电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

H3RN-21-AC24

器件型号:H3RN-21-AC24
器件类别:热门应用    机电_工控_自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Timers TIMER SLIM-MULTI

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Timers
RoHS:YES
系列:
Series:
H3RN
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
H3RN21AC24
单位重量:
Unit Weight:
0.634931 oz

H3RN-21-AC24器件文档内容

    Solid-state timer

    H3RN

                                                                                                                       CSM_H3RN_DS_E_3_1

Ultra-slim Timer for G2R Relay Socket

• Pin configuration compatible with G2R Relay and mounts to the

P2R/P2RF Socket.

• Standard multiple time ranges and multiple operating modes.

• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt-

age, and EMC Directives.

                                                                                 For the most recent information on models that have been

                                                                                 certified for safety standards, refer to your OMRON website.

Model Number Structure

I Model Number Legend

H3RN-@@

            1  2

1.  Output                                                               2.  Time Range

    1:   SPDT                                                                None: Short-time range (0.1 s to 10 min)

    2:   DPST-NO                                                             1:  Long-time range (0.1 min to 10 hrs)

Ordering Information

I List of Models

         Supply voltage              Time-limit contact                  Short-time range model     Long-time range model

                                                                                 (0.1 s to 10 min)                     (0.1 min to 10 h)

24 VAC;                      SPDT                                H3RN-1                             H3RN-11

12, 24 VDC                   DPST-NO                             H3RN-2                             H3RN-21

Note:   Specify both the model number and supply voltage when ordering.

            Example: H3RN-1  24 VAC

                                     Supply voltage

I Accessories (Order Separately)

Connecting Socket

                  Timer               Track mounting/Front connecting socket                        Back connecting socket

H3RN-1/-11                            P2RF-05-E                                          P2R-057P

H3RN-2/-21                            P2RF-08-E                                          P2R-087P

                                                                                                                                               1
                                                                                                                                       H3RN

Specifications

I Ratings

                  Item                                        H3RN-1/H3RN-2                                        H3RN-11/H3RN-21

Time ranges                            0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max.            0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs max.

                                       selectable)                                                  selectable)

Rated supply voltage (See   note  2.)  24 VAC (50/60 Hz); 12, 24 VDC

Pin type                               Plug-in

Operating mode                         ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch

Operating voltage range                85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)

                                       (See note 1.)

Reset voltage                          10% max. of rated supply voltage

Power consumption                      24  VAC:        Relay  ON:  approx.  0.8  VA (0.6 W) at  24  VAC,  60  Hz

                                                       Relay  OFF: approx.  0.6  VA (0.4 W) at  24  VAC,  60  Hz

                                       12  VDC:        Relay  ON:  approx.  0.5  W at 12 VDC

                                                       Relay  OFF: approx.  0.2  W at 12 VDC

                                       24  VDC:        Relay  ON:  approx.  0.6  W at 24 VDC

                                                       Relay  OFF: approx.  0.3  W at 24 VDC

Control outputs                        3 A at 250 VAC, resistive load (cosφ = 1) (G6B-2@14P-FD-US used (Contact materials : AgSnIn))

                                       The minimum applicable load is 10 mA at 5 VDC (P reference value).

Note: 1.  When using the H3RN in any place where the ambient temperature is more than 50°C, supply 90% to 110% of the rated voltages

          (12 VDC: 95% to 110% of the rated voltage).

     2.   Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor.

I Characteristics

                  Item                                        H3RN-1/H3RN-2                                        H3RN-11/H3RN-21

Accuracy of operating time             ±1% FS max. (1 s range: ±1%±10 ms max.)

Setting error                          ±15%±50 ms FS max.

Reset time                             Min. power-opening time: 12, 24 VDC: 0.1 s max. (including halfway reset)

                                                                   24 VAC:       0.5 s max. (including halfway reset)

Influence of voltage                   ±2% FS max.

Influence of temperature               ±2% FS max.

Insulation resistance                  100 MΩ min. (at 500 VDC)

Dielectric strength                    2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different

                                       poles)

                                       1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance                   Destruction:    10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions

                                       Malfunction:    10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions

Shock resistance                       Destruction:    300 m/s2

                                       Malfunction:    100 m/s2

Ambient temperature                    Operating:      −10°C to 55°C (with no icing)

                                       Storage:        −25°C to 65°C (with no icing)

Ambient humidity                       Operating:      35% to 85%

Life expectancy                        Mechanical:     10,000,000 operations min. (under no load at 1,800 operations/h)

                                       Electrical:     100,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)

Impulse withstand voltage              Between power terminals: 1 kV

Noise immunity                         ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)

Static immunity                        Destruction:    8 kV

                                       Malfunction:    4 kV

Degree of protection                   IP40 (Terminal screw sections are excluded.)

Weight                                 Approx. 18 g

EMC                                    (EMI)                                                        EN61812-1

                                       Emission Enclosure:                                          EN55011 Group 1 class A

                                       Emission AC Mains:                                           EN55011 Group 1 class A

                                       (EMS)                                                        EN61812-1

                                       Immunity ESD:                                                IEC61000-4-2

                                       Immunity RF-interference:                                    IEC61000-4-3

                                       Immunity Burst:                                              IEC61000-4-4

                                       Immunity Surge:                                              IEC51000-4-5

                                       Immunity Conducted Disturbance:                              IEC61000-4-6

                                       Immunity Voltage Dip/Interruption:                           IEC61000-4-11

Approved standards                     UL508, CSA C22.2 No. 14

                                       Conforms to EN61812-1, IEC60664-1 4 kV/2.

                                       Output category according to IEC60947-5-1.

                                                                                                                                                         2
                                                                                                                                   H3RN

Connections

■ Connection

H3RN-1/H3RN-11                                                                  H3RN-2/H3RN-21

                                          DIN Indication                                                           DIN Indication

       Timer                                                                            Timer

       circuit                                                                          circuit

       OUT  PW                                                                          OUT  PW

       Bottom View                                                                      Bottom View

Pulse Operation

A pulse output for a certain period can be  obtained with a random external             input signal.

Use the H3RN in interval mode as shown      in the following timing charts.

H3RN-2/H3RN-21

                                                          Power (3-8)

                                                          External short circuit (1-4)

                                                                                                 50 ms

                                                          External input (1-3)                   min.

                                                          Time limit contact

                 Timer                                    NO (6-5)

                 circuit                                  Run/Power indicator (PW)

                                                          Output indicator (OUT)

                          External input                                                Note:    t:     Set time

                                                                                        Rt:      Reset time

!Caution

Be careful when connecting wires.

                 Mode                                                                                   Terminals

Pulse operation                             Power supply between 3 and 8

                                            Short-circuit between 4 and 1

                                            Input signal between 3 and 1

Operating mode; interval and all other      Power supply between 1 and 8

modes

                                                                                                                                         3
                                                                                                H3RN

Operation

■ Timing Chart

        Operating mode                                      Timing chart

                                            H3RN-1/H3RN-11                      H3RN-2/H3RN-21

ON-delay

                        Power (1-5)

Power                                                       Power (1-8)

                        Time limit contact

                        NC (4-2)                            Time limit contact

Output                  Time limit contact                  NO (4-3, 5-6)

                        NO (4-3)                            Run/Power

                        Run/Power                           indicator (PW)

                        indicator (PW)                      Output indicator

                        Output indicator                    (OUT)

                        (OUT)

Interval

                        Power (1-5)

Power                                                       Power (1-8)

                        Time limit contact

                        NC (4-2)                            Time limit contact

Output                  Time limit contact                  NO (4-3, 5-6)

                        NO (4-3)                            Run/Power

                        Run/Power                           indicator (PW)

                        indicator (PW)                      Output indicator

                        Output indicator                    (OUT)

                        (OUT)

Flicker OFF-start

                        Power (1-5)

Power                                                       Power (1-8)

                        Time limit contact

                        NC (4-2)                            Time limit contact

Output                  Time limit contact                  NO (4-3, 5-6)

                        NO (4-3)                            Run/Power

                        Run/Power                           indicator (PW)

                        indicator (PW)                      Output indicator

                        Output indicator                    (OUT)

                        (OUT)

Flicker ON-start

                        Power (1-5)

Power                                                       Power (1-8)

                        Time limit contact

                        NC (4-2)                            Time limit contact

Output                  Time limit contact                  NO (4-3, 5-6)

                        NO (4-3)                            Run/Power

                        Run/Power                           indicator (PW)

                        indicator (PW)                      Output indicator

                        Output indicator                    (OUT)

                        (OUT)

Note: t:  Set time

        Rt: Reset time

                                                                                                      4
                                                                                                                                       H3RN

■ DIP Switch Settings

The 1-s range and ON-delay mode for H3RN-1/-2, 1-min              range and  ON-delay mode for  H3RN-11/-21  are  factory-set  before  shipping.

Time Ranges

Model               Time range             Time setting           Setting       Factory-set

                                           range

H3RN-1,            1s               0.1 to 1 s                                  Yes

H3RN-2

                   10 s             1 to 10 s                                   No

                   1 min            0.1 to 1 min                                No

                   10 min           1 to 10 min                                 No

H3RN-11,           1 min            0.1 to 1 min                                Yes

H3RN-21

                   10 min           1 to 10 min                                 No

                   1h               0.1 to 1 h                                  No

                   10 h             1 to 10 h                                   No

Note: The left two  DIP switch pins are    used  to  select  the  time ranges.

Operating           Modes

                    Operating mode                                Setting       Factory-set

ON-delay                                                                        Yes

Interval                                                                        No

Flicker OFF-start                                                               No

Flicker ON-start                                                                No

Note: The right two DIP switch pins are used to select the operating modes.

Nomenclature

                         Run/Power Indicator (Green)

                         (Lit: Power ON)

                                                                                     Main Dial

                                                                                     Set the desired time according to time

                         Output Indicator (Orange)                                   range selectable by DIP switch.

                         (Lit: Output ON)

                                                                                                                                                  5
                                                                                                                                         H3RN

Dimensions

Note: All units are in millimeters unless otherwise  indicated.

■ Timers

H3RN-1/H3RN-11 Front Mounting

H3RN-2/H3RN-21 Front Mounting

Mounting Height

Use the P2RF-@-E or P2R-@7P to mount the H3RN. When ordering              any  one of these sockets,

replace "@" with "05" for SPDT or "08" for DPST-NO.

The P2RF-@ cannot be used because the hook is a different shape.

P2RF-@-E                                                                       P2R-@7P

                                                                                                      H3RN Series

                            H3RN Series

                                                     80.9 (see note 1)

P2RF-@-E                                             (84.9) (see note 2)

Socket

                                                     79.5 (see note 1)                                P2R-@7P

                                                     (83.5) (see note 2)                              Socket

                                                                                        Note:         There are no restrictions to  the

Note:   1.  The value shown indicates the dimension for the                                           mounting direction.

            P2RF-05-E with the PFP-@N Mounting Rail.

            The value is 71.5 mm when using the PFP-N@2.

        2.  The value shown in parentheses indicates the

            dimension for the P2RF-08-E with the PFP-@N

            Mounting Rail.

            The value is 75.5 mm when using the PFP-N@2.

                                                                                                                                               6
                                                                                                                                       H3RN

Safety Precautions

■ Correct Use                                                           Do not use the SPDT contact in a circuit which may cause short-cir-

                                                                        cuiting at three points (otherwise, short-circuiting of the power supply

When using the H3RN in any place where the ambient temperature          may occur) because the SPDT contact of H3RN-1/-11 is composed

is more than 50°C, supply 90% to 110% of the rated voltages (at         of an SPST-NC contact.

12 VDC: 95% to 110%).                                                                                       3

Do not leave the H3RN in time-up condition (i.e., with the internal                                                                 4

relay in an ON state) for a long period of time (for example, more                                   Short-circuit current

than one month in any place where the ambient temperature is high),                        Power supply

otherwise the internal parts may become damaged. Therefore, the                            for load

use of the H3RN with a relay as shown in the following circuit dia-                                         2

gram is recommended.

                                                                                                         1                  5

            X2/b           T/a     X1/a      X1/a                       Do not set to the minimum setting in the flicker modes, otherwise the

                                                                        contact may be damaged.

                                                                        Do not use the H3RN in places where there is excessive dust, corro-

         T             X1                X2                             sive gas, or direct sunlight.

                                   : Auxiliary relay such as G2R Relay  Make sure that there is a space of 3 mm or more between any H3RN

                                X                                       Models next to each other. (When using the P2RF-@-E Socket, a

The H3RN must be disconnected from the socket when setting the          space of 3 mm or more will be secured.) If a space of 3 mm or more

DIP switch, otherwise the user may touch a terminal imposed with a      is not secured, the ambient temperature must be less than 50°C.

high voltage and get an electric shock.                                 The internal parts may become damaged if a supply voltage other

Do not connect the H3RN as shown in the following circuit diagram       than the rated ones is imposed on the H3RN.

on the right hand side, otherwise the H3RN’s internal contacts differ-

ent from each other in polarity may become short-circuited.             ■ Precautions for EN61812-1

         Correct                             Incorrect                  Conformance

                                                             L2         The H3RN as a built-in timer conforms to EN61812-1 provided that

                                                                        the following conditions are satisfied.

                   L1      L2                      L1                   Handling

Use the following safety circuit when building a self-holding circuit   Do not touch the DIP switch while power is supplied to the H3RN.

with the H3RN and an auxiliary relay, such as a G2R Relay, in combi-    Before dismounting the H3RN from the socket, make sure that no

nation.                                                                 voltage is imposed on any terminal of the H3RN.

                                                                        Wiring

                                                                        Basic insulation is ensured between the H3RN’s operating circuit and

                                                                        control output.

                                                                        Basic insulation:            Overvoltage category III,

                                             G2R Relay                                               pollution degree 2

                                                                                                     (with a clearance of 3.0 mm and a creepage

In the case of the above circuit, the H3RN will be in pulse operation.                               distance of 3.0 mm at 240 VAC)

Therefore, if the circuit shown on page 3 is used, no auxiliary relay   The clearance from the edge of the P2R-087P Socket to internal,

will be required.                                                       current-carrying metal parts is 1.3 mm. Position the H3RN to provide

                                                                        the necessary clearance for the voltage used.

                                                                        When using the P2RF-@-E or P2R-057P Socket, basic insulation is

                                                                        ensured in the mounted condition for a voltage of 250 VAC max.

                       ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                       To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                   In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                  7
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2014.6

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

H3RN-11 AC24  H3RN-11 DC12  H3RN-11 DC24  H3RN-1 AC24  H3RN-21 AC24  H3RN-21 DC12  H3RN-21 DC24

H3RN-2 AC24  H3RN-2 DC12  H3RN-2 DC24  H3RN-1 DC24  H3RN-1 DC12

小广播

H3RN-21-AC24器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved