器件描述

Counters u0026 Tachometers Count Totalizer

参数

产品属性属性值
产品种类:
Product Category:
Counters & Tachometers
制造商:
Manufacturer:
Omron
RoHS:No
产品:
Product:
Counters
Display Type:LCD, 8 Digit, Backlit
工作温度范围:
Operating Temperature Range:
- 10 C to + 55 C
Voltage:3 V Lithium Battery
商标:
Brand:
Omron Automation and Safety
系列:
Series:
H7EC
工厂包装数量:
Factory Pack Quantity:
1
单位重量:
Unit Weight:
2.116438 oz

H7EC-N-B-601器件文档内容

New H7E Self-powered Totalizer

                                                                                                                                                 CSM_H7E_-N_DS_E_9_2

Compact Economical Totalizer with High Visibility
Available with Backlit LCD Display

• Large display with 8.6-mm character height.

• Includes new models with backlight for improved visibility in dimly lit places. (Requires 24-VDC power supply.)

• Black and light-gray cases now available.

• PNP/NPN universal DC voltage input types now available.

• Battery is replaceable for Totalizer reuse and conservation of the environment.

• Key-protect switch to prevent faulty reset key operation.

• Dual operation mode.

• Front face compatible with NEMA4/IP66.

• Short body, all models have a depth of 48.5 mm.

• Finger protection terminal block conforms to VDE0106, Part100.

• Conforms to UL, CSA, and CE marking.

Conforms to EN61010-1 (pollution degree 2/overvoltage category III.)

• Conforms to EMC standards and EN61326, thus allowing use in residential, commercial and light- and heavy-industry environ-

ments.

• Six-language instruction manual provided.

• PCB-mounting models available. (Requires 3-V power supply.)

■ Broad Line-up of the New H7E Series

                                                             New H7E

        New H7EC                             New H7ET                  New H7ER                                                               New H7E@-N@P

Total Counter           Time Counter                              Tachometer                                                               PCB-mounting Counter

•  8-digit              •  999999.9h/                             •   1,000 s-1 with                                                       •     Total Counter (8-digit)

                           3999d23.9h                                  1 pulse/rev. encoder                                                •     Time Counter (999999.9h)

                        •  999h59min59s/                          •   1,000.0 s-1 with

                           9999h59.9min                                10 pulse/rev. encoder

                                                                  •   1,000 min-1 with

                                                                       60 pulse/rev. encoder

                                                                  •   10,000 min-1 with

                                                                       60 pulse/rev. encoder

                                                                  •   1,000.0 min-1 with

                                                                       600 pulse/rev. encoder

            Self-powered Totalizers                          Contents

               H7EC.....................................................................................................................      2

               H7ET .....................................................................................................................     9

               H7ER.....................................................................................................................   16

               H7E@-N@P ...........................................................................................................        22

            Common to All Totalizers

               Accessories ...........................................................................................................     27

               Precautions ...........................................................................................................     29

                                                                                                                                                                           1
Self-powered Total Counter

New H7EC

• Eight-digits, counting range 0 to 99999999.

• Dual input speed: 30 Hz ←→ 1 kHz (except for AC/DC multi-

voltage input models)

                                                                                     For the most recent information on models that have been certified for

                                                                                     safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number Legend

Note: Some configurations are not available.

H7EC - N           -

               1      2    3

1. Count Input                                                                3. Display

None:       No-voltage input                                                  None:       7-segment LCD without backlight

V:          PNP/NPN universal DC voltage input                                H:          7-segment LCD with backlight

FV:         AC/DC multi-voltage input

2. Case Color

None:       Light gray

B:          Black

Note: Estimates can be provided for coatings and other  specifications  that  are not given in the datasheet. Ask your OMRON representative  for   details.

Ordering Information

■ Total Counters

     Count input              Max. counting speed                  Display                                              Model

                                                                                          Light-gray body                            Black   body

PNP/NPN universal DC          30 Hz ←→ 1    kHz         7-segment LCD with           H7EC-NV-H                          H7EC-NV-BH

voltage input                 (switchable)              backlight

(4.5 to 30 VDC)                                         7-segment LCD                H7EC-NV                            H7EC-NV-B

AC/DC multi-voltage input     20 Hz                     7-segment LCD                H7EC-NFV                           H7EC-NFV-B

(24 to 240 VAC/VDC)

No-voltage                    30 Hz ←→ 1    kHz         7-segment LCD                H7EC-N                             H7EC-N-B

                              (switchable)

■ Accessories (Order Separately)

                         Name                                                 Model

Compact Flush Mounting Bracket                          Y92F-35

Flush Mounting Bracket (See note 1)                     Y92F-34

Wire-wrap Terminal (set of two Terminals)               Y92S-37

Lithium Battery (See note 2)                            Y92S-36

Waterproof Packing (See note 1)                         Y92S-32

Note: 1.  Provided with H7EC. (Order additional Brackets separately as required.)

    2.    Built into H7EC. Order replacements using the above model number before         the  service  life  expires.

                                                                                                                                                             2
                                                                                                                            New H7EC

Specifications

■ General

                 Item                            H7EC-NV-@                             H7EC-NFV-@                           H7EC-N-@

                                                 H7EC-NV-@H

Operating mode                         Up type

Mounting method                        Flush mounting

External connections                   Screw terminals, optional Wire-wrap Terminals (see note 1)

Reset                                  External/Manual reset

Number of digits                       8

Count input                            PNP/NPN universal DC voltage in-    AC/DC multi-voltage input      No-voltage input

                                       put

Display                                7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note  2)

Max. counting speed                    30 Hz/1 kHz                         20 Hz                          30 Hz/1 kHz

Case color                             Light gray or black (-B models)

Attachment                             Waterproof packing, Y92F-34 Flush Mounting Bracket

Approved standard                      UL863, CSA C22.2 No.14, Lloyds

                                       Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)

                                       Conforms to VDE0106/P100

Note: 1.   Separately ordered Wire-wrap Terminals (Y92S-37) are required.

       2.  Only PNP/NPN universal DC voltage input models (-H models) have a backlight.

■ Ratings

           Item                   H7EC-NV-@                                H7EC-NFV-@                                 H7EC-N-@

                                  H7EC-NV-@H

Supply voltage         Backlight model: 24 VDC (0.3 W max.)   Not required (powered by built-in battery)

                       (only for backlight)

                       No-backlight model: Not required

                       (powered by built-in battery)

Count input            High (logic) level: 4.5 to 30 VDC      High (logic) level: 24 to 240 VAC/VDC,      No voltage input

                       Low (logic) level: 0 to 2 VDC          50/60 Hz                                    Maximum short-circuit impedance:

                       (Input impedance: Approx. 4.7 kΩ)      Low (logic) level: 0 to 2.4 VAC/VDC, 50/    10 kΩ max.

                                                              60 Hz                                       Short-circuit residual voltage: 0.5 V max.

Reset input                                                   No voltage input                            Minimum open impedance: 750 kΩ min.

                                                              Maximum short-circuit impedance:

                                                              10 kΩ max.

                                                              Short-circuit residual voltage: 0.5 V max.

                                                              Minimum open impedance: 750 kΩ min.

Max. counting          30 Hz or 1 KHz                         20 Hz                                       30 Hz or 1 KHz

speed (see note)       (Switchable with switch)                                                           (Switchable with switch)

Minimum signal         20 Hz:  25 ms

width                  30 Hz:  16.7 ms

                       1 KHz:  0.5 ms

Reset system           External reset and manual reset: Minimum signal width of 20 ms

Terminal screw         0.98 N·m max.

tightening torque

Ambient tempera-       Operating: –10°C to 55°C (with no condensation or icing)

ture                   Storage:   –25°C to 65°C (with no condensation or icing)

Ambient humidity       Operating  25% to 85%

Note: ON/OFF ratio     1:1

                                                                                                                                                      3
                                                                                                                              New H7EC

■ Characteristics

          Item                            H7EC-NV-@                              H7EC-NFV-@                                   H7EC-N-@
                                     H7EC-NV-@H

Insulation resistance  100 MΩ min. (at 500 VDC) between            100 MΩ min. (at 500 VDC) between             100 MΩ min. (at 500 VDC) between

                       current-carrying metal parts and ex-        current-carrying metal parts and ex-         current-carrying metal parts and ex-

                       posed non-current-carrying metal            posed non-current-carrying metal parts       posed non-current-carrying metal parts

                       parts, and between the backlight power      and between count input terminals and

                       supply terminal and count input termi-      reset terminals

                       nals/reset terminals for backlight mod-

                       els

Dielectric strength    1,000 VAC, 50/60 Hz for 1 min between       3,700 VAC, 50/60 Hz for 1 min between        1,000 VAC, 50/60 Hz for 1 min between

                       current-carrying metal parts and ex-        current-carrying metal parts and ex-         current-carrying metal parts and ex-

                       posed non-current-carrying metal parts      posed non-current-carrying metal parts       posed non-current-carrying metal parts

                       and between the backlight power sup-        2,200 VAC, 50/60 Hz for 1 min between

                       ply terminal and count input terminals/     reset terminals and exposed non-cur-

                       reset terminals for backlight models        rent-carrying metal parts and between

                                                                   count input terminals and reset termi-

                                                                   nals

Impulse withstand      4.5 kV between current-carrying termi-      4.5 kV between current-carrying termi-       4.5 kV between current-carrying termi-

voltage                nal and exposed non-current-carrying        nal and exposed non-current-carrying         nal and exposed non-current-carrying

                       metal parts                                 metal parts                                  metal parts

                                                                   3 kV between input terminals and reset

                                                                   terminals

Noise immunity         Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

                       ±600 V (Between count input terminals/ ±1.5 kV (Between count input termi-               ±500 V (Between count input terminals/

                       Between reset terminals)                    nals)                                        Between reset terminals)

                       ±480 V (Between the backlight power         ±500 V (Between reset terminals)

                       supply terminals for backlight models)

Static immunity        ±8 kV (malfunction)

Vibration resistance   Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions

                       Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions

Shock resistance       Malfunction: 200 m/s2 3 times each in 6 directions

                       Destruction: 300 m/s2 3 times each in 6 directions

EMC                    (EMI)                                   EN61326-1 (See note 1.)

                       Emission  Enclosure:                    EN55011 Group 1 class B

                       (EMS)                                   EN61326-1 (See note 1.)

                       Immunity  ESD:                          EN61000-4-2:     4 kV contact discharge (level 2)

                                                                                8 kV air discharge (level 3)

                       Immunity  RF-interference from AM Radio Waves:

                                                               EN61000-4-3:     10 V/m (80 MHz to 1 GHz) (level 3)

                       Immunity  RF-interference from Pulse-modulated Radio Waves:

                                                               EN61000-4-3:     10 V/m (900 MHz ± 5 MHz) (level 3)

                       Immunity  Conducted Disturbance:        EN61000-4-6:     10 V (0.15 to 80 MHz) (level 3)

                       Immunity  Burst:                        EN61000-4-4:     2 kV power line (level 3)

                                                                                2 kV I/O signal line (level 4)

Degree of protection   Front panel:       IP66, NEMA4

                       Terminal block: IP20

Weight (see note 2.)   No-backlight model: Approx. 60 g            Approx. 60 g                                 Approx. 60 g

                       Backlight model: Approx. 65 g

Note: 1.  Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

     2.   Weight includes waterproof packing and flush mounting bracket.

■ Reference Value

          Item                            Value                                                               Note

Battery life           7 years min. with continuous input at 25°C  The battery life is calculated according to the conditions in the left column and

                       (lithium battery)                           therefore is not a guaranteed value. Use these value as reference for mainte-

                                                                   nance or replacement.

                                                                                                                                                        4
                                                                                                                               New H7EC

Connections

■ Terminal Arrangement

Bottom view: View of the Total Counter rotated horizontally 180°

    Backlight Model                  No-backlight Model

                      Backlight

                      24 VDC

    Count      Reset                        Count  Reset

    input      input                        input  input

■ Connections

H7EC Total Counter

PNP/NPN Universal DC Voltage         Input Model With Backlight

1.  Contact Input (Input by a Relay  or Switch Contact)           2.  Solid-state Input

                                                                      Open collector of a                      Open collector of  a

    Relay                            Relay                            PNP transistor                Backlight  PNP transistor

                      Backlight                                                                     24 VDC

                      24 VDC

                                                                                           Input    Reset

               Input  Reset

    or Switch                        or Switch

                                                                      or Open collector of an                  or Open collector  of  an

                                                                      NPN transistor                           NPN transistor

                                                                      Note: 1.  Terminals 2 and 4 (input circuit and reset circuit) are     func-

                                                                                tionally isolated.

                                                                      2.        Select input transistors according to the following:

                                                                                               Dielectric strength of the collector ≥ 50 V

                                                                                               Leakage current < 100 µA

                                                                                                                                                   5
                                                                                                                                New H7EC

PNP/NPN Universal DC Voltage Input Model Without                    Backlight  No-voltage Input Model

1.  Contact Input (Input by a Relay or Switch Contact)                         1.  Contact Input (Input by a Relay or Switch Contact)

    Relay                              Relay

                                                                                   Relay                                        Relay

                                                                                                         Input     Reset

                       Input    Reset

                                                                                                         Terminals 2 and 4 are

                                                                                                         internally connected.

                                                                                          or Switch                             or Switch

    or Switch                          or Switch

2.  Solid-state Input                                                              Note: Use Relays and Switches that have high contact

                                                                                   reliability because the current flowing from terminals

    Open collector of a                Open collector of a                         1 or 3 is small. It is recommended that OMRON's

    PNP transistor                     PNP transistor                              G3TA-IA/ID be used as the SSR.

                         Input  Reset                                          2.  Solid-state Input

                                                                                   (Open Collector Input of an NPN Transistor)

                                                                                   Open collector of an                         Open collector of an

                                                                                   NPN transistor        Input     Reset        NPN transistor

    or Open collector of an            or Open collector of an                                           Terminals 2 and 4 are

    NPN transistor                     NPN transistor                                                    internally connected.  or Switch

                                                                               Note: 1. Residual voltage in the output section of Proximity

                                                                                   Sensors or Photoelectric Sensors becomes less than

                                                                                   0.5 V because the current flowing from terminals 1 or              3

                                                                                   is small thus allowing easy connection.

                                                                                   2. Select input transistors according to the following:

    Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are                          Dielectric strength of the collector ≥ 50 V

           functionally isolated.                                                             Leakage current < 1 µA

    2. Select input transistors according to the following:

                       Dielectric strength of the collector ≥ 50 V

                       Leakage current < 100 µA

AC/DC Multi-voltage Input Model

    Relay

                                Reset  Relay

                         Input

    or Switch                          or Switch

                                       or Open collector of

                                       an NPN transistor

                                                                Note: Select input transistors according to the following:

                                                                      Dielectric strength of the collector ≥ 50 V

                                                                      Leakage current < 1 µA

                                                                                                                                                         6
                                                                                                                                 New  H7EC

Operation

■ Operating Modes

H7EC Total Counter

Incrementing Operation

(Up)

           Reset

          Count input

                                                      Full-scale

                                          (Full-scale

                                          −1)

          Counting display values

Nomenclature

                                                                      Front view

                                                                  H7EC             Reset Key

                                                                                   Reset the count value. Not operable

                                                                                   under key-protect.

          Counting speed switch                                                    Key-protect Switch

          For all models except for H7EC-NFV-@.                                    The Reset Key is not operable while           the

          If the counting speed setting is changed,                                key-protect switch is set to ON.

          the present value will not be held and so

          press the Reset Key on the front panel.                                  Setting

                                                                                   (see note)          Key-protect

          Setting                  Counting speed

          (see note)                                                  Bottom view  Front panel

          Front panel                                                              Concave             OFF

                                                                                   side            (default setting)

           Concave                 30 Hz

           side                    (default setting)

                                                                                   Concave                                 ON

                                                                                   side

           Concave                 1 kHz

           side                                                                    Terminal block

          Terminal block

Note: 1.  Perform switch setting before mounting to a control panel.

2.        If the counting speed setting is changed, the present value will not be held. Press the Reset Key on the front panel.

3.        Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional.

                                                                                                                                            7
                                                                                                                                             New H7EC

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H7EC-N

                                                                M3.5 terminal  screw

                                                                                                            Panel Cutout

                                                                                                            Separate mounting

                                                                                                            40 min.

                                                                                                                      45+00.5

                                                                                                                               22.2+00.5

Dimensions with Y92F-34 Flush Mounting Bracket

                                                                                                            Dense mounting

                                                                                                                      (48 Units − 2.5)+10.0

                                                                                                                                             22.2+00.5

                                                                                                                      Waterproofing is not possible for

                                                                                                                      dense mounting

                                                                                                       •    When mounting, insert the Counter into

                                                                                                            the cutout, insert the adapter from the

                                                                                                            back and push in the Counter while

                                                                                                            making the gap between the front panel

                                                                                                            and the cutout panel as small as

                                                                                                            possible. Use screws to secure the

                                                                                                            Counter. If waterproofing is desired,

                                                                                                            insert the waterproof packing.

                                                                                                       •    When several Counters are installed,

                                                                                                            ensure that the ambient temperature

                                                                                                            will not exceed specifications.

                                                                                                       •    The appropriate thickness of the panel

                                                                                                            is 1 to 5 mm.

Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used.             Refer  to  Accessories  for  details.

                                                                                                                                                         8
Self-powered Time Counter

New H7ET

• Seven digits, time range 0 to 3999d23.9h.

• Dual time range: 999999.9 ←→ 3999d23.9h or

999h59m59s ←→ 9999h59.9m

                                                                                         For the most recent information on models that have been certified for

                                                                                         safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number Legend

Note: Some configurations are not available.

H7ET - N               -

           1      2       3   4

1. Count Input                                                                           3. Case Color

None:      No-voltage input                                                              None:       Light gray

V:         PNP/NPN universal DC voltage input                                            B:          Black

FV:        AC/DC multi-voltage input                                                     4. Display

2. Time Range                                                                            None:       7-segment LCD without backlight

None:      999999.9h/3999d23.9h                                                          H:          7-segment LCD with backlight

1:         999h59m59s/9999h59.9m

Note: Estimates can be provided for coatings and other  specifications   that  are  not  given in the datasheet. Ask your OMRON representative  for  details.

Ordering Information

■ Time Counters

          Timer input                 Display                                                           Time     range

                                                                        999999.9h ←→ 3999d23.9h                  999h59min59s ←→ 9999h59.9min

                                                                               (switchable)                                  (switchable)

                                                                 Light-gray body         Black body              Light-gray body         Black body

PNP/NPN universal DC volt-    7-segment LCD   with      back-    H7ET-NV-H               H7ET-NV-BH              H7ET-NV1-H        H7ET-NV1-BH

age input                     light

(4.5 to 30 VDC)               7-segment LCD                      H7ET-NV                 H7ET-NV-B               H7ET-NV1          H7ET-NV1-B

AC/DC multi-voltage input     7-segment LCD                      H7ET-NFV                H7ET-NFV-B              H7ET-NFV1         H7ET-NFV1-B

(24 to 240 VAC/VDC)

No-voltage input              7-segment LCD                      H7ET-N                  H7ET-N-B                H7ET-N1           H7ET-N1-B

■ Accessories (Order Separately)

                       Name                                                Model

Compact Flush Mounting Bracket                          Y92F-35

Flush Mounting Bracket (See note 1)                     Y92F-34

Wire-wrap Terminal (set of two terminals)               Y92S-37

Lithium Battery (See note 2)                            Y92S-36

Waterproof Packing (See note 1)                         Y92S-32

Note: 1.   Provided with H7ET. (Order additional Brackets separately as required.)

    2.     Built into H7ET. Order replacements using the above model number before       the  service   life  expires.

                                                                                                                                                                 9
                                                                                                                                       New H7ET

Specifications

■ General

           Item              H7ET-NV-@            H7ET-NFV-@                   H7ET-N-@   H7ET-NV1-@                H7ET-NFV1-@        H7ET-N1-@

                          H7ET-NV-@H                                                      H7ET-NV1-@H

Operating mode         Accumulating

Mounting method        Flush mounting

External connections   Screw terminals

Reset                  External/Manual reset

Display                7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1)

Number of digits       7

Time range             0.0h to 999999.9h ←→ 0.0h to 3999d23.9h                            0s to 999h59min59s ←→ 0.0min to 9999h59.9min

                       (switchable with switch)                                           (switchable with switch)

Timer input            PNP/NPN univer-        AC/DC multi-volt-         No-voltage input  PNP/NPN univer-           AC/DC multi-volt-  No-voltage input

                       sal DC voltage in-     age input                 (see note 2)      sal DC voltage in-        age input

                       put                                                                put

Case color             Light gray or black (-B models)

Attachment             Waterproof packing, Y92F-34 Flush Mounting Bracket, time unit labels (see note 3)

Approved standard      UL863, CSA C22.2 No.14, Lloyds

                       Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III)

                       Conforms to VDE0106/P100

Note: 1.   Only PNP/NPN universal DC voltage input models (-H models) have a backlight.

       2.  The frequency range for an AC voltage is 50 to 60 Hz.

       3.  “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.

       4.  Zero suppression: Zeros are not displayed to increase readability. For example, "000008.2" is displayed as "8.2" if zero suppression                 is

                          set. If the range is set to 3999d23.9h, the value is "008.2".

■ Ratings

           Item                     H7ET-NV@-@                                      H7ET-NFV@-@                                 H7ET-N@-@

                             H7ET-NV@-@H

Supply voltage     Backlight model: 24 VDC (0.3 W max.)                 Not required (powered by built-in battery)

                   (for backlight)

                   No-backlight model: Not required (pow-

                   ered by built-in battery)

Timer input        High (logic) level: 4.5 to 30 VDC                    High (logic) level: 24 to 240 VAC/VDC,      No voltage input

                   Low (logic) level: 0 to 2 VDC                        50/60 Hz                                    Maximum short-circuit impedance:

                   (Input impedance: Approx. 4.7 kΩ)                    Low (logic) level: 0 to 2.4 VAC/VDC, 50/    10 kΩ max.

                                                                        60 Hz                                       Short-circuit residual voltage: 0.5 V max.

Reset input                                                             No voltage input                            Minimum open impedance: 750 kΩ min.

                                                                        Maximum short-circuit impedance:

                                                                        10 kΩ max.

                                                                        Short-circuit residual voltage: 0.5 V max.

                                                                        Minimum open impedance: 750 kΩ min.

Minimum pulse      1s

width

Reset system       External reset and manual reset: Minimum signal width of 20 ms

Terminal screw     0.98 N·m max.

tightening torque

Ambient tempera-   Operating: –10°C to 55°C (with no condensation or icing)

ture               Storage:  –25°C to 65°C (with no condensation or icing)

Ambient humidity   Operating: 25% to 85%

                                                                                                                                                                    10
                                                                                                                            New H7ET

■ Characteristics

          Item                       H7ET-NV@-@                               H7ET-NFV@-@                                   H7ET-N@-@
                                    H7ET-NV@-H@

Time accuracy          ±100 ppm (25°C)

Insulation resistance  100 MΩ min. (at 500 VDC) between         100 MΩ min. (at 500 VDC) between              100 MΩ min. (at 500 VDC) between

                       current-carrying metal parts and ex-     current-carrying metal parts and ex-          current-carrying metal parts and ex-

                       posed non-current-carrying metal         posed non-current-carrying metal              posed non-current-carrying metal

                       parts, and between the backlight pow-    parts and between timer input termi-          parts

                       er supply and timer input terminals/re-  nals and reset terminals

                       set terminals for backlight models

Dielectric strength    1,000 VAC, 50/60 Hz for 1 min between    3,700 VAC, 50/60 Hz for 1 min between         1,000 VAC, 50/60 Hz for 1 min between

                       current-carrying metal parts and ex-     timer input terminals and exposed non-        current-carrying metal parts and ex-

                       posed non-current-carrying metal         current-carrying metal parts                  posed non-current-carrying metal

                       parts and between the backlight power    2,200 VAC, 50/60 Hz for 1 min between         parts

                       supply and timer input terminals/reset   reset terminals and exposed non-cur-

                       terminals for backlight models           rent-carrying metal parts and between

                                                                timer input terminals and reset termi-

                                                                nals

Impulse withstand      4.5 kV between current-carrying termi-   4.5 kV between current-carrying termi-        4.5 kV between current-carrying termi-

voltage                nal and exposed non-current-carrying     nal and exposed non-current-carrying          nal and exposed non-current-carrying

                       metal parts                              metal parts                                   metal parts

                                                                3 kV between timer input terminals and

                                                                reset terminals

Noise immunity         Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

                       ±600 V (Between timer input terminals/   ±1.5 kV (Between timer input termi-           ±500 V (Between timer input terminals/

                       Between reset terminals)                 nals)                                         Between reset terminals)

                       ±480 V (Between the backlight power      ±500 V (Between reset terminals)

                       supply terminals for backlight models)

Static immunity        ±8 kV (malfunction)

Vibration resistance   Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions

                       Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions

Shock resistance       Malfunction: 200 m/s2 3 times each in 6 directions

                       Destruction: 300 m/s2 3 times each in 6 directions

EMC                    (EMI)                                    EN61326-1 (See note 1.)

                       Emission Enclosure:                     EN55011 Group 1 class B

                       (EMS)                                    EN61326-1 (See note 1.)

                       Immunity ESD:                           EN61000-4-2:   4 kV contact discharge (level 2)

                                                                              8 kV air discharge (level 3)

                       Immunity RF-interference from AM Radio Waves:

                                                                EN61000-4-3:  10 V/m (80 MHz to 1 GHz) (level 3)

                       Immunity RF-interference from Pulse-modulated Radio Waves:

                                                                EN61000-4-3:  10 V/m (900 MHz ± 5 MHz) (level 3)

                       Immunity Conducted Disturbance:          EN61000-4-6:  10 V (0.15 to 80 MHz) (level 3)

                       Immunity Burst:                          EN61000-4-4:  2 kV power line (level 3)

                                                                              2 kV I/O signal line (level 4)

Degree of protection   Front panel:            IP66, NEMA4 with waterproof packing

                       Terminal block: IP20

Weight (see note 2.)   No-backlight model: Approx. 60 g         Approx. 60 g                                  Approx. 60 g

                       Backlight model: Approx. 65 g

Note: 1.  Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

     2.   Weight includes waterproof packing and flush mounting bracket.

■ Reference Value

          Item                       Value                                                               Note

Battery life           10 years min. with continuous input at   The battery life is calculated according to the conditions in the left column and

                       25°C (lithium battery)                   therefore is not a guaranteed value. Use these value as reference for mainte-

                                                                nance or replacement.

                                                                                                                                                      11
                                                                                                                              New H7ET

Connections

■ Terminal Arrangement

Bottom view: View of the Time Counter rotated horizontally 180°

    Backlight Model              No-backlight Model

                      Backlight

                      24 VDC

                                 Timer                  Reset

    Timer      Reset             input                  input

    input      input

■ Connections

H7ET Time Counter

PNP/NPN Universal DC Voltage Input Model With Backlight

1.  Contact Input (Input by a Relay or Switch Contact)           2.  Solid-state Input

                                                                     Open collector of a                      Open collector of  a

    Relay                        Relay                               PNP transistor                Backlight  PNP transistor

                      Backlight                                                                    24 VDC

                      24 VDC

                                                                                        Input      Reset

               Input  Reset

    or Switch                    or Switch

                                                                     or Open collector of an                  or Open collector  of  an

                                                                     NPN transistor                           NPN transistor

                                                                     Note: 1.  Terminals 2 and 4 (input circuit and reset circuit) are   func-

                                                                               tionally isolated.

                                                                     2.        Select input transistors according to the following:

                                                                                          Dielectric strength of the collector ≥ 50 V

                                                                                          Leakage current < 1 µA

                                                                                                                                                12
                                                                                                                                  New H7ET

PNP/NPN Universal DC Voltage Input Model Without                      Backlight  No-voltage Input Model

1.  Contact Input (Input by a Relay or Switch Contact)                           1.  Contact Input (Input by a Relay or           Switch Contact)

    Relay                                   Relay

                                                                                     Relay                 Input  Reset           Relay

                         Input  Reset

                                                                                                           Terminals 2 and 4 are

                                                                                                           internally connected.

                                                                                     or Switch                                    or Switch

    or Switch                               or Switch

                                                                                 Note: Use Relays and Switches that have high contact

2.  Solid-state Input                                                                reliability because the current flowing from terminals 1

    Open collector of a                Open collector of a                           or 3 is as small as approx. 10 µA. It is recommended

    PNP transistor                     PNP transistor                                that OMRON's G3TA-IA/ID be used as the SSR.

                         Input  Reset                                            2.  Solid-state Input

                                                                                     (Open Collector Input of an NPN Transistor)

                                                                                     Open collector of an                         Open collector of an

                                                                                     NPN transistor        Input  Reset           NPN transistor

    or Open collector of an            or Open collector of an                                             Terminals 2 and 4 are

    NPN transistor                     NPN transistor                                                      internally connected.  or Switch

                                                                                 Note: 1. Residual voltage in the output section of Proximity

                                                                                     Sensors or Photoelectric Sensors becomes less

                                                                                     than 0.5 V because the current flowing from

                                                                                     terminals 1 or 3 is as small as approx. 10 µA, thus

                                                                                     allowing easy connection.

    Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are                 2. Select input transistors according to the following:

    functionally isolated.                                                                           Dielectric strength of the collector ≥ 50 V

    2. Select input transistors according to the following:                                          Leakage current < 1 µA

                    Dielectric strength of the collector ≥ 50 V

                    Leakage current < 1 µA

AC/DC Multi-voltage Input Model

    Relay

                                Reset       Relay

                         Input

    or Switch                          or Switch

                                       or Open collector of

                                       an NPN transistor

                                                                                                                                                        13
                                                                                                                            New H7ET

Operation

■ Operating Modes

H7ET Time Counter

Incrementing Operation

(Up)            Reset

                Timer input

                Internal clock

                timer value

                                                       Full-scale
                                         (Full-scale

                                         −0.1 (1))

      Timer display values

Nomenclature

                                                                          Front view

                                         Location to Attach

                                         Unit Label

                                         Attach the correct unit

                                         label for the time range                             Reset Key

                                         that is set.                  H7ET

                                                                                              Reset the count value. Not operable

                                                                                              under key-protect.

                                         Time-range switch                                    Key-protect Switch

                                         If the time-range setting is                         The Reset Key is not operable while         the

                                         changed, the present                                 key-protect switch is set to ON.

                                         value will not be held and                                  Setting

                                         so press the Reset Key on                                   (see note)        Key-protect

                                         the front panel.

                                                                                                     Front panel

Setting                            Time  range                            Bottom view                   Concave             OFF

(see note)                                                                                              side           (default setting)

                H7ET-N@@-@@              H7ET-N@@1-@@

Front panel

      Concave   0.0h to 3999d23.9h       0s to 999h59min59s

      side                               (default setting)

                                                                                                        Concave             ON

                                                                                                        side

                                                                                                     Terminal block

      Concave   0.0h to 999999.9h        0.0min to 9999h59.9min

      side      (default setting)

Terminal block

Display Values for a Time Range of ”0.0h to 3999d23.9h”

If the time-range switch is set to ”0.0h to 3999d23.9h,” the four leftmost digits are the number of     days      and  the  three  rightmost

digits are the number of hours.

The initial value after resetting is 000.00 (0 days, 00.0 hours).

After ”023.9” (0 days, 23.9 hours), the display will change to ”100.0” (1 days, 00.0 hours).

LCD Examples for ”0.0h to 3999d23.9h” Range

                d               h                                      d     h                                                     d           h

                                         After 24                                             After 24

                                         hours, 54                                            hours

                                         minutes

Note: Perform switch setting before mounting to a control panel.

                                                                                                                                                  14
                                                                                                                                         New H7ET

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H7ET-N

                                                                                                        Panel Cutout

                                                                                                        Separate mounting

                                                                                                        40 min.

                                                                                                                  45+00.5

Dimensions with Y92F-34 Flush Mounting Bracket                                                                             22.2+00.5

                                                                                                        Dense mounting

                                                                                                                  (48 Units − 2.5)+10.0

                                                                                                                                         22.2+00.5

                                                                                                        Waterproofing is not possible

                                                                                                        for dense mounting

                                                                                                   •    When mounting, insert the Counter into

                                                                                                        the cutout, insert the adapter from the

                                                                                                        back and push in the Counter while

                                                                                                        making the gap between the front panel

                                                                                                        and the cutout panel as small as

                                                                                                        possible. Use screws to secure the

                                                                                                        Counter. If waterproofing is desired,

                                                                                                        insert the waterproof packing.

                                                                                                   •    When several Counters are installed,

                                                                                                        ensure that the ambient temperature

                                                                                                        will not exceed specifications.

                                                                                                   •    The appropriate thickness of the panel

                                                                                                        is 1 to 5 mm.

Note: A Compact Flush Mounting Bracket (Y92F-35) can also       be  used.  Refer  to  Accessories  for  details.

                                                                                                                                                    15
Self-powered Tachometer

New H7ER

• Revolutions displayed up to five digits.

• Dual revolution display according to encoder resolution used;

1000 s–1/1000 min–1 or 1000.0 s–1 /1000.0 min–1

• Switchable dual revolution display type available (-NV1 models);

extended up to 10000 min–1

                                                                                    For the most recent information on models that have been certified for

                                                                                    safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number Legend

Note: Some configurations are not available.

H7ER - N             -

          1       2     3     4

1. Count Input                                                          3. Case Color

None:     No-voltage input                                              None:       Light gray

V:        PNP/NPN universal DC voltage input                            B:          Black

2. Number of Digits                                                     4. Display

None:     4 digits                                                      None:       7-segment LCD without backlight

1:        5 digits                                                      H:          7-segment LCD with backlight

Note: Estimates can be provided for coatings and other  specifications  that are not given in the datasheet. Ask your OMRON  representative  for  details.

Ordering Information

■ Tachometers

Count input                Display                               Max. revolutions displayed (applicable encoder resolution)

                                            1000 s–1 (1 pulse/rev.),                            1000.0 s–1 (10 pulse/rev.),

                                            1000 min–1 (60 pulse/rev.)                          1000.0 min–1 (600 pulse/rev.) ←→

                                                                                                10000 min–1 (60 pulse/rev.) (switchable)

                                              Light-gray body           Black body                   Light-gray body                Black body

PNP/NPN universal    7-segment LCD          H7ER-NV-H                   H7ER-NV-BH              H7ER-NV1-H                   H7ER-NV1-BH

DC voltage input     with backlight

(4.5 to 30 VDC)      7-segment LCD          H7ER-NV                     H7ER-NV-B               H7ER-NV1                     H7ER-NV1-B

No-voltage input     7-segment LCD          H7ER-N                      H7ER-N-B                ---                          ---

■ Accessories (Order Separately)

                     Name                                               Model

Compact Flush Mounting Bracket                          Y92F-35

Flush Mounting Bracket (See note 1)                     Y92F-34

Wire-wrap Terminal (set of two terminals)               Y92S-37

Lithium Battery (See note 2)                            Y92S-36

Waterproof Packing (See note 1)                         Y92S-32

Note: 1.  Provided with H7ER. (Order additional Brackets separately as required.)

    2.    Built into H7ER. Order replacements using the above model number before      the  service  life  expires.

                                                                                                                                                            16
                                                                                                                    New H7ER

Specifications

■ General

                 Item                           H7ER-NV-@                    H7ER-N-@                       H7ER-NV1-@

                                           H7ER-NV-@H                                                       H7ER-NV1-@H

Operating mode                      Up type

Mounting method                     Flush mounting

External connections                Screw terminals, Wire-wrap Terminals (see note 3)

Display                             7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 4)

Number of digits                    4                                                     5

Count input                         PNP/NPN universal DC            No-voltage input      PNP/NPN universal DC voltage input

                                    voltage input

Max. counting speed                 1 kHz                                                 10 kHz

Max. revolutions displayed          1,000 s–1 (When encoder resolution of 1 pulse/rev is  1,000.0 s–1 (When encoder resolution of 10 pulse/rev

(see note 5, 6)                     used.)                                                is used.)

                                    1,000 min–1 (When encoder resolution of 60 pulse/     1,000.0 min–1 (When encoder resolution of

                                    rev is used.)                                         600 pulse/rev is used.)

                                                                                          ←→ 10,000 min–1 (When encoder resolution of

                                                                                          60 pulse/rev is used.)

                                                                                          (Switchable with switch)

Attachment                          Waterproof packing, Y92F-34 Flush Mounting Bracket, revolution unit labels (see note 5)

Approved standard                   UL863, CSA C22.2 No.14, Lloyds

                                    Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)

                                    Conforms to VDE0106/P100

Note: 1.  Reset is not available.

2.        When there is no input, the display will be 0.0 or 0.

3.        Separately ordered Wire-wrap Terminals (Y92S-37) are required.

4.        Only PNP/NPN Universal DC voltage input models have a backlight.

5.        “rpm”, “rps”, “s–1” and “min–1” labels are included.

6.        "s-1" in "1,000 s-1" means the same thing as RPS. "min-1" means the same thing as RPM.

■ Ratings

                 Item                                           H7ER-NV@-@                                        H7ER-N-@

                                                                H7ER-NV@-@H

Supply voltage                      Backlight model: 24 VDC (0.3 W max.) (for backlight   Not required (powered by built-in battery)

                                    lit)

                                    No-backlight model: Not required (powered by built-

                                    in battery)

Count input                         High (logic) level: 4.5 to 30 VDC                     No voltage input

                                    Low (logic) level: 0 to 2 VDC                         Maximum short-circuit impedance: 10 kΩ       max.

                                    (Input impedance: Approx. 4.7 kΩ)                     Short-circuit residual voltage: 0.5 V max.

                                                                                          Minimum open impedance: 750 kΩ min.

Max. counting speed                 4-digit models:1 kHz                                  1 kHz

                                    5-digit models:10 kHz

Minimum signal width                10 kHz: 0.05 ms

                                    1 kHz:      0.5 ms (See note.)

Terminal screw tightening   torque  0.98 N·m max.

Ambient temperature                 Operating: –10°C to 55°C (with no condensation or icing)

                                    Storage:     –25°C to 65°C (with no condensation or icing)

Ambient humidity                    Operating: 25% to 85%

Note: 5-digit models :1 kHz/10 kHz switchable.

                                                                                                                                                17
                                                                                                                                 New H7ER

■ Characteristics

                Item                                           H7ER-NV@-@                                     H7ER-N-@
                                                            H7ER-NV@-@H

Insulation resistance                     100 MΩ min. (at 500 VDC) between current-carrying      100 MΩ min. (at 500 VDC) between current-carrying

                                          metal parts and exposed non-current-carrying metal     metal parts and exposed non-current-carrying metal

                                          parts, and between the backlight power supply and      parts

                                          count input terminals/reset terminals for backlight

                                          models

Dielectric strength                       1,000 VAC, 50/60 Hz for 1 min between current-car-     1,000 VAC, 50/60 Hz for 1 min between current-car-

                                          rying metal parts and exposed non-current-carrying     rying metal parts and exposed non-current-carrying

                                          metal parts and between the backlight power supply     metal parts

                                          and count input terminals/reset terminals for back-

                                          light models

Impulse withstand voltage                 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts

Noise immunity                            Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

                                          ±600 V (Between count input terminals)                 ±500 V (Between count input terminals)

                                          ±480 V (Between the backlight power supply termi-

                                          nals for backlight models)

Static immunity                           ±8 kV (malfunction)

Vibration resistance                      Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions

                                          Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions

Shock resistance                          Malfunction: 200 m/s2 3 times each in 6 directions

                                          Destruction: 300 m/s2 3 times each in 6 directions

EMC                                       (EMI)                               EN61326-1 (See note 1.)

                                          Emission  Enclosure:                EN55011 Group 1 class B

                                          (EMS)                               EN61326-1 (See note 1.)

                                          Immunity  ESD:                      EN61000-4-2:     4 kV contact discharge (level 2)

                                                                                               8 kV air discharge (level 3)

                                          Immunity  RF-interference from AM Radio Waves:

                                                                              EN61000-4-3:     10 V/m (80 MHz to 1 GHz) (level 3)

                                          Immunity  RF-interference from Pulse-modulated Radio Waves:

                                                                              EN61000-4-3:     10 V/m (900 MHz ± 5 MHz) (level 3)

                                          Immunity  Conducted Disturbance:    EN61000-4-6:     10 V (0.15 to 80 MHz) (level 3)

                                          Immunity  Burst:                    EN61000-4-4:     2 kV power line (level 3)

                                                                                               2 kV I/O signal line (level 4)

Degree of protection                      Front panel:      IP66, NEMA4 with waterproof packing

                                          Terminal block: IP20

Weight (see note 2.)                      No-backlight model:Approx. 60 g

                                          Backlight model:      Approx. 65 g

Note: 1.  Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

     2.   Weight includes waterproof packing and flush mounting bracket.

■ Reference Value

          Item                            Value                                                         Note

Battery life          7 years min. with continuous input at 25°C      The battery life is calculated according to the conditions in the left column and

                       (lithium battery)                              therefore is not a guaranteed value. Use these value as reference for mainte-

                                                                      nance or replacement.

                                                                                                                                                         18
                                                                                                               New H7ER

Connections

■ Terminal Arrangement

Bottom view: View of the Tachometer rotated horizontally 180°

Backlight Model                                  No-backlight Model

                       Backlight

                       24 VDC

                                                 Pulse

Pulse                                            input

input

■ Connections

H7ER Tachometer

Note: Select input transistors according to the following:

Dielectric strength of the collector ≥ 50 V

Leakage current < 100 µA (1 µA for no-voltage input model)

PNP/NPN Universal DC Voltage Input Models With Backlight             No-voltage Input Model

Transistor Input                                                     Transistor Input (Open Collector  of  an  NPN Transistor)

Open collector of  or  Open collector of                             Open collector of

an NPN transistor      an PNP transistor                             an NPN transistor  Input

                                                 Backlight

                                                 24 VDC

                                          Input

PNP/NPN Universal DC Voltage Input Models Without Backlight

Transistor Input

Open collector of  or  Open collector of

an NPN transistor      an PNP transistor

                                          Input

                                                                                                                                19
                                                                                                                                                 New H7ER

Operation

■  Operating Modes

   H7ER Tachometer

   Incrementing Operation

   Within Unit Time (Up)

                               Count  period   0.25  sCoun(1t  period

                               (1     s)                       s)

                Internal gate

                                                  Display refreshed          Refresh

                                                     Counter reset

       Internal count value

       Number display          Previous count

                               value display

                               Display refreshed     Display refreshed

                               every 1.25 s          every 1.25 s

Nomenclature

                                                                                                         Front view

                                                                                                                               Applicable

                                                                                                                               unit label

                                                                                                         H7ER

                                                     Counting speed switch                                                     Not used

                                                     For H7ER-NV1-@@

                                                                                                         Bottom view

                               Counting Speed Switch                                  Settings and Unit Label Application

                                                     Counting speed                   Max. revolutions   Applicable encoder    Applicable unit

                                      Model          switch setting                   displayed                resolution      label

                                                               (see note)

                                                     Front panel

                               H7ER-NV1-@@                             Concave        10000 min-1                              "min-1" or "rpm"

                                                                       side           (default setting)        60 pulse/rev.

                                                                                      1000.0 min-1             600 pulse/rev.  "min-1" or "rpm"

                                                                       Concave

                                                                       side

                                                     Terminal block                   1000.0 s-1               10 pulse/rev.   "s-1" or "rps"

                                                                                      1000 min-1               60 pulse/rev.   "min-1" or "rpm"

                               H7ER-N-@              No setting is

                               H7ER-NV-@@            required

                                                                                      1000 s-1                 1 pulse/rev.    "s-1" or "rps"

Note:  Perform  switch  setting before mounting to a control panel.

                                                                                                                                                           20
                                                                                                                                        New H7ER

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H7ER-N

                                                                                                      Panel Cutout

                                                                                                      Separate mounting

                                                                                                      40 min.

                                                                                                                 45+00.5

                                                                                                                          22.2+00.5

Dimensions with Y92F-34 Flush Mounting Bracket                                                        Dense mounting

                                                                                                                 (48 Units − 2.5)+10.0

                                                                                                                                        22.2+00.5

                                                                                                      Waterproofing is not possible

                                                                                                      for dense mounting

                                                                                                   •  When mounting, insert the Counter into

                                                                                                      the cutout, insert the adapter from the

                                                                                                      back and push in the Counter while

                                                                                                      making the gap between the front panel

                                                                                                      and the cutout panel as small as

                                                                                                      possible. Use screws to secure the

                                                                                                      Counter. If waterproofing is desired,

                                                                                                      insert the waterproof packing.

                                                                                                   •  When several Counters are installed,

                                                                                                      ensure that the ambient temperature

                                                                                                      will not exceed specifications.

                                                                                                   •  The appropriate thickness of the panel

                                                                                                      is 1 to 5 mm.

Note: A Compact Flush Mounting Bracket (Y92F-35) can also       be  used.  Refer  to  Accessories  for details.

                                                                                                                                                   21
PCB-mounting Counters

H7E@-N@P

• Dedicated for use on PCB.

• Total Counters and Time Counter available.

                                                               For the most recent information on models that have been certified for

                                                               safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number Legend

H7E     -N        P

     1       2

1. Function

C:      Total Counter

T:      Time Counter

2. Max. Counting Speed for H7EC Models

None:   1 kHz

L:      30 Hz

Ordering Information

■ PC Board-use Counters

        Count input          Display                           Total counter                                   Time counter

                                                               Max. counting speed

                                                       1  kHz                       30 Hz

No-voltage input            7-segment LCD     H7EC-NP          H7EC-NLP                    H7ET-NP

■ Accessory (Order Separately)

Connecting Socket (28-pin)   XR2A-2801-N

                                                                                                                                       22
                                                                                                                      H7E@-N@P

Specifications

■ General

               Item                                     Total Counter                                                Time Counter

                                             H7EC-NP                               H7EC-NLP                           H7ET-NP

Operating mode                  Up type

Mounting method                 Direct mounting on PC Board or mounting on         28-pin socket

Reset                           External reset, Power-OFF reset

Number of digits                8                                                                           7

Time range                      ---                                                                         0.0h to 999999.9h

Max. counting speed             1 kHz                                       30 Hz                           ---

Count/Timer input               No-voltage input

Display                         7-segment LCD (character height: 8.6 mm)

Case color                      Transparent

Approved standard               UL863, CSA C22.2 No.14

■ Ratings

                Item                                  H7EC-NP                                                    H7ET-NP
                                                     H7EC-NLP

Supply voltage                  3 VDC (2.7 to 3.3 VDC)

Count/Timer input               No voltage input

Reset input                     Maximum short-circuit impedance: 10 kΩ max.

                                Short-circuit residual voltage: 0.5 V max.

                                Minimum open impedance: 750 kΩ min.

Max. counting speed (see note)  1 kHz: Minimum signal width of 0.5 ms              ---

                                30 Hz: Minimum signal width of 16.7 ms

Minimum signal input width      ---                                                1s

Reset system                    External reset: Minimum signal width of 20 ms

                                Power-OFF reset: Minimum power OFF time of 500 ms

Ambient temperature             Operating: –10°C to 55°C (with no condensation or icing)

                                Storage:     –25°C to 65°C (with no condensation or icing)

Ambient humidity                Operating: 25% to 85%

Note: ON/OFF ratio 1:1

■ Characteristics

                Item                                  H7EC-NP                                                    H7ET-NP
                                                     H7EC-NLP

Time accuracy                   ---                                                ±100 ppm (25°C)

Noise immunity                  Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

                                ±500 V (Between count or timer input terminals/Between reset terminals)

Static immunity                 ±8 kV (malfunction)

Vibration resistance            Malfunction:0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions

                                Destruction:0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions

Shock resistance                Malfunction:200 m/s2 3 times each in 6 directions

                                Destruction:300 m/s2 3 times each in 6 directions

EMC                             (EMI)                                              EN61326-1 (See note 1.)

                                Emission Enclosure:                                EN55011 Group 1 class B

                                (EMS)                                              EN61326-1 (See note 1.)

                                Immunity ESD:                                      EN61000-4-2: 4-kV contact discharge (level 2)

                                                                                                  8-kV air discharge (level 3)

                                Immunity RF-interference from AM Radio Waves:

                                                                                   EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)

                                Immunity RF-interference from Pulse-modulated Radio Waves:

                                                                                   EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)

                                Immunity Conducted Disturbance (see note):EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)

                                Immunity Burst (see note 2.):                      EN61000-4-4: 2-kV I/O signal line (level 4)

Weight                          Approx. 20 g

Note: 1.   Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

       2.  The power supply terminals of the H7E@-N@P are considered as 3-VDC control terminals.

                                                                                                                                    23
                                                                                                                                                    H7E@-N@P

Connections

■ Terminal Arrangement

H7EC-N@P                                   3-VDC external                            H7ET-NP                           3-VDC external

                                           power supply                                                                power supply

          Reset        Bottom view         Count                                         Reset       Bottom view           Timer

          input                            input                                         input                             input

                                                                                                     

                          Top    view                                                                   Top     view

                 omronH7EC       COUNTS                                                              omronH7ET  COUNTS

                                                                                                         

■ Connections

Power Supply and Battery                                    Connections

Battery Connections                                                                      Backup Circuit for Protection Against Power Failure

                                       3-V battery

                                                                                                                H7E@-N@P

                                       H7E@-N@P

                                                                                                                                     3-V

                                                                                                                                     bat-  Backup

                                                                                                                                     tery  circuit

When designing a circuit, keep the power wiring connections shorter than 50

mm. Refer to the connection diagram above for the proper wiring polarity.                Use a diode (D) having a forward voltage as small as possible (0.1 V

The life expectancy of a battery power supply can be calculated by                       max. at IF of 20 μA).

the following formula:                                                                   Determine the ratio of R1 to R2 in accordance with the forward volt-

t = A/lc                                                                                 age of the diode to be used. Be aware that when the power supplied

Where,                                                                                   to     the  H7E@-N@P         has  dropped     to  less     than  the  voltage  of  the

t:   Life expectancy of battery (h)                                                      backup circuit, the battery will discharge.

A:   Battery capacity (mAh)                                                              To protect the circuit against a momentary power failure, an aluminum

lc:  H7E@-N@P current consumption (mA)                                                   electrolyte capacitor can be used in place of a battery, as shown below:

Example:

Battery   life   when     using  a  3-V    lithium       battery  with  a  capacity  of

1,200 mAh for the H7E@-N@P.                                                                                     H7E@-N@P

t = 1,200 [mAh]/20 × 10–3 [mA] = 60,000 hours (approx. 6.8 years)

The battery capacity varies depending on the type of battery used;

oxidized silver, mercury, or lithium battery.

                                                                                                                                           Backup

Voltage Division of Power Supply Circuit                                                                                                   circuit

When necessary, the voltage from the battery may be divided by resistances:              When a capacitor is used, its backup time can be calculated by the

                                                                                         following formula:

                                                                                         t = C (V1 – V2) / Ic

                       H7E@-N@P                                                          Where,

                                                                                         t:     Backup time (s)

                                                                                         C:     Capacitance (μF)

                                                                                         V1: Supply voltage before power failure (V)

                                                                                         V2: Minimum operating voltage of H7E@-N@P (V)

                                                                                         Ic:    H7E@-N@P current consumption (μA)

When doing so, however, ensure that the following equation balances:                     Example:

E (V) × R2 / (R1 + R2) = 3 V                                                             Backup time by an aluminum electrolytic capacitor of 100 μF. (Mini-

                                                                                         mum operating voltage of H7E@-N@P is 2.6 V.)

          R                                              E                               t = 100 μF × (3–2.6 V)/20 μA = 100 × 0.40/20 = 2.0 seconds

                               5V                   12 V                   24 V          Note   that    the     above   calculation    provides     an    approximate   value,

R1                     2 kΩ                9.1 kΩ                 33 kΩ                  which varies depending on the environment under which the Counter

R2                     3 kΩ                3 kΩ                   4.7 kΩ                 is used and also on the type of capacitors used. Provide some allow-

                                                                                         ance in selecting capacitors.

Allow a current high enough to flow through R1 so that the H7E@-                         Keep the wiring between the H7E@-N@P and R2 or C as short as

N@P receives sufficient current.                                                         possible (within 50 mm).

C is a film capacitor, of about 0.1 μF, and is intended to absorb noise

induced by the power lines.

Keep the wiring between the H7E@-N@P and R2 or C as short as

possible (within 50 mm).

                                                                                                                                                                                 24
                                                                                                                                   H7E@-N@P

Input Connections                                                                Solid State Input

Input Connection Contact Input                                                   Open-collector Transistor Input

                                                                                                  H7E@-N@P

      Relay                    H7E@-N@P              Relay

                                                                                 Reset input                Count/Timer input

             Reset input                 Count/Timer input                       TTL or C-MOS IC Input

             Or                             Or

                                                                                 TTL or C-MOS IC            H7E@-N@P               TTL or C-MOS IC

When the H7EC-NP is used, relay chattering may be           counted.  Use

the H7EC-NLP, one of the low-speed input models.

                                                                                                       Reset input    Count/Timer input

                                                                                 Use a transistor for input that satisfies the following conditions:

                                                                                 Collector breakdown voltage ≥ 50 V

                                                                                 Leakage current < 1 µA

                                                                                 Use a diode (D) having a forward voltage as small as possible (0.1 V

                                                                                 max. at IF of 20 µA).

Operation

■ Operating Modes

H7EC Total Counter                                                         H7ET Time Counter

Incrementing Operation                                                     Incrementing Operation

(Up)                                                                       (Up)

             Reset                                                               Reset

      Count input                                                                Timer input

                                         Full-scale

                               (Full-scale                                       Internal clock

                               −1)                                               timer value

                                                                                                                               Full-scale

                                                                                                                      (Full-scale

      Counting display values                                                                                         −0.1

                                                                                 Timer display values

                                                                                                                                                       25
                                                                                        H7E@-N@P

Dimensions

Note: All units are in millimeters unless  otherwise  indicated.

H7EC-N@P                                                                  DIP Terminal  PCB Processing Dimensions

                                                                                        (Soldering Surface)

                                                                                        Section occupied

                                                      DIP terminal  x  8                by the Counter       Eight, 0.8 dia.

                                                                          Base

          17.3 max.

H7ET-NP

                                           43                                           Note: Processing dimensions are

                                                                                        for 28-pin IC socket.

                                                                                                                              26
                                                                                                                                                 H7E@-N@P

Accessories (Order Separately) (Common)

■ New H7E (Except for PCB-mounting Counter)

The New H7E models are supplied with a mounting bracket (Y92F-34) and nut. Additionally, the Y92F-75/-76/-77B Flush Mounting Adapters shown

here allow the New H7E models to be fitted to existing panel cutouts.

Y92F-35 Compact Flush Mounting Bracket                                                                                          Panel Cutout

                                                                                                                    Single  mounting             Dense mounting

                                                                   47.6        2.4     18.6        4                                                 (48 × No. of units

                                                                                                                                                     − 2.5)+10.0

                                                     26                                                                                                                  22.2+00.5

                                                                                                      30 min.

                         RST                                                                                                          22.2+00.5

                                                                                                                       45+00.5

Degree of protection (front): IP40 (not waterproof)                                 •  The minimum mounting interval is 30 mm.

The DIP switch of the H7E@-N can be operated in mounted condi-                         Note: An interval of 40 mm is recommended for easier wiring.

tion. Vibration resistance and shock resistant are the same level as                •  Do not allow the ambient temperature of the H7E@-N to exceed                      the

the H7E@-N series.                                                                     specifications (55°C).

                                                                                    •  Mounting is possible onto panels with a thickness of 1 to 5 mm.

Y92F-75 Flush Mounting Adapter

for 26 × 45.3 Rectangular Cutout

Use mounting bracket supplied with the Counter                                         Two 3.5 dia. mounting holes                        Panel Cutout

                                                                                                                                                        Two, M3

                                                             31    24.2 22.2                                                26

                                                                                                                                26

                                                                                             45.2                   4                            45.3

(Color: light gray)                                                                          48.2                                                63

                                                                                             63

                                                                                             72

Y92F-76 Flush Mounting Adapter

for 27.5 × 52.5 Rectangular Cutout                                                                                                        Panel Cutout

                                                                               Two 4.5 dia. countersunk holes

                                                                                                                                                 Two, M4

                                                         50  38    24.2  22.2                                                   38  27.5

                              RST

(Color: light gray)                                                                    45.2                         4                            52.5

Use the Y92F-76 together with the Y92F-35 Compact                                      48.2

Flush Mounting Bracket.                                                                60

Do not use the Flush Mounting Adapter supplied with          the  Counter.

Y92F-77B Flush Mounting Adapter

for 24.8 × 48.8 Rectangular Cutout

Use mounting bracket supplied with the Counter                                                                                                   Panel cutout

                                                             28.8  24.2  22.2                                                             24.8

                                                                                       45.2                    4                                       48.8

                                                                                       48.2

(Color: light gray)                                                                    53.8                                           Note: The mounting panel

                                                                                                                                                 thickness should be

                                                                                                                                                 between 1 and 5 mm.

                                                                                                                                                                         27
                                                                                                                         H7E@-N@P

Y92S-37 Wire-wrap Terminal (Set of Two Terminals)                                      44.8          Wire-wrap terminal

                                                                                                     (1 × 1 mm)

                                                                             24                                                  22

                                                                                       48            2  5        48.5    17.1

When using the Wire-wrap Terminal, be sure to use the correct wires              Wire           Bit        Sleeve        Wrapped state

and  peripheral  devices.  (The    correct  wires,  bits  and  sleeves  are

shown in the table on the right.)                                            AWG22         2-A          2-B              Normal

                                                                             AWG24         1-A          1-B              Normal

                                                                             AWG26         3-A          1-B              Normal

Y92S-36 Lithium Battery (3 V)                             24.5 dia.

                                                    7.7

                                                                                                                                        28
                                                                                                                                           H7E@-N@P

Precautions (Common)

Refer to Safety Precautions for All Counters.

■ New H7E (Except for PCB-mounting Counter)

                              !WARNING                                                                              !CAUTION

This product has a built-in lithium battery. Do not short-circuit the +             If a voltage other than the rated one is applied, internal elements may

and − terminals, charge, disassemble, deform, or expose the battery                 be damaged.

to fire. The battery may explode (break), catch fire, or cause liquid               Do not use the Counter in the following places:

leakage.                                                                            • Locations subject to direct sunlight.

Do not use any battery other than the specified one (Y92S-36). Using                • Locations subject to corrosive gases.

another battery may cause liquid leakage or breakage, resulting in                  • Locations subject to dust.

malfunction or injury.

Before Use                                                                          Reset Input and Count/Timer Input

• An insulation sheet has been inserted to maintain the quality of the              • The H7E operates using its built-in Battery. If the H7E is connected

   Totalizer  in  the  event  of  a     long   period  without  use.  Be  sure  to     to a device that has +V and OUT terminals that are connected with

   remove this sheet before attempting to use the product.                             a diode as shown in the circuit diagram, the circuit indicated by the

   Remove the insulation sheet and press the Reset Key on the front                    arrow 1 or 2 will be formed when the device is turned OFF. As a

   panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H), models,                    result, the H7E may be reset or count by one. It is recommended

   “0” or “0.0” will be displayed after 1 s.)                                          that such devices not be connected to the H7E.

                                  Insulation Sheet                                                                  Devices

                                                                                                                                           H7E@-N

                                                                                                 Internal  circuit                         Count/Timer

                                                                                                                                           input or reset

                                                                                                                                           input

                                                       Reset Key

•  Switch settings on the Counter must be performed before mounting                 •  If an excessive voltage is applied to the count/timer input or reset

   it to a control panel.                                                              input terminals, the internal elements may be damaged.

•  Do not use the Counter in the following locations:                                  Ensure that the following voltages are not exceeded:

   • Locations subject to severe changes in temperature.                               • PNP/NPN universal voltage input model: 30 VDC

   • Locations subject to condensation as the result of high humidity.                 • AC/DC voltage input model:

                                                                                       At count/timer input: 240 VAC (peak voltage: 338V)

Mounting Precautions for Flush                                                                                      240 VDC

                                                                                       At reset input:              No       voltage  can  be  applied.    (No-voltage

Mounting                                                                                                            input)

                                                                                       • No-voltage input model: No voltage can be applied.

Although the operating section is watertight (conforming to NEMA4,                  •  Avoid wiring close to high-tension or large-current lines.

IP66), rubber packing is provided to avoid water leakage through the

gap between the Counter and panel cutout. Unless this rubber pack-                  •  Do not remove the outer case when voltage is being applied to the

ing is tightly squeezed on, water may permeate inside the panel.                       power supply terminals or the input terminals.

Therefore, be sure to tighten the screws for fixing the Y92F-34 Flush               •  The input for the H7E@-NFV-@ is a high-impedance circuit and so

Mounting Bracket. (Excessive tightening may also deform the rubber                     influence from an induced voltage may result in malfunction. There-

packing.)                                                                              fore, when the input signal wiring is longer than 10 m (line capaci-

                                                                                       tance of 120 pF/m, at room temperature), it is recommended that a

Screw for the Flush Mounting Bracket                                                   CR filter or a bleeder resistor is connected.

                       The wider side must     Y92F-34 Adapter

                       face the panel.

                                        Panel

                                                                                                                                                              29
                                                                                                                       H7E@-N@P

Count Input, Timer Input or Reset Input                                  AC/DC Multi-voltage Input Models

to More than One H7E Counter at a                                        • When connecting count/timer input from an SSR to the Counter

                                                                         that operates with AC/DC voltage input, use OMRON’s G3TA-IA/ID

Time                                                                     SSR (for DC) whose leakage current is 0.1 mA max. or connect a

                                                                         bleeder resistor in parallel to the input circuit of the Counter.

• PNP/NPN Universal DC Voltage Input

                                                                                       or       Leakage current:

                                                                                                0.1 mA max.

                                                                                                or

                                                                                       or

                                      or                                               *Bleeder resistor

                                                                                       The voltage between terminals 1 and 2 must be

                                                                                       1.5 V maximum when the SSR is OFF.

                                                                         Backlight Power Supply

                                          or                             • To reduce variation in the brightness of the backlight when using

                                                                         more than one H7E with a backlight, use the same power supply for

                                                                         all the backlights.

Note: H (Reset ON) level must be 4.5 V minimum.

H=        4.7 (kΩ)/N + V

          4.7 (kΩ)/N + R

• No-voltage Input                                                       • When connecting the DC power supply for the backlights, be sure

                                                                         to connect the polarities correctly.

                                                    or                   Input Verification with the H7ET Time

                                                                         Counter

Note: 1.  The leakage current of the transistor used for input must be

          less than 1 µA.                                                (When the time range is not set to 0s to

2.        The forward voltage of the diode must be as low as possible    999h59min59s)

          (i.e., 0.1 V maximum with an IF of 20 µA) so that the voltage

          between terminals 3 and 4 will be 0.5 V when the reset input   The decimal point of the LCD blinks every other second while an

          is ON.                                                         input signal is being applied. If the decimal point is not blinking, the

                                                                         input signal is not being received correctly. Check the input signal

Input and Power Supply                                                   connections.

No-voltage Input Models                                                  Unit Label for Time Counter and

• Do not impose voltage on the Counter if the Counter is a model that    Tachometer

operates with no-voltage input, otherwise the internal circuit of the    A unit label has been packed with the Counter. Use in accordance

Counter may be damaged.                                                  with the application.

Do not connect any single input signal in parallel to Counter models

operating with no-voltage input and those operating with voltage

input, otherwise the Counters may malfunction.

• When connecting a sensor to the Counter that operates with no-

voltage input, make sure that the sensor has open collector output.

                    Sensor

                                                                         Battery Replacement

                                                                         Remove the wiring when replacing the Battery. Do not come in con-

                            1  2      3   4                              tact with any item to which high voltage is being applied. Doing so

                                                                         may result in electric shock.

• When connecting an open collector input from a transistor to the       Before changing the Battery, the person should ensure that they are

Counter that operates with no-voltage input, make sure that the          not carrying any static electric charge.

leakage current of the transistor is 1 µA maximum.                       Procedure for replacing the Battery (refer to the diagrams below):

No-voltage Input and PNP/NPN Universal DC                                1.  Using the tool, pry open the lift-tab on the case. (1)

Voltage Input Models                                                     2.  Pull the body out of its outer case. (2)

• The operation of the Counter may be affected if the capacitance of     3.  Lift the Battery up by the edge and remove it. (3)

input lines exceeds 500 pF (about 10 m, with parallel wires of 2 x           When removing the Battery, do not come in contact with the dis-

2 mm).                                                                       play area or any internal parts.

Keep all wires as short as possible. When using shielded wire, line      4.  Wipe the back of the new Battery before inserting it.

capacitance may occur.                                                   5.  Ensure that the + and – terminals are correctly oriented.

                                                                         6.  After replacing the Battery, re-insert the body into its case. (4)

                                                                             Check that the case is securely held in by the lift-tab.

                                                                                                                                                   30
                                                                                                                            H7E@-N@P

7.  Press  the  Reset  Key before    use  (not  necessary for H7ER-N,-NV,-     EN/IEC Standards

    NV1).  (5)

                                                                               The count or timer input, reset input, and backlight power supply ter-

                       Tool                               (2)                  minals of the no-voltage input or PNP/NPN universal DC voltage

                       (1)                                                     input   models  (H7E@-N,-N1,  H7E@-NV(-H),-NV1(-H))           are  not  iso-

                                                                               lated.

                                                                               A  SELV    power  supply  conforming  to  Appendix  H     of  IEC61010-1

                                                                               should be used for the count or timer input, reset input and backlight

                                                                               power supply terminals. A SELV power supply is a power supply for

                                                                               which the input and output have double or reinforced insulation, and

                                (1)                                            for which the output voltage is 30 Vrms with 42.4 V peak or 60 VDC

                                                                               max. (Only the H7E@-NV@-H has a backlight.)

                                                          Battery              The terminals for count or timer input and reset input for AC/DC

                                          (3)

                                                                               multi-voltage input models have basic insulation.

                                                                               Connect the reset input terminals to a device that does not have

                                     (4)                                       exposed current-carrying parts and has basic insulation for 240 VAC.

                                                                               Others

                                                                               If the indicator keeps flickering or is OFF, the internal battery may be

                                                                               close to the end of its service life. In such a case, it is suggested that

                                                                               the battery be replaced.

                 (5)

■ PCB-mounting Counter

Power Supply                                                                   Battery Replacement

• Use the power supply within the applicable range indicated by the            To prevent unwanted reset when replacing the battery, connect the

   following waveform, while considering the ripple and voltage fluctu-        new battery before disconnecting the old one. Otherwise, the voltage

   ations of the circuit power source.                                         supplied to the counter circuit drops, causing the present count value

                                                                               to reset.

    Voltage                                                        3.6 V       When designing the circuit board, providing two extra terminals for

                                                                               battery connection will make the switch must simpler. See the sche-

                                                                   2.6 V       matic diagram below:

•  The H7E@-N@P changes its mode as shown                 below depending  on

   the applied supply voltage.                                                                 H7E@-N@P

                       LCD              Internal circuit

                                        operation

           (V)                                                                 Wiring polarity must be carefully observed, in order to prevent per-

                      Beyond supply voltage                                    manent damage to the Counters. Exercise caution when inserting

           3.6                                                                 the Counter in the socket, to prevent reversed polarity.

                 Looks darker                             Applicable

           3                         Normal operation     range

                 Looks normal

    Approx. 2.6  Flashes             Normal operation     Battery life

    Approx. 2.2  No display          No operation         guideline

           0

                                                                                                                                                           31
                                                                                                                                  H7E@-N@P

Inputs                                                                       PC Board (Bad Example)             PC Board (Good Example)

Do not route the wiring of the count, timer, or reset inputs in the vicin-                  H7E@-N@P

ity of, or in parallel to the wiring of high-voltage or inductive load cir-

cuits (such as motors and relays). Also, keep the wiring as short as                      Placed far away from                     Large-current-

possible.                                                                                 the power supply.                        consuming

                                                                                                                                   components

                                                                                            Large-current-

                                                                                            consuming

                                                                                            components

                                                                                          Wired in parallel

                                                                                          with large-

                                                                                          current-carrying                         H7E@-N@P

                                                                                          components.

                                                                                            Bypass                                 Bypass

                                                                                            capacitor                              capacitor

    H7E@-N@P                                                                 Power supply                           Power supply

                                                                             When using the Counter in an environment where the Counter is

                                                                             subject  to  frequent     occurrences  of  vibration  or  shock,      or  when

                                                                             mounting the Counter facing downwards or sideways, it is suggested

Be careful not to apply voltages exceeding the following values to the       that the Counter be directly soldered to a PCB instead of using sock-

count, timer, or reset terminals, otherwise the internal circuit may be      ets.

damaged.

No-voltage input: 3 VDC                                                      To Conform to EN/IEC Standards

General Information                                                          Input terminals have no insulation from power supply terminals. The

                                                                             power supply terminals must be supplied from a SELV source in

                                                                             accordance with IEC61010-1 Annex H. SELV (separated extra-low

Finish soldering under the conditions below.                                 voltage) source is a power supply having double or reinforced insula-

Solder the terminals within 5 seconds, at a solder iron tip tempera-         tion between the primary and the secondary circuit and having out-

ture of 250°C ± 10°C when using lead solder, and within 3 seconds,           put voltage of 30 V rms max. and 42.4 V peak max. or 60 VDC max.

at a solder iron tip temperature of 350°C ± 10°C when using lead-

free solder.                                                                 Cleaning

Since the Counter is not flux-tight, do not use flux when soldering.         To prevent damage, the exterior of the Counter must not be exposed

Avoid automatic and dip soldering. Manually solder the Counter onto          to organic solvents (3.g. paint thinner or benzine), strong alkalis, or

a PC board, and avoid cleaning as much as possible.                          strong acids.

When mounting the Counter on a PC board with components which                Others

consume higher current than the H7E@-N@P, observe the following

precautions.                                                                 • No user-serviceable parts.

1.  Minimize the wiring (less than 50 mm) from the H7E@-N@P to the           • Return to OMRON for all repairs.

    power supply section.

2.  Avoid placing the H7E@-N@P power, timer, counter, or reset input

    circuit in parallel with circuits that consume large currents, partic-

    ularly on the positive side.

              ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

              To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                  In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                             32
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2015.7

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2015 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

H7ET-NFV-B  H7EC-N-B    H7ET-NFV1-B  H7ET-N1-B  H7ET-NV1-B  H7ET-NV-BH  H7ET-N-B  H7EC-NFV-B  H7EC-

NV-B  H7EC-NV-BH  H7ET-NV-B  H7ET-NV1-BH  H7ET-N  H7ET-NFV1  H7EC-N-B-601  H7EC-NP

小广播

H7EC-N-B-601器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved