timers timer

参数

Manufacturer: Omron
Product Category: Timers
RoHS: No
Brand: Omron Automation and Safety
Series: H3M
Factory Pack Quantity: 1

H3M-AC200/220/240-D器件文档内容

Solid-state Timer                                                                                         CSM_H3M_DS_E_2_1

H3M

Solid-state Timer with Variable Time Ranges

Four time ranges are selectable per timer unit.
Wide timing range of 0.05 second to 30 hours can be covered

by a combination of five timer units.
Standard surface mounting type is easily convertible to flush

mounting type with the use of a special adapter (Y92F-40).
Requires only 40 x 50 mm for mounting space.
Equipped with power-ON & time-out indicators.
All standard models approved by UL, CSA, and LR.

Ordering Information

    Operation/resetting system        Time-limit contact Instantaneous                   Surface mounting  Mounting
Time-limit operation/ self-resetting                                      contact  H3M                                    Flush mounting
                                                                                   H3M-H
                                      DPDT  ---                                                                H3M with Y92F-40 adapter
                                      SPDT  SPDT                                                               H3M-H with Y92F-40 adapter

Note: 1. Specify both the model number and supply voltage when ordering.
        2. Sockets and adapters for surface/track mounting are available optionally and therefore, place the order for them as necessary.
            Timer hold-down clips (F-hook and L-hook) are supplied with the timer.

Accessories (Order Separately)

Adapter

Y92F-40

Specifications

Time Ranges

Four time ranges are available for each timer by changing the time range selector switch positions to different combinations.

Time range code                                          Time range selector switch

A                0.05 to 0.5 s              0.5 to 5 s                          0.05 to 0.5 min            0.5 to 5 min
                                            1 to 10 s                           0.1 to 1 min               1 to 10 min
B                0.1 to 1 s                 3 to 30 s                           0.3 to 3 min               3 to 30 min

C                0.3 to 3 s                                      Time multiplying key

Time range code

D                0.1 to 1 min               1 to 10 min                            0.1 to 1 hrs            1 to 10 hrs

E                0.3 to 3 min               3 to 30 min                            0.3 to 3 hrs            3 to 30 hrs

                                                                                                                                           1
                                                                                                                        H3M

Ratings

Rated supply voltage        100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz),
Operating voltage range     12, 24, 48, 100, 110 VDC (see note 2)
Power consumption
Control outputs             AC: 85% to 110% of rated supply voltage
                            DC: 80% to 110% of rated supply voltage (see note 3)

                            AC: Approx. 5 VA/2 W
                            DC: Approx. 2 W

                            5 A at 250 VAC, resistive load (cos = 1)

Note: 1. Color indicators for the rated voltage are provided on the front of the Timer.
            Blue: 100/110/120 VAC
            Red: 200/220/240 VAC
            None: Other voltages

        2. With DC ratings, single-phase full-wave rectified power sources may be used.

        3. 90% to 110% for 12-VDC models.

Characteristics

Accuracy of operating time  1% max. (see note)
Setting error               10% max.
Reset time                  0.1 s max.
Influence of voltage
Influence of temperature    1% max. (see note)
Insulation resistance       2% max. (see note)
Dielectric strength         100 M min. (at 500 VDC)
                            2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
Vibration resistance        1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit)
                            1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Shock resistance
                            Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Ambient temperature         Malfunction: 10 to 55 Hz with 0.5-mm double amplitude

Ambient humidity            Destruction: 1,000 m/s2 (approx. 100G)
Life expectancy             Malfunction: 100 m/s2 (approx. 10G)

Approved standards          Operating: 10C to 50C
Weight                      Storage: 25C to 65C
                            Operating: 35% to 85%

                            Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
                            Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)

                            UL (File No. E41515), CSA (File No. LR22310)

                            Approx. 100 g

Note: For the timer with time range code A, add 10 ms to the respective characteristics when the time range selector switches are in the x 1 s
        (0.05 to 0.5 s) position.

                                                                                                                                                 2
                                                                                          H3M

Engineering Data

Switching operations (103)                                             Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos = 1).
                                                                                        Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
                                                                                        a life of 100,000 operations can be expected.The minimum applicable
                                                                                        load is 10 mA at 5 VDC (failure level: P).

                                          Load current (A)

Operation

Timing Chart

H3M                                                 Rt                  H3M-H                              Rt Set time

                                          Set time            Set time             2-7 (Power)   Set time

                             7-2 (Power)                                               8-5 (NC)
                                1-4 (NC)
                                                                                       8-6 (NO)
                             1-3 (NO)
                             8-5 (NC)                                                  1-4 (NC)
                                                                                       1-3 (NO)
      8-6 (NO)                                                                     Power ON
  Power ON                                                                      indicator lamp
indicator lamp                                                                        Time-out
                                                                                      indicator
     Time-out
     indicator

                                          Rt: Resetting time                                               Rt: Resetting time

                                                                                                                                                                 3
                                                                                                                    H3M

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H3M(-H)

Accessories (Order Separately)

Y92F-40 Adapter with Flush Mounting

                                                          63.5
                                                          75.5

Note: When two or more timers mounted in line are to be continuously energized at the same time after the lapse
         of the set time, be sure to limit the carry current to less than 1 A. When using the timers at an ambient
         temperature of more than 40C, be sure to reset the timers immediately after the set time has elapsed.

Track Mounted/Front Connecting Socket

PF085A                                                                                    Mounting Height of
                                                                                          Timer with Socket
Eight, M3.5 7 sems                 Terminal Arrangement       Mounting Holes
                                     (Top View)

                      Two, 4.5 dia.                             Four, 5 dia. or M4 holes
                      holes

                                                                                          Note: PF085A can be used as a
                                                                                                   front connecting socket.

Hold-down Clips (Attached)

         PHC-1 For PF085A

                        F-hook

                                                                                                                             4
Back Connecting Socket                                                                                           H3M
PL08
                                                                                                    Mounting Height of
                        Two, 2 dia.              Terminal Arrangement      Mounting Holes           Timer with Socket
                        holes                    (Bottom View)
                                                                       Two, 3.5 dia. or M3
                                                                       socket mounting
                                                                       holes

P3G-08

                                                 Terminal Arrangement                               Mounting Height of
                                                 (Bottom View)                                      Timer with Socket

Mounting Track                                   End Plate                                  Spacer

PFP-100N/PFP-50N                                 PFP-M                                      PFP-S

                                     (See note)

Note: This dimension applies to PFP-50N.

                                                                                                                        5
                                                                                       H3M

Installation

Connection                                                              H3M-H

H3M

Safety Precautions                                                       Connections

Refer to Safety Precautions for All Timers.                              Connecting the Operating Power Supply
                                                                         If using an AC power supply, connect it between terminals 2 and 7. If
Power Source Connection                                                  using a DC power supply, connect the positive line to terminal 7 and
                                                                         the negative line to terminal 2. An AC power supply can be
Because the AC-operated version is a capacitive load, the solid-state    connected without considering polarity, but the DC power supply
relay to be used must be rated at a dielectric strength two times as     lines must be connected as specified.
that of the timer to switch the power source of the timer.
The H3M contains a capacitor-drop power circuit. Use a sinusoidal        Other Precautions
power supply with a commercial frequency. Do not use power
supplies with a high frequency component (such as inverter power          A DC power supply must have 50% or less ripple and the average
supplies) for Timers with 100 to 240-VAC specifications. Using these       voltage must be within the rated supply voltage specification.
power supplies can damage internal circuits.
                                                                         A P3G-08 Socket can be used instead of a US-08 Socket to reduce
How to Change the Time Range                                               the depth. Also, the P3G-08 has screw terminals, making
                                                                           maintenance easier.
The H3M is provided with two time range selector switches. One is
on the lower right side A of the front panel and the other on the lower
left side. Change the positional combination of the time range
selector switches with a flat-blade screwdriver as desired.

                                                                                US-08  P3G-08

                                                        A

                            !CAUTION

Be sure to turn the power off before changing the time specification.
Changing the time range while the timer is in operation may result in
a malfunction.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                         6
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2008.11
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2008 All Right Reserved.
http://www.ia.omron.com/
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

  H3M-AC120-A H3M-AC120-B H3M-AC120-C H3M-AC120-D H3M-AC120-E H3M-AC200/220/240-A H3M-
AC200/220/240-D H3M-AC220-B H3M-AC240-C H3M-AC24-B H3M-DC24-A H3M-DC24-B H3M-DC24-C H3M-
DC24-D H3M-H-AC100/110/120-A H3M-H-AC100/110/120-C H3M-H-AC120-B H3M-H AC200/220/240 C H3M-H-
AC200/240-D H3M-H DC125 B H3M-H DC12 B H3M-H-DC12-C H3M-US-DC12-B Y92F-40 US-08 H3M DC48 A
H3M DC48 C

小广播

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved