器件描述

counter digital lcd 12-24vdc npn

参数
Datasheets:
H7BR:
PCN Obsolescence/ EOL:
H7BR Series Feb/2008:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Panel Meters - Counters, Hour Meters
Series: H7BR
Type: Preset
Operating Mode: Up, Down, Command, Individual, Quadrature
Count Rate: 30Hz, 1kHz, 5kHz, 10kHz
Time Format: -
Number Of Characters Per Row: 6, 6
Display Type: LCD - Black Characters, Green Backlight
Display Characters - Height: -
Input Type: Voltage
Output Type: Relay, Solid State
Voltage - Supply: 24VAC, 12 ~ 24VDC
Reset: External, Front Panel
Panel Cutout Dimensions: Square - 68.00mm x 68.00mm
Mounting Type: Panel Mount
Termination Style: Screw Terminal
Ingress Protection: IP54 (Face)
Operating Temperature: -10°C ~ 55°C
Weight: -
Associated Product: Y92A-72T-ND - TERMINAL COVER FOR H7BXY92A-72F1-ND - COVER SOFT PROTECTIVE FOR H7BXY92A-72-ND - COVER HARD PROTECTIVE FOR H7BX
Other Names: H7BRCVAC24DC1224

H7BR-CV-AC24/DC12-24器件文档内容

   Digital Counter                                       H7BR

DIN 72 x 72 mm Counters with
Easy-to-use Functions

   Designed with an emphasis on ease of operation.
   All models equipped with prescale function which
   displays in units of actual physical parameters
   (length, volume, etc.).
   H7BR-C large/small discrimination mode useful for
   positioning and production control.
   High-speed response allows 10,000 counts per
   second.
   High-visibility LCD display with built-in backlight.
   Online change of set value possible.
   Meets UL and CSA standards.
   Conforms to EMC standards.
   Conforms to EN61010-1/IEC1010-1.
   Six-language instruction manual provided.

                                                               1
H7BR                                                                                                                                      H7BR

Ordering Information

                                                                                  H7BR Counters

                                                                  Standard                                   Range type
                                                               (with backlight)                             (with backlight)

                                                       One Stage                 Two Stages      One Stage                    Two Stages

                                                       No-voltage Voltage No-voltage Voltage  No-voltage Voltage  No-voltage Voltage

                                                       Input   input  Input       input       Input  input        Input       input

External            Outputs            Control
power supply                           power
                                       source

                                       100 to 240 VAC

                                       50/60 Hz        H7BR-B  H7BR-BV H7BR-BW H7BR-BWV H7BR-C       H7BR-CV      H7BR-CW H7BR-CWV
                                                               H7BR-BV H7BR-BW H7BR-BWV H7BR-C       H7BR-CV      H7BR-CW H7BR-CWV
12/24 VDC           Contact and NPN
(switching)         transistor output
[160 mA at 12 VDC;
80 mA at 24 VDC]                       24 VAC          H7BR-B
                                       12 to 24 VDC

                                       100 to 240 VAC                             H7BR                                        H7BR
                                                                                  -BWVP                                       -CWVP
                                       50/60 Hz        H7BR-BP H7BR-BVP H7BR-BWP              H7BR-CP H7BR-CVP H7BR-CWP
                                                                                  H7BR
                    Contact and PNP                                               -BWVP
                    transistor output

                                       24 VAC          H7BR-BP H7BR-BVP H7BR-BWP              H7BR-CP H7BR-CVP H7BR-CWP       H7BR
                                       12 to 24 VDC                                                                           -CWVP

Note: Specify both the model and control power supply when ordering.
          With shock prevention cover types are named "H7BR-jjjj-500."

  Model Legend

              H7BR-

                           1234

1. Type                                                               3. Input Type

B: Standard                                                           None: No-voltage input
C: +/- range                                                          V: Voltage input

2. Classification                                                     4. Output Type

None: 1-stage set counter                                             None: NPN output
W: 2-stage set counter                                                P: PNP output

  Accessories (Order Separately)                                      Shock Prevention Cover/Y92A-72T

                   Soft Cover/Y92A-72F1
                   Hard Cover/Y92A-72

Note: Models with a Shock Prevention Cover can be ordered by adding "-500" to the end of the model number.
          e.g., H7BR-B-500 (100 to 240 VAC, 50/60 Hz)

2
H7BR                                                                                                                   H7BR

Specifications

             Model            H7BR-B (Standard type)                                  H7BR-C (Range type)
Classification
Mounting method          Digital preset counter
External connections
Enclosure ratings        Flush mounting
Approved standards
Input modes*             Screw terminals

Output modes*            IP54 (panel surface)
Reset system
                         UL508, CSA C22.2 No.14, conforms to EN61010-1/IEC61010-1, EN50081-2, and EN50082-2
Prescaling function
Decimal point            Up (Incrementing), Down (decrementing), and      Reversible
adjustment               reversible                                       Up/Down A (command inputs),
Teaching function        Up/Down A (command inputs),                      Up/Down B (individual inputs),
Batch counting function  Up/Down B (individual inputs),                   Up/Down C (quadrature inputs)
Set compensation         Up/Down C (quadrature inputs)
Gate input
Sensor power supply      N, F, C, R, K, P, Q, A                           K, D, L, H
Input signals
                         External, manual and automatic resets (internal  External and manual resets
Input method             according to C, R, P, AND Q mode operation)

Control outputs          Yes (0.001 to 99.999)

Batch outputs            Yes (Rightmost 3 digits)
Display
Digits                   ---                                              Yes
Memory backup
                         Yes                                              ---

                         ---                                              Yes

                         Yes

                         12 VDC/24 VDC (switching)

                         Count, reset, key protection, and gate inputs

                         Batch count reset input                          Compensation input

                         No-voltage input: Via opening and closing of contact
                         Voltage input: Via high and low signal voltage (key protection is no-voltage input)

                         1 stage model: SPST-NO contact and transistor (NPN or PNP open collector) output
                         2 stage model: 2 stages of SPST-NO contact and transistor (NPN or PNP open collector) output
                         Transistor output can be changed by switch. (Except for batch count output.)

                         Transistor output (NPN or PNP open collector)    ---

                         LCD with backlight

                         6 digits (0 to 999,999)                          6 digits (-999,999 to 999,999)

                         Backup time for power interruption: Approx. 10 years at 20C (lithium battery)

                                                                                                                       3
H7BR                                                                                                          H7BR

   Ratings

Rated supply voltage               100 to 240 VAC, 50/60 Hz
                                   24 VAC/12 to 24 VDC (contains 20% ripple max.)

Operating voltage range            85% to 110% of rated voltage

Current consumption                Approx. 10 VA at 50 Hz, 240 VAC; approx. 6 W at 24 VDC *

Max. counting speeds (CP1, CP2) 30/1k/5k/10 kcps (separate setting for CP1 and CP2)

Compensation and gate input        Set to the faster of the CP1 and CP2 max. counting speeds

Reset                              Min. pulse width for external reset: 1 or 20 ms, also manual reset

Batch count reset                  Min. pulse width: Approx. 20 ms

Key protection                     Response time: 1 s

One-shot time                      10, 50, 100, 200, 500, and 1,000 ms (separate setting for stages 1 and 2)

Count, compensation, reset, batch  No-voltage input
count reset, and gate inputs
                                   ON impedance: 1 k max. (Approx. 2 mA when 0 k)

                                   ON residual voltage: 2 V max.

                                   OFF impedance: 100 k max.

                                   Voltage input (input resistance: approx. 4.7 k)

                                   High level:           4.5 to 30 VDC

                                   Low level:            0 to 2 VDC

Key protection input               No-voltage input

                                   ON impedance:         1 k max. (Approx. 2 mA when 0 k)

                                   ON residual voltage: 1 V max.

                                   OFF impedance: 100 k min.

Control outputs                    Contacts: 3 A at 250 VAC, resistive load (cos  = 1)

                                   Transistor output: Open collector 100mA at 30 VDC max. residual voltage 2 V max. (Approx.
                                   1 V)

External power supply              160 mA, 12 VDC 10% (5% ripple max.)
                                   80 mA, 24 VDC 10% (5% ripple max.)

*When power is turned ON, approx. 8 A inrush current flows for about 2 ms. (24 VDC, 240 VAC)

   Characteristics

Insulation resistance        100 M min. (at 500 VDC) (between current-carrying terminal and exposed non-current-carrying metal
Dielectric strength          parts, and between non-continuous contacts)
Impulse withstand voltage
                             2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non-current-carrying
Noise immunity               metal parts)
Static immunity
Vibration resistance         3 kV (between power terminals) for 100 to 240 VAC type, 1 kV for 24 VAC/12 to 24 VDC
                             4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts for 100 to 240
                             VAC type, 1.5 kV for 24 VAC/12 to 24 VDC.

                             2 kV (between power terminals) and 600 V (between input terminals), square-wave noise by noise
                             simulator (pulse width: 100 ns/1 s, 1-ns rise)

                             Malfunction: 8 kV; destruction: 15 kV

                             10 to 55 Hz with 0.75-mm single amplitude each in three directions
                             10 to 55 Hz with 0.5-mm single amplitude each in three directions

Shock resistance             300 m/s2 (Approx. 30G) each in three directions
                             100 m/s2 (Approx. 10G) each in three directions

Life expectancy              10 million operations min.
                             100,000 operations min. 5 A at 250 VAC in load resistance)

Weight                       Approx. 270 g
Ambient temperature
Ambient humidity             Operating: 10C to 55C (with no icing)
EMC                          Storage: 25C to 65C (with no icing)

Case color                   Operating: 35% to 85%

                             (EMI):                           EN50081-2
                             Emission Enclosure:              EN55011 Group 1 class A
                             Emission AC Mains:               EN55011 Group 1 class A
                             (EMS):                           EN50082-2
                             Immunity ESD:                    EN61000-4-2:4 kV contact discharge

                             Immunity RF-interference:                           8 kV air discharge
                                                              ENV50140: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
                             Immunity Conducted Disturbance:
                             Immunity Burst:                                     10 V/m (Pulse-modulated, 900 MHz)
                                                              ENV50141: 10 V (0.15 to 80 MHz)
                                                              EN61000-4-4:2 kV power-line

                                                                                 2 kV I/O signal-line

                             Light gray (Munsell 5Y7/1)

4
H7BR                                                                                                        H7BR
  Block Diagram

                                LCD drive            System clock  LCD reference
                                                                   voltage generator
                                clock generator generator

         Function setting                   ROM       RAM          LCD driver               LCD
         circuit
                                           Count     Control       One-chip           No-contact outputs
         Key switch circuits               circuits  circuits      microcom-          inverter (DIP switch
                                                                   puter              pins 1,2)
         Input circuits
         (CP1, CP2, com-                             Battery       Power outage       Output circuits
         pensation, gate,                                          detector           (OUT, batch output)
         reset, batch count
         reset, key protec-
         tion)

             AC (DC) input      Power circuits *
         External power supply

        * Power supply is insulated from I/O.

I/O Functions

Inputs   CP1/CP2                Count signal inputs.
                                Up, Down, and Up/Down (command, individual, or quadrature) inputs accepted.
         Reset
                                Resets present value. (to zero in Up modes, to preset with 1-stage models in Down mode, and
         Compensation input     to preset with 2-stage models.)
         (Range type)          Count inputs are not accepted while reset input is ON.
                                Reset indicator lit while reset input is ON.
         Batch count reset
         (Standard type)        On rising edge of up count signal, present count is reset to compensation value and, therefore,
                                count inputs are accepted even if the compensation input is set to ON (not effective for down
         Key protection         count signals.)

Outputs  Gate                   Resets batch count to zero and batch output turns OFF.
         OUT 1.2                Signals are taken in on the ON edge.
                                Batch count signals are not accepted while batch count reset is ON.
         Batch output
         (Standard type)        Makes keys inoperative according to key protection level.
                                Key protection indicator lit while key protection input is ON.
                                Effective when power supply is turned off.
                                Effective when protect terminals are shorted.

                                Inhibits counter operation when gate input is ON.

                                Outputs made according to designated output mode when corresponding preset is reached.
                                Outputs inhibit on the teaching mode.

                                Outputs made when batch counter is up to preset number of batches.
                                Batch output remains ON until batch count reset goes ON.
                                When the number of batches is set to zero, batch counting is performed but batch outputs are
                                not made.
                                Batch counter counts the number of completed counts to the preset for 1-stage models and to
                                preset 2 for 2-stage models.

                                                                                                            5
H7BR                                                                                                                                                             H7BR

Engineering Data                                                                                                        Electrical Life Expectancy
                                                                                                                        (Inductive Load)
  Life Expectancy of Contacts

                        Electrical Life Expectancy
                        (Resistive Load)

         No. of operations (x 103)
                                                                                             No. of operations (x 103)
                                          30 VDC (cos  = 1)                                                                                 30 VDC (L/R = 7 ms)
                       250 VAC (cos  = 1)                                                                                  250 VAC (cos  = 0.4)

                                Load current (A)                                                                              Load current (A)

                     Reference: A current of 0.15 A max. can be switched at 125 VDC (cos  =1) and a current of 0.1 A
                     max. can be switched if L/R = 7 ms. In both cases, a life of 100,000 operations can be expected.

Nomenclature

   Front View                                                                                                                 Operation Key

   Indicator

                                                                            2  3                                        4

   1. Power indicator                                                                                                         9. Increment Keys (1 to 6)
                                                                                                                                  (Used to change the
   2. Key protection indicator                                                                                                    corresponding digit of the set
                                                                                                                                  value. Used to change data in the
   3. Control output indicator                                                                                                    function setting mode.)

   OUT:              1 stage

   OUT1, OUT2: 2 stages                   1                                                                                   10. Code Key (H7BR-C type only)
                                                                                                                                  (Changes code of setting value.)
   4. Batch output indicator              5

   (H7BR-B only)                                                                                                              11. Display Key

   5. Present value                                                                                                           (Switches to the batch count,

   (character height: 12 mm)              8                                                                                   teaching mode, setting displays.

   (Zeroes suppressed)                                                                                                     6  For 2 stage model, switch set value

   6. Set value                           7                                                                                   1,2.)

   (character height: 8 mm)                                                                                                   12. Batch Key (H7BR-B type only)

   (Indicates data in function setting    10                                                                               9  (Switches to the batch display.)

   mode)                                                                                                                      13. Teaching Key (H7BR-C type only)
                                                                                                                                  (Switches to the teaching mode.)
                                                                        15

   7. Set value 1,2 stage indicator.

   8. Batch indicator                                                                                                         14. Mode Key
       (Displays batch count indicator.)                                                                                          (Switches from run mode to
                                                                                                                                  function setting mode. Changes
                                                                               14 12 13 11                                        items in the function setting mode.

                                                                                                                              15. Reset Key
                                                                                                                                  (Resets present value and
                                                                                                                                  outputs.)

6
H7BR                                                                                                H7BR
  Side View

                                    Dip switch

                                                 Switch      1                     2           3             4
                                                                                           Invalid  External
                                                 No.         Operation of each transistor           power supply
                                                                                             ---
                                      Models                 output when count up            ---       12 VDC
                                                                                             ---
                                      One-stage         OFF       ---   Output               ---       24 VDC
                                      Two-stage         ON              OFF to ON                      12 VDC
                                                                  ---
                                                        OFF             Output                         24 VDC
                                                        ON   Output 1   ON to OFF
                                                             OFF to ON
                                                             Output 1   Output 2
                                                             ON to OFF  OFF to ON
                                                                        Output 2
                                                                        ON to OFF

                                    Note: All DIP Switches are set to OFF at the factory.

Operation

  Factory Settings

The following table shows the counter settings when it is shipped. Please change the settings as necessary to suit the system before operation.
Settings and the display receive power from the internal battery and are therefore unaffected by external power interruptions.

            Model                                H7BR-B                                    H7BR-C

Present value                 0                                         0

Presets                       0                                         0

Batch present count           0                                         ---

Batch setting count           0                                         ---

Input mode                    Up                                        Up/Down C (quadrature)

Output mode                   N                                         K

Output 2 time                 (Hold)                                    1,000 ms

Output 1 time (2-stage only)  Hold                                      1,000 ms

CP1 and CP2 counting speeds 30 cps                                      30 cps

Min. reset time               20 ms                                     20 ms

Decimal point                 Far right (no fractions)                  Far right (no fractions)

Prescale                      1,000                                     1,000

Compensation count value      ---                                       0

Key protection level          KP-1                                      KP-1

Note: With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs cannot be used
          without a power supply.

                                                                                                                  7
H7BR                                                                                                                                                    H7BR

   Operational Overview                                                                                  Setting mode

                             Run mode                                                       Press the
                                                                                            MODE Key
                                                               Present value,
                                                               set value 1                                             Input mode

      Press the       Press the                                                                                                              Press the
      DISPLAY Key     DISPLAY Key                                                                                                            MODE Key

                         Present value,                                                     Press the                   Output mode          Press the
                         set value 2                                                        DISPLAY Key                                      MODE Key
                                                                                                                        Output 2 time
                                            Press the                                                                                        Press the
                                            BATCH key                                                                   Output 1 time        MODE Key
                                                                                                                       CP1 and CP2
                      Batch count value                                                                                Count speed           Press the
                                                                                                                       Min. reset time       MODE Key
                                                                                                         Press the
                                                                                                         MODE Key      Decimal point         Press the
                                                                                                                                             MODE Key
       Press the                                                               Press the                               Prescale value
       TEACH key                                                               DISPLAY Key                             Compensation          Press the
                                                                                                                       count value           MODE Key
      Teaching mode
                                                                                                                                             Press the
      Press the MODE  Present value                                                                                                          MODE Key
      or TEACH Key
                                  Press the MODE                                                                                             Press the
                                  or TEACH Key                                                                                               MODE Key

                      Present value,
                      set value 1

                                  Press the MODE
                                  or TEACH Key

                      Present value,
                      set value 2

                                                                                                                       Key protection level

      Note: Set values are changed with the Increment
              Keys (1 to 6).

8
H7BR                                                                                                                    H7BR

Setting Item Table

  Mode    Setting item  Applicable model        Description                           Setting procedure
Run         (Display)
mode       Set value 1  H7BR-Bj H7BR-Cj   Compared to the
           (SET1)                         present value,
Function                Yes  Yes          determines the           Sequence when changing a digit using the
setting    Set value 2                    timing of the control    Keys (1 to 6).
mode       (SET2)                         output according to
                                          the output mode. The     0 1 2 ...... 8 9
          Batch count                     DISPLAY Key
          set value                       switches between         Press the Code Key (+/) to change the plus or
                                          set values 1 and 2.
          Input mode                      (2-stage model only.)    minus sign of the set value if the model is the
          (IN)
                                          Batch output is          H7BR-C.
          Output mode                     turned ON when the
          (OUT)                           set number of times               (+) (blank)         (-)
                                          is counted.
                        Yes  No                                    Sequence when changing a digit using the
                                          Determines the input     Keys (1 to 6).
                                          mode selecting from
                        Yes  Yes          Up, Down, Up/Down                    0 1 2 ...... 8 9
                                          modes.
                                                                   Press keys 1 to 6 to change the mode.
                                          Determines the form
                        Yes  Yes          of the control output.         u* d* uda udb udc
                                          (Refer to the present
                                          value vs. output                  (Up) (Down) (Up/Down A) (Up/Down B) (Up/Down C)
                                          diagrams on pages
                                          15 to 18.)                 *H7BR-B only.
                                          Determines the           Press keys 1 to 6 to change the mode.
                                          output time for
                                          control output              H7BR-B
                                          (Output 2).
                                                                         nf            c RK p                Qa

                                                                             (N) (F)  (C) (R) (K) (P)       (Q) (A)

                                                                   H7BR-C

                                                                   K d l h*                     *2-stage model only.

                                                                   (K) (D) (L) (H)

                                                                   Press keys 1 to 6 to change the Output 2 time. (Applica-
                                                                   ble to output modes C, R, K, P, Q, and A*only.

                                                                   10ms 50ms 100ms 200ms 500ms 1000ms

          Output time Yes    Yes          Determines the           Press keys 1 to 6 to change the set value.
          1 (2-stage
          model only)                     output time of the                          hold (self holding)*
          (OUT)                           control output (OUT

                                          1) for 2-stage model 10ms 50ms 100ms 200ms 500ms 1000ms
                                          counters.

                                                                   *H7BR-BW only.

          CP1 and       Yes  Yes          Switches the count Press keys 1 to 6 to change the set value.

          CP2 Count                       input filter to protect

          speed                           against errant counts                       30 1K sK 10K
                                          due to interference.
          (CP1, CP2)                                                                  (30cps) (1kcps) (5kcps) (10Kcps)

                                                                   The response speeds of the gate input and com-

                                                                       pensation input are both set to the count speed of
                                                                       CP1 or CP2, whichever is faster.

                                                                   The CP1 and CP2 count speed must be set to the

                                                                       same value only when the H7BR is in Up/Down C
                                                                       input mode.

          Min. reset Yes     Yes          Determines the initial Press keys 1 to 6 to change the set value.
          time
          (RST)                           signal width of the

                                          external reset.                             (1 ms) 1  20 (20 ms)

          Decimal       Yes  Yes          Determines the           Move the decimal point position with keys, 1 to 6.

          point                           decimal point

          (------)                        position of the

                                          present and set

                                          values.

                                                                                                                             9
H7BR                                                                                                             H7BR

  Mode    Setting item      Applicable model       Description                                 Setting procedure
            (Display)                                                 Change the value of the digits with the corresponding
Function                H7BR-Bj H7BR-Cj       Can calculate and       keys, 1 to 5.
setting   Prescale                            display a physical
mode      value         Yes  Yes              parameter (volume,                     0 1 2 ..... 8 9
          (PS)                                length, etc.) from the
                        No   Yes              present value. For                                                 54 3 2 1
          Compensa-                           example, if one count
          tion count                          input represented a     Change the value of the digits with the corresponding
          value                               movement of 0.02        keys, 1 to 6.
          (C.C)                               mm, the prescale
                                              value would be 0.02.                   0 1 2 ..... 8 9
                                              Values from 0.001 to
                                              99.999 are possible.

                                              Use compensation
                                              input to change the
                                              count value to set
                                              value.

                                                                      Press the Code Key to change the plus or minus sign of

                                                                      the set value.                (-)

                                                                                      (+) (blank)

          Key           Yes  Yes              Locks certain keys to Sequence when changing the key protection level using

          protection                          prevent accidental the Increment Keys (1 to 6).

          level                               operation. The key

                                              protection level, kP-1    Kp1 Kp2                    Kp3      Kp4
                                              to kP-4, determines
                                              which keys are                                  

                                              locked when the key

                                              protection input is

                                              ON. The locked keys

                                              are crossed out in

                                              the diagram on the                             
                                              right.

Teaching Prescale       No   Yes              ---                     By setting the conversion count value and pressing the
                                                                      TEACH Key, the prescale value is automatically
Mode      value                                                       calculated and set.

          (PS)                                                        By pressing the TEACH Key, the Present value is set as
                                                                      the set value.
          Set value 1 No     Yes              ---
          (two-stage
          model only)
          (SET1)

          Set value 2 No     Yes
          (SET2)

Note:  1. Settings changed in setting mode are not effective until run mode is entered.

       2. Control output is prohibited in teaching mode. Output is OFF in coincidence-ON operation and ON in coincidence-OFF operation.
       3. The TEACH Key is disabled when the H7BR is turned OFF, when no teaching is possible. Other functions are enabled regardless of

           whether the H7BR is turned ON or OFF.

10
H7BR                                                                                                                   H7BR

  Examples                                                           Batch Set Value Change
                                                                     (Applicable to Standard Models Only)
Run Mode                                                             1. Selecting Batch Count Display
                                                                     Switch the count display over to batch count display.
Changing the Set Value                                               Press the BATCH Key.
1. Press the DISPLAY Key to change the displayed preset value 1

    and 2 during operation.

2. Change the set value from 250 to 1,250.                           2. Batch Set Value Change

Pressing keys 1 through 6 increments the corresponding column      Change the batch set value while the batch count is displayed.
                                                                     Pressing keys 1 through 6 increments the corresponding column by
    by1.                                                             1.

Non-significant zeros are normally not shown on the set value       Non-significant zeros are normally not shown on the set value

    display.                                                             display.
                                                                         In order to switch the batch count display over to the count
                                                                         display, press the DISPLAY Key.

Setting Mode                                                         2. Press the MODE Key to scroll successively through the items
                                                                         that can be set. Release the MODE Key to select the desired
Changing Settings in the Function Setting Mode                           item.
1. Press the MODE Key to switch from run mode to setting mode.

    The Counter will continue operation if switched from run

        mode to function setting mode during operation.

    The MODE Key will be locked if the key protection function is

        enabled.

    Settings changed in the function setting mode are not

        effective until run mode is entered. As the operating
        conditions will change in this case, always reset operation
        with the RESET Key or a reset input.

                                                                     11
H7BR                                                                                                               H7BR

3. Changing the selected item                                        Press the DISPLAY Key to return to Run mode from Setting

    Press the MODE Key until the desired item appears                  mode.
    Change the item setting by pressing keys 1 through 6. (Press

        the DISPLAY Key to switch back from function setting mode
        to run mode.)

Teaching Mode ( Range Models Only)

Changing to Teaching Mode (Power Must be ON)
Change from run mode to teaching mode.
Press the TEACH Key.

If prescale teaching is not required, press the MODE Key and go to
Set Value 1 Teaching.

Prescale Teaching                                                   2. Set 10 cm as a converted count value, for example.
1. Perform prescale teaching of the H7BR in teaching mode.
                                                                    Pressing keys 1 through 6 increments the corresponding column by
The prescale display shows 0.000.                                 1.

                                                                     By pressing one of keys 1 through 6, the counter PV (present

                                                                        value) display indicates 0.

12
H7BR                                                                                                                     H7BR

3. Input a count signal corresponding to the conversion count value    Set Value 1 Teaching
    through the external sensor.                                       1. Press the MODE Key to perform the teaching of set value 1,

The display on the right side indicates that an input of 50 counts           provided that the H7BR is a two-stage model.
                                                                       2. Input an appropriate count signal from the external sensor.
    has been input from the external sensor with the controlled        3. Register the count value 250 as the set value, for example.
    object moved 10 cm.
                                                                               Press the TEACH Key.

                                                                        The teaching set value is displayed while the TEACH Key is

                                                                           pressed.

4. Perform prescale value teaching per count.                          Set Value 2 Teaching (Two-stage Models Only)

Press the TEACH Key. (Prescale value 0.2 = 10 cm/50)                   Perform the same procedure as Set Value 1 Teaching above.

If the conversion count value input at step 3 is a negative value,       Press the DISPLAY Key to return to run mode from teaching
                                                                           mode.
    the prescale value will be calculated using the absolute value of
    the conversion count value.

The fraction is rounded off for prescale calculations. (It is

    rounded upward when displaying negative values.)

While the TEACH Key is pressed, the teaching prescale value

    (i.e., 0.2) is displayed.

                                                                       13
H7BR                                                                                                                                                     H7BR

    Input Modes and Count Value

                    Up (increment) mode                                                                     Down (decrement) mode

Count H                                                                           Count       H
input                                                                             input
CP1 L
                                                                                  CP1 L

                                       A                        A                                                          A                       A

                                                 Inhibit

           H                                                                      Gate H                                               Inhibit
Gate                                                                              input
input L                                                                                                                                n-3
                                                                               5  CP2 L       n
CP2

                                                                       4                               n-1
                                                 3
Count                                                                                                          n-2
                              2                                                   Count

                    1                                                                            0                                                    n-4
             0                                                                                                                                                 n-5
      0                                                                           Gate H
                                                                                  input L
Gate H                                                                            CP1

input         L

CP1                                                                                                                    A                        A

                                    A                     A

                                       Inhibit                                                                             Inhibit

Count

input H                                                                              Count H
                                                                                     input
CP2           L                                                                5 CP2 L n

Count                                                                    4                                 n-1
                                              2                 3                                                                 n-2

                             1                                                        Count                                                        n-3
                  0                                                                                                                                         n-4
         0                                                                                       0
                                                                                                                                                                   n-5

                 Up/Down A Command input mode                                                       Up/Down B Individual input mode

        H                                                                                 H
CP1                                                                               CP1

         L                                                                                 L

        H                              A                        A
CP2
                                    3                                                     H
         L                                      2                                 CP2

                           2                                                               L
                  1
Count 0                                                            2        3                               2       3      2                          2  3

                                                             1                                      1                                  11

                                                                                  Count 0

            Up/Down C Quadrature input mode                                       Note 1         A: Minimum signal width; B: Must be at least 1/2 of
                                                                                  Note 2         minimum signal width. Signals may not be counted
       H                                                                          Note 3         if the minimums for A and B are not met.
       L
                                                                                                 Set the same counting speed for CP1 and CP2 when
               BB BB                                                                             in Up/Down C mode.

       H                                                                                         H and L
       L

                                                                                         Signal No-voltage input                       Voltage input
                                                                                                                                       4.5 to 30 VDC
                                    3                                     3                   H             Short-circuit              0 to 2 VDC
                                                                   2
                                 2     2

Count            1                                        1                                   L             Open circuit
      0

14
H7BR                                                                                                      H7BR

  Input/Output Mode Setting

H7BR-B

Output 2 operation applies for 1-stage models only.

Output                                               Input mode
                                                        Down
mode                Up                                                                     Up/Down A.B.C

N

           Reset
         999,999
        Preset 2
        Preset 1

                 0

        Output 1

                    Output 2

             Outputs and present value display are maintained until reset.
F

                         Reset
                      999,999
                     Preset 2
                     Preset 1

                              0

        Output 1

                    Output 2

             Present value display runs continuously. Outputs are maintained until reset.
C

                         Reset
                      999,999
                     Preset 2
                     Preset 1

                              0

                    Output 1

                    Output 2

             Present value is placed in reset start status as soon as count up is reached. The count up is not displayed. Outputs are
             1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot period for Output 2.
             One-shot time periods for Output 1 and 2 are independent.
R

                         Reset

                      999,999
                     Preset 2

                     Preset 1

                              0

        Output 1

          Output 2

        Present value is placed in reset start status as soon as count up is reached. Outputs are 1-shot and operate repeatedly.
        Output 1 is self-holding, and goes off after expiration of the 1-shot period for Output 2. One-shot time periods for Output 1
        and 2 are independent.

                                                                                                                                        15
H7BR                                                                                                                  H7BR

Output                  Input mode
                           Down
mode                Up                                                                                 Up/Down A.B.C

K

           Reset
         999,999
        Preset 2

        Preset 1
                 0

        Output 1

                    Output 2

             Present value runs continuously. Output 1 is self-holding, and goes off after expiration of the 1-shot period for Output 2.
             One-shot time periods for Output 1 and 2 are independent.
P

                         Reset
                      999,999
                     Preset 2

                     Preset 1
                              0

        Output 1

                    Output 2

             Present value display does not change during 1-shot time period, but reset start status is returned to as soon as count is
             reached. Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot
             period for Output 2. One-shot time periods for Output 1 and 2 are independent.
Q

                         Reset

                      999,999
                     Preset 2

                     Preset 1

                              0

        Output 1

                    Output 2

             Present value runs continuously through 1-shot time period and returns to reset start status immediately afterward. Outputs
             are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot period for Output 2.
             One-shot time periods for Output 1 and 2 are independent.
A

                         Reset

                      999,999
                     Preset 2

                     Preset 1

                              0

        Output 1

          Output 2

        Present value and output 1 maintain status until reset. Output 1 and 2 operate independently.

16
H7BR                                                                                                                 H7BR

                          One-shot output from Output 1                        One-shot output from Output 2
                          Self-holding output                                  Self-holding output

                          One-shot outputs can be set to between 10 and 1,000 ms.

Batch Counter Operation

The batch counter counts the number of times set value is reached for 1-stage models, and the number of times set 2 is reached for 2-stage
models.

Batch count reset                                                              The batch count output holds until
                                                                               reset by the batch count reset.
  Batch count set                                                              The present value of the batch count
                value                                                          advances continuously.

Batch count present
                 value 0

           Batch output

1. The batch count present value remains at 0 while the batch   5. When power is interrupted and the batch count output is ON,
        count reset is ON.                                              the output will be ON when power returns.

2. When the batch count set value is 0, the batch count will    6. When a batch count set value which is greater than the
        proceed, but there will be no output.                           present value is changed to a set value which is less than the
                                                                        present value, the output will go ON.
3. When the batch count present value exceeds 9999, it returns
        to 0.                                                   7. If, after the output has gone ON, the set value is changed to a
                                                                        set value which is greater than the present value, the output
4. The batch count present value and output do not affect the           will remain ON.
        RESET Key or reset input.

H7BR-C

Output 2 operation applies for 1-stage models only.

Output                                                            Input mode
mode                                                           Up/Down A.B.C
K

        Comp.

                            Reset

                          999,999
                           Comp.

                             Set 2
                             Set 1

                                  0
                         -999,999

                        Output 1

                        Output 2

             Present value increments and decrements within displayable range. Outputs go ON for one-shot.
D

                           Comp.

                  Reset

                999,999
                 Comp.

                  Set 2
                  Set 1

                        0
               -999,999

              Output 1

              Output 2

        Present value increments and decrements within displayable range. Outputs are ON during the count is equal.

                                                                                                                     17
H7BR                                                                                                                     H7BR

Output                                                                  Input mode
mode                                                                 Up/Down A.B.C
L

        Comp.

                            Reset

                          999,999
                           Comp.

                             Set 2
                             Set 1

                                  0
                         -999,999

                        Output 1

                        Output 2

             Present value increments and decrements within displayable range. Output 1 is ON whenever present value is less than or
             equal to Set 1; Output 2 is ON whenever present value is greater than or equal to Set 2.
H

                           Comp.

                  Reset

                999,999
                 Comp.

                  Set 2
                  Set 1

                        0
               -999,999

              Output 1

              Output 2

        Present value increments and decrements within displayable range. Output 1 is ON whenever present value is greater than
        or equal to Set 1; Output 2 is ON whenever present value is greater than or equal to Set 2.

        Edge input   One-shot output                                                 One-shot outputs can be set to be-
        Level input  Instantaneous (equals) output                                   tween 10 and 1,000 ms.
                     Self-holding output/level input

Note:  1. Counting inputs are not applied while the reset input is
           ON.

       2. One-shot outputs, when ON, are turned OFF when the
           reset input goes ON.

       3. One-shot outputs, when ON, are left ON for the one-shot
           time period when the compensation input goes ON

       4. One-shot outputs, when ON, are reset and the one-shot
           output is restarted if a preset designating the output is
           reached.

       5. The compensation input is valid only when the present
           value is being incremented.
           The compensation input is also valid only for the
           H7BR-Cj.

18
H7BR                                                                                                                                        H7BR

Dimensions                                                                                                                           M3.5 terminal screw
                                                                                                                                     (effective length: 6 mm)
Note: All units are in millimeters unless otherwise indicated.
                                                                                                             100
H7BR                                                                                                                                           67.6

Flash Mounting

                                                                                                         72

                                                                             72

Flash Mounting Adapter

                                                                                                                 Panel                      7 + panel thickness

                                                                                                                                       100
                                                                                                             6

Panel Cutouts                                      100 min.

Panel cutouts are                        68  +0.7
as shown at right.                           0
(according to DIN43700).
                          68       +0.7
                                   0

                          82 min.

                                                                                                                                                                 19
H7BR                                                                                                                                                   H7BR

Installation

  Terminal Arrangement

H7BR-B (standard type)                                                      H7BR-C ( range type)

1 Stage, Contact and NPN                CP2 input                           1 Stage, Contact and NPN                CP2 input
                                            CP1 input
Transistor Outputs                                                          Transistor Outputs                            CP1 input
                                                 Gate input                 H7BR-C
H7BR-B                     Reset input                12/24 VDC             H7BR-CV                    Reset input        Gate input
H7BR-BV                            0V                        Output common
                                                                                                              0V               12/24 VDC
                                                                                                                                    Output common
                                                                                                           (-)
                                                                                                                                 (+)

                                    8 9 10 11 12 13 14                                                          8 9 10 11 12 13 14

                                    Sensor                                                                        Sensor

Batch count reset          15       (-) power supply (+)       17 Unused    Compensation input         15       (-) power supply (+)          17 Unused
                                                                             Key protection input
                                                          OUT                                                                         OUT

    Key protection input   16           OUT                    18                                      16           OUT                       18

                                                          Batch

                                    12 34 5 67                                                                  12 3 4 5 6 7

                                                                 Unused                                                                       Unused

                                             100 to 240 VAC/24 VAC                                                        100 to 240 VAC/24 VAC

                               ()      (+) 12 to 24 VDC                                                   ()      (+) 12 to 24 VDC

1 Stage, Contact and PNP                CP2 input                           1 Stage, Contact and PNP                CP2 input
                                            CP1 input                                                                   CP1 input
Transistor Outputs         Reset input                                      Transistor Outputs         Reset input
H7BR-BP                            0V            Gate input                                                    0V            Gate input
H7BR-BVP                                              12/24 VDC             H7BR-CP                                               12/24 VDC
                                                            Output common   H7BR-CVP                                                    Output common

                                    8 9 10 11 12 13 14                                                          8 9 10 11 12 13 14

                                        Sensor                                                                    Sensor
                           15 (-) power supply (+)
    Batch count reset                                          17 Unused    Compensation input         15       (-) power supply (+)          17 Unused
     Key protection input                                                    Key protection input
                                                          OUT                                                                         OUT

                           16           OUT                      18                                    16           OUT                       18
                                                          Batch

                                    123456 7                                                                    123456 7

                                                                 Unused                                                                       Unused

                                            100 to 240 VAC/24 VAC                                                   100 to 240 VAC/24 VAC

                               ()      (+) 12 to 24 VDC                                                   ()      (+) 12 to 24 VDC

2 Stages, Contact and NPN               CP2 input                           2 Stages, Contact and NPN               CP2 input
                                            CP1 input                                                                   CP1 input
Transistor Outputs         Reset input                                      Transistor Outputs         Reset input
                                   0V            Gate input                                                    0V            Gate input
H7BR-BW                                               12/24 VDC             H7BR-CW                                               12/24 VDC
H7BR-BWV                                                    Output common   H7BR-CWV                                                    Output common

                                    8 9 10 11 12 13 14                                                          8 9 10 11 12 13 14

                                    Sensor                OUT 1                                                   Sensor              OUT 1

    Batch counter reset    15       (-) power supply (+)         17         Compensation input         15       (-) power supply (+)          17
     Key protection input                                                    Key protection input
                                                          OUT 2                                                                       OUT 2

                           16           OUT 2 OUT 1              18                                    16           OUT 2 OUT 1               18

                                                          Batch

                                    123456 7                                                                    123456 7

                                                                                                                                      Unused

                                        100 to 240 VAC/24 VAC                                                       100 to 240 VAC/24 VAC

                               ()      (+) 12 to 24 VDC                                                   ()      (+) 12 to 24 VDC

20
H7BR                                                                                                                                                                                                                 H7BR

H7BR-B (standard type)                                                        H7BR-C ( range type)

2 Stages, Contact and PNP                CP2 input                            2 Stages, Contact and PNP                                                                           CP2 input
                                             CP1 input                                                                                                                                CP1 input
Transistor Outputs         Reset input                                        Transistor Outputs         Reset input
                                   0V             Gate input                                                     0V                                                                        Gate input
H7BR-BWP                                               12/24 VDC              H7BR-CWP                                                                                                          12/24 VDC
H7BR-BWVP                                                    Output common    H7BR-CWVP                                                                                                               Output common

                                         8 9 10 11 12 13 14                                                       8 9 10 11 12 13 14

                                        Sensor               OUT 1                                                Sensor                                                                            OUT 1
                           15 (-) power supply (+)                   17
Batch count reset                                                             Compensation input         15       (-) power supply (+)                                                              17
Key protection input                                                          Key protection input
                                                             OUT 2                                                                                                                                  OUT 2

                           16            OUT 2 OUT 1         18                                          16                                                                       OUT 2 OUT 1       18

                                                             Batch

                                         123456 7                                                                 123456 7

                                              100 to 240 VAC/24 VAC                                                                                                               Unused

                                              12 to 24 VDC                                                                                                                        100 to 240 VAC/24 VAC

                                    ()  (+)                                                                 ()                                                                  (+) 12 to 24 VDC

Note: Do not connect unused terminals.

  Connections

The inputs of the H7BR are no-voltage (short-circuit or open) inputs and voltage inputs.
(Key protection only for no-voltage inputs)

No-voltage Inputs                                           Voltage Output                        Contact Input

Open Collector                                                       Sensor

                            Sensor

      0 V for input
           Reset input
                 CP2 input
                      CP1 input
                            Gate input
                                  12/24-V output
                                                                      0 V for input
                                                                            Reset input
                                                                                 CP2 input
                                                                                       CP1 input
                                                                                            Gate input
                                                                                                  12/24-V output
                                                                                                                                      0 V for input
                                                                                                                                           Reset input
                                                                                                                                                 CP2 input
                                                                                                                                                       CP1 input
                                                                                                                                                            Gate input
                                                                                                                                                                  12/24-V output

*H: Transistor ON                             *H: Relay ON                    *H: Transistor ON

No-voltage Input Signal Levels

No-contact          1. High level
input               Transistor ON
                    Residual voltage: 2 V max.
Contact             Impedance when ON: 1 k max.
input
                    2. Low level
                    Transistor OFF
                    Impedance when OFF: 100 k max.

                    Use contacts which can adequate-
                    ly switch 2 mA at 5 V

                                                                                                                                                                                                                     21
H7BR                                                                                                                                                                                                       H7BR

Voltage Inputs                                                          PNP Transistor                               Contact Input

  NPN Transistor                                                                   Sensor

                                                            Sensor

    0 V for input
         Reset input
               CP2 input
                    CP1 input
                          Gate input
                                12/24-V output
                                                                    0 V for input
                                                                          Reset input
                                                                               CP2 input
                                                                                     CP1 input
                                                                                          Gate input
                                                                                                12/24-V output
                                                                                                                                    0 V for input
                                                                                                                                          Reset input
                                                                                                                                                CP2 input
                                                                                                                                                     CP1 input
                                                                                                                                                           Gate input
                                                                                                                                                                 12/24-V output

        *H: Transistor OFF                                              *H: Transistor ON         *H: Relay ON

Voltage Input Signal Levels

1. High level 4.5 to 30 VDC
2. Low level 0 to 2 VDC

Photoelectric  3-wire DC type(NPN)                                                                Photoelectric      3-wire DC type (PNP)
sensor                                                                                            sensor
               Output (black)                                                                                        Output (black)
   E3S-A/B     12 to 24 V (brown)                                                                   E3S-A/B          12 to 24 V (brown)

               0 V (blue)                                                                                            0 V (blue)

                                                                        8 9 10 11 12 13 14                                                                                           8 9 10 11 12 13 14

                                                                    15  Sensor                17                                                                                 15  Sensor                17

                                                                        (-) power supply (+)                                                                                         (-) power supply (+)

                                                                    16  H7BR-B, BV            18                                                                                 16  H7BR-BV               18

                                                                        123456 7                                                                                                     123456 7

*Models ending in -BV have reversed logic.

Photoelectric  Output (black)                                                   Using the external power supply      Output (black)
sensor         12 to 24 V (brown)                                                                                    12 to 24 V (brown)
                                                                                                          Proximity
   E3S-A/B                                                                                                sensor
                                                                                                          E2E-XjE

               0 V (blue)                                                                                            0 V (blue)

                                                                        8 9 10 11 12 13 14                                                                                           8 9 10 11 12 13 14

                                                                    15  Sensor                17                                                                                 15  Sensor                17

                                                                        (-) power supply (+)                                                                                         (-) power supply (+)

                                                                    16  H7BR-BV               18                                                                                 16  H7BR-B, BV            18

                                                                        123456 7                                                                                          123456 7

                                                                                                  *Models ending in -BV have reversed logic.

22
H7BR                                                                                                                     H7BR

Precautions                                                                Self-diagnostic Function

  Sensor Power Supply                                                    The following displays will appear if an error occurs. The present

The capacity of the external power supply is 160 mA at 12                  value and output enter the same status as after pressing the
                                                                             RESET Key.
    VDC/80 mA at 24 VDC switchable. When using a 24 VAC/12 to
    24 VDC power supply type H7BR, reduce the load with the              Display  Error               Output Correction Function
    power supply voltage, as shown in the following diagram (When
    supplying external power).                                                                        status             setting

                                                                         *        Present             No      Press      No
                                                                                  value               change
Load current (mA)  160                                       12 VDC               below min.                  RESET Key change

                                                                         ffffff** Present                     or reset
                                                                                                              input
                                                                                          value
                   80                                        24 VDC                       above max.

                                                                         e1       CPU                 OFF     Press

                                                                                                              RESET Key

                   20                                                    e2       Memory                                 Set at the
                                                                                                                         factory
                   10

                   0    10                     17        20  25          *Displayed when the present value has fallen below the min. value
                                                                         in the H7BR-C (range type).
                        Supply voltage (VDC)
                                                                         **Displayed when the present value has exceeded the max. value in
                                                                         the H7BR-C (range type).

  Power Supplies                                                         Operating Environment

When turning the power ON and OFF, input signal reception is            When using the Counter in an area with much electronic noise,

    possible, unstable, or impossible as shown in the diagram below.         separate the Timer, wiring, and the equipment which generates
    The unstable period will vary with power supply voltage, and the         the input signals as far as possible from the noise sources. It is
    load conditions on external power supplies.                              also recommended to shield the input signal wiring to prevent
                                                                             electronic interference.
Power                    ON
supply                  OFF                    10 ms         0 to 1.2 s   Organic solvents (such as paint thinner), as well as very acidic or
                                               Possible      impossible
Input                            0 to 50 ms                                  basic solutions might damage the outer casing of the Counter.

                                   impossible                            Using the Prescale Function

                                                              Unstable    When setting the prescale value, be sure that the set value

A switching regulator is used in the internal circuits of counters         satisfies this equation: set value "max. value - prescale value'. (if
                                                                             the prescale value is 1,250, 999.999 - 1,250 = 998.749 max.)
    with 100-to-240-VAC or 12-to-24-VAC specifications, causing
    an inrush current (approx. 1.5 A) to flow when power is turned on.    If a higher value is used, the output may be affected, so make
    If the capacity of the power supply to the counter is insufficient,
    the counter may not start operation. Be sure to provide adequate         sure that the output is produced before starting operation.
    capacity (recommended supply capacity; 25 W min.)
                                                                         Changing Set Values
Connect the power supply voltage through a relay or switch in
                                                                         When changing the set value while the Counter is operating, the
    such a way that the voltage reaches a fixed value immediately.
                                                                             output will be produced if the set value ever equals the present
  DIP Switch Setting Changes                                                 value. To avoid triggering the output, begin by incrementing a
                                                                             higher digit to a large number.
Any changes in the DIP switch settings while power is being sup-
plied is invalid. Restart the power supply.                                Resetting with a Set Value of 0

                                                                         When resetting is performed with the set value set to "0," no

                                                                             output will be given for the safety reasons once the reset is
                                                                             turned OFF (except for the H7BR-C).

                                                                                                                                23
H7BR                                                                                                                        H7BR

  Output Delay                                                            Max. Count Speed of Batch Counter

The following table shows the delay from when the present value       The maximum count speed of the batch counter is 1 kHz {cps}.

    passes the set value until the output is produced. (The delay is        The batch counter counts the number of count-up times at the
    the result of output control time, signal transmission time, relay      last stage (i.e., the number of preset-value counts if the H7BR is
    switching time, etc.)                                                   a one-stage model and the number of SET2 preset-value counts
                                                                            if the H7BR is a two-stage model). An interval of 1 ms or more is
Actual measurements in N and K modes.                                       required before the batch counter counts up again after it has
                                                                            counted up.
    Control output  Max. counting          Output delay*
                         speed                                            Response Delay Time for Resetting
                                                                        (Transistor Output)
Contact output 1, 2 30 Hz {cps}            18 to 24 ms
                                                                         Take the following output delays into consideration after the
                    1 kHz {cps}            4.7 to 5.8 ms
                                                                            reset signal input is turned ON and the output is turned OFF.
                    5 kHz {cps}            4.4 to 5.4 ms

                    10 kHz {cps}           4.3 to 5.3 ms                   Minimum reset     Output delay
                                                                             signal width          time
Transistor output 1, 2 30 Hz {cps}         13.5 to 20 ms
                                                                        1 ms               0.8 to 1.2 ms
                    1 kHz {cps}            0.59 to 0.81 ms
                                                                        20 ms              15 to 25 ms
                    5 kHz {cps}            0.29 to 0.44 ms

                    10 kHz {cps}           0.24 to 0.36 ms                Other

Batch outputs       30 Hz {cps}            13.6 to 20.2 ms               When the Counter is installed in a control box and tests are

                    1 kHz {cps}            0.72 to 0.94 ms                  conducted which may damage the Counter's internal circuitry
                                                                            (for example, a test measuring the maximum voltage difference
                    5 kHz {cps}            0.42 to 0.57 ms                  between the control circuit and metal components), remove the
                                                                            Counter from the control box or short-circuit the terminals.
                    10 kHz {cps}           0.37 to 0.49 ms

*The variation in delays is due to different modes and conditions.
For systems where the delay is a problem, take actual measure-
ments under operating conditions.

               ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
               To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. M009-E1-01D In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

Industrial Control Components Division                                                                     Printed in Japan
Shiokoji Horikawa, Shimogyo-ku,                                                                            0103-0.5C (1190)
Kyoto, 600-8530 Japan
Tel: (81)75-344-7119/Fax: (81)75-344-7149

24
                                                                 Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability
WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                             Application Considerations
SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
   equipment, and installations subject to separate industry or government regulations.

Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

                                                                        Disclaimers
CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased product.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.

This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

Cat. No. M009-E1-01D                                                                                                                                   2007. 3
                               In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
                                                      (c)Copyright OMRON Corporation 2007 All Rights Reserved.
Industrial Automation Company

http://www.ia.omron.com/
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved