    Solid-state Timer

    H3FA

                                                                                                                             CSM_H3FA_DS_E_3_1

Please read and understand this catalog before purchasing the products.  Please  consult  OMRON   representative   if  you  have any questions or

comments. Refer to Safety Precautions on page 9.

DIP Model Timer for PC Board Use Provides

Contact and Solid-state Output

• Four time ranges are selectable.

Models suffixed -@A@: 1 s, 10 s, 1 min, 10 min.

Models suffixed -@B@: 6 s, 60 s, 6 min, 60 min.

• Timer operation may also be controlled through an external

variable resistor.

• Timer can be cleaned while mounted on a PC Board with the

sealing tape affixed.

• Twenty-four-pin IC socket can be used for mounting the Timer.

• Mountable on a 1-inch pitch rack.

(H 19.5 × W 36.9 × D 17.75 mm)

Model Number Structure

Note: This model number legend includes combinations that are not  available.  Before ordering, please check  the  List  of  Models  on  page  2  for

        availability.

H3FA- @ @ @ @

        1       2      3  4

1.  Time-limit contact                                                   4.    Supply voltage

    None: Contact outputs (SPST-NO + SPST-NC)                                  For contact output models

    S:  Solid-state outputs                                                    5DC:       5 V DC

2.  Time range                                                                 6DC:       6 V DC

    A:  1 s to 10 min                                                          12DC:      12 V DC

    B:  6 s to 60 min                                                          24DC:      24 V DC

3.  Operation/resetting system                                                 For solid-state output models

    None: Time-limit operation/power-OFF resetting and external                5/6DC:     5/6 V DC

        resetting, Integrating operation/power-OFF resetting and               12/24DC:   12/24 V DC

        external resetting

    U:  Instantaneous operation, time-limit resetting/external

        resetting

                                                                                                                                                       1
                                                                                                                                            H3FA

Ordering Information

■ List of Models

Item           Model        H3FA-A         H3FA-B     H3FA-SA            H3FA-SB   H3FA-AU         H3FA-BU         H3FA-SAU            H3FA-SBU

Operation/resetting   Time-limit operation/power-OFF resetting and external        Instantaneous operation, time-limit resetting/external

system (See note.)    resetting,                                                   resetting

                      Integration operation/power-OFF resetting and external

                      resetting

Time-limit contact    Contact output                 Solid-state output            Contact output                  Solid-state output

                      (SPST-NO + SPST-NC)                                          (SPST-NO + SPST-NC)

Instantaneous         ---

contact

Mounting method       Surface mounting (with IC socket or direct mounting on PC    Board)

Time range            1 s to 10 min   6 s to 60 min  1 s to 10 min  6 s to 60 min  1 s to 10 min   6 s to 60 min   1 s to 10 min       6 s to 60 min

Supply    5 V DC      H3FA-A 5DC      H3FA-B 5DC     ---            ---            H3FA-AU         H3FA-BU         ---                 ---

voltage                                                                            5DC             5DC

          6 V DC      H3FA-A 6DC      H3FA-B 6DC     ---            ---            H3FA-AU         ---             ---                 ---

                                                                                   6DC

          12 V DC     H3FA-A          H3FA-B         ---            ---            H3FA-AU         H3FA-BU         ---                 ---

                      12DC            12DC                                         12DC            12DC

          24 V DC     H3FA-A          H3FA-B         ---            ---            H3FA-AU         H3FA-BU         ---                 ---

                      24DC            24DC                                         24DC            24DC

          5/6 V DC    ---             ---            H3FA-SA        H3FA-SB        ---             ---             H3FA-SAU            H3FA-SBU

                                                     5/6DC          5/6DC                                          5/6DC               5/6DC

          12/24 V DC  ---             ---            H3FA-SA        H3FA-SB        ---             ---             H3FA-SAU            H3FA-SBU

                                                     12/24DC        12/24DC                                        12/24DC             12/24DC

Note: The desired operation/resetting system is selected by short-circuiting and opening the specified terminals.

Specifications

■ Time Ranges

                     Model                                    Rated time                                           Time setting range

H3FA-A                                        1s                                                 0.1 to 1 s

H3FA-AU                                       10 s                                               1 to 10 s

H3FA-SA                                       1 min                                              0.1 to 1 min

H3FA-SAU                                      10 min                                             1 to 10 min

H3FA-B                                        6s                                                 0.6 to 6 s

H3FA-BU                                       60 s                                               6 to 60 s

H3FA-SB                                       6 min                                              0.6 to 6 min

H3FA-SBU                                      60 min                                             6 to 60 min

Note: 1.  The above timing ranges apply when the internal variable resistor of H3FA is used.

2.        The external variable resistor may also be used by opening the terminal connected to   the internal variable resistor.

3.        Wire the appropriate terminal to select a time setting range. Refer to Rated Time and  Terminal Connections on page 4 for    details.

                                                                                                                                                      2
                                                                                                                                                                   H3FA

■ Ratings

                                        Item                                       H3FA-A/ H3FA-B                                          H3FA-SA/ H3FA-SB

                                                                             H3FA-AU/ H3FA-BU                                          H3FA-SAU/ H3FA-SBU

Rated supply voltage                                      5 V DC, 6V DC, 12V DC, 24 V DC (See note 1.)              5/6 V DC (See note 1.)

                                                                                                                    12/24 V DC (See notes 1 and 2.)

Operating voltage range                                   5 V DC:            90% to 110% of rated supply voltage    5/6 V DC:              90% to 110% of rated supply  voltage

                                                          6, 12, 24 V DC: 85% to 110% of rated supply voltage       12/24 V DC:            85% to 110% of rated supply  voltage

Power consumption                                         5, 6 V DC:         approx. 230 mW                         5/6 V DC:              approx. 80 mW

                                                          12 V DC:           approx. 270 mW                         12 V DC:               approx. 100 mW

                                                          24 V DC:           approx. 330 mW                         24 V DC:               approx. 240 mW

Control outputs                                           Contact output: SPST-NO + SPST-NC,                        Solid-state output: 150 mA max. at 30 V DC

                                                          3 A at 250 V AC with resistive load,                      Residual voltage:      1.0 V max.

                                                          Minimum applied load: 10 mA at 5 V DC

                                                          (Failure level: P, reference value)

Ambient temperature                                       Operating:         −10°C to 55°C (with no icing)

                                                          Storage:           −25°C to 65°C (with no icing)

Ambient humidity                                          35% to 85%

Note: 1.                         Permissible ripple:      20% max. (3% max. at 5, 6 V DC-operated models)

                                 Where,

                                 Mean                                     X  X/Mean value × 100 ≤ 20 (%) max.

                             2.  Supply voltage can be selected by short-circuiting (12 V DC) or opening (24 V DC) the specified terminals.

■ Characteristics

Accuracy of operating time                                   ±0.5% FS max. (See note 1.)

Setting error                                                0 to 30 % FS max. (at 20°C , at rated voltage)

Reset time                                                   10 ms max.

Influence of voltage                                         ±1% FS max. (2% FS max. for 5, 6, 5/6 V DC-operated models)

Influence of temperature                                     ±5% FS max. (See note 1.)

Insulation resistance                                        100 MΩ min. (at 500 V DC)

Dielectric strength                                          1,500 V AC, 50/60 Hz for 1 min (between control output and operating circuit) (See note 2.)

                                                             1,000 V AC, 50/60 Hz for 1 min (between contacts not located next to each other) (See note       2.)

Vibration resistance                                         Destruction: 10 to 55 Hz with 0.375-mm single amplitude in 3 directions for 1 hour each

                                                             Malfunction: 10 to 55 Hz with 0.25-mm single amplitude in 3 directions for 10 minutes each

Shock resistance                                             Destruction: 1,000 m/s2 3 times each in 6 directions

                                                             Malfunction: 100 m/s2 3 times each in 6 directions

Life expectancy                                              Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)

                                                             Electrical:     100,000 operations min. (3 A at 250 V AC, resistive load at 1,800 operations/h)

Approved safety standards                                    UL508, CSA C22.2 No.14

Weight                                                       Contact output models:     approx. 15 g

                                                             Solid-state output models: approx. 10 g

Note: 1.                         Add or subtract 10 ms to the ratings when using a timer with a rated time of 1 s.

                             2.  Applicable to contact output models.

■ Life-test Curve (Reference Values)

Switching operations (x104)  1,000

                             700

                             500

                             300

                             100

                                 70              24 VDC   L/R=7 ms

                                 50

                                 30                                 24 VDC cosφ=1

                                 10

                                 7      250 VAC cosφ=0.4     250 VAC cosφ=1

                                 5

                                     0        1           2         3              4

                                                                    Load current (A)

                                                                                                                                                                                 3
                                                                                                                                                                                                                                                                                                                                                                                                                              H3FA

Connections

■ Block Diagrams

Note: All diagrams are views from the top.

H3FA-A, H3FA-B, H3FA-SA, H3FA-SB

When the input voltage is applied, the CR oscillator circuit in the                                                                                                                  The voltage across the H3FA-SA and -SB (solid-state output loads)

Timer starts to oscillate via the power supply circuit, the counter                                                                                                                  is the load input voltage minus the residual voltage when the

circuit counts up to the preset setting, and an output signal is                                                                                                                     transistor turns ON.

produced. A transistor amplifies this signal to drive the load.

Contact Output                                                                                                                                                                       Solid-state                                                 Output

                                                                                          For the external resistor                         Contact output (NO contact for                                                                                                                                             For the external resistor                                                                     Short for 12 V DC

                                                                                          For the internal variable                                  time-limit operation)                                                                                                                                             For the internal variable                                                                     Open for 24 V DC (See note.)

                                                                                          resistor                                                                                                                                                                                                                     resistor

Power       Power supply  circuit  Voltage stabili-  zer circuit  CR oscillator  circuit  Counter circuit  Output amplifier  circuit                                              Power                 Power supply  circuit                    Voltage stabili-  zer circuit                 CR oscillator  circuit                   Counter circuit                    Output amplifier  circuit

supply                                                                                                                                                                            supply

                                                                                          Reset circuit                                                                                                                                                                                                       Reset circuit

                                                                                 Reset input                                                                                                                                                                                                                  Reset input                                                                                                  Load

                                   Time range                                                                                               Contact output (NC contact for                                            Time range selector

                                   selector                                                                                                          time-limit operation)

                                                                                                                                                                                                                                                                                                                                        5 to 24 V DC

                                                                                                                                                                                                                                                 10: Solid-state output terminal

                                                                                                                                                                                                                                                 12: Terminal for the internal load surge absorbing diode

                                                                                                                                                                                                                                                 Note:                                         When using 12/24 V DC-operated models.

H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU

Contact Output                                                                                                                                                                    Solid-state                                  Output

                                                                                          For the external resistor                                                                                                                                                                                           For the external resistor                                                                              Short for 12 V DC

                                                                                          For the internal variable resistor                                                                                                                                                                                  For the internal variable resistor                                                                     Open for 24 V DC (See note.)

Power       Power supply  circuit  Voltage stabili-  zer circuit  CR oscillator  circuit  Counter circuit  Output amplifier  circuit                                              Power   Power supply  circuit                Voltage stabili-  zer circuit                    CR oscillator  circuit                 Counter circuit                   Output amplifier  circuit

supply                                                                                                                                                                            supply

                                                                                                                                                                                                                                                                                                                                                                                                                        150 mA max.

                                                                                                                                                                                                                                                                                                                                                                                                                        Load surge-

                                                                                                                                                                                                                                                                                                                                                                                                                        absorbing diode

                                                                                 Reset circuit                                        Start circuit                                                                                                                                            Reset circuit                                                                                          Start circuit

                                                                                                                                                                                                                                                                                                                                                                                                                        Load

                                                                                                                                                                                                                                                                                                                          5 to 24 V DC

                                                                                                                                                                                                                                                 Note:                                         When using a 12/24                                                                                     V       DC-operated model.

■ Rated                            Time                                                   and              Terminal                                  Connections

            Model                                                                                                                                                                 Terminal connection

                                                                                                                             1        2  3                                  1  2  3                                                                                             1              2                       3                                                                                             1  2  3

H3FA-A/-SA/-AU/-SAU                                               1s                                                                                 10 s                                 1 min                                                                                                                                                                                                       10 min

H3FA-B/-SB/-BU/-SBU                                               6s                                                                                 60 s                                 6 min                                                                                                                                                                                                       60 min

Note: 1.    Short-circuit terminals 21 and 22 when using the internal variable resistor of H3FA.

        2.  An external resistor can also be used by opening terminals 21 and 22. When using an external resistor (1 MΩ for H3FA-A/-SA, 3 MΩ for H3FA-B/

            -SB), connect it between terminals 21 and 23.

                                                                                                                                                                                                                                                                                                                                                                                                                                                   4
                                                                                                                                                         H3FA

Operation

■ Timing Charts and External Connections

Note: Do not apply voltage to any terminals other than the power supply terminals. Otherwise, the internal circuits may be damaged.

H3FA-A, H3FA-B, H3FA-SA, H3FA-SB

Standard Operation (ON-delay operation)                                  Integration Operation

When the power is turned ON and the set time has elapsed, an             By opening the terminals connected to the internal variable resistor,

output is produced. (Power turns ON when power terminals 1 and 24        Timer operation can be interrupted to enable the Timer to perform

are shorted or when terminals 13 and 15 are shorted when using a         time integration operations. Interrupt Timer operation by opening

12/24 V DC-operated model with a 12 V DC power supply.)                  terminals 21 and 22 when using the internal variable resistor or

When connecting an external resistor to the Timer, connect it            terminals 21 and 23 when using the external resistor. Timer

between terminals 21 and 23, and open terminals 21 and 22. Refer         operation can be resumed by reconnecting the terminals.

to External Resistors and Operating Time (Reference Value) on page

7. When operating with an external reset input, short terminals 1 and

4. The Timer will start operating even if reset terminals 1 and 4 are

open when the power is turned ON.

In this case, the current flow is approximately 0.1 mA. If a contact is

used for control, use a contact with high contact reliability, If a                                                ON                                    OFF ON

transistor is used for control, use an ICEO of 10 μA and a VCE (sat) of  Power supply (terminals 1 and 24)

0.5 V or less.                                                           (See note.)

                        ON         OFF       ON            OFF                     For internal variable resistor  Short  Open      Short      Open      Short

Power supply                                                                       (terminals 21 and 22)

(terminals 1 and 24)                                                                  For external resistor

(See note.)             10 ms                Short         Short                      (terminals 21 and 23)                     10 ms

                        min.                                                                                                    min.

Reset input                                         Open                              Reset input

(terminals 1 and 4)                                                                   (terminals 1 and 4)

SPST-NO contact output                                                                SPST-NO contact output

(terminals 13 and 16)                                                                 (terminals 13 and 16)

Solid-state output                                                                    Solid-state output           T1           T2         T3        T4          Tn

(terminals 1 and 10)    Set time   Set time      Set time  Set time                   (terminals 1 and 10)

SPST-NC contact output                                                                SPST-NC contact output

(terminals 9 and 12)                                                                  (terminals 9 and 12)

Note: When using a 12/24 V DC-operated model with a 12 V DC              Note: 1.  Control output is provided when the set time has elapsed

power supply, short terminals 13 and 15.                                           (T1 + T2 or T3 + T4).

                                                                         2.        When using a 12/24 V DC-operated model with a 12 V DC

                                                                                   power supply, short terminals 13 and 15.

Contact Output (Top View)                                                Contact Output (Top View)

Solid-state Output (Top View)                                            Solid-state Output (Top View)

When using the 12/24 V DC-operated model with a 24 V DC power            When using the 12/24 V DC-operated model with a 24 V DC power

supply, open terminals 13 and 15.                                        supply, open terminals 13 and 15.

                                                                                                                                                                     5
                                                                                                                                                               H3FA

H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU

One-shot Output Operation                                                                   OFF-delay Operation

Turn ON the power and apply a start input (short terminals 6 and 1).                        Turn ON the power and apply a start input (short terminals 6 and 1).

(Power turns ON when power terminals 1 and 24 are shorted or                                (Power turns ON when power terminals 1 and 24 are shorted or

when terminals 13 and 15 are shorted when using a 12/24 V DC-                               when terminals 13 and 15 are shorted when using a 12/24 V DC-

operated model with a 12 V DC power supply.) An output is produced                          operated model with a 12 V DC power supply.) An output is produced

immediately and is reset when the set time has elapsed.                                     immediately. If the start input is applied constantly, however, the reset

If the reset input is applied (short terminals 4 and 1) with no start                       input can be applied until the set time elapses to stop time-limit

input (open terminals 6 and 1) while the Timer is operating, the Timer                      operation. (An output is produced when the start input is applied

stops operating and the output is reset.                                                    even when the constant reset input is ON prior to the start input.)

When operating with an external start or reset input, the current flow                      The time-limit operation starts when the reset input terminals are

from terminal 6 to terminal 1 (start input) or from terminal 4 to                           opened, and the output is reset when the set time has elapsed.

terminal 1 (reset input) is approximately 0.1 mA. A highly reliable                         When operating with an external start or reset input, the current flow

contact is therefore recommended for the start and reset inputs.                            is approximately 0.1 mA. A highly reliable contact is therefore

Use an ICEO of 10 μA and a VCE (sat) of 0.5 V or less for transistor                        recommended for the start and reset inputs. Use an ICEO of 10 μA

control. When connecting an external resistor to the Timer, connect it                      and a VCE (sat) of 0.5 V or less for transistor control.

between terminals 21 and 23, and open terminals 21 and 22.

Power supply            ON                                                                  Power supply            ON

(terminals 1 and 24)                                                                        (terminals 1 and 24)

(See note 1.)                                                                               (See note 1.)

                                   Short     Open                                    10 ms

Start input                                                                          min.

(terminals 1 and 6)                                                                         Start input

                                                                    (See                    (terminals 1 and 6)

                                                                    note 2.)         10 ms                                     Short     Open

Reset input                                                                          min.   Reset input

(terminals 1 and 4)                                                                         (terminals 1 and 4)

SPST-NO contact output                                                                      SPST-NO contact output

(terminals 13 and 16)                                                                       (terminals 13 and 16)

Solid-state output          T      T                                T                       Solid-state output

(terminals 1 and 10)                                                             t1         (terminals 1 and 10)        T      t1     T        t2     T        t3

SPST-NC contact output                                                                      SPST-NC contact output

(terminals 9 and 12)                                                                        (terminals 9 and 12)

Note: 1.     When using a 12/24 V DC-operated model with                      a  12 V DC    Note: 1.     When using a   12/24 V DC-operated model        with  a 12  V  DC

             power supply, short terminals 13 and 15.                                                    power supply,  short terminals 13 and 15.

2.           The start input is disabled during the time limit.                             2.           T denotes the  set time. t1, t2, and t3 < T

3.           T denotes the set time. t1 < T

Contact Output (Top view)                                                                   Contact Output (Top view)

                                             Contact output

                                             (SPST-NC contact for

                                             time-limit operation)

Solid-state Output (Top View)                                                               Solid-state Output (Top View)

When using the 12/24 V DC-operated model with a 24 V DC power                               When using the 12/24 V DC-operated model with a 24 V DC power

supply, open terminals 13 and 15.                                                           supply, open terminals 13 and 15.

                                                                                                                                                                            6
                                                                                                                                                       H3FA

■ External Resistors and Operating Time (Reference Value)

Refer to the following characteristics diagrams  H3FA-A/-SA/-AU/-SAU                                       H3FA-B/-SB/-BU/-SBU

when using an external resistor.                                                                           Operating time (%)

                                                 Operating time (%)  120                                                       120

•  Use an external resistor rated at about

   0.1 W/1 MΩ for H3FA-A, -SA, -AU, and -SAU                         100                                                       100

   or 0.1 W/3 MΩ for H3FA-B, -SB, -BU, and -

   SBU.

•  Do not run leads parallel to power lines and                      80                                                        80

   keep the leads shorter than 2 m to minimize

   the effects of external noise.                                    60                                                        60

•  The characteristics diagrams represent

   typical data. The factory set operating time

   may not always be uniform from one product                        40                                                        40

   to another. A variable resistor is

   recommended if more precise time                                  20                                                        20

   adjustments are required. The operating time

   is slightly longer than the set time as the

   length of the lead increases.                                     0    0.5  1             1.5                                   0  1             2  3     4

                                                                               External resistor (MΩ)                                                  External resistor (MΩ)

■ Extending the Reset Time

DIP Timers have a shorter reset time than that of conventional timers                   Rated voltage                                    Capacitor capacity

for use in solid-state circuit applications. To extend the reset time to

that of conventional timers, i.e., about 100 ms, during operation,             12 V DC                                                10 μF, 25 V

connect the Timer to a capacitor from the table as shown in the                24 V DC                                                4.7 μF, 50 V

following diagram. The reset time after the set time has elapsed will          5 and 6 V DC                                           22 μF, 16 V

vary with the load relay, so select an appropriate capacitor for the

load relay.

                                                                                             24        23  22                  21

                                                                                  C

                                                                                             1         2   3                   4

                                                                                                                                                                               7
                                                                                                                          H3FA

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H3FA-A, H3FA-B, H3FA-SA, H3FA-SB

                                                                      36.9                   Mounting holes  (Top  view)

                                                                                             H3FA-A/-B

                                17.75                                                                              Twelve, 1.0 dia. holes

                    17.75                                             36.9

            19.5

                                                                                             H3FA-SA/-SB

            0.5                                                                                                    Twelve, 1.0 dia. holes

            3.3     15.24                                       2.54                    0.6

                                0.4

                    Applicable Connecting Socket

                    Standard 24-pin IC socket can be used                   to   mount

                    the Timer.

H3FA-AU,  H3FA-BU,  H3FA-SAU, H3FA-SBU

                                                                      36.9                   Mounting holes (Top   View)

                                                                                             H3FA-AU/-BU

                                17.75

                    17.75                                             36.9

            19.5

                                                                                             H3FA-SAU/-SBU

            0.5

            3.3     15.24                                       2.54                    0.6

                                0.4

                    Applicable Connecting Socket

                    Standard 24-pin IC socket can be used                   for

                    mounting the Timer.

                                                                                                                                           8
                                                                                                                                                               H3FA

Safety Precautions

■ Precautions for Safe Use                                                 ■ Precautions for Correct Use

Observe the following items to ensure the safe use of this product.        •  Do not use excessive force to turn the time setting knob. Otherwise,

                                                                              it may be damaged.

Environmental Precautions                                                  •  When more precise operating time settings are required, measure

                                                                              the operating time prior to use and adjust the time setting knob

•  Store the H3FA within the specified ratings. If the H3FA has been          accordingly.

   stored at a temperature of –10°C or lower, let it stand for 3 hours or  •  Be very careful when handling terminal leads.

   longer at room temperature before turning ON the power supply.          •  Do not touch terminals with hands or objects that may be statically

•  Use the H3FA within the specified ratings for operating temperature        charged from mounting, transport, or other activities. Otherwise,

   and humidity.                                                              the terminals may be damaged. Discharge static prior to handling

•  Do not operate the H3FA in locations subject to sudden or extreme          the Timers by touching a grounded object or by using another

   changes in temperature, or locations where high humidity may               method.

   result in condensation.                                                 •  Refer to the following diagram for the set values for various

•  Do not use the H3FA in locations subject to vibrations or shock.           operating times.

   Extended use in such locations may result in damage due to stress.                  Operating time (%)

•  Do not use the H3FA in locations subject to excessive dust,                                             130

   corrosive gas, or direct sunlight.                                                                      120                                  Operating

                                                                                                                                                range

Usage Precautions                                                                                          100

• Install a switch or circuit breaker that allows the operator to                                          80

   immediately turn OFF the power, and label it to clearly indicate its

   function.                                                                                               60

• Be sure to wire the terminals correctly.

• Internal elements may be destroyed if a voltage outside the rated                                        40

   voltage is applied.

• Maintain voltage fluctuations in the power supply within the                                             20

   specified range.

                                                                                                           0    10  20  30  40  50  60  70  80  90 100
                                                                                                           (S)                                  (L)

                                                                                                                                                Set value (%)

                                                                           •  When cleaning the timer, confirm that the sealing tape is securely

                                                                              in place. Do not clean without this sealing tape affixed.

                                                                              Use alcohol type (IPA, ethanol) solvent, which are less chemically

                                                                              reactive. Note that use of other solvents may damage the materials

                                                                              used for the Timer. Clean the Timer in less than 2 minutes. The

                                                                              cleaning solution must be 50°C or less.

                                                                              The tails of the connecting leads are solder-plated with

                                                                              consideration given to temperature at the time of soldering. When

                                                                              soldering the leads, keep the temperature at 260°C±5°C and

                                                                              complete soldering within 10 s. Do not use ultrasonic cleaning.

                        ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                        To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                       In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                                     9
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)

from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.                     ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.                                OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS

IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products.   This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given.             This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

•  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

•  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

   safety equipment, and installations subject to separate industry or government regulations.

•  Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the products may be changed without any notice.     When in doubt, special model numbers may be assigned to fix or

establish key specifications for your application on your request.  Please consult with your OMRON representative at any time to confirm actual

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent               the

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

                                                                                                                                                                         2010.8

                                                      In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/

                                                                                                          (c)Copyright OMRON Corporation 2010 All Right Reserved.