Solid-state Timer                                                                                             CSM_H3Y_DS_E_2_1

H3Y

Miniature Timer Compatible with the MY
Relay

Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting.

A flat-blade and Phillips screwdriver can also be used for
time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN61812-1 and approved by UL and CSA.

Ordering Information

Operation/        Time-limit contact   Time ranges                    Supply voltage                        Mounting

resetting system                                                                          Surface/DIN-track Surface mounting

                                                                                                  mounting     (with PCB terminals)

                                                                                          (with socket)

Time-limit operation/ DPDT (for power  0.04 s to 3 h        24, 100 to 120, 200 to 230 VAC H3Y-2               H3Y-2-0
                                                                                                               H3Y-4-0 (See note 3.)
self-resetting    switching)                                (50/60 Hz);

                  4PDT                                      12, 24, 48, 125, 100 to       H3Y-4 (See note 3.)
                                                            110 VDC

Note: 1. Specify both the model number, supply voltage, and rated time when ordering.

        Ex. H3Y-2 100 to 120 VAC 0.5 s

                                                              Rated time
                                                              Supply voltage
        2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.
        3. Use the H3Y-4 or H3Y-4-0 Series when switching micro loads.

Accessories (Order Separately)

         Timer       Track-mounted Socket (See note.)                                 Back-connecting Socket

H3Y-2             PYF08A, PYF08A-N, PYF08A-E                      Solder terminal     Wire-wrap terminal       PC terminal
H3Y-4             PYF14A, PYF14A-N, PYF14A-E                PY08
                                                            PY14                      PY08QN(2)                PY08-02

                                                                                      PY14QN(2)                PY14-02

Note: Track-mounted Socket can be used as a front-connecting socket.

Specifications

Time Ranges

       Rated time                       Time setting range                    Rated time                         Time setting range
                              0.04 to 0.5 s                                                             0.1 to 3 min
0.5 s                         0.1 to 1 s                              3 min                             0.2 to 5 min
1s                            0.2 to 5 s                              5 min                             0.5 to 10 min
5s                            0.5 to 10 s                             10 min                            1 to 30 min
10 s                          1.0 to 30 s                             30 min                            2 to 60 min
30 s                          2.0 to 60 s                             60 min                            0.1 to 3 h
60 s                          5.0 to 120 s                            3h                                ---
120 s                                                                 ---

                                                                                                                                      1
                                                                                                           H3Y

Ratings

                       Item                          H3Y-2(-0)/H3Y-4(-0)
Rated supply voltage (See note 6.)
Operating voltage range             24, 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz) (See note 1.), 12, 24, 48, 125, 100 to 110 VDC
Reset voltage                       (See notes 2 and 3.)
Power consumption
                                    All rated voltages except 12 VDC: 85% to 110% of rated supply voltage
Control outputs                     12 VDC: 90% to 110% of rated supply voltage (See note 4.)

                                    10% min. of rated supply voltage (See note 5.)

                                    100 to 120 VAC:  Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
                                    200 to 230 VAC:  Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
                                    24 VAC:          Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
                                    12 VDC:          Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
                                    24 VDC:          Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
                                    48 VDC:          Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
                                    100 to 110 VDC:  Relay ON: Approx. 1.1 W at 12 VDC
                                    125 VDC:         Relay OFF: Approx. 0.1 W at 12 VDC
                                                     Relay ON: Approx. 1.1 W at 24 VDC
                                                     Relay OFF: Approx. 0.1 W at 24 VDC
                                                     Relay ON: Approx. 1.2 W at 48 VDC
                                                     Relay OFF: Approx. 0.3 W at 48 VDC
                                                     Relay ON: Approx. 1.6 W at 110 VDC
                                                     Relay OFF: Approx. 0.4 W at 110 VDC
                                                     Relay ON: Approx. 1.6 W at 125 VDC
                                                     Relay OFF: Approx. 0.4 W at 125 VDC

                                    H3Y-2(-0): 5 A at 250 VAC, resistive load (cos = 1)
                                    H3Y-4(-0): 3 A at 250 VAC, resistive load (cos = 1)

Note: 1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details.

        2. With DC ratings, single-phase full-wave rectified power sources may be used.

        3. Only the H3Y-2 and H3Y-2-0 Series include 2-VDC models.

        4. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient
            operating temperature of 50C.

        5. Set the reset voltage as follows to ensure proper resetting.
                   100 to 120 VAC:10 VAC max.
                   200 to 230 VAC:20 VAC max.
                   100 to 110 VDC:10 VDC max.

        6. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor.

                                                                                                                                              2
                                                                                                                             H3Y

Characteristics

Accuracy of operating time         1% FS max. (0.5 s range: 1%10 ms max.)

Setting error (see note 1)         10%50 ms FS max.

Reset time                         Min. power-opening time: 0.1 s max. (including halfway reset)

Reset voltage                      10% max. of rated supply voltage

Influence of voltage (see note 1)  2% FS max.

Influence of temperature (see note 1) 2% FS max.

Insulation resistance              100 M min. (at 500 VDC)

Dielectric strength                2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying
                                   metal parts) (see note 2)
                                   2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) (see note 2)
                                   2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) (see note 2)
                                   1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
                                   1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance               Destruction: 10 to 55 Hz, 0.75-mm single amplitude
                                   Malfunction: 10 to 55 Hz, 0.5-mm single amplitude

Shock resistance                   Destruction: 1,000 m/s2 (approx. 100G)
                                   Malfunction: 100 m/s2 (approx. 10G)

Ambient temperature                Operating: 10C to 50C (with no icing)

                                   Storage:        25C to 65C (with no icing)

Ambient humidity                   Operating: 35% to 85%

Life expectancy                    Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h)
                                   Electrical:

                                     H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
                                     H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h)

Impulse withstand voltage          Between power terminals:
                                   3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
                                   1 kV for 12 VDC, 24 VDC, 48 VDC

                                   Between exposed non-current-carrying metal parts:
                                   4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
                                   1.5 kV for 12 VDC, 24 VDC, 48 VDC

Noise immunity                     1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise)

Static immunity                    Destruction: 8 kV
                                   Malfunction: 4 kV

Enclosure rating                   IP40

Weight                             Approx. 50 g

EMC                                (EMI)                             EN61812-1

                                   Emission Enclosure:               EN55011 Group 1 class A

                                   Emission AC Mains:                EN55011 Group 1 class A

                                   (EMS)                             EN61812-1

                                   Immunity ESD:                     EN61000-4-2: 8 kV air discharge (level 3)

                                   Immunity RF-interference from AM Radio Waves:

                                                                     EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)

                                   Immunity Burst:                   EN61000-4-4: 2 kV power-line (level 3)

                                                                                  2 kV I/O signal-line (level 4)

                                   Immunity Surge:                   EN61000-4-5: 2 kV line to ground (level 3)

                                                                                  1 kV line to line (level 3)

Approved standards                 UL508, CSA C22.2 No. 14, Lloyds
                                   Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3Y-2/-2-0, 2.5 kV/1 for H3Y-4/-4-0)
                                   Output category according to EN60947-5-1.

Note: 1. Add 10 mS to the above value for the 0.5-S range model.
        2. Terminal screw sections are excluded.

                                                                                                                                       3
                                                                                                                                                               H3Y

Engineering Data

H3Y-2, H3Y-2-0                                 H3Y-2, H3Y-2-0

Switching operations (103)  250 VAC, cos = 1  Switching operations (103)  250 VAC, cos = 0.4
                             24 VDC, cos = 1                                24 VDC, L/R = 7 ms

                             Load current (A)                               Load current (A)

Reference: A maximum current of 0.6 A can be switched at 125 VDC (cos = 1).
                Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
                cases, a life of 100,000 operations can be expected.The minimum
                applicable load is 1 mA at 5 VDC (P reference value).

H3Y-4, H3Y-4-0                                                              H3Y-4, H3Y-4-0

Switching operations (103)  250 VAC, cos = 1  Switching operations (103)  250 VAC, cos = 0.4
                             24 VDC, cos = 1                                24 VDC, L/R = 7 ms

                             Load current (A)                               Load current (A)

Reference: A maximum current of 0.5 A can be switched at 125 VDC (cos = 1).
                Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
                cases, a life of 100,000 operations can be expected.The minimum
                applicable load is 1 mA at 1 VDC (P reference value).

Operation                                                                   H3Y-4, H3Y-4-0

Timing Chart

H3Y-2, H3Y-2-0

                                                                                                                                                           NC
                             NC

                                                                                                                                                                    4
                                                                                                                       H3Y

Dimensions                                                      H3Y-4

Note: All units are in millimeters unless otherwise indicated.

Timers

H3Y-2

                                             28 max.                                                     28 max.
                                         6.3                                                          6.3

                                   21.5                                                         21.5
                         6.4 max.                                                        6.4 max.

         (63.0)                                                          (63.0)

H3Y-2-0                                                         H3Y-4-0

             (60.7)                            28 max.                                                        28 max.

         Mounting Holes                    6.3                                                             6.3
                                 21.5                                                            21.5
                                 max.                                                            max.

                                                                               (60.7)

                                                                         Mounting Holes

                 Eight,                                                          Fourteen,
                 1.3-dia. holes                                                  1.3-dia. holes

                                                                                                                            5
                                                                                                                                                             H3Y

Accessories (Order Separately)

Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3Y. When ordering any one of these sockets, replace "@" with "08" or "14."

Track Mounting/Front Connecting Sockets
PYF08A

Two, 4.2 5            6            Eight, M3 8           3.4          Terminal Arrangement               Mounting Holes
mounting holes                       sems                                 (Top View)
                                                                                                                     Two, 4.5 dia.
                                                                                                                     M4 or M3

                                                                                                                                               H3Y

                                                                                                                                               Series

72 max.                                                           35.4                                                               90.5              86.6

                                                                                                                     590.3

                                                                       4                                                                       PYF@A
                                                                  6
                23 max.                          16.5                                                        150.2
                                                     30 max.       3.4
PYF14A
                                     Fourteen, M3 8
Two, 4.2 5                      6  sems                                          Terminal Arrangement      Mounting Holes
mounting holes                                                                     (Top View)
                                                                                                                   Two, 4.5 dia.
                                                                                                                   M4 or M3

72 max.                                                                   35.4

                                                                                                             590.3

                    29.5 max.                                                   4                                            220.2
                                                                          6

                                                    16.5
                                                        30 max.

PYF08A-N                                                                           Terminal Arrangement      Mounting Holes
                                                                                                             (for Surface Mounting)
                     22 max.

                                                                                   42     12

         4                    1                                                    4      1

         42                   12                                                   44     14

         8                    5                                                    8      5

         44                   14

                                                                                                                                     3.2 dia.

                                  66.5 max.                                                                          19.8            3.6 dia.

             PYF-08A-N

         41                   11                                                   12     9

         12                   9

                                                                                   41     11

         A2     A2            A1

                                                                                   14 14 13

         14     14            13

                                                                                   A2 A2 A1

                                                    30 max.

PYF14A-N

4           3       2      1                                                       Terminal Arrangement      Mounting Holes
                                                                                                             (for Surface Mounting)
42          32      22     12                                                                   42 32 22 12
                                                                                                4321                      Two, 3.5 dia.
8           7       6      5                                                                    44 34 24 14
                                                                                                8765                           20.8

44          34      24     14

                                  66.5 max.

         PYF-14A-N

41          31      21     11

12          11      10     9

A2          A2             A1                                                      12 11 10 9

14          14             13                                                      41 31 21 11

                                                    30 max.                        14 14      13

         29.5 max.                                                                 A2 A2 A1

                                                                                                                                                                  6
                                                                                                                             H3Y

PYF08A-E                                                                       (Top View)

      Two, 4.2 5                Eight, M3 8                                            Two, 4.5 dia.
      mounting holes              sems                                                     M4 or M3

                72 max.

                         23 max.

PYF14A-E                                        31 max.                        (Top View)  Two, 4.5 dia.
                                                                                           M4 or M3
   Two, 4.2 5                   Eight, M3 8
   mounting holes                 sems

     72 max.

                       29.5 max.

                                             31 max.

Back Connecting Sockets
PY08, PY14

Eight, 3 1.2 dia. holes                                Terminal Arrangement  Panel Cutout
only for PY08 (Fourteen,                                 (Bottom View)
3 1.2 dia. holes)                                                                             21.4+00.2

                             24 max.                                              25.8+00.2

                       0.3                   29.5                                                                       H3Y
                                             max.                                                            59.3 Series
                                       25.5
                                       max.                                                                PY@, PY@-02,
                                                                                                           PY@QN(2)
2.7               7.7             2.6

     20 max.                                             PY08       PY14

PY08QN, PY14QN                                           Terminal Arrangement
PY08QN(2), PY14QN(2)                                     (Bottom View)

2.7 25 max. *                 24 max.
                              22 max.
           (See
           note)

                                       29.5 max.

                         11

     41.5 m*a*x.                                         PY08QN     PY14QN
                                                         PY08QN(2)  PY14QN(2)
     (see note)

Note: With PY@QN(2), dimension * should read
         20 max. and dimension ** 36.5 max.

PY08-02, PY14-02                                         Terminal Arrangement
                                                         (Bottom View)
                              22 max.

                       0.3                   29.5
                                             max.
                                       25.5
                                       max.

2.7               4.3                  2

     16.5 max.

                                                         PY08-02    PY14-02

                                                                                                                                  7
                                                                                        H3Y

Socket Mounting Plates (t = 1.6)

                 Applicable socket     For mounting 1 socket   For mounting 18 sockets
PY08, PY14, PY08QN(2), PY14QN(2)    PYP-1                     PYP-18

Note: PYP-18 may be cut to any desired length.

PYP-1                                           PYP-18

       Two, 3.4-dia. holes

Relay Hold-down Clips                                   Y92H-3 for          Y92H-4 for
                                                        PYF@A Socket        PY@ Socket
                                                        (Set of Two Clips)

Mounting Track                                          End Plate

PFP-100N/PFP-50N (see note 1)                           PFP-M

               1000 (500) (See note 2)

Note: 1. Meets DIN EN50022
          2. This dimension applies to PFP-50N.

Spacer

PFP-S

                                                                                             8
Installation                                    H3Y-4, H3Y-4-0                         H3Y

Connection                                                     Connect the DC power supply to
                                                                terminals 13 and 14 according to
H3Y-2, H3Y-2-0                                                  the polarity marks.

                Connect the DC power supply to
                terminals 13 and 14 according
                to the polarity marks.

                                                                                                  9
                                                                                                                                          H3Y

Safety Precautions                                                                             Wiring

Refer to Safety Precautions for All Timers.                                                    The power supply for the H3Y must be protected with equipment
                                                                                               such as a breaker approved by VDE.
When selecting a control output, use the H3Y-2 for switching ON and
OFF the power and the H3Y-4 for switching ON and OFF the minute                                Basic insulation is ensured between the H3Y's operating circuit and
load.                                                                                          control output.

The operating voltage will increase when using the H3Y in any place                            Insulation requirement:  Overvoltage category II,
where the ambient temperature is more than 50C. Supply 90% to                                                          pollution degree 1 (H3Y-4/-4-0),
110% of the rated voltages (at 12 VDC: 95% to 110%) when                                                                pollution degree 2 (H3Y-2/-2-0)
operating at 45C or higher.                                                                                            (with a clearance of 1.5 mm and a
                                                                                                                        creepage distance of 2.5 mm at 240 VAC)
Do not leave the H3Y in time-up condition for a long period of time
(for example, more than one month in any place where the ambient                               Output terminals next to each other on the H3Y-4 or H3Y-4-0 must
temperature is high), otherwise the internal parts (aluminum                                   have the same polarity.
electrolytic capacitor) may become damaged. Therefore, the use of
the H3Y with a relay as shown in the following circuit diagram is
recommended to extend the service life of the H3Y.

                                                             Auxiliary relay such as MY Relay

Do not connect the H3Y as shown in the following circuit diagram on
the right hand side, otherwise the H3Y's internal contacts different
from each other in polarity may become short-circuited.

Correct          Incorrect

                            L2

         L1  L2  L1

Use the following safety circuit when building a self-holding or self-
resetting circuit with the H3Y and an auxiliary relay, such as an MY
Relay, in combination.

                                                                          : H3Y

                                                                           Auxiliary relay:
                                                                           MY Relay

Do not use the H3Y in places where there is excessive dust,
corrosive gas, or direct sunlight.
Do not mount more than one H3Y closely together, otherwise the
internal parts may become damaged. Make sure that there is a
space of 5 mm or more between any H3Y Models next to each other
to allow heat radiation.
The internal parts may become damaged if a supply voltage other
than the rated ones is imposed on the H3Y. When more than 100 V is
applied to 12- or 24-VDC models, the internal element (varistor) may
break.

Precautions for EN61812-1
Conformance

The H3Y as a built-in timer conforms to EN61812-1 provided that the
following conditions are satisfied.

Handling

Before dismounting the H3Y from the socket, make sure that no
voltage is imposed on any terminal of the H3Y.

                          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
                          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                            In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                                    10
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2008.11
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2008 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved