电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

H5CN-YBN AC100-240

器件型号:H5CN-YBN AC100-240
器件类别:热门应用    机电/工控/自动化   
文件大小:24370.9KB,共15页
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

控制器 timer digital led

参数
制造商: Omron
产品种类: 控制器
RoHS:

H5CN-YBN AC100-240器件文档内容

Digital Timer                                                      CSM_H5CN_DS_E_2_1

H5CN

Miniature DIN-sized (48 x 48 mm) Quartz
Timer with Abundant Series Versions

Series version cover a wide range of rated times; 9.999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.

Selection of elapsed time indication, remaining time indication,
contact output, and solid-state output types to suit require-
ments.

Power supply freely selectable within a range of 100 to
240 VAC, as well as 12 to 48 VDC.

Certified for UL and CSA safety standards.

        Refer to Safety Precautions for All Timers.
        Refer to Safety Precautions on page 13

Model Number Structure

Model Number Legend

Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 2 for avail-
        ability.

H5CN- @@N@@                                                         3. Output mode
                                                                        N: N mode (Power ON-delay)
                1 234 5
                                                                    4. Backup power supply function for memory protection
1. Display                                                              None: Not provided
    X: UP display (increments from 0 to the set time)                   M: Provided
    Y: DOWN display (decrements from the set time to 0)
                                                                    5. Output type
2. Rated time                                                           None: Contact output (SPDT)
    Z: 0.001 to 9.999 s                                                 S: Solid-state output
    A: 0.001 to 99.99 s
    B: 0.1 to 999.9 s
    C:1 s to 99 min 59 s
    D:1 min to 99 h 59 min

                                                                                                                                                    1
                                                                                                        H5CN

Ordering Information

List of Models

Display type                              UP display timer (increments form DOWN display timer (decre-  UP display timer (increments from 0
                                                                                                        to the set time)
Output type                               0 to the set time)          ments form the set time to 0)     Solid-state output
Pin type
Backup power supply function for          Contact output (SPDT)                                         12 to 48 VDC
memory protection                                                                                       H5CN-XZNS
                                          11-pin              8-pin                                     H5CN-XANS
Supply voltage                                                                                          ---
Rated time 0.001 to 9.999 s               Uses external Not provided                                    ---
                                          battery (lithium).                                            ---
                    0.001 to 99.99 s      (See notes 2 and
                    0.1 to 999.9 s        3.)
                    1 s to 99 min 59 s
                    1 min to 99 h 59 min  100 to 240 VAC 100 to 240 VAC, 12 to 48 VDC

                                          ---                 ---     ---

                                          H5CN-XANM H5CN-XAN H5CN-YAN

                                          H5CN-XBNM H5CN-XBN H5CN-YBN

                                          H5CN-XCNM H5CN-XCN H5CN-YCN

                                          H5CN-XDNM H5CN-XDN H5CN-YDN

Note: 1. Specify both the model number and supply voltage when ordering.
             Example: H5CN-XAN 12 to 48 VDC

                                                   Supply voltage

2. The Y92S-20 Backup Battery (sold separately) provides power backup for memory protection during power failures for approximately
    5 years (at 20C). Always connect a battery to the H5CN-X@NM. For details on connection methods, refer to page 5.

3. The H5CN-X@NM does not support power resetting.

Accessories (Order Separately)

                      Name                                       Models
                                                  Y92F-30
Flush Mounting Adapter                            Y92S-20
                                                  P2CF-08
Backup Battery                                    P2CF-11
                                                  P3G-08
Track Mounting/Front    8-pin                     P3GA-11
Connecting Socket       11-pin                    Y92A-48B
                                                  Y92A-48D
Back Connecting Socket 8-pin                      PFP-50N
                                                  PFP-100N
                        11-pin                    PFP-100N2
                                                  PFP-M
Protective Cover        Hard Cover                PFP-S

                        Soft Cover

Mounting Track          50 cm (I) 7.3 mm (t)

                        1 m (I) 7.3 mm (t)

                        1 m (I) 16 mm (t)

End Plate

Spacer

                                                                                                                                             2
                                                                                                                                  H5CN

Specifications

Ratings

         Item               Contact output                                                Solid-state output

Rated supply voltage 100 to 240 VAC (50/60 Hz), 12 to 48 VDC (permissible rip- 12 to 48 VDC (permissible ripple: 20% max.)
                                   ple: 20% max.) (See note 1.)

Operating voltage range 85% to 110% of rated supply voltage

Power consumption     Approx. 12 VA at 240 VAC, 50 Hz                                     Approx. 2.5 W at 48 VDC
                      Approx. 2.5 W at 48 VDC

Mounting method       Surface mounting or flush mounting

Display               7-segment LEDs (8-mm-high characters), UP indicator

Input method          Contact open and short-circuit input                                Open-collector transistor ON/OFF input

Resetting system and  Reset by power-OFF (See note 2.):
gate input            min. power OFF time: 0.5 s
                      External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s;
                      residual voltage: 2 V max.

Output mode           N mode (Power ON-delay)

Control outputs       SPDT: 3 A at 250 VAC, resistive load (cos = 1)                      Open collector: 100 mA max. at 30 VDC max.

Ambient temperature Operating:10C to 55C (with no icing or condensation)
                                   Storage:25C to 65C (with no icing or condensation)

Ambient humidity      Operating: 35% to 85%

Case color            Light gray (Munsell 5Y7/1)

Note: 1. Models with memory backup function are available only for AC power.
        2. The H5CN-X@NM cannot be reset by turning OFF the power.

Characteristics

Accuracy of operating time  0.01% 0.05 s max. (see note 1), 0.005% 0.03 s max. (see note 2) (see note 3)
Setting error
Influence of voltage        100 M min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying
Influence of temperature    metal parts, between power supply circuit and control output circuit)
Insulation resistance       2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non-current-carrying
                            metal parts, between power supply circuit and control output circuit)
Dielectric strength         6 kV (between power supply terminal)
                            6 kV (between current-carrying terminal and exposed non-current carrying metal parts)
Impulse withstand voltage   Square-wave noise by noise simulator
                            AC: 2 kV (between power supply terminals)
Noise immunity              DC: 480 V (between power supply terminals), 500 V (between input terminals)
                            Malfunction: 8 kV
Static immunity             Destruction:10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each
Vibration resistance        Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each
                            Destruction:300 m/s2 3 times each in 6 directions
Shock resistance            Malfunction:100 m/s2 3 times each in 6 directions
                            Mechanical:10,000,000 operations min.
Life expectancy             Electrical:100,000 operations min. (3 A at 250 VAC, resistive load)
                            UL508, CSA C22.2 No. 14
Approved standards          Approx. 200 g
Weight

Note: 1. When timer operation is started by power application.

        2. When timer operation is started after a reset input has been applied.

        3. These values represent the total accuracy of the timer including the repeat accuracy, setting error, and variation due to voltage and tem-
            perature changes. Note that they also comprise errors due to the rise time of the power source and the operating times of the internal
            and output circuits.

                                                                                                                                                       3
                                                                                           H5CN

Life-test Curve (Reference Values)Number of switching operations (104 times)

      1,000
       700
       500

       300

                                             100

                                             70

                                             50

                                             30      30 VDC cos =1

                                                                        250 VAC cos =1

                                             10
                                                   250 VAC cos =0.4
                                             7
                                                                     30 VDC L/R = 7 ms
                                             5

                                             0    1                  2  3               4

                                Load current (A)

A maximum current of 0.15A can be switched at 125 VDC (cos = 1)

Maximum current of 0.1 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected. The minimum
applicable load is 10 mA at 5 VDC (failure level: P reference value).

                                                                                                 4
                                                                                                                                 H5CN

Connections

Block Diagram

H5CN-@@N (without Backup Power for Memory Protection)

Using an AC Power Supply (Contact Outputs)

                          Thumbwheel               One-shot timer
                          switch                   circuit

           Initial clear  Microcomputer-                  Clock    7-segment
           circuit        type custom LSI  Timer circuit           indicator

            Quartz-                                                 Output
            crystal                                                 circuit
            oscillator
                                  Reset input Gate input
              Filter
                          Filter           Filter

                                                                   UP display

Constant-                                                                      Note: 1. If the reset input is short-circuited (be-
voltage                                                                                    tween terminals A and C), immediately
circuit                                                                                    the count circuit is reset to 0 and the con-
                                                                                           trol output relay is reset to OFF. The tim-
Rectifier                                                                                  er starts as soon as the reset input is
circuit                                                                                    opened (between terminals A and C).

                                                                                       2. If the gate input is short-circuited (be-
                                                                                           tween terminals A and D), the count cir-
                                                                                           cuit stops immediately. The timer then
                                                                                           restarts as soon as the gate input is
                                                                                           opened (between terminals A and D).

Using a DC Power Supply (Solid-state Outputs)

Note: The following block diagram shows the differences for the equivalent section indicated by "a" in the above block diagram.

                          Reset input Gate input                              Note: Terminals A and B are internally short-circuited.

           Filter         Filter           Filter

Constant-
voltage
circuit

  Power
  supply
  circuit

                                                                                                                                         5
                                                                                     H5CN

H5CN-X@NM (with Backup Power for Memory Protection)

Note: Be sure to install a Backup Battery (sold separately).

                          Thumbwheel        One-shot timer
                          switch            circuit

           Power failure                            Clock          7-segment
           detection                                               indicator
           circuit
                          Microcomputer-    Timer circuit          Output
            Quartz-       type custom LSI                          circuit
            crystal
            oscillator                     Gate input Reset input  UP indicator lit  Note: 1. If the reset input is short-circuited (be-
                                                                                                 tween terminals C and G), immediately
               Filter               Filter  Filter                                               the count circuit is initialized and the con-
                                                                                                 trol output relay is reset to OFF. The timer
Constant-                 External                                                               starts as soon as the reset input is opened
voltage                   battery                                                                (between terminals C and G).
circuit
                                                                                             2. If the gate input is short-circuited (be-
                                                                                                 tween terminals C and E), the count cir-
                                                                                                 cuit stops immediately. The timer then
                                                                                                 restarts as soon as the gate input is
                                                                                                 opened (between terminals C and E).

Rectifier
circuit

                                                                                                                                                6
                                                                                                                       H5CN

Installation

Connections                                                                 Connecting of Load Circuit
                                                                             Load 1 connected in series with NO contact (between terminals F
1. Battery Connection (H5CN-X@NM                                             and H) is normally open, and the load circuit voltage will be applied
Only)                                                                        after the lapse of the set time. The load circuit voltage is normally
                                                                             applied to load 2 connected in series with NC contact (between ter-
Model with Backup                                                            minals E and H), which will be open after the lapse of the set time.
Power for Memory
Protection                                                                                                                        Load 2

Connect the Y92S-20 Backup Bat-      External                                          Load 1  Load circuit voltage
tery between terminals A and D,      battery 3 V                                               (250 VAC, 30 VDC max.)
making sure the polarities are cor-
rect.                                                                        Note: The maximum load current is 3 A (resistive load).

2. Power Supply Connection                                                   Solid-state Output Type

Model without Backup Power for Memory                                        Internal Circuit of Control Output
Protection                                                                   Terminals F and H are an open collector output. A diode is inter-
                                                                             nally connected between terminals E and F to absorb counterelec-
Connect the timer so that the required supply voltage can be applied         tromotive force that occurs when an inductive load is connected.
across terminals B and G. (Make sure that the polarity of the DC
power supply is correct.)

AC Power Supply                      DC Power Supply

                                                                             Connection of Load Circuit
                                                                             Voltage is applied to the load after the set time has lapsed.

                                     12 to 48 VDC

100 to 240 VAC

Model with Backup Power for Memory                                                             Load
Protection (H5CN-X@NM)
                                                                                                     Load voltage
Connect the timer so that the required supply voltage can be applied                                 (30 VDC max.)
across terminals B and J.

                                                  External                   Note: The maximum load current is 100 mA.
                                                   battery
                                                                             Model with Backup Power for Memory
                                                             100 to 240 VAC  Protection (H5CN-X@NM)

3. Connection of Load Circuit (Control                                       Contact Output Type
Output)
                                                                             Internal Circuit of Control Output Contacts
Model without Backup Power for Memory                                        Terminal H, I, and K are for control output contacts.
Protection
                                                                             External
Contact Output Type                                                          battery

Internal Circuit of Control Output
Contacts
Terminals E, F, and H are for con-
trol output contacts.

                                                                                                                                                    7
Connection of Load Circuit                                                                                                   H5CN
Load 1 connected in series with NO contact (between terminals I
and K) is normally open, and the load circuit voltage will be applied                   5. Connection of Gate Input
to it after the lapse of the set time. The load circuit voltage is normally
applied to load 2 connected in series with NC contact (between ter-                     Connection of the gate input contact or an open collector transistor
minals H and K), which will be open after the lapse of the set time.                    between terminals A and D (between terminals C and E for mod-
                                                                                        els with backup power for memory protection) permits the timer to
                                                             Load 2                     stop operation while contact is made or the transistor turns ON. Use
                                                                                        of a high-reliability gold-plated contact is recommended for the gate
                           Load 1  Load circuit                                         input. For the gate input transistor, select the one satisfying the fol-
                                   voltage                                              lowing electrical ratings:
External                           (250 VAC,                                            VCEO = 20 V min.
battery                            30 VDC max.)                                         IC = 50 mA min.
                                                                                        ICEO (leakage current) = 0.1 mA max.
        Note: The maximum load current is 3 A (resistive load).                         VCE(sat) (residual voltage) = 2 V max.
                                                                                        Use a gate input contact with a short bounce time because the con-
4. Connection of Reset Input                                                            tact bounce time causes an error in the operate time of the timer for a
                                                                                        period equalling the bounce time.
Connection of the reset input contact or an open collector transistor
between terminals A and C (between terminals C and G for mod-                           Model without Backup Power for Memory
els with backup power for memory protection) permits the timer to                       Protection
reset when contact is made or the transistor turns ON. Use of a high-
reliability gold-plated contact is recommended for the reset input. For                                             Gate input contact
the reset input transistor, select the one satisfying the following elec-                                           (Timer stops when
trical ratings:                                                                                                     contact is made.)
VCEO = 20 V min.
IC = 50 mA min.                                                                                                   Gate input transistor
ICEO (leakage current) = 0.5 A max.                                                                              (Timer stops when
VCE(sat) (residual voltage) = 2 V max.                                                                            transistor is ON.)

Model without Backup Power for Memory                                                   Model with Backup Power for Memory
Protection                                                                              Protection (H5CN-X@NM)

          Reset input                                                                                                 Gate input contact
          contact                                                                                                     (Timer stops when
          (Timer resets                                                                                               contact is made.)
          when contact is
          made.)                                                                                                                                                           External
                                                                                                                                                                           battery
                             Reset input
                             transistor                                                                          Gate input transistor
                             (Timer resets                                                                       (Timer stops when
                             when transistor                                                                     transistor is ON.)
                             is ON.)
                                                                                                                                                                           External
Model with Backup Power for Memory                                                                                                                                         battery
Protection (H5CN-X@NM)
                                                                                        6. Battery Connections when Using
                                   Reset input                                          Backup Power for Memory Protection
                                   contact
                                   (Timer resets                                        Always connect a battery when using models with backup power for
                                   when contact is                                      memory protection (H5CN-X@NM). Any 3-V battery can be used, but
                                   made.)                                               the backup time will depend on the capacity of the battery.
                                                                                        When using the Unit for the first time after purchase, apply power
                                                                              External  and reset the Unit once before using it. When power is turned ON for
                                                                              battery   the first time, outputs may be produced at the same time, so do not
                                                                                        connect the output terminals.
                               Reset input                                              When connecting the battery using a Socket (P2CF-11 or P3GA-11),
                               transistor                                               check the terminal numbers on the Socket and connect the positive
                               (Timer resets                                            side of the battery to terminal D and the negative side to terminal A.
                               when transistor
                               is ON.)

                                                                              External
                                                                              battery

                                                                                                                                                                                     8
Operation                            Time up    DOWN Display                                                                                                                                           H5CN

Timing Chart                                                           Power ON                                                                                                                 Time up
                                                       Reset input
Digital Display                      No digital         Gate input
                                        display      Setting value
      UP Display                                                                                                                                                                     No digitalDigital display
                                                                                                                                                                                        display
                           Power ON                                 0
         Reset input                                Power supply
           Gate input
       Setting value                               Control output
       Digital display
                                              Time up indication
                       0
      Power supply

      Control output

Time up indication

                                                                                                                                                                                                             9
                                                                                                                           H5CN

Dimensions

Note: All units are in millimeters unless otherwise indicated.

Dimensions without Flush Mounting Adapter

H5CN-X@N/-Y@N/-X@NS (Flush Mounting/Surface Mounting Models)

                                                                                       44.8 44.8

                                                                                 

                                                                                        8 pins

H5CN-X@NM (Flush Mounting/Surface Mounting Models)

                                                                                       44.8 44.8

                                                                                 

                                                                                 11 pins

Dimensions with Flush Mounting Adapter

H5CN-X@N/-Y@N/-X@NS (Adapter Ordered Separately)                                                    Panel Cutout

                                                    Panel  Y92F-30 (order separately)               The standard panel cutout is as below.
                                                           Flush Mounting Adapter
                                                                                                    (Panel cutout conforms to DIN 43700.)
                                                                 P3G-08 (order separately)
                                                                 Back Connecting Socket                       45  +0.6
                                                                                                                  -0

                                                                                                    45  +0.6
                                                                                                        -0

                                                                                                    Gang-mounting of more than 2 units
                                                                                                    (horizontally)

                                                                           95.1

                                                                                                    45  +0.6
                                                                                                        -0

H5CN-X@NM (Adapter Ordered Separately)                                                                                           N
                                                                                                  Note: 1. Panel thickness: 1 to 5 mm
                                                    Panel  Y92F-30 (order separately)
                                                           Flush Mounting Adapter                           2. When gang-mounting the Unit, the
                                                                                                                 orientation of the Adapter must be
                                                                  P3GA-11 (order separately)                     changed depending on whether
                                                                  Back Connecting Socket                         Units are mounted horizontally or
                                                                                                                 vertically.

                                                                                                            3. No cover:
                                                                                                                 N = (48n - 2.5) /+1 -0
                                                                                                                 With hard cover:
                                                                                                                 N = {48n - 2.5 + (n - 1) x 3} /+1 -0

Dimensions with Front Connecting Socket

                                                                                  Flush Mounting

H5CN       H5CN                                                                  H5CN                             H5CN
-X@N,Y@N,  -X@NM                                                                 -X@N, Y@N,                       -X@NM
X@NS                                                                             X@NS
            P2CF-11                                                                                                   +
P2CF-08                                                                               +                          adapter
                                                                                   adapter

Note: These dimensions vary with the kind of DIN track (reference value).

                                                                                                                                                       10
                                                                                                                                                       H5CN

Accessories (Order Separately)

Note: All units are in millimeters unless otherwise indicated.

Track Mounting/Front Connecting Socket

P2CF-08  Eight,                                             7.8     3             4.5                 Terminal Arrangement/
                                                                                                      Internal Connections
         M3.5 x 7.5 sems                                                                              (Top View)

                                                                                                                             Surface Mounting Holes

                                                                                                                             Two, 4.5 dia. or two, M4

         70 max.                                                                            35.4

                                                            Two, 4.5 dia.                                                    400.2
                                                            holes

         4
                          50 max.

                                                                    20.3 max.

Track Mounting/Front Connecting Socket

P2CF-11  Eleven,                                                 3                4.5                 Terminal Arrangement/
                                                                                                      Internal Connections
         M3.5 x 7.5 sems                                    7.8                                       (Top View)             Surface Mounting Holes

                                                                                                                              Two, 4.5 dia. or two, M4

                                          70 max.                                               35.4                         400.2

                                            4               Two, 4.5 dia.
                                                            holes
Back Connecting Socket
P3G-08                                             50 max.

                                                                       31.2 max.

                                                   27 dia.                                            Terminal Arrangement/
                                                                                                      Internal Connections
                                                                                                      (Bottom View)

         45

                        45                                       4.9   17
                     27 dia.
P3GA-11  45                                                                                 Terminal Arrangement/
                                                                                            Internal Connections
                        45                                                                  (Bottom View)

                                                                                  25.6

                                                                 4.5   16.3       6.2

                                                                                                                                                        11
                                                                                                                                                  H5CN

Backup Battery                                                     22.5 dia. Red lead wire (0.18 12 conductors)
Y92S-20                                                                          L=120 mm

Soft Cover                                                                           Note: Always connect a battery to models with
Y92A-48D (See note 1.)                                                                       backup power for memory protection
                                                                                             (H5CN-@M).
Flush Mounting Adapter
Y92F-30                                                        4.5 dia. hole

                                             Hard Cover
                                             Y92A-48B (See note 2.)

                                                                              Note:  1. The soft protective cover allows the set value to be set by
                                                                                        depressing the thumbwheel switches through it. It may be,
                                                                                        however, difficult to make setting changes of the Timer
                                                                                        with the Y92A-48D Protective Cover attached, which must
                                                                                        be taken into consideration before using the Y92A-48D
                                                                                        Protective Cover.

                                                                                     2. The hard protective cover prevents the set value from
                                                                                         being altered due to accidental contact with the push
                                                                                         type thumbwheel switch.

Mounting Track                                                     PFP-100N2
PFP-100N, PFP-50N

                                                                                                                                              16

4.5                                          7.30.15              4.5
                                               350.3
                                                          270.15                                                     350.3 27 24                29.2
                                                                                                                                           1      1.5
     15 25      25  25                 25 *                 1             15 25 25          25 25 15
                                                                                                 10
            10      1,000 (500) 10                                            10     1,000

                    (See note.)

     Note: The values shown in parentheses are for the PFP-50N.

End Plate                                                             Spacer                                                16
PFP-M                                                                 PFP-S

                                                       10                                                          5        12
                                                       6.2 1.8

                                                       1

                    50                                    1.8  35.5 35.3                                              44.3        34.8

                                 11.5                  1.3

                                       10 M4 x 8       4.8                                                                  16.5
                                            pan head

                                       screw

                                                                                                                                                        12
                                                                                                                        H5CN

Safety Precautions                                                          Setting of Operating Time

Refer to Safety Precautions for All Timers.                                 Time Setting Range

                           !WARNING                                                       Setting range                  Models
                                                                            0.001 to 9.999 s               H5CN-@Z@
The Y92S-20 Backup Battery used for the H5CN-X@NM is a lithium              0.01 to 99.99 s                H5CN-@A@
battery (non-explosion-proof). Do not short-circuit the positive and        0.1 to 999.9 s                 H5CN-@B@
negative sides of the battery, recharge or disassemble the battery,         1 s to 99 min 59 s             H5CN-@C@
deform the battery under pressure, or dispose of the battery in fire.       1 min to 99 h 59 min           H5CN-@D@
Doing so may occasionally cause the battery to burst, ignite, or leak.
Use only the specified battery. Otherwise, the battery may leak or          1. The H5CN Timer is capable of reading the input data at any time
burst, occasionally causing damage to the equipment or minor injury.            during normal operation. This means that the set time can be
                                                                                changed during power application. This feature sets back the
Precautions for Correct Use                                                    output from the timer by temporarily setting the longer time or
                                                                                quickens the output by setting the shorter time. During normal
Battery Connections when Using                                                  operation, the set time may be accidentally changed by touching
Backup Power for Memory Protection                                              a thumbwheel switch. To prevent this possibility, use the optional
                                                                                Y92A-48@ Protective Cover.
Always connect a battery when using models with backup power for
memory protection. Any 3-V battery can be used, but the backup              2. When the set time is all zeroes (e.g., 000.0 s or 00 h 00 min),
time will depend on the capacity of the battery. When using the Unit            there will be a momentary control output upon power application,
for the first time after purchase, apply power and reset the Unit once          which can be used to check normal output. When changing the
before using it. When power is turned ON for the first time, outputs            set time during normal operation, pay special attention not to alter
may be produced at the same time, so do not connect the output                  the set value to this all zeroes.
terminals.
If a power interruption continues for 10 minutes or more when a             3. When changing the set time while power is being supplied, an
battery is not connected, the count value and displays may be                   inadequate push of the thumbwheel switches will display two
meaningless, and outputs may be produced unpredictably even if the              numbers in one digital display window, causing the operating time
power supply recovers. If this happens, apply power to the reset input          to drift widely. Therefore, press the thumb-wheel switches surely.
once before using the Unit further. (The Unit can be used after                 Take particular care when the other three digits are all zeroes,
turning ON the reset input, regardless of whether a battery is                  because the improper setting of the fourth switch to create four
connected or not.)                                                              zeroes will cause an instantaneous output.
Regular battery replacement (every 4 to 5 years) is recommended.
The life of the battery depends on the frequency of power failures.         Undesirable Setting

                               Y92S-20 or                                                      min sec         hours min
                               equivalent 3-V battery
                                                                            Changing unwanted
Connection Methods                                                          settings

                                                                            Conceivable        5 min 30 s         00h00min
                                                                            operating time                     (Instant output)
                    Y92S-20
To terminal No. 1                     To terminal No. 4                     4. Take particular care with the H5CN-@Z@, which is capable of
                                                                                setting in 1/1000th of a second because there is an error of
                             P2CF-11                                            between 0.03 to 0.05 ms. (Repeat accuracy is 1 to 2 ms.)

To terminal No. 4                                Y92S-20                    Operation Examples
                                                         To terminal No. 1
                                                                            During Incremental Operation
                             P3GA-11                                          If the set value is changed to a value higher than the currently
                                                                              displayed present value, the timer will time out for the new set
                                                                              value.

                                                                            During Decremental Operation
                                                                              When the set value changes, the difference between the new set
                                                                              value and old set value will be added or subtracted from the
                                                                              present value.

                                                                            Example:

                                                                            Old set value                New set value

                                                                                               200 s -> 100 s

                                                                                          Present value  Present set value
                                                                            (before changing setting)    (after changing setting)

                                                                                               160 s -> 60 s

                                                                                                                                                13
                                                                                                                H5CN

Power Supply

Leave the power supply OFF for at least 0.5 s before turning it back
ON (power supply reset).

Inputs and Outputs

Do not apply voltage externally to input terminals A, C, and D.
When using contacts for the reset input and gate input, use gold-

  plated contacts with good contact reliability. Use gate input
  contacts with short contact bounce (chattering).

Operation during Power Failures

When Units without backup power for memory protection are used,
  the timer status during momentary power failures is as shown in the
  following diagrams.

A. Power Failure of 0.01 s Max.

m-2 m-1 m     m+1 m+2

                                              Power failure
                                                    *Restarts from status before power failure.

B. Power Failure of 0.5 s Min.

m-2 m-1 m                               123

                      Power failure
              *Restarts from initial status after power reset.

C. Power Failure of 0.01 to 0.5 s Max.

m-2 m-1 m                        m m+1 m+2
                                 123

                                                  Power failure

                                                                      *Either A or B are undefined.

Units with backup power for memory protection will restart from the
  status before the power failure as shown in example A, regardless
  of the length of time of the power failure.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                      14
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2008.11
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2008 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved