电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

H7BX-AD1 AC24/DC12-24

器件型号:H7BX-AD1 AC24/DC12-24
器件类别:热门应用    机电/工控/自动化   
文件大小:28624.56KB,共28页
厂商名称:All Sensors
标准:
下载文档

器件描述

控制器 npn, retro, 4M, DC m12 conn. plastic

参数
制造商: Omron
产品种类: 控制器
RoHS:
显示器类型: LCD Backlight

H7BX-AD1 AC24/DC12-24器件文档内容

Multifunction Counter

H7BX

DIN 7272 mm Multifunction Counter with a Bright,

Easy-to-view, Negative Transmissive LCD.

Highly visible display with backlit transmissive LCD.
Selectable display color (red/green) enables checking output status at a

  distance.
Easy operation with a key for each digit.
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter, and

  tachometer (See note.).
Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-

  wire DC sensors.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only).

                                                                                    Be sure to read Safety Precautions on page 25.

Note: The functions that can be selected depend on the model.

Ordering Information

List of Models                            Output type              Supply voltage    1-stage    2-stage
                                                               100 to 240 VAC       H7BX-A     H7BX-AW
   External power supply       Contact and                     24 VAC/12 to 24 VDC  H7BX-AD1   H7BX-AWD1
                               NPN transistor output
              12 VDC

Accessories (Order Separately)

              Name                  Model
           Soft Cover          Y92A-72F1
          Hard Cover           Y92A-72
Terminal Cover (See note.)     Y92A-72T

Note: Supplied with the H7BX.

                                                                                    Multifunction Counter H7BX                      1
Specifications

Ratings

Item                        Model                               H7BX-A/AD1                                             H7BX-AW/AWD1

Type                                  Preset counter                                                Preset counter/tachometer

Supported configurations              1-stage preset counter, total and preset counter (See note    1-stage preset counter, 2-stage preset counter, total and
                                      1.) (selectable)                                              preset counter (See note 1.), batch counter, dual counter,
                                                                                                    tachometer (selectable)

            Power supply voltage       100 to 240 VAC (50/60 Hz)
            (See note 2.)             24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.)

Ratings Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)

            Power consumption         H7BX-A/AW: 9.6 VA max. (100 to 240 VAC)
                                      H7BX-AD1/AWD1: 8 VA max. (24 VAC), 5.3 W max. (12 to 24 VDC)

Mounting method                       Flush mounting

External connections                  Screw terminals

Degree of protection                  IP54 (front section only)

Input signals                         CP1, CP2, reset 1, reset 2, key protection

            Max. counting speed       30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2

            Input modes               Increment, decrement, command (UP/DOWN A), individual (UP/DOWN B), quadrature (UP/DOWN C)

Counter Output modes                  N, F, C, R, K-1, P, Q, A, K-2, D, L                           N, F, C, R, K-1, P, Q, A, K-2, D, L, H
                One-shot output time  0.01 to 99.99 s

            Reset input               External reset (minimum reset input signal width: 1 ms or 20 ms selectable), manual reset, and automatic reset (internal
                                      according to C, R, P, and Q mode operation)

            Pulse measurement                                      ---                              Periodic measurement (Sampling period: 200 ms)
            method

            Max. counting speed                                    ---                              30 Hz or 10 kHz (selectable)

            Measuring ranges                                       ---                              30 Hz: 0.01 to 30.00 Hz
                                                                                                    10 kHz: 0.01 Hz to 10 kHz
Tachom-     Measuring accuracy
eter        Output modes                                           ---                              0.1% FS 1 digit max. (at 23 5C)

                                                                   ---                              Upper and lower limits, area, upper limit, lower limit

            Auto-zero time                                         ---                              0.1 to 99.9 s

            Startup time                                           ---                              0.0 to 99.9 s

            Average processing                                     ---                              OFF/2/4/8 times

Prescaling function                   Yes (0.001 to 99.999)

Decimal point adjustment              Yes (rightmost 3 digits)

Sensor waiting time                   290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)

Key protection input                  Response speed: Approx. 1 s
                                      No-voltage NPN input (fixed)
                                      Short-circuit (ON) impedance: 1 k max. (Leakage current at 0 : Approx. 12 mA)
                                      Short-circuit (ON) residual voltage: 3 V max.
                                      Open (OFF) impedance: 100 k min.

Input method                          No-voltage NPN input or voltage PNP input (selectable)
(except key protection input)         No-voltage input
                                      Short-circuit (ON) impedance: 1 k max. (Leakage current at 0 : Approx. 12 mA)
                                      Short-circuit (ON) residual voltage: 3 V max.
                                      Open (OFF) impedance: 100 k min.
                                      Voltage input
                                      High level: 4.5 to 30 VDC
                                      Low level: 0 to 2 VDC
                                      Input resistance: Approx. 4.7 k

External power supply                 12 VDC (10%), 100 mA (For details, refer to External Power Supply on page 26.)

Control output                        Contact output: 3 A at 250 VDC/30 VDC, resistive load (cos = 1)
                                      Minimum applied load: 10 mA at 5 VDC (Failure level: P, reference value)
                                      Transistor output: 100 mA max. at 30 VDC max.
                                      Residual voltage: 1.5 VDC max. (approx. 1 V)
                                      Leakage current: 0.1 mA max.

Display (See note 3.)                 Backlit 7-segment negative transmissive LCD
                                      Character Heights
                                      PV: 13.5 mm (red/green)
                                      SV: 9 mm (green)

Digits                                6 digits                                                      6 digits
                                      -99,999 to 999,999 (5 digits negative and 6 digits positive)  Counter: -99,999 to 999,999 (5 digits negative and 6 digits
                                                                                                    positive)
                                                                                                    Tachometer: 0 to 999,999 (6 digits)

Memory backup                         EEPROM (Overwrites: 100,000 min.), Data storage: 10 years min.

Ambient operating temperature         -10 to 55C (with no icing)

Ambient storage temperature           -25 to 65C (with no icing)

Ambient operating humidity            25 to 85C (with no condensation)

Case color                            Black (N1.5)

Accessories                           Two flush-mounting adapters, terminal cover                   Two flush-mounting adapters, terminal cover, DIP switch
                                                                                                    setting stickers

Note 1. The total and preset counter functions as a 1-stage preset counter and total counter.
       2. Do not use an inverter output for the power supply.
       3. Displayed only when the power is ON. Not displayed when the power is OFF.

2              Multifunction Counter H7BX
Characteristics

Insulation resis- 100 M min. (at 500 VDC) between current-carrying terminal and exposed non-                  Electrical Life Expectancy
                                                                                                               (Reference Values)
tance              current-carrying metal parts, and between non-continuous contacts                           Resistive Load

Dielectric         Between current-carrying metal parts and non-current-carrying metal parts:                          1,000No. of operations (103)
strength           2,000 VAC, 50/60 Hz for 1 min
                   Between power supply and input circuit: 2,000 VAC, 50/60 Hz for 1 min (for models                    700
                   other than the H7BX-A@D1)
                   1,000 VAC, 50/60 Hz for 1 min (H7BX-A@D1)                                                            500
                   Between control output, power supply, and input circuit: 2,000 VAC, 50/60 Hz for 1 min
                   Between non-continuous contacts: 1,000 VAC, 50/60 Hz for 1 min                                       300
                                                                                                                                                          30 VDC (cos=1)
Impulse with-      Between power terminals: 3.0 kV (1.0 kV for 24 VAC/12 to 24 VDC models)
stand voltage      Between current-carrying terminal and exposed non-current-carrying metal parts:
                   4.5 kV (1.5 kV for 24 VAC/12 to 24 VDC models)

                         Between power terminals: 1.5 kV                                                                              100     250 VAC (cos=1)
Noise immunity Between input terminals: 600 V
                                                                                                                                        70
                         Square-wave noise by noise simulator (Pulse width: 100 ns/1 s, 1-ns rise)                                     50

Static immunity    Malfunction: 8 kV                                                                                                        0
                   Destruction: 15 kV

                   Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 4 cycles each in 3 directions (8                                     1                     2                 3  4
                   min/cycle)
Vibration resis-   Malfunction: 10 to 55 Hz, 0.50-mm single amplitude for 4 cycles each in 3 directions (8                                                                             Load current (A)
tance              min/cycle)
                                                                                                                                     Inductive Load
Shock resis-       Destruction: 294 m/s2 3 times each in 6 directions                                        No. of operations (103)
tance              Malfunction: 98 m/s2 3 times each in 6 directions                                                                     1,000
                                                                                                                                          700
                         Mechanical: 10,000,000 operations min.                                                                           500
Life expectancy Electrical: 100,000 operations min. (3 A at 250 VAC/30 VDC, resistive load) (See
                                                                                                                                       300
                         note.)                                                                                                                                     30 VDC (L/R=7 ms)

Weight             Approx. 250 g

Note: Check the electrical life expectancy curve.

Applicable Standards                                                                                                                  100
                                                                                                                                                  250 VAC (cos=0.4)

Approved cURus: UL 508, CSA C22.2 No. 14                                                                                               70

safety      EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II;

standards EN 61326; VDE 0106 Part 100                                                                                                  50

                                                                                                                                           0   1                     2                 3  4

            (EMI)                                  EN 61326                                                                                                                      Load current (A)

            Emission Enclosure:                    EN 55011 Group 1 class A                                  A current of 0.15 A max. can be switched at
                                                                                                             125 VDC (cos = 1) and current of 0.1 A max. can
            Emission AC mains:                     EN 55011 Group 1 class A                                  be switched with L/R = 7 m/s. In both cases, a life of
                                                                                                             100,000 operations can be expected.
            (EMS)                                  EN 61326

            Immunity ESD:                          EN 61000-4-2: 4 kV contact discharge;

                                                             8 kV air discharge

            Immunity RF-interference:              EN 61000-4-3:10 V/m (Amplitude-modulated,

                                                             80 MHz to 1 GHz);

EMC                                                          10 V/m (Pulse-modulated,

                                                             900 MHz 5 MHz)

            Immunity Conducted Disturbance: EN 61000-4-6: 3 V (0.15 to 80 MHz)

            Immunity Burst:                        EN 61000-4-4: 2 kV power-line;

                                                             1 kV I/O signal-line

            Immunity Surge:                        EN 61000-4-5: 1 kV line to lines (power and output lines

                                                             (relay outputs));

                                                             2 kV line to ground (power and output lines

                                                             (relay outputs))

            Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)

                                                                                                     Multifunction Counter H7BX                                                           3
I/O Functions                                                                                                     Using as a Tachometer

Using as a Counter (See note 1.)

                        (1) All Modes Except for Dual Counter Mode                                                         CP1,      Reads counting signals.
                         Reads count signals.                                                                             CP2       (CP2 input is not
                         Increment, decrement, up/down (command, individual, or quadrature) inputs                                  available.)

   CP1, CP2                can be used.                                                                                              Holds the measurement
                        (2) Dual Counter Mode                                                                                          value and outputs.
                         Reads CP1 count signals on CP1 input and CP2 count signals on CP2 input.                Inputs               (Reset 2 input is not
                         Increment signals can be used.                                                                               available.)
                                                                                                                           Reset 1,
                                                                                                                           Reset 2    The reset indicator is lit
                                                                                                                                       during hold.
Inputs                  (1) All Modes Except for Dual Counter Mode
                         Resets present value and outputs (OUT2 when using the batch counter). (See              Outputs  OUT1, 2   Outputs signals according
              Reset or                                                                                                               to the specified output
              Reset 1      note 2.)                                                                                                  mode when a set value is
                         Counting cannot be performed while resetting or when reset 1 input is ON.                                  reached.
                         The reset indicator is lit while the reset input is ON.
                        (2) Dual Counter Mode                                                                      Using as a Counter or
                         Resets the CP1 present value to 0.                                                        Tachometer
                         Counting the CP1 input cannot be performed while the reset 1 input is ON.
                         The reset indicator is lit while the reset 1 input is ON.

   Total Reset          The reset operation depends on the selected function. (See note 3.)
   or Reset 2
                                                                                                                                     Prohibits using the keys
Outputs OUT1, 2         When the corresponding set value is reached, signals are output according to the          Key protection       on the front panel.
                        designated output mode.                                                                   input
                                                                                                                                     Set the key protection
Note 1. Refer to pages 14 to 17 for information on the operation of input and output functions.                                        level in function selection
       2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement                                  mode.
           mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with
           2-stage models.                                                                                        Note: For details, refer to page 24.
       3. The reset indicator will not be lit when the total reset or reset 2 input is ON.

   Function                        Reset operation

   1-stage/2-stage preset counter Does not operate (Not used).

   Total and preset counter   Resets the total count value.
                              Holds the total count value at 0 while the total reset input is ON.

   Batch counter             Resets the batch count value and batch output (OUT1).
                              Holds the batch count value at 0 while the reset 2 input is ON.

   Dual counter               Resets the CP2 present value.
                              Counting for CP2 input is disabled while the reset 2 input is ON.

4  Multifunction Counter H7BX
Connections

Terminal Arrangement

Confirm that the power supply meets specifications before using the H7BX.

H7BX-A                                                                                    H7BX-AW

                               0V  Reset 1                                                                              0V   Reset 1
                                         CP2                                                                                       CP2
                                               CP1                                                                                        CP1

                                                     Reset 2                                                                                   Reset 2
                                                          12 VDC                                                                                      12 VDC
                                                                 Output COM                                                                                 Output COM

                               8 9 10 11 12 13 14                                                                       8 9 10 11 12 13 14

                                (-) External power supply (+)                                                           (-)  External power supply  (+)
               Unused. 15                                                                               Unused. 15                                  OUT1 17
                                                                              17 Unused.

               Key         16       OUT           OUT                                                   Key         16                              OUT2
               protection                                  18                                           protection                                             18

                                                                                                                                 OUT2 OUT1

                               1234567                                                                                  1234567

                                         Unused.                                                                                                             Unused.
                                               Unused.
                                                     Unused.

H7BX-AD1                                                                                  H7BX-AWD1

                               0V  Reset 1                                                                              0V   Reset 1
                                         CP2                                                                                       CP2
                                               CP1                                                                                       CP1

                                                     Reset 2                                                                                   Reset 2
                                                            12 VDC                                                                                    12 VDC
                                                                  Output COM                                                                                Output COM

                               8 9 10 11 12 13 14                                                                       8 9 10 11 12 13 14

                               (-) External power supply (+)                                                            (-)  External power supply  (+)
               Unused. 15                                                                               Unused. 15                                  OUT1 17
                                                                              17 Unused.

               Key         16       OUT           OUT                                                   Key         16                              OUT2
               protection                                  18                                           protection                                             18

                                                                                                                                 OUT2 OUT1

                               1234567                                                                                  1234567

                                         Unused.                                                                                                    Unused.
                                               Unused.
                                                     Unused.

                                                 (-) (+)                                                                (-) (+)

Note: Do not use the unused terminals for relay connections.                               Input Circuits

Block Diagram                                                                             CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input

                (Basic insulation)  Power supply
                                         circuit
Output circuit                                                                                       +14 V

(Basic insulation)                                                                                 1 k

                Internal control    Display circuit                                       IN            Internal                 Note: The circuit shown above is for
                      circuit                                                                           circuit                          no-voltage input (NPN input).
Input circuit                         Key switch
                                         circuit

                                                                                                     Multifunction Counter H7BX                                         5
Input Connections

A no-voltage input (short-circuit or open) or voltage input can be selected for each input. (The key protection input is always a no-voltage

input (NPN input)).

No-voltage Inputs (NPN Inputs)

Open Collector                          Voltage Output                          Contact Input                        DC Two-wire Sensor

PLC                                                 Sensor
or sensor

            0-V input
                   Reset/reset 1 input

                           CP2 input
                                  CP1 input
                                          Total reset/reset 2 input
                                                 Key protection input
                                                                               0-V input
                                                                                       Reset/reset 1 input
                                                                                               CP2 input
                                                                                                      CP1 input
                                                                                                              Total reset/reset 2 input
                                                                                                                     Key protection input
                                                                                                                                                    0-V input
                                                                                                                                                           Reset/reset 1 input
                                                                                                                                                                   CP2 input
                                                                                                                                                                          CP1 input
                                                                                                                                                                                  Total reset/reset 2 input
                                                                                                                                                                                          Key protection input
                                                                                                                                                                                                                        0-V input
                                                                                                                                                                                                                                Reset/reset 1 input
                                                                                                                                                                                                                                       CP2 input
                                                                                                                                                                                                                                               CP1 input
                                                                                                                                                                                                                                                      Total reset/reset 2 input
                                                                                                                                                                                                                                                              Key protection input

Terminal No. 8 9 10 11 12 16            Terminal No. 8 9 10 11 12 16            Terminal No. 8 9 10 11 12 16          Terminal No. 8 9 10 11 12 16
Operates when the transistor turns ON.  Operates when the transistor turns ON.  Operates when the contact turns ON.  Operates when the transistor turns ON.

Note: When the H7BX is used as a tachometer, the CP2 input and total reset/reset 2 input are not used.

No-voltage Input Signal Levels                                                                                                 Applicable Two-wire Sensors
                                                                                                                            Leakage current: 1.5 mA max.
No-contact  Short-circuit level                                                                                             Switching capacity: 5 mA min.
input       Transistor ON                                                                                                   Residual voltage: 3 VDC max.
             Residual voltage: 3 V max.                                                                                    Operating voltage: 10 VDC
             Impedance when ON: 1 k max.
            (The leakage current is 5 to 12 mA when the impedance is 0 .)                               Contact Input

            Open level
            Transistor OFF
             Impedance when OFF: 100 k min.

Contact input Use contact which can adequately switch 5 mA at 10 V.

Note: Use a DC power supply of 30 V max.

Voltage Inputs (PNP Inputs)                                No-contact Input (PNP Transistor)
No-contact Input (NPN Transistor)

           Sensor                                           Sensor

                   0-V input
                          Reset/reset 1 input

                                  CP2 input
                                         CP1 input
                                                 Total reset/reset 2 input

                                                                                                              0-V input
                                                                                                                     Reset/reset 1 input

                                                                                                                             CP2 input
                                                                                                                                    CP1 input
                                                                                                                                            Total reset/reset 2 input
                                                                                                                                                                                                         0-V input
                                                                                                                                                                                                                 Reset/reset 1 input
                                                                                                                                                                                                                        CP2 input
                                                                                                                                                                                                                                CP1 input
                                                                                                                                                                                                                                        Total reset/reset 2 input

            Terminal No. 8 9 10 11 12                       Terminal No. 8 9 10 11 12                                Terminal No. 8 9 10 11 12
           Operates when the transistor turns OFF.          Operates when the transistor turns ON.                   Operates when the contact turns ON.

Note: When the H7BX is used as a tachometer, the CP2 input and total reset/reset 2 input are not used.

Voltage Input Signal Levels

High level (Input ON): 4.5 to 30 VDC
Low level (Input OFF): 0 to 2 VDC
Note 1. Use a DC power supply of 30 V max.

       2. Input resistance: Approx. 4.7 k

6           Multifunction Counter H7BX
Nomenclature

             Indicators                                                                                                                                      Operation Keys
                                                                                                                                             I Mode Key
A Reset Indicator (Orange)                                A
                                                                                                                                                 Used to switch mode and setting items.
                                                          B                                                                               D
                                                                                                                                          E  J Reset Key
Lit when the reset input (1) or reset key is ON.          C                                                                               K  K Up Keys: 1 to 6
                                                                                                                                          I
B Key Protection Indicator (Orange)                       F                                                                                                       Switches
                                                          G                                                                       L          L DIP Switch

C Control Output Indicator (Orange)                       H                                                                                                     12345678
                                                                                                                                              ON
OUT:         One stage
                                                                                                                                             OFF
OUT1, OUT2: Two stages                                    J

D Present Value (Main Display)

    Character height: 13.5 mm (Red/green selectable)

E Set Value (Sub-display)                                       X CHXINXAX                 X  No. X
                                                                                          IN  MADE
    Character height: 9 mm (Green)
                                                                                                     Lot  OMRON Corporation

                                                                                          COUNTER H7BX-A

F Total Count Indicator (Green)

    Lit when the total count value is displayed.

G Batch Indicator (Green)

    Lit when the batch count value is displayed.

H Set Value 1 and 2 Stage Indicators (Green)

Dimensions                                                                                                                                                                               (Unit: mm)

Counter

Counter
H7BX-A@@

                                                             6                                                                               M3.5 terminal screw

                                                      72                                                                     100             (effective length: 6 mm)

                            72                                                                                                               67.6 67.6

                                                                                                                                                                       Note: M3.5 terminal screws
                                                                                                                                                                               (effective length: 6 mm).

Dimensions with Flush Mounting Adapter                                                                                                                                Panel Cutouts
H7BX-A@@
(The flush mounting adapter is supplied with the H7BX.)                                                                                      M3.5 terminal screw       Panel cutouts are as shown below
                                                                                                                                             (effective length: 6 mm)
                                                                                      72                                                                               (according to DIN 43700).

                                                           72                                                                                                                                      100 min.
                                                                                                                                                                                         68+-00.7

                                                                                                                                             69 69                           68+-00.7
                                                                                                                                                                       82 min.

                                                                Panel

                                                             6                                                               102

                                                                                                                                             5 + panel thickness       Note: The mounting panel thickness
                                                                                                                                                                               must be 1 to 5 mm.

Accessories (Order Separately)

Soft Cover                                                                                                                        Hard                                 Terminal Cover (See note.)
                                                                                                                                     Cover                             Y92A-72T
Y92A-72F1                                             Product Protection for Use in
                                                      Environments Subject to Water or Oil                                        Y92A-72                              (VDE0106/T100)

Note: Depending on the operating environment,         The panel surface has a protective                                                                                                 Note: Supplied with the
        the condition of resin parts may              structure so that the internal circuits will                                                                                               H7BX.
        deteriorate, and may shrink or harden.        not be adversely affected if drops of water
        Therefore, it is recommended that resin       penetrate the gaps between the keys. If,
        parts are replaced regularly.                 however, there is a possibility of water or
                                                      oil being present on the operator's hands,
                                                      mount the optional Soft Cover.
                                                      The Soft Cover ensures protection
                                                      equivalent to IP54. Do not, however, use
                                                      the H7BX in locations where it would come
                                                      into direct contact with oil.

                                                                                                                                  Multifunction Counter H7BX                                                      7
Operating Procedures

Setting Procedure Guide
   Settings for Counter Operation
   (1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter)

    Using Basic Settings Only                      The settings can be made             12345678
   Basic Settings                                  easily with the DIP switch.
                                                                                   ON
    Counting speed (30 Hz, 5 kHz)                     For details on the setting  OFF
    Input mode (UP, DOWN)                         methods, refer to page 9.
    Output mode (N, F, C, K-1)
    One-shot output time (0.5 s, 0.05 s)
    Reset input signal width (20 ms, 1 ms)
    NPN/PNP input mode (NPN, PNP)

    Using Input Modes Not Given Above (Up/Down A,   Performing Advanced Settings: Dual Count Calculating
      Up/Down B, Up/Down C) , Output Modes            Mode, Output 1 Time, Decimal Point Position, Prescale
      (R/P/Q/A/K-2/D/L/H), or (OUT2) Output Time      Value, Display Color, or Key Protect Level

      Set all functions with the operation keys.      Settings other than the basic functions above
          For details on the setting methods,         can be performed with the operation keys.

      refer to page 10.                                   For details on the setting methods,
                                                      refer to page 10.

Note: The default setting is for a 1-stage preset counter. (For models with a 2-stage setting, the default is a 2-stage preset counter.)

Setting for Tachometer Operation (H7BX-AW@ only)

    Using Basic Settings Only                      The settings can be made             12345678
   Basic Settings                                  easily with the DIP switch.
                                                                                   ON
    Counting speed (30 Hz, 10 kHz)                    For details on the setting  OFF
    Output mode (HI-LO, AREA, HI-HI, LO-LO)       methods, refer to page 19.
    Average processing (OFF, 2, 4, 8 times)
    NPN/PNP input mode (NPN, PNP)

   Performing Advanced Settings: Decimal Point Position, Prescale Value, Auto-zero Time, Startup Time,
      Display Color, or Key Protect Level

      Settings other than the basic functions above can be
      performed with the operation keys.

          For details on the setting methods, refer to page 20.

Note: The default setting is for a 2-stage preset counter.

8  Multifunction Counter H7BX
Operating Procedures (Counter Function)
Settings for Basic Operations

                            Settings for basic functions can be performed with just the DIP switch.

                                                                                       Be sure to turn ON pin 1 when using the DIP switch.
                            X CHXINXAX   X  No. X
                                        IN  MADE

                                                   Lot  OMRON Corporation

                            COUNTER H7BX-A

                                                                                                            12345678

                                                                                  ON
                                                                                  OFF

                   Item                                                    OFF                        ON

1 DIP switch settings enable/disable                    Disabled                       Enabled                                           Pin 4        Pin 5                           Output mode
                                                                                                                                         OFF          OFF                                     N
2 Counting speed                                                           30 Hz                      5 kHz                               ON          OFF                                     F
                                                                                                                                         OFF           ON                                     C
3 Input mode                                            UP (increment) DOWN (decrement)                                                   ON           ON                                    K-1

4                                                       Refer to the table on the right.
      Output mode

5

6 One-shot output time (See note.)                                         0.5 s                      0.05 s

7 Reset input signal width                                                 20 ms                      1 ms

8 NPN/PNP input mode                                    NPN (no-voltage) PNP (voltage)

Note: All the pins are factory-set to OFF.

The ON/OFF status of the DIP switch pins                                          CoFnuvnecntiieonnt
can be confirmed using the front display.
For details, refer to page 23.

Caution             Always turn OFF the power supply before changing the DIP switch settings.
                   Always turn ON pin 1 when performing settings with the DIP switch. Performing settings with the DIP switch is

                     disabled when pin 1 is OFF.
                   DIP switch setting changes will be updated when the power is turned ON. Perform the settings before performing

                     installation and supplying power.
                   Properly set the DIP switch to match the item being counted (or measured) and use the DIP switch monitor for

                     confirmation.
                   Use the keys on the front panel to perform all settings for input modes, output modes, and output times that cannot

                     be set with the DIP switch. For details on the setting methods, refer to page 10.
                     When performing these settings, always turn OFF pin 1(DIP switch setting) (disabled).

                   Using the H7BX as a Total and Preset Counter, Batch Counter, or Dual Counter

The default setting is for a 1-stage preset                                       Configuration selection mode                                        Power ON
counter. (For models with a 2-stage setting,                                                                                                          Run mode
the default is for a 2-stage preset counter.)
To make changes, use the procedure shown
on the right. For details, refer to page 23.

                                                                                  Configuration                                Key + Up 1 Key for at
                                                                                  selection                             least 1 s (See note.)

Hold down the Key and press the Up 1 Key                                          Select the configuration using the Up Key. (The configurations that can be selected depend on the model.)
for at least 1 s.
The mode will not change if the Up 1 Key is                                       (1-stage preset (2-stage preset (Total and             (Batch counter) (Dual counter) (Tachometer)
pressed first.

                                                                                  counter)                    counter)  preset counter)

Note: This includes using a model with a 2-stage
        setting as a 1-stage preset counter.

After setting the DIP switch for basic operations, advanced functions (see note) can be added using the operation keys. For details,
refer to page 10.

Note: Advanced functions consist of dual count calculating mode, output 1 time, decimal point position, prescale value,
display color, and key protect level.

                                                                                                                              Multifunction Counter H7BX                                           9
When using the H7BX as a Total and Preset Counter, Batch Counter, or Dual Counter, switch the configuration using the procedure on page 23.

Setting Advanced Functions
           Settings that cannot be performed with the DIP switch are performed with the operation keys.

                    Power ON

    Run mode                                           For details on operations and display in run mode, refer to page 12. The display depends on the configuration used.

                           See note 1.   See note 2.   Note: 1. If the mode is switched to the function setting mode during operation, operation will continue.
                               3 s min.  3 s min.              2. Changes made to settings in function setting mode are enabled for the first time when the
                                                                  mode is changed to run mode. Also, when settings are changed, the counter is reset (present
                                                                  value initialized and output turned OFF) on returning to run mode.

                                                       The characters displayed in reverse video are the default settings.
                                                       When performing settings with operation keys only, turn OFF pin 1 of the DIP switch (factory setting).
                                                       If pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed.

                                          See note 3.   Set the input mode with any of the Up Keys.                                                          Note 3: When using as a dual counter

                                         Input mode         See note 5. See note 5.                                                                                                     Dual count
                                         (CNTM)                                                                                                                                         calculating mode
                                                                (UP) (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C)                                                                         (ADD)
                                                          Note 5: Displayed for output modes other than K-2, D, L, and H only.
                                                                                                                                                                Set the dual count calculating mode
                                                                                                                                                                  the Up Key.

                                                                                                                                                                                      See note 4.

                                         Output mode Set the output mode with any of the Up Keys.          See note 6. See note 6. See note 6. See note 6.  (Addition)(Subtraction)
                                         (OUTM)
                                                                                                                                                                Note 4: Displayed only when
                                                                                                                                                                           the output mode is
                                                                                                                                                                           K-2, D, L, or H.

                                                       (N) (F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H)

                                         See note 7.      Note 6: For models with a 2-stage setting, the input mode is          Note 7: Set the number for each digit with the Up Keys.
                                                                     displayed only when an Up/Down Mode is selected.             2-stage Preset Counter
                                         Output time
                                         (OTIM)         Set the number for each digit with the Up Keys.

                                                                                                                                                Output 2          (0.01 s) (0.50 s) (99.99 s)
                                                                                                                                                time
                                                                                                                                                (OTM2)        Note: Displayed only when the
                                                                                                                                                                      output mode is C, R, K-1,
                                                             (0.01 s) (0.50 s) (99.99 s)                                                                              P, Q, A, or K-2.
                                                          Note: Displayed only when the output mode is C, R, K-1, P,
                                         Counting                                                                                               Output 1       (Outputs held) (0.01 s) (99.99 s)
                                         speed                     Q, A, or K-2.                                                                time
                                                       Set the counting speed with any of the Up Keys.                                        (OTM1)        If the output time is 0.00,
                                         (CNTS)                                                                                                               hold is displayed.
                                                               (30 Hz) (5 kHz)
                                                                                                                                                              Note 1: Displayed for output
    Function setting mode                Min. reset    Set the min. reset input signal width with any of the Up Keys.          Batch Counter                           modes other than D, L,
                                         period                                                                                                                          and H.
                                                               (20 ms) (1 ms)
                                         (IFLT)                                                                                                               Note 2: HOLD cannot be set
                                                                                                                                                                         when the output mode
                                                                                                                                                                         is K-2.

                                                                                                                                                Output 2         (0.01 s)(0.50 s)(99.99 s)
                                                                                                                                                time
                                                                                                                                                (OTM2)        Note: Displayed only when the
                                                                                                                                                                      output mode is C, R,
                                         Decimal point Set the decimal point position with any of the Up Keys.                                                      K-1, P, Q, A, or K-2.
                                         position

                                         (DP)

                                                       No decimal One digit after Two digits after Three digits after

                                                       point   decimal point decimal point decimal point

                                         Prescale       Set the number for each digit with the Up Keys.
                                         value
                                                               (0.001) (1.000) (99.999)
                                         (PSCL)

                                         NPN/PNP       Set the NPN/PNP input mode with any of the Up Keys.
                                         input mode
                                         (IMOD)

                                                       (NPN    (PNP
                                                       input)  input)

                                         Display       Set the display color with any of the Up Keys.
                                         color
                                         (COLR)                (Red) (Green) (Red- (Green-
                                                                                          green) red)

                                         Key            Set the key protect level with any of the Up Keys.
                                         Protection
                                         Level                  (KP-1) (KP-2) (KP-3) (KP-4) (KP-5)

                                         (KYPT)

10                         Multifunction Counter H7BX
Explanation of Functions

Settings marked with a star can be performed with the DIP switch.

Input Mode (cntm)                                                 Reset Input Signal Width (iflt)
Set increment mode (UP), decrement mode (DOWN), or one of           Set the reset input signal width (20 ms/1 ms) for reset/reset 1
the increment/decrement modes (UP/DOWN A, UP/DOWN B, or             and total reset/reset 2 inputs together. If contacts are used for
UP/DOWN C) as the input mode. Input modes other than UP or          input signals, set the counting speed to 20 ms. Processing to
DOWN modes cannot be set using the DIP switch. Use the              eliminate chattering is performed for this setting.
operation keys if other modes are required. (For details on the
operation of the input modes, refer to Input Modes and Present       Decimal Point Position (dp)
Value on page 13.)                                                  Decide the decimal point position for the present value, CP1/
                                                                    CP2 present values, set values (SV1, SV2), total count value,
Dual Count Calculating Mode (calm)                                dual count value and dual count set value.
When the H7BX using as a dual counter, select either ADD
(addition) or SUB (subtraction) as the calculation method for the    Prescale Value (pscl)
dual count value.                                                   Pulses input to the counter are converted according to the
                                                                    specified prescale value.
   ADD: Dual count value = CP1 PV + CP2 PV                          Setting range: 0.001 to 99.999
   SUB: Dual count value = CP1 PV - CP2 PV                          Example: To display the feed distance for systems that output

Output Mode (outm)                                                       25 pulses for a feed length of 0.5 m in the form @@.@@ m:
Set the way that control output for the present value is output.           1. Set the decimal point position to 2 decimal places.
The possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and         2. Set the prescale value to 0.02 (0.5 25).
H. Output modes other than N, F, C, or K-1 cannot be set using
the DIP switch. Use the operation keys if other modes are                    0.5 m
required. The output modes that can be set vary with the model.
(For details on the operation of the output modes, refer to Input/
Output Mode Settings on page 14.)

One-shot Output Time (otim)                                                                                  25 pulses
Set the one-shot output time (0.01 to 99.99 s) for the control
output. A one-shot output can be used only when C, R, K-1, P,            Encoder
Q, A, or K-2 is selected as the output mode. Output times other
than 0.5 s or 0.05 s cannot be set with the DIP switch. Use the     Note: Incorrectly setting the prescale value will result in
operation keys if other settings are required.                              counting errors. Check that the setting has been
                                                                            performed correctly before using the H7BX.
One-shot Output 2 Time (otm2)
When the H7BX using as a 2-stage counter or batch counter, set       NPN/PNP Input Mode (imod)
the one-shot output time (0.01 to 99.99 s) for control output
(OUT2). A one-shot output can be used only when C, R, K-1, P,       Select either NPN input (no-voltage input) or PNP input (voltage
Q, A, or K-2 is selected as the output mode. Output times other     input) as the input format. For 2-wire sensors, set the format to
than 0.5 s or 0.05 s cannot be set with the DIP switch. Use the     NPN input. The same format setting applies to all external inputs.
operation keys if other settings are required.                      For information on input connections, refer to page 6.

One-shot Output 1 Time (otm1)                                     Display Color (colr)
When the H7BX using as a 2-stage counter, set the one-shot          Set the color used for the present value.
output time (0.01 to 99.99 s) for control output (OUT1). A one-
shot output can be used only when D, L, or H is selected as the          Output OFF (See note.) Output ON (See note.)
output mode. If the output time is set to 0.00, hold is displayed,
and outputs are held.                                               red           Red (fixed)

Counting Speed (cnts)                                             grn           Green (fixed)
Set the maximum counting speed (30 Hz/5 kHz) for CP1 and
CP2 inputs together. If contacts are used for input signals, set    r-g  Red                                              Green
the counting speed to 30 Hz. Processing to eliminate chattering
is performed for this setting.                                      g-r  Green                                            Red

                                                                    Note: When the H7BX using as a 2-stage counter, this is the status of output 2.

                                                                     Key Protect Level (kypt)
                                                                    Set the key protect level.
                                                                    For details, refer to Key Protect Level on page 24.

                                                                         Multifunction Counter H7BX                              11
Operation in Run Mode

    Set the number for each digit with the Up Keys.

1-stage Counter           Present value       Present Value
2-stage Counter           Set value            Shows the present count value.

                           Present value       Set Value (Set Value 1, Set Value 2)
                           Set value 1          Set the set value.
                                                When the present value reaches the set
                                                value, signals are output according to the
                                                specified output mode.

                           Present value
                           Set value 2

Total and Preset Counter

                           Present value       Present Value/Set Value
                           Set value            Same as 1-stage counter.

                                              Total Count Value
                                                Shows the present total count value.

                           Total count value

Batch Counter             Present value       Present Value/Set Value
Dual Counter              Set value            Same as 1-stage counter.

                           Batch count value   Batch Count Value
                           Batch count set      Shows the number of times the count has
                           value                been completed for the present value.

                                              Batch Count Set Value
                                                Set the batch count set value. When the
                                                batch count value reaches the batch
                                                count set value, batch output (OUT1)
                                                turns ON.

                           Dual count value    Dual Count Value
                                                Shows the sum of the CP1 present value and CP2 present value when the dual count
                           Dual count set       calculating mode is ADD and shows the value obtained by subtracting the CP2 present
                           value                value from the CP1 present value when the dual count calculating mode is SUB.

                                              Dual Count Set Value

                           CP1 present value Set the dual count set value. When the dual count value reaches the dual count
                                                    set value, signals are output according to the specified output mode.

                           CP2 present value

                                                   CP1/CP2 Present Value

                                                      Show the present count values for CP1 and CP2 present values respectively.

12  Multifunction Counter H7BX
Input Modes and Present Value (See note 1.)

                                       UP (Increment) Mode                                                                        DOWN (Decrement) Mode
CP1: Count input; CP2: Prohibit input                                                          CP1: Count input; CP2: Prohibit input

         H                                         A                  A                                 H                                   A                 A
CP1                                                                                            CP1                                             Prohibit
                                                      Prohibit                                                                                                  n-4
         L                                                                                              L                                      n-3                           n-5

         H                                                                                              H
CP2                                                                                            CP2

         L                                                                                              L
                                                                                                             n
                                                                                         5
                                                                                                                     n-1
Present                                                                            4
value                                                 3                                                                          n-2
                                                                                               Present
                                    2                                                          value

               1

                         0                                                                                        0
                  0
                                                                                               A must be greater than the minimum signal width. (See note 2.)
A must be greater than the minimum signal width. (See note 2.)
                                                                                               CP1: Prohibit input; CP2: Present value
CP1: Prohibit input; CP2: Count input

         H                                   A                     A                                    H                                A                 A
CP1                                                                                            CP1
                                                Prohibit                                                                                    Prohibit
         L                                                                                              L
(See note 3.)                                                                                  (See note 3.)

         H                                                                                              H
CP2                                                                                            CP2

         L                                                                                              L
                                                                                                                n
                                                                                            5
                                                                                                                           n-1
Present                                                                          4                                                          n-2
value                                                                 3                        Present                                                                    n-3
                                                                                               value                                                                                  n-4
                                                                                                                                                                                                n-5
                                                2

                  1

                          0                                                                                      0
                  0
                                                                                               A must be greater than the minimum signal width. (See note 2.)
A must be greater than the minimum signal width. (See note 2.)

               UP/DOWN A: Command Input Mode                                                                  UP/DOWN B: Individual Input Mode

         H                                         A                  A                                 H
CP1                                                                                            CP1

         L                                                                                              L

         H                                                                                              H
CP2                                                                                            CP2

         L                                                                                              L

                                          3                                          3                                                3                          3
                                                                         2
Present                 2                             2                                        Present                          2           2                 2
value                                                                                          value

               1                                                1                                          1                                          1    1

     0                                                                                         00
0

A must be greater than the minimum signal width. (See note 2.)

               UP/DOWN C: Quadrature Input Mode                                                Note 1. If the configuration is set to dual counter, CP1 and CP2 inputs will operate
                                                                                                          in the same way as the count input (CP1) of UP (increment) mode.
         H     BBBB
CP1                                                                                                   2. A must be greater than the minimum signal width and B must be at
                                                                                                          least 1/2 the minimum signal width. If they are less, a count error of 1
         L                                                                                                may occur.
                                                                                                          Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz)
         H                                                                                                100 s (when maximum counting speed = 5 kHz)
CP2
                                                                                                      3. The meaning of the H and L symbols in the tables is explained below.
         L

                                             3                                           3

Present                                2           2                                  2                    Input method No-voltage input                      Voltage input
value                                                                                                                                                          (PNP input)
                                                                                               Symbol                                       (NPN input)

                     1                                          1

                             0                                                                             H                                Short-circuit     4.5 to 30 VDC
                  0
                                                                                                           L                                   Open              0 to 2 VDC
B must be at least 1/2 the minimum signal width. (See note 2.)

                                                                                                           Multifunction Counter H7BX                                                                13
Input/Output Mode Settings                                                         One-shot output from OUT1  (The one-shot output time
                                                                                                               can be set in the range
Operation for 1-stage models is the same as that for OUT2.                                                     0.01 to 99.99s.)
When using a 2-stage model as a 1-stage counter, total and preset counter,
or dual counter, OUT1 and OUT2 turn ON and OFF simultaneously.              Self-holding Self-holding One-shot output

                                                                            output  output   from OUT2

                                     Input mode                                              Operation after count
                                                                                                    completion
                              UP     DOWN                                   UP/DOWN A, B, C

                   Reset/                                                                    The outputs and present
                   reset 1                                                                   value display are held
                                                                                             until reset/reset 1 input
                 999999                                                                      turns ON.

                  Set
                  value 2
                  Set

         N value 1

                          0

         OUT1

         OUT2

                   Reset/                                                                    The present value
                   reset 1                                                                   display continues to
                 999999                                                                      increase/decrease. The
                  Set                                                                        outputs are held until
                  value 2                                                                    reset/reset 1 input turns
                  Set                                                                        ON.

         F value 1                                                                           As soon as the count
                                                                                             reaches SV, the present
                          0                                                                  value display returns to
                                                                                             the reset start status.
                   OUT1                                                                      The present value
                                                                                             display does not show
                   OUT2                                                                      the present value upon
                                                                                             count-up.
         Reset/                                                                              The outputs repeat one-
         reset 1                                                                             shot operation.
                                                                                             OUT1 self-holding
         999999                                                                              output turns OFF after
                                                                                             the OUT2 one-shot
         Set                                                                                 output time.
         value 2                                                                             The OUT1 one-shot
                                                                                             output time is
Output   Set                                                                                 independent of OUT2.
mode C   value 1
                                                                                             The present value
                0                                                                            display returns to the
                                                                                             reset start status after
setting  OUT1                                                                                the one-shot output
                                                                                             time.
         OUT2                                                                                The outputs repeat one-
                                                                                             shot operation.
                    Reset/                                                                   OUT1 self-holding
                    reset 1                                                                  output turns OFF after
                  999999                                                                     the OUT2 one-shot
                   Set                                                                       output time.
                   value 2                                                                   The OUT1 one-shot
                   Set                                                                       output time is
                                                                                             independent of OUT2.
         R value 1
                                                                                             The present value
                           0                                                                 display continues to
                                                                                             increase/decrease.
                    OUT1                                                                     OUT1 self-holding
                                                                                             output turns OFF after
                    OUT2                                                                     the OUT2 one-shot
                                                                                             output time.
                    Reset/                                                                   The OUT1 one-shot
                    reset 1                                                                  output time is
                  999999                                                                     independent of OUT2.
                   Set
                   value 2
                   Set

         K-1 value 1

                           0

                    OUT1

                    OUT2

14       Multifunction Counter H7BX
                                                    One-shot output from OUT1                                                                     (The one-shot output time
                                                                                                                                                  can be set in the range
                                                                                                                                                  0.01 to 99.99s.)

                                            Self-holding Self-holding One-shot output

                                            output  output   from OUT2

                            UP  Input mode  UP/DOWN A, B, C                    Operation after count
                                DOWN                                                   completion

            Reset/                                                             The present value display
            reset 1                                                            does not change during the
                                                                               one-shot output time
            999999                                                             period, but the actual count
                                                                               returns to the reset start
            Set                                                                status.
            value 2                                                            The outputs return to the
                                                                               one-shot start state and
            Set                                                                repeat one-shot operation.
                                                                               OUT1 self-holding output
         P  value 1                                                            turns OFF after the OUT2
                                                                               one-shot output time.
                 0                                                             The OUT1 one-shot output
                                                                               time is independent of
            OUT1                                                               OUT2.

            OUT2                                                               The present value
                                                                               continues to increase/
            Reset/                                                             decrease for the one-shot
            reset 1                                                            output time, but returns to
                                                                               the reset start status after
            999999                                                             the one-shot output time
                                                                               has elapsed.
            Set                                                                The outputs repeat one-
                                                                               shot operation.
            value 2                                                            OUT1 self-holding output
                                                                               turns OFF after the OUT2
Output      Set                                                                one-shot output time.
                                                                               The OUT1 one-shot output
mode     Q  value 1                                                            time is independent of
setting            0                                                           OUT2.

            OUT1

            OUT2

                  Reset/                                                       The present value display
                  reset 1                                                      and OUT1 self-holding
                                                                               output is held until reset/
                 999999                                                        reset 1 input turns ON.
                 Set                                                           OUT1 and OUT2 are
                 value 2                                                       independent.
                 Set

         A value 1

                         0

                  OUT1

                             OUT2

Note 1. When the present value reaches 999999, it returns to 0.
       2. Counting cannot be performed while the reset/reset 1 input is ON.
       3. If reset/reset 1 input turns ON while the one-shot output is ON, one-shot output turns OFF.
       4. If there is power failure while an output is ON, the output will turn ON again when the power supply has recovered.
           For a one-shot output, the output will turn ON again for the duration of the output time setting once the power supply has recovered.
       5. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON.
       6. The set values are between 0 and 999999.

                                            Multifunction Counter H7BX                                                                            15
                                                               Self-holding  Instanta-  One-shot  (The one-shot output time
                                                                  output      neous       output  can be set in the range 0.01
                                                                             (equals)             to 99.99s.)
                                                                              output

                                                  Input mode                 Operation after count completion
                                              UP/DOWN A, B, C

                  Reset/reset 1

                      999999
                  Set value 2

                  Set value 1                                                The display continues to increase/
                                                                             decrease until the overflow or
    K-2           0                                                          underflow value is reached.
                                                                             Only a one-shot output is possible.
                  -99999

                  OUT1

                  OUT2

               D  Reset/reset 1                                              The display continues to increase/
                         999999                                              decrease until the overflow or
Output                                                                       underflow value is reached. The
mode                Set value 2                                              outputs are ON while the count is
setting             Set value 1                                              equal.

               L                 0                                           The display continues to increase/
                         -99999                                              decrease until the overflow or
                                                                             underflow value is reached.
                           OUT1                                              OUT1 is held while the present value
                                                                             is less than or equal to set value 1.
                           OUT2                                              OUT2 is held while the present value
                                                                             is greater than or equal to set value 2.
                  Reset/reset 1
                         999999

                    Set value 2
                    Set value 1

                                 0
                         -99999

                           OUT1

                           OUT2

                  Reset/reset 1

                      999999                                                 The display continues to increase/
                  Set value 2                                                decrease until the overflow or
                                                                             underflow value is reached.
                  Set value 1                                                OUT1 is held while the present value
                                                                             is greater than or equal to set value 1.
    H             0                                                          OUT2 is held while the present value
                                                                             is greater than or equal to set value 2.
                  -99999                                                     Note: H mode is available only when

                  OUT1                                                               using a 2- stage counter.

                  OUT2

Note 1. Counting cannot be performed while the reset/reset 1 input is ON.
       2. If reset/reset 1 input turns ON while the one-shot output is ON, the one-shot output turns OFF.
       3. If there is power failure while the output is ON, the output will turn ON again when the power supply has recovered. For a one-shot output, the output will turn
           ON again for the duration of the output time setting once the power supply has recovered.
       4. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON.
       5. The set values are between -99999 and 999999.

16                Multifunction Counter H7BX
Total and Preset Counter Operation
The H7BX has a total counter separate from the 1-stage preset counter for counting the total accumulated value.

      Reset/reset 1                                                                                             The total counter continues to count the total
                                                                                                                 accumulated value when the present value is reset
Total reset/reset 2                                                                                              using reset/reset 1 input (Reset Key).
      Present value
                       0                                                                                        The total count value is reset when the total reset/
              999999                                                                                             reset 2 input is turned ON.
                                                                                                                 If the Reset Key is pressed while the total count
Total count value                                                                                               value is displayed, the total count value is reset.
                       0                                                                                         The present value is also reset at this time.

                                                                                                                The counting range of the total counter is -99,999
                                                                                                                 to 999,999. The total count value returns to 0 when
                                                                                                                 it reaches the full scale limit.

Batch Counter Operation
The H7BX has a batch counter separate from the 1-stage preset counter for counting the number of times the count has been completed.

                            Reset 1

         Reset 2 (batch                      2                                                                  The batch counter continues after count
          counter reset)             1                                                                           completion.

                Set value                                                                                       Batch output is held until batch counter reset input
          Present value                                                                                          turns ON.

                           0                                                                                    When the batch counter reset input is turned ON,
                                                                                                                 the batch count value is reset, and batch output
                    OUT2                                                                                         turns OFF.
Batch count set value
                                                                                                                If the Reset Key is pressed while the batch count
           (Sub-display)                                                                                         value is displayed, the batch count value is reset
    Batch count value                                                                                            and batch output turns OFF. The present value is
                                                                                                                 also reset at this time.
          (Main display)
                           0

                     OUT1 (batch output)

                                                 Note: The above is for when the output mode is C.

Note 1. The batch count value is held at 0 while the batch counter reset input is on.
       2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
       3. The batch count value returns to 0 when it reaches 999,999.
       4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
       5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.
       6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value.

Dual Counter Operation
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set
value for which output turns ON when the set value matches the added or subtracted result.

(1) Dual Count Calculating Mode = ADD              (2) Dual Count Calculating Mode = SUB
   Dual count value = CP1 PV + CP2 PV                 Dual count value = CP1 PV - CP2 PV

                 Reset 1                                            Reset 1                                     The operation after count completion for the dual
           (CP1 reset)                                        (CP1 reset)                                        counter value is determined by the output mode.

                 Reset 2                                            Reset 2                                     The CP1 present value is reset when reset 1 input
           (CP2 reset)                                        (CP2 reset)                                        is turned ON and the CP2 present value is reset
                                                   Dual count set value                                          when reset 2 input is turned ON.
Dual count set value
                                                       Dual count value                                        If the Reset Key is pressed while the dual count
    Dual count value                                                        0                                    value, CP1 present value, or CP2 present value is
                         0                                                                                       displayed, all of the present values are reset and
                                                     CP1 present value                                           the outputs turn OFF. At this time, counting is not
  CP1 present value                                                                                              possible for CP1 or CP2 inputs.
                         0                                                  0
                                                     CP2 present value
  CP2 present value
                         0                                                  0

OUT1, 2                                                       OUT1, 2
Note: The above is for when the output mode is N.
                                                   Note: The above is for when the output mode is K-2.
                                                          SUB mode can be used only when K-2, D, L, or H
                                                          is selected as the output mode with 6-digit models.

Note 1. Counting is not possible for CP1 while the reset 1 input is ON. CP2 is not affected. The dual count value will be calculated based on a CP1 present value of 0.
       2. Counting is not possible for CP2 while the reset 2 input is ON. CP1 is not affected. The dual count value will be calculated based on a CP2 present value of 0.
       3. The counting range for the dual count value is -99,999 to 999,999.
           The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999.
           If a present value exceeds 999,999, FFFFFF will be displayed to indicate an overflow, and all counting will stop.

                                                                                                               Multifunction Counter H7BX                     17
Reset Function List

Function              1-stage/2-stage   Total and preset counter               Batch counter                          Dual counter
Display in run             counter
mode                                    Present value/     Total count         Present value/       Batch count           Dual count    CP1 present
Reset/reset 1        Present value/set     set value           value              set value         value/batch       value/dual count    value/CP2
Total reset/reset 2      value (1, 2)                                                             count set value
                                                                                                                           set value    present value
Reset Key            Present value and
                         output reset.  Present value and output reset.        Present value and output reset.        Only the CP1 present value is reset.

                           No effect.   Only the total count value is reset.   Batch count value and batch output     Only the CP2 present value is reset.
                                                                                                   reset.
                     Present value and
                         output reset.  Present value and   Present value,     Present value and    Present value,     CP1 present value, CP2 present
                                           output reset.   total count value,     output reset.   batch count value,  value, dual count value, and output
                                                           and output reset.                       output and batch
                                                                                                                                         reset.
                                                                                                     output reset.

18  Multifunction Counter H7BX
Operating Procedures (Tachometer Function) (H7BX-AW@ only)
Switching from Counter to Tachometer

The H7BX is factory-set to the 2-stage                                                                                                      Power ON
counter configuration. To switch to the                                                                                                     Run mode
tachometer configuration, use the
procedure shown on the right. For details,
refer to page 23.

                                                                                   Configuration selection mode

Note: Hold down the       Key and then press                                       Configuration              Key + Up 1 Key for at
                                                                                   selection           least 1 s (See note.)
   the Up 1 Key for at least 1 s.

   The mode will not change if the Up 1                                            Switch from 2cnt to taco (tachometer) with the Up Key.

   Key is pressed first.

Settings for Basic OperationsX CHXINXAX   X  No. X
                           Settings for basic functions can be performed with just the DIP switch.INMADE

                                                                                             Be sure to turn ON pin 1.Lot
                                                          OMRON Corporation

                                        COUNTER H7BX-A

                                                                                                       12345678

                                                                                   ON
                                                                                   OFF

            Item                                            OFF                       ON                         Pin 3               Pin 4   Tachometer output mode
                                                          Disabled                 Enabled                       OFF                 OFF         Upper and lower limit
1 DIP switch settings enable/disable                                               10 kHz                         ON                 OFF                    Area
                                                           30 Hz                                                 OFF                  ON                Upper limit
2 Counting speed                                                                                                  ON                  ON                Lower limit

3                                                         Refer to the table on the right.                       Pin 4               Pin 5       Average processing
      Tachometer output mode                                                                                     OFF                 OFF    OFF (no average processing)
                                                                                                                  ON                 OFF
4                                                                                                                OFF                  ON                  2 times
                                                                                                                  ON                  ON                  4 times
5                                                         Refer to the table on the right.                                                                8 times
      Average processing

6

7                 ---                                                         ---        ---
                                                                             NPN        PNP
8 NPN/PNP input mode

Note: All pins are factory-set to OFF.

   The ON/OFF status of the DIP switch                                             Cofnuvnecntiioennt
   pins can be confirmed using the front
   display. For details, refer to page 23.

   Caution            Always turn OFF the power supply before changing the DIP switch settings.
                      Always turn ON pin 1 when performing settings with the DIP switch. Performing settings with the DIP switch

                       is disabled when pin 1 is OFF.
                      DIP switch setting changes will be updated when the power is turned ON. Perform the settings before performing

                       installation and supplying power.
                      Properly set the DIP switch to match the item being counted (or measured) and use the DIP switch monitor for

                       confirmation.

After setting the DIP switch for basic operations, advanced functions (see note) can be added using the operation keys. For details,
refer to page 20.

Note: Advanced functions consist of the decimal point position, prescale value, auto-zero time, startup time, display color,
        and key protect level.

                                                                                                                 Multifunction Counter H7BX           19
When the H7BX using as a tachometer, switch to the tachometer configuration using the procedure given on page 23.

Settings for Advanced Functions
           Settings that cannot be performed with the DIP switch are performed with the operation keys.

                    Power ON

    Run mode                                              For details on operations in run mode, refer to page 22.

                           (See note 1.)   (See note 2.)  Note: 1. If the mode is switched to the function setting mode during operation, operation will
                                 3 s min.  3 s min.                  continue.

                                                                  2. Changes made to settings in function setting mode are enabled for the first time when
                                                                     the mode is changed to run mode. Also, when settings are changed, the counter is
                                                                     automatically reset (measured values initialized and outputs turned OFF) on returning
                                                                     to run mode.

                                                          The characters displayed in reverse video are the initial values.
                                                          When performing settings with operation keys only, turn ON pin 1 of the DIP switch to OFF (factory setting). If
                                                          pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed.

                                           Tachometer      Set the tachometer output mode with any of the Up Keys.
                                           output mode           (HI-LO) (AREA) (HI-HI) (LO-LO)
                                           (TOTM)

                                           Counting       Set the counting speed with any of the Up Keys.
                                           speed                  (30 Hz) (10 kHz)
                                           (CNTS)
                                                          Set the decimal point position with any of the Up Keys.
                                           Decimal
                                           point          (No decimal (One digit           (Two digits      (Three digits
                                           position                                       after decimal     after decimal
                                           (DP)           point)  after decimal
                                                                                              point)            point)
                                           Prescale                         point)
                                           value
                                           (PSCL)          Set the number for each digit with the Up Keys.

                                                          (0.001) (1.000) (99.999)

    Function setting mode                  Average         Set the average processing with any of the Up Keys.
                                           processing
                                           (AVG)          (No average (Average      (Average  (Average

                                           Auto-zero      processing) of 2          of 4      of 8
                                           time
                                           (AUTZ)                 measurements) measurements) measurements)

                                                          Set the number for each digit with the Up Keys.

                                                          (0.1 s) (99.9 s)

                                           Startup         Set the number for each digit with the Up Keys.
                                           time                  (0.0 s) (99.9 s)
                                           (STMR)

                                           NPN/PNP         Set the NPN/PNP input mode with any of the Up Keys.
                                           input mode
                                           (IMOD)         (NPN    (PNP
                                                          input)  input)
                                           Display
                                           color          Set the display color with any of the Up Keys.
                                           (COLR)

                                                          (Red) (Green) (Red-green) (Green-red)

                                           Key protect    Set the key protect level with any of the Up Keys.
                                           level                   (KP-1) (KP-2) (KP-3) (KP-4) (KP-5)
                                           (KYPT)

20                         Multifunction Counter H7BX
Explanation of Functions

Settings marked with a star can be performed with the DIP switch.

Tachometer Output Mode (totm)                                                          Auto-zero Time (avt)

Set the output method for control output based on the OUT1/                             It is possible to set the H7BX so that if there is no pulse for a
OUT2 set value. Upper and lower limit (HI-LO), area (AREA),                             certain time the display is force-set to 0. This time is called the
upper limit (HI-HI), and lower limit (LO-LO) can be set.                                auto-zero time. Set the auto-zero time to a time slightly longer
(For details on the operation of the output modes, refer to Output                      than the estimated interval between input pulses. It will not be
Mode Settings on page 22.)                                                              possible to make accurate measurements if the auto-zero time is
                                                                                        set to a time shorter than the input pulse cycle. Setting a time
Counting Speed (cnts)                                                                 that is too long may also result in problems, such as a time-lag
                                                                                        between rotation stopping and the alarm turning ON.
Set the maximum counting speed (30 Hz/10 kHz) for CP1 input.
If contacts are used for input signals, set the counting speed to                        Startup Time (stmr)
30 Hz. Processing to eliminate chattering is performed for this
setting.                                                                                In order to prevent undesired output resulting from unstable input
                                                                                        immediately after the power supply is turned ON, it is possible to
Decimal Point Position (dp)                                                           prohibit measurement for a set time. This time is called the
                                                                                        startup time.
Decide the decimal point position for the measurement value,                            It can also be used to stop measurement and disable output until
OUT1 set value, and OUT2 set value.                                                     the rotating body reaches the normal rate of rotation, after the
                                                                                        power supply to the H7BX and rotating body are turned ON at
Prescale Value (pscl)                                                                 the same time.

It is possible to display the rate of rotation or the speed of a                                                                       Display Startup time
device or machine to which the H7BX is mounted by converting
input pulses to a desired unit. If this prescaling function is not                                                            Comparison
used, the input frequency (Hz) will be displayed.                                                                                      value
The relationship between display and input is determined by the
following equation. Set the prescale value according to the unit                                                              (lower limit)
to be displayed.

    Displayed value = f                                                                                                                     Time
      f: Input pulse frequency (number of pulses in 1 second)
      : Prescale value                                                                                                      Power supply

1. Displaying the Rotation Rate                                                                                     Output (lower limit)

             Display unit           Prescale value ()                                    NPN/PNP Input Mode (imod)
                   rpm                     1/N 60                                     Select either NPN input (no-voltage input) or PNP input (voltage
                   rps                        1/N                                       input) as the input format. Select an NPN input when using a 2-
                                                                                        wire sensor.
N: Number of pulses per revolution                                                      The same setting is used for all external inputs.
                                                                                        For details on input connections, refer to Input Connections on
Example: In order to display the rate of rotation for a machine                         page 6.
       that outputs 5 pulses per revolution in the form @@.@ rpm:
       1. Set the decimal point position to 1 decimal place.                            Display Color (colr)
       2. Using the formula, set the prescale value to 1/N 60 =                       Set the color used for the measurement value.
          60/5 = 12.
                                                                                                       Control output OFF               Control output ON

2. Displaying the Speed                                                                 red                                Red (fixed)

             Display unit           Prescale value ()                                   grn                                Green (fixed)
                                       d 1/N 60
                 m/min                     d 1/N                                          r-g        Measured value displayed    Measured value displayed in
                                                                                                       in red when both control    green when either control output
                   m/s                                                  d: Diameter     (See note 1.)  outputs 1 and 2 are OFF.    1 or control output 2 is ON.
                                                                           of rotating
N: Number of pulses per revolution                                         body             g-r        Measured value displayed    Measured value displayed in red
d: Diameter of rotating body (m)                                                                       in green when both control  when either control output 1 or
d: Circumference (m)                                                                    (See note 2.)  outputs 1 and 2 are OFF.    control output 2 is ON.

Note: Incorrectly setting the prescale value will result in                            Note 1. If the tachometer output mode is set to AREA, however, the measured
          counting errors. Check that the setting has been                                         value is displayed in red when control output 1 is OFF and in green
          performed correctly before using the H7BX.                                               when control output 1 is ON.

Average Processing (aug)                                                                     2. If the tachometer output mode is set to AREA, however, the measured
                                                                                                   value is displayed in green when control output 1 is OFF and in red
Flickering display and output chattering can be prevented by                                       when control output 1 is ON.
using average processing (simple averaging). Average
processing can be set to one of four levels: no average                                  Key Protect Level (kypt)
processing, 2 times (i.e., the average of 2 measurement values),
4 times, or 8 times.                                                                    Set the key protect level.
The measurement cycle will be equal to the sampling cycle                               For details, refer to Key Protect Level on page 24.
(200 ms) multiplied by the average processing setting (i.e., the
number of times). Average processing enables fluctuating input
signals to be displayed stably. Set the optimum number of times
for the application.

                                                                                                       Multifunction Counter H7BX                          21
Operation in Run Mode

    Set the number for each digit with the Up Keys.

                          Measurement value            Measurement Value
                                                        Displays the currently measured value.
                          Measurement value
                          OUT1 set value               OUT1/OUT2 Set Value
                                                        Set OUT1 set value and OUT2 set value. The
                                                        measurement value is compared to OUT1 set value
                                                        and OUT2 set value and output is made according to
                                                        the selected output mode.

                          Measurement value
                          OUT2 set value

Output Mode Settings

             Upper and             (Upper-limit)      ON condition for OUT1: Measurement value  OUT1 set value
             lower limit       OUT2 set value         ON condition for OUT2: Measurement value  OUT2 set value
                          Measurement value
               (HI-LO)
                                   (Lower-limit)
                               OUT1 set value

                                            OUT1

                          OUT2

                               OUT2 set value             Condition  OUT1 set value  OUT2                   OUT1 set value > OUT2
                          Measurement value                                    set value                              set value
                                                      ON condition
              Area             OUT1 set value         for OUT1       OUT1 set value                         OUT2 set value
             (AREA)
                                            OUT1      ON condition   Measurement value  OUT2 Measurement value  OUT1
                                                      for OUT2
                                                                     set value                              set value

                                                                     Measurement value < OUT1 Measurement value < OUT2

                                                                     set value or Measurement set value or Measurement

                                                                     value > OUT2 set value                 value > OUT1 set value

Output mode               OUT2
setting

                              (Upper-limit)
                          OUT2 set value

                          Measurement value

             Upper limit      (Upper-limit)           ON condition for OUT1: Measurement value  OUT1 set value
                (HI-HI)   OUT1 set value              ON condition for OUT2: Measurement value  OUT2 set value

                          OUT1

                          OUT2

                              (Lower-limit)
                          OUT2 set value

                          Measurement value

             Lower limit      (Lower-limit)           ON condition for OUT1: Measurement value  OUT1 set value
               (LO-LO)    OUT1 set value              ON condition for OUT2: Measurement value  OUT2 set value

                          OUT1

                          OUT2

22           Multifunction Counter H7BX
Switching between Using a Preset Counter, Total and Preset Counter, Batch Counter, Dual Counter,
   and Tachometer

Select which H7BX configuration to use (i.e., preset counter, total and preset counter, batch counter, dual counter, or tachometer) in the
configuration selection mode. The H7BX is also equipped with a DIP switch monitor function, a convenient function that enables the
settings of the DIP switch pins to be confirmed using the front display.

                           Power ON

Run Mode                                                                                                                            Up 1 Key
                                                                                                                                          Key
                              (See note 2.)  Up 1 (See note 1.)
                                                                            Caution
                                             1 s min.
                                                                               To change the mode to configuration selection mode, press
Configuration Selection Mode                           Configuration           the Up 1 Key for 1 s min. with the key held down.
                                                       selection               The mode will not change if the Up 1 Key is pressed first.

                                                        Cofnuvnecntiioennt  S e l e c t t h e c o n f i g u r a t i o n w i t h a n y o f t h e Up K e y s .
                                                       DIP switch
                                                       monitor                 (1-stage counter) (2-stage counter) (Total and preset (Batch counter) (Dual counter) (Tachometer)
                                                       (DIP)                                                               counter)

                                                                            Note: 1. The configuration that can be selected depend on the model.
                                                                                    2. The default setting is for a 1-stage preset counter. (For models with a 2-stage setting,
                                                                                        the default is for a 2-stage preset counter.)

                                                                            The status of the DIP switch pins (1 to 8) can be confirmed using the Up Keys.
                                                                            Note: This display is possible only if DIP switch pin 1 (DIP switch settings) is set to ON

                                                                                    (i.e., enabled).

                                                                                   Example

                                                                                                 12345678
                                                                               ON

                                                                              OFF

                                                                                                                                                Indicates that DIP switch pin 8 is ON.
                                                                                                                                                Indicates that DIP switch pin 7 is OFF.
                                                                                                                                                Indicates that DIP switch pin 6 is ON.
                                                                                                                                                Indicates that DIP switch pin 5 is OFF.
                                                                                                                                                Indicates that DIP switch pin 4 is ON.
                                                                                                                                                Indicates that DIP switch pin 3 is OFF.
                                                                                                                                                Indicates that DIP switch pin 2 is ON.
                                                                                                                                                Indicates that DIP switch pin 1 is ON.

Note: 1. When the mode is changed to configuration selection mode, the present value is reset, outputs turns OFF, and counting (measuring)
           stops.

        2. Setting changes made in configuration selection mode are enabled when the mode is changed to run mode.
           If the configuration is changed, the set value (or set value 1 and set value 2), OUT1 set value or OUT2 set value are initialized.

                                                                            Multifunction Counter H7BX                                         23
Key Protect Level

When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by
specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/
OFF status of the key protect switch after the H7BX is mounted to the panel.

                                                                                         X   XXX    X  No. X
                                                                                            CHINA  IN  MADE

                                                                                                              Lot      OMRON Corporation

                                                                                            COUNTER H7BX-A

                                Key protect indicator

       Level       Meaning                              Changing mode                                              Details                Reset Key     Up/Down Keys
                                                           (See note.)                                                                               (Up Keys for 6-digit
       KP-1                                                                              Switching display in
(default setting)                                                                               run mode                                                     models)

       KP-2                                                    No                                             Yes                         Yes                  Yes

                                                               No                                             Yes                         No         Yes

    KP-3                                                       No                                             Yes                         Yes        No

    KP-4                                                       No                                             Yes                         No         No

    KP-5                                                       No                                                  No                     No         No

Note: Changing to configuration selection mode and function selection mode.

Self-diagnostic Function

The following displays will appear if an error occurs.

    Main display   Sub-display                          Error                            Output status                    Correction method          Set value after reset
                                                                                           No change                                                        No change
    -----          No change    Present value underflow                                    No change                   Either press the Reset
                                (See note 2.)                                                                          Key or turn ON reset                 No change
    (See note 1.)                                                                                                      input.
                                                                                                                                                            No change
    fffff          No change    Present value overflow                                                                 Either press the Reset               No change
                                (See note 3.)                                                                          Key or turn ON reset
    (See note 1.)                                                                                                      input. (See note 4.)                       0

    e1             Not lit      CPU                                                         OFF                        Either press the Reset
                                                                                            OFF                        Key or reset the power
    e2             Not lit      Memory error (RAM)                                          OFF                        supply.

    e2             sum          Memory error (EEP)                                                                     Reset the power supply.
                                (See note 5.)
                                                                                                                       Reset to the factory
                                                                                                                       settings using the Reset
                                                                                                                       Key.

Note 1. Display flashes (1-second cycles).
       2. Occurs when the present value or the total count value goes below -99,999
       3. Occurs when the present value reaches 999,999 under the following conditions:
            The output mode is K-2, D, L, or H.
            The H7BX is set for dual counter operation.
       4. Except when the H7BX is used as a tachometer.
       5. Includes the case where the EEPROM has reached its overwrite lifetime.

24        Multifunction Counter H7BX
Safety Precautions                                                       supply capacity, operation may not start. Be sure to use a
                                                                         power supply with a sufficient capacity.
                               Caution                                 Use a commercial power supply as the AC power supply for
                                                                         the H7BX. Using an inverter output with an output frequency of
Minor injury due to electric shock may occasionally                      50/60 Hz as the power supply may cause the H7BX to
occur. Do not touch any of the terminals while                           produce smoke or become damaged by burning.
power is being supplied.                                              Use a switch, relay, or other device with contacts so that the
                                                                         rated power supply voltage will be reached within 2 s. If the
Fire may occasionally occur. Tighten the terminal                        power supply voltage is not reached quickly enough, the
screws to a torque of 0.5 to 0.6 Nm (4.4 to 5.3 in-lb).                 outputs may malfunction.
                                                                      Use a switch, relay, or other device with contacts so that the
Minor injury due to explosion may occasionally                           rated power supply voltage will be reached within 2 s. If the
occur. Do not use the H7BX where subject to                              power supply voltage is not reached quickly enough, the
flammable or explosive gas.                                              outputs may malfunction.

If the output relay is used beyond its life                            Installation and Wiring
expectancy, its contacts may become fused or
there may be a risk of fire.                                           To mount the H7BX to a panel, attach the two supplied
Use the output relay within its rated load and                           adapters to the left and right sides of the H7BX, and securely
electrical life expectancy. The life expectancy of the                   tighten the knurled screws on the adapters by hand,
output relay varies considerably according to its                        maintaining a balance between them. Damage may result if
usage.                                                                   the knurled screws are excessively tightened with pliers or
                                                                         other tools.
Minor electric shock, fire, or malfunction may
occasionally occur. Never attempt to disassemble,                      Be sure to wire the terminals correctly.
modify, or repair the H7BX or touch any of the                         Up to two wires of the same size and type can be inserted into
internal parts.
                                                                         a single terminal.
                 Precautions for Safe Use                              Do not connect more than two crimp terminals to each H7BX

Operating Environment                                                   terminal.
The H7BX is intended for indoor use only. Do not use the             Use the specified wires for wiring.

   H7BX outdoors or in any of the following locations.                   Applicable wire: AWG 24 to AWG 18 (equal to a cross-
   Locations subject to sudden or extreme changes in                    sectional area of 0.20 to 0.82 mm2)
    temperature.                                                         Solid wire or twisted wire (copper), operating temperature over
   Locations where high humidity may result in condensation.            70C.
   Locations subject to direct sunlight.                              Separate the H7BX, the devices that generate input signals,
   Locations subject to corrosive gas.                                  and input signal wires from any potential sources of noise,
   Locations subject to excessive dust or dirt.                         such as high-voltage lines.
This is a class A product (for industrial environments). In
   residential areas, it may cause radio interference, in which        Handling
   case the user may be required to take adequate measures to
   reduce interference.                                                Do not use organic solvents (such as paint thinner or benzine),
Use the H7BX within the specified ratings for operating                strong alkaline, or strong acids because they will damage the
   temperature and humidity. Temperature rise may shorten the            external finish.
   service life of H7BX if it is used near a power supply or other
   heat-generating objects.                                           Approximately 14 V will be output to the input terminals when
Use the H7BX within the specified ratings for vibration, shock,        the H7BX is used with the key protection input terminals and
   and splashing water.                                                  no-voltage input (NPN input) is used. To prevent charging
The H7BX is not oil resistant. Do not use it in locations subject      accidents, connect a diode to the power supply circuit of input
   to oil.                                                               devices if input devices are used with a power supply of less
Install the H7BX well away from any sources of excessive               than 14 V.
   static electricity, such as pipes transporting molding materials,
   powder, or liquids.                                                 Do not connect loads that exceed the rated output current.
Store the H7BX within the specified ratings. If the H7BX has           The output elements may be destroyed, possibly resulting in
   been stored at temperatures of -10C or lower, let it stand for       short-circuit or open-circuit faults.
   3 hours or longer at room temperature before turning ON the
   power supply.                                                       When using heaters, be sure to use a thermal switch for the
                                                                         load circuit.
Power Supply
Maintain voltage fluctuations in the power supply within the         Always connect a diode to protect against counter
                                                                         electromotive force when using an inductive load. H7BX
   specified range.                                                      electromotive force may destroy output elements, possibly
Internal elements may be destroyed if a voltage beyond the             resulting in short-circuit or open-circuit faults.

   rated voltage is applied.                                           Install a switch or circuit breaker that allows the operator to
When the power is turned ON, an inrush current will flow for a         immediately turn OFF the power, and label it to clearly indicate
                                                                         its function.
   short time (approx. 10 A for 2 ms). Depending on the power
                                                                      Check that the display (backlight and LCD) is operating
                                                                         normally. Some operating environments may accelerate
                                                                         deterioration of the indicators, LCD, and resin components
                                                                         and cause display malfunctions. Periodically inspect and
                                                                         replace parts.

                                                                      Multifunction Counter H7BX  25
                       Precautions for Correct Use

Inrush current generated by turning ON or OFF the power
  supply may deteriorate contacts in the power supply circuit.
  Turn ON or OFF using a device with a rated current of 10 A or
  higher.

Input signals may be accepted, not accepted, or unstable for
  the following time when the power supply is turned ON or
  OFF. Set the system to allow leeway in the timing of input
  signals.

    Power supply ON
                       OFF

                                   200 ms 0 to 90 ms 5 ms 0 to 1 s

                            Input  Impossible   Un-    Possible  Unstable Impossible
                                               stable

This H7BX always compares the count value with the set
  value. Thus, if you change the set value during operation,
  please remember that the output will turn ON when the set
  value becomes equal to the count value.

With the factory setting, the output will turn ON when power is
  supplied to the H7BX because the set value and count value
  are both zero. While resetting, however, the output stays OFF.

EEPROM is used as memory when the power is interrupted.
  The write life of the EEPROM is 100,000 writes. The EEPROM
  is written when settings are changed, or the power is tuned
  OFF.

Water resistance will be lost if the front sheet is peeled off or
  torn. Do not use the H7BX if the front sheet is missing or torn.

Abide by all local ordinances and regulations when disposing
  of the H7BX.

External Power Supply
  Reduce the load current as shown in the diagram on the right
  according to the power supply voltage if a DC power supply is
  used for models specified for 24 VAC/12 to 24 VDC.

    Load current (mA)  100

                       20

                       0           10.8                15

                                               Power supply voltage (VDC)

26                     Multifunction Counter H7BX
Terms and Conditions of Sale

1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed                      ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
     part of all quotes, agreements, purchase orders, acknowledgments, price lists,              BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
     catalogs, manuals, brochures and other documents, whether electronic or in                  PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
     writing, relating to the sale of products or services (collectively, the "Products")        INTENDED USE. Omron further disclaims all warranties and responsibility of
     by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron                      any type for claims or expenses based on infringement by the Products or oth-
     objects to any terms or conditions proposed in Buyer's purchase order or other              erwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obli-
     documents which are inconsistent with, or in addition to, these Terms.                      gation hereunder shall be, at Omron's election, to (i) replace (in the form
                                                                                                 originally shipped with Buyer responsible for labor charges for removal or
2. Prices; Payment Terms. All prices stated are current, subject to change with-                 replacement thereof) the non-complying Product, (ii) repair the non-complying
     out notice by Omron. Omron reserves the right to increase or decrease prices                Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
     on any unshipped portions of outstanding orders. Payments for Products are                  the non-complying Product; provided that in no event shall Omron be responsi-
     due net 30 days unless otherwise stated in the invoice.                                     ble for warranty, repair, indemnity or any other claims or expenses regarding
                                                                                                 the Products unless Omron's analysis confirms that the Products were prop-
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices              erly handled, stored, installed and maintained and not subject to contamina-
     sent to Buyer after deducting transportation charges, taxes and duties, and will            tion, abuse, misuse or inappropriate modification. Return of any Products by
     be allowed only if (i) the invoice is paid according to Omron's payment terms               Buyer must be approved in writing by Omron before shipment. Omron Compa-
     and (ii) Buyer has no past due amounts.                                                     nies shall not be liable for the suitability or unsuitability or the results from the
                                                                                                 use of Products in combination with any electrical or electronic components,
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or                 circuits, system assemblies or any other materials or substances or environ-
     the maximum legal rate, whichever is less, on any balance not paid within the               ments. Any advice, recommendations or information given orally or in writing,
     stated terms.                                                                               are not to be construed as an amendment or addition to the above warranty.
                                                                                                 See http://www.omron247.com or contact your Omron representative for pub-
5. Orders. Omron will accept no order less than $200 net billing.                                lished information.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all               14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
                                                                                                 FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
     costs involved in, obtaining any government approvals required for the impor-               LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
     tation or sale of the Products.                                                             WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
7. Taxes. All taxes, duties and other governmental charges (other than general                   BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
     real property and income taxes), including any interest or penalties thereon,               Further, in no event shall liability of Omron Companies exceed the individual
     imposed directly or indirectly on Omron or required to be collected directly or             price of the Product on which liability is asserted.
     indirectly by Omron for the manufacture, production, sale, delivery, importa-          15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
     tion, consumption or use of the Products sold hereunder (including customs                  their employees from and against all liabilities, losses, claims, costs and
     duties and sales, excise, use, turnover and license taxes) shall be charged to              expenses (including attorney's fees and expenses) related to any claim, inves-
     and remitted by Buyer to Omron.                                                             tigation, litigation or proceeding (whether or not Omron is a party) which arises
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory              or is alleged to arise from Buyer's acts or omissions under these Terms or in
     to Omron, Omron reserves the right to stop shipments or require satisfactory                any way with respect to the Products. Without limiting the foregoing, Buyer (at
     security or payment in advance. If Buyer fails to make payment or otherwise                 its own expense) shall indemnify and hold harmless Omron and defend or set-
     comply with these Terms or any related agreement, Omron may (without liabil-                tle any action brought against such Companies to the extent based on a claim
     ity and in addition to other remedies) cancel any unshipped portion of Prod-                that any Product made to Buyer specifications infringed intellectual property
     ucts sold hereunder and stop any Products in transit until Buyer pays all                   rights of another party.
     amounts, including amounts payable hereunder, whether or not then due,                 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
     which are owing to it by Buyer. Buyer shall in any event remain liable for all              sive property of Omron Companies and Buyer shall not attempt to duplicate it
     unpaid accounts.                                                                            in any way without the written permission of Omron. Notwithstanding any
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation                     charges to Buyer for engineering or tooling, all engineering and tooling shall
     unless Buyer indemnifies Omron against all related costs or expenses.                       remain the exclusive property of Omron. All information and materials supplied
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery                by Omron to Buyer relating to the Products are confidential and proprietary,
     resulting from causes beyond its control, including earthquakes, fires, floods,             and Buyer shall limit distribution thereof to its trusted employees and strictly
     strikes or other labor disputes, shortage of labor or materials, accidents to               prevent disclosure to any third party.
     machinery, acts of sabotage, riots, delay in or lack of transportation or the          17. Export Controls. Buyer shall comply with all applicable laws, regulations and
     requirements of any government authority.                                                   licenses regarding (i) export of products or information; (iii) sale of products to
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:                   "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of
     a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship              regulated technology or information.
                                                                                            18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
        except in "break down" situations.                                                       and no course of dealing between Buyer and Omron shall operate as a waiver
     b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall          of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
                                                                                                 without Omron's written consent. (c) Law. These Terms are governed by the
        constitute delivery to Buyer;                                                            law of the jurisdiction of the home office of the Omron company from which
     c. All sales and shipments of Products shall be FOB shipping point (unless oth-             Buyer is purchasing the Products (without regard to conflict of law princi-
                                                                                                 ples). (d) Amendment. These Terms constitute the entire agreement between
        erwise stated in writing by Omron), at which point title and risk of loss shall          Buyer and Omron relating to the Products, and no provision may be changed
        pass from Omron to Buyer; provided that Omron shall retain a security inter-             or waived unless in writing signed by the parties. (e) Severability. If any provi-
        est in the Products until the full purchase price is paid;                               sion hereof is rendered ineffective or invalid, such provision shall not invalidate
     d. Delivery and shipping dates are estimates only; and                                      any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
     e. Omron will package Products as it deems proper for protection against nor-               against the amount owing in respect of this invoice. (g) Definitions. As used
        mal handling and extra charges apply to special conditions.                              herein, "including" means "including without limitation"; and "Omron Compa-
12. Claims. Any claim by Buyer against Omron for shortage or damage to the                       nies" (or similar words) mean Omron Corporation and any direct or indirect
     Products occurring before delivery to the carrier must be presented in writing              subsidiary or affiliate thereof.
     to Omron within 30 days of receipt of shipment and include the original trans-
     portation bill signed by the carrier noting that the carrier received the Products
     from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the
     Products will be free from defects in materials and workmanship for a period of
     twelve months from the date of sale by Omron (or such other period expressed
     in writing by Omron). Omron disclaims all other warranties, express or implied.
     (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
     EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1. Suitability of Use. Omron Companies shall not be responsible for conformity                   ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROP-
     with any standards, codes or regulations which apply to the combination of the              ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
     Product in the Buyer's application or use of the Product. At Buyer's request,               OVERALL EQUIPMENT OR SYSTEM.
     Omron will provide applicable third party certification documents identifying          2. Programmable Products. Omron Companies shall not be responsible for the
     ratings and limitations of use which apply to the Product. This information by              user's programming of a programmable Product, or any consequence thereof.
     itself is not sufficient for a complete determination of the suitability of the Prod-  3. Performance Data. Data presented in Omron Company websites, catalogs
     uct in combination with the end product, machine, system, or other application              and other materials is provided as a guide for the user in determining suitabil-
     or use. Buyer shall be solely responsible for determining appropriateness of                ity and does not constitute a warranty. It may represent the result of Omron's
     the particular Product with respect to Buyer's application, product or system.              test conditions, and the user must correlate it to actual application require-
     Buyer shall take application responsibility in all cases but the following is a             ments. Actual performance is subject to the Omron's Warranty and Limitations
     non-exhaustive list of applications for which particular attention must be given:           of Liability.
     (i) Outdoor use, uses involving potential chemical contamination or electrical         4. Change in Specifications. Product specifications and accessories may be
     interference, or conditions or uses not described in this document.                         changed at any time based on improvements and other reasons. It is our prac-
     (ii) Use in consumer products or any use in significant quantities.                         tice to change part numbers when published ratings or features are changed,
     (iii) Energy control systems, combustion systems, railroad systems, aviation                or when significant construction changes are made. However, some specifica-
     systems, medical equipment, amusement machines, vehicles, safety equip-                     tions of the Product may be changed without any notice. When in doubt, spe-
     ment, and installations subject to separate industry or government regulations.             cial part numbers may be assigned to fix or establish key specifications for
     (iv) Systems, machines and equipment that could present a risk to life or prop-             your application. Please consult with your Omron's representative at any time
     erty. Please know and observe all prohibitions of use applicable to this Prod-              to confirm actual specifications of purchased Product.
     uct.                                                                                   5. Errors and Omissions. Information presented by Omron Companies has been
     NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS                                  checked and is believed to be accurate; however, no responsibility is assumed
     RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT                                     for clerical, typographical or proofreading errors or omissions.
     ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
    Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website
    at www.omron.com/oei under the "About Us" tab, in the Legal Matters section.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

OMRON ELECTRONICS LLC                MEXICO SALES OFFICES                OMRON ON-LINE

1 Commerce Drive                     Mexico, D.F. (52) 555 660 31 44     Global
Schaumburg, IL 60173                 Ciudad Jurez (52) 656 623 70 83    www.omron.com
Tel: 847.843.7900                    Monterrey, N.L. (52) 818 377 42 81
                                     Mexicali, B.C. (52) 686 838 01 15   USA
For U.S. technical support or other                                      www.omron247.com
inquiries: 800.556.6766              BRAZIL SALES OFFICES
                                                                         Canada
OMRON CANADA, INC.                   Sao Paulo  (55) 11 2101 6300        www.omron.ca

885 Milner Avenue                    ARGENTINA SALES OFFICES             Brazil
Toronto, Ontario M1B 5V8                                                 www.omron.com.br
Tel: 416.286.6465
                                     Cono Sur   (54) 11 4787 1129

                                     CHILE SALES OFFICES

                                     Santiago   (56) 2206 4592

                                     OTHER LATIN AMERICAN SALES

                                     mela@omron.com

Cat. No. M077-E1-01  11/07           Specifications subject to change without notice  Printed in USA
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved