电子工程世界电子工程世界电子工程世界

产品描述

搜索

HDO4K-SENTbus-D

器件型号:HDO4K-SENTbus-D
器件类别:热门应用    测试测量   
厂商名称:Teledyne LeCroy
厂商官网:http://teledynelecroy.com/protocolanalyzer/
下载文档

器件描述

Test Accessories - Other Mercury Filled Parts OPT FOR HDO 4000

参数
产品属性属性值
产品种类:
Product Category:
Test Accessories - Other
制造商:
Manufacturer:
Teledyne LeCroy
RoHS:YES
产品:
Product:
Accessories
Equipment Type:Test Equipment
Accessory Type:Software - SENTbus D
商标:
Brand:
Teledyne LeCroy
Display Type:None
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
HDO4000 HDO4096

HDO4K-SENTbus-D器件文档内容

      HDO4000

      High Definition

      Oscilloscopes

      200 MHz – 1 GHz

Key Features

•  12-bit ADC resolution, up to        Combining Teledyne LeCroy’s HD4096 high definition technology, with

   15-bit with enhanced resolution      long memory, a compact form factor, 12.1” wide touch screen display,

•  200 MHz, 350 MHz, 500 MHz,          powerful debug tools, and mixed signal capability, the HDO4000 is the

   1 GHz bandwidths                     ideal oscilloscope for precise measurements and quick debug. Tools

                                        such as WaveScan Search and Find, LabNotebook Report Generator,

•  Long Memory – up to 50 Mpts         and History Mode help identify and isolate problems for faster

•  12.1” touch screen display          troubleshooting.

•  Multi-language User Interface       HD4096 Technology                         Large 12.1” Touch Screen

                                        HD4096 high definition technology         Navigating complicated user interfaces

•  WaveScan – Search and Find          consists of high sample rate 12-          is a thing of the past thanks to the large

•  LabNotebook Documentation           bit ADCs, high signal-to-noise input      touch screen display of the HDO4000.

   and Report Generation                amplifiers and a low-noise system         The user interface was designed for

                                        architecture. This technology enables     touch screens which makes navigating

•  History Mode                        high definition oscilloscopes to capture  the HDO4000 extremely intuitive. Every

•  Spectrum Analyzer Mode              and display signals of up to 1 GHz with   aspect of the interface is touchable

                                        high sample rate and 16 times more        making channel, timebase and trigger

•  Power Analysis Software             resolution than other oscilloscopes.      settings only one touch away.

•  Serial Data Trigger and Decode      Long Memory                               Compact Form Factor

•  16 Digital Channels with 1.25 GS/s  With up to 50 Mpts of memory the          The HDO4000 builds upon Teledyne

   – Analog and Digital                 HDO4000 High Definition Oscilloscopes     LeCroy’s history of “Large Screen,

             Cross-Pattern Triggering          can capture large amounts of data         Small Footprint” with its 12.1” wide

   – Digital Pattern Search and Find    with more precision than other            touch screen display and 5” depth.

   – Analog and Digital Timing          oscilloscopes. The 2.5 GS/s, 50 Mpts      Additionally, the innovative rotating,

             Measurements                      architecture provides the ability to      tilting feet enable the HDO4000 to be

   – Activity Indicators                capture a fast transient or a long        placed in 4 different viewing positions

                                        acquisition.                              ensuring optimal viewing no matter

                                                                                  where it is being positioned in the lab.
HD4096 HIGH DEFINITION TECHNOLOGY

                                                HD4096 high definition technology consists of high

                                                sample rate 12-bit ADCs, high signal-to-noise ratio

                                                amplifiers and a low-noise system architecture. This

                                                technology enables high definition oscilloscopes to

                                                capture and display signals of up to 1 GHz with high

   High Signal                   High Sample    sample rate and 16 times more resolution than other

   to Noise Input                Rate 12-bit    oscilloscopes.

   Amplifiers                            ADC’s

                                                Oscilloscopes with HD4096 technology have higher resolution

                                                and measurement precision than 8-bit alternatives. The high

                                                sample rate 12-bit ADCs provide high resolution sampling at

                   Low Noise                    up to 2.5 GS/s. The high performance input amplifiers deliver

                   System                       phenomenal signal fidelity with a 55 dB signal-to-noise ratio and

                                                provide a pristine signal to the ADC to be digitized. The low-noise

                   Architecture                 signal architecture ensures that nothing interferes with the

                                                captured signal and the oscilloscope displays a waveform that

                                                accurately represents the signals from the device under test.

16x Closer to Perfect

   8-bit                                        12-bit

                                                                                                          Digitized Waveform

                                                                                                          Signal from

                     Quantization Error                                                                   Device Under Test

16x More Resolution

12-bits of vertical resolution provides sixteen times more resolution than 8-bits. The 4096 discrete

levels reduce the quantization error. Signals captured with lower resolution oscilloscopes have a higher

level of quantization error resulting in less accurate waveforms on the display. Signals captured on an

oscilloscope with 12-bit HD4096 technology are accurately displayed with minimal quantization error.

2
DEBUG IN HIGH DEFINITION WITH HD4096

                                         Oscilloscopes with HD4096 have a variety of benefits that

                                         allow the user to debug in high definition. Waveforms

                                         displayed by high definition oscilloscopes are cleaner and

                                         crisper. More signal details can be seen and measured; these

                                         measurements are made with unmatched precision resulting

                                         in better test results and shorter debug time.

Clean, Crisp Waveforms                   More Signal Details                                            Unmatched

When compared to waveforms captured      Signal details often lost in the noise                         Measurement Precision

and displayed by 8-bit oscilloscopes,    are clearly visible and easy to distin-                        Precise measurements are critical for

waveforms captured with HD4096           guish when captured on oscilloscopes                           effective debug and analysis. HD4096

technology are dramatically crisper and  with HD4096. Details which were                                enables oscilloscopes to deliver

cleaner. Oscilloscopes with HD4096       previously difficult to even see can now                       unmatched measurement precision to

acquire waveforms at high resolution,    be easily seen and measured. Using the                         improve testing capabilities and provide

high sample rate and low noise to        oscilloscope zoom capabilities gives                           better results.

display the most accurate waveforms.     an even closer look at the details for

                                         unparalleled insight to the signals

                                         on screen.

8-bit  A                                                      12-bit                                 A

          B                              C                                                              B                C

A      Clean, Crisp Waveforms | Thin traces show the actual waveform with minimal noise interference

B      More Signal Details | Waveform details lost on an 8-bit oscilloscope can now be clearly seen

C      Unmatched Measurement Precision | Measurements are more precise and not affected by quantization noise

                                                                                                                                                  3
HDO4000 - HIGH DEFINITION                               OSCILLOSCOPE

HDO4000 High Definition Oscilloscopes

combine Teledyne LeCroy’s HD4096 high

definition technology with long memory,

powerful debug tools and mixed signal

capability in a compact form factor with a              2

12.1” touch screen display.

   1.  Only 13 cm (5”) Deep – The most

       space-efficient oscilloscope for your

       bench from 200 MHz to 1 GHz

   2.  12.1” Widescreen (16 x 9) high resolution

       WXGA color touch screen display. The most

       time-efficient user interface is even easier to

       use with a built-in stylus

   3.  Local language user interface – Select from

       10 language preferences. Add a front panel

       overlay with your local language

   4.  “Push” Knobs – All knobs have push

       functionality that provides shortcuts to

       common actions such as Set to Variable, Find

       Trigger Level, Zero Offset, and Zero Delay

   5.  Waveform Control Knobs – Control channel,

       zoom, math and memory traces with the

       multiplexed vertical and horizontal knobs

                                         1

       8

                                                   10

4
                   6.    Dedicated Cursor Knob – Select type of cursor,

                         position them on your signal, and read values

                         without ever opening a menu

                   7.    Dedicated buttons to quickly access popular

3                        debug tools.

                   8.    Easy connectivity with two convenient USB ports

                         on the front, two on the side

                   9.    Mixed Signal Capability - Debug complex

         4               embedded designs with integrated 16 channel

                         mixed signal capability

                   10.  Rotating and Tilting Feet provide 4 different

                         viewing positions

                   11.   Auxiliary Output and Reference Clock

         5               Input/Output connectors for connecting to

   6                     other equipment

                   12.   USBTMC (Test and Measurement Class) port

                         simplifies programming

            7

                8

      9

                                       11 12

            10     Document and Share:

                   • Quickly save all files with LabNotebook

                   • Create custom reports with LabNotebook

                   • Save to internal hard disk or network drive

                   • Print to a USB printer

                   • Save to USB memory stick

                   • Connect with LAN or GPIB

                   • View data on a PC with free WaveStudio utility

                                                                           5
POWERFUL MIXED SIGNAL CAPABILITIES

   Teledyne LeCroy’s HDO4000-MS High Definition mixed signal oscilloscope combines the high

   definition analog channels of the HDO4000 with the flexibility of 16 digital inputs. In addition,

   the many triggering and decoding options turn the HDO4000-MS into an all-in-one analog,

   digital, serial debug machine.

   High-performance 16 Channel               Extensive Triggering                       Advanced Digital Debug Tools

   Mixed Signal Capability                   Flexible analog and digital cross-pattern  Using the powerful parallel pattern

   With embedded systems growing             triggering across all 20 channels          search capability of WaveScan, patterns

   more complex, powerful mixed signal       provides the ability to quickly identify   across many digital lines can be iso-

   debug capabilities are an essential part  and isolate problems in an embedded        lated and analyzed. Identified patterns

   of modern oscilloscopes. The 16 inte-     system. Event triggering can be con-       are presented in a table with timestamp

   grated digital channels and set of tools  figured to arm on an analog signal and     information and enables quick search-

   designed to view, measure and analyze     trigger on a digital pattern.              ing for each pattern occurrence.

   analog and digital signals enable fast

   debugging of mixed signal designs.                                                   Use a variety of many timing

                                                                                        parameters to measure and analyze the

                                                                                        characteristics of digital busses.

                                                                                        Powerful tools like trends, statistics

                                                                                        and histicons provide additional insight

                                                                                        and help find anomalies.

                                                                                        Quickly see the state of all the digital

                                                                                        lines at the same time using

                                                                                        convenient activity indicators.

6
SERIAL TRIGGER AND DECODE OPTIONS

View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages.

Trigger and Decode                         Table and Search                           Supported Serial Data

The serial data trigger will quickly iso-  To further simplify the debug process      Protocols

late events on a bus eliminating the       all decoded data can be displayed in a     •  I2C, SPI, UART

need to set manual triggers and hoping     table below the waveform grid. Select-     •  CAN, CAN FD, LIN, FlexRay™, SENT

to catch the right information. Trigger    ing an entry in the table with the touch   •  Ethernet 10/100BaseT,

conditions can be entered in binary or     screen will display just that event.          USB 1.0/1.1/2.0, USB 2.0-HSIC

hexadecimal formats and conditional        Additionally, built-in search functional-

trigger capabilities even allow trigger-   ity will find specific decoded values.     •  Audio (I2S, LJ, RJ, TDM)

ing on a range of different events.                                                   •  MIL-STD-1553, ARINC 429,

                                           Serial data messages can be quickly           SpaceWire

Protocol decoding is shown directly        located by searching on address, data      •  MIPI D-PHY, DigRF 3G, DigRF v4

on the waveform with an intuitive,         and other attributes specific to a

color-coded overlay and presented in       particular protocol. Once found, the       •  Manchester, NRZ

binary, hex or ASCII. Decoding on the      specific location containing the

HDO4000 is fast even with long mem-        specified search criteria can be auto-

ory and zooming in to the waveform         matically zoomed to.

shows precise byte by byte decoding.

                                                                                                                           7
   IDENTIFY AND ISOLATE                       PROBLEMS                                FASTER

Touch Screen Simplicity

Configuring the HDO4000 is simple

thanks to the intuitive touch screen

user interface. Everything on the

screen is interactive. To adjust

channel, timebase, or trigger settings,

simply touch the associated

descriptor box and the appropriate

menu is opened. Measurements can

be touched to adjust their settings and

cursors can be positioned precisely

by touching and dragging them to the

proper location. A box can be drawn

around a portion of a waveform to

create a zoom. Even waveform offset

and delay can be adjusted by touching

and dragging the waveform.

WaveScan Advanced Search                      Advanced Math and Measure               Advanced Waveform Capture

WaveScan provides powerful isolation          With many math functions and            with Sequence Mode

capabilities that hardware triggers can’t     measurement parameters available, the   Use Sequence mode to store up to

provide. WaveScan allows searching            HDO4000 can measure and analyze         10,000 triggered events as segments.

analog, digital or parallel bus signal in a   every aspect of analog and digital      This is ideal when capturing fast pulses

single acquisition using more than 20         waveforms. By utilizing HD4096 tech-    in quick succession or when capturing

different criteria. Or, set up a scan condi-  nology, the HDO4000 measures 16         events separated by long time periods.

tion and scan for an event over hours or      times more precisely than traditional   Each segment has a timestamp and

even days.                                    8-bit architectures. Additionally, the  dead-time between triggers is less than

                                              HDO4000 provides statistics, histicons  1 μ­s. Isolate rate events over time by

                                              and trends to show how waveforms        combining with advanced triggers.

                                              change over time.

8
History Mode Waveform Playback

Scroll back in time using History Mode to view previous waveforms and isolate anomalies. Use cursors and

measurement parameters to quickly find the source of problems. History mode is always available with a single

button press, no need to enable this mode and never miss a waveform.

            Go Back in Time to Identify the Source of a Problem

LabNotebook

The LabNotebook feature of HDO4000 provides a report generation tool to save and document all your work. Saving all

displayed waveforms, relevant settings, and screen images is all done through LabNotebook, eliminating the need to navigate

multiple menus to save all these files independently.

            Document Your Work  One-touch Functionality                  Save Your Work

                                                                                                          Recall Jobs

PRINTER                                                                  WAVEFORM

                                                                         V/div                                 FFFLLLAAASSSHHHBBBAAACCCKKK

HARD DRIVE                                                               T/div

                                                                         Memory Length

                                                                         Sample Rate

                                                                         Measurement

USB DRIVE                                                                Math

                                                                         OSCILLOSCOPE SET UP

EMAIL

                                                       LABNOTEBOOK

                                                                         SCREEN DUMP

Easy report generation helps    LabNotebook adds a simple way to         Quickly save all the             Recall your settings

you share your findings and     report your work and save all essential  necessary files with             from any report

communicate important results.  waveforms, settings, and screen images.  LabNotebook in a                      by using the

                                                                         single button press.             Flashback capability.

                                                                                                                                            9
SPECTRUM ANALYZER OPTION

Key Features

•   Spectrum analyzer style controls for

    the oscilloscope

•   Select from six vertical scales

•   Automatically identify frequency

    peaks

•   Display up to 20 markers, with

    interactive table readout of

    frequencies and levels

•   Easily make measurements with

    reference and delta markers

•   Automatically identify and

    mark fundamental frequency

    and harmonics

•                                          Simplify Analysis of FFT Power Spectrum

    Spectrogram shows how spectra

    changes over time in 2D or             Get better insight to the frequency content of any signal with use of the

    3D views                               Spectrum Analyzer mode on the HDO4000. This mode provides a spectrum

                                           analyzer style user interface with controls for start/stop frequency or center

                                           frequency and span. The resolution bandwidth is automatically set for best

                                           analysis or can be manually selected. Vertical Scale can be selected as dBm,

                                           dBV, dBmV, dBuV, Vrms or Arms for proper viewing and analysis while the

                                           unique peak search automatically labels spectral components and presents

                                           frequency and level in an interactive table. Utilize up to 20 markers to automati-

                                           cally identify harmonics and quickly analyze frequency content by making mea-

                                           surements between reference and delta markers. To monitor how the spectrum

                                           changes over time, view the spectrogram which can display a 2D or 3D history

                                           of the frequency content.

                                           Spectrum analyzer style controls simplify waveform analysis in the frequency domain.

10
POWER ANALYZER OPTION

                                                                                       Key Features

                                                                                       •  Automatic switching device

                                                                                          measurements

                                                                                       •  Color coded overlay to identify

                                                                                          power losses

                                                                                       •  Control loop and time domain

                                                                                          response analysis

                                                                                       •  Line power and harmonics tests to

                                                                                          IEC 61000-3-2

                                                                                       •  Total harmonic distortion table

                                                                                          shows frequency contribution

                                                                                       •  B-H Curve shows magnetic

                                                                                          device saturation

Power Analyzer Automates Switching Device Loss Measurements

Quickly measure and analyze the operating characteristics of power conversion

devices and circuits with the Power Analyzer option. Critical power switching de-

vice measurements, control loop modulation analysis, and line power harmonic

testing are all simplified with a dedicated user interface and automatic measure-

ments. Areas of turn-on, turn-off, and conduction loss are all identified with color-     Teledyne LeCroy has a variety of probes

coded waveform overlays for faster analysis.                                              and probing accessories such as high

                                                                                          common mode rejection ratio (CMRR)

Power Analyzer provides quick and easy setup of voltage and current inputs and            differential amplifiers, differential probes,

makes measurements as simple as the push of a button. Tools are provided to               current probes, and deskew fixtures.

help reduce sources of measurement errors and the measurement parameters

provide details of single cycle or average device power losses.

Beyond the advanced power loss measurement capabilities,

the Power Analyzer modulation analysis

capabilities provide insight to

understand control loop response

to critical events such as a power

supply’s soft start performance

or step response to line and load

changes. The Line Power

Analysis tool allows simple and

quick pre-compliance testing

to EN 61000-3-2.

                                                                                                                                         11
PROBES

The right probe is an essential  tool for  accurate  signal  capture  and  Teledyne LeCroy offers an extensive range of probes

to meet virtually every probing  need.

    ZS Series High Impedance                                               The ZS Series probes provide high impedance and an

    Active Probes                                                          extensive set of probe tips and ground accessories to

    ZS2500, ZS1500, ZS1000,                                                handle a wide range of probing scenarios. The high

    ZS2500-QUADPAK,                                                        1 MΩ input resistance and low 0.9 pF input capacitance

    ZS1500-QUADPAK,                                                        mean this probe is ideal for all frequencies. The ZS Series

    ZS1000-QUADPAK                                                         probes provide full system bandwidth for all Teledyne

                                                                           LeCroy oscilloscopes having bandwidths of 1 GHz

                                                                           and lower.

    Differential Probes                                                    High bandwidth, excellent common-mode rejection ratio

    (200 MHz – 1.5 GHz)                                                    (CMRR) and low noise make these ­active differential

    ZD1500, ZD1000,                                                        probes ideal for applications such as automotive

    ZD500, ZD200                                                           development (e.g. FlexRay) and failure analysis, as well

                                                                           as wireless and data communication design. The ProBus

                                                                           interface ­allows sensitivity, offset and common-mode

                                                                           range to be displayed on the oscilloscope screen.

    High Voltage                                                           Low cost active differential probes are intended for

    Differential Probes                                                    measuring higher voltages. The ­differential techniques

    HVD3102, HVD3106,                                                      employed permit measurements to be taken at two points

    HVD3106-6M, HVD3206,                                                   in a circuit without reference to the ground, allowing the

    HVD3605, AP031                                                         oscilloscope to be safely grounded without the use of

                                                                           opto-isolators or isolating transformers.

    High Voltage                                                           High voltage probes are suitable for a wide range of

    Passive Probes                                                         applications where high-voltage measurements must

    HVP120, PPE1.2KV, PPE2KV,                                              be made safely and accurately. There are several fixed

    PPE4KV, PPE5KV, PPE6KV                                                 attenuation probes covering a range from 1 kV to 6 kV

                                                                           and varying transient overvoltage ratings. All of these

                                                                           high voltage probes feature a spring loaded probe tip and

                                                                           a variety of standard accessories to make probing high

                                                                           voltages safe and easy. Additionally, all of the high voltage

                                                                           probe have a probe sense pin to automatically configure

                                                                           the oscilloscope for use with the probe.

    Current Probes                                                         Available current probes reach bandwidths of 100 MHz,

    CP031, CP031A, CP030,                                                  peak currents of 700 A and s­ ensitivities of 10 mA/div. Use

    CP030A, AP015, CP150,                                                  multiple current probes to make measurements on three-

    CP500, DCS015, CA10                                                    phase systems or a single current probe with a voltage

                                                                           probe to make instantaneous power measurements.

                                                                           Teledyne LeCroy current probes enable the design and

                                                                           testing of switching power supplies, motor drives, electric

                                                                           vehicles, and uninterruptible power supplies.

    Probe Adapters                                                         Probe adapters provide simple and easy interface of

    TPA10, TPA10-QUADPAK                                                   third-party probes as well as change between the different

                                                                           Teledyne LeCroy Oscilloscope input and cable types

                                                                           (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending

                                                                           on the adapters, changing between the Teledyne LeCroy

                                                                           Oscilloscope’s input type may have an effect on the overall

                                                                           performance of the channel.

12
SPECIFICATIONS

                                HDO4022                   HDO4024           HDO4032                      HDO4034  HDO4054                      HDO4104

                                HDO4022-MS            HDO4024-MS            HDO4032-MS             HDO4034-MS     HDO4054-MS                   HDO4104-MS

Analog - Vertical

Bandwidth (@ 50Ω)                               200 MHz                                         350 MHz           500 MHz                      1 GHz

Rise time                                     1.75 ns typical                           1 ns typical              700 ps typical               450 ps typical

Input Channels                            2                      4                   2                     4                  4                4

Vertical Resolution             12-bits; up to 15-bits with enhanced resolution (ERES)

Sensitivity                     50 Ω: 1mV/div - 1 V/div; 1 MΩ: 1 mV/div - 10 V/div

DC Gain Accuracy                ±(0.5%) Full Scale, offset at 0 V

BW Limit                        20 MHz, 200 MHz

Maximum Input Voltage           50 Ω: 5 Vrms; 1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz)

Input Coupling                  50 Ω: DC, GND; 1 MΩ: AC, DC, GND

Input Impedance                 50 Ω ±2.0%, 1 MΩ ±2.0% || 15 pF

Offset Range                    50 Ω: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 1 V: ±10 V

                                1 MΩ: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 100 mV: ±16 V,

                                        102 mV - 198 mV: ±80V, 200 mV - 1 V: ±160 V, 1.02 V -10 V: ±400 V

Offset Accuracy                 ±(1.0% of offset value + 0.5%FS + 0.02% of max offset + 1 mV)

Analog - Acquisition

Sample Rate (Single-shot)       2.5 GS/s

Sample Rate (Repetitive)        125 GS/s

Record Length                   Standard -STD: 12.5 Mpts/ch (all channels) 25 Mpts (interleaved)

                                Optional -L:     25 Mpts/ch (all channels), 50 Mpts (interleaved)

Acquisition Modes               Real Time, Roll, RIS (Random Interleaved Sampling),

                                Sequence (Segmented Memory up to 10,000 segments with 1μs intersegment time)

Timebase Range                  200 ps/div - 1.25 ks/div with standard memory (up to 2.5 ks/div with -L memory);

                                RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s

Timebase Accuracy               ±2.5 ppm for 5 to 40C + 1.0 ppm/year from calibration

Digital - Vertical and Acquisition (-MS Models Only)

Input Channels                  16 Digital Channels

Threshold Groupings             Pod 2: D15 - D8, Pod 1: D7 - D0

Threshold Selections            TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined

Maximum Input Voltage           ±30V Peak

Threshold Accuracy              ±(3% of threshold setting + 100mV)

Input Dynamic Range             ±20V

Minimum Input Voltage Swing     400mV

Input Impedance (Flying Leads)  100 kΩ || 5 pF

Maximum Input Frequency         250 MHz

Sample Rate                     1.25 GS/s

Record Length                   Standard STD: 25MS - 16 Channels

                                Optional -L:    50MS - 16 Channels

Minimum Detectable Pulse Width  2 ns

Channel-to-Channel Skew         350ps

User defined threshold range    ±10V in 20mV steps

User defined hysteresis range   100 mV to 1.4 V in 100 mV steps

Trigger System

Modes                           Auto, Normal, Single, Stop

Sources                         Any input channel, External, Ext/10, or line; slope and level unique to each source (except for line trigger)

Coupling                        DC, AC, HFREJ, LFREJ

Pre-trigger Delay               0-100% of full scale

Post-trigger Delay              0-10,000 Divisions

Hold-off                        2ns up to 20s or 1 to 1,000,000,000 events

Internal Trigger Level Range    ±4.1 Divisions

External Trigger Level Range    Ext: ±400mV, Ext/10: ±4V

Trigger Types                   Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV–720p, 1080i, 1080p), Runt, Slew Rate,

                                Interval (signal or Pattern), Dropout, Qualified (State or Edge)

                                                                                                                                                               13
SPECIFICATIONS

                              HDO4022               HDO4024                  HDO4032             HDO4034         HDO4054                 HDO4104

                              HDO4022-MS            HDO4024-MS          HDO4032-MS         HDO4034-MS            HDO4054-MS              HDO4104-MS

Measure, Zoom and Math Tools

Measurement Parameters       Up to 8 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base (Low), Delay,

                             Delta Period @ Level, Delta Time @ Level, Duty, Duty @ Level, Edge @ Level, Fall Time (90%–10%),

                             Fall Time (80%–20%), Frequency, Frequency @ level, Maximum, Mean, Minimum, Overshoot+, Overshoot-,

                             Peak-Peak, Period, Period @ Level, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew,

                             Standard Deviation, Time @ Level, Top (High), Width+, Width-. Statistics and Histicons can be added to any

                             measurement and all measurements can be gated.

Zooming                      Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area.

Math Functions               Functions include Sum, Difference, Product, Ratio, Absolute Value, Averaging (summed and continuous), Derivative, Enve-

                             lope, Enhanced Resolution (to 15-bits), Floor, Integral, Invert, Reciprocal, Rescale (change scale and units), Roof, Square,

                             Square Root, Trend, Zoom and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and FlatTop

                             windows). 2 dual operator math functions may be defined at a time.

Probes

Standard Probes              One PP017 (5mm) per channel                One PP018(5mm) per channel

Probing System               BNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes

Display System

Display Size                 12.1” Wide TFT-LCD Touch-Screen

Display Resolution           1280 x 800

Connectivity

Ethernet Port                (2) 10/100/1000Base-T Ethernet interface (RJ-45 connector)

USB Host Ports               (6) USB Ports Total – (2) Front USB Ports

USB Device Port              (1) USBTMC

GPIB Port (Optional)         Supports IEEE – 488.2

External Monitor Port        Standard 15-pin D-Type SVGA-compatible DB-15 connector, DVI connector and HDMI connector

Remote Control               Via Windows Automation, or via Teledyne LeCroy Remote Command Set

Processor/CPU

Type                         Intel B810 Celeron processor 1.6 GHz or better

Processor Memory             4 GB Standard

Operating System             Windows Embedded Standard 7 64-Bit

Power Requirements

Voltage                      100-240 VAC + 10% at 45-440 Hz; Automatic AC Voltage Selection

Power Consumption (Nominal)  200 W / 200 VA

Max Power Consumption        Max Power Consumption 320 W / 320 VA (with all PC peripherals and active probes connected to 4 channels)

Environmental

Temperature                  Operating: 5 °C to 40 °C; Non-Operating: -20 °C to 60 °C

Humidity                     Operating: 5% to 90% relative humidity (non-condensing) up to +31 °C, Upper limit derates to 50% relative humidity (non-

                             condensing) at +40 °C; Non-Operating: 5% to 95% relative humidity (non-condensing) as tested per

                             MIL-PRF-28800F

Altitude                     Operating: 3,048 m (10,000 ft) max at ≤ 30C; Non-Operating: Up to 12,192 meters (40,000 ft)

Physical

Dimensions (HWD)             11.48”H x 15.72”W x 5.17“D (291.7 mm x 399.4 mm x 131.31 mm)

Weight                       5.86 kg (12.9 lbs)

Regulatory

CE Certification             Low Voltage Directive 2006/95/EC

                             EN 61010-1:2010, EN 61010-2-030:2010

                             EMC Directive 2004/108/EC

                             EN 61326-1:2006, EN61326-2-1:2006

UL and cUL Listing           UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)

                             CAN/CSA C22.2 No.61010-1-12

14
ORDERING INFORMATION

Product Description                                         Product Code         Product Description                                              Product Code

HDO4000 Oscilloscopes                                                            Serial Data Options

200 MHz, 2.5 GS/s, 2 Ch, 12.5 Mpts/Ch 12-bit HD                       HDO4022    ARINC 429 Symbolic Decode Option                 HDO4K-ARINC429bus DSymbolic

Oscilloscope with 12.1" WXGA Touch Display                                       Audiobus Trigger and Decode Option for                     HDO4K-Audiobus TD

200 MHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD                       HDO4024    I2S, LJ, RJ, and TDM

Oscilloscope with 12.1" WXGA Touch Display                                       CAN, LIN and FlexRay Trigger and Decode Option                   HDO4K-AUTO

350 MHz, 2.5 GS/s, 2 Ch, 12.5 Mpts/Ch 12-bit HD                       HDO4032    CAN FD Trigger and Decode Option                    HDO4K-CAN FDbus TD

Oscilloscope with 12.1" WXGA Touch Display                                       CAN Trigger and Decode Option                                 HDO4K-CANbus TD

350 MHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD                       HDO4034    D-PHY Decode Option                                           HDO4K-DPHYbus D

Oscilloscope with 12.1" WXGA Touch Display                                       DigRF 3G Decode Option                              HDO4K-DigRF3Gbus D

500 MHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD                       HDO4054    DigRF v4 Decode Option                                HDO4K-DigRFv4bus D

Oscilloscope with 12.1" WXGA Touch Display                                       ENET Decode Option                                            HDO4K-ENETbus D

1 GHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD                         HDO4104    FlexRay Trigger and Decode Option                   HDO4K-FlexRaybus TD

Oscilloscope with 12.1" WXGA Touch Display                                       I2C, SPI and UART Trigger and Decode Option                      HDO4K-EMB

                                                                                 I2C Bus Trigger and Decode Option                               HDO4K-I2Cbus TD

HDO4000-MS Mixed Signal Oscilloscopes                                            LIN Trigger and Decode Option                                  HDO4K-LINbus TD

200 MHz, 2.5 GS/s, 2+16ch, 12.5 Mpts/Ch 12-bit HD               HDO4022-MS       Manchester Decode Option                            HDO4K-Manchesterbus D

Mixed Signal Oscilloscope w/ 12.1” WXGA Color Display                            MIL-STD-1553 Trigger and Decode Option                           HDO4K-1553 TD

200 MHz, 2.5 GS/s, 4+16ch, 12.5 Mpts/Ch 12-bit HD               HDO4024-MS       NRZ Decode Option                                               HDO4K-NRZbus D

Mixed Signal Oscilloscope w/ 12.1” WXGA Color Display                            SENT Decode Option                                            HDO4K-SENTbus D

350 MHz, 2.5 GS/s, 2+16ch, 12.5 Mpts/Ch 12-bit HD               HDO4032-MS       SPI Bus Trigger and Decode Option                               HDO4K-SPIbus TD

Mixed Signal Oscilloscope w/ 12.1” WXGA Color Display                            SpaceWire Decode Option                             HDO4K-SpaceWirebus D

350 MHz, 2.5 GS/s, 4+16ch, 12.5 Mpts/Ch 12-bit HD               HDO4034-MS       UART and RS-232 Trigger and Decode Option           HDO4K-UART-RS232bus TD

Mixed Signal Oscilloscope w/ 12.1” WXGA Color Display                            USB 2.0 Trigger and Decode Option                             HDO4K-USB2bus TD

500 MHz, 2.5 GS/s, 4+16ch, 12.5 Mpts/Ch 12-bit HD               HDO4054-MS       USB2-HSIC Decode Option                             HDO4K-USB2-HSICbus D

Mixed Signal Oscilloscope w/ 12.1” WXGA Color Display                            Probes and Amplifiers

1 GHz, 2.5 GS/s, 4+16ch, 12.5 Mpts/Ch 12-bit HD                 HDO4104-MS

Mixed Signal Oscilloscope w/ 12.1” WXGA Color Display                            250 MHz Passive Probe 10:1, 10 MΩ                                PP017

                                                                                 500 MHz Passive Probe 10:1, 10 MΩ                                PP018

Included with Standard Configurations (HDO4000 and                               Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 MΩ                         ZS1500-QUADPAK

HDO4000-MS)                                                                      High Impedance Active Probe

÷10 Passive Probe (Total of 1 Per Channel), Getting Started Guide,               Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 MΩ                           ZS1000-QUADPAK

Anti-virus Software (Trial Version), Microsoft Windows Embedded Standard         High Impedance Active Probe

7 P 64-Bit License, Commercial NIST Traceable Calibration with                   200 MHz, 3.5 pF, 1 MΩ Active Differential Probe                  ZD200

Certificate, Power Cable for the Destination Country, Protective Front Cover,    1 GHz, 1.0 pF Active Differential Probe, ±8 V                    ZD1000

3-year Warranty                                                                  1.5 GHz, 1.0 pF Active Differential Probe, ±8 V                  ZD1500

Included with HDO4000-MS                                                         1kV, 25 MHz High Voltage Differential Probe                      HVD3102

16 Channel Digital Leadset, Extra Large Gripper Probe Set (Qty. 22),             1kV, 120 MHz High Voltage Differential Probe                     HVD3106

Ground Extenders (Qty. 20), Flexible Ground Leads (Qty. 5)                       1kV, 80 MHz High Voltage Differential Probe with 6m cable        HVD3106-6M

                                                                                 1 kV, 25 MHz High Voltage Differential Probe with               HVD3102-NOACC

Memory Option                                                                    2 m cable without tip Accessories

25 Mpts/ch (50 Mpts interleaved) memory                               HDO4K-L    1 kV, 120 MHz High Voltage Differential Probe with              HVD3106-NOACC

                                                                                 2 m cable without tip Accessories

Hardware Options                                                                 2kV, 120 MHz High Voltage Differential Probe                     HVD3206

Removable Hard Drive Package (includes                                HDO4K-RHD  6kV, 100 MHz High Voltage Differential Probe                     HVD3605

removable hard drive kit and two hard drives)                                    1,400 V, 100 MHz High-Voltage Differential Probe                 ADP305

Additional Removable Hard Drive                             HDO4K-RHD-02         1,400 V, 20 MHz High-Voltage Differential Probe                  ADP300

General Accessories                                                              1 Ch, 100 MHz Differential Amplifier                             DA1855A

                                                                                 with Precision Voltage Source

External GPIB Accessory                                               USB2-GPIB  30 A; 100 MHz Current Probe – AC/DC; 30 A ;rms 50 Apeak Pulse    CP031

Soft Carrying Case                                          HDO4K-SOFTCASE       30 A; 100 MHz High Sensitivity Current Probe – AC/DC; 30 Arms;   CP031A

Rack Mount Accessory                                                HDO4K-RACK   50 Apeak Pulse

Accessory Pouch                                                 HDO4K-POUCH      30 A; 50 MHz Current Probe – AC/DC; 30 A ;rms 50 Apeak Pulse     CP030

Local Language Overlays                                                          30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 Arms;    CP030A

German Front Panel Overlay                                  HDO4K-FP-GERMAN      50 Apeak Pulse

French Front Panel Overlay                                  HDO4K-FP-FRENCH      30 A; 50 MHz Current Probe – AC/DC; 30 A ;rms 50 Apeak Pulse     AP015

Italian Front Panel Overlay                                 HDO4K-FP-ITALIAN     150 A; 10 MHz Current Probe – AC/DC; 150 A ;rms 500 Apeak Pulse  CP150

Spanish Front Panel Overlay                                 HDO4K-FP-SPANISH     500 A; 2 MHz Current Probe – AC/DC; 500 A ;rms 700 Apeak Pulse   CP500

Japanese Front Panel Overlay                       HDO4K-FP-JAPANESE             Deskew Calibration Source for CP031, CP030 and AP015             DCS015

Korean Front Panel Overlay                                  HDO4K-FP-KOREAN      100:1 400 MHz 50 MΩ 1 kV High-voltage Probe                      HVP120

Chinese (Tr) Front Panel Overlay                   HDO4K-FP-CHNES-TR             10:1/100:1 200/300 MHz, 50 MΩ High-voltage Probe                 PPE1.2KV

                                                                                 600 V/1,2 kV Max. Volt. DC

Chinese (Simp) Front Panel Overlay                          HDO4K-FP-CHNES-SI    100:1 400 MHz 50 MΩ 2 kV High-voltage Probe                      PPE2KV

Russian Front Panel Overlay                                 HDO4K-FP-RUSSIAN     100:1 400 MHz 50 MΩ 4 kV High-voltage Probe                      PPE4KV

Software Options                                                                 1000:1 400 MHz 50 MΩ 5 kV High-voltage Probe                     PPE5KV

Electrical Telecom Mask Test Package                            HDO4K-ET-PMT     1000:1 400 MHz 50 MΩ 6 kV High-voltage Probe                     PPE6KV

Spectrum Analysis Option                                    HDO4K-SPECTRUM

Power Analysis Option                                                 HDO4K-PWR

                                                                                                                                                                  15
Customer Service

Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience

difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes:

• No charge for return shipping

• Long-term 7-year support

• Upgrade to latest software at no charge

                                           1-800-5-LeCroy                                   Local sales offices are located throughout the world.

                                           teledynelecroy.com                               Visit our website to find the most convenient location.

© 2015 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.          hdo4k-ds-16sep15

Product or brand names are trademarks or requested trademarks of their respective holders.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Teledyne LeCroy:

HDO4K-I2Cbus TD  HDO4K-L  PP017-2  HDO4K-Audiobus TD  HDO4K-PWR  HDO4K-SPIbus TD      HDO4K-Audiobus

TDG  HDO4K-DigRF3Gbus D   HDO4K-LINbus TD  HDO4K-DPHYbus D     PP018-1  HDO4K-ET-PMT  HDO4K-

ARINC429BUS Dsymbolic   HDO4034  HDO4024   HDO4K-1553 TD   HDO4K-CANbus TD  HDO4032   HDO4022

HDO4K-USB2bus D  HDO4104  HDO4K-SENTbus D  PP017-1    PP018-2  HDO4K-EMB    HDO4K-UART-RS232bus TD

PKIT4-5MM-101    HDO4K-USB2-HSICbus D  HDO4K-DigRFv4bus D   HDO4K-SPECTRUM  HDO4054   HDO4K-AUTO

HDO4K-FlexRaybus TD
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved