H5CX-ASD-N-DC12-24-AC24

器件型号:H5CX-ASD-N-DC12-24-AC24
器件类别:机电产品    工业自动化    计时器   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Timers Scrw TermTrans OUT Multi-Fnc

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Timers
RoHS:YES
产品:
Product:
Digital Timer
Timing Range:0.001 s to 9999 hr
Display Type:4 Digit LCD Backlight
电流额定值:
Current Rating:
100 mA
封装:
Packaging:
Bulk
系列:
Series:
H5CX-N
端接类型:
Termination Style:
Screw
商标:
Brand:
Omron Automation and Safety
工作电源电压:
Operating Supply Voltage:
12 V to 24 V
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
H5CXASDNDC1224/AC24 H5CXASDNDC1224AC24
单位重量:
Unit Weight:
4.056506 oz

H5CX-ASD-N-DC12-24-AC24器件文档内容

        New Product

     Digital Timer

     H5CX-@-N

Ultra-compact Timer Provides Advanced

Functions and Security Settings.

Basic Features

• Short body with depth of only 59 mm (for 24-VAC / 12 to 24-VDC Models with

     Screw Terminals). *1

• Character height of 12 mm for better readability (on models with 4 digits).

• The present value display characters can be switched between red, green,

     and orange. *2

Safety and Reliability

• Power supply circuit and input circuits are isolated for safety and reliability. *3

• New set value limit and output counter functions have been added.

Other Features

• Front Panel can be changed to white or light gray. *4

• Models with instantaneous contact output added to the series.

*1.     For 100 to 240 VAC Models with Screw Terminals 78 mm, Models with Sockets: 63.7 mm

        (case dimension).

*2.     The H5CX-A11, H5CX-L8 and H5CX-B Timers have only red characters.                                                                    Refer to “Safety Precautions” on page 41.

*3.     Specifications: 100 to 240 VAC

*4.     Replacement Front Panels sold separately.

Features

Basic Features                                                                                     Safety and Reliability

Ultra Short Body                                                                                   Isolated Power Supply and Input Circuits *1

The body depth has been greatly reduced. Helps in making thinner                                   Power supply circuit and input circuits are isolated for safety and

control panels. (Models with Screw Terminals)                                                      reliability.

     24-VAC / 12 to 24-VDC Models with Screw Terminals: 59 mm                                      Previous non-isolated timers had wiring restrictions and could be damaged if

     100 to 240-VAC / VDC Models with Screw Terminals: 78 mm *                                     wired incorrectly. The New H5CX removes these worries.

     Models with Sockets: 63.7 mm (case dimension)                                                                                           Output terminal on PLC

     *  The shortest body for a timer with isolated power supply and input circuits and a maximum                  Previous                  or other device

                                                                                                                   H5CX      Input terminal

        ambient temperature of 55°C (according to OMRON investigation in June 2009).                    AC power

                                                                                                        supply *2            0-V terminal

                                                                                                                                             COM terminal

                                                                                                                                                                               Forget These

                                                                                                                                                                               Worries with the

                                                                                                                                             –V                            +V  New H5CX

                                                         Previous                                                                            Stabilized DC

                                        New     models   models                                                                              power supply

                                                                                                   *2. The AC power supply ground is on the commercial power supply side.

Easier to Read                                                                                     *1.  New Models (H5CX-@-N) with 100 to 240-VAC specifications.

For better readability, the character height for the present value display

is 12 mm (on models with 4 digits), the largest class in the industry. The                         Set Value Limit

wide viewing angle and brightness provide excellent visibility.                                    You can set an upper limit for the set value to prevent unexpected

The number of display segments has also been increased to make                                     operation of output devices caused by setting mistakes.

settings easier to understand, and the present value display can be

switched between red, green and orange so that output status can be

seen from a distance.                                                                                                                      Worry-free operation

Model with 4 Digits        Model with 6 Digits                                                                                             is achieved with the

                                                                                                                                           New H5CX by

                                                                                                                                           restricting the time

        12 mm              10 mm                                                                                                           that can be set.

        (actual size)      (actual size)            New  Previous

                                                   models models

                                                                                                   Output Counter

               (Display example)                                                                   The output counter counts the number of times the output turns ON

                                                Easy to read from the top, bottom, and sides!      (alarm display, count monitoring, count in increments of 1,000). This

Note:   The H5CX-A11 and H5CX-L8                Timers have only red characters.                   counter is useful in managing the service life of the Timer or the load.

The Easiest Operation

Operation is simplified by the                  Model with 4 Digits  Model with 6 Digits

Up/Down Keys for each digit

on 4-digit models and Up Keys

for each digit on 6-digit

models.

                                                                                                                                                                                                 1
   H5CX-@-N

   Other Features

   Change the Front Panel Color                                                    Universal NPN/PNP Input

   The Front Panel can be replaced with an optional Front Panel (order             DC 2-wire sensors can be connected for a wide range of input

   separately) with a different color to match the installation site. Select       devices.

   from black, white, and light gray.                                              Waterproof, Dust-proof Structure (UL508 Type

                                                                                   4X and IP66)

                                                                                   Worry-free application is possible in locations subject to water.

                                                                                   Note:      When the Y92S-29 Waterproof Packing is used.

                                                                                   Key Protection

               Black                   White                   Light gray          Select from any of seven protection patterns. Use the best one for the

               (standard)

                                              You can replace                      application.

                                              the Front Panel.                     New Modes

   Models with Instantaneous Contact Output                                        Modes, such as a stopwatch mode (Mode S), have been added.

   Models with instantaneous contact outputs have been added to the                Select any of 15 modes.

   lineup for use with self-holding circuits and as auxiliary relays. These

   models are also convenient when replacing analog timers.

   Model Number Structure

   Model Configuration

                                                                                   H5CX Series

                                              Standard Type                        Economy Type                         Six-digit Type

                                              H5CX-A Series                        H5CX-L Series                        H5CX-B Series

   Type

   Model                               H5CX-A@-N                H5CX-A11@-N        H5CX-L8@-N           H5CX-L8E@-N     H5CX-B@-N

               Timer                                   Yes                                        Yes                                       No

   Function    Twin timer                              Yes                                        Yes                                       No

               Two-stage settings/                     No                                         No                                        Yes

               forecast output

                                                                                                       Timer Mode

   Operating modes                                     Timer Mode: 11 modes                             : 4 modes       Timer Mode: 2 modes

                                                       Twin Timer Mode: 4 modes                        Twin Timer Mode

                                                                                                        : 2 modes

   Input                                       NPN/PNP input                       NPN input                None        NPN/PNP input

   External connections                Screw terminal            11-pin socket                8-pin socket              Screw terminal block

                                       block

   Present value display               Red, green, or                                                       Red

   character color                     orange

   Number of display digits                                                     4                                                           6

   Instantaneous contacts                                        None                                       Provided                        None

   Gate input                                     Supported                        Not supported                        Supported

   DIP switch settings                                 Provided                                   None                  Provided

   Power supply voltage                                    100 to 240 VAC or 24 VAC/12 to 24 VDC                        12 to 24 VDC

2
                                                                                                                                                           H5CX-@-N

Model Number Legend                          (Not         all  possible combinations of functions are available.)

H5CX- @– @– @– @– @– -N
           1  2  3   4  5

1.  Type Classifier                                             2.  External Connections                                       3.    Settings

   Symbol               Meaning                                    Symbol                     Meaning                          Symbol                     Meaning

    A                Standard type                                  None            Screw terminals                                  None                 One stage

    B                   6-digit type                                    8           8-pin socket                                     W                    Two stages

    L                Economy type                                     11            11-pin socket

4.  Output type                                                 5.  Supply voltage

   Symbol               Meaning                                    Symbol                     Meaning

    None   Contact output (time-limit SPDT)                         None        100 to 240 VAC 50/60 Hz

    E            Contact output (time-limit                           D         12 to 24 VDC/24 VAC 50/60 Hz *

              SPDT + instantaneous SPDT) *                      *  The H5CX-BWSD-N is available only for 12 to 24 VDC.

    S                Transistor output

*  Can be used as a time-limit DPDT output.

Ordering Information

List of Models

    Type      Time specifications            Operating modes                    External               Inputs           Outputs            Supply voltage             Models

                                                                                connections

                                                                                                                        Contact output     100 to 240 VAC  H5CX-A-N

                                                                                                                        (time-limit        12 to 24 VDC/   H5CX-AD-N

                                             Timer Mode                                                                 SPDT)              24 VAC

                                             A: Signal ON Delay I               Screw terminals                                            100 to 240 VAC  H5CX-AS-N

                                             A-1: Signal ON Delay II                                                    Transistor         12 to 24 VDC/

                                             A-2: Power ON Delay I                               Signal, Reset,         output (SPST)      24 VAC          H5CX-ASD-N

   H5CX-A                                    A-3: Power ON Delay II                              Gate (NPN/

                                             b: Repeat cycle 1                                   PNP inputs)            Contact output     100 to 240 VAC  H5CX-A11-N

                                             b-1: Repeat cycle 2                                                        (time-limit        12 to 24 VDC/

                                             d: Signal OFF Delay                                                        SPDT)              24 VAC          H5CX-A11D-N

           0.001 to 9.999 s                  E: Interval                        11-pin socket

           0.01 to 99.99 s                   F: Cumulative                                                              Transistor         100 to 240 VAC  H5CX-A11S-N

           0.1 to 999.9 s                    Z: ON/OFF-duty-adjustable flicker                                          output (SPST)      12 to 24 VDC/

           1 to 9999 s                       S: Stopwatch                                                                                  24 VAC          H5CX-A11SD-N

           1 s to 99 min 59 s                Twin Timer Mode                                                                               100 to 240 VAC  H5CX-L8-N

           0.1 to 999.9 min                  toff: Flicker OFF Start 1                                                  Contact output

           1 to 9999 min                     ton: Flicker ON Start 1                                                    (time-limit        12 to 24 VDC/   H5CX-L8D-N

           1 min to 99 h 59 min              toff-1: Flicker OFF Start 2                         Signal, Reset          SPDT)              24 VAC

           0.1 to 999.9 h                    ton-1: Flicker ON Start 2                           (NPN inputs)                              100 to 240 VAC  H5CX-L8S-N

           1 to 9999 h                                                                                                  Transistor

                                                                                                                        output (SPST)      12 to 24 VDC/   H5CX-L8SD-N

                                                                                                                                           24 VAC

   H5CX-L                                    Timer Mode                         8-pin socket

                                             A-2: Power ON Delay I                                                      Contact output     100 to 240 VAC  H5CX-L8E-N

                                             b: Repeat cycle 1                                                          (time-limit SPDT

                                             E: Interval                                                                + instantaneous

                                             Z: ON/OFF-duty-adjustable flicker                   None                   SPDT)

                                             Twin Timer Mode                                                            Models with        12 to 24 VDC/

                                             toff: Flicker OFF Start 1                                                  instantaneous      24 VAC          H5CX-L8ED-N

                                             ton: Flicker ON Start 1                                                    contact outputs

           0.01 to 9999.99 s                                                                     Signal, Reset,

   H5CX-B  1 s to 99 h 59 min 59 s           A: Signal ON Delay I               Screw terminals  Gate (NPN/             Transistor         12 to 24 VDC    H5CX-BWSD-N

           0.1 to 99999.9 min                F-1: Cumulative                                     PNP inputs)            output (DPST)

           0.1 to 99999.9 h

Note: 1.   The functions that are provided depend on the model. Check detailed specifications                           before ordering.

       2.  Refer to page 33 and later for information on H5CX-B Timers (6-digit display).

                                                                                                                                                                              3
   H5CX-@-N

   Accessories (Order Separately)

   Front Panels (Replacement Parts)

             Models               Color               Applicable Timers              Page

             Y92P-CXT4G  Light gray (5Y7/1)

             Y92P-CXT4S  White (5Y9.2 / 0.5)           Four-digit models             12

             Y92P-CXT4B  Black (N1.5)

   Note: 1.  You can change the color of the front panel when mounting the   Timer.  The Timer  is  shipped  with  a  black  (N1.5)  Front  Panel.

   2.        "TIMER" is printed on the front of Replacement Front Panels.

   Soft Cover

             Models                           Remarks                                Page

             Y92A-48F1                           ---                                 12

   Hard Cover

             Models                           Remarks                                Page

             Y92A-48                             ---                                 12

   Flush     Mounting    Adapter

             Models                           Remarks                                Page

             Y92F-30     Included with models with terminal blocks.

                         Use this Adapter to install the Timer in a cutout           12

             Y92F-45     previously made for a DIN 72 x 72 mm device

                         (panel cutout: 68 x 68 mm).

   Waterproof Packing

             Models                           Remarks                                Page

             Y92S-29     Included with models with terminal blocks.                  12

   Connection Sockets

             Models               Type                Connectable    Timers                         Remarks                                 Page

             P2CF-08     Front Connecting

                         Socket

                         Front Connecting             H5CX-L8@               Round crimp terminals cannot be used on Finger-safe

             P2CF-08-E   Socket                                              Sockets. Use forked crimp terminals.

                         (Finger-safe Type)

             P2CF-11     Front Connecting

                         Socket                                                                                                             13

                         Front Connecting             H5CX-A11@              Round crimp terminals cannot be used on Finger-safe

             P2CF-11-E   Socket                                              Sockets. Use forked crimp terminals.

                         (Finger-safe Type)

             P3G-08                                   H5CX-L8@               A Y92A-48G Terminal Cover can be used with the

                         Back Connecting Socket                              Socket to create a finger-safe construction.

             P3GA-11                                  H5CX-A11@

   Terminal Covers for P3G-08 and P3GA-11 Back-connecting Sockets

             Models                           Remarks                                Page

             Y92A-48G                            ---                                 14

4
                                                                                                                                   H5CX-A@-N/-L@-N

               H5CX-A@-N/-L@-N Digital Timers

   • Switch the display color* between red, green, and orange

     to see the output status from a distance.

   • Up/Down Keys for each digit enable easy operation.

   • Cyclic control is easy with the Twin Timer and Variable

     ON/OFF Duty modes.

*  Not supported by the H5CX-A11@ or H5CX-L8@.

Specifications

Ratings

   Item                    Models                   H5CX-A@-N                                      H5CX-A11@-N                                  H5CX-L8@-N

   Classification                  Standard Type                                                                                 Economy Type

            Power supply           • 100 to 240 VAC 50/60 Hz

            voltage *1             • 12 to 24 VDC/24 VAC 50/60 Hz

   Ratings  Operating voltage      85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC)

            fluctuation range

            Power consumption      Approx. 6.2 VA at 100 to 240 VAC, Approx. 5.1 VA/2.4 W at 24 VAC/12 to 24 VDC *2

   Mounting method                 Flush mounting                                   Flush mounting, surface mounting, DIN track mounting

   External connections            Screw terminals                                  11-pin socket                                8-pin socket

   Degree of protection            IEC IP66, UL508 Type 4X (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used

   Digits                          4 digits

   Time ranges                     0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s ti 99 min 59 s

                                   0.1 m to 999.9 min, 1 min to 9999 min, 1 min to 99 h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h

   Timer mode                      Elapsed time (Up), remaining time (Down) (selectable)

                                                                                                                                 Signal, Reset

            Input signals          Signal, Reset, Gate                                                                           (no inputs on models with instantaneous

                                                                                                                                 contact outputs)

                                   No-voltage Input     ON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)                No-voltage Input

   Inputs                                               ON residual voltage: 3 V max.                                            ON impedance: 1 kΩ max.

            Input method                                OFF impedance: 100 kΩ min.                                                  (Leakage current: 12 mA when 0 Ω)

                                   Voltage Input        High (logic) level: 4.5 to 30 VDC                                        ON residual voltage: 3 V max.

                                                        Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)         OFF impedance: 100 kΩ min.

                                   No-voltage input/voltage input (switchable)

            Signal, reset, gate    Minimum input signal width: 1 or 20 ms (selectable, same for all input)

   Reset system                    Power reset (depending on output mode), external reset, manual reset, automatic reset (depending on output mode)

   Power reset                     Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1, and toff-1 mode)

   Reset voltage                   10% max. of rated supply voltage

   Sensor waiting time             250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)

                                   A: Signal ON Delay I, A-1: Signal ON Delay II, A-2: Power ON Delay I, A-3: Power ON           Models with Instantaneous Contact

                                   Delay II, b: Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal OFF Delay, E: Interval, F:        Outputs

            Output modes           Cumulative, Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, toff: Flicker OFF Start 1,       A-2: Power ON Delay I, b: Repeat Cycle 1,

                                   ton: Flicker ON Start 1, toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2               E: Interval, Z: ON/OFF-duty-adjustable

                                                                                                                                 flicker, toff: Flicker OFF Start 1, ton:

   Output                                                                                                                        Flicker ON Start 1

            One-shot output        0.01 to 99.99 s

            time

                                   • Models with Contact Outputs

                                   5 A at 250 VAC/30 VDC, resistive load (cos =1)

            Control output         Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)

                                   • Transistor output: NPN open collector,

                                   100 mA at 30 VDC max., residual voltage: 1.5 VDC max. (Approx. 1 V), Leakage current: 0.1 mA max.

                                   7-segment, negative transmissive LCD;

                                   Present value: 12-mm-high characters,            7-segment, negative transmissive LCD;

   Display method *3                                (switchable between red,        Present value: 12-mm-high characters, red

                                                    green, and orange)              Set value:      6-mm-high characters, green

                                   Set value:       6-mm-high characters,

                                                    green

   Memory backup                   EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.

   Operating temperature range     -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)

   Storage temperature range       -25 to 70°C    (with no icing or condensation)

   Operating humidity range        25% to 85%

   Case color                      Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light gray or white.)

   Attachments                     Waterproof packing, flush mounting               Label for DIP switch settings                                    ---

                                   adapter, label for DIP switch settings

*1.  Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for DC power.

*2.  Inrush current will flow for a short time when the power supply is turned ON.

     Inrush Current (Reference Values)

               Voltage           Applied voltage     Inrush current (peak value)            Time

     100 to 240 VAC                264 VAC                     5.3 A                        0.4 ms

     12 to 24 VDC/24 VAC           26.4 VAC                    6.4 A                        1.4 ms

                                   26.4 VDC                    4.4 A                        1.7 ms

*3.  The display is lit only when the power is ON. Nothing is displayed when power is OFF.

                                                                                                                                                                            5
   H5CX-A@-N/-L@-N

   Characteristics

                                       Power-ON start: ±0.01% ±50 ms max. (See note 1.)                           Life-test Curve (Reference

                                       Signal start: ±0.005%±0.03 ms max. (See note 1.)                           Values)

      Accuracy of operating time       Signal start for transistor output model: ±0.005%±3 ms max. (See note

      and setting error (including     1 and 2.)                                                                  Switching operations (× 104)

      temperature and voltage          If the set value is within the sensor waiting time at startup the control                                1,000

      influences)                      output of the H5CX will not turn ON until the sensor waiting time passes.                                500

                                       Note:  1.  The values are based on the set value.

                                              2.  The value is applied for a minimum pulse width of 1 ms.

                                       100 MΩ min. (at 500 VDC) between current-carrying terminal and

      Insulation resistance            exposed non-current-carrying metal parts, and between non-continuous

                                       contacts                                                                                                 100

                                       2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and                                   50        DC30V L/R=7ms

                                       non-current-carrying metal parts                                                                                                   AC250V/DC30V

                                       2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits                                                              cosφ =1

                                       for H5CX-A11-N/-A11S-N

      Dielectric strength              1,000 VAC, 50/60 Hz for 1 min between control output, power supply,

                                       and input circuits for H5CX-@SD-N                                                                        10

                                       2,000 VAC, 50/60 Hz for 1 min between control output, power supply,                                             AC250V  cosφ =0.4

                                       and input circuits for other models                                                                      0      1       2  3       4        5

                                       1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts                                                                         Load  current  (A)

                                       3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12      A maximum current of 0.15 A can be switched at

      Impulse withstand voltage        to 24 VDC                                                                  125 VDC (cosφ =1) and a maximum current of 0.1

                                       4.5 kV (between current-carrying terminal and exposed non-current-         A can be switched if L/R is 7 ms. In both cases, a

                                       carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC    life of 100,000 operations can be expected.

                                       ±1.5 kV (between power terminals) and ±600 V (between input

      Noise immunity                   terminals), square-wave noise by noise simulator (pulse width: 100 ns/

                                       1 µs, 1-ns rise)

      Static immunity                  Malfunction: 8 kV

                                       Destruction: 15 kV

                          Destruction  10 to 55 Hz with 0.75-mm single amplitude each in three directions for

      Vibration                        2 h each

      resistance          Malfunction  10 to 55 Hz with 0.35-mm single amplitude each in three directions for

                                       10 min each

      Shock               Destruction  300 m/s2 in three directions, three cycles

      resistance          Malfunction  100 m/s2 in three directions, three cycles

                          Mechanical   10,000,000 operations min. (under no load at 18,000 operations/h and

      Life                             ambient temperature of 23°C)

      expectancy          Electrical   100,000 operations min. (5 A at 250 VAC, resistive load at 1,800

                                       operations/h and ambient temperature of 23°C) *

      Weight                           Approx. 115 g (Timer only)

   *  Refer to Life-test  Curve.

6
                                                                                                                              H5CX-A@-N/-L@-N

Applicable Standards

                                 UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14 *1,

                                 conforms to EN61812-1 (Pollution degree 2/overvoltage category III)

Approved safety standards        B300 PILOT DUTY

                                 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 5 A resistive load

                                 VDE0106/P100

                                 CCC: Pollution degree 2, Overvoltage category II *2

                                 (EMI)                                  EN61812-1

                                 Emission Enclosure:                    EN55011 Group 1 class A

                                 Emission AC mains:                     EN55011 Group 1 class A

                                 (EMS)                                  EN61812-1

                                 Immunity ESD:                          EN61000-4-2: 6 kV contact discharge (level 2)

                                                                                           8 kV air discharge (level 3)

EMC                              Immunity RF-interference:              EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level          3);

                                                                                           10 V/m (Pulse-modulated, 900 MHz   5 MHz) (level 3)

                                 Immunity Conducted Disturbance:        EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)

                                 Immunity Burst:                        EN61000-4-4: 2 kV power-line (level 3);

                                                                                           1 kV I/O signal-line (level 4)

                                 Immunity Surge:                        EN61000-4-5: 1 kV line to lines (power and output lines) (level 3);

                                                                                           2 kV line to ground (power and output lines) (level 3)

                                 Immunity Voltage Dip/Interruption:     EN61000-4-11: 0.5 cycle, 100% (rated voltage)

*1.  The following safety standards apply to models with sockets (H5CX-A11@ or H5CX-L8@).

     cUL (Listing): Applicable when an OMRON P2CF (-E) Socket is used.

     cUR (Recognition): Applicable when any other socket is used.

*2.  Excluding the H5CX-ASD-N/-A11SD-N/-L8SD-N.

I/O Functions

For details, refer to the timing charts on page 20 and page 29.

           Start signal          Normally functions to start timing.

                                 In modes A-2 and A-3, disable timing. In mode S, starts and stops timing.

                                 • Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode,

Inputs *1  Reset                        the present value returns to the set value.)

                                 • Count inputs are not accepted and control output turns OFF while reset input is ON.

                                 • Reset indicator is lit while reset input is ON.

           Gate *2               Disables timing. (If a reset occurs while the gate input is ON, a reset will be performed.)

Outputs    Control output (OUT)  Outputs take place according to designated operating mode when timer reaches corresponding set value.

*1.  The H5CX-L8E@ does not have an input.

*2.  The H5CX-L@ does not have a gate input.

Response Delay Time When Resetting (Transistor Output)

The following table shows the delay from when the reset signal is input until the output is turned OFF.

                                                                   (Reference value)

     Minimum reset signal width                 Output delay time

           1 ms                                   0.8 to 1.2 ms

           20 ms                                  15 to 25 ms

                                                                                                                                                        7
   H5CX-A@-N/-L@-N

   Connections

   Block Diagram

                                                                (Basic insulation)  Power supply

                                         Output circuit                                 circuit

                                         (Basic insulation)                         (See note.)

                                                                                              Display circuit

                              Input circuits                    Internal control

                                                                circuit

                                                                                        Key switch circuit

   Note: Basic insulation is provided between the power supply circuit                                            and  the  input circuits. However, basic insulation is not provided in the

         H5CX-@D-N.

   Terminal Arrangement

   Confirm that the power supply meets specifications before use.

                                                             H5CX-A-N/-AD-N                                                                                                 H5CX-AS-N/-ASD-N

                   Reset   Signal        Gate                                                                                          Reset    Signal        Gate

         0V                                                                                                                    0V

              6    7       8             9                                                                                          6  7        8             9

              1    2       3             4          5                                                                               1  2        3             4          5

                           Contact output                       Terminals 1 and 6 of the H5CX-AD-N                                            Transistor output

                                                                                                                                                                                         Terminals 1 and 6 of the H5CX-ASD-N

         (-)          (+)                                       are connected internally.                                      (-)         (+)                                           are connected internally.

                                                        H5CX-A11-N/-A11D-N                                                                                                  H5CX-A11S-N/-A11SD-N

         Reset                                                                                                                 Reset

         Signal                                                                                                                Signal

         Gate                                                Internal circuit                                                  Gate                                            Internal circuit

                                   5     6     7                                                                                                        5     6     7

              Unused       4                        8                                                                               Unused      4                        8

                 0V        3                         9                                                                                 0V       3                        9

                              2                   10            Contact                                                                            2                   10                Transistor

                                      1     11                  output                                                                                     1     11                      output

                          Unused                                                        Terminals 2 and 3 of the                              Unused                                                      Terminals 2 and 3 of the

                                                                                        H5CX-A11D-N are                                                                                                   H5CX-A11SD-N are

                                                                                        connected internally.                                                                                             connected internally.

                              (-)              (+)                                                                                                 (-)              (+)

                                                           H5CX-L8-N/-L8D-N                                                                                                 H5CX-L8S-N/-L8SD-N

                                                             Internal circuit                                                                                                  Internal  circuit

         Signal                                                                                                                Signal                                  Unused

         Reset                     4           5                                                                               Reset                    4           5

                           3                        6                                                                                           3                        6

                                                                Contact                                                                                                                  Transistor

                           2                        7           output                                                                          2                        7               output

                                   1           8                                                                                                        1           8

                           0V                                                                                                                   0V

                                                                Terminals 1 and 2 of the H5CX-L8D-N                                                                                      Terminals 1 and 2 of the H5CX-L8SD-N

                                   (-)         (+)              are connected internally.                                                               (-)         (+)                  are connected internally.

                                                        H5CX-L8E-N/-L8ED-N                                                  Transistor Output

                 Internal circuit                               Internal circuit                                            •  The transistor output of                                  NPN      Output               PNP Output

                                                  4     5                                                                      the H5CX is insulated

                                            3                6                                                                 from the internal circuitry

   Instantaneous                                                                  Time-limit                                   by a photocoupler, so the

   contact output                           2                7                 contact output

   OUT1                                                                           OUT2                                         transistor output can be

                                                  1     8                                                                      used as both NPN and                                                       Load               Load

                                                                                                                               PNP output.                                                           +                                  +

                                                                                                                                                                                                  Power for load             Power for load

                                                  (–)   (+)                                                                 •  The diode connected to                                                Timer

   Note: Do not connect unused terminals as relay terminals.                                                                   the collector of the output

                                                                                                                               transistor is used to

                                                                                                                               absorb inverted voltage

                                                                                                                               that is generated when an                                                                     Inductive

                                                                                                                                                                                                                  +          load

                                                                                                                               inductive load is

                                                                                                                               connected to the H5CX.                                                     Power   for  load

8
                                                                                                                                                                                                                                                                                                                                                                    H5CX-A@-N/-L@-N

Input Circuits

Signal, Reset, and Gate Input

No-voltage Inputs (NPN Inputs)                                                                                                              Voltage Inputs (PNP Inputs)

                     +14 V

               1 kΩ

                                        Internal                                                                                                      Approx. 4.7 kΩ                                       Internal

IN                                      circuit                                                                                             IN                                                             circuit

Input Connections

The inputs are no-voltage (closed or open) inputs or voltage inputs except for the H5CX-L8@.                                                                                                                                                                                                                    (The            inputs                          of  the H5CX-L8@ are no-voltage                                                                                      inputs

only. The H5CX-L8E@ does not have an input.)

No-voltage Inputs (NPN Inputs)

Open Collector                                                                                                                  Voltage Output                                                                                               Contact Input                                                                                                          DC Two-wire Sensor

       PLC or                                                                                                                               Sensor

       sensor

                        0 V for inputs     Reset input                  Signal input               Gate input                                             0 V for inputs     Reset input     Signal input     Gate input                                                                        0 V for inputs     Reset input     Signal input     Gate input                                                  0 V for inputs                Reset input              Signal input     Gate input

    H5CX-A@          6                  7               8                             9                                                     H5CX-A@    6                  7               8                9                                                 H5CX-A@                         6                  7               8                9                  H5CX-A@                        6                            7                          8                         9

    H5CX-A11@        3                  7               6                             5                                                     H5CX-A11@  3                  7               6                5                                                 H5CX-A11@                       3                  7               6                5                  H5CX-A11@                      3                            7                          6                         5

    H5CX-L8@         1                  3               4                             -                                                     H5CX-L8@   1                  3               4                -                                                 H5CX-L8@                        1                  3               4                -                  H5CX-L8@                       1                            3                          4                         -

    Note: Operate with transistor ON                                                                                                        Note: Operate with transistor ON                                                                                 Note: Operate with relay ON                                                                            Note: Operate with transistor ON

No-voltage Input Signal Levels                                                                                                                                                                                                                                                                                                                                      Applicable Two-wire Sensor

                     Short-circuit level Transistor ON                                                                                                                                                                                                                                                                                           •  Leakage current: 1.5 mA max.

                     • Residual voltage: 3 V max.                                                                                                                                                                                                                                                                                                •  Switching capacity: 5 mA min.

                     • Impedance when ON: 1 kΩ max.                                                                                                                                                                                                                                                                                              •  Residual voltage: 3.0 VDC max.

No-contact              (The leakage current is approx. 12 mA when the                                                                                                                                                                                                                                                                           •  Operating voltage: 10 VDC

input                   impedance is 0 Ω.)

                     Open level Transistor OFF

                     • Impedance when OFF: 100 kΩ min.

Contact input        Use contacts which can adequately switch 5 mA at 10                                                                                                                                   V

Note:  The DC voltage must be 30 VDC max.

Voltage Inputs (PNP Inputs)                                                                                                                 The inputs of the H5CX-L8@ are                                                                      no-voltage inputs only.

No-contact Input (NPN Transistor)                                                                                                                      No-contact Input (PNP                                                                    Transistor)                                                        Contact Input

               Sensor                                                                                                                                                                     Sensor

                                                        0 V for inputs                Reset input              Signal input     Gate input                                                                                   0 V for inputs     Reset input     Signal input     Gate input                                                                                     0 V for inputs     Reset input                  Signal input               Gate input

           H5CX-A@                         6                            7                          8                         9                                               H5CX-A@                                      6                  7               8                9                                                                                 H5CX-A@      6                  7               8                             9

           H5CX-A11@                       3                            7                          6                         5                                               H5CX-A11@                                    3                  7               6                5                                                                                 H5CX-A11@    3                  7               6                             5

           Note: Operate with transistor OFF                                                                                                                              Note: Operate with transistor ON                                                                                                                                                      Note: Operate with relay ON

Voltage Input Signal Levels

High level (Input ON): 4.5 to 30 VDC

Low level (Input OFF): 0 to 2 VDC

Note:  1.      The DC voltage must be 30 VDC max.

       2.      Input resistance: Approx. 4.7 kΩ

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    9
H5CX-A@-N/-L@-N

Nomenclature

                 Display Section                                                                                            Operation Key

1.  Key Protect Indicator (orange)                                                                   4      8. Mode Key

2.  Control Output Indicator (orange)                                                                       (Changes modes and setting items)

                                                                                                     5      9. Reset Key

3.  Reset Indicator (orange)                                  1                                      6      (Resets present value and output)

4.  Present Value Display (Main display)                      2                                             10. Up Keys 1 to 4

    (Character height: 12 mm, red *)                          3                                      7

    * Characters on models with screw terminals               8                                      10     11. Down Keys 1 to 4

    (H5CX-A@) can be switched between red,                                                           11

    green, and orange.                                        9

5.  Time Unit Indicators                                                                                                           Switches

    (Color is same as present value display.)                                    Front  View                12. Key-protect Switch

    (If the time range is 0 min, 0 h, 0.0 h, or 0 h

    0 min, these indicators flash to indicate                                                               (Default  setting)     OFF                 ON

    timing operation.)                                        12                                                                (Disabled)          (Enabled)

                                                                                                     13

6.  Set Value Display (Sub-display)

    (Character height: 6 mm, green)

7.  Set Value 1, 2 Indicator (green)

    Character Size      Character Size                                                                      13. DIP Switch

    for Present         for Set Value                                                                       ON

    Value Display       Display

                                                                                                            OFF       1  2      3  4  5  6  7    8

    12mm                   6mm                                                                              Note: There is no DIP switch            on the

                                                                                                                      H5CX-L8@.

Dimensions                                                                                                                                             (unit:  mm)

Digital Timers

Digital Timers

H5CX-A-N/-AS-N (Flush Mounting Models)                                                  H5CX-AD-N/-ASD-N    (Flush Mounting Models)

    48×48               6                      78                                             48×48      6      59

                                                           44.8×44.8                                                                  44.8×44.8

                    Note: M3.5 terminal screw        (effective length:  6  mm)                      Note: M3.5 terminal screw (effective length: 6 mm)

H5CX-A11@-N                                                                             H5CX-L8@-N (Flush Mounting/Surface Mounting Models)

(Flush Mounting/Surface Mounting                     Models)

    48×48               6               63.7         14.4

                                                                                              48×48      6      63.7                  14.2

                                                           44.8×44.8

                                                                                                                                            44.8×44.8

10
                                                                                                               H5CX-A@-N/-L@-N

Dimensions with Flush      Mounting Adapter

H5CX-A-N/-AS-N (Provided   with Adapter and Waterproof Packing)                                             Panel Cutouts

                                                                                                            Panel cutouts areas      shown below.             (according

                                Y92S-29 (provided)      Panel  Y92F-30 (provided)                           to DIN43700).

                                Waterproof                     Flush Mounting Adapter                                                            60 min.

                                Packing

                                                                                                                                        45+00.6

                                                                                                                            45+00.6

                  58                     (51)

                                                                                                                         15 min.

                                                                                                               60 min.

                            48              7.5                76.5                                         Note: 1.     The mounting panel thickness

                                                                                                                         should be 1 to 5 mm.

                                                                                                               2.        To allow easier operation, it is

H5CX-AD-N/-ASD-N  (Provided with Adapter and Waterproof Packing)                                                         recommended that Adapters

                                                                                                                         be mounted so that the gap

                                Y92S-29 (provided)      Panel  Y92F-30 (provided)                                        between sides with hooks is at

                                Waterproof                     Flush Mounting Adapter                                    least 15 mm (i.e., with the

                                Packing                                                                                  panel cutouts separated by at

                                                                                                                         least 60 mm).

                                                                                                               3.        It is possible to mount Timers

                                                                                                                         side by side, but only in the

                  58                     (51)                                                                            direction without the hooks.

                                                                                                                         (However, if Timers are

                                                                                                                         mounted side by side, water

                                                                                                                         resistance will be lost.)

                            48              7.5                57.5                                                      n Units mounted side-by-side

                                                                                                                                        A

H5CX-A11@-N  (Adapter  and  Waterproof Packing Ordered Separately)                                                             A=(48n-2.5)  +1

                                                                                                                                            –0

                                                                                                                         With Y92A-48F1 attached.

                                                                                                                         A={48n-2.5+(n-1)×4}              +1

                            Y92S-29 (order separately)  Panel  Y92F-30 (order separately)                                                                 –0

                            Waterproof Packing                 Flush Mounting Adapter                                    With Y92A-48 attached.

                                                                                           P3GA-11 (order                A  =  (51n  -  5.5)     +1

                                                                                           separately)                                           –0

                                                                                           Back-connecting  Dimensions with Front

                                                                                           Socket

                                                                                                            Connecting Socket

                  58                     (51)

                                                                                                                                     H5CX

                                                                                                                      *              -A11@-N

                                                                                                                      103.2                               100.9

                            48              7.5                      89.9

H5CX-L8@-N  (Adapter  and  Waterproof Packing Ordered Separately)

                                                                                                                      P2CF-11(-E) (order separately)

                            Y92S-29 (order separately)  Panel  Y92F-30 (order separately)                             Front Connecting Socket

                            Waterproof Packing                 Flush Mounting Adapter      P3G-08 (order

                                                                                           separately)

                                                                                           Back-connecting

                                                                                           Socket

                                                                                                                      *              H5CX

                                                                                                                      92.3           -L8@-N                   90

                  58                     (51)

                                                                                                                      P2CF-08(-E) (order separately)

                                                                                                                      Front Connecting Socket

                            48              7.5                      84.8                                   *  These dimensions vary with the type of             DIN  track

                                                                                                               (reference value).

                                                                                                                                                                              11
H5CX-A@-N/-L@-N

Accessories (Order Separately)

    Note:                                                                   Soft Cover                              Hard Cover

    Depending on the operating environment, the condition of                Y92A-48F1                               Y92A-48

    resin products may deteriorate, and may shrink or become

    harder. Therefore, it is recommended that resin products are

    replaced regularly.

Front Panel (Replacement Part)

You can change the color of the front panel when mounting the Timer.        Protecting the Timer in Environments Subject to Oil

The Timer is shipped with a black (N1.5) Front Panel.

Y92P-CXT4S                                                                  The H5CX's panel surface is water-resistive (IP@6, UL Type 4X)

Cover for Timer with 4 Digits                                               and so even if drops of water penetrate the gaps between the keys,

White (5Y9.2/0.5)                                                           there will be no adverse effect on internal circuits. If, however, there

                                                                            is a possibility of oil being present on the operator's hands, use the

Y92P-CXT4G                                                                  Soft Cover. The Soft Cover ensures protection equivalent to IP54

Cover for Timer with 4 Digits                                               against oil. Do not, however, use the H5CX in locations where it

Light gray (5Y7/1)                                                          would come in direct contact with oil.

Y92P-CXT4B                                                                  Flush Mounting           Adapter

Cover for Timer with 4 Digits                                               Y92F-30                        Y92F-45

Black (N1.5)

                                                                            Order the Flush                Use this Adapter

Replacement Method                                                          Mounting Adapter               to install the

                                        The Front Panel is attached to      separately if it is            Timer in a cutout

                                        the Terminal with tabs in four      lost or damaged.               previously made

                                                                            Note:  A Flush                 for a DIN 72 x 72

                                        locations. To remove the Front             Mounting                mm device

                                                                                   Adapter is              (panel cutout:

                                        Panel, open the tabs and pull the          included with

                                        Front Panel forward.                       models with             68 x 68 mm).

                                                                                   screw

                                        To attach the Front Panel, press           terminals.

Tabs                                    it onto the Timer so that all four

                               Grooves  tabs lodge into the groves on the   Waterproof            Packing

                                        body of the Timer.                  Y92S-29                           Order the Waterproof Packing

                                                                            Note:  The                        separately if it is lost or damaged.

                                                                                   Waterproof                 The Waterproof Packing can be used

                                                                                   Packing is                 to achieve IP66 protection.

                                                                                   included with

                                                                                   models with

                                                                                   screw

                                                                                   terminals.

                                                                            The Waterproof Packing will deteriorate, harden, and shrink

                                                                            depending on the application environment. To ensure maintaining the

                                                                            IP@6, UL Type 4X waterproof level, periodically replace the

                                                                            Waterproof Packing. The periodic replacement period will depend on

                                                                            the application environment. You must confirm the proper

                                                                            replacement period. Use 1 year or less as a guideline. If the

                                                                            Waterproof Packing is not replaced periodically, the waterproof level

                                                                            will not be maintained.

                                                                            It is not necessary to mount the Waterproof Packing if waterproof

                                                                            construction is not required.

12
                                                                                                                                                                                          H5CX-A@-N/-L@-N

Connection Sockets

Front-connecting Sockets

Model                                                                           Dimensions                                                                Terminal arrangement               Mounting hole

                                                                                                                                                          and internal connections           dimensions

P2CF-08                                                                                                                                  20.3 max.

                                                                                50 max.

                                    Two, 4.5-dia. holes

                                                                                                                   70 max.                          35.4

                                                                                                               4

                                                                                                                                                          6           5            4      3

                                                                                                         7.8                                                                                 Two, M4 or 4.5-dia. holes

                            Eight, M3.5 x 7.5 sems            screws                                                                  3             4.5

P2CF-08-E                                                                                                                                21.5 max.                                           40±0.2

(Finger Safe Terminal)                                                       50 max.                                                     20.3

                                                                                                                                                                                             Note: The Socket can

                                                                                40±0.2                                                   19                                                  also be mounted

                                                                                                                                                          7           8            1      2

                                                                                                                                                                   (Top         View)        to DIN track.

                            Two, 4.5-dia. holes                   6          5          4        3                              3

                                                                  P2CF-08-E

                                                                                                               70  max.        1.3                  35.4

                                                                     10A250VAC

                                                                     RESISTIVE

                                                                  7          8          1        2         4

                            Eight,  M3.5  x  7.5  set  screws                                         7.8                          5                4.5

P2CF-11                                                              50 max.                                                             31.2 max.

                            Two, 4.5-dia. holes

                                                                                                               70 max.                              35.4

                                                                                                           4                                              8           7            6      5

                                                                                                                                                                                          4  Two, M4 or 4.5-dia. holes

                        Eleven, M3.5 x 7.5 sems   screws                                            7.8                      3                      4.5

P2CF-11-E                                                            50 max.                                                        31.2 max.                                                40±0.2

(Finger Safe Terminal                                                40±0.2                                                              30                                                  Note: The Socket can

Type)                                                                                                                                                     9                               3

                                                       8      7                 6             5                                                           10          11           1      2  also be mounted

                            Two, 4.5-dia. holes                                                                          3                                         (Top         View)        to DIN track.

                                                                  P2CF-11-E

                                                                                           4

                                                                                                           70  max.     1.2                         35.4

                                                           9                               3

                                                                  10A250VAC

                                                                  RESISTIVE

                                                       10     11                1             2       4

                        Eleven, M3.5 x 7.5 set screws                                            7.8                        5                       4.5

Note: Round crimp terminals cannot be used on Finger-safe Sockets.                                                      Use     forked crimp terminals.

Back-connecting Sockets

Model                                                                           Dimensions                                                                Terminal arrangement

                                                                                                                                                          and internal connections

P3G-08                                                            27 dia

                                                                                                                                                                   3      4     5     6

                                             45

                                                                                                                                                                   2      1     8     7

                                                                     45                             4.9            17                                     (Bottom               View)

P3GA-11                                                           27 dia

                                                                                                                                                                      5      6  7     8

                                                                                                                                                                   4

                                             45                                                                                 25.6

                                                                                                                                                                   3                  9

                                                                                                                                                                      2      1  11    10

                                                                     45                             4.5                         6.2                       (Bottom               View)

                                                                                                                  16.3

Note: A Y92A-48G  Terminal  Cover   can be        used with                     the        Socket          to     create       a finger-safe        construction.

                                                                                                                                                                                                                        13
H5CX-A@-N/-L@-N

Terminal Covers for P3G-08 and P3GA-11 Back-connecting Sockets

    Model                                                       Dimensions

    Y92A-48G                              Twelve, 6.4 dia

                              34  Y92A-48G     UP          47.7×47.7              48×48

                                                P  C

                                                               16.5  24.6

                                                                           27.6

                                          47.4

Note: The Terminal Cover can  be used with a Back-mounting Socket (P3G-08 or P3GA-11) to create a finger-safe construction.

Optional Products             for Track Mounting

Mounting Track

PFP-100N                                                                                                                             7.3±0.15

PFP-50N                                   4.5

                                                                                                                                     35±0.3        27±0.15

                                                      15   25   10    25                   25  10      25              15 (5) *                    1

                                                                           1,000 (500)  *                        *     The values shown in     parentheses are  for  the  PFP-50N.

Mounting Track                                                                                                                                 16

PFP-100N2                                 4.5

                                                                                                                       35±0.3    27  24               29.2

                                                   15      25   10    25                   25  10  25       15                           1            1.5

                                                                           1,000

End Plate                                                                                      10

PFP-M                                                                                                  6.2       1.8

                                                          M4 x 8 pan

                                                          head screw

                                                                                                         1

                                                       50                                                        35.5  35.3

                                                                                                            1.8

                                                          11.5

                                                                      10                               1.3

                                                                           M4 spring washer            4.8

Spacer                                                                                             16

PFP-S                                                                 5                            12

                                                                                        44.3                     34.8

                                                                                                   16.5

Note: Order Spacers in increments of 10.

14
                                                                                                                          H5CX-A@-N/-L@-N

Operating Procedures                                                                                                                               Timer

Setting Procedure Guide

Settings for Timer Operation *

Use the following settings.

Settings for Twin Timer Operation *

Refer to page 25.

* It is not necessary to mount the Waterproof Packing if waterproof construction is not required.

Operating Procedures for Timer Function

Step1              Settings for basic functions can be performed with just the DIP switch.

                   Note: There is no DIP switch on the H5CX-L8@. Go to                   Step2      .

                   Key-protect Switch

                                                                          Be sure to set pin 1 to ON when     using  the  DIP switch.

                                                                 ON

                                                                 OFF   1  2  3  4  5  6  7  8

                   Item                         OFF              ON                         Pin 2      Pin 3         Pin 4             Time range

1           DIP switch settings                 Disabled  Enabled                              ON      ON            ON                0.001 s to 9.999 s

2                                                                                              OFF     OFF           OFF               0.01 s to 99.99 s

3           Time range                          Refer to the table on                          ON      OFF           OFF               0.1 s to 999.9 s

                                                     the right.                                                                        1 s to 9999 s

4                                                                                              OFF     ON            OFF

5                                               Refer to the table on                          ON      ON            OFF    0 min 01 s to 99 min 59 s

            Output modes                             the right.                                OFF     OFF           ON         0.1 min to 999.9 min

6

7           Timer mode                          UP        DOWN                                 ON      OFF           ON     0 h 01 min to 99 h 59 min

8           Input signal width                  20 ms            1 ms                          OFF     ON            ON                0.1 h to 999.9 h

Note:  All  the pins are factory-set  to  OFF.

                                                                                            Pin 5      Pin 6                Output mode

Be sure to turn ON pin 1 of the DIP switch.                                                                   Mode A: Signal ON delay 1

Changes to DIP switch settings are enabled when the                                            OFF     OFF    (Timer resets when power comes ON.)

power is turned ON.                                                                            ON      OFF    Mode A-2: Power ON delay 1

(Set the DIP switch while the power is OFF.)                                                                  (Timer resets when power comes ON.)

                                                                                               OFF     ON     Mode E: Interval

                                                                                                              (Timer resets when power comes ON.)

                                                                                                              Mode F: Cumulative

                                                                                               ON      ON     (Timer does not reset when power

                                                                                                              comes ON.)

After making DIP switch settings for basic operation, advanced functions can be added using the operation keys on the front panel. Refer to

Step2  on page 16 for details.

                                                                                                                                                           15
H5CX-A@-N/-L@-N

Timer

       Step2                       Settings that cannot be performed with the DIP switch are performed with the operation                                                           keys.

    •  Change to Function Setting Mode.

                                   Power ON                                       For details on operations in run mode, refer to page 19.

                                                 3 s min.       *1

                                   Run mode             Function setting mode

                                                 3 s min.       *2

                              *1.  If the mode is switched to the function setting mode during operation, operation will continue.

                              *2.  Changes made to settings in function setting mode are enabled for the first time when the mode is changed to                        run mode.

                                   Also, when settings are changed, the timer is reset (time initialized and output turned OFF).

                                                                    The characters displayed in reverse video are the default settings.

                                                                    When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).

                                                                    If pin 1 of the DIP switch is set to ON, the setting items indicated in                 will not be displayed.

                                                                    Set the time range using the                   keys.

                                                 Time range                                                                                                                         Time Range       List

                                                                               s                    s         s            ……                     h                    s            Display          Set Value

                                                                    For details, refer to the Time Range List.                                                                                       0.01 s to 99.99 s

                                                                                                                                                                                                     (default setting)

                                                 Timer mode         Set the timer mode using the                   keys.                                                                             0.1 s to 999.9 s

                                                                    up                down                                                                                                           1 s to 9999 s

                                                                    (UP)             (DOWN)

                                                                                                                                                                                                     0 min 01 s to

                                                                    Set the output mode using the                  keys.                                                                             99 min 59 s

                                                                                                                                                                                                     0.1 min to

                                                 Output modes       a          a-1    a-2              a-3    b            b-1          d    e           f    z           s                          999.9 min

                                                                    (A)        (A-1)  (A-2)            (A-3)  (b)          (b-1)    (d)      (E)         (F)  (Z)      (S)                           1 min to

                                                                    Note: Only modes A-2, b, E, and Z can be selected for models             with    instantaneous                                   9999 min

                                                                       contact outputs.

                                                                    Set each digit for the output time using the corresponding                                keys.                                  0 h 01 min to

                                                                                                                                                                                                     99 h 59 min

       Function setting mode                     Output time        hold              0.01~ 99.99                                                                                                    0.1 h to 999.9  h

                                                                    (Output hold) (0.01s)      (99.99s)

                                                                    (If the output time is set to 0.00, hold is displayed.)                                                                          1 h to 9999 h

                                                                    Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.

                                                                                                                                                                                                     0.001 s to

                                                                    Set the input signal width using the                   keys.                                                                     9.999 s

                                                 Input signal

                                                                    20ms              1ms

                                                                    (20ms)            (1ms)

                                                                    Note: Not displayed for models with instantaneous contact outputs.

                                                 NPN/PNP            Set the NPN/PNP mode using the                         keys.

                                                 input

                                                                    npn               pnp

                                                                    (NPN input)   (PNP input)

                                                                    Note: Only displayed for the H5CX-A@ and H5CX-A11@.

                                                                    Set the display color using the                keys.

                                                 Display color

                                                                    red               grn             org     r-g          g-r             r-o                o-r         g-o       o-g

                                                                    (Red)             (Green)       (Orange)  (Red-green)  (Green-red)     (Red-orange)  (Orange-red)  (Green-orange)(Orange-green)

                                                                    Note: Displayed only for models with terminal screws (H5CX-A@).

                                                 Instantaneous/     Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)

                                                 time-limit         using the                  Keys.

                                                                    1c1c              2c

                                                                    (Instantaneous)   (Time-limit)

                                                                    Note: Displayed only for models with instantaneous contact outputs.

       From next page              To next page

16
                                                                                                                                            H5CX-A@-N/-L@-N

                                                                                                                                                                               Timer

From previous                To previous

                       page  page

                                              Set value      Set  the digits for the set  value limit using the corresponding    keys.

                                              upper limit

                                                                  1       9999

Function setting mode                                             (1)     (9999)

                                              Key protect    Set  the key protect level   using the  keys.

                                              level

                                                                  kp-1    kp-2            kp-3       kp-4         kp-5           kp-6       kp-7

                                                                  (KP-1)  (KP-2)          (KP-3)     (KP-4)       (KP-5)         (KP-6)     (KP-7)

                                          *1

                                              Output ON                                   *1. Set each digit for  the output time using the corresponding               keys.

                                              count alarm

                                              set value/                                  • Models without        Instantaneous Contact Outputs

                                              monitor value

                                                                                                                  Output ON              0         ~        9999

                                                                                                                  count alarm

                                                                                                                  set value      (0 x 1000 times)  (9999 x 1000 times)

                                                                                                                  Output ON

                                                                                                                  count monitor  Note: The monitor value is only displayed.

                                                                                                                  value                  It cannot be set.

                                                                                          •  Models  with  Instantaneous Contact Outputs

                                                                                                                  Instantaneous

                                                                                                                  output 1               0         ~        9999

                                                                                                                  (OUT1) ON

                                                                                                                  count alarm    (0 x 1000 times)  (9999 x 1000 times)

                                                                                                                  set value

                                                                                                                  Instantaneous

                                                                                                                  output 2               0         ~        9999

                                                                                                                  (OUT2) ON

                                                                                                                  count alarm    (0 x 1000 times)  (9999 x 1000 times)

                                                                                                                  set value

                                                                                                                  Instantaneous

                                                                                                                  output 1

                                                                                                                  (OUT1) ON      Note: The monitor value is only displayed.

                                                                                                                  count monitor          It cannot be set.

                                                                                                                  value

                                                                                                                  Instantaneous

                                                                                                                  output 2

                                                                                                                  (OUT2) ON      Note: The monitor value is only displayed.

                                                                                                                  count monitor          It cannot be set.

                                                                                                                  value

                                                                                                                                                                               17
H5CX-A@-N/-L@-N

Timer

Explanation of Functions

Operating Procedures for Timer Function

Items marked with stars () can be set using the DIP switch.

Time Range (timr)                                                         Display Color (colr)

Set the range to be timed in the range 0.001 s to 9,999 h.                 (Terminal block model: H5CX-A@ only)

Settings of type ---- h (9,999 h) and ---- min (9,999 min) cannot be       Set the color used for the present value.

made with the DIP switch. Use the operation keys if these settings are                                 Output OFF                     Output ON

required.

Timer Mode (timm)                                                         red                                        Red (fixed)

Set either the elapsed time (UP) or remaining time (DOWN) mode.            grn                                        Green (fixed)

In UP mode, the elapsed time is displayed, and in DOWN mode, the           org                                        Orange (fixed)

remaining time is displayed.                                               r-g                         Red                            Green

Output Mode (outm)                                                        g-r                         Green                          Red

Set the output mode.                                                       r-o                         Red                            Orange

The possible settings are A, A-1, A-2, A-3, b, b-1, d, E, F, Z and S.      o-r                         Orange                         Red

Only output modes A, A-2, E, and F can be set using the DIP switch.        g-o                         Green                          Orange

Use the operation keys if a different setting is required.

(For details on output mode operation, refer to "Timing Charts" on         o-g                         Orange                         Green

page 20.)                                                                  Key Protect Level (kypt)

Output Time (otim)                                                         Set the key protect level.

When using one-shot output, set the output time for one-shot output        Refer to “Key Protect Level” on page 32.

(0.01 to 99.99 s).                                                         Instantaneous/Time-limit (otmd)

One-shot output can be used only if the selected output mode is A,         Set the contact output to time-limit SPDT + instantaneous SPDT or

A-1, A-2, A-3, b, b-1 or S.                                                time-limit SPDT operation.

If the output time is set to 0.00, hold is displayed, and the output is

held.                                                                      Set Value Upper Limit (sl-h)

Input Signal Width (iflt)                                                 Set the upper limit for the set value when it is set in Run Mode.

Set the minimum signal input width (20 ms or 1 ms) for signal, reset,      The limit can be set to between 1 and 9999.

and gate inputs.                                                           This setting does not apply to the ON duty in Z mode.

The same setting is used for all external inputs (signal, reset, and gate  Output ON Count Alarm Set Value (on-a)

inputs).                                                                   Set the alarm value for the output ON count.

If contacts are used for the input signal, set the input signal width to   The limit can be set to between 0 x 1000 (0 times) and 9999 x 1000

20 ms.                                                                     (9,999,000 times). Only the underlined values are set. The alarm will

Processing to eliminate chattering is performed for this setting.          be disabled if 0 is set.

NPN/PNP Input Mode (imod)                                                  If the total ON count of the output exceeds the alarm set value, e3 will

Select either NPN input (no-voltage input) or PNP input (voltage           be displayed on the Timer to indicate that the output ON count alarm

input) as the input format.                                                value was exceeded. Refer to “Self-diagnostic Function” on page

Set an NPN input when using a 2-wire sensor.                               32 for information on the e3 display.

For details on input connections, refer to "Input Connections" on          ON Count Alarm Set Values for Outputs 1 and 2 (OUT1

page 9.                                                                    and OUT2) (on1a and on2a)

                                                                           Set the ON count alarm values for the outputs 1 and 2.

                                                                           The limit can be set to between 0 x 1000 (0 times) and 9999 x 1000

                                                                           (9,999,000 times). Only the underlined values are set. The alarm will

                                                                           be disabled if 0 is set.

                                                                           If the total ON count of instantaneous output 1 or 2 exceeds the alarm

                                                                           set value, e3 will be displayed on the Timer to indicate that the output

                                                                           ON count alarm value was exceeded. Refer to “Self-diagnostic

                                                                           Function” on page 32 for information on the e3 display.

                                                                           Output ON Count Monitor Value (on-c)

                                                                           The monitor value is only displayed. It cannot be set.

                                                                           The output ON count will be 1,000 times the displayed value.

                                                                           ON Count Monitor Values for Outputs 1 and 2 (OUT1 and

                                                                           OUT2) (on1c and on2c)

                                                                           The monitor value for output 1 or 2 is only displayed. It cannot be set.

                                                                           The output ON count will be 1,000 times the displayed value.

18
                                                                                                                       H5CX-A@-N/-L@-N

                                                                                                                                                        Timer

Operation in Run Mode

Operating Procedures for Timer Function

                                  Present value        Set each digit for the output time using the corresponding      keys.

                                  Set value

                                                       Note: H5CX-L8E@-N Precautions

                                                               Set the Timer’s set value before using the Timer in  a  self-holding circuit.

When Output Mode Z Is Selected

                                                       Set each digit for the output time using the corresponding      keys.

                                  Present value        (The               keys for the 4th digit cannot be used.)

                                  ON duty ratio

                                  Present value        Set each digit for the output time using the corresponding      keys.

                                  Cycle time

Present Value and Set Value

These items are displayed when the power is turned ON. The present

value is displayed in the main display and the set value is displayed

in the sub-display.

The values displayed will be determined by the settings made for the

time range and the timer mode in function setting mode.

Present Value and ON Duty Ratio (Output Mode = Z)

The present value is displayed in the main display and the ON duty

ratio is displayed in the sub-display. Set the ON duty ratio used in ON/

OFF-duty-adjustable flicker mode (Z) as a percentage.                                                                  Elapsed cycle time

ON time = Cycle time x     ON duty ratio (%)                                                                           ON duty set as a percentage

                                  100

The output accuracy will vary with the time range, even if the ON duty                                                 Up/Down keys used for analog

ratio setting is the same. Therefore, if fine output time adjustment is                                                adjustment of the ON duty

required, it is recommended that the time range for the cycle time is

set as small as possible.

Examples: 1. When Time Range = - - - - s (9999 s)                                                  Cycle time                                 Close     Open

                           31(%)                                                      ON duty (%)

    20(s) x                100    = 6.2(s)                                Control output

    Rounded off to the nearest integer (because                of  the                                                                        Opening/  Fully closed↔

                                                                                                                              closing valve             Fully open

    time range setting) → ON time = 6 s                                                                                                       ON duty   0%↔100%

2.  When Time Range = - -. - - s (99.99 s)

    20.00(s) x             31(%)  = 6.200(s)

                           100

    Rounded off to 2 decimal places (because of the time

    range setting) → ON time = 6.20 s

If a cycle time is set, cyclic control can be performed in ON/OFF-duty-

adjustable flicker mode simply by changing the ON duty ratio.

Present Value and Cycle Time (Output Mode = Z)

The present value is displayed in the main display and the cycle time

is displayed in the sub-display. Set the cycle time.

                                                                                                                                                                       19
H5CX-A@-N/-L@-N

Timer

Timing Charts

Operating Procedures for Timer Function

Models without Instantaneous Contact Outputs

The gate input is not included in the H5CX-L8@ models.                                                 Either  one-shot  output  or  sustained  output  can  be  selected.

    Mode A: Signal ON delay 1 (Timer resets when power comes ON.)

    Basic operation                                          Detailed operation

                                                                                       Power

    Power

                                                                                   Start signal

    Start signa*l

           input           Timing                                                      Gate

    Output

                                                                                       Reset

    * Start signal input is disabled during timing.                                                 t                                           t

    Timing starts when the start signal goes ON.                   Control output

    While the start signal is ON, the timer starts when the        Timing diagram

    power comes ON or when the reset input goes OFF.                               Set value

    The control output is controlled using a sustained or                          UP

    one-shot time period.                                                                0

    Note:  Output is instantaneous when setting is 0.                              Set value

                                                                                   DOWN

                                                                                         0

    Mode A-1: Signal ON delay 2 (Timer resets when power comes ON.)

    Basic operation                                          Detailed operation

                                                                                       Power

           Power

                                                                                   Start signal

    Start signal

           input           Timing                                                      Gate

    Output

                                                                                       Reset

    Timing starts when the start signal goes ON, and                                                t

    resets when the start signal goes OFF.

    While the start signal is ON, the timer starts when the        Control output

    power comes ON or when the reset input goes OFF.               Timing diagram

    The control output is controlled using a sustained or                          Set value

    one-shot time period.                                                          UP

                                                                                         0

    Note:  Output is instantaneous when setting is 0.                              Set value

                                                                                   DOWN

                                                                                         0

    Mode A-2: Power ON delay 1 (Timer resets when power comes ON.)

    Basic operation                                          Detailed operation

                                                                                       Power

    Power                                                                          Start signal

                           Timing

    Output                                                                             Gate

    Timing starts when the reset input goes OFF.                                       Reset

    The start signal disables the timing function (i.e.,

    same function as the gate input).                                                            t

    The control output is controlled using a sustained or          Control output

    one-shot time period.                                          Timing diagram

    Note:  Output is instantaneous when setting is 0.                              Set value

                                                                                   UP

                                                                                         0

                                                                                   Set value

                                                                                   DOWN

                                                                                         0

    Mode A-3: Power ON delay 2 (Timer does not reset         when power comes ON.)

    Basic operation                                          Detailed operation

                                                                                       Power

    Power                                                                          Start signal

                           Timing

                                   Sustained

    Output                                                                             Gate

    Timing starts when the reset input goes OFF.                                       Reset

    The start signal disables the timing function (i.e.,

    same function as the gate input).                                                            t                       t                      t

    The control output is controlled using a sustained or          Control output

    one-shot time period.                                          Timing diagram

    Note:  Output is instantaneous when setting is 0.                              Set value

                                                                                   UP

                                                                                         0

                                                                                   Set value

                                                                                   DOWN

                                                                                         0

20
                                                                                                            H5CX-A@-N/-L@-N

                                                                                                               Timer

Mode b: Repeat cycle 1 (Timer resets when power comes ON.)

Basic operation                                                Detailed operation

                                                               Sustained Output

Power                                                                              Power

Start signa*l                                                                  Start signal

       input   Timing        Timing     Timing         Timing

Output                                                                             Gate

* Start signal input is disabled during timing.                                    Reset

Timing starts when the start signal goes ON.

The status of the control output is reversed when time         Control output

is up (OFF at start).                                          Timing diagram

While the start signal is ON, the timer starts when the                        Set value

power comes ON or when the reset input goes OFF.                               UP

Note:  Normal output operation will not be possible if                               0

       the set time is too short.                                              Set value

       Set the value to at least 100 ms (contact                               DOWN

       output type).                                                                 0

                                                               One-shot Output

Power                                                                              Power

Start signa*l                                                                  Start signal

       input   Timing        Timing     Timing         Timing

Output                                                                             Gate

* Start signal input is disabled during timing.                                    Reset

Timing starts when the start signal goes ON.                                                       t  t

The control output is turned ON when time is up.               Control output

While the start signal is ON, the timer starts when the        Timing diagram

power comes ON or when the reset input goes OFF.                               Set value

Note:  Normal output operation will not be possible if                         UP

       the set time is too short.                                                    0

       Set the value to at least 100 ms (contact                               Set value

       output type).                                                           DOWN

                                                                                     0

Mode b-1: Repeat cycle 2 (Timer does not reset when power comes                              ON.)

Basic operation                                                Detailed operation

                                                               Sustained Output

Power                                                                              Power

Start signa*l                                                                  Start signal

       input   TimingTiming  Sustained  Timing Timing  Timing

Output                                                                             Gate

* Start signal input is disabled during timing.

                                                                                   Reset

Timing starts when the start signal goes ON.

The status of the control output is reversed when time

is up (OFF at start).                                          Control output

While the start signal is ON, the timer starts when the        Timing diagram

power comes ON or when the reset input goes OFF.                               Set value

                                                                               UP

Note:  Normal output operation will not be possible if                               0

       the set time is too short.                                              Set value

       Set the value to at least 100 ms (contact                               DOWN

       output type).                                                                 0

                                                               One-shot Output

Power                                                                              Power

Start signa*l                                                                  Start signal

       input   TimingTiming Sustained TimingTiming     Timing

Output                                                                             Gate

* Start signal input is disabled during timing.

                                                                                   Reset

Timing starts when the start signal goes ON.                                                       t  t  t  t  t

The control output is turned ON when time is up.

While the start signal is ON, the timer starts when the        Control output

power comes ON or when the reset input goes OFF.               Timing diagram

Note:  Normal output operation will not be possible if                         Set value

       the set time is too short.                                              UP

                                                                                     0

       Set the value to at least 100 ms (contact                               Set value

       output type).                                                           DOWN

                                                                                     0

                                                                                                                             21
H5CX-A@-N/-L@-N

Timer

    Mode d: Signal OFF delay (Timer resets when power comes ON.)

    Basic operation                                        Detailed operation

                                                                                                                   Power

       Power

                                                                                                               Start signal

    Start signa*l

       input                      Timing                                                                           Gate

       Output

*   Start signal   input  is  enabled during      timing.                                                          Reset

The control output is ON when the start signal is ON                                           Control output

(except when the power is OFF or the reset is ON).                                             Timing diagram

The timer resets when the time is up.                                                                          Set value

Note:  Output functions only during start signal input                                                         UP

       when setting is 0.                                                                                            0

                                                                                                               Set value

                                                                                                               DOWN

                                                                                                                     0

    Mode E: Interval (Timer resets when power comes        ON.)

    Basic operation                                        Detailed              operation

                                                                                     Power

       Power

                                                                                 Start signal

    Start signa*l

       input                  Timing                                                 Gate

       Output

*   Start signal   input  is enabled     during   timing.                            Reset

Timing starts when the start signal comes ON.                    Control output

The timer resets when the time is up.                            Timing diagram

While the start signal is ON, the timer starts when the                          Set value

power comes ON or when the reset input goes OFF.                                 UP

Note:  Output is disabled when the setting is 0.                                       0

                                                                                 Set value

                                                                                 DOWN

                                                                                       0

    Mode F: Cumulative (Timer does not reset when power comes ON.)

    Basic operation                                        Detailed operation

       Power                                                                         Power

    Start signal                                                                 Start signal

       input       Timing     Sustained

                                         Timing                                      Gate

       Output

Start signal enables timing (timing is stopped when the

start signal is OFF or when the power is OFF).                                       Reset

A sustained control output is used.

Note:  Output is instantaneous when setting is 0.                Control output

When the H5CX is used with power start in mode F                 Timing diagram

mode or F-1 (i.e., cumulative operation with output on                           Set value

hold), there will be a timer error (approximately 100 ms                         UP

                                                                                       0

each time the H5CX is turned ON) due to the                                      Set value

characteristics of the internal circuitry. Use the H5CX                          DOWN

with signal start if timer accuracy is required.                                       0

    Mode Z: ON/OFF-duty-adjustable flicker (Timer resets when power comes                                          ON.)

    Basic operation                                        Detailed operation

       Power                                                                         Power

    Start signa*l                                                                Start signal

       input              Timing               Timing

                     (cycle time)         (cycle time)                                 Gate

                   Timing                Timing

                   ON duty               ON duty

                     (%)                  (%)

       Output                                                                          Reset

* Start signal input is disabled during timing.

Timing starts when the start signal goes ON.                                     Control output

The status of the control output is reversed when time is                        Cycle time

up (ON at start).                                                Timing diagram  UP

While the start signal is ON, the timer starts when power                        ON duty setting

comes ON or when the reset input goes OFF.                                       (%) ON time

Note:  Normal output operation will not be possible if                                         0

       the set time is too short.                                                Cycle time

       Set the value to at least 100 ms (contact output                          ON duty setting

       type).                                                                    (%) ON time

                                                                                 DOWN

                                                                                               0

22
                                                                                                                                                                             H5CX-A@-N/-L@-N

                                                                                                                                                                                                                               Timer

Mode S: Stopwatch         (Timer resets  when   power     comes ON.)

Basic operation                                           Detailed                    operation

       Power                                                                              Power

                                                                                      Start signal

Start signal

       input               Timing

Gate/Reset                                                                            Gate/Reset

                                                                                          9999

                                                                                      Set time

                                                                      Timing diagram  UP

       Display                *                                                                   0

(for elapsed               *     RST  flashes

       time)                                                                          Set time

The signal starts and stops timing.                                                   DOWN

The display is held and timing is continued if the reset

or gate input is received during timing operation.                                                0

The timer resets if the reset or gate input is received

when the timing operation is stopped.                                                     Output

Note:  Output is instantaneous when setting is 0.

Models with Instantaneous Contact Outputs                                                                                                              Either       one-shot output or sustained output can                    be  selected.

Mode A-2: Power ON delay (Timer resets when power comes ON.)

Basic operation                                           Detailed operation

                                                                                                      t-a             t                           Rt                t           t-a       Rt                         t-a

       Power

                          Timing                                                          Power

Time-limit                                                                            Reset Key

       output

Instantaneous                                                                         Time-limit

       output                                                         contacts, NC

The Timer starts when the power comes ON or when                                      Time-limit

the reset input goes OFF.                                             contacts, NO

Note:  Output is instantaneous when setting is 0.         Instantaneous

                                                                      contacts, NC

                                                          Instantaneous

                                                                      contacts, NO

                                                                                                      t=   Set time,  Rt =   Reset time  (0.5  s  min.), t – a < t  (Indicates the time is less than the set time.)

Mode b: Repeat cycle 1 (Timer resets when power comes ON.)

Basic operation                                           Detailed operation

                                                                                                           t-a           t   t           t        t-a  Rt              t  t  t  t-a  t-a      Rt                          t-a

       Power

                t (time)  t (time)    t (time)  t (time)                                    Power

Time-limit                                                                                Reset Key

       output

Instantaneous                                                                             Time-limit

       output                                                                         contacts, NC

                                                          Sustained Output

The Timer starts when the power comes ON or when                                          Time-limit

the reset input goes OFF.                                                             contacts, NO

Note:  Normal output operation will not be possible if                                    Time-limit

       the set time is too short.                                                     contacts, NC

       Set the value to at least 100 ms.                  One-shot Output

                                                                                          Time-limit

                                                                                      contacts, NO

                                                                                      Instantaneous

                                                                                      contacts, NC

                                                                                      Instantaneous

                                                                                      contacts, NO

                                                                                                           t = Set    time,  Rt = Reset  time (0.5 s min.), t –     a < t (Indicates the time is less than the set time.)

Note:  H5CX-L8E@-N Precautions

       Set the Timer’s set value before using the Timer in a self-holding circuit.

                                                                                                                                                                                                                                              23
H5CX-A@-N/-L@-N

Timer

    Mode E: Interval (Timer resets when power comes ON.)

    Basic operation                                          Detailed operation

                                                                                           t-a               t                               Rt                  t                             t-a          Rt              t-a

           Power

                              Timing                                Power

       Time-limit                                                   Reset Key

           output

    Instantaneous                                                   Time-limit

           output                                                   contacts, NC

    The Timer starts when the power comes ON or when                Time-limit

    the reset input goes OFF.                                       contacts, NO

    Note:  Output is not instantaneous when setting is 0.           Instantaneous

                                                                    contacts, NC

                                                                    Instantaneous

                                                                    contacts, NO

                                                                                           t = Set time,     Rt   =  Reset  time (0.5     s  min.),  t  –  a
    Mode Z: ON/OFF-duty adjustable flicker (Timer resets when power comes ON.)

    Basic operation                                          Detailed operation

                                                                                           t-a               t                 t-a           Rt                  t                   t-a       t-a          Rt              t-a

       Power                                                                                          dty                   dty                            dty                    dty

                   Timing (cycle time)  Timing (cycle time)         Power

    Time-limit                                                      Reset Key

       output      Timing               Timing

                   (ON duty)            (ON duty)

Instantaneous                                                       Time-limit

       output                                                       contacts, NC

    The Timer starts when the power comes ON or when                Time-limit

    the reset input goes OFF.                                       contacts, NO

    Note:  Normal output operation will not be possible if          Instantaneous

           the set time is too short.                               contacts, NC

           Set the value to at least 100 ms.

                                                                    Instantaneous

                                                                    contacts, NO

                                                                                           t  =  Set  time,  dty  =  ON  duty  time,  Rt  =  Reset   time  (0.5  s  min.),  t  –  a  <  t  (Indicates  the  time  is  less  than  the  set  time.)

Note:      H5CX-L8E@-N Precautions

           Set the Timer’s set value before using the Timer  in  a  self-holding circuit.

24
                                                                                                                                      H5CX-A@-N/-L@-N

                                                                                                                                                   Twin Timer

Setting Procedure Guide

Operating Procedures for Twin Timer Function

Step1       Switching to a Twin Timer

            Power ON                                                 Press the           or        Key   to

                                                   Timer/twin timer  switch to a Twin Timer.

                                      +  1         selection mode

                           Hold down for 1 s min.                    tim        twn

            Run mode

                                                                     Timer    Twin timer

                                      +  1

                           Hold down for 1 s min.

Step2       Settings for basic functions can be performed with just the DIP switch.

            Note: There is no DIP switch on the H5CX-L8@. Go to                                       Step3     .

                      Key-protect Switch

                                                                                   Be sure to set pin 1 to ON when        using  the  DIP switch.

                                                                     ON

                                                                     OFF        1  2  3   4  5  6  7  8

            Item                                   OFF               ON                                  Pin 2     Pin 3              OFF time range

1           DIP switch settings             Disabled                 Enabled                             OFF       OFF                0.01 s to 99.99 s

2                                                                                                        ON        OFF                0.1 s to 999.9 s

            OFF time range               Refer to the table on the right.                                OFF       ON                 1 s to 9999 s

3

4                                                                                                        ON        ON                 0 min 01 s to 99 min 59 s

            ON time range                Refer to the table on the right.

5

6           Output mode                  Flicker OFF start  Flicker ON start                             Pin 4     Pin 5              ON time range

7           Timer mode                             UP                DOWN                                OFF       OFF                0.01 s to 99.99 s

8           Input signal width                     20 ms             1 ms                                ON        OFF                0.1 s to 999.9 s

Note:  All  the pins are factory-set  to OFF.                                                            OFF       ON                 1 s to 9999 s

                                                                                                         ON        ON                 0 min 01 s to 99 min 59 s

Be sure to turn ON pin 1 on the DIP switch.

Changes to DIP switch settings are enabled when the power                                is  turned     ON.

(Perform DIP switch settings while the power is OFF.)

After making DIP switch settings for basic operation, advanced functions can be added using the operation keys on the front panel.                               Refer to

Step3  on page 26 for details.

                                                                                                                                                                           25
H5CX-A@-N/-L@-N

Twin Timer

To switch to twin timer operation, use the procedure given below. For details, refer to page 31.

       Step3                       Settings that cannot be performed with the DIP switch are performed with the operation                                                            keys.

    •  Change to Function Setting Mode.

                                   Power ON                                          For details on operations in run mode, refer to page 28.

                                                   3 s min.      *1

                                   Run mode                 Function setting mode

                                                   3 s min.      *2

                              *1.  If the mode is switched to the function setting mode during operation, operation will continue.

                              *2.  Changes made to settings in function setting mode are enabled for the first time when the mode             is           changed  to   run  mode.

                                   Also, when settings are changed, the timer is reset (time initialized and output turned OFF).

                                                                     The characters displayed in reverse video are the default settings.

                                                                     When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).

                                                                     If pin 1 of the DIP switch is set to ON, the setting items indicated in               will not be displayed.

                                                   OFF time          Set the OFF time range using the                     keys.

                                                   range                                                                                                                             Time Range         List

                                                                                  s                s                  s   ……                       h                     s           Display            Set Value

                                                                     For details, refer to Time Range List.                                                                                             0.01 s to 99.99 s

                                                                                                                                                                                                        (default setting)

                                                   ON time           Set the ON time range using the                      keys.                                                                         0.1 s to 999.9 s

                                                   range

                                                                                  s                s                  s   ……                       h                     s                              1 s to 9999 s

                                                                     For details, refer to Time Range List.                                                                                             0 min 01 s to

                                                                                                                                                                                                        99 min 59 s

                                                                     Set the timer mode using the                        keys.                                                                          0.1 min to

                                                   Timer mode                                                                                                                                           999.9 min

                                                                     up              down                                                                                                               1 min to

                                                                     (UP)            (DOWN)                                                                                                             9999 min

                                                                                                                                                                                                        0 h 01 min to

                                                                     Set the twin timer output mode using the                          keys.                                                            99 h 59 min

       Function setting mode                       ON/OFF

                                                   start mode                                                                                                                                           0.1 h to 999.9  h

                                                                     toff            ton                     tof1         ton1

                                                                     ( ) ( ) ( ) ( ) Flicker
                                                                                     Flicker                 Flicker      Flicker                                                                       1 h to 9999 h

                                                                     OFF start 1     On Start 1       OFF start 2         On Start 2

                                                                     Note: Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CX-L8E@.                                            0.001 s to

                                                                     Set the input signal width using the                       keys.                                                                   9.999 s

                                                   Input signal

                                                   width

                                                                     20ms            1ms

                                                                     (20 ms)         (1 ms)

                                                                     Note: Not displayed for models with instantaneous contact outputs.

                                                   NPN/PNP           Set the NPN/PNP input mode using the                          keys.

                                                   input

                                                                     npn             pnp

                                                                     (NPN input)     (PNP input)

                                                                     Note: Displayed only for the H5CX-A@ and H5CX-A11@.

                                                                     Set the display color using the                     keys.

                                                   Display

                                                   color

                                                                     red             grn             org     r-g                g-r           r-o          o-r              g-o      o-g

                                                                     (Red)           (Green)       (Orange)  (Red-green)        (Green-red)  (Red-orange)  (Orange-red)  (Green-orange) (Orange-green)

                                                                     Note: Displayed only for models with terminal screws (H5CX-A@).

                                                   Instantaneous/    Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)

                                                   time-limit        using the                Keys.

                                                                     1c1c            2c

                                                                     (Instantaneous) (Time-limit)

                                                                     Note: Displayed only for models with instantaneous contact outputs.

       To next page                From next page

26
                                                                                                                                             H5CX-A@-N/-L@-N

                                                                                                                                                                Twin Timer

From previous                To previous

                       page  page

                                              Set value      Set  the digits  for the set  value limit using the corresponding       keys.

                                              upper limit 1

                                                                  1           9999

                                                                  (1)         (9999)

Function setting mode                         Set value      Set  the digits  for the set  value limit using the corresponding       keys.

                                              upper limit 2

                                                                  1           9999

                                                                  (1)         (9999)

                                                             Set  the key protect level    using the          keys.

                                              Key protect

                                              level

                                                                  kp-1        kp-2         kp-3               kp-4    kp-5           kp-6    kp-7

                                                                  (KP-1)      (KP-2)       (KP-3)             (KP-4)  (KP-5)         (KP-6)  (KP-7)

                                          *1

                                              Output ON                                    *1. Set the digits for the output ON alarm set value using the corresponding

                                              count alarm                                                     keys.

                                              set value/

                                              monitor value

                                                                                           • Models without Instantaneous Contact Outputs

                                                                                                                      Output ON                      ~

                                                                                                                      count alarm            0                  9999

                                                                                                                      set value      (0 x 1000 times) (9999 x 1000 times)

                                                                                                                      Output ON

                                                                                                                      count monitor  Note: The monitor value is only displayed.

                                                                                                                      value                  It cannot be set.

                                                                                           •          Models  with    Instantaneous Contact Outputs

                                                                                                                      Instantaneous

                                                                                                                      output 1               0       ~          9999

                                                                                                                      (OUT1) ON

                                                                                                                      count alarm    (0 x 1000 times) (9999 x 1000 times)

                                                                                                                      set value

                                                                                                                      Instantaneous

                                                                                                                      output 2                       ~

                                                                                                                      (OUT2) ON              0                  9999

                                                                                                                      count alarm    (0 x 1000 times) (9999 x 1000 times)

                                                                                                                      set value

                                                                                                                      Instantaneous

                                                                                                                      output 1

                                                                                                                      (OUT1) ON      Note: The monitor value is only displayed.

                                                                                                                      count monitor          It cannot be set.

                                                                                                                      value

                                                                                                                      Instantaneous

                                                                                                                      output 2       Note: The monitor value is only displayed.

                                                                                                                      (OUT2) ON              It cannot be set.

                                                                                                                      count monitor

                                                                                                                      value

                                                                                                                                                                                 27
H5CX-A@-N/-L@-N

Twin Timer

Explanation of Functions

Operating Procedures for Twin Timer Function

Items marked with stars () can be set using the DIP switch.

OFF Time Range (oftr)                                                                     NPN/PNP Input Mode (imod)

Set the time range for the OFF time in the range 0.000 s to 9,999 h.                       Select either NPN input (no-voltage input) or PNP input (voltage input)

Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),              as the input format. Set an NPN input when using a 2-wire sensor.

and -- min -- s (99 min 59 s) can be made with the DIP switch. Use the                     The same setting is used for all external inputs.

operation keys if another type of setting is required.                                     For details on input connections, refer to "Input Connections" on

ON Time Range (ontr)                                                                      page 9.

Set the time range for the ON time in the range 0.001 s to 9,999 h.                        Display Color (colr)

Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),              (Terminal black model: H5CX-A@ only)

and -- min -- s (99 min 59 s) can be made with the DIP switch. Use the                     Set the color used for the present value.

operation keys if another type of setting is required.                                                                 Output OFF                       Output ON

Timer Mode (timm)                                                                                  red                                Red (fixed)

Set either the elapsed time (UP) or remaining time (DOWN) mode.                                     grn                               Green (fixed)

In UP mode, the elapsed time is displayed, and in DOWN mode, the                                    org

remaining time is displayed.                                                                                                          Orange (fixed)

ON/OFF Start Mode (totm)                                                                           r-g                Red                              Green

Set the output mode.                                                                                g-r                Green                            Red

Set either flicker OFF start or flicker ON start. (For details on output                            r-o                Red                              Orange

mode operation, refer to "Timing Charts" on page 29.)                                               o-r                Orange                           Red

Input Signal Width (iflt)                                                                          g-o                Green                            Orange

Set the minimum signal input width (20 ms or 1 ms) for signal, reset,                               o-g                Orange                           Green

and gate inputs.

The same setting is used for all external inputs (signal, reset, and gate                  Key Protect Level (kypt)

inputs).                                                                                   Set the key protect level.

If contacts are used for the input signal, set the input signal width to                   Refer to “Key Protect Level” on page 32.

20 ms.

Processing to eliminate chattering is performed for this setting.

Operation in Run Mode

Operating Procedures for Twin Timer Function

                                       Present value     Set the digits for the OFF set time using the corresponding            keys.

                                       OFF set time

                                       Present value     Set the digits for the OFF set time using the corresponding            keys.

                                       ON set time

    Note: 1.  The display will automatically show the OFF set time when the OFF time is being       timed and the  ON set time  when the  ON time   is  being  timed.

    Note: 2.  H5CX-L8E@-N Precautions

              Set the Timer’s set value before using the Timer in a self-holding circuit.

Present Value and OFF Set Time                                                             Present Value and ON Set Time

The present value is displayed in the main display and the OFF set                         The present value is displayed in the main display and the ON set

time is displayed in the sub-display. Set the OFF time.                                    time is displayed in the sub-display. Set the ON time.

28
                                                                                                   H5CX-A@-N/-L@-N

                                                                                                   Twin Timer

Timing Charts

Operating Procedures for Timer Function

Models without Instantaneous Contact Outputs

The gate input is not included in the H5CX-L8@ models.

Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)

Basic operation                                                Detailed operation

                                                                                   Power

       Power

                                                                               Start signal

Start signa*l

       input       Timing   Timing  Timing       Timing                                Gate

                    OFF     ON              OFF  ON

Output                                                                             Reset

* Start signal input is disabled during timing.

                                                               Control output

Timing starts when the start signal goes ON.

The status of the control output is reversed when time is                      OFF time

up (OFF at start).                                             Timing diagram  UP

While the start signal is ON, the timer starts when the                            ON time

power comes ON or when the reset input goes OFF.                                       0

Note:  Normal output operation will not be possible if                         OFF time

       the set time is too short.                                              DOWN

       Set the value to at least 100 ms (contact output                            ON time

       type).

                                                                                       0

Mode ton: Flicker OFF start 1 (Timer resets when power comes ON.)

Basic operation                                                Detailed operation

                                                                                   Power

Power

                                                                               Start signal

Start signa*l

       input       Timing   Timing  Timing       Timing                                Gate

                    ON      OFF             ON   OFF

Output                                                                             Reset

* Start signal input is disabled during timing.

                                                               Control output

Timing starts when the start signal goes ON.

The status of the control output is reversed when time is                      OFF     time

up (ON at start).                                              Timing diagram  UP

While the start signal is ON, the timer starts when the                            ON  time

power comes ON or when the reset input goes OFF.                                       0

Note:  Normal output operation will not be possible if                         OFF     time

       the set time is too short.                                              DOWN

       Set the value to at least 100 ms (contact output                            ON  time

       type).

                                                                                       0

Mode toff-1: Flicker OFF start 2 (Timer does not reset when power comes                      ON.)

Basic operation                                                Detailed operation

                                                                                   Power

       Power

Start signa*l                                                                  Start signal

       input        Timing  Timing  Timing  a    b

                    OFF     ON      OFF                                                Gate

       Output

                                            (a + b = ON time)                      Reset

* Start signal input is disabled during timing.

                                                               Control output

Timing starts when the start signal goes ON.

The status of the control output is reversed when time is                      OFF time

up (OFF at start).                                             Timing diagram  UP

While the start signal is ON, the timer starts when the                            ON time

power comes ON or when the reset input goes OFF.                                       0

Note:  Normal output operation will not be possible if                         OFF time

       the set time is too short.                                              DOWN

       Set the value to at least 100 ms (contact output                            ON time

       type).

                                                                                       0

                                                                                                                    29
H5CX-A@-N/-L@-N

Twin Timer

    Mode ton-1: Flicker ON start 2 (Timer does not reset                   when power comes                             ON.)

    Basic operation                                                            Detailed operation

                                                                                                      Power

           Power

       Start signa*l                                                                              Start signal

           input       Timing    Timing     Timing     a          b

                             ON  OFF        ON                                                            Gate

           Output

                                                       (a + b = OFF time)                             Reset

    *  Start signal   input  is  disabled   during     timing.

                                                                                  Control output

    Timing starts when the start signal goes ON.

    The status of the control output is reversed when time is                                     OFF     time

    up (ON at start).                                                             Timing diagram  UP

    While the start signal is ON, the timer starts when the                                           ON  time

    power comes ON or when the reset input goes OFF.                                                          0

    Note:  Normal output operation will not be possible if                                        OFF     time

           the set time is too short.                                                             DOWN

           Set the value to at least 100 ms (contact output                                           ON  time

           type).

                                                                                                              0

Models with Instantaneous Contact Outputs

    Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)

    Basic operation                                                        Detailed operation

                                                                                                                 t-a          t-off  t-on   t-off  t-b  Rt          t-off  t-on   t-off         t-b      t-a        Rt        t-a

           Power                                                                                  Power

                      Toff time  Ton time   Toff time  Ton time

       Time-limit                                                                 Reset Key

           output

                                                                                                  Time-limit

Instantaneous                                                                     contacts, NC

           output

    The Timer starts when the power comes ON or when                                              Time-limit

    the reset input goes OFF.                                                     contacts, NO

    Note:  Normal output operation will not be possible if                        Instantaneous

           the set time is too short.                                             contacts, NC

           Set the ON time and OFF time to at least 100                           Instantaneous

           ms.                                                                    contacts, NO

                                                                                                                 t-on = ON time, t-off = OFF time, Rt = Reset       time   (0.1 s min.), t – a  < t-off  and  t  –  b<  t-on

                                                                                                                 (Indicates the time is less than the set time.)

    Mode ton: Flicker ON start 1 (Timer resets when power comes ON.)

    Basic operation                                                        Detailed operation

                                                                                                                 t-b          t-on   t-off  t-on   t-a  Rt          t-on   t-off  t-on          t-a      t-b        Rt        t-b

           Power                                                                                  Power

                      Ton time   Toff time  Ton time   Toff time

       Time-limit                                                                 Reset Key

           output

                                                                                                  Time-limit

Instantaneous                                                                     contacts, NC

           output

    The Timer starts when the power comes ON or when                                              Time-limit

    the reset input goes OFF.                                                     contacts, NO

    Note:  Normal output operation will not be possible if                        Instantaneous

           the set time is too short.                                             contacts, NC

           Set the ON time and OFF time to at least 100                           Instantaneous

           ms.                                                                    contacts, NO

                                                                                                                 t-on = ON    time, t-off = OFF time, Rt = Reset    time   (0.1 s min.), t – a  < t-off  and  t  –  b<  t-on

                                                                                                                 (Indicates   the time is less than the set time.)

Note:      H5CX-L8E@-N Precautions

           Set the Timer’s set value before using the Timer                in  a  self-holding                circuit.

30
                                                                                                                                      H5CX-A@-N/-L@-N

Timer/Twin Timer Selection Mode (Function Selection)

Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode.

The H5CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be

confirmed using the front display.

                                     Power ON

                                                                                                               Key                                                          1   Key

Run mode                                                                    Caution

                                     +                                      To change the mode to timer/twin timer selection mode,

                                 *2  1         *1                           hold down the          1     key for 1 s min. with the    key held

                                     1 s min.                               down. The           1  key must be pressed before the key. If the

                                                                            key is pressed first, the mode will not change.

Timer/Twin Timer Selection Mode                    Timer/Twin               Select either tim timer operation or twn twin timer operation       using  the

                                                                                         keys.

                                                   timer selection          Note: The H5CX is factory-set for timer operation.

                                                                            Confirm   the status of DIP switch pins 1 to 8 using the            keys.

                                                   DIP switch               Note: 1.  This display is not supported with H5CX-L8@-N.

                                                   monitor                      2.    This display is only possible when DIP switch pin 1 (DIP switch settings

                                                   Convenient                         enable/disable) is set to ON (enable).

                                                                                      Example

                                                                            ON

                                                                            OFF       1  2  3   4  5  6  7  8

                                                                                                                                      Indicates  that  DIP  switch  pin  8  is  ON.

                                                                                                                                      Indicates  that  DIP  switch  pin  7  is  OFF.

                                                                                                                                      Indicates  that  DIP  switch  pin  6  is  ON.

                                                                                                                                      Indicates  that  DIP  switch  pin  5  is  OFF.

                                                                                                                                      Indicates  that  DIP  switch  pin  4  is  ON.

                                                                                                                                      Indicates  that  DIP  switch  pin  3  is  OFF.

                                                                                                                                      Indicates  that  DIP  switch  pin  2  is  ON.

                                                                                                                                      Indicates  that  DIP  switch  pin  1  is  ON.

*1.  When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF.

     Timing operation is not performed in timer/twin timer selection mode.

*2.  Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode.

     If settings are changed, the HC5X is automatically reset (present value initialized, output turned OFF).

                                                                                                                                                                                      31
H5CX-A@-N/-L@-N

Key Protect Level

When the key-protect switch is set to ON, it is possible to prevent setting                errors  by  prohibiting    the  use   of  certain  operation  keys  by  specifying      the

key protect level (KP-1 to KP-7).

The key protect indicator is lit while the key-protect switch is set to ON.

                                                         OFF *                  ON

                                                      (Disabled)                (Enabled)

                                   * Factory-set to OFF

                                                                  Key protect indicator

                                                                                                                      Details

     Level                         Meaning                         Changing mode*                  Switching display                 Reset Key                 Up/down key

                                                                                                   during operation

     KP-1                                                                       Invalid                      Valid                   Valid                         Valid

    (default setting)

     KP-2                                                                       Invalid                      Valid                   Invalid                       Valid

     KP-3                                                                       Invalid                      Valid                   Valid                         Invalid

     KP-4                                                                       Invalid                      Valid                   Invalid                       Invalid

     KP-5                                                                       Invalid                      Invalid                 Invalid                       Invalid

     KP-6                                                                       Invalid                      Invalid                 Valid                         Valid

     KP-7                                                                       Invalid                      Invalid                 Invalid                       Valid

*   Changing mode to Timer/Twin Timer Selection Mode or Function Setting Mode.

Self-diagnostic Function

The following displays will appear if an error occurs.

     Main display      Sub-display                                Error                           Output status            Correction method             Set value after reset

     e1                Not lit              CPU                                                    OFF                Either press the reset key or            No change

                                                                                                                      reset the power supply.

     e2                Not lit              Memory error (RAM)                                     OFF                Reset the power supply.                  No change

     e2                sum                  Memory error EEPROM *1                                 OFF                Reset Key                          Factory setting

     e3 *2             No change            Output ON count alarm set                             No change           Reset Key                                No change

                                            value exceeded

*1.  This includes times when the life of the EEPROM has expired.

*2.  The normal display and e3 will appear alternately.

     When the Reset Key is pressed, e3 will no longer be displayed even if the             alarm  set value is exceeded. (Monitoring is possible, however, because the Timer will

     continue without clearing the output ON count.)

32
                                                                                                                                           H5CX-B@-N

                  Digital Timer H5CX-B@-N

• H5CX Digital Timers with 6-digit Display, 2-stage Setting,

     and Forecast Output (DIN 48 x 48-mm)

• Times the daily operating hours of machinery and tools,

     predicting and notifying when maintenance is required.

• Easy-to-read backlit negative LCD with 6 digits (displays

     to 99999.9 h).

• The 2-stage settings and forecast output are ideal for

     maintenance applications.

Specifications

Ratings

Classification                            Digital Timer with 6-digit display, 2-stage setting, and forecast output

             Power supply voltage         12 to 24 VDC

Ratings      Operating voltage            90% to 110% rated supply voltage

             fluctuation range

             Power consumption            Approx. 2.3 W *1

Mounting method                           Flush mounting

External connections                      Screw terminals

Degree of protection                      IEC IP66, UL508 Type 4X (indoors) for panel front surface only and only when Y92S-29 Waterproof Packing is   used

Digits                                    6 digits

Time range                                0.01 s to 9999.99 s, 1 s to 99 h 59 min 59 s, 0.1 min to 99999.9 min, 0.1 h to 99999.9 h

Timer mode                                Elapsed time (Up)

             Input signals                Signal, reset, gate

                                          No-voltage Input     ON impedance          : 1 kΩ max. (Leakage current: 12 mA when 0 Ω)

                                                               ON residual voltage : 3 V max.

Inputs       Input method                                      OFF impedance         : 100 kΩ min.

                                          Voltage Input        High (logic) level    : 4.5 to 30 VDC

                                                               Low (logic) level     : 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)

                                          No-voltage (NPN) input/voltage (PNP) input (switchable)

             Signal, reset, gate          Minimum input signal width: 1 or 20 ms (selectable, same for all input)

Reset system                              Power resets (only for A mode), external and manual reset

Power reset                               Minimum power-opening time: 0.5 s (except for F-1 mode)

Reset voltage                             10% max. of rated supply voltage

Sensor waiting time                       250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)

             Output modes                 A, F-1

Outputs      Output type                  Transistor output:   NPN open collector, 100 mA at 30 VDC max. residual voltage: 1.5 VDC max. (Approx. 1 V)

                                          Leakage current: 0.1 mA max.

                                          7-segment, negative transmissive LCD;

Display                                   Present value: 10-mm-high characters, red

                                          Set value: 6-mm-high characters, green *2

Memory backup                             EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.

Operating temperature range               -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)

Storage temperature range                 -25 to 70°C (with no icing or condensation)

Operating humidity range                  25 to 85%

Case color                                Black (N1.5)

Attachments                               Waterproof packing, flush mounting adapter, unit label

*1.  Inrush current will flow for a short time when the power supply is turned ON.

     Inrush Current (Reference Values)

         Voltage            Applied voltage         Inrush current (peak value)        Time

        12 to 24 VDC            26.4 VDC                       4.4 A                   1.7 ms

*2.  The display is lit only when the power is ON.

                                                                                                                                                             33
H5CX-B@-N

Characteristics

                                    Power-ON start: ±0.01% ±50 ms max. (See note 1.)

    Accuracy of operating time      Signal start: ±0.005%±0.03 ms max. (See note 1.)

    and setting error               Signal start for transistor output model: ±0.005%±3 ms max. (See note 1 and 2.)

    (including temperature and      If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the       sensor  waiting

    voltage influences)             time passes.

                                    Note:  1.  The values are based on the set value.

                                           2.  The value is applied for a minimum pulse width of 1 ms.

    Insulation resistance           100 MΩmin. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts

    Dielectric strength             2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts

                                    1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit

    Impulse withstand voltage       1.0 kV (between power terminals)

                                    1.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)

    Noise immunity                  ±480 V (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator

                                    (pulse width: 100 ns/1 µs, 1-ns rise)

    Static immunity                 Destruction: 15 kV

                                    Malfunction: 8 kV

    Vibration          Destruction  10 to 55 Hz with 0.75-mm single amplitude in three directions for 2 h each

    resistance         Malfunction  10 to 55 Hz with 0.35-mm single amplitude in three directions for 10 min each

    Shock              Destruction  300 m/s2 in three directions, three cycles

    resistance         Malfunction  100m/s2 in three directions, three cycles

    Weight                          Approx. 105 g (Timer only)

Applicable Standards

    Approved safety standards       UL508/Listing, CSA C22.2 No. 14, conforms to EN 61812-1 (pollution degree 2/overvoltage category III)

                                    Conforms to VDE0106/P100 (finger protection).

                                    (EMI)                                    EN61812-1

                                    Emission Enclosure:                      EN55011 Group 1 class A

                                    (EMS)                                    EN61812-1

                                    Immunity ESD:                            EN61000-4-2:  6 kV contact discharge (level 2)

                                                                                           8 kV air discharge (level 3)

    EMC                             Immunity RF-interference:                EN61000-4-3:  10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level              3);

                                                                                           10 V/m (Pulse-modulated, 900 MHz         5 MHz) (level 3)

                                    Immunity Conducted Disturbance:          EN61000-4-6:  10 V (0.15 to 80 MHz) (level 3)

                                    Immunity Burst:                          EN61000-4-4:  2 kV power-line (level 3);

                                                                                           1 kV I/O signal-line (level 4)

                                    Immunity Surge:                          EN61000-4-5:  1 kV line to lines (power and output lines) (level 3);

                                                                                           2 kV line to ground (power and output lines) (level 3)

I/O Functions

                Start signal                                 Starts timing.

                                                             • Resets present value. (The present value returns to 0.)

    Inputs      Reset                                        • Timing stops and control output turns OFF while reset input is  ON.

                                                             • Reset indicator is lit while reset input is ON.

                Gate                                         Inhibits timer operation.

                Forecast value      Control output (OUT2)    Turns ON when the present value reaches the set value.

                setting             Forecast output (OUT1)   Turns ON when the present value reaches the forecast value.

    Outputs                         Control output 2 (OUT2)  Turns ON when the present value reaches set value 2.

                Absolute value

                setting             Control output 1 (OUT1)  Turns ON when the present value reaches set value 1.

Response Delay Time When Resetting (Transistor Output)

The following table shows the delay from when the reset signal is input until the output is turned OFF.

                                                             (Reference value)

    Minimum reset signal width                 Output delay time

                     1 ms                            0.8 to 1.2 ms

                20 ms                                15 to 25 ms

34
                                                                                                                                                                                                                                                                                                                                                                 H5CX-B@-N

Connections

Block Diagram                                                                                                                                                                                                                               Input Circuits

                                                                                                                                                                                                                                            Signal, Reset, and Gate Input

                                           Output circuit                                                                                 Power supply

                                                                                                                                                  circuit                                                                                   No-voltage Inputs (NPN Inputs)                                                 Voltage Inputs (PNP Inputs)

                                           (Basic insulation)

                                                                                                                                                  Display circuit                                                                                                                        +14 V

                      Input circuits                                                                   Internal control                                                                                                                                                        1 kΩ

                                                                                                                      circuit                     Key switch                                                                                                                                                                               Approx. 4.7 kΩ

                                                                                                                                                  circuit                                                                                   IN                                                      Internal               IN                                                          Internal

                                                                                                                                                                                                                                                                                                    circuit                                                                            circuit

Terminal Arrangement                                                                                                                                                                                                                        Transistor Output

                                                                                                                                                                                                                                            •          The transistor output of                                         NPN Output                                          PNP Output

       Reset  Signal  Gate                 Reset                                                                                                                                                                                                       the H5CX is insulated

                                                                                                                                                                                                                                                       from the internal circuitry

0V                                                                                                                                                                                                                                                     by a photocoupler, so the

                                                                                                                                                                                                                                                       transistor output can be

6      7      8       9                    10                                                                                                                                                                                                          used as both NPN and                                                                           Load                      Load

                                                                                              Note:                      1.    The power supply and input circuit                                                                                      PNP output.                                                                            +                                                   +

                                                                                                                               are not isolated.                                                                                                                                                                        Power              for load                                    Power      for  load

                                                                                                                         2.    Terminals 1 and 6 are connected

              12                           13            OUT 1                                                                 internally.                                                                                                  •          The diode connected to                                                                 Timer

                                                                                                                         3.    Terminals 7 and 10 have the same                                                                                        the collector of the output

                                                                                                                               reset function. The same function will

                                                                                                                               be performed whichever terminal is                                                                                      transistor is used to

1      2      3       4                    5                                                                                   connected. Terminals 7 and 10 are                                                                                       absorb inverted voltage

                      OUT   2                                                                                                  not connected internally, however, so                                                                                                                                                                                                            Inductive

(–)    (+)                                                                                                                     do not use them for cross-over wiring.                                                                                  that is generated when an                                                                                                load

                                                                                                                                                                                                                                                       inductive load is                                                                                         +

                                                                                                                                                                                                                                                       connected to the H5CX.                                                                         Power      for  load

Input Connections

The inputs of the H5CX-B are no-voltage (short-circuit or open) inputs                                                                                                                                            or voltage inputs.

No-voltage Inputs (NPN Inputs)

Open Collector                                                                                                                 Voltage Output                                                                                     Contact Input                                                                         DC Two-wire Sensor

     PLC or                                                                                                                               Sensor

     sensor

                           0 V for inputs         Reset                     Signal            Gate             Reset                                          inputs     Reset     Signal     Gate      Reset                                                   inputs         Reset     Signal     Gate      Reset                           inputs     Reset      Signal      Gate       Reset

                                                                                                                                                              fo r                                                                                              fo r                                                                          fo r

                                                                                                                                                              V                                                                                                 V                                                                             V

                                                                                                                                                              0                                                                                                 0                                                                             0

                      6                    7                8                          9               10                                                  6          7         8          9        10                                                    6             7             8          9        10                               6          7          8          9          10

                      Note: Operate with transistor ON                                                                                            Note: Operate with transistor                                   ON                                   Note: Operate                     with relay ON                                     Note: Operate with transistor                          ON

No-voltage Input Signal Levels                                                                                                                                                                                                                                                                                          Applicable Two-wire Sensor

                            Short-circuit level (Transistor ON)                                                                                                                                                                                                                                                      •  Leakage current:              1.5 mA max.

                            • Residual voltage: 3 V max.                                                                                                                                                                                                                                                             •  Switching capacity: 5 mA min.

No-contact                  • Impedance when ON: 1 kΩ max.                                                                                                                                                                                                                                                           •  Residual voltage:             3.0 VDC max.

input                                      (The leakage current is approx. 12 mA when the impedance is 0 Ω.)                                                                                                                                                                                                         •  Operating voltage:            10 VDC

                            Open level (Transistor OFF)

                            • Impedance when OFF: 100 kΩ min.

Contact input               Use contacts which can adequately switch 5 mA at 10 V

Voltage Inputs (PNP Inputs)

No-contact Input (NPN Transistor)                                                                                                                 No-contact Input                                                (PNP                      Transistor)                                                   Contact Input

              Sensor                                                                                                                                                            Sensor

                                                            0 V for inputs             Reset           Signal            Gate      Reset                                                                          0 V for inputs     Reset     Signal     Gate          Reset                                              0 V for inputs     Reset      Signal     Gate        Reset

                                                         6                          7               8                 9        10                                                                              6                  7         8          9        10                                                      6                  7          8          9          10

                                                  Note: Operate with transistor OFF                                                                                                                     Note: Operate with transistor ON                                                                                Note: Operate with relay ON

Voltage Input Signal Levels

High level (Input ON): 4.5 to 30 VDC

Low level (Input OFF): 0 to 2 VDC

Note:     1.  The DC voltage must be 30 VDC max.

          2.  Input resistance: Approx. 4.7 kΩ

                                                                                                                                                                                                                                                                                                                                                                                                             35
H5CX-B@-N

Nomenclature

                 Display Section                                                                                                                Operation Key

1.  Key Protection Indicator (orange)                                                                                      8.  Mode Key

    Lit when the reset input or Reset Key is ON.                                                                               (Changes modes and setting items)

2.  Control Output Indicator (orange)                                                                                4

    Forecast value setting                                  1                                                        5     9. Reset Key

    Forecast output ON: OUT 1 is lit.                       2                                                        6         Resets present value and output.

    Control output ON: OUT 2 is lit.                        3                                                        7     10. Up Keys 1 to 6

    Absolute value setting                                  8

    Control output 1 ON: OUT 1 is lit.

    Control output 2 ON: OUT 2 is lit.                      9                                                        10                               Switches

3.  Reset Indicator (orange)                                                                                               11. Key-protect Switch

    Lit when the reset input or Reset Key is ON.                                Sixth digit        First digit                                        OFF                        ON

                                                                                                                               (Default  setting)  (Disabled)              (Enabled)

4.  Present Value Display (red)

    Character height: 10 mm

    If the time range is 0.0 min or 0.0 h, the decimal      11                                                       12

    point flashes to indicate timing operation.

5.  Time Unit Indicators (green)

6.  Set Value (green)                                                                                                      12. DIP Switch

    Character height: 6 mm

                                                                                                                               ON

7.  Set Value 1, 2 Indicator (green)

    Character Size  Character Size                                                                                             OFF       1   2     3  4   5  6     7   8

    for Present     for Set Value

    Value Display   Display

        10mm                 6mm

Key Protect Level

When the Key-protect Switch is ON, key operations are prohibited                                   The Key Protection Indicator is lit orange when the Key-protect Switch

according to the settings for DIP switch pins 6 to 8, thus preventing                              is ON.

setting errors.                                                                                    If the key protect switch is ON, you will not be able to switch to

The Key-protect Switch can be turned ON and OFF while the power                                    Function Setting Mode.

is ON.

Dimensions                                                                                                                                                                       (unit: mm)

Digital Timers

Digital Timers                                                                                                                 Panel Cutouts

H5CX-BWSD-N (Flush Mounting Models)                                                                                            Panel cutouts areas           shown         below.    (according

                                                                                                                               to DIN43700)

                                                                                                                                                                       60  min.

                                                  48×48                         6            59                                                              45+–00.6

                                                                                                                                                45+–00.6

                                                                                                           44.8×44.8

                                                                                                                                                15 min.

                                                                                                                                         60 min.

                                                 Note: M3.5 terminal screw (effective length: 6 mm)

                                                                                                                               Note:     1.  The mounting panel thickness should

                                                                                                                                             be 1 to 5 mm.

                                                                                                                                         2.  To allow easier operation, it is

                                                                                                                                             recommended that Adapters be

                                                                                                                                             mounted so that the gap between

Dimensions with Flush Mounting Adapter                                                                                                       sides with hooks is at least 15 mm

                                                                                                                                             (i.e., with the panel cutouts separated

H5CX-BWSD-N (Provided with Adapter and Waterproof                                  Packing)                                                  by at least 60 mm).

                                                                                                                                         3.  It is possible to mount Timers side by

                                                                                                                                             side, but only in the direction without

                                                            Y92S-29 (provided)     Panel     Y92F-30 (provided)                              the hooks. However, if Timers are

                                                            Waterproof Packing               Flush Mounting Adapter                          mounted side by side, water

                                                                                                                                             resistance will be lost.

                                                                                                                                                n side by side mounting

                                       58                       (51)

                                                                                                                                                                A

                                                                                                                                                      A= (48n–2.5)+–10

                                                                                                                                             With Y92A-48F1 attached.

                                                        48      7.5                          57.5                                            A={48n–2.5+(n–1)×4}–+01

                                                                                                                                             With Y92A-48 attached.

                                                                                                                                             A= (51n–5.5)–+01

Accessories (Order Separately)

Refer to page 12 for details.

36
                                                                                                                                              H5CX-B@-N

Operating Procedures

DIP Switch Settings

All functions are set using the DIP switch.

           Item            OFF                   ON                         Pin 1  Pin 2  Time range

1                          Refer to the table on the                        OFF    OFF    0.1 h to 99999.9 h

2  Time range                         right.                                ON     OFF    0.01 s to 9999.99 s

3  Output modes            F-1 mode              A mode                     OFF    ON     0 h 00 min 01 s to

4  Input signal width      20 ms                 1 ms                                     99 h 59 min 59 s

                           NPN                   PNP                        ON     ON     0.1 min to 99999.9 min

5  NPN/PNP input mode      (no-voltage)          (voltage)

6  Reset Key protection    Disabled              Enabled

7  Up Key protection       Disabled              Enabled

8  Mode Key protection     Disabled              Enabled                                                          ON

Note:  1.  All the pins are factory-set to OFF.

       2.  DIP switch settings are effective when the power is                                                    OFF   1      2  3  4  5  6  7  8

           turned ON again. (Set the DIP switch before installation

           and power-up.)

Operation in Run Mode

Set the digits for the set values using the corresponding                   Key.

Forecast       Value     Setting                                                          Absolute  Value      Setting

                           Present value                                                                          Present value

                           Set value      Each time the         Key is pressed,                                   Set value 1     Each time the     Key is pressed,

                                          the sub-display will switch between                                                     the sub-display will switch between

                                          the set value (“SET” is lit) and the                                                    set value 1 (“SET 1” is lit) and set

                                          forecast set value (“1” is lit).                                                        value 2 (“SET 2” is lit).

                           Present value                                                                          Present value

                           Forecast set value                                                                     Set value 2

                                                                                                                                                                        37
H5CX-B@-N

Operation in Function Setting Mode

    Settings that cannot be performed with the DIP switch are performed with the operation keys.

    • Change to Function Setting Mode.

                                Power ON

                                          3 s min.     *1

                                Run mode           Function setting mode

                                          3 s min.     *2

                           *1.  If the mode is switched to the function setting mode during operation, operation will continue.

                           *2.  Changes made to settings in function setting mode are enabled for the first time when the mode             is changed to run  mode.

                                Also, when settings are changed, the timer is reset (time initialized and output turned OFF).

                                          Absolute         Set the digits for the set values using the

                                          value setting/   corresponding  Key.

                                          forecast value

                                          setting                     ~

                                                           (Forecast      (Absolute

                                                           value setting) value setting)

                                                           Set the digits for the set values using the

                                          Set value        corresponding  Key.

                                          upper limit

                                                                      ~

                                                           (1)            (999999)

                                                           Set the digits for the set values using the

                                                           corresponding  Key.

                                          Forecast

                                          setting upper               ~

                                          limit            (1)            (999999)

                                                           Note: Displayed only in forecast setting mode.

    Function Setting Mode                                  Set the digits for the set values  using  the

                                          Output 1         corresponding  Key.

                                          (OUT1)

                                          ON count                    ~

                                          alarm set value  (0 x 1000      (9999 x 1000

                                                           times)         times)

                                                           Set the digits for the set values  using  the

                                          Output 2         corresponding  Key.

                                          (OUT2)

                                          ON count                    ~

                                          alarm set value  (0 x 1000      (9999 x 1000

                                                           times)         times)

                                          Output 1

                                          (OUT1)           Note: The monitor value is only displayed. It cannot                  be  set.

                                          ON count

                                          monitor value

                                          Output 2

                                          (OUT2)           Note: The monitor value is only displayed. It cannot be set.

                                          ON count

                                          monitor value

38
                                                                                                                                                 H5CX-B@-N

Explanation of Functions

Absolute value setting/forecast value setting                                             Absolute Value Setting

(setm)                                                                                                         Example: F-1 Mode        Present

Set value 1 can be set as the forecast value setting (ofst) or the                                                                      value

absolute value setting (abs).                                                                Set value 2

Forecast Value Setting                                                                       Set value 1

                          Example: F-1 Mode  Present                                                     0

                                             value

                Set                                                                          Control output 1

     Forecast   value                                                                             (OUT1)

     set value                                                                               Control output 2

                Forecast                                                                          (OUT2)

                value

                     0                                                                    •  OUT1 (control output 1) turns ON when the present value reaches

                                                                                             set value 1.

     Forecast output                                                                      •  OUT2 (control output 2) turns ON when the present value reaches

                (OUT1)                                                                       set value 2.

     Control output                                                                       Refer to pages 18 and 28 for information on other functions.

                (OUT 2)

•    OUT1 (forecast output) turns ON when the present value reaches

     the forecast value.

     Forecast value = Set value - Forecast set value

     Note: The forecast set value is used to set the deviation for the set value.

•    OUT2 (control output) turns ON when the present value reaches

     the set value.

•    If the forecast set value ≥ set value, OUT1 (forecast output) will turn

     ON as soon as timing starts.

Self-diagnostic Function

The following displays will appear if an error occurs.

     Main display         Sub-display                    Error                            Output status        Correction method                 Set value after reset

        e1                     Not lit       CPU                                             OFF               Either press the Reset Key or     No change

                                                                                                               reset the power supply.

        e2                     Not lit       Memory error (RAM)                              OFF               Reset the power supply.           No change

        e2                     sum           Memory error EEPROM *1                          OFF               Reset Key.                        Factory setting

        e3 *2             No change          Output ON count alarm set                    No change            Reset Key                         No change

                                             value exceeded

*1.  This includes times when the life of the EEPROM has expired.

*2.  The normal display and e3 will appear alternately.

     When the Reset Key is pressed, e3 will no longer be displayed even if the     alarm  set value is exceeded. (Monitoring is possible, however, because the Timer will

     continue without clearing the output ON count.)

                                                                                                                                                                           39
H5CX-B@-N

Timing Charts

    Mode A: Signal ON delay (Timer resets when power comes ON.)

    Basic operation                                                         Detailed operation

                Power                                                                                               Power

       Start signal inpu*t                                                                                  Start signal

                                    Timing

                Control
    ( ) Forecast
    output      output 1                                                                                            Gate

    OUT1        OUT1

    ( ) Control
                Control                                                                                             Reset

    output      output 2

    OUT2        OUT2                                                                        Timing diagram

    (  ) The names in parentheses are used for the absolute value setting.                                          999999

    * Start signal input is disabled during timing.                                                         Set value (SV 2)

                                                                                                            Forecast value

                                                                                                                    (SV 1)

    • Timing starts when the start signal goes ON.                                                                      0

    • While the start signal is ON, the timer starts when the                                                       OUT1

    power comes ON or when the reset input goes OFF.

    • A sustained control output is used.

    • Timing stops when the time is up.                                                                             OUT2

    Note:   Output is instantaneous when the set value is 0.                                The names in parentheses                 are  used  for  the  absolute  value  setting.

    Mode F-1: Cumulative (Timer does not reset when                         power comes ON.)

    Basic operation                                                         Detailed operation

                Power

                                                                                                            Power

       Start signal input

                Control     Timing  Sustained  Timing
    ( ) Forecast
                                                                                            Start signal

    output      output 1

    OUT1        OUT1

    ( ) Control
                Control                                                                                     Gate

    output      output 2

    OUT2        OUT2

    (  ) The names in parentheses are used for the absolute value setting.                                  Reset

    • Start signal enables timing (timing is stopped when the               Timing diagram                  999999

    start signal is OFF or when the power is OFF).                                          Set value (SV 2)

    • A sustained control output is used.                                                   Forecast value

    • Timing continues even after the time is up.                                                           (SV 1)

                                                                                                            0

    Note:   Output is instantaneous when the set value is                                                   OUT1

            0.

    When the H5CX is used with power start in mode F

    mode or F-1 (i.e., cumulative operation with output on                                                  OUT2

    hold), there will be a timer error (approximately 100                                   The names               in  parentheses  are  used  for  the  absolute  value  setting.

    ms each time the H5CX is turned ON) due to the

    characteristics of the internal circuitry. Use the H5CX

    with signal start if timer accuracy is required.

Note:       1.  The forecast value = set value - forecast set value

            2.  The forecast set value is used to set the deviation                         for the set value.

40
                                                                                                                             H5CX-@-N

Safety Precautions for All H5CX Series                                     (Common)

                              CAUTION                                      •  Internal elements may be destroyed if a voltage outside the rated

                                                                              voltage range is applied.

Do not allow pieces of metal, wire clippings, or fine                      •  Be sure that polarity is correct when wiring the terminals.

metallic shavings or fillings from installation to enter                   •  Separate the Timer from sources of noise, such as devices with

the product. Doing so may occasionally result in                              input signals from power lines carrying noise, and wiring for I/O

electric shock, fire, or malfunction.                                         signals.

                                                                           •  Do not connect more than two crimp terminals to the same

Minor injury due to explosion may occasionally occur.                         terminal.

Do not use the Timer where subject to flammable or                         •  Up to two wires of the same size and type can be inserted into a

explosive gas.                                                                single terminals.

                                                                           •  Use the specified wires for wiring. Applicable Wires: AWG 18 to

Fire may occasionally occur. Tighten the terminal                             AWG 22, solid or twisted, copper.

screws to the rated torque.                                                •  Install a switch or circuit breaker that allows the operator to

H5CX terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 N •m)                        immediately turn OFF the power, and label it to clearly indicate its

P2CF Socket terminals: 4.4 lb-in (0.5 N •m)                                   function.

                                                                           •  When the Timer is operated with no-voltage input (NPN input),

Minor injury due to electric shock may occasionally                           approximately 14 V is output from the input terminals. Use a sensor

occur. Do not touch any of the terminals while power                          that contains a diode.

is being supplied. Be sure to mount the terminal cover

after wiring.                                                                                    Sensor

                                                                                                                      Diode

The life expectancy of the output relay varies

considerably according to its usage. Use the output

relay within its rated load and electrical life                                                            0V  Input

expectancy. If the output relay is used beyond its life                    •  Use a switch, relay, or other contact so that the rated power supply

expectancy, its contacts may become fused or there may be a                   voltage will be reached within 0.1 seconds. If the power supply

risk of fire. Also, be sure that the load current does not exceed             voltage is not reached quickly enough, the Timer may malfunction

the rated load current and when using a heater, be sure to use a              or outputs may be unstable.

thermal switch in the load circuit.                                        •  Use a switch, relay, or other contact to turn the power supply OFF

                                                                              instantaneously. Outputs may malfunction and memory errors may

Minor electric shock, fire, or malfunction may                                occur if the power supply voltage is decreased gradually.

occasionally occur. Do not disassemble, modify, or                         •  H5CX-A@-N/-L@-N:

repair the Timer or touch internal components.                                When changing the set value during a timing operation, the output

                                                                              will turn ON if the set value is changed as follows because of the

                                                                              use of a constant read-in system:

                Precautions for Safe Use                                      Elapsed time (UP) mode: Present value ≥ Set value

                                                                              Remaining time (DOWN) mode: Elapsed time ≥ Set value (The

•  The panel surface of the H5CX is water-resistant (conforming to            present value is set to 0.)

   NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the                  When in the remaining time mode, the amount the set value is

   internal circuits from water penetration through the space between         changed is added to or subtracted from the present value.

   the H5CX and operating panel, waterproof packing is included.              Operation with a set value of 0 will vary with the output mode. Refer

   Attach the Y92F-30 Adapter with sufficient pressure with the               to the timing charts on page 20.

   reinforcing screws so that water does not penetrate the panel.          •  H5CX-B@-N:

                     0.5 to 1 mm                                              When changing the set value during a timing operation, the output

                              It is recommended that the                      will turn ON if the set value is changed as follows because of the

                              space between the screw                         use of a constant read-in system:

                              head and the Adapter be 0.5                     1. Forecast Value Setting

                              to 1 mm.

                                                                              When the present value ≥ the set value, OUT2 (control output)

•  When mounting the Timer to a panel, tighten the two mounting               turns ON.

   screws alternately, a little at a time, so as to keep them at an equal     When the present value ≥ the forecast value (forecast value =

   tightness. If the panel screws are tightened unequally, water may          set value - forecast set value), OUT1 (forecast output) turns ON.

   enter the panel.                                                           2. Absolute Value Setting

•  Store the Timer at the specified temperature. If the Time has been         When the present value ≥ set value 2, OUT2 (control output 2)

   stored at a temperature of less than -10°C, allow the Time to stand        turns ON.

   at room temperature for at least 3 hours before use.                       When the present value ≥ the forecast value (forecast value =

•  Mounting the Timer side-by-side may reduce the life expectancies           set value - forecast set value), OUT1 (control output 1) turns

   of internal components.                                                    ON.

•  Use the Timer within the specified ranges for the ambient operating        When the set value is 0, the output turns ON the moment the

   temperature and humidity.                                                  signal is input. The reset operation turns OFF the output.

•  Do not use in the following locations:                                  •  Do not use organic solvents (such as paint thinners or benzine),

   •  Locations subject to sudden or extreme changes in                       strong alkali, or strong acids. They will damage the external finish.

      temperature.                                                         •  Confirm that indications are working normally, including the

   •  Locations where high humidity may result in condensation.               backlight LED, and LCD. The indicator LEDs, LCD, and resin parts

•  Do not use the Timer outside of the rated ranges for vibration,            may deteriorate more quickly depending on the application

   shock, water exposure, and oil exposure.                                   environment, preventing normal indications. Periodic inspection

•  Do not use this Timer in dusty environments, in locations where            and replacement are required.

   corrosive gasses are present, or in locations subject to direct         •  The waterproof packing may deteriorate, shrink, or harden

   sunlight.                                                                  depending on the application environment. Periodic inspection and

•  Install the Timer well away from any sources of static electricity,        replacement are required.

   such as pipes transporting molding materials, powders, or liquids.

                                                                                                                                                     41
H5CX-@-N

                     Precautions for Correct Use                                                 Conformance to EN/IEC Standards

    •  H5CX models with a 24-VDC/12 to 24-VDC power supply use a                  •  When conforming to EMC standards, refer to the information

       transformer-free power supply method in which the power supply                provided in this datasheet for cable selection and other conditions.

       terminals are not isolated from the signal input terminals. If a non-      •  This is a class A product. In residential areas it may cause radio

       isolating DC power supply is used, unwanted current paths may                 interference, in which case the user may be required to take

       occasionally burn or destroy internal components depending on                 adequate measures to reduce interference.

       the wiring. Always check the wiring sufficiently before use.               •  H5CX-A@-N/-L@-N:

    •  An inrush current of approx. 10 A will flow for a short time when the         Basic insulation is provided between the power supply and input

       power supply is turned ON. If the capacity of the power supply is             terminals. (No insulation is provided between the power supply and

       not sufficient, the Timer may not start. Be sure to use a power               input terminals for the H5CX-@D-N.)

       supply with sufficient capacity.                                              Basic insulation is provided between power supply and output

    •  Maintain voltage fluctuations in the power supply within the                  terminals, and between input and output terminals.

       specified operating voltage range.                                         •  H5CX-B@-N:

    •  When turning the power ON and OFF, input signal reception is                  No insulation is provided between the power supply and input

       possible, unstable, or impossible as shown in the diagram below.              terminals.

       Power         ON                                                              Basic insulation is provided between the power supply and output

       supply        OFF                                                             terminals.

                            200ms        0 to 50 ms  5ms     0 to 500 ms          •  When double insulation or reinforced insulation is required, apply

                     Input                                                           double insulation or reinforced insulation as defined in IEC 60664

                            Impossible   Unstable  Possible  Unstable Impossible     that is suitable for the maximum operating voltage with clearances

    •  To allow for the startup time of peripheral devices (sensors, etc.),          or solid insulation.

       the Timer starts timing operation between 200 to 250 ms after              •  Connect the input and output terminals to devices that do not have

       power is turned ON. For this reason, in operations where timing               any exposed charged parts.

       starts from power ON, the time display will actually start from 249

       ms. If the set value is 249 ms or less, the time until output turns ON

       will be a fixed value between 200 and 250. The present value

       display will start from 250 ms. (Normal operation is possible for set

       values of 250 ms or more.) In applications where a set value of 249

       ms or less is required, use start timing with signal input.

    •  Inrush current generated by turning ON or OFF the power supply

       may deteriorate contacts on the power supply circuit. Turn ON or

       OFF to a device with the rated current of more than 10 A.

    •  Make sure that all settings are appropriate for the application.

       Unexpected operation resulting in property damage or accidents

       may occur if the settings are not appropriate.

    •  Do not leave the Timer for long periods at a high temperature with

       output current in the ON state. Doing so may result in the

       premature deterioration of internal components (e.g., electrolytic

       capacitors).

    •  EEPROM is used as backup memory when the power is

       interrupted. The write life of the EEPROM is 100,000 writes.

       The EEPROM is written at the following times:

       • When the power supply is turned OFF

       • When switching from Timer/Twin Timer Selection Mode or

       Function Setting Mode to Run Mode

    •  Dispose of the product according to local ordinances as they apply.

    •  Attach the front panel when using the Timer. The tabs in the middle

       of each of four sides secure the front panel to the main body. To

       remove the panel, widen the four tabs and pull the panel toward

       you. To mount the panel, fit all four tabs correctly into the grooves

       on the main body.

                     Tabs

                                                             Grooves

42
Terms and Conditions of Sale

1.   Offer; Acceptance. These terms and conditions (these "Terms") are deemed                              ITY    OR    FITNESS    FOR     A   PARTICULAR       PURPOSE            OF  THE    PRODUCTS.

     part of all quotes, agreements, purchase orders, acknowledgments, price lists,                        BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

     catalogs, manuals, brochures and other documents, whether electronic or in                            PRODUCTS         WILL     SUITABLY       MEET     THE       REQUIREMENTS                OF   THEIR

     writing, relating to the sale of products or services (collectively, the "Products")                  INTENDED USE. Omron further disclaims all warranties and responsibility of

     by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron                                any type for claims or expenses based on infringement by the Products or oth-

     objects to any terms or conditions proposed in Buyer’s purchase order or other                        erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-

     documents which are inconsistent with, or in addition to, these Terms.                                gation   hereunder      shall  be,  at  Omron’s   election,     to  (i)  replace        (in  the  form

2.   Prices; Payment Terms. All prices stated are current, subject to change with-                         originally     shipped  with   Buyer    responsible    for  labor   charges        for  removal   or

     out notice by Omron. Omron reserves the right to increase or decrease prices                          replacement thereof) the non-complying Product, (ii) repair the non-complying

     on any unshipped portions of outstanding orders. Payments for Products are                            Product, or (iii) repay or credit Buyer an amount equal to the purchase price of

     due net 30 days unless otherwise stated in the invoice.                                               the non-complying Product; provided that in no event shall Omron be responsi-

3.   Discounts. Cash discounts, if any, will apply only on the net amount of invoices                      ble for warranty, repair, indemnity or any other claims or expenses regarding

     sent to Buyer after deducting transportation charges, taxes and duties, and will                      the Products unless Omron’s analysis confirms that the Products were prop-

     be allowed only if (i) the invoice is paid according to Omron’s payment terms                         erly handled, stored, installed and maintained and not subject to contamina-

     and (ii) Buyer has no past due amounts.                                                               tion, abuse, misuse or inappropriate modification. Return of any Products by

4.   Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or                         Buyer must be approved in writing by Omron before shipment. Omron Compa-

     the maximum legal rate, whichever is less, on any balance not paid within the                         nies shall not be liable for the suitability or unsuitability or the results from the

     stated terms.                                                                                         use of Products in combination with any electrical or electronic components,

5.   Orders. Omron will accept no order less than $200 net billing.                                        circuits, system assemblies or any other materials or substances or environ-

6.   Governmental Approvals. Buyer shall be responsible for, and shall bear all                            ments. Any advice, recommendations or information given orally or in writing,

     costs involved in, obtaining any government approvals required for the impor-                         are not to be construed as an amendment or addition to the above warranty.

     tation or sale of the Products.                                                                       See http://www.omron247.com or contact your Omron representative for pub-

7.   Taxes. All taxes, duties and other governmental charges (other than general                           lished information.

     real property and income taxes), including any interest or penalties thereon,                    14.  Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE

     imposed directly or indirectly on Omron or required to be collected directly or                       FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

     indirectly by Omron for the manufacture, production, sale, delivery, importa-                         LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY

     tion, consumption or use of the Products sold hereunder (including customs                            WAY     CONNECTED         WITH      THE  PRODUCTS,          WHETHER         SUCH        CLAIM     IS

     duties and sales, excise, use, turnover and license taxes) shall be charged to                        BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

     and remitted by Buyer to Omron.                                                                       Further, in no event shall liability of Omron Companies exceed the individual

8.   Financial. If the financial position of Buyer at any time becomes unsatisfactory                      price of the Product on which liability is asserted.

     to Omron, Omron reserves the right to stop shipments or require satisfactory                     15.  Indemnities. Buyer shall indemnify and hold harmless Omron Companies and

     security or payment in advance. If Buyer fails to make payment or otherwise                           their   employees       from   and  against  all  liabilities,  losses,     claims,     costs     and

     comply with these Terms or any related agreement, Omron may (without liabil-                          expenses (including attorney's fees and expenses) related to any claim, inves-

     ity and in addition to other remedies) cancel any unshipped portion of Prod-                          tigation, litigation or proceeding (whether or not Omron is a party) which arises

     ucts  sold  hereunder   and    stop   any  Products     in  transit  until  Buyer    pays  all        or is alleged to arise from Buyer's acts or omissions under these Terms or in

     amounts,    including   amounts     payable  hereunder,     whether  or     not  then      due,       any way with respect to the Products.        Without limiting the foregoing, Buyer (at

     which are owing to it by Buyer. Buyer shall in any event remain liable for all                        its own expense) shall indemnify and hold harmless Omron and defend or set-

     unpaid accounts.                                                                                      tle any action brought against such Companies to the extent based on a claim

9.   Cancellation;  Etc.    Orders    are  not  subject  to  rescheduling        or  cancellation          that any Product made to Buyer specifications infringed intellectual property

     unless Buyer indemnifies Omron against all related costs or expenses.                                 rights of another party.

10.  Force Majeure. Omron shall not be liable for any delay or failure in delivery                    16.  Property; Confidentiality. Any intellectual property in the Products is the exclu-

     resulting from causes beyond its control, including earthquakes, fires, floods,                       sive property of Omron Companies and Buyer shall not attempt to duplicate it

     strikes or other labor disputes, shortage of labor or materials, accidents to                         in  any  way     without  the   written  permission    of   Omron.       Notwithstanding          any

     machinery, acts of sabotage, riots, delay in or lack of transportation or the                         charges to Buyer for engineering or tooling, all engineering and tooling shall

     requirements of any government authority.                                                             remain the exclusive property of Omron. All information and materials supplied

11.  Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:                            by Omron to Buyer relating to the Products are confidential and proprietary,

     a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship                        and Buyer shall limit distribution thereof to its trusted employees and strictly

          except in “break down” situations.                                                               prevent disclosure to any third party.

     b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall               17.  Export Controls. Buyer shall comply with all applicable laws, regulations and

          constitute delivery to Buyer;                                                                    licenses regarding (i) export of products or information; (iii) sale of products to

     c. All sales and shipments of Products shall be FOB shipping point (unless oth-                       “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of

          erwise stated in writing by Omron), at which point title and risk of loss shall                  regulated technology or information.

          pass from Omron to Buyer; provided that Omron shall retain a security inter-                18.  Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right

          est in the Products until the full purchase price is paid;                                       and no course of dealing between Buyer and Omron shall operate as a waiver

     d. Delivery and shipping dates are estimates only; and                                                of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder

     e. Omron will package Products as it deems proper for protection against nor-                         without Omron's written consent. (c) Law. These Terms are governed by the

          mal handling and extra charges apply to special conditions.                                      law of the jurisdiction of the home office of the Omron company from which

12.  Claims. Any claim by Buyer against Omron for shortage or damage to the                                Buyer    is  purchasing   the     Products   (without  regard       to   conflict  of   law  princi-

     Products occurring before delivery to the carrier must be presented in writing                        ples).   (d) Amendment. These Terms constitute the entire agreement between

     to Omron within 30 days of receipt of shipment and include the original trans-                        Buyer and Omron relating to the Products, and no provision may be changed

     portation bill signed by the carrier noting that the carrier received the Products                    or waived unless in writing signed by the parties. (e) Severability. If any provi-

     from Omron in the condition claimed.                                                                  sion hereof is rendered ineffective or invalid, such provision shall not invalidate

13.  Warranties.    (a)  Exclusive  Warranty.   Omron’s   exclusive       warranty    is  that  the        any other provision. (f) Setoff. Buyer shall have no right to set off any amounts

     Products will be free from defects in materials and workmanship for a period of                       against the amount owing in respect of this invoice. (g) Definitions. As used

     twelve months from the date of sale by Omron (or such other period expressed                          herein, “including” means “including without limitation”; and “Omron Compa-

     in writing by Omron). Omron disclaims all other warranties, express or implied.                       nies” (or similar words) mean Omron Corporation and any direct or indirect

     (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,                                           subsidiary or affiliate thereof.

     EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1.   Suitability of Use. Omron Companies shall not be responsible for conformity                           ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-

     with any standards, codes or regulations which apply to the combination of the                        ERLY     RATED   AND      INSTALLED      FOR      THE  INTENDED             USE    WITHIN         THE

     Product in the Buyer’s application or use of the Product. At Buyer’s request,                         OVERALL EQUIPMENT OR SYSTEM.

     Omron will provide applicable third party certification documents identifying                    2.   Programmable Products. Omron Companies shall not be responsible for the

     ratings and limitations of use which apply to the Product. This information by                        user’s programming of a programmable Product, or any consequence thereof.

     itself is not sufficient for a complete determination of the suitability of the Prod-            3.   Performance      Data.    Data    presented  in   Omron     Company         websites,        catalogs

     uct in combination with the end product, machine, system, or other application                        and other materials is provided as a guide for the user in determining suitabil-

     or use. Buyer shall be solely responsible for determining appropriateness of                          ity and does not constitute a warranty. It may represent the result of Omron’s

     the particular Product with respect to Buyer’s application, product or system.                        test conditions, and the user must correlate it to actual application require-

     Buyer shall take application responsibility in all cases but the following is a                       ments. Actual performance is subject to the Omron’s Warranty and Limitations

     non-exhaustive list of applications for which particular attention must be given:                     of Liability.

     (i)   Outdoor use, uses involving potential chemical contamination or electrical                 4.   Change       in  Specifications.    Product  specifications     and      accessories         may  be

     interference, or conditions or uses not described in this document.                                   changed at any time based on improvements and other reasons. It is our prac-

     (ii)  Use in consumer products or any use in significant quantities.                                  tice to change part numbers when published ratings or features are changed,

     (iii) Energy control systems, combustion systems, railroad systems, aviation                          or when significant construction changes are made. However, some specifica-

     systems, medical equipment, amusement machines, vehicles, safety equip-                               tions of the Product may be changed without any notice. When in doubt, spe-

     ment, and installations subject to separate industry or government regulations.                       cial part numbers may be assigned to fix or establish key specifications for

     (iv) Systems, machines and equipment that could present a risk to life or prop-                       your application. Please consult with your Omron’s representative at any time

     erty. Please know and observe all prohibitions of use applicable to this Prod-                        to confirm actual specifications of purchased Product.

     uct.                                                                                             5.   Errors and Omissions. Information presented by Omron Companies has been

     NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS                                            checked and is believed to be accurate; however, no responsibility is assumed

     RISK  TO     LIFE   OR  PROPERTY         OR  IN  LARGE      QUANTITIES           WITHOUT              for clerical, typographical or proofreading errors or omissions.

     ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
            ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

            To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS

                  Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON CANADA, INC. • HEAD OFFICE                                  OMRON ARGENTINA • SALES OFFICE

Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca  Cono Sur • 54.11.4787.1129

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE                     OMRON CHILE • SALES OFFICE

São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br        Santiago 56.2206.4592

OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE                   OTHER OMRON LATIN AMERICA SALES

Apodaca, N.L. • 52.811.156.99.10 • mela@omron.com                 56.2206.4592

L111-E1-01  7/09  Note: Specifications are subject to change.     © 2008 Omron Electronics LLC                           Printed in U.S.A.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

H5CX-A-N AC100-240      H5CX-A11-N AC100-240  H5CX-ASD-N-DC12-24/AC24  H5CX-L8D-N DC12-24/AC24   H5CX-

AD-N AC24/DC12-24  H5CX-L8-N AC100-240  H5CX-A11SD-N DC12-24/AC24      H5CX-L8ED-N DC12-24/AC24  H5CX-

L8S-N AC100-240  H5CX-A11D-N DC12-24/AC24     H5CX-AS-N AC100-240  H5CX-L8SD-N DC12-24/AC24  H5CX-L8D-

N AC12-24/AC24   H5CX-BWSD-N DC12-24    H5CX-L8E-N AC100-240  H5CX-A11S-N AC100-240  H5CX-A-AC100-240

H5CX-A AC100-240 CALIBRATED  H5CX-AD-AC24/DC12-24  H5CX-L8-AC100-240   H5CX-A11-AC100-240        H5CX-

A11D-AC24/DC12-24

小广播

H5CX-ASD-N-DC12-24-AC24器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved