H7CX-A-N-AC100-240

器件型号:H7CX-A-N-AC100-240
器件类别:机电产品    工业自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

General Purpose Relays 8 PIN DPDT 120VAC

参数

产品属性属性值
产品种类:
Product Category:
Counters & Tachometers
制造商:
Manufacturer:
Omron
RoHS:YES
产品:
Product:
Counters
类型:
Type:
1 Stage and Total Preset Counter
Accuracy:+/- 0.1 %
Display Type:6 Digit
Voltage:100 VAC to 240 VAC
商标:
Brand:
Omron Automation and Safety
Frequency Response:50 Hz
系列:
Series:
H7CX-N
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
1825557
单位重量:
Unit Weight:
4.585615 oz

H7CX-A-N-AC100-240器件文档内容

   New Product

   Multifunction Counter/Tachometer

   H7CX-@-N

Ultra-compact Counter Provides More

Complete Functionality.

Basic Features

• Short body with depth of only 59 mm (for 12 to 24-VDC Models with Screw Terminals).*1

• Better readability with character height of 12 mm on 4-digit models and 10 mm

   on 6-digit models.

• The present value display characters can be switched between red, green, and orange.*2

Safety and Reliability

• New set value limit and counter functions have been added.

Other Features

• Front Panel can be changed to white or light gray.*3

• New models with two tachometer inputs and two tachometer outputs have

   been added to the series.*4

*1.For 100 to 240-VAC Models with Screw Terminals: 78 mm, Models with Sockets: 63.7 mm                          For the most recent information on models that have been certified for

   (case dimension).                                                                                            safety standards, refer to your OMRON website.

*2.The H7CX-A11 and H7CX-R11 have only red characters.

*3.The Front Panel can be replaced with an optional Front Panel (except for Tachometer-only Models).                    Refer to Safety Precautions on page 52.

*4.Only one prescale value provided.

Features

Basic Features                                                                                        Safety and Reliability

Ultra Short Body                                                                                      Isolated Power Supply and Input Circuits

The body depth has been greatly reduced. Helps in making thinner control panels.                      Power supply circuit and input circuits are isolated inside the Counter/

12 to 24-VDC Models with Screw Terminals: 59 mm                                                       Tachometer. Previous non-isolated counters had wiring restrictions

100 to 240-VAC Models with Screw Terminals: 78 mm*                                                    and could be damaged if wired incorrectly. The H7CX removes these

Models with Sockets: 63.7 mm (case dimension)                                                         worries.

*  Power supply circuit and input circuits are isolated for safety and reliability.                   Note: Except 12 to 24-VDC models.

                                                                                                      Set Value Limit

                                                                                                      You can set an upper limit for the set value to prevent unexpected

                                                                                                      operation of output devices caused by setting mistakes.

                          New models             Previous

                                                 models

Easier to Read

For better readability, the character height for the present value

display is 12 mm on models with 4 digits, the largest class in the

industry. The wide viewing angle and brightness provide excellent

visibility. The number of display segments has also been increased to

make settings easier to understand, and the present value display                                                       Setting the upper limit of the set

can be switched between red, green, and orange so that output status                                                    value enables worry-free operation.

can be seen from a distance.                                                                                            No overflow

Model with 4 Digits    Model with 6 Digits                                                            For 1,000 pieces

         12 mm                  10 mm            New       Previous

         (actual size)    (actual size)          models models

                                                                                                      Output Counter

                                                                                                      The output counter counts the number of times the output turns ON

                      (Display example)             Easy to read from the top, bottom,                (alarms can be displayed and the count can be monitored in

                                                    and sides!                                        increments of 1,000 operations). This counter is useful in managing

Note: The display color can be switched on all models except for the                                  the service life of the Counter/Tachometer or the load.

   H7CX-A11 and H7CX-R11.

The Easiest Operation

Operation is simplified by the        Model with 4 Digits            Model with 6 Digits

Up/Down Key for each digit

on 4-digit models and Up

Key for each digit on 6-digit

models.

                                                                                                                                                                                        1
   H7CX-@-N

   Other Features                                                               Key Protection

   The front color can be changed simply by                                     Select from any of seven protection patterns. Use the best one for the

   replacing the Front Panel.                                                   application.

   The Front Panel can be replaced with an optional Front Panel (sold           New Functions

   separately) with a different color to match the installation site. Select    Many useful functions have been added, including a Twin Counter

   from black, white, and light gray (except for models with tachometer         Mode and many tachometer functions to handle even more

   function only).                                                              applications.

                                                                                New Tachometer Functions

                                                                                •  Control with two independent inputs (independent measurements,

                                                                                   differential, absolute ratio, and error ratio)

                                                                                •  Peak/bottom hold function

                                                                                •  Output hysteresis setting

                                   White                  Light gray            •  Output OFF delay

             Black                                                              •  Switching the measurement method (pulse cycle/pulse width)

             (Standard)                                                         •  Startup time

                                          Only the Front

                                          Panel can be                          •  Auto-zero time

                                          replaced.                             •  Averaging method/Number of averaging times

   Universal NPN/PNP Input                                                      •  AMD-compatible Mode

                                                                                Note: Refer to “Model Configuration” below, for details on applicable

   DC 2-wire sensors can be connected for a wide range of input                                functions.

   devices.

   Waterproof, Dust-proof Structure (UL508 Type

   4X and IP66)

   Worry-free application is possible in locations subject to water.

   Note: When the Y92S-29 Waterproof Packing is used.

   Model Number Structure

   Model Configuration

                                                                                H7CX Series

                                          H7CX-A-series Multifunction           Preset Counter                      H7CX-R-series Digital Tachometer

   Model

   Classification                                  Preset counter               Preset counter/tachometer                        Tachometer

   Model                           H7CX-A@-N              H7CX-A4W@-N           H7CX-AW@-N/-AU@-N                   H7CX-R11@-N              H7CX-R11W@-N

             1-stage preset               Yes                         Yes                      Yes                                 No

             counter

             2-stage preset               No                          Yes                      Yes                                 No

             counter

             Total and preset             Yes                         Yes                      Yes                                 No

   Function  counter

             Batch counter                No                          Yes                      Yes                                 No

             Dual counter                 No                          Yes                      Yes                                 No

             Twin counter                 No                          Yes                      Yes                                 No

             Tachometer                   No                          No                       Yes*1                               Yes

                                                                                               Yes

                                                                                               1 input or 2 inputs                           Yes

   Tachometer input                       No                          No                       (independent         Yes                2 inputs (independent

                                                                                measurements, differential,         1 input             measurement) only

                                                                                absolute ratio value, and

                                                                                               error ratio value)

   Settings                               1-stage                               2-stage                                            1-stage

   External connections            11-pin socket                              Screw terminals                                11-pin socket

   Display color of present value  Red                                Red, green, or orange                                        Red

   Display digits                  4 or 6 digits                      4 digits                 6 digits                            6 digits

   *1.  Set the tachometer input mode from the function setting mode to switch to the tachometer function.

2
                                                                                                                                                          H7CX-@-N

Model Number Legend                                   (Not  all possible combinations of functions are available.)

   H7CX-@@@@@@-N

               1  2  3     4    5  6

1. Type                                                            2. External connections                                       3. Digits

   Symbol                       Meaning                                Symbol                  Meaning                           Symbol                   Meaning

   A                       Standard type                               None                 Screw terminals                      None                     6 digits

   R                       Tachometer                                  11                   11-pin socket                            4                    4 digits

4. Settings                                                        5. Output type                                                6. Supply voltage

   Symbol                       Meaning                                Symbol                  Meaning                           Symbol                   Meaning

   None                    1-stage setting                             None    Contact output or contact       output  +         None       100 to 240 VAC at 50/60 Hz

   U              Factory-set to 1-stage setting                                            transistor output                        D                   12 to 24 VDC

   W              Factory-set to 2-stage setting*                      S                    Transistor output                    D1         12 to 24 VDC/24 VAC at 50/60 Hz

*  The H7CX-R11W@ is a 1-stage (2 inputs and outputs)

   rather than a 2-stage Counter.

Note: Estimates can be provided for coatings                and  other specifications that are not given in the datasheet.       Ask your OMRON representative for details.

Ordering Information

List of Models

   Type        Classification         Configuration         External           Settings     Display            Outputs                      Power supply               Model

                                                            connections                     digits                                          voltage

                                                                                                       Contact output (SPDT)            100 to 240 VAC        H7CX-A114-N

                                                                                            4 digits   Transistor output (SPST)                               H7CX-A114S-N

                                                                                                       Contact output (SPDT)            12 to 24 VDC/24 VAC   H7CX-A114D1-N

                                                            11-pin socket                              Contact output (SPDT)            100 to 240 VAC        H7CX-A11-N

                                                                                            6  digits  Transistor output (SPST)                               H7CX-A11S-N

                                                                                                       Contact output (SPDT)            12 to 24 VDC/24  VAC  H7CX-A11D1-N

                                   • 1-stage preset                                                    Transistor output (SPST)                               H7CX-A11SD1-N

                                      counter                                  1-stage                 Contact output (SPDT)                                  H7CX-A4-N

                                   • Total and preset                                                                                   100 to 240 VAC

                                      counter                                               4  digits  Transistor output (SPST)                               H7CX-A4S-N

                                                                                                       Contact output (SPDT)            12 to 24 VDC          H7CX-A4D-N

               Preset counter                                                                          Transistor output (SPST)                               H7CX-A4SD-N

                                                                                                       Contact output (SPDT)            100 to 240 VAC        H7CX-A-N

                                                                                            6  digits  Transistor output (SPST)                               H7CX-AS-N

                                                                                                       Contact output (SPDT)            12 to 24 VDC          H7CX-AD-N

                                                                                                       Transistor output (SPST)                               H7CX-ASD-N

   H7CX-A                          •  1-stage preset                                                   Contact output (SPST + SPDT)     100 to 240 VAC        H7CX-A4W-N

   Series                             counter

                                   •  2-stage preset

                                      counter

                                   •  Total and preset      Screw                           4 digits   Transistor output (DPST)         12 to 24 VDC          H7CX-A4WSD-N

                                      counter               terminals

                                   •  Batch counter

                                   •  Dual counter

                                   •  Twin counter

                                                                                                       Contact output (SPST + SPDT)     100 to 240 VAC        H7CX-AW-N

                                   •  1-stage preset                           2-stage                 Transistor output (DPST)                               H7CX-AWS-N

                                      counter                                                          Contact output (SPST + SPDT)                           H7CX-AWD1-N

                                   •  2-stage preset                                                                                    12 to 24 VDC/24 VAC

                                      counter                                                          Transistor output (DPST)                               H7CX-AWSD1-N

               Preset counter/     •  Total and preset                                      6 digits                                    12 to 24 VDC          H7CX-AWSD-N

               Tachometer             counter                                                          Contact output (SPDT) +

                                   •  Batch counter                                                    Transistor output (SPST)         100 to 240 VAC        H7CX-AU-N

                                   •  Dual counter

                                   •  Twin counter                                                     Contact output (SPDT) +                                H7CX-AUD1-N

                                   •  Tachometer                                                       Transistor output (SPST)         12 to 24 VDC/24 VAC

                                                                                                       Transistor output (DPST)                               H7CX-AUSD1-N

                                                                               1-stage                                                  100 to 240 VAC        H7CX-R11-N

                                                                             (1 input and              Contact output (SPDT)            12 to 24 VDC/24 VAC   H7CX-R11D1-N

   H7CX-R      Tachometer          • Tachometer             11-pin socket      output)      6 digits

   Series                                                                      1-stage                                                  100 to 240 VAC        H7CX-R11W-N

                                                                             (2 inputs and             Contact output (SPDT + SPST)     12 to 24 VDC/24 VAC   H7CX-R11WD1-N

                                                                               outputs)

Note: 1.       The functions that are provided depend on the model. Check detailed specifications before ordering.

           2.  Refer to page page 37 and later for information on H7CX-R Tachometers.

                                                                                                                                                                              3
   H7CX-@-N

   Accessories (Order Separately)

   Front Panels (Replacement Part)

             Model                Color                Applicable Counters        Page

   Y92P-CXC4G         Light gray (5Y7/1)            4-digit Counter

   Y92P-CXC4S         White (5Y9.2/0.5)

   Y92P-CXC4B         Black (N1.5)

                                                                                  12

   Y92P-CXC6G         Light gray (5Y7/1)            6-digit Counter

   Y92P-CXC6S         White (5Y9.2/0.5)

   Y92P-CXC6B         Black (N1.5)

   Note: 1.  You can change the color of the Front Panel when mounting the Counter. The  Counter  is  shipped  with  a     black  (N1.5) Front  Panel.

   2.        "COUNTER" is printed on the front of Replacement Front Panels.

   Soft Cover

             Model                       Remarks                     Page

   Y92A-48F1          ---                                            12

   Hard Cover

             Model                       Remarks                     Page

             Y92A-48  ---                                            12

   Flush Mounting     Adapter

             Model                       Remarks                     Page

             Y92F-30  Included with models with screw

                      terminals.

                      Use this Adapter to install the Counter/       12

             Y92F-45  Tachometer in a cutout previously made

                      for a DIN 72 × 72 mm device (panel

                      cutout: 68 × 68 mm).

   Waterproof Packing

             Model                       Remarks                     Page

             Y92S-29  Included with models with screw                12

                      terminals.

   Connection Sockets

                                                                     Connectable

             Model                  Classification                   Counter/                     Remarks                         Page

                                                                     Tachometers

   P2CF-11            Front-connecting Socket                                     ---

                      Front-connecting Socket (Finger-safe                        Round crimp terminals cannot be used on

   P2CF-11-E          Type)                                                       Finger-safe Sockets.

                                                                     H7CX-@11@-N  Use forked crimp terminals.                     13

                                                                                  A Y92A-48G Terminal Cover can be used

   P3GA-11            Back-connecting Sockets                                     with the Socket to create a finger-safe

                                                                                  construction.

   Terminal Covers for P3GA-11 Back-connecting Socket

             Model                       Remarks                     Page

   Y92A-48G           ---                                            13

4
                                                                                                                                                                        H7CX-A@-N

      H7CX-A@-N Multifunction Preset Counter

• Easy to check the output status from a long distance with

     changing display colors*1 (red, green, and orange).

• Includes total and preset counter, batch counter, dual counter,

     twin counter, and tachometer.*2

*1.  Not supported by the H7CX-A11@-N.

*2.  The functions that can be selected depend on the model.

                                                                                                                 For the most recent information on models that have been certified for

                                                                                                                 safety standards, refer to your OMRON website.

Specifications

Ratings

Item                  Models  H7CX-A114@-N                          H7CX-A11@-N             H7CX-A4@-N             H7CX-A@-N                       H7CX-A4W@-N            H7CX-AW@-N/-AU@-N

Classification                Preset counter                                                                                                                              Preset counter/

                                                                                                                                                                          tachometer

                                                                                                                                             1-stage/2-stage preset       1-stage/2-stage preset

                                                                                                                                             counter, total and preset    counter, total and preset

Configuration                 1-stage preset counter, 1-stage preset counter with total counter (selectable)*1                               counter*1, batch             counter*1, batch

                                                                                                                                             counter, dual counter,       counter, dual counter,

                                                                                                                                             and twin counter             twin counter, and

                                                                                                                                             (selectable)                 tachometer (selectable)

                                                                                                                                                                          • 100 to 240 VAC at 50/

            Power supply      • 100 to 240 VAC, 50/60 Hz                               • 100 to 240 VAC, 50/60 Hz                                                         60 Hz

            voltage*2         • 24 VAC, 50/60 Hz or 12 to 24 VDC                       • 12 to 24 VDC                                                                     • 24 VAC at 50/60 Hz or

                                                                                                                                                                          12 to 24 VDC

                                                                                                                                                                          • 12 to 24 VDC

Ratings     Operating volt-

            age fluctuation   85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)

            range

            Power con-        Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at 12 to 24 VDC

            sumption

Mounting method               Flush mounting or surface mounting                       Flush mounting

External connections          11-pin socket                                            Screw terminals

Degree of protection          IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29 Waterproof Packing is used.

Input signals                 CP1, CP2, reset, and total reset                                                                               CP1, CP2, reset 1, and reset 2

            Maximum           30 Hz (minimum pulse width: 16.7 ms) or 5 kHz (minimum pulse width: 0.1 ms) (selectable) (ON/OFF ratio 1:1)*3

            counting speed    *Common setting for CP1 and CP2

            Input mode        Increment, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs))

Counter     Output mode       N, F, C, R, K-1, P, Q, A, K-2, D, and L.                                                                       N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.

            One-shot out-     0.01 to 99.99 s

            put time

            Reset system      External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)

Tachometer                    Refer to the separate table for tachometer function ratings.

Prescaling function           Yes (0.001 to 9.999)           Yes (0.001 to 99.999)     Yes (0.001 to 9.999)        Yes (0.001 to 99.999)     Yes (0.001 to 9.999)         Yes (0.001 to 99.999)

Decimal point adjustment      Yes (rightmost 3 digits)

Sensor waiting time           290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)

                              No-voltage inputs:

                              ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)

                              ON residual voltage: 3 V max.

Input method                  OFF impedance: 100 kΩ min.

                              Voltage input:

                              High (logic) level: 4.5 to 30 VDC

                              Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)

                              No-voltage input/voltage input (selectable)

External power supply         12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to Precautions for Correct Use on page page 53 for details.

Control output                • Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)

                              • Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max.

                              7-segment, negative            7-segment, negative       7-segment, negative         7-segment, negative       7-segment, negative          7-segment, negative

                              transmissive LCD               transmissive LCD          transmissive LCD            transmissive LCD          transmissive LCD             transmissive LCD

                              Character height               Character height          Character height            Character height          Character height             Character height

Display*4                     Count value: 12 mm             Count value: 10 mm        Count value: 12 mm          Count value: 10 mm        Count value: 12 mm           Count value: 10 mm

                              (red)                          (red)                     (red, green, or orange      (red, green, or orange    (red, green, or orange       (red, green, or orange

                              Set value: 6 mm (green)        Set value: 6 mm (green)   selectable)                 selectable)               selectable)                  selectable)

                                                                                       Set value: 6 mm (green)     Set value: 6 mm (green)   Set value: 6 mm (green)      Set value: 6 mm (green)

                              4 digits                       6 digits                  4 digits                    6 digits                  4 digits                     6 digits

Digits                        −999 to 9999                   −99999 to 999999          −999 to 9999                −99999 to 999999          −999 to 9999                 −99999 to 999999

                              (−3 digits to +4 digits)       (−5 digits to +6 digits)  (−3 digits to +4 digits)    (−5 digits to +6 digits)  (−3 digits to +4 digits)     (−5 digits to +6 digits),

                                                                                                                                                                          tachometer: 0 to 999999

Memory backup                 EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.

Operating temperature         −10 to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)

range

Storage temperature range     −25 to 70°C (with no icing or condensation)

Operating humidity range      25% to 85%

Case color                    Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light gray or white.)

                                                                                                                                                                          Flush mounting adapter,

Attachments                                             ---                            Flush mounting adapter, waterproof packing, terminal cover                         waterproof packing,

                                                                                                                                                                          terminal cover, label for

                                                                                                                                                                          DIP switch settings

*1.  1-stage preset counter and total counter functionality.

*2.  Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.

*3.  A response of 10 kHz (minimum pulse width: 0.05 ms) is possible if the response speed is 5 kHz and the 1-stage preset counter input mode is increment,

     decrement, or increment/decrement (command input).

*4.  The display is lit only when the power is ON. Nothing is displayed when power is OFF.

                                                                                                                                                                                                     5
   H7CX-A@-N

   Tachometer Function Ratings

                      Model   H7CX-A114@-N

                              H7CX-A11@-N

                              H7CX-A4@-N                                                                       H7CX-AW@-N/-AU@-N

                              H7CX-A@-N

      Item                    H7CX-A4W@-N

      Input mode                                        Selectable from independent measurements for 1 or 2 inputs, differential input for 2 inputs, absolute ratio for 2 inputs, and error ratio

                                                        for 2 inputs.

      Pulse measurement                                 Periodic measurement                                                    Pulse width measurement

      method

                                                                                         1-input mode:                                                                            1-input mode:

      Maximum counting                                  30 Hz                            10 kHz (minimum pulse width: 0.05 ms)  30 Hz                                             10 kHz (minimum pulse width: 0.05 ms)

      speed                                             (minimum pulse width: 16.7 ms)   Other modes:                           (minimum pulse width: 16.7 ms)                    Other modes:

                                                                                         5 kHz (minimum pulse width: 0.1 ms)                                                      5 kHz (minimum pulse width: 0.1 ms)

      Minimum input                                     ---                              ---                                    30 ms*1                                           1-input mode: 0.2 ms

      signal width                                                                                                                                                                Other modes: 0.4 ms*

      Measuring ranges                                  0.001 to 30.00 Hz                1-input mode: 0.001 to 10 kHz,         0.030 to 999999 s                                 1-input mode: 0.0002 to 99999 s

                              No tachometer                                              Other modes: 0.01 to 5 kHz                                                               Other modes: 0.0004 to 99999 s

                              functionality                                              200 ms min. or continuous

      Sampling period                                   200 ms min.                      selectable (minimum interval of        Continuous (minimum                     interval  of 10 ms)

                                                                                         10 ms)

      Measuring accuracy                                ±0.1% FS ±1 digit max. (at 23 ±5°C)

                                                        Input mode:

      Output mode                                       Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO

                                                        2-input independent measurement: HI-HI, LO-LO

      Auto-zero time                                    0.1 to 999.9s

      Startup time                                      0.0 to 99.9s

      Averaging                                         Simple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16 times

      Hold input                                        Minimum input signal width: 20 ms

   *  An input OFF time of at least 20 ms is required.

   Characteristics

      Insulation resistance           100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-                       Life-test Curve                                     (Reference

                                      current-carrying metal parts, and between non-continuous contacts                                  Values)

                                      2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-                            Resistive load

                                      current-carrying metal parts

                                      2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models                    No. of operations ( ×103)  1,000

      Dielectric strength             except H7CX-@D@ (1,000 VAC for 24 VAC/12 to 24 VDC)

                                      1,000 VAC (for H7CX-@SD@), 50/60 Hz for 1 min between control output, power                                                       700

                                      supply, and input circuit (2,000 VAC for models other than H7CX-@SD@)

                                      1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts                                                                     500

                                      3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC or 12

      Impulse withstand voltage       to 24 VDC)                                                                                                                        300

                                      4.5 kV between current-carrying terminals and exposed non-current-carrying metal                                                                       30 VDC (cosφ=1)

                                      parts (1.5 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC)

                                      ±1.5 kV between power terminals (±480 V for models with 12 to 24 VDC)

      Noise immunity                  ±600 V between input terminals

                                      Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)                                                                  250 VAC (cosφ=1)

      Static immunity                 Malfunction: 8 kV                                                                                                                 100

                                      Destruction: 15 kV

      Vibration     Destruction       10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each                                                   70

      resistance    Malfunction       10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each                                                50

                                                                                                                                                                               0  1                 2         3          4

      Shock re-     Destruction       300 m/s2 each in three directions                                                                                                                                Load current      (A)

      sistance      Malfunction       100 m/s2 each in three directions

                                      Mechanical: 10,000,000 operations min.                                                                 Inductive load

      Life expectancy                 Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient                           No. of operations ( ×103)  1,000

                                      temperature condition: 23°C)*

      Weight                          Approx. 130 g (Counter only)                                                                                                      700

   *  Refer to the Life-test Curve.                                                                                                                                     500

   Applicable Standards                                                                                                                                                 300

                    cULus (or cURus): UL508/CSA C22.2 No. 14*                                                                                                                        30 VDC (L/R=7 ms)

      Approved      EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II

      safety        B300 PILOT DUTY

      standards     1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3 A resistive load

                    VDE0106/P100 (finger protection)

                    (EMI)                                      EN61326                                                                                                  100

                                                                                                                                                                                  250 VAC (cosφ=1)

                    Emission  Enclosure:                       EN 55011 Group 1 class A                                                                                 70

                    Emission  AC mains:                        EN 55011 Group 1 class A

                    (EMS)                                      EN61326                                                                                                  50

                    Immunity  ESD:                             EN 61000-4-2:  4 kV contact discharge;                                                                          0  1                 2         3          4

                                                                              8 kV air discharge                                                                                                       Load current (A)

                    Immunity  RF-interference:                 EN 61000-4-3:  10 V/m (Amplitude-modulated, 80 MHz to 1

      EMC                                                                     GHz);                                                      A current of 0.15 A max. can be switched at 125

                                                                              10 V/m (Pulse-modulated, 900 MHz ±5 MHz)                   VDC (cosφ=1) and current of 0.1 A max. can be

                    Immunity  Conducted Disturbance:           EN 61000-4-6:  10 V (0.15 to 80 MHz)                                      switched if L/R=7 ms. In both cases, a life of

                    Immunity  Burst:                           EN 61000-4-4:  2 kV power-line;                                           100,000 operations can be expected.

                                                                              1 kV I/O signal-line

                    Immunity  Surge:                           EN 61000-4-5:  1 kV line to lines (power and output lines);

                                                                              2 kV line to ground (power and output lines)

                    Immunity  Voltage Dip/Interruption:        EN 61000-4-11: 0.5 cycle, 100% (rated voltage)

   *  The following safety standards apply to models with sockets (H7CX-A11@ or H7CX-A114@).

      cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.

      cUR (Recognition): Applicable when any other socket is used.

6
                                                                                                                                 H7CX-A@-N

I/O Functions

Using as a Counter*1

                                   (1) In general (except for Dual Counter Mode)

                                   • Reads counting signals.

         CP1, CP2                  • Increment, decrement, command, individual, and quadrature inputs accepted.

                                   (2) When used as a dual counter or twin counter

                                   • Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.

                                   • Increment signals can be input.

                                   (1) In general (except for Dual Counter Mode)

Inputs                             • Resets present value and outputs (OUT2 when using the batch counter)*2.

                                   • Counting cannot be performed during reset/reset 1 input.

         Reset/reset 1             • Reset indicator is lit while reset input is ON.

                                   (2) When used as a dual counter or twin counter.

                                   • Resets the CP1 present value (to 0).

                                   • Counting for CP1 input cannot be performed while the reset 1 input is ON.

                                   • The reset indicator is lit while the reset 1 input is ON.

         Total reset or  reset  2  The reset function depends on the selected configuration*3.

Outputs  OUT1, OUT2                Outputs signals according to the specified output mode when a set value is reached.

*1.  For information on operation of I/O functions, refer to pages page 22 to page 25.

*2.  In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models,

     and returns to set value 2 with 2-stage models.

*3.  Reset operates as described in the following table. (The reset indicator will not be lit.)

        Configuration                                                    Reset operation

     1-stage/2-stage     Does not operate (not used).

     preset counter

     Total and preset    • Resets the total count value.

     counter             • The total count value is held at 0 while the total reset input is ON.

     Batch counter       • Resets the batch count value and batch output (OUT1).

                         • The batch count value is held at 0 while the reset 2 input is ON.

     Dual counter        • Resets the CP2 present value.

                         • Counting for CP2 input cannot be performed while the reset 2 input is ON.

     Twin counter        • Resets the CP2 present value.

•    The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)

     Minimum reset signal width                       Output delay time

                   1 ms                               0.8 to 1.2 ms

              20 ms                                   15 to 25 ms

Operating Procedures (Tachometer Function)

         CP1, CP2        Reads counting signals. (The CP2 input can be used when the input mode is not 1-input mode.)

                         • Holds the measurement value and outputs. (The reset 2 input can be used when the input mode

                         is 2-input independent measurement.)

Inputs                   • Functions as a hold input.

         Reset/reset 1   The measurement value (displayed value) and the outputs are held while the RST Key on the

                         front panel is pressed.

                         • The reset indicator is lit when the value is being held.

Outputs  OUT1, OUT2      Outputs signals according to the specified output mode when a set value is reached.

                                                                                                                                                                        7
   H7CX-A@-N

   Connections

   Terminal Arrangement

   Confirm that the power supply meets specifications before use.

                    H7CX-A-N/-A4-N                                                                                                H7CX-AD-N/-A4D-N                                                                             H7CX-AS-N/-A4S-N

   1-stage Contact Output                                                                               1-stage Contact Output                                                                                   1-stage Transistor Output

                                                  Reset      CP2                CP1  Total reset                                         Reset         CP2        CP1       Total reset                                                                  Reset       CP2        CP1         Total reset

                                                                                                                               0V

                             0V                                                                                                                                                                                                          0V

      (−)                              6          7          8                  9    10                                            6     7             8          9        10                                             (−)                6           7           8          9           10

      Sensor                                                                                                                                                                                                              Sensor

      (+)                                                                                                                                                                                                                 (+)

              12 VDC                11                                                                                                                                                                                         12 VDC        11

      External                                                                                                                                                                                                            External

      power supply                                                                                                                                                                                                        power supply

                                       1          2          3                  4    5                                             1     2             3          4           5                                                              1           2           3          4           5

                                                                                OUT                                                                            OUT                                                                                                           OUT

                                                                                                                               (−)             (+)

                                                                                                        Terminals 1 and 6 are connected internally.

           H7CX-ASD-N/-A4SD-N                                                                           H7CX-AW-N/-A4W-N/-AWD1-N/-AU-N/-AUD1-N                                                                   H7CX-AWS-N/-AWSD1-N/-AUSD1-N

   1-stage Transistor Output                                                                            2-stage Contact Output                                                                                   2-stage Transistor Output

                             Reset        CP2        CP1           Total reset                                                        Reset 1       CP2        CP1         Reset 2                                                              Reset 1         CP2       CP1      Reset 2

              0V                                                                                                        0V                                                                                                          0V

                6            7            8          9             10                                   (−)                    6      7             8          9        10                                       (−)                     6       7              8         9        10

                                                                                                           Sensor                                                                           *1                   Sensor

                                                                                                        (+)                                                                                                      (+)

                                                                                                                  12 VDC       11                   12                  13                                                12 VDC         11                 12                     13       OUT1

                                                                                                                                                                                            OUT1

                                                                                                        External                                                                                                 External

                                                                                                        power supply                                                                                             power supply

                1            2            3          4             5                                                           1      2             3          4           5                *1: “-AU@” Models                            1       2              3         4          5

                                                  OUT                                                                                                     OUT2                                                *                                                      OUT2

           (−)                      (+)                                                                                                                                                     12         13                           (−)             (+)

   Terminals 1 and 6 are connected internally.                                                                            (−)                  (+)

      H7CX-AWSD-N/-A4WSD-N                                                                                 H7CX-A11-N/-A114-N/-A11D1-N/-A114D1-N                                                                 H7CX-A11S-N/-A114S-N/-A11SD1-N

   2-stage Transistor Output                                                                            1-stage Contact Output                                                                                   1-stage Transistor Output

                    Reset 1         CP2        CP1        Reset 2                                                              Reset                                                                                           Reset

      0V                                                                                                                          CP1                                                                                          CP1

                                                                                                                                  CP2                                                       Internal circuit                   CP2                                              Internal circuit

           6        7               8          9         10                                                               Total reset                          5     6     7                                               Total reset                   5      6    7

                                                                                                                                                          4                         8                                                            4                        8

                                                                                                                                       0V                3                               9                                          0V           3                           9

                                                                                                                   (−)                                      2                 10                                 (−)                                2                   10

                                    12                   13           OUT1                                         Sensor                                         1     11                                       Sensor                                     1      11

                                                                                                                   (+)              12 VDC                                                                       (+)                12 VDC

                                                                                                                          External                                                                OUT                     External                                                          OUT

           1        2               3          4          5                                                               power supply                                                                                    power supply

                                          OUT2                                                                                                                 (−)      (+)                                                                              (−)         (+)

      (−)              (+)

   Terminals 1 and  6 are connected                                internally.

   Transistor Output

   •  The transistor output of the H7CX is isolated from the internal                                                                                                   •     The diode connected to the collector of the output transistor is used

      circuitry by a photocoupler, so the transistor output can be used as                                                                                                    to absorb inverted voltage that is generated when an inductive load

      both NPN and PNP output.                                                                                                                                                is connected to the H7CX.

           NPN Output                                                                PNP Output                                                                                                                  Counter

                                                                                                                                                                                                                                    Inductive

                                                                                                                                                                                                                          +         load

                                                         Load                                     Load

                                               +                                                        +                                                                                                        Power for load

                             Power for load                                                       Power for load

8
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                H7CX-A@-N

Block Diagram                                                                                                                                                                                                                                                                                                                 Input Circuits

                                      (Basic insulation)                                                                                                                                                                                                                                                                      CP1, CP2, Reset/Reset                                                                                                                                                              1, and Total Reset/Reset 2

Output circuit                                                                                                           Power supply                                                                                                                                                                                         Input

                                                                                                                                                               circuit

(Basic insulation)                                                                                                       (See note.)

                                                                                                                                                               Display circuit                                                                                                                                                No-voltage Inputs                                                                                                                                                                     Voltage Inputs (PNP Inputs)

Input circuits                           Internal                                                                                                                                                                                                                                                                             (NPN Inputs)

                                      control circuit                                                                                                                     Key switch

                                                                                                                                                                             circuit                                                                                                                                                                                                                                                                  +14V

                                                                                                                                                                                                                                                                                                                                                                                                                              1 kΩ                                                                                           Approx. 4.7 kΩ                                                                                        Internal

Note: All models except for H7CX-@D-N have                                                                                                                                                               basic      insulation.                                                                                                                                                                                                                                                                                     IN                                                                                                             circuit

                                                                                                                                                                                                                                                                                                                                                      IN                                                                                                            Internal

                                                                                                                                                                                                                                                                                                                                                                                                                                                                    circuit

Input Connections

The inputs of the H7CX-@-N are no-voltage (short-circuit or open)                                                                                                                                                                                                           inputs                                        or  voltage inputs.

No-voltage Inputs (NPN Inputs)

Open Collector                                                                                                                                                 Voltage Output                                                                                                                             Contact Input                                                                                                                                                                                          DC Two-wire Sensor

          PLC or                                                                                                                                                                                         Sensor

          sensor

                      0 V for inputs     Reset/reset 1 input                  CP2 input                       CP1 input             Total reset/reset 2 input                                                    0 V for inputs  Reset/reset 1 input  CP2 input  CP1 input     Total reset/reset 2 input                                                                                                      0 V for inputs     Reset/reset 1 input     CP2 input     CP1 input      Total reset/reset 2 input                                                         0 V for inputs             Reset/reset 1 input             CP2 input                             CP1 input      Total reset/reset 2 input

H7CX-A@            6                  7                       8                          9                               10                                                  H7CX-A@                             6               7                    8          9          10                                            H7CX-A@                                                  6                                          7                       8             9             10                                H7CX-A@                        6                                    7                               8                     9                                     10

H7CX-A11@          3                  7                       5                          6                               4                                                   H7CX-A11@                           3               7                    5          6          4                                             H7CX-A11@                                                3                                          7                       5             6             4                                 H7CX-A11@                      3                                    7                               5                     6                                     4

Note: Operates with transistor ON.                                                                                                                                        Note: Operates with transistor ON.                                                                                                              Note: Operates                                       with                           relay ON.                                                                                             Note: Operates with transistor ON.

No-voltage Input Signal Levels

                                      Short-circuit level (transistor ON)                                                                                                                                                                                                                                                                                                                                                                                                                                           Applicable Two-wire Sensor

                                      • Residual voltage: 3 V max.                                                                                                                                                                                                                                                                                                                                                                                                                                               •  Leakage current: 1.5 mA max.

No-contact input                      • Impedance when ON: 1 kΩ max.                                                                                                                                                                                                                                                                                                                                                                                                                                             •  Switching capacity: 5 mA min.

                                      (The leakage current is approx. 12 mA when the impedance is 0 Ω.)                                                                                                                                                                                                                                                                                                                                                                                                          •  Residual voltage: 3 VDC max.

                                      Open level (transistor OFF)                                                                                                                                                                                                                                                                                                                                                                                                                                                •  Operating voltage: 10 VDC

                                      • Impedance when OFF: 100 kΩ min.

Contact input                         Use contacts which can adequately switch 5 mA at 10 V.

Note: The DC voltage must be 30 VDC max.

Voltage Inputs (PNP Inputs)

No-contact Input (NPN Transistor)                                                                                                                                                                              No-contact Input (PNP                                                                                      Transistor)                                                                                                                 Contact Input

                  Sensor                                                                                                                                                                                                                                         Sensor

                                                              0 V for inputs             Reset/reset 1 input             CP2 input                             CP1 input      Total reset/reset 2 input                                                                                                   0 V for inputs      Reset/reset 1 input     CP2 input     CP1 input      Total reset/reset 2 input                                                                                                                    0 V for inputs     Reset/reset 1 input                  CP2 input                       CP1 input             Total reset/reset 2 input

          H7CX-A@                        6                                    7                               8                     9                                     10                                                     H7CX-A@                                        6                                         7                        8             9             10                                                                                                 H7CX-A@                                    6                  7                       8                          9                               10

          H7CX-A11@                      3                                    7                               5                     6                                     4                                                      H7CX-A11@                                      3                                         7                        5             6             4                                                                                                  H7CX-A11@                                  3                  7                       5                          6                               4

Note: Operates with transistor OFF.                                                                                                                                                                                              Note: Operates with transistor ON.                                                                                                                                                                                                               Note: Operates with relay ON.

Voltage Input Signal Levels

High level (input ON): 4.5 to 30 VDC

Low level (input OFF): 0 to 2 VDC

Note: 1.  The DC voltage must be 30 VDC                                                                                                                                                                  max.

2.        Input resistance: Approx. 4.7 kΩ

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   9
H7CX-A@-N

Nomenclature

                Display Section                                                                       4                     Operation Keys

    1. Key Protect Indicator (orange)                        1                                        7                10. Mode Key

                                                                                                                       (Changes modes and setting items.)

    2. Control Output Indicator (orange)                     2

    OUT: (One-stage)                                                                                  8                11. Reset Key (See note.)

    OUT:  1  2      (Two-stage)                              3

                                                             5                                        6                12. Up Keys     1      to  4

    3. Reset Indicator (orange)                              10                                       12               (6-digit models:              to        )

    (Lit when the reset input (1) or Reset Key is ON.)       11                                                                                   1         6

                                                                                                      13

    Displayed only when the configuration selection                                                                    13. Down Keys          1   to 4

    mode is not tachometer mode.

                                                                      4th digit       1st digit

    4. Total Count Indicator                                          (Front view of  4-digit model)

    (Lit when the total count value is displayed.)                                                                                            Switches

    5. Batch Indicator                                                                                                 14. Key-protect Switch

    (Lit when the batch count value is displayed.)

                                                                                                      7                (Default setting) OFF         ON

    6. Set Value 1, 2 Stage Indicator                                                                 4                     (Disable)                (Enable)

    7. Present Value (Main Display)                          1                                        5

                                                             2                                        8

    (Character height: 12 mm (6-digit: 10 mm), red*)         3           RST

    * Characters on models with screw terminals (H7CX-A11@)  9                                        6

    can be switched between red, green, and orange.          10

                                                             11                                       12               15. DIP Switch

    8. Set value (Sub-display)

    (Character height: 6 mm, green)                                                                                    ON

    9. Hold Display (orange)                                          6th digit       1st digit

    Displayed only when the configuration selection                   (Front view of  6-digit model)                   OFF          1  2      3   4  5   6     7  8

    mode is not tachometer mode.

                                                                                      Note: The reset     functions depends on the selected configuration.

    Model with 4 Digits                                                               Configuration                         Reset operation

    Character Size    Character Size                                                  1-stage/2-stage

    for Main Display  for Sub-display                14                       15                          Resets the present value and outputs.

                                                                                      preset counter

                                                                                      Total and preset    • Resets the present value and outputs.

          12 mm                  6 mm                                                 counter             • When the total count value is displayed, resets the

                                                                                                          present value, the total count value, and outputs.

                                                                                                          • Resets the present value and OUT2.

                                                                                      Batch counter       • When the batch count value is displayed, resets the

    Model with 6 Digits                                                                                   present value, the batch count value, and outputs.

    Character Size    Character Size                                                  Dual counter        Resets the CP1 present value, CP2 present value, dual

    for Main Display  for Sub-display                                                                     count value, and outputs.

                                                                                                          Resets the CP1 present value and output 1 when the

          10 mm                  6 mm                                                 Twin counter        CP1 present value is displayed.

                                                                                                          Resets the CP2 present value and output 2 when the

                                                                                                          CP2 present value is displayed.

                                                                                                          Holds the measurement value and outputs (hold

                                                                                                          function).

                                                                                                          (When the input mode is 2-input independent

                                                                                      Tachometer          measurement, the CP1 measurement value display will

                                                                                                          hold the CP1 measurement value and output 1 and the

                                                                                                          CP2 measurement value display will hold the CP2

                                                                                                          measurement value and output 2.)

Dimensions                                                                                                                                                        (Unit: mm)

Counters

H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/-AWSD1-N/-A4-N/-A4S-N/-A4W-N/-AU-N/-AUD1-N/-AUSD1-N

(Flush Mounting Models)                                      48 × 48  6               78

                                                                                                          44.8 × 44.8

                                                                                      Note: M3.5 terminal screw (effective length: 6 mm)

10
                                                                                                                                 H7CX-A@-N

H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N (Flush Mounting Models)

                        48 × 48                        6           59

                                                                                   44.8 × 44.8

                                                                   Note: M3.5 terminal screw (effective length: 6             mm)

H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N (Flush Mounting/Surface                                         Mounting Models)

                        48 × 48                        6           63.7            14.4

                                                                                         44.8 × 44.8

Dimensions with Flush Mounting Adapter

H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/-AWSD1-N/-A4-N/-A4S-N/-A4W-N                                           Panel Cutouts

(Provided with Adapter and Waterproof Packing)                                                             Panel cutouts are as shown below. (according

                                                                                                           to DIN43700).

    Y92S-29 (provided)                          Panel  Y92F-30 (provided)                                                                      60 min.

    Waterproof Packing                                 Flush Mounting Adapter                                                      45+00.6

                                                                                                                      45+00.6

58      (51)                                                                                                          15 min.

                                                                                                                  60 min.

                                                                                                           Note:  1.  The mounting panel thickness

    48                  7.5                               76.5                                                        should be 1 to 5 mm.

                                                                                                                  2.  To allow easier operation, it is

H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N                                                                      recommended that Adapters be mounted

                                                                                                                      so that the gap between sides with hooks

(Provided with Adapter and Waterproof Packing)                                                                        is at least 15 mm (i.e., with the panel

                                                                                                                      cutouts separated by at least 60 mm).

    Y92S-29 (provided)                          Panel  Y92F-30 (provided)                                         3.  It is possible to horizontally mount

    Waterproof Packing                                 Flush Mounting Adapter                                         Timers side by side. Attach the Flush

                                                                                                                      Mounting Adapters so that the surfaces

                                                                                                                      without hooks are on the sides of the

                                                                                                                      Timers. If they are mounted side-by-

                                                                                                                      side, water-resistance will be lost.

58      (51)                                                                                                               n Units mounted

                                                                                                                                 side by side

                                                                                                                                   A

                                                                                                                              A=(48n−2.5)      +1

                                                                                                                                               −0

    48                  7.5                            57.5                                                           With Y92A-48F1 attached.

                                                                                                                      A={48n−2.5+(n−1)×4}               +1
                                                                                                                                                        −0

H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N                                                      With Y92A-48 attached.

                                                                                                                      A=(51n−5.5)     +1
                                                                                                                                      −0
(Adapter and Waterproof Packing Ordered Separately)

    Y92S-29 (order separately)                  Panel  Y92F-30 (order separately)                          Dimensions with Front

    Waterproof Packing                                 Flush Mounting Adapter

                                                                               P3GA-11 (order separately)  Connecting Socket

                                                                               Back-connecting Socket

58                      (51)                                                                                                       H7CX

                                                                                                                      103.2*       -A11@                100.9

    48                  7.5                                  89.9

                                                                                                                      P2CF-11(-E) Front Connecting Socket

                                                                                                                                 (order separately)

                                                                                                           *  These dimensions depend on the kind of DIN Track.

                                                                                                              (Reference value)

                                                                                                                                                                 11
H7CX-A@-N

Accessories (Order Separately)                                          Soft Cover                        Hard Cover

    Note:  Depending on the operating environment, the condition        Y92A-48F1                         Y92A-48

           of resin products may deteriorate, and may shrink or

           become harder. Therefore, it is recommended that resin

           products are replaced regularly.

Front Panel (Replacement Part)

You can change the color of the Front Panel when mounting the           Protecting the Counter/Tachometer in Environments

Counter/Tachometer. The Counter/Tachometer is shipped with a            Subject to Oil

black (N1.5) Front Panel. "COUNTER" is printed on the front of

Replacement Front Panels.                                               The H7CX's panel surface is water-resistive (conforming to IP@6,

Y92P-CXC4G                                                              UL Type 4X) and so even if drops of water penetrate the gaps

4-digit Counter                                                         between the keys, there will be no adverse effect on internal circuits.

Light gray (5Y7/1)                                                      If, however, there is a possibility of oil being present on the

Y92P-CXC4S                                                              operator's hands, use the Soft Cover. The Soft Cover ensures

4-digit Counter                                                         protection equivalent to IP54F against oil. Do not, however, use the

White (5Y9.2/0.5)                                                       H7CX in locations where it would come in direct contact with oil.

Y92P-CXT4B                                                              Flush Mounting           Adapter

4-digit Counter                                                         Y92F-30                  Y92F-45

Black (N1.5)

                                                                        Order the Flush          Use this Adapter to

Y92P-CXT6G                                                              Mounting Adapter with    install the Counter/

6-digit Counter                                                         the following model      Tachometer in a

Light gray (5Y7/1)                                                      number separately if it  cutout previously

                                                                        is lost or damaged.      made for a DIN 72

Y92P-CXT6S                                                              Note:  The               × 72 mm device

                                                                               Waterproof        (panel cutout: 68 ×

6-digit Counter                                                                Packing is        68 mm).

White (5Y9.2/0.5)                                                              included with

                                                                               models with

Y92P-CXT6B                                                                     screw

6-digit Counter                                                                terminals.

Black (N1.5)                                                            Waterproof Packing

Replacement Method                                                      Y92S-29                           Order the Waterproof Packing

                                                                        Note:  The                        separately if it is lost or damaged. The

                                    The Front Panel is attached to the         Waterproof                 Waterproof Packing can be used to

                                    Counter/Tachometer with tabs in            Packing is                 achieve IP66 protection.

                                    four locations. To remove the              included with

                                                                               models with

                                    Front Panel, open the tabs and             screw

                                    pull the Front Panel forward. To           terminals.

                                    attach the Front Panel, press it    The Waterproof Packing will deteriorate, harden, and shrink

                                    onto the Counter/Tachometer so      depending on the application environment. To ensure maintaining the

    Tabs                            that all four tabs lodge into the   IP@6, UL Type 4X waterproof level, periodically replace the

                                    grooves on the body of the          Waterproof Packing. The periodic replacement period will depend on

                           Grooves  Counter/Tachometer.                 the application environment. You must confirm the proper

                                                                        replacement period. Use 1 year or less as a guideline. If the

                                                                        Waterproof Packing is not replaced periodically, the waterproof level

                                                                        will not be maintained. It is not necessary to mount the Waterproof

                                                                        Packing if waterproof construction is not required.

12
                                                                                                                                                                      H7CX-A@-N

Connection Sockets

Front Connecting Socket

Model                                                                     Dimensions                                                       Terminal arrangement       Mounting hole

                                                                                                                                           and internal connections   dimensions

P2CF-11                                                                   50 max.                                       31.2 max.

                             Two, 4.5-dia. holes

                                                                                                      70 max.

                                                                                                   4                                       8      7         6      5

                                                                                                                                                                   4  Two, M4 or 4.5-dia. holes

                         Eleven, M3.5 × 7.5 sems screws                                       7.8                 3                     4

P2CF-11-E                                                      50 max.                                               31.2 max.                                        40±0.2

(Finger-safe Type)                                                 40±0.2                                               30                                            Note: The Socket can

                                                                                                                                           9                       3

                                                    8      7                6         5                                                    10     11        1      2  also be mounted

                         Two, 4.5-dia. holes                                                               3                                  (Top       View)        to DIN track.

                                                               P2CF-11-E

                                                                                   4

                                                                                                 70  max.  1.2                     35.4

                                                        9                          3

                                                               10A250VAC

                                                               RESISTIVE

                                                    10     11               1         2       4

                         Eleven, M3.5 × 7.5 set screws                                   7.8                   5                   4.5

Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals.

Back-connecting Sockets

Model                                                                     Dimensions                                                       Terminal arrangement

                                                                                                                                           and internal connections

P3GA-11                                                    27 dia.

                                                                                                                                                  5   6  7     8

                                                                                                                                               4

                             45                                                                                   25.6

                                                                                                                                               3               9

                                                                                                                                                  2   1  11    10

                                                               45                        4.5                    6.2                        (Bottom View)

                                                                                                     16.3

Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction.

Terminal Covers for P3GA-11 Back-connecting Socket

Model                                                                     Dimensions

Y92A-48G                     Twelve, 6.4-dia. holes

                         34  Y92A-48G  UP                      47.7 × 47.7                       48 × 48

                                              P  C

                                                                   16.5    24.6

                                                                                   27.6

                             47.4

Note: The Terminal Cover can be used with a Back-mounting Socket (P3GA-11) to create a finger-safe construction.

                                                                                                                                                                                                 13
H7CX-A@-N

Optional Products  for  Track Mounting

Mounting Track

PFP-100N                                                                                                                      7.3±0.15

PFP-50N                                   4.5

                                                                                                                              35±0.3        27±0.15

                                               15      25  10  25                   25    10      25             15 (5)*                    1

                                                                      1,000 (500)*                         *  The values shown in       parentheses

                                                                                                              are for the PFP-50N.

Mounting Track                                                                                                                          16

PFP-100N2                                 4.5

                                                                                                                 35±0.3   27  24               29.2

                                               15      25  10  25                   25    10  25       15                         1            1.5

                                                                      1,000

End Plate                                                                                 10

PFP-M                                                                                             6.2      1.8

                                                   M4 × 8

                                                   pan head

                                                   screw                                          1

                                                   50                                                      35.5  35.3

                                                                                                      1.8

                                                   11.5

                                                               10                                 1.3

                                                                      M4 spring  washer           4.8

    Spacer                                                                                    16

                                                                   5                          12

    PFP-S

                                                                                    44.3                   34.8

                                                                                              16.5

Note: Order Spacers in increments of 10.

14
                                                                                                                                                                     H7CX-A@-N

Operating Procedures                                                                                                                                                         Counter

Setting Procedure Guide

Setting for Counter Operation *

Use the following settings.

Setting for Tachometer Operation *

Refer to page page 27.

*  At the time of delivery, the H7CX is set to the 1-stage preset counter configuration. (2-stage models are set to the 2-stage preset counter configuration.) Refer to page page 35 for information

   on switching models.

I/O Functions for Counter Operation

   Step1                 Set the basic parameters.

                         (If the desired I/O mode is not listed below or to set all parameters using the front panel keys, perform                                      Step3   ,

                         below.)

                                  Key-protect switch

                                                                                          Be sure to set pin 1 to ON.

                                                                           ON

                                                                           OFF      1     2  3    4  5  6  7  8

                         Item                             OFF              ON

   1      DIP switch settings                             Disabled         Enabled

   2      Counting speed                                  30 Hz            5 kHz                                     Pin 4                      Pin 5              Output mode

   3      Input mode                                      UP               DOWN                                      OFF                        OFF                     N

   4      Output mode                         Refer to the          table  on the right.                             ON                         OFF                     F

   5                                                                                                                 OFF                        ON                      C

   6      Output time                                     0.5 s            0.05 s                                    ON                         ON                      K-1

   7      Minimum reset signal                            20 ms            1 ms

   8      Input selection                                 NPN              PNP

   Note: All pins are factory-set to OFF.

   • When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON.

   • DIP switch settings are effective when the power is turned ON again. (Perform DIP switch                                         settings         while  the  power is OFF.)

   Step2                 The H7CX-A@-N is a Counter that contains more than one functional counter.

                         When using the Counter in any mode other than the default mode*, use the following chart to enter

                         Configuration Selection Mode and set the functions that are suitable to the application.

                         * The default mode is 1-stage preset counter configuration (2-stage preset counter configuration for 2-stage models).

                         Note:  Step2  can be performed first, followed by          Step1         .

          Power ON                                        Configuration

                                                          selection mode

                                        +  1

                                  Hold down for 1 s min.

      Run mode                                                                     Select the function from Table 1 using the U (D) Key.

                                        +  1                                                                                                                  twn

                                  Hold down for 1 s min.

                                                                                          (1-stage         (2-stage  (Total and       (Batch    (Dual         (Twin     (Tachometer)

                                                                                          preset           preset    preset counter)  counter)  counter)      counter)

                                                                                          counter)         counter)

                                                                                    Note: The configuration that can be selected depends on the model.

   After making DIP switch settings for basic operations, advanced functions can be added using the operation keys.

   For details, refer to page page 16.

                                                                                                                                                                                                      15
H7CX-A@-N

Counter

    Step3                          Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel.

    Change to Function Setting Mode.

                               Power ON

                                                      3 s min.*1                  For details on operations and display in run mode, refer to page page 20.

                                                              Function            The display depends on the selected configuration.

                               Run mode                      setting mode

                                                      3 s min.*2

                           *1  If the mode is switched to the function setting mode during operation, operation will continue.

                           *2  Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also,

                               when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode.

                                                                                                                                                                                            *3 When Using Dual Counter

                                                                  The characters displayed in reverse video are the default settings.                                                             Operation

                                                                  When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).                                                    Dual count

                                                                  If pin 1 of the DIP switch is set to ON, the setting items indicated by     will not be displayed.                                                         calculating

                                                                  For 6-digit models, only U Keys are provided.                                                                                                              mode

                                                         *3       Displays for 6-digit models are given in parentheses.                                                                                                      (ADD)

                                                                                                                                                                                                  • Set the dual count calculating

                                               Input mode         • Set the input mode using the U (D) Keys.                                                                                      mode using the UD Keys.

                                               (CNTM)                   *5        *5                                                                                                                                         *4

                                                                  up             down      ud-a            ud-b            ud-c                                                                       add              sub

                                                                  (UP)           (DOWN)    (UP/DOWN A) (UP/DOWN B)    (UP/DOWN C)                                                                     (Addition) (Subtraction)

                                                                  Note: Displayed only when Twin Counter Mode is not selected.                                                                    *4 Displayed only when the output mode is K-2,

                                                                                                                                                                                                    D, L, or H.

                                                                  *5 Displayed for output modes other than K-2, D, L, and H only.                                                           Usage as a Decrementing Counter (5ub)

                                               Output mode        • Set the output mode using the U (D) Keys.                                                                               The 5ub parameter is normally not

                                               (OUTM)                                                                                                                                       displayed. You must set the outm

                                                                            f     c        r        k-1          p         q     a            *6   *6                   *6  *6              parameter shown below in advance to *6
                                                                  n                                                                        k-2     d        l               h
                                                                                                                                                                                            (k-2, d, l, or h) to display it.
                                                                  (N)       (F)   (C)      (R)      (K-1)        (P)  (Q)        (A)       (K-2)   (D)  (L)                 (H)

                                                         *7       *6 Displayed only when the input mode is ud-a, ud-b, or ud-c.                    *7 Set each digit using the individual U (D) Keys.

                                                                  (Not displayed when the function is set to twn.)

                                                                                                                                                      When using as a 2-stage preset counter

                                               Output             • Set each digit using the individual U (D) Keys.                                                              One-shot

                                               time                                                                                                                              output 2                        0.01      0.50    99.99

                                               (OTIM)                                                                                                                            time                 (0.01 s) (0.50 s) (99.99 s)

                                                                  0.01      0.50      99.99                                                                                      (OTM2)               Note: Displayed only when the

                                                                  (0.01 s) (0.50 s) (99.99 s)                                                                                                                    output mode is C, R, K-1,        P, Q,

                                                                  Note: Displayed only when the output mode is C, R, K-1, P, Q, A,                                                                               A, or K-2.

                                                                        or K-2.                                                                                                  One-shot

                                                                                                                                                                                 output 1                        hold 0.01          99.99

                                               Counting           • Set the counting speed using the U (D) Keys.                                                                 time                 (Outputs held) (0.01 s)      (99.99 s)

                                                                                                                                                                                 (OTM1)               If the output time is 0.00, hold is displayed.

    Function Setting Mode                      speed                                                                                                                                                  Note: Displayed for output modes

                                               (CNTS)             30hz                                                                                                                                           other than D, L, and H.

                                                                  (30 Hz)        (5 kHz)                                                                                                                         HOLD cannot be set when

                                                                                                                                                                                                                 the output mode is K-2.

                                                                                                                                                      When using as a batch counter

                                                                                                                                                                                            One-shot             0.01      0.50     99.99

                                                                  • Set the Reset input signal width using the U (D) Keys.                                                                  output 2

                                               Reset input                                                                                                                                  time                 (0.01 s) (0.50 s) (99.99 s)

                                               signal width                                                                                                                                 (OTM2)    Note: Displayed only when the

                                               (IFLT)             20ms           1ms                                                                                                                             output mode is C, R, K-1, P, Q,

                                                                  (20 ms)        (1 ms)                                                                                                                          A, or K-2.

                                               Decimal            • Set the decimal point position using the U (D) Keys.

                                               point position

                                               (DP)

                                                                  (No decimal point)           (One digit after            (Two digits after            (Three digits after

                                                                                                decimal point)             decimal point)               decimal point)

                                                                                                                                                   *7 Set each digit             using the            individual U (D) Keys.

                                               Prescale           • Set each digit using the individual U (D) Keys.                                Twin Counter

                                               value              0.001          1.000         9.999    99.999                                                                   Output 2                        0.01  0.50      99.99

                                               (PSCL)             (0.001)        (1.000)                (99.999)                                                                 output

                                                                                               (9.999)                                                                           time                 (0.01 s) (0.50 s) (99.99 s)

                                                                                                                                                                                 (OTM2)               Note:      Displayed only when the

                                                                                                                                                                                                                 output mode is C, R, K-1,        P,

                                                                                                                                                                                                                 Q, or A.

                                               NPN/PNP            • Set the NPN/PNP input mode using the U (D) Keys.

                                               input mode                                                                                                                        Output 1                        0.01  0.50      99.99

                                               (IMOD)             npn            pnp                                                                                             output               (0.01 s) (0.50 s) (99.99 s)

                                                                                                                                                                                 time

                                                                  (NPN input) (PNP input)                                                                                        (OTM1)               Note:      Displayed only when the

                                                                                                                                                                                                                 output mode is C, R, K-1, P,

                                                                                                                                                                                                                 Q, or A.

                                               Display color      • Set the display color using the U (D) Keys.

                                               (COLR)             red            grn       org          r-g           g-r     r-o             o-r     g-o                   o-g

                                                                  (Red)          (Green)  (Orange)  (Red-green)  (Green-red)  (Red-orange) (Orange-red) (Green-orange)      (Orange-green)

                                                                  Note: Displayed for terminal-block models (except H7CX-A11@) only.

    From next page             To  next  page

16
                                                                                                                                                                               H7CX-A@-N

                                                                                                                                                                                                      Counter

To previous                  From previous

                       page  page

                                            Absolute value    • Make the absolute value setting and forecast setting using the U (D) Keys.

                                            setting/forecast

                                            value setting

                                            (SETM)            abs     ofst

                                                              (ABS)   (OFST)

                                                              Note: Displayed only when the configuration selection mode is set to the 2-stage function 2cnt.

                                            Set value         • Set each digit using the individual    U (D) Keys.

                                            upper limit

                                            (SL-H)            1       9999

                                                              (1)     (9999)

                                                              Note: 1 to 999999 for 6-digit models

                                            Forecast          • Set each digit using the individual    U (D) Keys.

                                            setting

Function Setting Mode                       upper limit       1       9999

                                            (PL-H)            (1)     (9999)

                                                              Note: 1 to 999999 for 6-digit models.

                                                              Note: Displayed only when the configuration selection mode  is  set    to  the  2-stage     function  2cnt  and  a  forecast            value   is  set.

                                            Batch count       • Set each digit using the individual    U (D) Keys.

                                            upper limit

                                            (BL-H)            1       9999

                                                              (1)     (9999)

                                                              Note: 1 to 999999 for 6-digit models.

                                                              Note: Displayed only when the output mode is set to bcnt.

                                            Output

                                            allocation        off     on

                                            change            (OFF)   (ON)

                                                              Note: Displayed only for "-AU@" models.

                                                              off: Output 1 = 12, 13, Output 2 = 3, 4, 5     on: Output 1 = 3, 4, 5, Output 2 = 12, 13

                                                              The numbers are the terminals numbers.

                                            Key protect                                                U (D) Keys.

                                            level             • Set the key protect level using the

                                            (KYPT)

                                                              kp-1    kp-2    kp-3                   kp-4    kp-5         kp-6               kp-7

                                                              (KP-1)  (KP-2)  (KP-3)                 (KP-4)  (KP-5)       (KP-6)             (KP-7)

                                            *8

                                            Output ON

                                            count alarm set

                                            value/monitor                                            *8 Set each digit using the individual   U (D) Keys.

                                            value

                                                                                                     Procedure for Models Other than “-@W@” Models

                                                                                                                          Output

                                                                                                                          ON count                              0   9999

                                                                                                                          alarm set                  (0 × 1000 times) (9999 × 1000 times)

                                                                                                                          value

                                                                                                                          Output

                                                                                                                          ON count

                                                                                                                          monitor            Note:  The monitor value is only displayed. It cannot be set.

                                                                                                                          value

                                                                                                     Procedure  for  “-@W@” Models

                                                                                                                          Output 1

                                                                                                                          (OUT1) ON                             0   9999

                                                                                                                          count alarm

                                                                                                                          set value                  (0 × 1000 times) (9999 × 1000 times)

                                                                                                                          Output 2

                                                                                                                          (OUT2) ON                             0   9999

                                                                                                                          count alarm

                                                                                                                          set value                 (0 ×  1000  times) (9999 × 1000 times)

                                                                                                                          Output 1

                                                                                                                          (OUT1) ON

                                                                                                                          count monitor

                                                                                                                          value               Note:       The   monitor value is only displayed.  It  cannot  be  set.

                                                                                                                          Output 2

                                                                                                                          (OUT2) ON

                                                                                                                          count monitor

                                                                                                                          value               Note:       The   monitor value is only displayed.  It  cannot  be  set.

                                                                                                                                                                                                                        17
H7CX-A@-N

Counter

Explanation of Functions

Items marked with stars ★ can be set using the DIP switch.

Input Mode (cntm)★                                                         Prescale Value (pscl)

Set increment mode (UP), decrement mode (DOWN), or one of the              Pulses input to the counter are converted according to the specified

increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/                    prescale value.

DOWN C) as the input mode.                                                 (Setting range: 0.001 to 99.999 for 6-digit models and 0.001 to 9.999

Input modes other than UP or DOWN modes cannot be set using the            for 4-digit models.)

DIP switch and so use the operation keys if other modes are required.      Example: To display the feed distance for systems that output 25

(For details on the operation of the input modes, refer to Input Modes     pulses for a feed length of 0.5 m in the form @@.@@ m:

and Present Value on page page 21.)                                        1. Set the decimal point position to 2 decimal places.

Dual Count Calculating Mode ( calm)                                        2. Set the prescale value to 0.02 (0.5 ÷ 25).

When using as a dual counter, select either ADD (addition) or SUB                0.5 m

(subtraction) as the calculation method for the dual count value.

ADD: Dual count value = CP1 PV + CP2 PV

SUB: Dual count value = CP1 PV − CP2 PV

Output Mode (outm)★

Set the way that control output for the present value is output. The

possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.                                                           25 pulses

Output modes other than N, F, C, or K-1 cannot be set using the DIP

switch and so use the operation keys if other modes are required. The                                          Encoder

output modes that can be set vary with the model.

(For details on the operation of the output modes, refer to Input/            •  Observe the following points when setting a prescale value.

Output Mode Settings on page page 22.)                                           Set the set value to a value less than {Maximum countable value

One-shot Output Time (otim)★                                                     − Prescale value}.

Set the one-shot output time (0.01 to 99.99 s) for control output.               Example: If the prescale value is 1.25 and the counting range is

One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is              0.000 to 999.999, set the set value to a value less than 998.749

selected as the output mode. Output times other than 0.5 s or 0.05 s             (= 999.999 − 1.25).

cannot be set with the DIP switch and so use the operation keys if               If the set value is set to a value greater than this, output will not turn

other settings are required.                                                     ON.

                                                                              •  Output will turn ON, however, if a present value overflow occurs

One-shot Output 2 Time (otm2)★                                                   (FFFFFF or FFFF).

Set the one-shot output time (0.01 to 99.99 s) for control output             Note: If the prescale value setting is incorrect, a counting error will

(OUT2).                                                                               occur. Check that the settings are correct before using this

One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is                   function.

selected as the output mode. Output times other than 0.5 s or 0.05 s

cannot be set with the DIP switch and so use the operation keys if         NPN/PNP Input Mode (imod)

other settings are required.                                               Select either NPN input (no-voltage input) or PNP input (voltage

One-shot Output 1 Time (otm1)                                              input) as the input format. When using a two-wire sensor, select NPN

Set the one-shot output time (0.01 to 99.99 s) for control output          input.

(OUT1).                                                                    The same setting is used for all external inputs.

One-shot output can be used only when D, L, or H is selected as the        For details on input connections, refer to Input Connections on page

output mode.                                                               page 9.

If the output time is set to 0.00, hold is displayed, and outputs are      Display Color (colr) (Displayed for terminal block models

held.                                                                      (except H7CX-A11@) only.)

Counting Speed (cnts)★                                                     Set the color used for the present value.

Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2                                                   Output OFF*                  Output ON*

inputs together.                                                                      red                                   Red (fixed)

If contacts are used for input signals, set the counting speed to 30 Hz.

Processing to eliminate chattering is performed for this setting.                     grn                                   Green (fixed)

Reset Input Signal Width (iflt)★                                                      org                                   Orange (fixed)

Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total             r-g                      Red                          Green

reset/reset 2 inputs together.                                                        g-r                      Green                        Red

If contacts are used for the input signal, set the input signal width to

20 ms. Processing to eliminate chattering is performed for this setting.              r-o                      Red                          Orange

Decimal Point Position (dp)                                                           o-r                      Orange                       Red

Decide the decimal point position for the present value, CP1/CP2                      g-o                      Green                        Orange

present values, set value (SV1, SV2), total count value, and dual                     o-g                      Orange                       Green

count set value.                                                           *     Output 2 for 2-stage models.

                                                                           With the twin counter, output 1 and output 2 will both turn OFF when

                                                                           the output status is OFF. Either output 1 or output 2 will turn ON when

                                                                           the output status is ON.

18
                                                                                                                                        H7CX-A@-N

                                                                                                                                                  Counter

Absolute Value Setting/Forecast Value Setting (setm)                                      Output ON Count Alarm Set Value (on-a)

For the 2 count output mode, an absolute value setting (abs) or                           Set the alarm value for the output ON count.

forecast value setting (ofst) can be set for set value 1.                                 The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000

When a forecast value is set, specify the forecast value set value (i.e.,                 (9,999,000 times). Only the underlined values are set. The alarm will

the deviation for the set value).                                                         be disabled if 0 is set.

The forecast output (output 1) turns ON when the present value                            If the total ON count of the output exceeds the alarm set value,     e3

reaches the forecast value.                                                               will be displayed on the Timer to indicate that the output ON count

If the forecast set value is greater than or equal to the set value, the                  alarm value was exceeded. Refer to Self-diagnostic Function on page

forecast output (output 1) will turn ON as soon as counting starts.                       page 36 for information on the e3 display.

                                     Example: F Mode            Count value               ON Count Alarm Set Values for Outputs 1 and 2 (OUT1

                        Set value 2                                                       and OUT2) (on1a and on2a)

                                                                                          Set the ON count alarm values for the outputs 1 and 2.

                        Set value 1                                                       The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000

                                  0                                                       (9,999,000 times). Only the underlined values are set. The alarm will

                                                                                          be disabled if 0 is set.

         Control output 1 (OUT1)                                                          If the total ON count of instantaneous output 1 or 2 exceeds the alarm

                                                                                          set value, e3 will be displayed on the Timer to indicate that the output

         Control output 2 (OUT2)                                                          ON count alarm value was exceeded. Refer to Self-diagnostic

If the forecast value setting is used, specify        the  set  value 2 minus        the  Function on page page 36 for information on the e3 display.

forecast value setting for set value 1.                                                   Output ON Count Monitor Value (on-c)

                                     Example: F Mode            Count value               The monitor value is only displayed. It cannot be set.

                        Set value                                                         The output ON count will be 1,000 times the displayed value.

    Forecast set value

                        Forecast                                                          ON Count Monitor Values for Outputs 1 and 2 (OUT1 and

                        value                                                             OUT2) (on1c and on2c)

                                 0                                                        The monitor value for output 1 or 2 is only displayed. It cannot be set.

         Forecast output (OUT1)                                                           The output ON count will be 1,000 times the displayed value.

         Control output (OUT 2)

Set Value Upper Limit (sl-h)

Set the upper limit for the set value when it is set in run mode.

The setting can be made from 1 to 9999 for 4-digit models and from

1 to 999999 for 6-digit models.

Forecast Set Upper Limit (pl-h)

Set the upper limit for the forecast set value.

The setting can be made from 1 to 9999 for 4-digit models and from

1 to 999999 for 6-digit models.

Batch Count Upper Limit (bl-h)

Set the upper limit for the batch count value. The setting can be made

from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit

models.

Output Allocation (otst)

When using an H7CX-AU@-N model as a 2-stage counter, the output

can be flexibly allocated to either stage 1 or 2.

The transistor output can be allocated to SV1 and the contact output

to SV2 or vice verse, as in the following tables.

H7CX-AU-N/-AUD1-N

                        Output 1                           Output 2

off      Transistor (12-13)               Contact (3, 4, 5)

on       Contact (3, 4, 5)                Transistor (12-13)

H7CX-AUSD1-N

                        Output 1                           Output 2

off      Transistor (12-13)               Transistor       with diode  (3,   4,  5)

on       Transistor with diode (3, 4, 5)  Transistor       (12-13)

Key Protect Level (kypt)

Set the key protect level.

Refer to Key Protect Level on page        page 36.

                                                                                                                                                                    19
H7CX-A@-N

Counter

Operation in Run Mode

I/O Functions for Counter Operation

    • Set values for each digit as required using the U (D) Keys. (U Key only for 6-digit models.)

    1-stage Preset Counter                                    Total  and  Preset  Counter                               Dual Counter

                                       Present value

                                       Set value                                                 Present value                                            Dual count value

                                                                                                 Set value                                                Dual count

    2-stage Preset Counter  with                                                                                                                          set value

    Absolute Value Setting

                                                                                                 Total count value                                        CP1 present value

                                       Present value                                                                                                      CP2 present value

                                       Set value 1

                                                                 •  Present Value/Set Value                             •  Dual Count Value

                                                                    Same as 1-stage preset counter.                        Shows the sum of the CP1 present value and

                                       Present value                                                                       CP2 present value when the dual count

                                                                 •  Total Count Value                                      calculating mode is ADD and shows the value

                                       Set value 2                  Shows the present total count value.                   obtained by subtracting the CP2 present

                                                                                                                           value from the CP1 present value when the

                                                                                                                           dual count calculating mode is SUB.

    •  Present Value                                                                                                    •  Dual Count Set Value

       Shows the present count value.                                                                                      Set the dual count set value.

    •  Set Values (Set Value 1 and Set Value 2)               Batch Counter                                                When the dual count value reaches the dual

       Set the set values.                                                                                                 count set value, signals are output according

       When the present value reaches the set value (set                                                                   to the specified output mode.

       value 1 or set value 2), a signal is output according                                                            •  CP1/CP2 Present Value

       to the specified output mode.                                                             Present value             Show the present count values for CP1 and

                                                                                                 Set value                 CP2 present values respectively.

    2-stage Preset Counter with

    Forecast Value Setting

                                                                                                 Batch count value      Twin Counter

                                       Present value                                             Batch count set value

                                       Set value                                                                                                          Present value 1

                                                              •     Present Value/Set Value

                                                                 Same as 1-stage preset counter.                                                          Set value 1

                                                              •     Batch Count Value

                                       Present value             Shows the number of times the count has been

                                       Forecast Set Value           completed for the present value.

                                                              •     Batch Count Set Value                                                                 Present value 2

                                                                 Set the batch count set value.                                                           Set value 2

    •  Present Value                                             When the batch count value reaches the batch

       Shows the present count value.                               count set value, batch output (OUT1) turns ON.

    •  Set Values                                                                                                       •  Present Values 1 and 2

       Set the set values.                                                                                                 Shows the present count value 1 or 2.

    •  Forecast Set Value                                                                                               •  Set Values 1 and 2

       Set the deviation for the set value.                                                                                Setting for present value 1 or 2.

20
                                                                                                                                                                         H7CX-A@-N

                                                                                                                                                                                   Counter

Input Modes and Present Value                                             (See           note     1.)

I/O Functions for Counter Operation

                                    UP (Increment) Mode                                                                            DOWN (Decrement)           Mode

CP1: Count input; CP2: Prohibit (gate) input                                                      CP1:  Count input;      CP2:  Prohibit (gate) input

                  H                                                                                                    H

   CP1                                                                                                      CP1

                  L                                                                                                    L

                                                      A                         A                                                                        A                  A

                                                         Prohibit                                                                                             Prohibit

                  H                                                                                                    H

   CP2                                                                                                      CP2

                  L                                                                                                    L

                                                                                                                          n

                                                                                            5                                   n−1

                                                                                   4                                                      n−2

   Present value                                         3                                              Present value                                         n−3

                                       2                                                                                                                                           n−4

                              1                                                                                                                                                              n−5

                  0  0                                                                                                 0

A  must be greater than the minimum signal width.            (See  note      2.)                  A    must be greater than the minimum signal width.              (See  note 2.)

CP1: Prohibit (gate) input; CP2: Count input                                                      CP1: Prohibit (gate) input; CP2: Count input

         H                                                                                                           H

   *CP1                                                                                                     *CP1

         L                                                                                                           L

                                                A                         A                                                                           A                  A

                                                   Prohibit                                                                                              Prohibit

         H                                                                                                           H

   CP2                                                                                                      CP2

         L                                                                                                           L

                                                                                                                             n

                                                                                               5                                     n−1

                                                                                         4                                                               n−2

   Present value                                                             3                          Present value                                                       n−3

                                                   2                                                                                                                                    n−4

                                 1                                                                                                                                                           n−5

         0              0                                                                                            0

A  must be greater than the minimum signal width. (See note 2.)                                   A    must be greater than the minimum signal width. (See               note 2.)

*  Counting starts when the CP1 is turned ON after turning ON the power.

                           UP/DOWN A Command Input Mode                                                                         UP/DOWN      B  Individual Input Mode

                  H                                                                                                    H

   CP1                                                                                                      CP1

                  L                                                                                                    L

                                                      A                         A

                  H                                                                                                    H

   CP2                                                                                                      CP2

                  L                                                                                                    L

                                             3                                              3                                                   3                                            3

   Present value                       2                 2                         2                    Present value                     2              2                         2

                              1                                    1                                                            1                                  1     1

                  0  0                                                                                                 0  0

A  must be greater than the minimum signal width. (See note                  2.)

                        UP/DOWN C Quadrature Input Mode                                           Note: 1.  If the configuration selection is set to dual counter, CP1 and

                  H                                                                                         CP2 input will operate in the same way as the count input

   CP1                                                                                                      (CP1) of UP (increment) mode.

                  L                                                                                     2.  A        must be greater than the minimum signal width and                          B

                           BBBB                                                                             must be at least 1/2 the minimum signal width.

                  H

   CP2                                                                                                      If they are less, a count error of ±1 may occur.

                  L

                                                                                                            Minimum signal width:            16.7 ms (when maximum counting speed = 30 Hz)

                                                3                                           3                                                100 µs (when maximum counting speed = 5 kHz)

   Present value                          2           2                               2                 3.  The meaning of the H and L symbols in the tables is explained

                                    1                              1                                        below.

                           0                                                                            Symbol                       No-voltage input                    Voltage input (PNP

                  0                                                                                     Input method                      (NPN input)                       input)

B                                                                                                           H                             Short-circuit                  4.5 to 30 VDC

   must be at least 1/2 the minimum signal width. (See note 2.)                                                   L                             Open                        0 to 2 VDC

                                                                                                                                                                                                   21
H7CX-A@-N

Counter

Input/Output Mode Settings

I/O Functions for Counter Operation

If a 1-stage model or 2-stage model is incorrectly used as twin counter, the operation for                One-shot output from OUT1

output 2 will be performed. When using a 2-stage model as a 1-stage preset counter,                                                  (The one-shot output time can be

total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF                                                             set in the range 0.01 to 99.99s.)

simultaneously.                                                                             Self-holding  Self-holding  One-shot

                                                                                            output        output        output from OUT2

                                      Input mode                                                                                          Operation after count

                                  UP  DOWN                                                  UP/DOWN A, B, C                                       completion

                       Reset/

                       reset 1

                       999999

                  Set value 2                                                                                                             The outputs and present

             N    Set value 1                                                                                                             value display are held

                       0                                                                                                                  until reset/reset 1 is

                                                                                                                                          input.

                       OUT1

                       OUT2

                       Reset/

                       reset 1

                       999999

                  Set  value 2                                                                                                            The present value

                  Set  value 1                                                                                                            display continues to

             F                                                                                                                            increase/decrease.

                               0                                                                                                          The outputs are held until

                                                                                                                                          reset/reset 1 is input.

                       OUT1

                       OUT2

                                                                                                                                          As soon as the count

                       Reset/                                                                                                             reaches SV, the present

                       reset 1                                                                                                            value display returns to

                       999999                                                                                                             the reset start status.

                                                                                                                                          The present value display

                  Set value 2                                                                                                             does not show the

    Output        Set value 1                                                                                                             present value upon count-

    mode     C                                                                                                                            up.

    setting            0                                                                                                                  The outputs repeat one-

                                                                                                                                          shot operation.

                       OUT1                                                                                                               OUT1 self-holding output

                                                                                                                                          turns OFF after the OUT2

                                                                                                                                          one-shot output time.

                       OUT2                                                                                                               The OUT1 one-shot

                                                                                                                                          output time is

                                                                                                                                          independent of OUT2.

                       Reset/                                                                                                             The present value

                       reset 1                                                                                                            display returns to the

                                                                                                                                          reset start status after

                       999999                                                                                                             the one-shot output time.

                  Set value 2                                                                                                             The outputs repeat one-

                  Set value 1                                                                                                             shot operation.

             R         0                                                                                                                  OUT1 self-holding output

                                                                                                                                          turns OFF after the

                                                                                                                                          OUT2 one-shot output

                       OUT1                                                                                                               time.

                                                                                                                                          The OUT1 one-shot

                                                                                                                                          output time is

                       OUT2                                                                                                               independent of OUT2.

                       Reset/

                       reset 1                                                                                                            The present value

                       999999                                                                                                             display continues to

                  Set value 2                                                                                                             increase/decrease.

                                                                                                                                          OUT1 self-holding output

             K-1  Set value 1                                                                                                             turns OFF after the

                       0                                                                                                                  OUT2 one-shot output

                                                                                                                                          time.

                                                                                                                                          The OUT1 one-shot

                       OUT1                                                                                                               output time is

                                                                                                                                          independent of OUT2.

                       OUT2

22
                                                                                                                                      H7CX-A@-N

                                                                                                                                                 Counter

                                                                                                           One-shot output from OUT1

                                                                                                                                      (The one-shot output time ca

                                                                                                                                      set in the range 0.01 to 99.9

                                                                                             Self-holding  Self-holding  One-shot

                                                                                             output        output        output from OUT2

                                                                   Input mode                                                              Operation after

                             UP                                     DOWN                     UP/DOWN A, B, C                          count completion

                                                                                                                                      The present value

             Reset/                                                                                                                   display does not

             reset 1                                                                                                                  change during the

             999999                                                                                                                   one-shot output time

                                                                                                                                      period, but the actual

             Set value 2                                                                                                              count returns to the

             Set value 1                                                                                                              reset start status.

                                                                                                                                      The output will return

                          0                                                                                                           to one-shot mode.

          P                                                                                                                           The outputs repeat

             OUT1                                                                                                                     one-shot operation.

                                                                                                                                      OUT1 self-holding

                                                                                                                                      output turns OFF after

             OUT2                                                                                                                     the OUT2 one-shot

                                                                                                                                      output time.

                                                                                                                                      The OUT1 one-shot

                                                                                                                                      output time is

                                                                                                                                      independent of OUT2.

                                                                                                                                      The present value

             Reset/                                                                                                                   continues to increase/

             reset 1                                                                                                                  decrease for the one-

             999999                                                                                                                   shot output time, but

             Set value 2                                                                                                              returns to the reset

Output                                                                                                                                start status after the

mode         Set value 1                                                                                                              one-shot output time

setting                   0                                                                                                           has elapsed.

          Q                                                                                                                           The outputs repeat

                                                                                                                                      one-shot operation.

             OUT1                                                                                                                     OUT1 self-holding

                                                                                                                                      output turns OFF after

             OUT2                                                                                                                     the OUT2 one-shot

                                                                                                                                      output time.

                                                                                                                                      The OUT1 one-shot

                                                                                                                                      output time is

                                                                                                                                      independent of OUT2.

             Reset/

             reset 1

             999999                                                                                                                   The present value

             Set value 2                                                                                                              display and OUT1

             Set value 1                                                                                                              self-holding output is

          A  0                                                                                                                        held until reset/reset 1

                                                                                                                                      is input.

                                                                                                                                      OUT1 and OUT2 are

             OUT1                                                                                                                     independent.

             OUT2

Note: 1.  The full scale (FS) for H7CX 4-digit models is 9999.

      2.  When the present value reaches 999999, it returns to 0.

      3.  Counting cannot be performed during reset/reset 1 input.

      4.  If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.

      5.  If there is power failure while output is ON, output will turn ON again when the power supply has recovered.

          For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered.

      6.  Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.

      7.  The setting range is 0 to 999999 (0 to 9999 for 4-digit models).

                                                                                                                                                                     23
H7CX-A@-N

Counter

                                                                                                                                           (The one-shot output time can be

                                                                                                                                           set in the range 0.01 to 99.99s.)

                                                                                                 Self-holding  Instantaneous     One-shot

                                                                                                 output        (equals) output   output

                                      Input mode                                                                                 Operation after count completion

                                      UP/DOWN A, B, C

                   Reset/

                   reset 1

                   999999

                   Set value 2

                   Set value 1                                                                                                The display continues to increase/

              K-2                  0                                                                                          decrease until the overflow or

                                                                                                                              underflow value is reached.

                   −99999                                                                                                     One-shot output only.

                   OUT1

                   OUT2

                   Reset/

                   reset 1

                   999999

                   Set value 2

                   Set value 1                                                                                                The display continues to increase/

                                                                                                                              decrease until the overflow or

              D                 0                                                                                             underflow value is reached.

                   −99999                                                                                                     The outputs are ON while the count is

                                                                                                                              equal.

                   OUT1

                   OUT2

    Output

    mode

    setting

                   Reset/

                   reset 1

                   999999

                   Set value 2                                                                                                The display continues to increase/

                   Set value 1                                                                                                decrease until the overflow or

                                                                                                                              underflow value is reached.

              L                 0                                                                                             OUT1 is held while the present value

                   −99999                                                                                                     is less than or equal to set value 1.

                                                                                                                              OUT2 is held while the present value

                                                                                                                              is greater than or equal to set value 2.

                   OUT1

                   OUT2

                   Reset/

                   reset 1

                   999999                                                                                                     The display continues to increase/

                   Set value 2                                                                                                decrease until the overflow or

                   Set value 1                                                                                                underflow value is reached.

                                                                                                                              OUT1 is held while the present value

              H    0                                                                                                          is greater than or equal to set value 1.

                   −99999                                                                                                     OUT2 is held while the present value

                                                                                                                              is greater than or equal to set value 2.

                                                                                                                              *  H mode is available only when using a

                   OUT1                                                                                                          model as a 2-stage counter.

                   OUT2

Note: 1.      Counting cannot be performed during reset/reset 1 input.

          2.  If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.

          3.  If there is power failure while output is ON, output will turn ON again when the power supply has recovered.

              For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered.

          4.  Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.

          5.  The set value is from −99999 to 999999 (−999 to 9999 for 4-digit models).

24
                                                                                                                                                                      H7CX-A@-N

                                                                                                                                                                                      Counter

Total and Preset Counter Operation

The H7CX has a total counter, separate from the 1-stage preset                                             counter,  for  counting  the  total accumulated value.

                                                                                                                                              •  The total counter continues to count the total

                Reset/reset 1                                                                                                                    accumulated value when the present value is

                                                                                                                                                 reset using reset/reset 1 input (Reset Key).

       Total Reset or Reset 2                                                                                                                 •  The total count value is reset when the total

                Present value                                                                                                                    reset/reset 2 input is turned ON.

                               0                                                                                                                 If the Reset Key is pressed while the total count

                                                                                                                                                 value is displayed, the total count value is reset.

                       999999                                                                                                                    The present value is also reset at this time.

                Total count value                                                                                                             •  The counting range of the total counter is

                                                                                                                                                 −99,999 to 999,999 (−999 to 9,999). The total

                               0                                                                                                                 count value returns to 0 when it reaches the full

                                   Note: The full scale (FS) for H7CX 4-digit models is 9999.

                                                                                                                                                 scale limit.

Batch Counter Operation

The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed.

                                                                                                                                              •  The batch counter continues after count

                                   Reset 1                                                                                                       completion.

                                                                                                                                              •  Batch output is held until batch counter reset is

                                   Reset 2 (batch                                                                                                input.

                                   counter reset)                                                                                             •  When the batch counter reset input is turned

                                   Set value                                                                                                     ON, the batch count value is reset, and batch

                                   Present value                                                                                                 output turns OFF.

                                                  0                                                                                           •  If the Reset Key is pressed while the batch

                                                                                                                                                 count value is displayed, the batch count value

                                   OUT2                                                                                                          is reset and batch output turns OFF. The

                       Batch count set value                                                                                                     present value is also reset at this time.

                                   Sub-display                                                                                                •  The count value can be incremented and

                       Batch count value                     2                                                                                   decremented.

                                   (Main display)         1

                                                  0                                                                                              The batch count is only incremented.

                                                                                                                                              •  The maximum counting speed for batch counter

                                   OUT1                                                                                                          operation is 5 kHz. The batch counter counts

                                   (batch output)    Note: The above is for when the output mode is C.                                           the number of times the count reaches the set

                                                                                                                                                 value.

Note:  1.  The batch count value is held at 0 during batch counter reset input.

       2.  If the batch count set value is 0, batch count will be performed but there will be no batch output.

       3.  The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models).

       4.  Once batch input has been turned ON, it will return to the ON state after power interruptions.

       5.  If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.

       6.  After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value.

Dual Counter Operation

Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for

which output turns ON when the set value matches the added or subtracted result.

(1) Dual Count Calculating Mode = ADD                        (2)  Dual Count Calculating Mode                        = SUB                    •  The operation after count completion for the

       Dual count value = CP1 PV + CP2 PV                         Dual count value = CP1 PV −                        CP2 PV                      dual counter value is determined by the output

                                                                  Reset 1 (CP1 reset)                                                            mode.

Reset 1 (CP1 reset)                                                                                                                           •  The CP1 present value is reset when reset 1

                                                                  Reset 2 (CP2 reset)                                                            input is turned ON.

Reset 2 (CP2 reset)                                                                                                                              The CP2 present value is reset when reset 2

                                                                  Dual count set value

Dual count set  value                                                                                                                            input is turned ON.

                                                                  Dual count value                                                            •  If the Reset Key is pressed while the dual count

Dual count      value                                                                                   0                                        value, CP1 present value, or CP2 present value

                0                                                 CP1 present value                                                              is displayed, all of the present values are reset

CP1 present     value                                                                                                                            and outputs turn OFF. At this time, counting is

                0                                                                                                                                not possible for CP1 or CP2 inputs.

                                                                                                        0

CP2 present     value                                             CP2 present value

                0                                                                                       0

       OUT1, OUT2                                                 OUT1, OUT2

       Note: The above is for when the output mode is N.          Note:                        The above is for when the output mode is K-2.

                                                                                               SUB mode can be used only when K-2, D, L,

                                                                                               or H is selected as the output mode with

                                                                                               6-digit models.

Note:  1.  Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on a CP1 present value of 0.

       2.  Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on a CP2 present value of 0.

       3.  The counting range for the dual count value is −99,999 to 999,999 (0 to 9,999 for 4-digit models).

           The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models).

           If a present value exceeds 999,999 (9,999 for 4-digit models), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting

           will stop.

                                                                                                                                                                                                      25
H7CX-A@-N

Counter

Twin Counter Operation

Two independent counters are built in.

                                             Counter 1                                 Counter 2

    Counter input                                 CP1                                        CP2

    Reset input                                 Reset 1                                Reset 2

                                      Counter 1 display                       Counter 2 display

                                             Counter 1 present value                   Counter 2 present value

    Present value display and

    setting

                                                          Switched with

                                                          the           Key.

                                             Counter 1 set value                       Counter 2 set value

    Reset Key                                Only counters appearing on the display will be reset.

Note: 1.      Only 2-stage models

          2.  Increment mode only for counters 1 and 2.

          3.  The settings for prescaling and the decimal point are used by both counter 1 and 2.

Reset Function List

I/O Functions for Counter Operation

                    1-stage/2-

    Function        stage preset      Total and preset counter                Batch counter                     Dual counter                Twin counter

                       counter

    Screen dis-                       Present                              Present     Batch count       Dual count  CP1 present            Present              Present

    played in run   Present value/    value/set        Total count        value/set    value/batch       value/dual          value/CP2      value 1/Set  value 2/Set

    mode            set value (1, 2)    value             value            value             count set   count set           present        value 1              value 2

                                                                                             value          value                value

                    Present value     Present value and output            Present value and output       Only the CP1 present value is      Only the CP1 present value is

    Reset/reset 1   and output                    reset.                             reset.                          reset.                              reset.

                       reset.

    Total reset or     No effect      Only the total count value is     Batch count value and batch      Only the CP2 present value is      Only the CP2 present value is

    reset 2                                       reset.                      output reset.                          reset.                              reset.

                                                          Present                            Present

                    Present value     Present value       value, total  Present value  value, batch      CP1 present value, CP2

    Reset Key       and output        and output       count value,      and output    count value,      present value, dual count          CP1 present  CP2 present

                       reset.           reset.            and output       reset.            output and  value, and output reset.           value reset  value reset

                                                          reset.                       batch output

                                                                                             reset.

    • The following table shows the delay from when the present value passes the set value               until  the  output  is  produced.

    Actual measurements in N and K-2 modes (Reference values)

    Control output type        Max. counting speed        Output delay time

    Contact output                    30 Hz               16.5 to 24.0 ms

                                      5 kHz               3.7 to 5.6 ms

    Transistor output                 30 Hz               12.0 to 20.0 ms

                                      5 kHz               0.2 to 0.55 ms

Note: The above times may vary slightly depending on the mode or operating conditions.

26
                                                                                                                                                     H7CX-A@-N

                                                                                                                                                        Tachometer

Setting Procedure Guide

Tachometer Operation

Step1       The H7CX is factory-set to the 2-stage counter configuration                                      (1-stage counter configuration for

            H7CX-AU@-N models).

            Enter configuration selection mode using the following chart                                      and set the tachometer mode.

            Note:          Step2  can be performed first, followed by         Step1      .

            Power ON                               Configuration

                                                   selection mode

                                     +    1

                           Hold down for 1 s min.

            Run mode                                                      Switch from 2cnt (2-stage           preset counter mode) to taco (tachometer  mode)

                                     +    1                               using the U Key.

                           Hold down for 1 s min.

Step2       Set the basic parameters.

            (If the desired I/O mode is not                  listed  below or     to  set all parameters             using the  front  panel  keys,  perform  Step3   ,

            below.)               Key-protect switch

                                                                                            Be sure to set pin       1 to ON.

                                                                              ON

                                                                             OFF      1  2  3  4  5  6  7  8

                      Item                         OFF               ON                                       Pin 3                    Pin 4         Tachometer output mode

1           DIP switch settings                    Disabled          Enabled                                  OFF                      OFF           Upper/lower limit output

2           Counting speed                         30 Hz             10 kHz                                   ON                       OFF              Range output

3                                                                                                             OFF                      ON            Upper limit output

4           Tachometer output mode           Refer to the table on the right.                                 ON                       ON            Lower limit output

5           Average processing

6                                            Refer to the table on the right.                                 Pin 5                    Pin 6         Average processing

7                     ---                          ---               ---                                      OFF                      OFF                    OFF

8           Input selection                        NPN               PNP                                      ON                       OFF              2 times

Note:  All  pins are factory-set to OFF.                                                                      OFF                      ON               4 times

                                                                                                              ON                       ON               8 times

• When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON.

• DIP switch settings are effective when the power is turned ON again. (Perform DIP switch                                      settings      while  the power is OFF.)

After making DIP switch settings for basic operations, advanced functions can be added using the operation keys.

For details, refer to page page 28.

                                                                                                                                                                               27
H7CX-A@-N

Tachometer

    Step3                      Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel.

    Change to Function Setting Mode.

                               Power ON                                            For details on operations and display in run mode, refer to page page 33.

                                                    3 s min.*1

                               Run mode                     Function

                                                           setting mode

                                                    3 s min.*2

                           *1  If the mode is switched to the function setting mode during operation, operation will continue.

                           *2  Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.

                               Also, when settings are changed, the counter is reset (measured value initialized and outputs turned OFF) on returning to run mode.

                                                                The characters displayed in reverse video are the default settings.

                                                                When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).

                                                                If pin 1 of the DIP switch is set to ON, the setting items indicated by                will not be displayed.

                                             Tachometer         • Set the tachometer input mode using the U Key.

                                             input mode

                                             (TINM)                      f1        f2             f3         f4     f5                                 *1 Set tachometer output modes 1 and 2 using the

                                                                      (1 input)    (2 inputs)  (Error) (Absolute ratio) (Error ratio)                  U Key.

                                                                                                                                                       * Displayed only when the tachometer input mode is F2

                                                       *1                                                                                              (2 inputs).

                                             Tachometer         • Set the tachometer output mode using the U Key.                                                          Tachometer  hi    lo

                                             output mode                                                                                                                   output

                                             (TOTM)                                                                                                                        mode 1      (HI)  (LO)

                                                                      hilo         area           hihi           lolo                                                      (TO1M)

                                                                      (HI-LO)      (AREA)         (HI-HI)        (LO-LO)

                                                                                                                                                                           Tachometer  hi    lo

                                             Counting           • Set the counting speed using the U Key.                                                                  output

                                             speed                                                                                                                         mode 2      (HI)  (LO)

                                             (CNTS)                                                                                                                        (TO2M)

                                                                      30hz

                                                                      (30 Hz)      (10 kHz)

                                                                Note: Even if 10 kHz is selected when the tachometer input mode is F2 to F5, the counting speed will be 5 kHz.

                                             Decimal point      • Set the decimal point position using the U Key.

                                             position

                                             (DP)                                                                                                      --.----

    Function Setting Mode                                       (No decimal point)       (One digit after    (Two digits after  (Three digits after    (Four digits after

                                                                                             decimal point)  decimal point)            decimal point)  decimal point)

                                                                Note: “--.----“ will be displayed when pulse width measurement is set or when the display unit is set to seconds.

                                             Prescale           • Set each digit using the individual U Key.

                                             value

                                             (PSCL)                   0.001        1.000          99.999

                                                                      (0.001)      (1.000)        (99.999)

                                             Averaging          • Set the averaging method using the U Key.

                                             method

                                             (AVGT)

                                                                         smp             mv

                                                                      (Simple      (Moving

                                                                averaging)         average)

                                             Average            • Set the number of averaging times using the U Key.

                                             processing

                                             (AVGN)

                                                                         off             2            4          8                     16

                                                                      (No average  (Average of 2  (Average of 4  (Average of 8         (Average of 16

                                                                      processing)  measurements) measurements) measurements)           measurements)

                                             Auto-zero          • Set each digit using the individual U Key.

                                             time

                                             (AUT00)

                                                                      0.1          999.9

                                                                      (0.1 s)      (999.9 s)

                                             Startup time       • Set each digit using the individual U Key.

                                             (STMR)

                                                                      0.0          99.9

                                                                      (0.0 s)      (99.9 s)

    From next page             To next page

28
                                                                                                                                                                                                 H7CX-A@-N

                                                                                                                                                                                                    Tachometer

To previous                  From previous

                       page  page

                                                NPN/PNP          • Set the NPN/PNP input mode using the U Key.

                                                input mode

                                                (IMOD)

                                                                        npn       pnp

                                                                 (NPN input) (PNP input)

                                                Display          • Set the display color using the U Key.

                                                color

                                                (COLR)                  red       grn           org     r-g    g-r        r-o               o-r           g-o             o-g

                                                                 (Red)            (Green)    (Orange) (Red-green) (Green-red) (Red-orange)  (Orange-red)  (Green-orange)  (Orange-green)

                                                Peak/bottom      • Enable or disable the peak/bottom hold using the          U              Key.

                                                hold enabled

                                                (DHLD)                  off          on

                                                                 (Disabled)       (Enabled)

                                                Output           • Set the output hysteresis using the U Key.

                                                hysteresis

                                                (HYS)                   0         99999

                                                                        (0)       (99999)

                                                                 Note: The measurement value after prescaling is set.

                                                Output OFF       • Set each digit using the individual U Key.

                                                delay

                                                (OFFD)                  0.00         19.99

Function Setting Mode                                                   (0.00 s)     (19.99 s)

                                                Set value        • Set each digit using the individual U Key.

                                                upper limit

                                                (SL-H)                                   999999

                                                                             1

                                                                        (1)              (999999)

                                                Output                  off            on

                                                allocation              (OFF)        (ON)

                                                change

                                                                 Note: Displayed only for "-AU@" models.

                                                                        off: Output 1 = 12, 13, Output 2 = 3, 4, 5

                                                                        on: Output 1 = 3, 4, 5, Output 2 = 12, 13

                                                                        The numbers are the terminals numbers.

                                                Key protect      • Set the key protect level using the U Key.

                                                level

                                                (KYPT)                  kp-1         kp-2       kp-3         kp-4    kp-5                   kp-6          kp-7

                                                                        (KP-1)    (KP-2)        (KP-3)       (KP-4)  (KP-5)                 (KP-6)        (KP-7)

                                                Pulse cycle

                                                measurement/     • Set pulse cycle measurement or pulse width measurement using the U Key.

                                                pulse width

                                                measurement             phas

                                                (CALM)           (Pulse cycle     (Pulse width

                                                                 measurement) measurement)                                   *2 Set each digit using the individual U Keys.

                                                Display unit     • Set the display unit using the U Key.                                                  Output 1

                                                (UNIT)                                                                                                    (OUT1) ON                              0  9999

                                                                        hz        s                                                                       count alarm                     (0 × 1000 times) (9999 × 1000 times)

                                                                                                                                                          set value

                                                                        (Hz)      (s)

                                                                 Note:  Displayed only when pulse cycle measurement is

                                                                        used.

                                                Measurement                                                                                               Output 2

                                                                 • Set each digit using the individual U Key.                                             (OUT2) ON

                                                interval                                                                                                  count alarm                            0  9999

                                                (INTV)                                                                                                    set value                       (0 × 1000 times) (9999 × 1000 times)

                                                                        200ms          cont

                                                                        (200 ms) (Cont (10 ms min.))

                                            *2                   Note: Displayed only if the measurement speed is 10 kHz                                  Output 1

                                                                        when pulse cycle measurement is used.                                             (OUT1) ON                       Note:  The monitor value is only

                                                Output ON                                                                                                 count monitor                          displayed. It cannot be set.

                                                count alarm set                                                                                           value

                                                value/monitor

                                                value

                                                                                                                                                               Output 2

                                                                                                                                                               (OUT2) ON                  Note:  The monitor value is only

                                                                                                                                                               count                             displayed. It cannot be set.

                                                                                                                                                               monitor value

                                                                                                                                                                                                                                29
H7CX-A@-N

Tachometer

Explanation of Functions

Tachometer Operation

Items marked with stars ★ can be set using the DIP                                  N: Number of pulses per revolution

switch.                                                                             d: Diameter of rotating body (m)                                d: Diameter

Tachometer Input Mode (tinm)                                                        πd: Circumference (m)                                             of rotating

Set the count input mode to one of the following: 1 input (F1), 2 inputs                                                                              body (m)

(F2), error (F3), absolute ratio (F4), or error ratio (F5).                            •  Observe the following points when

    Input             Input       Internal              Application                       setting a prescale value.

    mode                          processing                                              Set the set value to a value less than {Maximum countable value −

    1 input      Count 1          None              Operation with only one input.        Prescale value}.

    2 inputs     Counts 1 and  2  None              Operation with two                    Example: If the prescale value is 1.25 and the counting range is

                                                    independent inputs.                   0.000 to 999.999, set the set value to a value less than 998.749 (=

                                  Count 1 input −   Measuring the difference              999.999 − 1.25).

    Error        Counts 1 and  2  Count 2 input     between two inputs (error in          If the set value is set to a value greater than this, output will not turn

                                                    number of revolutions).               ON.

                                                    Measuring the ratio of two      *     Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF}.

    Absolute     Counts 1 and  2  Count 1 input ÷   inputs (ratio of number of

    ratio                         Count 2 input     revolutions).                      Note: If the prescale value setting is incorrect, a counting error will

                                                                                               occur. Check that the settings are correct before using this

                                  (Count 1 input −  Measuring the ratio of error               function.

    Error ratio  Counts 1 and  2  Count 2 input) ÷  for two inputs (measuring the

                                  Count 2 input     error ratio of number of

                                                    revolutions).                   Averaging Method (avgt) (Only for Tachometer Operation)

Tachometer Output Mode (totm)★                                                      A simple average or moving average can be selected for the

                                                                                    averaging.  With the moving average method, the average of the

Set the output method for control output based on the comparison                    measurement values is displayed each sampling cycle, in contrast to

value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI-HI),             a simple average, with which the the average of the set number of

and lower limit (LO-LO) can be set.                                                 samples is displayed.

(For details on the output modes, refer to Output Mode Settings and

Operation on page page 34.)                                                         Number of Averaging Times (avgn)★

Counting Speed (cnts)★                                                              Flickering display and output chattering can be prevented using

Set the maximum counting speed (30 Hz/10 kHz) for CP1 input.                        average processing. Average processing can be set to one of four

If contacts are used for input signals, set the counting speed to 30 Hz.            levels: no average processing, 2 times (i.e., the average of 2

Processing to eliminate chattering is performed for this setting.                   measurement values), 4 times, 8 times, or 16 times.

                                                                                    The measurement cycle will be equal to the sampling cycle multiplied

Decimal Point Position (dp)                                                         by the average processing setting (i.e., the number of times).

Decide the decimal point position for the measurement value, OUT1                   Average processing enables stable displays even for fluctuating input

set value, and OUT2 set value.                                                      signals. Set the optimum number of times for the application.

Prescale Value (pscl)                                                               Auto-zero Time (auto0)

It is possible to display the rate of rotation or the speed of a device or          The display can be force-set to 0 if there is no pulse for a certain

machine to which the H7CX is mounted by converting input pulses to                  period of time. This time is called the auto-zero time. Set the auto-zero

a desired unit.                                                                     time to a time slightly longer than the estimated interval between input

If this prescaling function is not used, the input frequency (Hz) will be           pulses. Accurate measurement is not possible if the auto-zero time is

displayed.                                                                          set to a time shorter than the input pulse cycle. Setting a time that is

It is also possible to specify time (seconds) as the display value. Refer           too long may also result in problems, such as a time-lag between

to Display Unit on page page 31 for details.                                        rotation stopping and the alarm turning ON. The auto-zero time is not

The relationship between display and input is determined by the                     applied to pulse width measurements.

following equation. Set the prescale value according to the unit to be              Startup Time (stmr)

displayed.                                                                          To prevent undesired outputs resulting from unstable inputs

Displayed value = f × α                                                             immediately after the power supply is turned ON, it is possible to

f: Input pulse frequency (number of pulses in 1 second)                             prohibit measurement for a set period of time, the startup time.

α: Prescale value                                                                   It can also be used to stop measurements and disable outputs until

                                                                                    the rotating body reaches the normal rate of rotation, after the power

(1) Displaying Rotation Rate                                                        supply to the H7CX and rotating body are turned ON at the same time.

              Display unit                          Prescale value (α)                                      Display        Startup time

                 rpm                                1/N × 60                                    Comparison value

                 rps                                    1/N                                                 (lower limit)

N: Number of pulses per revolution

Example: To display the rate of rotation for a machine that outputs 5                                                                               Time

pulses per revolution in the form @@.@ rpm:

1. Set the decimal point position to 1 decimal places.                                                      Power supply

2. Using the formula, set the prescale value (α) to 1/N × 60 = 60/5 = 12.                                   Output

                                                                                                            (lower limit)

(2) Displaying Speed

              Display unit                          Prescale value (α)

                 m/min                              πd × 1/N × 60

                 m/s                                πd × 1/N

30
                                                                                                                                                H7CX-A@-N

                                                                                                                                                Tachometer

NPN/PNP Input Mode (imod)★                                                         Output Hysteresis (hys)

Select either NPN input (no-voltage input) or PNP input (voltage                   This setting can be used to prevent output chattering if the

input) as the input format.                                                        measurement value fluctuates slightly near the set value.

When using a two-wire sensor, select NPN input. The same setting is                The measurement value after prescaling is set.

used for all external inputs.

For details on input connections, refer to Input Connections on page                          Comparison value 2            Hysteresis

page 9.

                                                                                                    Display value

Display Color (colr)                                                                          Comparison value 1                                Hysteresis

Set the color used for the measurement value.

                              Control output OFF       Control output ON

                                                                                                        OUTX1

         red                                   Red (fixed)

         grn                             Green (fixed)                                                  OUTY2

         org                             Orange (fixed)                                                            Set the hysteresis for when

                                                                                                                   the output turns OFF.

                              Measured value is        Measured value is

         r-g *1               displayed in red when    displayed in green when     Output OFF Delay (offd)

                              both control outputs 1   either control output 1 or  This function delays the timing for turning OFF comparative output by

                               and 2 are OFF.          control output 2 is ON.     a certain time.

                              Measured value is        Measured value is           The ON time can be held for the set time if the comparative result

         g-r *2               displayed in green when  displayed in red when       changes in a short time.

                              both control outputs 1   either control output 1 or  Operation will continue and outputs will not change when holding the

                               and 2 are OFF.          control output 2 is ON.     value.

                              Measured value is        Measured value is

                              displayed in red when    displayed in orange         Set Value Upper Limit (pl-h)

         r-o *3               both control outputs 1   when both control           Set the upper limit for the set value when it is set in run mode. The

                               and 2 are OFF.          outputs 1 and 2 are         limit can be set to between 1 and 999999.

                                                            OFF.

                              Measured value is        Measured value is           Output Allocation (otst)

                              displayed in orange      displayed in red when       When using an H7CX-AU@-N model as 2-stage counter, each output

         o-r *4                when both control       both control outputs 1

                              outputs 1 and 2 are           and 2 are OFF.         can be flexibly allocated to either stage 1 or 2.

                                   OFF.                                            The transistor output can be allocated to SV1 and the contact output

                              Measured value is        Measured value is           to SV2 or vice verse, as in the following tables.

                              displayed in green when  displayed in orange

         g-o *5               both control outputs 1   when both control           H7CX-AU-N/-AUD1-N

                               and 2 are OFF.          outputs 1 and 2 are                              Output 1                                Output 2

                                                            OFF.

                              Measured value is                                    off     Transistor (12-13)               Contact (3, 4, 5)

                              displayed in orange      Measured value is           on      Contact (3, 4, 5)                Transistor (12-13)

         o-g *6                when both control       displayed in green when

                              outputs 1 and 2 are      both control outputs 1

                                   OFF.                     and 2 are OFF.         H7CX-AUSD1-N

*1.  If the tachometer output mode is set to AREA, however, the measured                                Output 1                                Output 2

     value is displayed in red when control output 1 is OFF and in green when      off     Transistor (12-13)               Transistor with diode (3, 4, 5)

     control output 1 is ON.                                                       on      Transistor with diode (3, 4, 5)  Transistor (12-13)

*2.  If the tachometer output mode is set to AREA, however, the measured

     value is displayed in green when control output 1 is OFF and in red when

     control output 1 is ON.                                                       Key Protect Level (kypt)

*3.  If the tachometer output mode is set to AREA, however, the measured

     value is displayed in red when control output 1 is OFF and in orange when     Set the key protect level.

     control output 1 is ON.                                                       Refer to Key Protect Level on page page 36.

*4.  If the tachometer output mode is set to AREA, however, the measured

     value is displayed in orange when control output 1 is OFF and in red when

     control output 1 is ON.                                                       Pulse Cycle Measurement/Pulse Width Measurement

*5.  If the tachometer output mode is set to AREA, however, the measured           (calm)

     value is displayed in green when control output 1 is OFF and in orange        Set the measurement mode to pulse cycle measurement or pulse

     when control output 1 is ON.

*6.  If the tachometer output mode is set to AREA, however, the measured           width measurement.

     value is displayed in orange when control output 1 is OFF and in green        With pulse cycle measurement, the number of pulse cycles that occur

     when control output 1 is ON.                                                  in 1 s is measured.

Peak/bottom Hold Enabled (dhld)                                                    With pulse width measurement, the ON time for one pulse is

This function records the peak and bottom (i.e., minimum) after                    measured.

counting starts (after turning ON the power supply or changing the                 An input OFF period of at least 20 ms is required for pulse width

configuration selection mode or function setting). The peak value is               measurement.

also held when the power supply is interrupted.                                    If there is no input pulse during pulse width measurement, the

                                                                                   previously measured value will be held.

                                                                                   Display Unit (unit)

                                                                                   When pulse cycle measurement is used, set the display unit to Hz

                                                                                   (hertz) or s (seconds).

                                                                                   Counting Interval (intv)

                                                                                   If the measurement speed is 10 kHz when pulse cycle measurement

                                                                                   is used, set the measurement interval to 200 ms or Cont (10 ms min.).

                                                                                                                                                             31
H7CX-A@-N

Tachometer

ON Count Alarm Set Values for Outputs 1 and 2 (OUT1

and OUT2) (on1a and on2a)

Set the ON count alarm values for the outputs 1 and 2.

The limit can be set to between 0 × 1000 (0 times) and 9999 × 1000

(9,999,000 times). Only the underlined values are set. The alarm will

be disabled if 0 is set.

If the total ON count of instantaneous output 1 or 2 exceeds the alarm

set value, e3 will be displayed on the Timer to indicate that the output

ON count alarm value was exceeded. Refer to Self-diagnostic

Function on page page 36 for information on the e3 display.

ON Count Monitor Values for Outputs 1 and 2 (OUT1 and

OUT2) (on1c and on2c)

The monitor value for output 1 or 2 is only displayed. It cannot be set.

The output ON count will be 1,000 times the displayed value.

32
                                                                                                                                           H7CX-A@-N

                                                                                                                                           Tachometer

Operation in Run Mode

Tachometer Operation

• Set each digit using the individual U Keys.

                                  Measurement value       •  Measurement value

                                                             Displays the currently measured value.

                                                          •  Comparison value 1/Comparison value 2

                                                      *1     Set comparison value 1 and comparison value 2.

                                  Measurement value 1        The measurement value is compared to

                                  Comparison value 1         comparison value 1 and comparison value 2 and

                                                             output is made according to the selected output

                                                             mode.

                                                      *2

                                  Measurement value 2

                                  Comparison value 2

                              *3

*1  Measurement value 1 for the 2-input input mode.

*2  Measurement value 2 for the 2-input input mode.

*3  Peak/bottom hold enabled

    Displayed when the input mode is not 2 inputs.           Displayed  for  the  2-input input mode.

                                                                                                              •  Peak/bottom hold value

    Peak hold value                                                               Peak hold value 1              The peak (maximum) and bottom (minimum)

                                                                                                                 values are displayed after counting starts.

                                                                                                              •  Peak/bottom hold value 2

                                                                                                                 Peaks (maximums) 1 and 2 and bottoms

    Bottom hold value                                                             Bottom hold value 1            (minimums) 1 and 2 are displayed after counting

                                                                                                                 starts.

                                                                                                                 Note:    The held values will be initialized when

                                                                                                                          the Reset Key (Hold Key) or reset 1 input

                                                                                                                          is turned OFF while peak/bottom hold

                                                                                                                          values 1 and 2 are being displayed. (The

                                                                                  Peak hold value 2                       reset 2 input operates in the same way if

                                                                                                                          the input mode is set to 2-input mode.)

                                                                                  Bottom hold value 2

                                                                                                                                                                     33
H7CX-A@-N

Output Mode Setting              and Operation

Tachometer Operation

    Input mode      Output mode                                                            Operation

    setting         setting

                                 (Upper-limit)

                                 Comparison value 2

                                 Measurement value

                    Upper and    (Lower-limit)                                      ON condition for OUT1: Measurement value       ≤  Comparison value 1

                    lower limit  Comparison value 1                                 ON condition for OUT2: Measurement value       ≥  Comparison value 2

                    (HI-LO)

                                           OUT1

                                           OUT2

                                 Comparison value 2                                 Condition         Comparison value 1 ≤            Measurement value 1    >

                                                                                                      Comparison value 2              Comparison value 2

                                 Measurement value                                                    Comparison value 1 ≤            Comparison value 2 ≤

                                                                                    ON condition      Measurement value ≤             Measurement value ≤

                                 Comparison value 1                                 for OUT1          Comparison value 2              Comparison value 1

                    Area (AREA)

                                                                                                      Measurement value <             Measurement value <

                                           OUT1                                     ON condition      Comparison value 1 or           Comparison value 2 or

                                                                                    for OUT2          Measurement value >             Measurement value >

                                                                                                      Comparison value 2              Comparison value 1

    1 input                                OUT2

    Error

    Absolute ratio

    Error ratio                  (Upper-limit)

                                 Comparison value 2

                                 Measurement value

                                 (Lower-limit)                                      ON condition for OUT1: Measurement value       ≥  Comparison value 1

                    Upper limit  Comparison value 1

                    (HI-HI)                                                         ON condition for OUT2: Measurement value       ≥  Comparison value 2

                                           OUT1

                                           OUT2

                                 (Upper-limit)

                                 Comparison value 2

                                 Measurement value

                    Lower limit  (Lower-limit)                                      ON condition for OUT1: Measurement value       ≤  Comparison value 1

                                 Comparison value 1                                 ON condition for OUT2: Measurement value       ≤  Comparison value 2

                    (LO-LO)

                                           OUT1

                                           OUT2

                                 Output 1                                                  Output 2

                                 Comparison value 1                                        Comparison value 2

                                 CP1 display value                                            CP2 display value

                    Upper limit

                    (HI)

                                           OUT1                                                       OUT2

                                 ON condition        for  output  1:  CP1  present  value  (display value) ≥ Comparison  value  1

                                 ON condition        for  output  2:  CP2  present  value  (display value) ≥ Comparison  value  2

    2 inputs

                                 Output 1                                                  Output 2

                                 CP1 display value                                            CP2 display value

                    Lower limit

                    (LO)         Comparison value 1                                        Comparison value 2

                                           OUT1                                                       OUT2

                                 ON condition        for  output  1:  CP1  present  value  (display value) ≤ Comparison  value  1

                                 ON condition        for  output  2:  CP2  present  value  (display value) ≤ Comparison  value  2

34
                                                                                                                                                                  H7CX-A@-N

Switching between Preset Counter, Total and Preset Counter, Batch Counter, Dual

Counter, Twin Counter, and Tachometer Operation

Select which H7CX configuration is used (i.e., preset counter, total and preset counter, batch counter, dual counter, twin counter, or tachometer)

in configuration selection mode.

The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be

confirmed using the display on the front of the H7CX.

                                               Power ON

                                                                                                                                                             RST

Run mode                                                                                                                                  1

                                                                               Key                                              Key           Key                                       1

                                                                                                                                                                                        Key

                                                                               Note

                                               +                               To change the mode to configuration selection mode, hold

                                           *2  1            *1                 down the            1 Key for 1 s min. with the                Key held down.

                                               Press the                       The mode will not change if the                  1 Key is pressed first.

                                               key for 1 s

                                               min.

Configuration Selection Mode                                                   Select the configuration using the UD Key.

                                                                Configuration

                                                                selection      1cnt                   2cnt          tcnt        bcnt               dcnt           twn       taco

                                                                               (1-stage            (2-stage         (Total and  (Batch             (Dual          (Twin     (Tachometer)

                                                                               preset              preset           preset counter) counter)       counter)       counter)

                                                                               counter)            counter)

                                                                               *The configurations that can be selected depend on the model.

                                                                               Note:      By default, the H7CX is set to the 1-stage preset counter configuration. (Two-stage

                                                                                          models are set to the 2-stage preset counter configuration.)

                                                                Convenient     Confirm the status of DIP switch pins 1 to 8 using the UD Key.

                                                                DIP switch     *This display is possible only when DIP switch pin 1 (DIP switch settings enable/disable)

                                                                monitor        is set to ON (enable).

                                                                (DIP)                     Example

                                                                               ON

                                                                               OFF        1  2  3  4    5  6  7  8

                                                                                                                                              …Indicates that DIP switch pin 8 is ON.

                                                                                                                                              …Indicates that DIP switch pin 7 is OFF.

                                                                                                                                              …Indicates that DIP switch pin 6 is ON.

                                                                                                                                              …Indicates that DIP switch pin 5 is OFF.

                                                                                                                                              …Indicates that DIP switch pin 4 is ON.

                                                                                                                                              …Indicates that DIP switch pin 3 is OFF.

                                                                                                                                              …Indicates that DIP switch pin 2 is ON.

                                                                                                                                              …Indicates that DIP switch pin 1 is ON.

*1 When the mode is changed to configuration selection mode, the present value is reset, outputs turn OFF, and counting (measuring) stops.

*2 Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is changed, the

set value (or set value 1 and set value 2), comparison value 1 and comparison value 2 are initialized.

Hold Function

The measurement value (display value) and output are sustained while the hold input is ON.

Note: The output will maintain the current status when the hold key is pressed.

Example:

Output mode                                                                    Operation

                              setting

                                               Hold input* (Reset Key)

                                                                                          Actual input

                                                         Display value

                              Lower limit  Comparison value (lower limit)

                                                                                                                 Sustained display value

                                                                                                           Sustained output

                                                                OUT

                                                                                                                                                                                             35
H7CX-A@-N

Key Protect Level

It is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1                    to  KP-7)  when            the

key-protect switch is set to ON.

The key protect level is set in the function setting mode. The key protect indicator is lit when the key-protect switch is ON.

                                                      * OFF      ON

                                                 (Disable)       (Enable)

                                         *Factory-set to OFF

                                                              Key protect indicator

                                                                                                                      Details

     Level                        Description                                Changing modes*       Switching display                 Reset Key         Up/Down Keys

                                                                                                   during operation

     KP-1                                                                      Invalid                   Valid                       Valid                 Valid

    (default setting)

     KP-2                                                                      Invalid                   Valid                       Invalid               Valid

     KP-3                                                                      Invalid                   Valid                       Valid                 Invalid

     KP-4                                                                      Invalid                   Valid                       Invalid               Invalid

     KP-5                                                                      Invalid                   Invalid                     Invalid               Invalid

     KP-6                                                                      Invalid                   Invalid                     Valid                 Valid

     KP-7                                                                      Invalid                   Invalid                     Invalid               Valid

*   Changing mode to configuration selection mode or function setting mode.

Self-diagnostic Function

The following displays will appear if an error occurs.

     Main display                Sub-display                  Description                     Output status           Correction method                Set value after reset

     ----- (----)*1*5             No change           Present value underflow*3               No change           Either press the Reset Key or turn       No change

                                                                                                                  ON reset input.

     fffff (ffff)*1*5             No change           Present value overflow*4                No change           Either press the Reset Key or turn       No change

                                                                                                                  ON reset input.*6

     e1                                 Not lit       CPU error                                    OFF            Either press the Reset Key or            No change

                                                                                                                  reset the power supply.

     e2                                 Not lit       Memory error (RAM)                           OFF            Turn ON the power again.                 No change

     e2                                  sum          Memory error (EEPROM)*2                      OFF            Reset Key                            Factory setting

     e3*8                         No change           Output Counter Overflow                 No change           Reset Key*7                              No change

*1.  Displays for 4-digit models are given in parentheses.                                    *7.  This is displayed if the alarm value setting for either of the two outputs is

*2.  This includes times when the life of the EEPROM has expired.                                  exceeded if a model with two outputs is used.The total ON count will not be

*3.  This occurs if the present value or total count value falls below −99999                      cleared by using the Reset Key.

     (−999 for 4-digit models).                                                               *8.  The normal display and e3 will appear alternately.

*4.  This occurs in the following conditions if the present value (i.e.,                           When the Reset Key is pressed, e3 will not be displayed even if the alarm

     measurement value) exceeds 999999 (9999 for 4-digit models).                                  set value is exceeded.

     • For Output Modes K-2, D, L, or H                                                            (Monitoring is possible, however, because the counter will continue without

     • Dual counter or tachometer operation is used.                                               the output ON count being cleared.)

*5.  Display flashes.(1-second cycles)

*6.  This does not apply when tachometer operation is used.

36
                                                                                                                                              H7CX-R@-N

                       H7CX-R@-N Tachometer

• Tachometer-only model (DIN 48 × 48) for the H7CX

     (Supports display and alarm outputs for numbers of rotations,

     speed, and flow rate.)

• Socket design allows either flush or surface mounting.

• "-W" models added to provide two sets of measurement controls. *

• Operation in any of the four following modes is possible with the

     same Unit: Upper and lower limit, upper limit, lower limit, and area.

• Equipped with auto-zero time, average processing, and startup

     time functions.                                                                               For the most recent information on models that have been certified for

* The prescale value and auto-zero time settings are one.                                          safety standards, refer to your OMRON website.

Specifications

Ratings

                   Classification                                                                  Tachometer

Item                       Model                                         H7CX-R11@-N                                                     H7CX-R11W@-N

Input mode                         1 input only                                                                          2 inputs only

            Power supply volt-     • 100 to 240 VAC, 50/60 Hz

            age*1                  • 12 to 24 VDC or 24 VAC, 50/60 Hz

Ratings     Operating voltage      85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC)

            fluctuation range

            Power consumption      Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at 12 to 24 VDC

Mounting method                    Flush mounting or surface mounting

External connections               11-pin socket

Degree of protection               IEC IP66, UL508 Type 4 (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used

Input signals                      Count and hold                                                                        Count 1 and count 2

Pulse measurement method           Tachometer mode (cycle measurement)          AMD-compatible mode (continuous          Tachometer mode (cycle measurement)

                                                                                measurement)

                                   30 Hz                   10 kHz                                                        30 Hz (minimum pulse width: 16.7 ms) or 5 kHz

Maximum counting speed             (minimum pulse          (minimum pulse                           ---                  (minimum pulse width: 0.1 ms) (selectable)

                                   width: 16.7 ms)         width: 0.05 ms)

Minimum input signal width                              ---                     10 ms               1 ms                                           ---

Measuring ranges                   0.001 Hz to 30.00Hz     0.001 Hz to 10 kHz   0.026 to 999999 s   0.003 to 999999 s    0.01 to 5k Hz

Sampling cycle                     200 ms min.                                  Continuous measurement (minimum          200 ms min.

                                                                                interval of 10 ms)

                                   • Input pulse of 5 Hz min.

                                   Averaging not used: 200 ms

Display refresh cycle              Averaging used: 200 multiplied by the averaging setting (ms)

                                   • Input pulse of less than 5 Hz

                                   Averaging not used: Two times the maximum input pulse cycle

                                   Using averaging: Two times the maximum of the input pulse cycle multiplied by the averaging setting.

Measuring accuracy                 ±0.1% FS ±1 digit max. (at 23 ±5°C)

Output mode                        HI-LO, AREA, HI-HI, LO-LO                                                             HI-HI, LO-LO

Auto-zero time                     0.1 to 999.9 s (in Tachometer Mode)

Startup time                       0.0 to 99.9 s

Averaging                          Simple averaging/moving averaging selectable, Number of times: OFF, 2, 4, or 8 times

Prescaling function                0.001 to 99.999 (in Tachometer Mode)

Decimal point adjustment           Rightmost 3 digits                                                                                              ---

Sensor waiting time                290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)

                                   No-voltage Input

                                   Impedance when ON:          1 kΩ max.

                                                               (Leakage current: 12 mA when 0 Ω)

                                   ON residual voltage:        3 V max.

            Input method           Impedance when OFF: 100 kΩ min.

Input                              Voltage Input

                                   High (logic) level:         4.5 to 30 VDC

                                   Low (logic) level:          0 to 2 VDC

                                                               (Input resistance: approx. 4.7 kΩ)

                                   No-voltage input/voltage input (selectable)

            Hold input             Minimum input signal width: 20 ms                                                                               ---

External power supply              12 VDC (±10%), 100 mA

                                   * Refer to Safety Precautions (Common) on page page 52 for details.

Control output                     Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1)

                                   Minimum applied load:10 mA at 5 VDC (failure level: P, reference value)

                                   7-segment, negative transmissive LCD

Display*2                          Character height

                                   Present value: 10 mm (red), comparison value: 6 mm (green)

Digits                             6 digits (0 to 999999)

Memory backup                      EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.

Operating temperature range        −10 to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)

Storage temperature range          −25 to 70°C (with no icing or condensation)

Operating humidity range           25% to 85%

Case color                         Black (N1.5)

*1.  Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for CC power.

*2.  The display is lit only when the power is ON. Nothing is displayed when power is OFF.

                                                                                                                                                                           37
H7CX-R@-N

Characteristics

    Insulation resistance        100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-                           Life-test Curve

                                 current-carrying metal parts, and between non-continuous contacts                                     (Reference Values)

                                 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-                                              Resistive Load

                                 carrying metal parts

    Dielectric strength          2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input                     No. of operations ( ×103)  1,000

                                 circuit (1,000 VAC for 24 VAC/12 to 24 VDC)                                                                                      700

                                 2,000 VAC 50/60 Hz for 1 min between control output, power supply, and input circuit                                             500

                                 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts

                                 3.0 kV (between power terminals) for 100 to 240 VAC, 1.0 kV for 24 VAC/12 to 24 VDC                                              300

    Impulse withstand voltage    4.5 kV (between current-carrying terminal and exposed non-current-carrying metal                                                              30 VDC (cosφ=1)

                                 parts) for 100 to 240 VAC, 1.5 kV for 24 VAC/12 to 24 VDC

                                 ±1.5 kV (between power terminals)

    Noise immunity               ±600 V (between input terminals)                                                                                                 100       250 VAC (cosφ=1)

                                 Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)

    Static immunity              Destruction: 15 kV, Malfunction: 8 kV                                                                                            70

    Vibration   Destruction      10 to 55 Hz with 0.75-mm single amplitude, each in three directions for 2 hours                                                  50

                                                                                                                                                                         0  1                 2       3           4

    resistance  Malfunction      10 to 55 Hz with 0.35-mm single amplitude, each in three directions for 10 min                                                                                  Load    current  (A)

    Shock re-   Destruction      300m/s2 each in three directions, three cycles                                                                                   Inductive Load

    sistance    Malfunction      100m/s2 each in three directions, three cycles                                                        No. of operations ( ×103)  1,000

                                 Mechanical: 10,000,000 operations min.                                                                                           700

    Life expectancy              Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient

                                 temperature condition: 23°C) *                                                                                                   500

    Weight                       Approx. 110 g (Tachometer only)

                                                                                                                                                                  300

*   See Life-test Curve (Reference Values) on the right.                                                                                                                       30 VDC (L/R=7     ms)

Applicable Standards

    Approved    cULus (or cURus): UL508/CSA C22.2 No. 14*                                                                                                         100

    safety      Conforms to EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II, B300 PILOT DUTY,                                                          250 VAC (cosφ=1)

    standards   1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3-A resistive load                                                                                               70

                (EMI)                                        EN61326                                                                                              50

                                                                                                                                                                         0  1                 2       3           4

                Emission Enclosure:                          EN55011  Group 1    classA                                                                                                          Load current (A)

                Emission AC mains:                           EN55011  Group 1    classA                                                A current of 0.15 A max. can be switched at

                (EMS)                                        EN61326                                                                   125 VDC (cosφ=1) (Life expectancy: 100,000

                Immunity ESD:                                EN61000-4-2:        4 kV contact discharge (level 2);                     operations)

                                                                               8 kV air discharge (level 3)                            A current of 0.1 A max. can be switched if

                Immunity RF-interference:                    EN61000-4-3:        10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)         L/R=7 ms.

    EMC                                                                        (level 3);                                              (Life expectancy: 100,000 operations)

                                                                               10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)

                Immunity Conducted Disturbance:              EN61000-4-6:        10 V (0.15 to 80 MHz) (level 3)

                Immunity Burst:                              EN61000-4-4:      2 kV power-line (level 3);

                                                                               1 kV I/O signal-line (level 4)

                Immunity Surge:                              EN61000-4-5:      1 kV line to lines (power and output lines) (level 2);

                                                                               2 kV line to ground (power and output lines) (level 3)

                Immunity Voltage Dip/Interruption:           EN61000-4-11: 0.5 cycle, 100% (rated voltage)

*   The following safety standards apply to the H7CX-R11@.

    cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.

    cUR (Recognition): Applicable when any other socket is used.

I/O Functions

                Count,

                count 1,   Reads counting signals.

    Inputs      count 2

                Hold       • Holds the measurement value and outputs.

                           • The hold indicator is lit during hold.*

    Outputs     OUT        Outputs signals according to the specified output

                           mode when a comparison value is reached.

*   Refer to page page 50 for details on the hold function.

    • The following table shows the delay from when the reset signal                       is

    input until the output is turned OFF. (Reference values)

         Minimum reset signal width                          Output delay time

                        1 ms                                      0.8 to 1.2 ms

                      20 ms                                       15 to 25 ms

38
                                                                                                                                                      H7CX-R@-N

Connections

Terminal Arrangement                                                                            Block  Diagram

H7CX-R11-N                                                                                                                      (Basic insulation)

H7CX-R11D1-N                                                                                           Output circuit                                 Power supply

                                                                                                                                                      circuit

                       Hold       *                                                                    (Basic insulation)                             (Basic insulation)

                       Count

                       Hold       *                                 Internal circuit                                                                  Display circuit

                                  *         5     6     7                                              Input circuits            Internal

                       Hold           4                     8                                                                    control circuit

                              0V                                                                                                                      Key switch

               (−)                    3                       9                                                                                       circuit

               Sensor                    2               10

                       12 VDC                  1     11

               (+)

                    External                                            OUT                     Input Circuits

                    power supply

                                         (−)         (+)                                        Count and Hold Inputs

*  The hold function is the same whichever terminal is connected. Terminals           are  not

   connected internally, and so do not use them for cross-over wiring.                          No-voltage Inputs                          Voltage Inputs

H7CX-R11W-N                                                                                     (NPN Inputs)                               (PNP Inputs)

H7CX-R11WD1-N                                        Internal circuit                                         +14V

                       Count 1                                          OUT2                           1 kΩ                                           Approx. 4.7 kΩ      Internal

                                                                                                                                                  IN                      circuit

                       Count 2                                      Internal circuit            IN                     Internal

                                               5     6     7                                                           circuit

                                         4                       8

                              0V         3                       9

               (−)                          2               10

               Sensor                             1     11

               (+)            12 VDC

                    External                                            OUT1

                    power supply

                                               (−)       (+)

                                                                                                                                                                                    39
H7CX-R@-N

Input Connections

The inputs of the H7CX-R are no-voltage (short-circuit                                                                   or  open)        inputs  or voltage inputs. They                             are           set  for       use as voltage inputs at the time                                       of

delivery.

No-voltage Inputs (NPN Inputs)

Open Collector                                                                            Voltage Output                                             Contact Input                                                                 DC Two-wire Sensor

           PLC or                                                                         Sensor,

           sensor                                                                         etc.

                       0 V for inputs                        Hold           Count                        0 V for inputs          Hold     Count                                               inputs          Hold          Count                                    inputs             Hold               Count

                                                                                                                                                                                              fo r                                                                   fo r

                                                                                                                                                                                              V                                                                      V

                                                                                                                                                                                              0                                                                      0

    H7CX-R11@       3                                  4  5    7         6                H7CX-R11@   3                  4   5   7     6                             H7CX-R11@             3          4  5    7          6         H7CX-R11@                      3          4     5    7               6

    H7CX-R11W@      3                                     ---            6                H7CX-R11W@  3                     ---        6                             H7CX-R11W@            3             ---             6         H7CX-R11W@                     3                ---                  6

    Note: Operates when the transistor turns ON.                                          Note: Operates when the transistor turns ON.                               Note: Operate when the           contact turns ON.            Note: Operates when the transistor turns ON.

No-voltage Input Signal Levels

                    Short-circuit level (Transistor ON)                                                                                                                                                                                   Applicable Two-wire Sensor

                    • Residual voltage: 3 V max.                                                                                                                                                                                   • Leakage current: 1.5 mA max.

    No-contact      • Impedance when ON: 1 kΩ max.                                                                                                                                                                                 • Switching capacity: 5 mA min.

    input              (The leakage current is approx. 12 mA when the impedance is 0 Ω.)                                                                                                                                           • Residual voltage: 3 VDC max.

                    Open level (Transistor OFF)                                                                                                                                                                                    • Operating voltage: 10 VDC

                    • Impedance when OFF: 100 kΩ min.

    Contact in-     Use contacts which can adequately switch 5 mA at 10 V.

    put

Note: The DC voltage must be 30 VDC max.

Voltage Inputs (PNP Inputs)

No-contact Input (NPN Transistor)                                                                     No-contact Input (PNP Transistor)                                                                       Contact              Input

           Sensor,                                                                                                                     Sensor,

           etc.                                                                                                                        etc.

                                       0 V for inputs              Hold            Count                                                             0 V for inputs        Hold     Count                                                         0 V for inputs             Hold                Count

    H7CX-R11@          3                                  4    5    7       6                                                H7CX-R11@            3                  4  5    7   6                                                 H7CX-R11@   3                  4  5       7                6

    H7CX-R11W@         3                                       ---          6                                                H7CX-R11W@           3                     ---      6                                                 H7CX-R11W@  3                     ---                      6

    Note: Operate when the transistor turns OFF.                                                                            Note: Operate when the transistor turns ON.                                                            Note: Operate when the contact turns ON.

Voltage Input Signal Levels

    High level (Input ON): 4.5 to 30 VDC                                                  Note: 1.   The DC voltage must be 30 VDC max.

    Low level (Input OFF): 0 to 2 VDC                                                     2.         Input resistance: Approx. 4.7 kΩ

40
                                                                                                                                                                          H7CX-R@-N

Nomenclature

         Display Section                                                                                                                      Operation Keys

1.  Hold Indicator (orange)                                                                                                    7. Mode Key

    (Lit when the hold input or hold key is ON. )                                                                     5               (Used to switch mode and setting items.)

2.  Key Protect Indicator (orange)                             2                                                               8. Hold Key

    Lit when the key protect switch is ON.                     3                                                      6               (Used to sustain the measurement value and output.)

                                                               1

                                                                                                                      4

3.  Control Output Indicator (orange)                          7                                                               9. Up Keys        1 to          6

    OUT (1-output models)                                      8                                                      9

    OUT  1  2       (2-output models)

                                                                                                                                                         Switches

4.  Comparison Value 1, 2 Stage Indicator                                      6th digit        1st digit                      10. Key-protect Switch

5.  Present Value (Main Display)                                                                                               (Factory setting) OFF                  ON

    Character height: 10 mm (red)                                                                                                          (Disable)                  (Enable)

                                                               10                                                    11

6.  Comparison Value (Sub-display)

    Character height: 6 mm (green)

    Character Size        Character Size                                                                                       11. DIP Switch

    for Main Display      for Sub-display                                                                                             ON

            10 mm                      6 mm

                                                                                                                                      OFF     1  2       3     4  5   6     7   8

                                                                                                                                      (Factory setting)

Dimensions                                                                                                                                                                               (Unit: mm)

Tachometers

Dimensions without Flush Mounting Adapter                                                                                      Panel Cutouts

H7CX-R@-N                                                                                                                      Panel cutouts are as shown below

                                                                                                                               (according to DIN43700).

                                                                                                                                                                            60 min.

                                                                                                                                                                  45  +0.6

                                                                                                                                                                      −0

                             48 × 48               6                   63.7               14.4

                                                                                                                                                 45      +0.6

                                                                                                                                                         −0

                                                                                                                                                 15 min.

                                                                                                44.8 × 44.8                                60 min.

                                                                                                                               Note:  1.   The mounting panel thickness should be 1 to 5 mm.

                                                                                                                                      2.   To allow easier operation, it is recommended that

                                                                                                                                           Adapters be mounted so that the gap between

Dimensions with Flush Mounting Adapter                                         (Adapter and                                                sides with hooks is at least 15 mm (i.e., with the

                                                                                                                                           panel cutouts separated by at least 60 mm).

Waterproof Packing Ordered Separately)                                                                                                3.   It is possible to horizontally mount Timers side by

                                           Y92S-29 (order separately)                                                                      side. Attach the Flush Mounting Adapters so that

H7CX-R@-N                                  Waterproof Packing                                                                              the surfaces without hooks are on the sides of the

                                                                   Panel                                                                   Timers. If Counters/Tachometers are mounted side

                                                                               Y92F-30 (order separately)                                  by side, however, water resistance will be lost.

                                                                               Flush Mounting Adapter

                                                                                                             P3GA-11                             n side by side mounting

                                                                                                             (order

                                                                                                             separately)                                          A

                      58                              (51)                                                   Rear Surface                                A=(48n−2.5)        +1

                                                                                                             Connection                                                     −0

                                                                                                             Socket                           With Y92A-48F1 attached.

                                                                                                                                              A={48n−2.5+(n−1)×4}                    +1
                                                                                                                                                                                     −0

                                                                                                                                              With Y92A-48 attached.

                                                                                                                                              A=(51n−5.5)             +1
                                                                                                                                                                      −0
                                       48             7.5                      89.9

Dimensions          with  Front        Connecting Socket

H7CX-R@-N                                                              P2CF-11(-E) (order separately)

                                                                       Front Connecting Socket

                                                   H7CX-R@-N

                                                                       100.9                           *     These dimensions  vary with the kind of DIN track (reference value).

                                                                       103.2*

                                                                                                                                                                                                     41
H7CX-R@-N

Accessories (Order Separately)                                               Flush Mounting

    Note: Depending on the operating environment, the condition              Adapter                             Y92F-45

    of resin or rubber products may deteriorate, or they may                 Y92F-30                             Use this Adapter to install the

                                                                                                                 Counter/Tachometer in a cutout

    shrink or become harder. Therefore, it is recommended                    Order a Flush Mounting Adapter      previously made for a DIN 72 × 72 mm

    that resin products be replaced regularly.                               separately if the product is to be  device (panel cutout: 68 × 68 mm).

                                                                             flush-mounted.

Soft Cover

Y92A-48F1

                                                                             Waterproof Packing

                                                                             Y92S-29

Protecting the Timer in Environments Subject to Oil

    The H7CX's panel surface is water-resistive (conforming to IP@6,

    UL Type 4X) and so even if drops of water penetrate the gaps

    between the keys, there will be no adverse effect on internal circuits.

    If, however, there is a possibility of oil being present on the

    operator's hands, use the Soft Cover. The Soft Cover ensures             Order the Waterproof Packing separately if it is lost or damaged.

    protection equivalent to IP54 against oil. Do not, however, use the      The Waterproof Packing can be used to achieve protection equivalent

    H7CX in locations where it would come in direct contact with oil.        to IP66.

Hard Cover                                                                   (The Waterproof Packing will deteriorate, harden, and shrink

                                                                             depending on the application environment. To ensure maintaining the

Y92A-48                                                                      NEMA4 waterproof level, periodically replace the Waterproof

                                                                             Packing. The periodic replacement period will depend on the

                                                                             application environment. You must confirm the proper replacement

                                                                             period. Use 1 year or less as a guideline. If the Waterproof Packing is

                                                                             not replaced periodically, the waterproof level will not be maintained.)

                                                                             It is not necessary to mount the Waterproof Packing if waterproof

                                                                             construction is not required.

Connection Sockets

Refer to Connection Sockets on page page 13 for details.

Optional Products for Track Mounting

Refer to Optional Products for Track Mounting on page page 14 for details.

42
                                                                                                                                          H7CX-R@-N

Operating Procedures

Parameters must be set using both the DIP switch and the operation keys on the front panel.

Refer to the following for the detailed procedure.

Step1

Set the basic parameters.

                                                                     ON

                                                                     OFF    1  2  3  4   5  6  7   8

                                                                     (Factory  setting)

              Item                 OFF                          ON                          Pin 1     Pin 2  Input mode             Counting speed/

1      Input mode*1                                                                                                                minimum input signal width

       Counting speed/             Refer to the table on the right.                         OFF       OFF    Tachometer                   30 Hz

2      Minimum input signal width                                                           ON        OFF    AMD compatible               10 ms

3      Output mode*2                                                                        OFF       ON     Tachometer                   10 kHz*3

4                                  Refer to the table on the right.                         ON        ON     AMD compatible               1 ms

5      Average processing

6                                  Refer to the table on the right.                         Pin 6     Pin 4  Output mode

7             ---                  ---                          ---                         OFF       OFF    Upper and lower limit

8      NPN/PNP input mode          NPN                          PNP                         ON        OFF                 Area

Note:  The characters displayed in reverse video are the default settings.                  OFF       ON     Upper limit

                                                                                            ON        ON     Lower limit

The settings made using the DIP switch can be checked in the

DIP switch monitor mode.                                                                    Pin 5     Pin 6  Average processing

                                                                                            OFF       OFF    OFF (no average processing)

                                                                                            ON        OFF                 2 times

                                                                                            OFF       ON                  4 times

                                                                                            ON        ON                  8 times

*1. The setting of Pin 1 is disabled (OFF) for the H7CX-R11W@.

*2. For the H7CX-R11W@.

                     Item          OFF                          ON                             Pin 3         Output mode

3      Output 1 mode               Refer to the table on the right.                            OFF           Upper limit

4      Output 2 mode               Refer to the table on the right.                            ON            Lower limit

Note: The characters displayed in reverse video are the default settings.

*3. For the H7CX-R11W@, the counting speed will be 5 kHz even if 10 kHz                        Pin 4         Output mode

is selected.                                                                                   OFF           Upper limit

                                                                                               ON            Lower limit

                                                                                                                                                               43
H7CX-R@-N

    Step2                                                                 For details on operations in run mode, refer to page page 47.

    Change to Function               Setting Mode.

                                                                          *1         If the mode is switched to the function setting mode during operation, operation will

                           Power ON                                                  continue.

                                                                          *2         Changes made to settings in function setting mode are enabled for the first time when the

                                               3 s min.*1                            mode is changed to run mode.

                           Run mode                        Function                  Also, when settings are changed, the counter is reset (measured values initialized and

                                                        setting mode                 output turned OFF) on returning to run mode.

                                               3 s min.*2

                                                           The characters displayed in reverse video are the default settings.

                                     Decimal point         • Set the decimal point position using the U Key.

                                     position