电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

H3M-H-DC125-B

器件型号:H3M-H-DC125-B
器件类别:热门应用    机电_工控_自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Timers TIMER

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Timers
RoHS:N
系列:
Series:
H3M
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
H3MHDC125B
单位重量:
Unit Weight:
3.527396 oz

H3M-H-DC125-B器件文档内容

   Solid-state Timer

   H3M

                                                                                                                               CSM_H3M_DS_E_2_2

Solid-state Timer with Variable Time Ranges

• Four time ranges are selectable per timer unit.

• Wide timing range of 0.05 second to 30 hours can be covered

by a combination of five timer units.

• Standard surface mounting type is easily convertible to flush

mounting type with the use of a special adapter (Y92F-40).

• Requires only 40 x 50 mm for mounting space.

• Equipped with power-ON & time-out indicators.

• All standard models approved by UL, CSA, and LR.

                                                                                  For the most recent information on models that have been certified for

                                                                                  safety standards, refer to your OMRON website.

Ordering Information

   Operation/resetting system         Time-limit contact       Instantaneous                                 Mounting

                                                                contact                Surface mounting                        Flush mounting

Time-limit operation/ self-resetting  DPDT                ---                     H3M                        H3M with Y92F-40 adapter

                                      SPDT                SPDT                    H3M-H                      H3M-H with Y92F-40 adapter

Note: 1.  Specify both the model number and supply voltage when ordering.

   2.     Sockets and adapters for surface/track mounting are available optionally and therefore, place the  order for them as necessary.

          Timer hold-down clips (F-hook and L-hook) are supplied with the timer.

■ Accessories (Order Separately)

Adapter

Y92F-40

Specifications

■ Time Ranges

Four time ranges are available for each timer by changing the time range selector switch positions to different combinations.

Time range code                                                  Time range selector switch

A                0.05 to 0.5 s                     0.5 to 5 s                     0.05 to 0.5 min            0.5 to 5 min

B                0.1 to 1 s                        1 to 10 s                      0.1 to 1 min               1 to 10 min

C                0.3 to 3 s                        3 to 30 s                      0.3 to 3 min               3 to 30 min

Time range code                                                  Time multiplying key

D                0.1 to 1 min                      1 to 10 min                    0.1 to 1 hrs               1 to 10 hrs

E                0.3 to 3 min                      3 to 30 min                    0.3 to 3 hrs               3 to 30 hrs

                                                                                                                                                          1
                                                                                                                                         H3M

■ Ratings

Rated supply voltage                       100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60      Hz),

                                           12, 24, 48, 100, 110 VDC (see note 2)

Operating voltage range                    AC:  85% to 110% of rated supply voltage

                                           DC: 80% to 110% of rated supply voltage (see note 3)

Power consumption                          AC:  Approx. 5 VA/2 W

                                           DC: Approx. 2 W

Control outputs                            5 A at 250 VAC, resistive load (cosφ = 1)

Note: 1.  Color indicators for the rated voltage are provided on the front of the Timer.

          Blue: 100/110/120 VAC

          Red: 200/220/240 VAC

          None: Other voltages

2.        With DC ratings, single-phase full-wave rectified power sources may be used.

3.        90% to 110% for 12-VDC models.

■ Characteristics

Accuracy of operating time                 ±1% max. (see note)

Setting error                              ±10% max.

Reset time                                 0.1 s max.

Influence of voltage                       ±1% max. (see note)

Influence of temperature                   ±2% max. (see note)

Insulation resistance                      100 MΩ min. (at 500 VDC)

Dielectric strength                        2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)

                                           1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit)

                                           1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance                       Destruction: 10 to 55 Hz with 0.75-mm double amplitude

                                           Malfunction: 10 to 55 Hz with 0.5-mm double amplitude

Shock resistance                           Destruction: 1,000 m/s2 (approx. 100G)

                                           Malfunction: 100 m/s2 (approx. 10G)

Ambient temperature                        Operating:   –10°C to 50°C

                                           Storage:     –25°C to 65°C

Ambient humidity                           Operating: 35% to 85%

Life expectancy                            Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)

                                           Electrical:  100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)

Approved standards                         UL (File No. E41515), CSA (File No. LR22310)

Weight                                     Approx. 100 g

Note: For the timer with time range  code  A, add ±10 ms to the respective characteristics when the time range selector switches are in  the x 1 s

(0.05 to 0.5 s) position.

                                                                                                                                                    2
                                                                                                                                                             H3M

Engineering Data

Switching operations (×103)                                             Reference:  A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1).

                                                                                    Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,

                                                                                    a life of 100,000 operations can be expected.The minimum applicable

                                                                                    load is 10 mA at 5 VDC (failure level: P).

                                          Load current (A)

Operation

■ Timing Chart

H3M                                                 Rt                              H3M-H

                                          Set time            Set time                                Set  time       Rt         Set   time

                             7-2 (Power)                                            2-7 (Power)

                             1-4 (NC)                                                      8-5 (NC)

                             1-3 (NO)                                                      8-6 (NO)

                             8-5 (NC)                                                      1-4 (NC)

                             8-6 (NO)                                                      1-3 (NO)

Power ON                                                                            Power ON

indicator lamp                                                                      indicator lamp

                             Time-out                                                      Time-out

                             indicator                                                     indicator

                                          Rt: Resetting time                                                     Rt:  Resetting  time

                                                                                                                                                                  3
                                                                                                                                             H3M

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H3M(-H)

■ Accessories (Order Separately)

Y92F-40 Adapter with Flush Mounting

                                     63.5

                                     75.5

Note:    When two or more timers mounted in line are to be continuously energized at the same time after the lapse

         of the set time, be sure to limit the carry current to less than 1 A. When using the timers at an ambient

         temperature of more than 40°C, be sure to reset the timers immediately after the set time has elapsed.

Track Mounted/Front Connecting Socket

PF085A                                                                                                              Mounting Height of

Eight, M3.5 × 7 sems                       Terminal Arrangement  Mounting Holes                                     Timer with Socket

                                           (Top View)

                      Two, 4.5 dia.                              Four, 5 dia. or M4 holes

                      holes

                                                                                           Note: There are no restrictions                   to

                                                                                                                    the mounting direction.

Hold-down Clips (Attached)

PHC-1 For PF085A

         F-hook

                                                                                                                                                  4
                                                                                                                       H3M

Back Connecting Socket

PL08                                                                                               Mounting Height of

                                                Terminal Arrangement  Mounting Holes               Timer with Socket

                                   Two, 2 dia.  (Bottom View)         Two, 3.5 dia. or M3

                                   holes                              socket mounting

                                                                      holes

P3G-08

                                                Terminal Arrangement                               Mounting Height of

                                                (Bottom View)                                      Timer with Socket

Mounting Track                                  End Plate                                  Spacer

PFP-100N/PFP-50N                                PFP-M                                      PFP-S

                  (See note)

Note:  This dimension applies  to  PFP-50N.

                                                                                                                            5
                                                                                                                                            H3M

Installation

■ Connection

H3M                                                                      H3M-H

Safety Precautions

Refer to Safety Precautions for All Timers.

Power Source Connection                                                         Connections

Because the AC-operated version is a capacitive load, the solid-state           Connecting the Operating Power Supply

relay to be used must be rated at a dielectric strength two times as            If using an AC power supply, connect it between terminals 2 and 7. If

that of the timer to switch the power source of the timer.                      using a DC power supply, connect the positive line to terminal 7 and

The H3M contains a capacitor-drop power circuit. Use a sinusoidal               the negative line to terminal 2. An AC power supply can be

power supply with a commercial frequency. Do not use power                      connected without considering polarity, but the DC power supply

supplies with a high frequency component (such as inverter power                lines must be connected as specified.

supplies) for Timers with 100 to 240-VAC specifications. Using these            Other Precautions

power supplies can damage internal circuits.

How to Change the Time Range                                                    • A DC power supply must have 50% or less ripple and the average

                                                                                voltage must be within the rated supply voltage specification.

The H3M is provided with two time range selector switches. One is               • A P3G-08 Socket can be used instead of a US-08 Socket to reduce

on the lower right side A of the front panel and the other on the lower         the depth. Also, the P3G-08 has screw terminals, making

left side. Change the positional combination of the time range                  maintenance easier.

selector switches with a flat-blade screwdriver as desired.

                                                                                                     US-08                                  P3G-08

                                              A

                !CAUTION

Be sure to turn the power off before changing the time specification.

Changing the time range while the timer is in operation may result in

a malfunction.

                ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                       6
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)

from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.                     ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.                                OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS

IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products.   This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given.             This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

   safety equipment, and installations subject to separate industry or government regulations.

  Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the products may be changed without any notice.     When in doubt, special model numbers may be assigned to fix or

establish key specifications for your application on your request.  Please consult with your OMRON representative at any time to confirm actual

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent               the

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

                                                                                                                                                                         2012.8

                                                      In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                                  (c)Copyright OMRON Corporation 2012 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

H3M-AC120-A      H3M-AC120-B  H3M-AC120-C   H3M-AC120-D   H3M-AC120-E   H3M-AC200/220/240-A    H3M-

AC200/220/240-D  H3M-AC220-B   H3M-AC240-C  H3M-AC24-B    H3M-DC24-A    H3M-DC24-B  H3M-DC24-C  H3M-

DC24-D  H3M-H-AC100/110/120-A  H3M-H-AC100/110/120-C     H3M-H-AC120-B  H3M-H AC200/220/240 C   H3M-H-

AC200/240-D  H3M-H DC125 B    H3M-H DC12 B  H3M-H-DC12-C  H3M-US-DC12-B  H3M DC48 A  H3M DC48 C

H3M DC110 B

小广播

H3M-H-DC125-B器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved