器件描述

控制器 17.5mm timer Ca ge clamp

参数
制造商: Omron
产品种类: 控制器
RoHS:
零件号别名: H3DSSLCAC24230DC2448

H3DS-SLC AC24-230/DC24器件文档内容

Solid-state Timer

H3DS

DIN Track Mounted, Standard 17.5-mm Width Timer Range

• A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

230 VAC/VDC with H3DS-XL@)

• Smart Dial/Selector-locking Mechanism: Prevents the dials and selectors on the Timer’s front panel from being inadvertently op-

erated or being operated without authorization. The lock can only be unlocked and locked with an optional pen-type Lock Key.

• Screw-Less Clamp type available. (H3DS-@LC)

• Sticker provided for easy timer identification and management.

• Terminal clamp left open when delivered (screw terminal type).

• Finger protection terminal block to meet VDE0106/P100.

• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.

• Incorporates environment-friendly, cadmium-free contacts.

• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.

■ Broad Line-up of H3DS Series

                                                             H3DS

H3DS-M/S/A                  H3DS-F                                     H3DS-G                                                          H3DS-X

Standard Timer              Twin Timer                            Star-delta Timer                                                 Two-wired  Timer

H3DS-M (eight multi-modes)  H3DS-F                                H3DS-G                                                           H3DS-X

H3DS-S (four multi-modes)

H3DS-A (single mode)

                                                             Contents

                Solid-state Timer

                      H3DS-M/-S/-A...........................................................................................      2

                      H3DS-F.....................................................................................................  13

                      H3DS-G ....................................................................................................  20

                      H3DS-X ....................................................................................................  27

                Common to ALL Timers

                      Installation of Screw-Less Clamp Models.................................................                     33

                      Accessories ..............................................................................................   36

                      Precautions...............................................................................................   37

http://www.ia.omron.com/                                               (c)Copyright OMRON Corporation 2007                             All Rights Reserved.  1
    Solid-state Multi-functional Timer

    H3DS-M/-S/-A

• Eight operating modes (H3DS-M) and four operating modes

(H3DS-S) cover a wide range of applications.

• A wide time setting range of 0.10 s to 120 h.

• Two LEDs indicate power and relay status

respectively.

Model Number Structure

■ Model Number Legend

H3DS -         L

           1   2  3

1.  M:  Multi-function type

    S:  Standard type

    A:  Single-function type

2.  L:  Smart lock mechanism

3.  None:   Screw terminal type

    C:        Screw-Less Clamp type

Ordering Information

■ List of Models

        Supply voltage                Control output     Input type                Operating mode                       Model

                                                                                   (see note)          Screw terminal   Screw-Less

                                                                                                                  type  Clamp type

24 to 230 VAC (50/60Hz)/         Contact output: SPDT    Voltage input       Eight multi-modes: A, B,  H3DS-ML          H3DS-MLC

24 to 48 VDC                     (time-limit output SP-                      B2, C, D, E, G, J

                                 DT)                     No-input available  Four multi-modes: A, B2,  H3DS-SL          H3DS-SLC

                                                                             E, J

                                                                             Single mode: A            H3DS-AL          H3DS-ALC

Note: The operating modes are as follows:

        A:    ON-delay

        B:    Flicker OFF start

        B2: Flicker ON start

        C:    Signal ON/OFF-delay

        D:    SIgnal OFF-delay

        E:    Interval

        G:     Signal ON/OFF-delay

        J:    One shot

                  http://www.ia.omron.com/                                   (c)Copyright OMRON Corporation 2007  All Rights Reserved.  2
                                                                                                   H3DS-M/-S/-A

■ Accessories   (Order  Separately)

Lock Key                                                                        Y92S-38

Mounting Track                            50 cm (l) x 7.3 mm (t)                PFP-50N

                                          1 m (l) x 7.3 mm (t)                  PFP-100N

                                          1 m (l) x 16 mm (t)                   PFP-100N2

End Plate                                                                       PFP-M

Spacer                                                                          PEP-S

                http://www.ia.omron.com/                          (c)Copyright  OMRON Corporation  2007  All Rights Reserved.  3
                                                                                                                     H3DS-M/-S/-A

Specifications

■ General

           Item                           H3DS-ML@                                           H3DS-SL@                H3DS-AL@

Operating mode           A:   ON-delay (Signal or Power)                   A:      ON-delay                         A: ON-delay (fixed)

                         B:   Flicker OFF start (Signal or Power)          B2:     Flicker ON start

                         B2:  Flicker ON start (Signal or Power)           E:      Interval

                         C:   Signal ON/OFF-delay                          J:      One-shot

                         D:   Signal OFF-delay

                         E:   Interval (Signal or Power)

                         G:   Signal ON/OFF-delay

                         J:   One-shot (Signal or Power)

Input type               Voltage input                                     ---

Output type              Relay: SPDT

External connections     Screw terminal, Screw-Less Clamp

Terminal block           Screw terminal type:             Clamps two 2.5-mm2 max. bar terminals without sleeves.

                         Screw-Less Clamp type:           Clamps two 1.5-mm2 max. bar terminals without sleeves.

Terminal screw           0.98 N·m max.

tightening torque

Mounting method          DIN track mounting (see note)

Attachment               Nameplate label

Approved standards       UL508, CSA C22.2 No.14

                         Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

                         Output category according to IEC60947-5-1 (AC-13; 250 V 5 A/AC-14; 250 V 1 A/AC-15; 250 V 1 A/DC-13;            30  V      0.1  A/

                         DC-14; 30 V 0.05 A)

Note: Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges

       Time scale  display                      Time range

0.1 s                                0.1 to 1.2 s

1s                                   1 to 12 s

0.1 m                                0.1 to 1.2 min

1m                                   1 to 12 min

0.1 h                                0.1 to 1.2 h

1h                                   1 to 12 h

10 h                                 10 to 120 h

Note: When the time setting  dial  is set to “0” for any time scale,  the  output  will  operate  instantaneously.

■ Ratings

Rated supply voltage                            24 to 230 VAC (50/60 Hz)/24 to 48 VDC

(see notes 1 and 2)

Operating voltage range                         85% to 110% of rated supply voltage

Power reset                                     Minimum power-off time: 0.1 s

Reset voltage                                   2.4 VAC/DC max.

Power consumption (see note 3)                  AC: 32 VA max./3.0 W max. (typical: 30 VA/2.7 W) at 230 VAC

                                                     14 VA max./2.2 W max. (typical: 13 VA/2.1 W) at 100 to 120 VAC

                                                DC: 0.7 W max. (typical: 0.6 W) at 24 VDC

                                                     1.4 W max. (typical: 1.3 W) at 48 VDC

Voltage input                                   Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF

                                                Load connectable in parallel with inputs (terminals B1 and A1).

                                                H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC

                                                L-level: 0 to 2.4 VAC/DC

Control output                                  Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)

                                                            5 A at 30 VDC with resistive load (cosφ = 1)

Ambient temperature                             Operating: –10°C to 55°C (with no icing)

                                                Storage:  –25°C to 65°C (with no icing)

Ambient humidity                                Operating: 35% to 85%

Note: 1.   DC ripple rate: 20% max.

       2.  Since an inrush current of 0.5 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or off

           the power supply to the Timer with a solid-state output such as a sensor.

       3.  The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of

           the H3DS-ML includes the input circuit with the B1 and A1 terminals short-circuited.

                      http://www.ia.omron.com/                                               (c)Copyright OMRON Corporation 2007   All Rights Reserved.      4
                                                                                                                    H3DS-M/-S/-A

■ Characteristics

Accuracy of operating time  ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)

Setting error               ±10% ±50 ms max. of FS

Signal input time           50 ms min.

Influence of voltage        ±0.7% max. of FS (±0.7% ±10 ms max. at 1.2-s range)

Influence of temperature    ±5% max. of FS (±5%±10 ms max. at 1.2-s range)

Insulation resistance       100 MΩ min. at 500 VDC

Dielectric strength         Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for          1  min.

                            Between control output terminals and operating circuit: 2,000 VAC for 1 min.

                            Between contacts not located next to each other: 1,000 VAC for 1 min.

Vibration resistance        Malfunction: 0.5-mm single amplitude at 10 to 55 Hz

                            Destruction: 0.75-mm single amplitude at 10 to 55 Hz

Shock resistance            Malfunction: 100 m/s2 3 times each in 6 directions

                            Destruction: 1,000 m/s2 3 times each in 6 directions

Impulse withstand voltage   3 kV (between power terminals)

                            4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)

Noise immunity              Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV

Static immunity             Malfunction: 4 kV

                            Destruction: 8 kV

Life expectancy             Mechanical: 10 million operations min. (under no load at 1,800 operations/h)

                            Electrical:    100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)

                                           (see note)

EMC                         (EMI)                                  EN61812-1

                            Emission Enclosure:                    EN55011 Group 1 class B

                            Emission AC Mains:                     EN55011 Group 1 class B

                            Harmonic Current:                      EN61000-3-2

                            Voltage Fluctuation and Flickering:    EN61000-3-3

                            (EMS)                                  EN61812-1

                            Immunity ESD:                          EN61000-4-2:   6 kV contact discharge (level 3)

                                                                                  8 kV air discharge (level 3)

                            Immunity RF-interference from AM       Radio Waves:

                                                                   EN61000-4-3:   10 V/m (80 MHz to 1 GHz) (level 3)

                            Immunity Burst:                        EN61000-4-4:   2 kV power port and output port (level 3)

                                                                                  1 kV control port with capacitive clamp (level  3)

                            Immunity Surge:                        EN61000-4-5:   2 kV common mode (level 3)

                                                                                  1 kV differential mode (level 3)

Case color                  Light gray (5Y7/1)

Degree of protection        IP30 (Terminal block: IP20)

Weight                      Approx. 70 g

Note: For reference:

     A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).

     A maximum current of 0.1 A can be switched if L/R is 7 ms.

     In both cases, a life of 100,000 operations can be expected.

     The minimum applicable load is 10 mA at 5 VDC (failure level: P).

                 http://www.ia.omron.com/                                       (c)Copyright OMRON Corporation 2007      All Rights Reserved.  5
                                                                                                          H3DS-M/-S/-A

Connections

■ Block Diagram

H3DS-ML@

                          AC (DC) input                 Zero setting  Time scale/     Operating

                                                        detection     unit selectors  mode selector

                                                        circuit

                              Power supply              Oscillation   Counting        Output circuit

                              circuit                   circuit       circuit

                                          Start  input                Input circuit   Indicator

                                                                                      circuit

                                                                                      Power-ON            Output

                                                                                      indicator           indicator

H3DS-SL@/-AL@

                          AC  (DC) input         Zero setting         Time scale/     Operating

                                                 detection            unit selectors  mode selector

                                                 circuit

                              Power supply              Oscillation   Counting        Output circuit

                              circuit                   circuit       circuit

                                                                                      Indicator

                                                                                      circuit

                                                                                      Power-ON            Output

                                                                                      indicator           indicator

■ I/O   Functions

          Item                                   H3DS-ML@                                        H3DS-SL@/-AL@

Input     Start               Starts operation.                                   No input is available.

Output    Control output      Outputs are turned ON according to designated out-  Outputs are turned ON according to designated out-

                              put mode when preset value is reached.              put mode when preset value is reached.

                 http://www.ia.omron.com/                             (c)Copyright OMRON Corporation 2007            All Rights Reserved.  6
                                                                                                                                       H3DS-M/-S/-A

■ Terminal Arrangement

H3DS-MLC                 H3DS-ML                                               H3DS-SLC/-ALC                   H3DS-SL/-AL

A1      15  B1                                                                 A1      15

                         A1      15  B1                                                                        A1         15

                                              L

    15                       15                                                    15                              15

18      16               18      16                                            18      16                      18         16

                         18      16  A2                                                                        18         16  A2

18      16  A2                                   (see  note  1)                18      16         A2                              (see note 1)

            (DIN  notation)                                                                              (DIN  notation)

Note: 1.    DC supply voltage does not require the designation of polarity.

        2.  The contact symbol for the H3DS is indicated with             because it offers multiple           operating modes    and is different from    the  delayed

            contact for conventional timers.

■ Input Connections

The inputs of the H3DS-ML@ are voltage (voltage imposition or open) inputs.

No-contact Input                                             No-contact Input                                  Contact Input

(Connection to PNP output sensor.)                           (Connection to NPN output sensor.)

        Sensor

                                                                                                  Timer

                                                             (+)               A2

                                     Timer                        24 VDC                                                                            Timer

                                                             (−)

                                 A1                                       B1       A1

(+)               B1                                                                                                              B1            A1

        24 VDC    Start                                                                                                           Start

(−)                      A2                                                                                                              A2

Operates with PNP transistor ON                                   Sensor                                       Operates with relay ON

                                                                 Operates with NPN transistor ON

Voltage Input Signal Levels

                1. Transistor ON

                Residual voltage: 1 V max.

No-contact      (Voltage between terminals B1 and A2 must be more than the rated "H-level" voltage (20.4 VDC min.).)

input           2. Transistor OFF

                Leakage current: 0.01 mA max.

                (Voltage between terminals B1 and A2 must be less than the rated "L-level" voltage (2.4 VDC max.).)

Contact         Use contacts that can adequately switch 0.1 mA at each voltage to be imposed. (When the contacts are

                ON or OFF, voltage between terminals B1 and A2 must be within the following ranges:

input           When contacts are ON:            20.4 to 253 VAC/20.4 to 52.8 VDC

                When contacts are OFF:           0 to 2.4 VAC/DC

                  http://www.ia.omron.com/                                                        (c)Copyright OMRON Corporation 2007    All Rights Reserved.            7
                                                                                                      H3DS-M/-S/-A

Operation

■ Basic Operation

Setting of Selector                                                                Locking/Unlocking of Selectors and

The   selectors  can  be  turned     clockwise     and      counterclockwise  to   Time Setting Dial

select the desired time scale, or operating mode.

Each selector has a snap mechanism that secures the selector at a                  The time setting dial, time scale selector, and operating mode selec-

given position. Set the selector at a position at which it is secured. Do          tor can be locked using the Y92S-38 Lock Key, a special pen type

not set it midway between two securing positions or a malfunction                  tool that is sold separately. To lock the dial or selectors, insert the

could result from improper setting.                                                Lock Key in the keyhole to the lower right of the dial or selector and

                                                                                   turn it clockwise until the dial or selector is completely covered with

Selection of Operating Mode (except                                                the red cover. To unlock, turn the Lock Key in the opposite direction.

for H3DS-AL)

The H3DS-ML/-SL can be set to any one of the operating modes A to

J.  Turn  the  operating  mode      selector  with  a    screwdriver  until   the

desired operating mode appears in the operating mode display win-

dow.

H3DS-ML (8 modes): A, B, B2, C, D, E, G, J

                          (In order of appearance)

H3DS-SL (4 modes):        A, E, B2, J, E, E, J, J

                          (In order of appearance)

Note: Letters that appear more than once indicate exactly the same                                                      Key hole

      operating mode.

Selection of Time Scale

The time scale is selected by turning the time scale selector. The

time scales will appear in the following order in the time scale display

window on the left of the selector:

1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, 0.1 m.

Note: The time scale “1h” appears twice. Both instances indicate ex-

      actly the same time scale.

               Time scale display

               window and selector

                                    Operating mode display

                                    window and selector

                          http://www.ia.omron.com/                                 (c)Copyright OMRON Corporation 2007  All Rights Reserved.                8
                                                                                                                                            H3DS-M/-S/-A

■ Timing Chart

Note: 1.   The minimum power reset time is 0.1 s and the minimum signal input time is 0.05 s.

       2.  The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.

       3.  There is no start input for H3DS-SL@/-AL@ models. Operation starts at power-on.

    Operating                                                                    Timing chart

       mode

A: ON-delay                           t                   t–a              t

               Power (A1 and A2)                                                                  Basic operation

               Start (B1 and A2)                                                               Power

               (see note)                                                                                       **

                                                                                                  *
                                                                                                  Start

               Output relay: NC                                                                                                 t

               15 and 16

                                                                                               Output

               Output relay: NO                                                                *     For power-on operation, impose voltage to the

               (output indicator)                                                                    Start input. The Timer starts operating at the

               15 and 18                                                                             moment the power is turned on.

                                                                                               ** Start input is invalid while the Timer is in

               Power indicator                                                                       operation.

B:                                 t        t     t–a     t          t        t     t–a

Flicker OFF

start                                                                                          Basic operation

               Power (A1 and A2)

                                                                                               Power

               Start (B1 and A2)                                                                            **

               (see note)                                                                         *

                                                                                               Start

               Output relay: NC                                                                                           t           t             t              t

               15 and 16

                                                                                               Output

               Output relay: NO

               (output indicator)                                                              *     For power-on operation, impose voltage to the

               15 and 18                                                                             Start input. The Timer starts operating at the

                                                                                                     moment the power is turned on.

                                                                                               ** Start input is invalid while the Timer is in

               Power indicator                                                                       operation.

B2:                                   t        t     t–a       t        t        t       t–a

Flicker ON

start          Power (A1 and A2)

                                                                                                  Basic operation

               Start (B1 and A2)                                                                  Power

               (see note)

                                                                                                     *          **

               Output relay: NC                                                                      Start

               15 and 16                                                                                                     t           t              t             t

               Output relay: NO                                                                   Output

               (output indicator)                                                                 *  For power-on operation, impose voltage to the

               15 and 18                                                                             Start input. The Timer starts operating at the

                                                                                                     moment the power is turned on.

               Power indicator                                                                    ** Start input is invalid while the Timer is in

                                                                                                     operation.

C:                                       t        t               t     t–a      t       t–a

Signal

ON/OFF-

delay          Power (A1 and A2)

               Start (B1 and A2)                                                                     Basic operation

               (see note)

               Output relay: NC                                                                Power

               15 and 16                                                                                               *

               Output relay: NO                                                                Start

               (output indicator)                                                                                   t              t             t              t

               15 and 18                                                                       Output

               Power indicator                                                                 *     Start input is invalid while           the  Timer  is  in

                                                                                                     operation.

Note:  The   start input of the H3DS-ML@ model is activated by applying a voltage to B1        and A2 terminals.

       The   voltage can be applied by turning on the contact between B1 and A1 (Refer         to Terminal Arrangement).

               http://www.ia.omron.com/                                             (c)Copyright OMRON Corporation 2007                             All Rights Reserved.  9
                                                                                                                                            H3DS-M/-S/-A

    Operating                                                                      Timing    chart

     mode

D:                                             t              t–a          t–a          t       t–a

Signal

OFF-delay

               Power (A1 and A2)

                                                                                                         Basic operation

               Start (B1 and A2)

               (see note)

                                                                                                         Power

               Output relay: NC                                                                                              *

               15 and 16

                                                                                                            Start

               Output relay: NO                                                                                                             t

               (output indicator)                                                                        Output

               15 and 18

                                                                                                            *  Start input is valid and re-triggerable while the

               Power indicator                                                                                 Timer is in operation.

E: Interval                                 t              t          t–a               t–a     t

                                                                                                               Basic operation

               Power (A1 and A2)

                                                                                                         Power

               Start (B1 and A2)                                                                               *      **

               (see note)                                                                                      Start

               Output relay: NC                                                                                                 t

               15 and 16

                                                                                                         Output

               Output relay: NO                                                                             *      For power-on operation, impose voltage to the

               (output indicator)                                                                                  Start input. The Timer starts operating at the

               15 and 18                                                                                           moment the power is turned on.

                                                                                                            **     Start input is valid and re-triggerable while the

               Power indicator                                                                                     Timer is in operation.

G:                                             t  t           t–a  t            t       t–a  t      t–a        Basic operation

Signal

ON/OFF-        Power (A1 and A2)                                                                         Power

delay          Start (B1 and A2)

               (see note)                                                                                                 *

               Output relay: NC                                                                          Start

               15 and 16                                                                                              t         t              t                t

               Output relay: NO                                                                          Output

               (output indicator)

               15 and 18                                                                                    *     Start input is valid and  re-triggerable  while  the

               Power indicator                                                                                     Timer is in operation.

J:                                 t                 t                t–a          t–a       t                 Basic operation

One-shot out-

put            Power (A1 and A2)                                                                         Power

(ON delay)

               Start (B1 and A2)                                                                                      **

               (see note)                                                                                *
                                                                                                         Start
               Output relay: NC

               15 and 16                                                                                                     t

                                   Approx.        Approx.                          Approx.               Output                                Approx. 1±0.6 s

               Output relay: NO    1±0.6 s        1±0.6 s                          1±0.6 s                                                     (fixed)

               (output indicator)  (fixed)        (fixed)                          (fixed)                     *   For power-on operation, impose voltage to the

               15 and 18                                                                                           Start input. The Timer starts operating at the

                                                                                                                   moment the power is turned on.

               Power indicator                                                                                 **  Start input is valid and re-triggerable while the

                                                                                                                   Timer is in operation.

Note: The start input of the H3DS-ML@ model is activated by applying a voltage to B1 and A2 terminals.

       The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement).

               http://www.ia.omron.com/                                                         (c)Copyright OMRON Corporation 2007                     All Rights Reserved.  10
                                                                                                                           H3DS-M/-S/-A

Nomenclature

H3DS-ML@/-SL@                                                                        H3DS-MLC/-SLC

                                                                                                   Wire connection holes

Output indicator (orange)

(Lit while Timer output is ON.)

Set time window                                    Time setting dial (set time)

                                                   Lock for time setting dial

Time scale display window and

selector (select one from 1 s,                     Lock for time scale selector                    Release holes

0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m,

and 0.1 m)

                                                   Lock for operating mode selector

Operating mode display window

and selector (select the mode from

A, B, B2, C, D, E, G, and J for the                Power-ON indicator (green)

H3DS-ML, from A, B2, E, and J for                  (Lit while the power is ON.)      18  16  A2

the H3DS-SL)

                                                                                                   Wire connection  holes

                                     (Front View)

                                                                                     (Front View)

H3DS-AL@                                                                             H3DS-ALC

                                                                                                   Wire connection  holes

Output indicator (orange)

(Lit while Timer output is ON.)

Set time window                                    Time setting dial (set time)

                                                   Lock for time setting dial

Time scale display window and

selector (select one from 1 s,                     Lock for time scale selector                    Release holes

0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m,

and 0.1 m)

                                                   Power-ON indicator (green)        18  16  A2

                                                   (Lit while the power is ON.)

                                                                                                   Wire connection holes

                                     (Front View)

                                                                                     (Front View)

                                                   Attach the enclosed label here as a nameplate.

                                                   (The label is attached to the Timer's DIN Track

                                                   hook section at the time of shipment.)

                 http://www.ia.omron.com/                                            (c)Copyright OMRON Corporation 2007   All Rights Reserved.  11
                                                                                                              H3DS-M/-S/-A

Dimensions

Note: All units are in millimeters  unless  otherwise indicated.

H3DS-ML/-SL/-AL

                                                                  Surface color:  Light  gray 5Y7/1  (OMRON)

H3DS-MLC/-SLC/-ALC

                                            17.5                  73

                                                  45                                     80

                                                                      44

                                                                  68

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                    In the interest of product improvement, specifications are subject to change without notice.

                 http://www.ia.omron.com/                                                (c)Copyright OMRON Corporation 2007      All Rights Reserved.  12
Solid-state Twin Timer

H3DS-F

• Operates in flicker-OFF or flicker-ON start mode with one Unit.

• Independent ON- and OFF-time settings.

Combinations of long ON- or OFF-time and short OFF- or ON-

time setting are possible.

• Long time range from 0.1 s to 12 h for both ON and OFF time

settings.

Model Number Structure

■ Model Number Legend

H3DS -F    L

        1  2    3

1. F:  Twin timers

2. L:  Smart lock mechanism

3. None: Screw terminal type

C:      Screw-Less Clamp type

Ordering Information

■ List of Models

           Operating mode                 Supply voltage                                                    Model

                                                                            Screw terminal type                   Screw-Less Clamp type

Flicker-OFF/Flicker-ON start   24 to 230 VAC (50/60 Hz)/24 to      48  VDC  H3DS-FL                         H3DS-FLC

■ Accessories                 (Order Separately)

Lock Key                                                                             Y92S-38

Mounting Track                            50 cm (l) x 7.3 mm (t)                     PFP-50N

                                          1 m (l) x 7.3 mm (t)                       PFP-100N

                                          1 m (l) x 16 mm (t)                        PFP-100N2

End Plate                                                                            PFP-M

Spacer                                                                               PEP-S

                http://www.ia.omron.com/                                    (c)Copyright OMRON Corporation  2007   All Rights Reserved.  13
                                                                                                                                 H3DS-F

Specifications

■ General

                   Item                                                                H3DS-F

Operating mode                               Flicker-OFF/Flicker-ON start

Output type                                  Relay: SPDT

External connections                         Screw terminal, Screw-Less Clamp

Terminal block                               Screw terminal type:    Clamps two 2.5-mm2 max. bar terminals without sleeves.

                                             Screw-Less Clamp type:  Clamps two 1.5-mm2 max. bar terminals without sleeves.

Terminal screw tightening   torque           0.98 N·m max.

Mounting method                              DIN track mounting (see note)

Attachment                                   Nameplate label

Approved standards                           UL508, CSA C22.2 No.14

                                             Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P 100

                                             Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13;         30  V  0.1  A)

Note: Can be mounted to 35-mm DIN   Track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges

       Time scale  display                   Time range

0.1 s                             0.1 to 1.2 s

1s                                1 to 12 s

0.1 m                             0.1 to 1.2 min

1m                                1 to 12 min

0.1 h                             0.1 to 1.2 h

1h                                1 to 12 h

Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.

■ Ratings

Rated supply voltage (See note.)                  24 to 230 VAC (50/60 Hz)/24 to 48 VDC

Operating voltage range                           85% to 110% of rated supply voltage

Power reset                                       Minimum power-off time: 0.1 s

Reset voltage                                     2.4 VAC/DC max.

Power consumption                                 AC: 33 VA max./2.2 W max. (typical: 31 VA/2.0 W) at 230 VAC

                                                          11 VA max./1.9 W max. (typical: 9.7 VA/1.7 W) at 100 to 120  VAC

                                                  DC: 0.7 W max. (typical: 0.6 W) at 24 VDC

                                                          1.4 W max. (typical: 1.2 W) at 48 VDC

Voltage input                                     Max. permissible capacitance between inputs lines (terminals B1      and A2):  2,000  pF

                                                  Load connectable in parallel with inputs (terminals B1 and A1).

                                                  H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC

                                                  L-level: 0 to 2.4 VAC/DC

Control output                                    Contact output:    5 A at 250 VAC with resistive load (cosφ = 1)

                                                                     5 A at 30 VDC with resistive load (cosφ = 1)

Ambient temperature                               Operating: –10°C to 55°C (with no icing)

                                                  Storage:         –25°C to 65°C (with no icing)

Ambient humidity                                  Operating: 35% to 85%

Note: DC ripple rate: 20% max.

                      http://www.ia.omron.com/                                    (c)Copyright OMRON Corporation 2007        All Rights Reserved.       14
                                                                                                                                    H3DS-F

■ Characteristics

Accuracy of operating time  ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)

Setting error               ±10% ± 50 ms max. of FS

Influence of voltage        ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range)

Influence of temperature    ±5% max. of FS (±5% ± 10 ms max. at 1.2-s range)

Insulation resistance       100 MΩ min. at 500 VDC

Dielectric strength         Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60         Hz)  for  1

                            min.

                            Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.

                            Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.

Impulse withstand voltage   3 kV (between power supply terminals)

                            4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)

Noise immunity              Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV

Static immunity             Malfunction: 4 kV

                            Destruction: 8 kV

Vibration resistance        Malfunction: 0.5-mm single amplitude at 10 to 55 Hz

                            Destruction: 0.75-mm single amplitude at 10 to 55 Hz

Shock resistance            Malfunction: 200 m/s2, 3 times each in 6 directions

                            Destruction: 300 m/s2, 3 times each in 6 directions

Life expectancy             Mechanical: 10 million operations min. (under no load at 1,800 operations/h)

                            Electrical:    100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) (see note)

EMC                         (EMI)                                  EN61812-1

                            Emission Enclosure:                    EN55011 Group 1 class B

                            Emission AC Mains:                     EN55011 Group 1 class B

                            Harmonic Current:                      EN61000-3-2

                            Voltage Fluctuation and Flickering:    EN61000-3-3

                            (EMS)                                  EN61812-1

                            Immunity ESD:                          EN61000-4-2:   6 kV contact discharge (level 3)

                                                                                  8 kV air discharge (level 3)

                            Immunity RF-interference from AM       Radio Waves:

                                                                   EN61000-4-3:   10 V/m (80 MHz to 1 GHz) (level 3)

                            Immunity Burst:                        EN61000-4-4:   2 kV power port and output port (level 3)

                                                                                  1 kV control port with capacitive clamp (level    3)

                            Immunity Surge:                        EN61000-4-5:   2 kV common mode (level 3)

                                                                                  1 kV differential mode (level 3)

Case color                  Light gray (5Y7/1)

Degree of protection        IP30 (IP20 for terminal block)

Weight                      Approx. 70 g

Note: For reference:

     A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).

     A maximum current of 0.1 A can be switched if L/R is 7 ms.

     In both cases, a life of 100,000 operations can be expected.

     The minimum applicable load is 10 mA at 5 VDC (failure level: P).

                 http://www.ia.omron.com/                                        (c)Copyright OMRON Corporation 2007  All Rights Reserved.           15
                                                                                                                                                H3DS-F

Connections

■ Block Diagram

                                   ON                 OFF

                                   indicator          indicator

                                   (Orange)           (Green)                               ON/OFF start

                                                                                            selector

          AC (DC)                      Indicator                                                                  Time scale

          input                        circuit                                                                    selector

                                                                 ROM                   RAM         Clock

                          Power                                            One-chip microcomputer

                          supply                                                                                  Output

                          circuit                                                                                 circuit

■ I/O Function

Inputs                             Flicker-ON start operation begins when inputs are           turned ON.

Outputs   Control output           Outputs are turned ON/OFF according to the time             set by the ON-and  OFF-time      setting  dial.

■ Terminal Arrangement

                                       H3DS-FLC                            H3DS-FL

                                              A1      15   B1

                                                                           A1  15      B1

                                                                                            L

                                                  15                           15

                                              18      16                   18      16

                                                                           18  16      A2

                                              18      16   A2

                                                                                               (See note 2.)

Note: 1.  If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the  operating mode    is  switched  to  flicker-ON  start  mode.  If  these

          terminals are disconnected, the mode switches to flicker-OFF start mode.

2.        DC supply voltage does not require the designation of polarity.

          http://www.ia.omron.com/                                                          (c)Copyright OMRON Corporation 2007          All Rights Reserved.        16
                                                                                                                                             H3DS-F

Operation

■ Basic Operation

Setting of Selector                                                            Time Setting

The    selectors  can  be  turned  clockwise       and  counterclockwise   to  Use the ON/OFF-time setting dials to set the ON/OFF time.

select the desired time scale, or operating mode.

Each selector has a snap mechanism that secures the selector at a              Locking/Unlocking of Selectors and

given position. Set the selector at a position at which it is secured. Do      Time Setting Dial

not set it midway between two securing positions or a malfunction

could result from improper setting.

                                                                               The   ON/OFF-time         setting  dials  and  time    scale  selectors  can  be

Settings for ON/OFF Start                                                      locked using the Y92S-38 Lock Key, a special pen type tool that is

                                                                               sold separately. To lock the dials or selectors, insert the Lock Key in

If voltage is applied to terminal B1, or if terminals A1 and B1 are            the keyhole to the lower right of the dial or selector and turn it clock-

shorted, the operating mode is switched to flicker-ON start mode. If           wise until the dial or selector is completely covered with the red

these terminals are disconnected, the mode switches to flicker-OFF             cover. To unlock, turn the Lock Key in the opposite direction.

start mode. The operating mode will not change if the state of the

applied voltage changes during timer operation.

Selection of Time Scale

The time scale is selected by turning the ON-time scale selector and

OFF-time scale selector. The time scales will appear in the following

order in each time scale display window on the left of the selector:

0.1 s, 1 h, 0.1 h, 1 m, 1 s, 0.1 h, 0.1 m, 1 s.

Note: The time scales “1 s” and “0.1 h” appear twice. Both instances

       indicate exactly the same time scale.

                                                                                                                                             Key hole

                  ON-time scale

                  display window

                  and selector

                                   OFF-time scale display

                                   window and selector

■    Timing            Charts

Operating                                                                      Timing chart

     mode

Flicker-OFF                                                                                  0.1 s min.

start                              Power (A1 and A2)       ON

(See note 1.)                                              OFF

                                   Output relay: NO        ON

                                   15 and 18               OFF

                                   (ON indicator)

                                   Output relay: NC        ON

                                   15 and 16               OFF                                                    tON: ON set time

                                   OFF indicator           ON                                                     tOFF: OFF set time

                                                           OFF

Flicker-ON                                                                                   0.1 s min.

start                              Power (A1 and A2)       ON

(See note 1.)                                              OFF

                                   Signal (B1 and A2)      ON

                                                           OFF

                                   Output relay: NO        ON

                                   15 and 18               OFF

                                   (ON indicator)

                                   Output relay: NC        ON

                                   15 and 16               OFF                                                    tON: ON set time

                                   OFF indicator           ON                                                     tOFF: OFF set time

                                                           OFF

Note: 1.   If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to flicker-ON start mode. If these

           terminals are disconnected, the mode switches to flicker-OFF start mode.

       2.  The reset time requires a minimum of 0.1 s.

       3.  When power is supplied in flicker-ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance

           of the Timer.

                  http://www.ia.omron.com/                                           (c)Copyright OMRON Corporation 2007            All Rights Reserved.     17
                                                                                                                                   H3DS-F

Nomenclature

H3DS-FL@                                                                                    H3DS-FLC

                                                                                                           Wire connection  holes

                                                          Output ON/OFF indicator

                                                          When the output is ON: Orange

                                                          When the output is OFF: Green

ON-time display window                                    ON-time setting dial

                                                          Lock for ON-time setting dial

ON-time scale display window

and selector (select one from                             Lock for ON-time scale selector

0.1 s, 1 s, 0.1 m, 1 m, 0.1 h,

and 1 h)                                                  OFF-time setting dial                            Release holes

OFF-time display window                                   Lock for OFF-time setting dial

OFF-time scale display window

and selector (select one from                             Lock for OFF-time scale selector

0.1 s, 1 s, 0.1 m, 1 m, 0.1 h,

and 1 h)

                                                                                            18  16  A2

                                (Front View)                                                               Wire connection  holes

                                                                                            (Front View)

                                                          Attach the enclosed label here as a nameplate.

                                                          (The label is attached to the Timer's DIN Track

                                                          hook section at the time of shipment.)

                                http://www.ia.omron.com/                                    (c)Copyright OMRON Corporation 2007    All Rights Reserved.  18
                                                                                                                       H3DS-F

Dimensions

H3DS-FL

                                                        Surface color:  Light gray 5Y7/1 (OMRON)

                                    17.5                73

                                                    45                  80

                                                            44

                                                        68

H3DS-FLC

                                                        Surface color:  Light gray 5Y7/1 (OMRON)

                                    17.5                73

                                                    45                  80

                                                            44

                                                        68

          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

            In the interest of product improvement, specifications are subject to change without notice.

          http://www.ia.omron.com/                      (c)Copyright OMRON Corporation 2007  All Rights Reserved.              19
Solid-state Star-delta Timer

H3DS-G

• A wide star-time range (up to 120 seconds) and star-delta trans-

fer time range (up to 1 second)

Model Number Structure

■ Model Number Legend

H3DS -G      L

          1  2  3

1. G: Star-delta timer

2. L:   Smart lock mechanism

3. None: Screw terminal type

C:           Screw-Less Clamp type

Ordering Information

■ List of Models

           Operating mode                 Supply voltage                                                      Model

                                                                              Screw terminal type                   Screw-Less Clamp type

Star-delta operation                24  to 230 VAC (50/60 Hz)/24 to  48  VDC  H3DS-GL                         H3DS-GLC

■ Accessories (Order                    Separately)

Lock Key                                                                      Y92S-38

Mounting Track                            50 cm (l) x 7.3 mm (t)              PFP-50N

                                          1 m (l) x 7.3 mm (t)                PFP-100N

                                          1 m (l) x 16 mm (t)                 PFP-100N2

End Plate                                                                     PFP-M

Spacer                                                                        PEP-S

                http://www.ia.omron.com/                                      (c)Copyright OMRON Corporation  2007   All Rights Reserved.  20
                                                                                                                               H3DS-G

Specifications

■ General

                Item                                                                 H3DS-G

Operating mode                         Star-delta operation

Operating/Reset method                 Time-limit operation/Self-reset

External connections                   Screw terminal, Screw-Less Clamp

Terminal block                         Screw terminal type:     Clamps two 2.5-mm2 max. bar terminals without sleeves.

                                       Screw-Less Clamp type:   Clamps two 1.5-mm2 max. bar terminals without sleeves.

Terminal screw tightening torque       0.98 N·m max.

Output type                            (Star operation circuit) Relay:   SPST-NO

                                       (Delta operation circuit) Relay:  SPST-NO

Mounting method                        DIN track mounting (see note)

Attachment                             Nameplate label

Approved standards                     UL508, CSA C22.2 No.14

                                       Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

                                       Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13;      30 V 0.1 A)

Note: Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges

       Time  scale              Star operation time ranges

x  1                      1 to 12 s

x  10                     10 to 120 s

Star-delta transfer time               Programmable at 0.05 s, 0.1 s, 0.5 s, or 1 s

■ Ratings

Rated supply voltage (see note)                       24 to 230 VAC (50/60 Hz)/24 to 48 VDC

Operating voltage range                               85% to 110% of rated supply voltage

Power reset                                           Minimum power-off time: 0.5 s

Reset voltage                                         2.4 VAC/DC max.

Power consumption                                     AC: 21 VA max./1.7 W max. (typical: 20 VA/1.6 W) at 230 VAC

                                                             11 VA max./2.0 W max. (typical: 8.6 VA/1.5 W) at 100 to 120  VAC

                                                      DC: 1.3 W max. (typical: 1.2 W) at 24 VDC

                                                             0.7 W max. (typical: 0.6 W) at 48 VDC

Control output                                        Contact output:    5 A at 250 VAC with resistive load (cosφ = 1)

                                                                         5 A at 30 VDC with resistive load (cosφ = 1)

Ambient temperature                                   Operating: –10°C to 55°C (with no icing)

                                                      Storage:  –25°C to 65°C (with no icing)

Ambient humidity                                      Operating: 35% to 85%

Note: DC ripple rate: 20% max.

                    http://www.ia.omron.com/                                      (c)Copyright OMRON Corporation 2007     All Rights Reserved.  21
                                                                                                                                   H3DS-G

■ Characteristics

Accuracy of operating time   ±1% max. of FS

Setting error                ±10% ± 50 ms max. of FS

Total tolerance of transfer  ± (25% FS + 5 ms) max.

time

Influence of voltage         ±0.5% max. of FS

Influence of temperature     ±5% max. of FS

Insulation resistance        100 MΩ min. at 500 VDC

Dielectric strength          Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60        Hz)  for    1

                             min.

                             Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.

                             Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.

Impulse withstand voltage    3 kV (between power supply terminals)

                             4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)

Noise immunity               Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV

Static immunity              Malfunction: 4 kV

                             Destruction: 8 kV

Vibration resistance         Malfunction: 0.5-mm single amplitude at 10 to 55 Hz

                             Destruction: 0.75-mm single amplitude at 10 to 55 Hz

Shock resistance             Malfunction: 200 m/s2, 3 times each in 6 directions

                             Destruction: 300 m/s2, 3 times each in 6 directions

Life expectancy              Mechanical: 10 million operations min. (under no load at 1,800 operations/h)

                             Electrical:   100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) (see note)

EMC                          (EMI)                                  EN61812-1

                             Emission Enclosure:                    EN55011 Group 1 class B

                             Emission AC Mains:                     EN55011 Group 1 class B

                             Harmonic Current:                      EN61000-3-2

                             Voltage Fluctuation and Flickering:    EN61000-3-3

                             (EMS)                                  EN61812-1

                             Immunity ESD:                          EN61000-4-2:   6 kV contact discharge (level 3)

                                                                                   8 kV air discharge (level 3)

                             Immunity RF-interference from AM       Radio Waves:

                                                                    EN61000-4-3:   10 V/m (80 MHz to 1 GHz) (level 3)

                             Immunity Burst:                        EN61000-4-4:   2 kV power port and output port (level 3)

                                                                                   1 kV control port with capacitive clamp (level   3)

                             Immunity Surge:                        EN61000-4-5:   2 kV common mode (level 3)

                                                                                   1 kV differential mode (level 3)

Case color                   Light gray (5Y7/1)

Degree of protection         IP30 (IP20 for terminal block)

Weight                       Approx. 70 g

Note: For reference:

      A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).

      A maximum current of 0.1 A can be switched if L/R is 7 ms.

      In both cases, a life of 100,000 operations can be expected.

      The minimum applicable load is 10 mA at 5 VDC (failure level: P).

                       http://www.ia.omron.com/                                    (c)Copyright OMRON Corporation 2007        All Rights Reserved.     22
                                                                                                                                                         H3DS-G

Connections

■ Block Diagram

           AC (DC) input                                 Star           Star-delta

                                                         operation      transfer

                                                         time scale     time

                                                         selector       selection

                                       Star              Star           Star-delta         Star-delta

                   Power               operation         operation      transfer time      transfer                                     Star operation

                   supply              time              time           oscillation        time

                   circuit             oscillation       counting       circuit            counting    Output

                                       circuit           circuit                           circuit     circuit

                                                                                                                                        Delta operation

                                                                                                       Indicator

                                                                                                       circuit

                                                                                                       Star operation  Delta operation

                                                                                                       indicator       indicator

■ I/O Functions

Inputs                                                         ---

Outputs                     Control output                     Star output is turned OFF when          the dial set value is reached    and  delta       output  is  ON  after

                                                               the preset transfer time elapses

■ Terminal Arrangement

                                                     H3DS-GLC                      H3DS-GL

                                                     A1  17         27

                                                                                   A1  17  27

                                                     17  27                        17  27

                                                     18  28                        18  28

                                                                                   18  28  A2

                                                     18  28       A2                                   (see note)

Note:  DC  supply  voltage  does  not  require  the  designation of     polarity.

                   http://www.ia.omron.com/                                                (c)Copyright OMRON Corporation 2007               All Rights Reserved.               23
                                                                                                                                   H3DS-G

Operation

■ Basic Operation

Setting of Selector                                                                           Time Setting

The  selectors  can     be  turned    clockwise  and  counterclockwise            to          The star operation time of the Timer is set with the time setting dial.

select the desired time scale, or operating mode.

Each selector has a snap mechanism that secures the selector at a                             Locking/Unlocking of Selectors and

given position. Set the selector at a position at which it is secured. Do                     Time Setting Dial

not set it midway between two securing positions or a malfunction

could result from improper setting.                                                           The time setting dial and time scale selector can be locked using the

Selection of Time Unit and Time Scale                                                         Y92S-38 Lock Key, a special pen type tool that is sold separately. To

                                                                                              lock the dial or selectors, insert the Lock Key in the keyhole to the

The star-delta transfer time and star operation time scale are set with                       lower right of the dial or selector and turn it clockwise until the dial or

the same selector. The star-delta transfer time can be set to 0.05,                           selector is completely covered with the red cover. To unlock, turn the

0.1, 0.5, or 1. The star operation time scale can be set to a multiplica-                     Lock Key in the opposite direction.

tion factor of 1 or 10. If the star-delta transfer time is displayed in the

display window in white letters, this means that the star operation

time scale is “x10”. Refer to the example below.

     Star-delta transfer time              Star operation time scale

                0.05 s                x1

                0.1 s

                0.5 s

                1s

                0.05 s                x10

                0.1 s                                                                                                              Key hole

                0.5 s

                1s

       Star-delta transfer time and

       star operation time scale

       display window and selector

■ Timing Charts

                                                                                      0.5  s

                   Power (A1 and A2)  ON

                                      OFF

                   Star contact                   t1     t2

                   17 and 18          ON

                   (star indicator)   OFF

                   Delta contact      ON

                   27 and 28          OFF

                   (delta indicator)             t1: Star operation time setting

                                                 t2: Star-delta transfer time

Note:  The  reset  time requires a    maximum of 0.5 s.

                        http://www.ia.omron.com/                                              (c)Copyright OMRON Corporation 2007  All Rights Reserved.                    24
                                                                                                                              H3DS-G

Nomenclature

H3DS-GL@                                                                        H3DS-GLC

                                                                                                      Wire connection  holes

                                            Delta operation indicator (orange)

Set time window                             Time setting dial (for setting

                                            star operation time)

Star-delta transfer time and                Lock for time setting dial

star operation time scale                   Lock for star-delta transfer time                         Release holes

display window and selector                 and star operation time scale

                                            Star operation indicator

                                            (green)

                                                                                18           28 A2

                                                                                                      Wire connection  holes

                              (Front View)

                                                                                (Front View)

                                                     Attach the enclosed label here as a nameplate.

                                                     (The label is attached to the Timer's DIN Track

                                                     hook section at the time of shipment.)

                 http://www.ia.omron.com/                                       (c)Copyright OMRON Corporation 2007    All Rights Reserved.  25
                                                                                                                            H3DS-G

Dimensions

H3DS-GL

                                                    Surface color:  Light gray 5Y7/1 (OMRON)

                                    17.5            73

                                          45                        80

                                                        44

                                                    68

H3DS-GLC

                                                    Surface color:  Light gray 5Y7/1 (OMRON)

                                    17.5            73

                                          45                        80

                                                        44

                                                    68

          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

            In the interest of product improvement, specifications are subject to change without notice.

          http://www.ia.omron.com/                                  (c)Copyright OMRON Corporation 2007                All  Rights Reserved.  26
Solid-state Two-wired Timer

H3DS-X

• Covers wide range of supply voltage

(24 to 230 VAC/VDC).

Model Number Structure

■ Model Number Legend

H3DS -X      L

          1  2  3

1. X:   Two-wired timer

2. L:   Smart lock mechanism

3. None: Screw terminal type

C:           Screw-Less Clamp type

Ordering Information

■ List of Models

             Supply voltage                  Input type              Operating mode                       Model

                                                                                     Screw terminal  type  Screw-Less  Clamp

                                                                                                                 type

24 to 230 VAC/VDC (50/60 Hz)        No-input available   ON-delay                    H3DS-XL               H3DS-XLC

■ Accessories                 (Order   Separately)

Lock Key                                                                             Y92S-38

Mounting Track                               50 cm (l) x 7.3 mm (t)                  PFP-50N

                                             1 m (l) x 7.3 mm (t)                    PFP-100N

                                             1 m (l) x 16 mm (t)                     PFP-100N2

End Plate                                                                            PFP-M

Spacer                                                                               PEP-S

                   http://www.ia.omron.com/                          (c)Copyright OMRON Corporation 2007   All Rights Reserved.  27
                                                                                                                                         H3DS-X

Specifications

■ General

                Item                                                                                H3DS-X

Operating mode                         ON-delay

Operating/Reset method                 Time-limit operation/self-resetting

Output type                            SCR output

External connections                   Screw terminal, Screw-Less Clamp

Terminal block                         Screw terminal type:             Clamps two 2.5-mm2 max. bar terminals         without  sleeves.

                                       Screw-Less Clamp type:           Clamps two 1.5-mm2 max. bar terminals         without  sleeves.

Terminal screw tightening      torque  0.98 N·m max.

Mounting method                        DIN track mounting (see note)

Attachment                             Nameplate label

Approved standards                     UL508, CSA C22.2 No.14

                                       Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

Note: Can be mounted to 35-mm DIN      Track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges

       Time  scale display                       Time range

0.1 s                                0.1 to 1.2 s

1s                                   1 to 12 s

0.1 m                                0.1 to 1.2 min

1m                                   1 to 12 min

0.1 h                                0.1 to 1.2 h

1h                                   1 to 12 h

10 h                                 10 to 120 h

Note:  When  the time setting  dial  is set to “0” for any time scale,  the  output  will  operate  instantaneously.

■ Ratings

Rated supply voltage (see note)                        24 to 230 VAC/VDC (50/60 Hz)

Operating voltage range                                85% to 110% of rated supply voltage

Power reset                                            Minimum power-off time: 0.1 s

Reset voltage                                          1.0 VAC/VDC max.

Reset current                                          5 mA max.

Power consumption                                      5 mA max.

Control output                                         SCR output:5 mA to 0.7 A

Ambient temperature                                    Operating: –10°C to 55°C (with no icing)

                                                       Storage:         –25°C to 65°C (with no icing)

Ambient humidity                                       Operating: 35% to 85%

Note: The ripple in DC power supply    must  be    5%  max.

                      http://www.ia.omron.com/                                             (c)Copyright OMRON Corporation 2007           All Rights Reserved.  28
                                                                                                                                        H3DS-X

■ Characteristics

Accuracy of operating time       ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)

Setting error                    ±10% ± 50 ms max. of FS

Reset time                       0.1 s max.

Influence of voltage             ±0.5% max. of FS (±0.5%±10 ms max. at 1.2-s range)

Influence of temperature         ±5% max. of FS (±5%±10 ms max. at 1.2-s range)

Insulation resistance            100 MΩ min. at 500 VDC

Dielectric strength              Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min

Impulse withstand voltage        3 kV (between power supply terminals)

                                 4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)

Noise immunity                   Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV (between power

                                 supply terminals)

Static immunity                  Malfunction: 4 kV

                                 Destruction: 8 kV

Vibration resistance             Malfunction: 0.5-mm single amplitude at 10 to 55 Hz

                                 Destruction: 0.75-mm single amplitude at 10 to 55 Hz

Shock resistance                 Malfunction: 200 m/s2, 3 times each in 6 directions

                                 Destruction: 300 m/s2, 3 times each in 6 directions

EMC                              (EMI)                                  EN61812-1

                                 Emission Enclosure:                    EN55011 Group 1 class B

                                 Emission AC Mains:                     EN55011 Group 1 class B

                                 Harmonic Current:                      EN61000-3-2

                                 Voltage Fluctuation and Flickering:    EN61000-3-3

                                 (EMS)                                  EN61812-1

                                 Immunity ESD:                          EN61000-4-2:    6 kV contact discharge (level 3)

                                                                                        8 kV air discharge (level 3)

                                 Immunity RF-interference from AM       Radio Waves:

                                                                        EN61000-4-3:    10 V/m (80 MHz to 1 GHz) (level 3)

                                 Immunity Burst:                        EN61000-4-4:    2 kV power port and output port (level 3)

                                                                                        1 kV control port with capacitive clamp (level  3)

                                 Immunity Surge:                        EN61000-4-5:    2 kV common mode (level 3)

                                                                                        1 kV differential mode (level 3)

Case color                       Light gray (5Y7/1)

Degree of protection             IP30 (IP20 for terminal block)

Weight                           Approx. 70 g

Connections

■ Block Diagram

                                                          Zero setting         Time scale/                Indicator

                                                          detection            unit selectors             circuit

                                                          circuit

                          AC (DC)  Power supply           Oscillation          Counting                   Output

                          input    circuit                circuit              circuit                    circuit

■ I/O    Functions

Inputs                                      ---

Outputs                Control output       Outputs  are  turned ON when  the  preset value is  reached.

                 http://www.ia.omron.com/                                             (c)Copyright OMRON Corporation 2007   All Rights Reserved.  29
                                                                                                                             H3DS-X

■ Terminal Arrangement

                                                     H3DS-XLC                  H3DS-XL

                                                     A1

                                                                               A1

                                                                                   A2

                                                         A2

Note: DC supply voltage does not require the designation of polarity.

Operation

■ Basic Operation

Setting of Selector                                                                Locking/Unlocking of Selectors and

The  selectors  can  be  turned      clockwise  and  counterclockwise      to      Time Setting Dial

select the desired time scale, or operating mode.

Each selector has a snap mechanism that secures the selector at a                  The time setting dial and time scale selector can be locked using the

given position. Set the selector at a position at which it is secured. Do          Y92S-38 Lock Key, a special pen type tool that is sold separately. To

not set it midway between two securing positions or a malfunction                  lock the dial or selectors, insert the Lock Key in the keyhole to the

could result from improper setting.                                                lower right of the dial or selector and turn it clockwise until the dial or

                                                                                   selector is completely covered with the red cover. To unlock, turn the

Selection of Time Scale                                                            Lock Key in the opposite direction.

The time scale is selected by turning the time scale selector. The

time scales will appear in the following order in the time scale display

window on the left of the selector:

1 s, 0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m, 0.1 m.

Note: The time scale “1h” appears twice. Both instances indicate ex-

     actly the same time scale.

                                                                                                                             Key hole

     Time scale display

     window and selector

                     http://www.ia.omron.com/                                           (c)Copyright OMRON Corporation 2007  All Rights Reserved.               30
                                                                                                                                  H3DS-X

■ Timing Charts

                                    Rt  0.1  s min.

Power

(A1 and A2)

Output

                 ON

Indicator

                 OFF

                      Set time               Rt: Resetting  time

Nomenclature

H3DS-XL@                                                                           H3DS-XLC

                                                                                                          Wire connection  holes

Set time window                                      Time setting dial (set time)

                                                     Lock for time setting dial

Time scale display window and                                                                             Release holes

selector (select one from 1 s,                       Lock for time scale selector

0.1 s, 1 h, 0.1 h, 10 h, 1 h, 1 m,

and 0.1 m)

                                    H3DS-XL

                                        A2

                                                     Power-ON indicator (green)    A2

                                                     (Lit while the power is ON.)

                                                                                                          Wire connection  holes

                                    (Front View)

                                                                                   (Front View)

                                                                  Attach the enclosed label here as a nameplate.

                                                                  (The label is attached to the Timer's DIN Track

                                                                  hook section at the time of shipment.)

                      http://www.ia.omron.com/                                     (c)Copyright OMRON Corporation 2007            All Rights Reserved.  31
                                                                                                                            H3DS-X

Dimensions

H3DS-XL

                                                    Surface color:  Light  gray  5Y7/1  (OMRON)

H3DS-XLC

                                    17.5            73

                                          45                                     80

                                                        44

                                                    68

          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

            In the interest of product improvement, specifications are subject to change without notice.

          http://www.ia.omron.com/                  (c)Copyright OMRON Corporation 2007                                All  Rights Reserved.  32
                                                                                                                 H3DS-@LC

Installation of Screw-Less                                       Clamp      Models

■ Tools

A flat-blade screwdriver should be used to mount the cables.

Applicable Screwdriver

● Flat-blade, Parallel-tip, 2.5 mm diameter

Examples:  FACOM AEF.2.5 × 75E

           VESSEL No. 9900-(-)2.5 × 75

           WAGO 210-119

           WIHA 260/2.5 × 40

■ Applicable Wires

Applicable Wire Sizes

0.2 to 1.5 mm2, AWG24 to AWG16

Applicable Wire Type

Solid wires, stranded wires, flexible wires, or wires with ferules can

be used.

(See note 1) < 1.8 ≤ Diameter D (mm) ≤ 3.0 (see note 2)

Conductor diameter d (mm) or length of sides a and b (mm) ≤ 1.6

           Wires with Ferules

Note:  1.  If the overall diameter of the wire is less than 1.8 mm, do not

           insert the wire past the conductor. Refer to the following di-

           agrams.

           OK                                NG

       2.  If the overall diameter of the wire is over 2.8 mm, it will be

           difficult to use double wiring.

                    http://www.ia.omron.com/                                (c)Copyright OMRON Corporation 2007  All Rights Reserved.  33
                                                                                                                                         H3DS-@LC

■ Wiring

Use wires of the applicable sizes specified above. The length of the exposed conductor should be 6 to 7 mm.

                                        6 to 7 mm

    Fig. 1 Exposed Conductor Length

Use the following wiring procedure.

1.  Insert the specified screwdriver into the release hole located     beside  the  wire connection  hole  where  the  wire  is  to  be  inserted.

                                                      A

    Wire

    connection

    holes

    Release

    holes

                                                      A

    Fig. 2 Wire  Connection          Holes and Release Holes

                                        Wire connection hole

                                        Release hole

                                                                                         Insert

                                                               Screwdriver

    Fig. 3 Section A-A of Fig. 2

2.  Insert the exposed conductor  into  the  wire  connection  hole.

                                                               Insert

3.  Pull out the screwdriver.

                                                               Insert

                                                                               Pull out

                 http://www.ia.omron.com/                                                        (c)Copyright OMRON Corporation 2007     All Rights Reserved.  34
                                                               H3DS-@LC

■ Precautions

Always insert the screwdriver straight into the hole, never at an angle. The clamp spring may be deformed if the screwdriver is not straight.

Do not move the screwdriver side to side in the clamp hole. The clamp spring may be deformed if the screwdriver is moved sideways.

http://www.ia.omron.com/  (c)Copyright OMRON Corporation 2007  All Rights Reserved.                                                            35
                                                                                                                                                           H3DS

Accessories (Order Separately)

Note: All units are in millimeters unless otherwise indicated.

■ Dimensions

Lock Key

Y92S-38

                       100                             6.4

Mounting Track

PFP-100N, PFP-50N                                                             PFP-100N2

                                                                                                                                                  16

                                               7.3±0.15

4.5                                                                           4.5

                                                       35±0.3       27±0.15                                                   35±0.3    27  24        29.2

     15  25      25               25       25                       1               15  25      25         25         25  15                1         1.5

             10      1,000 (500)      10       15 (5)                                       10      1,000         10

                     (see note)                (see note)

     Note: The values shown in        parentheses are for          the

             PFP-50N.

End Plate                                                                     Spacer

PFP-M                                                                         PFP-S

                                                                                                                                    16

                                                               10                                                     5             12

                                                               6.2      1.8

                                                               1

                                 50                                     35.5  35.5                                                          34.8

                                                                   1.8                                                        44.3

                                     11.5                      1.3

                                           10  M4 x 8          4.8

                                               pan head                                                                             16.5

                                               screw

                       http://www.ia.omron.com/                                                     (c)Copyright  OMRON Corporation 2007        All Rights Reserved.  36
                                                                                                                                                                          H3DS

Safety Precautions

■ Changing of Setting

                                         !CAUTION                                           Switching Current vs. Ambient

Do not change the time scale or operating mode, while the Timer is in                       Temperature

operation or malfunction could result.                                                      (When Mounting Two or More H3DS

■ Power Supplies                                                                            Units Side-by-Side)

The H3DS Series is provided with a transformerless power supply                             • H3DS-ML@/-SL@/-AL-@

system. An electric shock may be received if the input terminal is

touched while power is being supplied.                                                                                   70

Use the bar terminal for wiring the H3DS. Using a stranded-wire ter-                           Ambient temperature (°C)

minal may cause a short-circuit due to a stray wire entering into the                                                    60                                        Mounting clearance:

Timer.                                                                                                                                                             5 mm

Both AC and DC power supplies can be connected to the power                                                                                                               Maximum range of

input terminals without regarding polarity.                                                                                                                               operating ambient

                                                                                                                         50                                               temperature

With the H3DS only, a DC power supply must be connected to the

power input terminals as designated according to the polarity of the                                                     40                                        Mounting clearance:

terminals.                                                                                                                                                         0 mm

A DC power supply can be connected if its ripple factor is 20% or                                                        30

less and the mean voltage is within the rated operating voltage range

of the Timer.

Make sure that the voltage is applied within the specified range, oth-

erwise the internal elements of the Timer may be damaged.                                                                    0  1       2  3  4               5    Load current (A)

Connect the power supply voltage through a relay or switch in such a                        •  H3DS-FL@/-GL@

way that the voltage reaches a fixed value at once or the Timer may

not be reset or a timer error could result.

Be sure that the capacity of the power supply is large enough, other-                                                    70

wise the Timer may not start due to inrush current (approx. 3 A) that                          Ambient temperature (°C)                                            Mounting clearance:

may flow for an instant when the Timer is turned on.                                                                     60                                        10 mm

For the power supply of an input device of the H3DS-ML@, use an                                                                                                           Maximum range of

isolating transformer, of which the primary and secondary windings                                                                                                        operating ambient

are mutually isolated and the secondary winding is not grounded.                                                         50                                               temperature

                                                                                                                                                                   Mounting clearance:

                                                                                                                         40                                        5 mm

                                         A1                                                                                                                        Mounting clearance:

                                                                                                                                                                   0 mm

               B1                                                                                                        30

                      H3DS-ML@                        Power supply

               Start

               input

                                                                                                                             0  1       2  3  4               5    Load current (A)

                                         A2

                      Rectifier circuit                                                     ■ Input/Output

            Circuit

                                                                                            Relationship between Input and Power

                                             Isolation transformer is required.             Supply Circuits (H3DS-ML@)

■ Installation

If the load current is continuously being supplied to the Timer for a

long period of time, be sure to provide the mounting clearance as                                                                             B1                   A1

shown in the figure below. If used under the conditions other than                                                              AC/DC

those specified below (except for the H3DS-XL@), the life of internal                                                           power      Input circuit  Power supply

components may be shortened due to an excessive rise in the inter-                                                              supply                    circuit

nal temperature.

                                                                                                                                                          A2

               H3DS                          H3DS     H3DS                                  Since the input circuit and the power supply circuit are configured

                                                                                            independently, the input circuit can be turned on or off irrespective of

                                                                                            the on/off state of the power supply.

                                                                                            It must be noted that a voltage equivalent to the power supply voltage

                                                                                 DIN track  is applied to the input circuit.

                                                                                            When connecting a relay or a transistor as an external signal input

                      t                            t                                        device, pay attention to the following points to prevent short-circuiting

                                                                                            due to a sneak current to the transformerless power supply.

                                             t: Mounting clearance (mm)

                      http://www.ia.omron.com/                                                                           (c)Copyright OMRON Corporation 2007       All Rights Reserved.      37
                                                                                                                                               H3DS

If a relay or transistor is connected to two or more Timers, the input  ■ Precautions for EN61812-1

terminals of those Timers must be wired properly so that they will not

be different in phase or the terminals will be short-circuited to one          Conformance

another (refer to the figures below).

Contact or transistor for                                               The H3DS as a built-in timer conforms to EN61812-1 provided that

external input signal                                                   the following conditions are satisfied:

                            A1                                          The output section of the H3DS is provided only with basic isolation.

                                                                        To ensure reinforced isolation required by the EN61812-1, provide

Incorrect               B1                        Power supply          supplementary basic isolation on the load side connected to the out-

                            H3DS-ML@                                    put.

                                                                        The H3DS itself is designed according to the following:

                            A2                                          • Overvoltage category III

Short-circuit                                                           • Pollution degree 2

current

                            A1                                          On the above basis:

                        B1                                              Operation parts on the front and bottom: Reinforced isolation

                            H3DS-ML@                                    – With clearance of 5.5 mm and creepage distance of 5.5 mm at

                                                                        230 VAC

                            A2                                          Output: Basic isolation

                                                                        – With  clearance     of  3  mm  and     creepage            distance  of  3  mm   at

Contact or transistor for                                               230 VAC

external input signal

                            A1                                          ■ Environment

                        B1                                              When using the Timer in an area with excess electronic noise, sepa-

Correct                     H3DS-ML@              Power supply

                                                                        rate the Timer, wiring, and the equipment which generates the input

                                                                        signals as far as possible from the noise sources. It is also recom-

                            A2                                          mended to shield the input signal wiring to prevent electronic interfer-

         Short-circuit                                                  ence.

         current

                            A1                                          Organic solvents (such as paint thinner), as well as very acidic or

                                                                        basic solutions can damage the outer casing of the Timer.

                        B1                                              Do not use the Timer in places where it is exposed to dust, corrosive

                            H3DS-ML@                                    gas, or direct sunlight.

                                                                        When storing the Timer, make sure that the ambient temperature

                            A2                                          and humidity are within the rated values. Leave the Timer at room

                                                                        temperature for at least three hours before using the Timer if it has

The H3DS Series is provided with a transformerless power supply         been stored at an ambient temperature of –10°C or below.

system.                                                                 Leaving the Timer with outputs ON at a high temperature for a long

Input Wires                                                             time may hasten the degradation of internal parts (such as electro-

                                                                        lytic  capacitors).  Therefore,  use  the  product           in  combination  with

                                                                        relays and avoid leaving the product as long as more than 1 month

The input wires must be as short as possible. If the floating capacity  with the output turned ON.

of wires exceeds 2,000 pF (approx. 17 m for cables with 120 pF/m),

the operation will be affected. Pay particular attention when using     ■ Others

shielded cables.

                                                                        If the Timer is mounted on a control board, dismount the Timer from

                                                                        the control board or short-circuit the circuitry of the power board

                                                                        before carrying out a voltage withstand test between the electric cir-

                                                                        cuitry and non current-carrying metal part of the Timer, in order to

                                                                        prevent the internal circuitry of the Timer from damage.

                        ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                        To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                       In the interest of product improvement, specifications are subject to change without notice.

                        http://www.ia.omron.com/                                (c)Copyright OMRON Corporation 2007                  All Rights Reserved.      38
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if

specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL

LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR

STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the product.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety

equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

                                                      Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix

or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual

specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent

the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This catalog shall not be copied for sales or promotions without permission.

This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this

catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

                                                                                                                                                             2007. 3

OMRON Corporation                                                             In the interest of product improvement, specifications are subject to change without notice.

Industrial Automation Company

http://www.ia.omron.com/                                                              (c)Copyright OMRON Corporation 2007                        All Rights Reserved.
This datasheet has been downloaded from:

datasheet.eeworld.com.cn

Free Download

Daily Updated Database

100% Free Datasheet Search Site

100% Free IC Replacement Search Site

Convenient Electronic Dictionary

Fast Search System

www.EEworld.com.cn

All Datasheets Cannot Be Modified Without Permission

               Copyright © Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved