −300.0 to 3300.0

       S           0.0 to 1700.0        0.0 to 3000.0      −170.0 to 1870.0            −300.0 to 3300.0

       B           100.0 to 1800.0      300.0 to 3200.0    −70.0 to 1970.0             10.0 to 3490.0

       W           0.0 to 2300.0        0.0 to 4100.0      −230.0 to 2530.0            −410.0 to 4510.0

                                                                                                                                                              4
                                                                                                                                                     K3HB-H

Common Specifications

■ Event Input Ratings

           Input type                 S-TMR, HOLD, RESET, ZERO, BANK1, BANK2,                                                   TIMING

                                                            BANK4

Contact                            ON: 1 kΩ max., OFF: 100 kΩ min.                                    ---

No-contact                         ON residual voltage: 2 V max.                                      ON residual voltage: 3 V max.

                                   OFF leakage current: 0.1 mA max.                                   OFF leakage current: 1.5 mA max.

                                   Load current: 4 mA max.                                            Load current: 17 mA max.

                                   Maximum applied voltage: 30 VDC max.                               Maximum applied voltage: 30 VDC max.

■ Output Ratings

Contact Output                                                                           Transistor Output

Item                   Resistive loads             Inductive loads                       Maximum load voltage           24 VDC

                    (250 VAC, cosφ=1;            (250 VAC, closed                        Maximum load current           50 mA

                    30 VDC, L/R=0 ms)            circuit, cosφ=0.4;

                                                 30 VDC, L/R=7 ms)                       Leakage current                100 μA max.

Rated load          5 A at 250 VAC                 1 A at 250 VAC

                    5 A at 30 VDC                  1 A at 30 VDC

Mechanical life     5,000,000 operations

expectancy

Electrical life     100,000 operations

expectancy

Linear Output

              Item                              0 to 20 mA                    4  to  20  mA            0 to 5 V                1 to 5 V              0 to 10 V

Allowable load impedance           500 Ω max.                                                     5 kΩ min.

Resolution                         Approx. 10,000

Output error                       ±0.5%FS                                                        ±0.5%FS (1 V or less: ±0.15 V; not output for 0 V or less)

Serial Communications Output                                                             BCD Output I/O Ratings

            Item                          RS-232C, RS-485                                (Input Signal Logic: Negative)

Communications method          Half duplex                                                        I/O signal name                        Item         Rating

Synchronization method         Start-stop synchronization                                Inputs   REQUEST                       Input signal          No-voltage

Baud rate                      9,600, 19,200, or 38,400 bps                                       HOLD                                                contact input

Transmission code              ASCII                                                              MAX                           Input current for     10 mA

                                                                                                  MIN                           no-voltage input

Data length                    7 bits or 8 bits                                                   RESET                         Signal   ON voltage   1.5 V max.

Stop bit length                2 bits or 1 bit                                                                                  level    OFF voltage  3 V min.

Error detection                Vertical parity and FCS                                   Outputs  DATA                          Maximum load          24 VDC

Parity check                   Odd, even                                                          POLARITY                      voltage

                                                                                                  OVER                          Maximum load          10 mA

Note: For details on serial and DeviceNet communications,           refer to                      DATA VALID                    current

the        Digital  Indicator  K3HB   Communications        User's  Manual                        RUN                           Leakage current       100 μA max.

(Cat.No. N129).

                                                                                                  HH                            Maximum load          24 VDC

                                                                                                  H                             voltage

                                                                                                  PASS                          Maximum load          50 mA

                                                                                                  L                             current

                                                                                                  LL                            Leakage current       100 μA max.

                                                                                         Note: For details on serial and DeviceNet communications, refer to

                                                                                             the  Digital    Indicator  K3HB   Communications        User's  Manual

                                                                                             (Cat.No. N129).

                                                                                                                                                                     5
                                                                                                                                                     K3HB-H

DeviceNet Communications

Communications protocol                                           Conforms to DeviceNet

Supported communi-               Remote I/O communications        Master-Slave connection (polling, bit-strobe, COS, cyclic)

cations                                                           Conforms to DeviceNet communications standards.

                                 I/O allocations                  Allocate any I/O data using the Configurator.

                                                                  Allocate any data, such as DeviceNet-specific parameters and variable area for Digital

                                                                  Indicators.

                                                                  Input area: 2 blocks, 60 words max.

                                                                  Output area: 1 block, 29 words max.

                                                                  (The first word in the area is always allocated for the Output Execution Enabled Flags.)

                                 Message communications           Explicit message communications

                                                                  CompoWay/F communications commands can be executed (using explicit message

                                                                  communications)

Connection methods                                                Combination of multi-drop and T-branch connections (for trunk and drop lines)

Baud rate                                                         DeviceNet: 500, 250, or 125 Kbps (automatic follow-up)

Communications media                                              Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line)

Communications distance

                                                                               Baud rate                    Network length  Drop line length  Total drop line

                                                                                                            (max.)              (max.)        length (max.)

                                                                           500 Kbps              100 m (100 m)              6m                39 m

                                                                           250 Kbps              100 m                      6m                78 m

                                                                                                 (250 m)

                                                                           125 Kbps              100 m                      6m                156 m

                                                                                                 (500 m)

                                                                           The values in parentheses are for Thick Cable.

Communications power supply                                       24-VDC DeviceNet power supply

Allowable voltage fluctuation range                               11 to 25-VDC DeviceNet power supply

Current consumption                                               50 mA max. (24 VDC)

Maximum number of nodes                                           64 (DeviceNet Configurator is counted as one node when connected)

Maximum number of slaves                                          63

Error control checks                                              CRC errors

DeviceNet power supply                                            Supplied from DeviceNet communications connector

■ Internal Block Diagram

Analog input   Input             ADC                              Keys

               circuit

                                 EEP-ROM                          Indications

               BCD

BCD I/O        • Input circuit   Drive                            Drive                                     Transistor

               • Output circuit  circuit                          circuit                                   output

               • Transistor

               output circuit                     Micro-

Event input                                       computer        Drive

               Digital input     Waveform                                      X                            Relay output

               circuit           shaping circuit                  circuit

Linear output  Linear output     Drive                            Drive               DeviceNet             DeviceNet

               circuit           circuit                          circuit             circuit

Sensor power                                                      Drive               Communi-

supply         Filter                                             circuit             cations               Communications

                                                                                      driver

               VO                                 VDD                                     VCOM

                                 Power supply circuit (isolated)                  VO  DC-DC

                                                                                      Converter (isolated)

                                 Power supply

                                                                                                                                                               6
                                                                                                                                                                                     K3HB-H

■ Power Supply Derating Curve for Sensor (Reference Value)

With 12 V                                                          With 10 V

Max. current (mA)                                                  Max. current (mA)

   140                                                                 140

                                             1                                                                                 1

   120                                                                 120

   100                                                                 100

   80                                                                  80

   60                                                                  60

   40                                                                  40

   20                                                                  20

   0                                                                        0

   −20     −10     0  10       20  30    40            50  60               −20      −10      0        10     20      30  40      50  60

                                   Ambient temperature (°C)                                                       Ambient temperature (°C)

Note: 1.  The above values are for standard mounting. The derating curve differs depending on the mounting conditions.

   2.     Do not use the Sensor outside of the derating area (i.e., do not use it in the area labeled A in the above graphics).                                          Doing so may occa-

          sionally cause deterioration or damage to internal components.

■  Component Names and Functions

   Max/Min status indicator                                                                                                                          PV display

   Turns ON when the maximum value or minimum value is                                                                                Displays PVs, maximum values,

   displayed in the RUN level.                                                                                                        minimum values, parameter

                                                                                                                                      names, and error names.

           Level/bank display                                                                                                                        Position meter

          In RUN level, displays the bank if the bank function is                                                                     Displays the position of the PV with

          ON. (Turns OFF if the bank function is OFF.)                                                                                respect to a desired scale.

          In other levels, displays the current level.

          Comparative output                                                                                                                         SV display

           status indicators                                                                                                          Displays SV and monitor values.

                                                                   HH  Max

          Display the status of comparative outputs.               H   Min

                                                                   P   L

                                                                   L   T-ZR    CMW        TG  HH    H

                                                                   LL  Zero    Hold       T   LL    L

           Status indicators                                                                                                                SV display status indicators

                               Function                            MAX/MIN       LEVEL        MODE     SHIFT      UP                        Display  Function

          Display

          Hold     Turns ON/OFF when hold input turns                                                                                       TG       Turns ON when the timing signal turns

                   ON/OFF.                                                                                                                           ON. Otherwise OFF.

                                                                                                                                            HH, H,   In RUN level, turn ON when the

                                                                                                                                            L, LL    comparative set values HH, H, L, and

                                                                                                                                                     LL are displayed.

           MAX/MIN Key                                 LEVEL Key                     MODE Key                             SHIFT Key                                     UP Key

          Used to switch the             Used to switch level.              Used to switch the                        Used to change                 When changing a set value,

          display between the                                               parameters displayed.                     parameter settings.            this key is used to change

          PV, maximum value,                                                                                          When changing a set            the actual value.

          and minimum value and                                                                                       value, this key is used

          to reset the maximum                                                                                        to move along the

          and minimum values.                                                                                         digits.

                                                                                                                                                                                             7
                                                                                                                                                                                                                                                    K3HB-H

■ BCD Output Timing Chart

A REQUEST signal from a Programmable Controller or other external                                                              device is required to read BCD data.

Single Sampling Data Output                                                                                                                 Continuous Data Output

                                    20-ms pulse min. (50 ms max.)                                                                           REQ.

REQ.                                                                                                                                        MAX.MIN.

MAX.MIN.

                                                                                                                                            DATA   All data "High"                    Data 1                                  Data 2

DATA               All data "High"         Data                                   All data "High"

                                                                                                                                            DATA

DATA                                                                                                                                        VALID

VALID                                                                                                                                                                                 40 ms                                       40 ms

                          Approx.          40 ms                                                                                                               Approx.                                 24 ms                                                   24 ms

                                    30 ms                              16 ms                                                                                   30 ms                        64 ms                                       64 ms

The data is set in approximately 30 ms from the rising edge of the                                                                          Measurement data is output every 64 ms while the REQUEST signal

REQUEST signal and the DATA VALID signal is output.                                                                                         remains ON.

When reading the data from a Programmable Controller, start                                                                                 Note: If HOLD is executed when switching between data 1 and data

reading the data when the DATA VALID signal turns ON.                                                                                             2, either data 1 or data 2 is output depending on the timing of

The DATA VALID signal will turn OFF 40 ms later, and the data will                                                                                the hold signal. The data will not go LOW.

turn OFF 16 ms after that.

                                                                              REQ. (1)

      K3HB

      (1)

                                           Programmable                       REQ. (2)

                                           Controller

      K3HB                                                                    REQ. (3)

      (2)

                                    DATA (including POL and

                                    OVER) and DATA VALID can

                                    be used in a wired OR.                    DATA                               (1)                               (2)                           (3)

      K3HB                          RUN, HH, H, PASS, L, and

      (3)                           LL are always output, with or

                                    without a REQUEST signal.                 DATA

                                    Do not used a wired OR                    VALID

                                    connect for these signals.                                                                 (See note.)                     (See note.)                (See note.)

                                                                                        Note:  Leave                       20  ms min. between    DATA VALID turning        OFF  and the  REQUEST      signal.

Programmable Controller Connection Example                                                                                                  Display            Unit         Connection Example

Digital Indicator                                               SYSMAC Programmable Controller                                              Digital Indicator

                          Connector pin No. (See note.)         DC Input Unit                                                                                               Connector pin No. (See note.)

                          1.COMMON                       COM                                                                                                                1.COMMON

                          2.1                               IN                                                                                                              2.1

                          3.2                               IN                                                                                                              3.2

                          4.4       10°                                                        Internal circuit                                                                  10°

                                                            IN                                                                                                              4.4

                          5.8                               IN                                                                                                              5.8

                          23.DATA VALID                                                                                                                                     23.DATA VALID

                          24.RUN                            IN                                                                                                              24.RUN

                                                            IN                                                                                                                                         To  101

                                                                                                                                                                                             To 102

                          25.COMMON                             Transistor Output Unit                                                                                      25.COMMON

                                                         OUT                                                                                                                                  Short-

                          26.REQUEST                                                                                                                                        26.REQUEST        circuit

+5 V               240 Ω                                                             circuit                     circuit                    +5 V               240 Ω

            240 Ω                                                                                                                                       240 Ω

                          30.RESET                       OUT                         Internal                    Internal                                                   30.RESET

                   240 Ω                                                                                                                                       240 Ω                                   V   O  D  C  B  A  DP  LE  V  O  D  C  B  A  DP  LE  V  O  D  C  B  A  DP  LE  V  O

            240 Ω         31.POLARITY                    COM                                                                                            240 Ω               31.POLARITY                         8                       8                         8                   SEC

                          (+/− polarity)                 (0 V)                                                                                                              (+/− polarity)

                                                       24 VDC                                                                                                                                                             M7E-01D@N2, 01H@N2

                                                                   +24 V                                                                                                                                               

                                                                          DC power

                                                                   0V     supply

                                                                                               Note:             The BCD output connector pin number is the D-sub connector pin number when

                                                                                                                 the BCD Output Cable (sold separately) is connected. This number differs from

                                                                                                                 the pin number for the Digital Indicator narrow pitch connector (manufactured by

                                                                                                                 Honda Tsushin Kogyo Co., Ltd.).

            Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator:

            K3HB-S/-X/-V/-H Digital Indicator User's Manual (Cat. No. N128)

            The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp

                                                                                                                                                                                                                                                                                            8
                                                                                                                                                                                                                                                          K3HB-H

■ Connections

Terminal Arrangement

Note: Insulation is used between signal                                                                                      input,  event  input,      output,     and  power   supply     terminals.

                                                                                                                                                                                       A             B         C  D                      E

A Operating Power Supply                                                                                                                                                  1

                                                                                                                                                                          2

                        100 to 240 VAC                                                                                                                                    3

                                24 VAC/ VDC                                                                                                                               4

                                                  A1                                                                                                                      5

                                                                                                                                                                          6

                                                  A2

*Check the required power supply type.

B Sensor Power Supply/Output

Sensor power supply +                                                                                                        C       Relays, Transistors, BCD and DeviceNet

                        PASS output

                                                          B1

                                        PASS              B2                                                                         Relay Outputs               Relay Outputs             Transistor Outputs  DeviceNet Connector (Included)

                                                                                                                                                                                                             

                                                          B3                                                                                                                                    NPN     PNP

                                                  N/C     B4  Sensor power supply                                                           C1           HH         C1                 HH   C1                                           5

        100 mA                  80 mA                                                                                                       C2                      C2                      C2                                           4

                                                  +                                                                                  H                           H                     H                                                 3

                                                          B5

        10 VDC                  12 VDC                                                                                                      C3           COM        C3                PASS  C3                                           2

                                                          B6                                                                                                                                                                             1

                                                  −                                                                                         C4                   L  C4                 L    C4


CPB>                            CPA>                                                                                                 L      C5           LL                            LL   C5                    2: CAN L (Communications cable: Blue)
                Sensor power supply +
                                                                                                                                                                                                                  3: Shield
                                                                                                                                            C6           COM        C6                COM   C6
                                linear output                                                                                                                                                                     4: CAN H (Communications cable: White)

                                                              +                                                                                                                                                   5: V+ (Power supply cable: Red)

                                                                                   B1                                                                                                                             Applicable Connector:

0-5/1-5/        N/C                     0-5/1-5/  N/C                                                                                                                                                             HR31-5.08P-5SC (01)

0-10 V                                  0-10 V                                     B2                                                                                                                             (HIROSE ELECTRIC CO., LTD.)

                                                              −                                                                         BCD (NPN Open Collector): BCD                                             * Attach the provided crimp terminals.

                                                              +                    B3

N/C             0-20/                   N/C       0-20/                                                 Sensor power supply             Applicable Connector (Sold separately)

                4-20 mA                           4-20 mA                          B4                                                   HDR-E50MAG1

100 mA                  100 mA          80 mA     80 mA       −                                                                         (HONDA TSUSHIN KOGYO CO., LTD.)

                                                              +                    B5                                                   Special Cable (Sold separately)

10 VDC                  10 VDC          12 VDC    12 VDC                                                                                K32-BCD (OMRON)

                                                              −                    B6                                                   (HDR-E50MAG1 with 0.3-m cable)


L2B>            L1B>            L2A>              L1A>                                                                                  The BCD COMMON is shared.

                Sensor power supply                                                                                                     The pins indicated in the above diagram

                                                                                                                                        as blank (white) boxes have been removed.

                                                              B1                                                                        *Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet.

                                                              B2

                                                  N/C                                                                                Contact output                                         Transistor Output

                                                              B3                   Sensor power supply                                                                                      (NPN Open Collector)

                100 mA                                        B4

                                        80 mA             +   B5                                                                                    5V

                10 VDC                  12 VDC            −   B6                                                                                                                   HH                                                          HH

                                                                                                                                                                     H                                                           H

                Sensor power supply +                                                                                                                                              L                                                           L

                                communications                                                                                                                                     LL                                                          LL

B (+)                   SD              B (+)     SD                               B1                                                                                              PASS                                                        PASS

A (−)                   RD              A (−)     RD                               B2

B (+)                   SG              B (+)     SG                               B3                   Sensor power supply

A (−)                   N/C             A (−)     N/C                              B4                                                                                    Safety Standards Conformance

100 mA                  100 mA          80 mA     80 mA       +                    B5

10 VDC                  10 VDC          12 VDC    12 VDC                                                                             •      Always use a EN/IEC-compliant power supply with reinforced insulation or

                                                              −                    B6                                                       double insulation for the DeviceNet power supply.

RS-485          RS-232C                 RS-485    RS-232C                                                                            •      The product must be used indoors for the above applicable standards to


FLK3B>          FLK1B>                  FLK3A>    FLK1A>                                                                                    apply.

                                                                                                                                     •      The K3HB-XVA@@ complies with UL standards when the applied input

                                                                                                                                            voltage is within the range 0 to 150 VAC.

                                                                                                                                                                                                                                                                  9
                                                                                                                                                                               K3HB-H

                               E Analog Input

                               Process Indicator                Weighing Indicator                      Temperature Indicator                  Linear Sensor Indicator

                               K3HB-X                                  K3HB-V                                    K3HB-H                                       K3HB-S

                                          AC voltage only

                               E1    N/C     A, B                      E1        N/C                                      E1                                          E1 Input B

                               E2     A      N/C                       E2        A                               N/C      E2                   Current input          E2 Input A

                               E3     B      C                         E3        B                                        E3                                          E3 COM

                               E4     C      D                         E4        C                               A        E4                   Voltage input          E4 Input A

                                                                                                                 Pt   -

                               E5     D      N/C                       E5        D                                        E5                                          E5 Input B

                                                                                                                 B    TC

                               E6 COM        COM                       E6        COM                                  +   E6  COM                             N/C     E6

                                                                                                                 B'

                               D Event Input

                     Models with Terminal Blocks                •      Use terminal pin D6 as the common terminal.

                                                  •      Use NPN open collector or no-voltage contacts for event input.

                                                                       PNP types are also available.

                                     D1  TIMING

                                     D2  S-TMR                                                    12 V                                                                12 V

                                                                S-TMR: D2

                                     D3  HOLD                          HOLD: D3

                                                                RESET: D4                       4.7 kΩ                                 TIMING                     560 Ω

                                     D4  RESET

                                     D5  ZERO*                                                                                                 D1

                                                                                             3.9 kΩ                                                               750 Ω

                                     D6  COM

                            Models with Connectors                               D6                                                            D6

                                                         COM                                                             COM

                     1: TIMING       1          2  2: S-TMR

                     3: HOLD                       4: RESET

                     5: ZERO                       6: COM

                     7: BANK4        9             8: BANK2
                                              10 10: COM
                     9: BANK1

                     • Applicable Connector (Sold separately)

                            XG4M-1030 (OMRON)

                     • Special Cable (Sold separately)

                            K32-DICN (OMRON)

                            (XG4M-1030 with 3 m cable)

                     * Excluding the K3HB-H

BCD Output Cable

Model                                                           Shape                                                                              Pin  arrangement

K32-BCD                                                                               Connected device end                             COMMON                 1

                     K3HB end                                                       (PLC, display device, etc.)                                         1     2   20  4   104

                                                                                                                                                        2     3   21  8

                                                                                                                                                   100  4     4   22           OVER

                                                                                                                                                        8     5   23           DATA VALID

                                                                                                                                                        1     6   24           RUN

                                                                                                                                                        2     7   25           COMMON

                                                                                                                                                   101  4     8   26           REQUEST

                                                                                                                                                        8     9   27           MAX REQ.

                                                                                                                                                        1     10  28           MIN REQ.

                                                                                                                                                        2     11  29           HOLD

                                                        300 mm                                                                                     102  4     12  30           RESET

                     38 mm                                                            46.5 mm                                                           8     13  31           POLARITY

                                                                                                                                                        1     14  32           HH

             Cover:  HDR-E50LPA5                                       D-sub connector (37-pin female)                                                  2     15  33           H

                     (manufactured by Honda Tsushin Co., Ltd.)         Cover:         17JE-37H-1A (manufactured by DDK)                            103  4     16  34           PASS

             Connector: HDR-E50MAG1                                    Connector: Equivalent to 17JE-13370-02                                           8     17  35           L

                     (manufactured by Honda Tsushin Co., Ltd.)                        (manufactured by DDK)                                             1     18  36           LL

                                                                       Stand:         17L-002A (manufactured by DDK)                               104  2     19  37           COMMON

Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent                       to  17JE-23370-02    (D1) (manufactured by              DDK)

Special Cable (for Event Inputs with 8-pin Connector)

Model                       Appearance                                               Wiring

K32-DICN                                                               Pin No.        Signal name

                                                                                 1           N/C

          9  10                                                                  2    S-TMR

                                                                                 3    HOLD

          1  2                                                                   4    RESET

                               3,000 mm                                          5           −

                Cable marking  (3 m)                                             6    COM

                                                                                 7    BANK4

                                                                                 8    BANK2

                                                                                 9    BANK1

                                                                                 10   COM

                                                                                                                                                                                                 10
                                                                                                                                       K3HB-H

■ Main Functions

Measurement

Timing Hold

Normal                                                                  Sampling Hold

• Continuously performs measurement and always outputs based on         • Holds the measurement at the rising edge of the TIMING signal.

comparative results.

                                                                                      Input                                            Sampling hold value

                   Input

H comparative set value

                                                                        Measurement value

Measurement value

                                                                                                                                               Time

                                                                  Time  TIMING        ON

                                                                               input  OFF

        H output

Peak Hold/Bottom Hold                                                   Peak-to-peak Hold

• Measures the maximum (or minimum) value in a specified period.        • Measures the difference between the maximum and minimum val-

                                                                        ues in a specified period.

        Input             Peak hold value                                             Input

                                                                                                                                       Peak-to-peak value

                                                                                                                                           (b2−a2)

Measurement value                                                                                            (b1−a1)

                                                                        Measurement value              b1                         'b2

                          Bottom hold value                                                        a1           'a2

                          Time                                                                                                             Time

TIMING  ON                                                              TIMING        ON

input OFF                                                                      input OFF

                                                                        Standby Sequence

                                                                        Turns  the    comparative  output  OFF        until  the  measurement       value

                                                                        enters the PASS range.

                                                                        Average Processing

                                                                        Average processing of input signals with extreme changes or noise

                                                                        smooths out the display and makes control stable.

                                                                        Previous Average Value Comparison

                                                                        Slight changes can   be removed      from     input  signals   to  detect   only

                                                                        extreme changes.

                                                                        Temperature Input    Shift

                                                                        Shifts the temperature input value.

                                                                                                                                                            11
                                                                                                                                          K3HB-H

■ Input Compensation/Display

Zero-trimming                                                                             Display Value Selection

Compensates       for  mild   fluctuations     in  input   signals  due  to      factors  The current display value can be selected from the present value, the

such as sensor temperature drift, based on OK (PASS) data at mea-                         maximum value, and the minimum value.

surement. (This function can be used with sampling hold, peak hold,                       Step Value

or bottom hold.)

Zero-limit                                                                                It is possible to specify (i.e., restrict) the values that the smallest dis-

                                                                                          played digit can change by. For example, if the setting is 2, the small-

Changes the display value to 0 for input values less than the set                         est digit will only take the values 0, 2, 4, 6, or 8 and if the setting is 5,

value. It is enabled in normal mode only. (This function can be used,                     it will only take the values 0 or 5. If the setting is 10, it will only take

for example, to stop negative values being displayed or to eliminate                      the value of 0.

flickering and minor inconsistencies near 0.)                                             Interruption Memory

                       Display

                                                                                          •  The minimum and maximum values when the power supply is

                                                                                             turned OFF can be saved if interruption memory is turned ON.

                                                                                          •  If interruption memory is ON, the maximum and minimum values

                  Zero-limit                                                                 after the last resetting will be displayed.

                  setting                                                                 •  If interruption memory is OFF, the maximum and minimum values

                                                                                             will be displayed after the power supply is turned ON (or after the

                                                           Input                             reset input is performed).

Display Refresh Period

The display refresh period can be lengthened to reduce flickering

and thereby make the display easier to read.

Display Color Selection

Values can be displayed in either red or green. With comparative out-

put models, the display color can also be set to change according to

the status of comparative outputs (e.g., green to red or red to green).

Example) Setting: grn-r

                                                           Red

                                                                H   110.01

Comparative set value H                                                  110.00

                                               Green

                                            P  100.05

Comparative set value L                            110.00

                  L    99.87

                              110.00

                                      Red

                                                                                                                                                                         12
                                                                                                                                                                                    K3HB-H

■ Output

Comparative Output Pattern                                                                                 Hysteresis

The output pattern for comparative outputs can be selected. In addi-                                  Prevents    comparative            output     chattering  when   the          measurement

tion to high/low comparison with set values, output based on level                                    value fluctuates slightly near the set value.

changes is also possible. (Use the type of output pattern appropriate

for the application.)                                                                                          Example: Comparative Output Pattern (Standard Output)

                                                                                                           Comparative set value H                  Hysteresis

Comparative    Standard Output  Measurement                       Level Output       Measurement                                                                Hysteresis

set value HH                    value        Comparative                             value

Comparative                     Higher       set value HH                                  Higher          Comparative set value L

set value H                                  Comparative

                                             set value H

Comparative                                  Comparative

set value L                     Lower        set value L                                   Lower               Comparative output H

Comparative                                  Comparative

set value LL                                 set value LL

Output HH                       ON           Output HH                               ON                          Comparative output L

Output H                        OFF          Output H                                OFF

Output PASS                                  Output PASS                                                   Startup Compensation Timer

Output L                                     Output L

Output LL                                    Output LL

                                                                                                      Measurement can be stopped for a set time using external input.

Comparative    Zone Output      Measurement

set value HH                    value                                                                                         Input

Comparative                     Higher

set value H                                                                                                H comparative set value

Comparative

set value L                     Lower

Comparative

set value LL

Output HH                       ON

Output H                        OFF                                                                                                                                                          Time

Output PASS

Output L                                                                                                                 H output          Startup

                                                                                                                                           compensation

Output LL                                                                                                                H input           time set time

Output Logic

                                                                                                           PASS Output Change

Reverses the output operation of comparative outputs for compara-

tive results.                                                                                         Comparative results other than PASS and                   error  signals      can  be  output

                                                                                                      from the PASS output terminal.

■ Dimensions

                                                           101.2                Terminal cover (included)

                                                           91

                                                                                            Character Size for Main Display (mm)                    Panel Cutout Dimensions

                                                                                                   PV display          SV display                               120 min. *2

                                                                                                           14.2                     4.9

                                                                                100

                                                                                    (112)                                3.5

                                                                                                      7.6                                  75 min.

                                                                                                                                                    92+00.8

                                                                                12                                                                                     45+00.6

                                                                                     1.3                   95 *1

                                                           96                                      2

                                                                                                                                           *2. Leave a distance of at least 140 mm when using

                                                                                                                                                    the Watertight Cover Y92A-49N.

                                                                                48                                                   44.8

                                                                                                                                           Note: Mounting Recommended Panel

                                                                                                                                                    Thickness 1 to 8 mm.

                                                                                                                                                    Mount the product horizontally.

                                                                                            *1. DeviceNet models: 97 mm

                                                                                            Terminal: M3, Terminal Cover: Accessory

                                                                                                                                                                                                     13
                                                                                                                        K3HB-H

■ Wiring Precautions                                                     ■ Mounting Method

• For terminal blocks, use the crimp terminals suitable for M3 screws.   1.  Insert the K3HB into the mounting cutout in the panel.

• Tighten the terminal screws to the recommended tightening torque       2.  Insert watertight packing around the Unit to make the   mounting

of approx. 0.5 N⋅m.                                                          watertight.

• To prevent inductive noise, separate the wiring for signal lines from                        Watertight

that for power lines.                                                                          packing

Wiring

• Use the crimp terminals suitable for M3 screws shown below.

                                          5.8 mm max.

                                          5.8 mm max.                    3.  Insert the adapter into the grooves on the left and right sides of

                                                                             the rear case and push until it reaches the panel and is fixed in

Unit Stickers                                                                place.

• Select the appropriate units from the unit sticker sheets provided                                       Adapter

and attach the sticker to the Indicator.

                                                                         ■ LCD Field of Vision

                                                                         The K3HB is designed to have the best visibility at the angles shown

Note: When using for meters, such as weighing meters, use the units      in the following diagram.

specified by regulations on weights and measures.

                                                                                     10°

                                                                                          30°

■ Watertight Cover                                     ■ Rubber          Packing

Y92A-49N                                               K32-P1

                                                                             If the rubber packing is lost or damaged, it can be ordered

                                                                             using the following model number: K32-P1.

                                                                             (Depending on the operating environment, deterioration,

                                                                             contraction, or hardening of the rubber packing may occur

                                                                             and so, in order to ensure the level of waterproofing speci-

                                                                             fied in NEMA4, periodic replacement is recommended.)

                                                                             Note: Rubber packing is provided with the Controller.

          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                       In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                 14
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2014.9

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Omron:

K33-A  K33-FLK3A

小广播

K33-A器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved