datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

H3CRHRLDC100125M

器件型号:H3CRHRLDC100125M
器件类别:机电产品    工业自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Timers Timer Power Off Delay w/Reset

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Timers
系列:
Series:
H3CR
商标:
Brand:
Omron Automation and Safety
产品类型:
Product Type:
Timers
子类别:
Subcategory:
Timers

H3CRHRLDC100125M器件文档内容

   Solid-state Timer

   H3CR

   Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if                                          you        have  any  questions

   or comments. Refer to Warranty and Application Considerations (page 52), and Safety Precautions (page 22, 44, 51).

   DIN 48 ✕ 48-mm Multifunctional Timer Series

   • Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low                • Lloyds/NK approvals.

   Voltage, and EMC Directives.                                         • Six-language instruction manual provided.

   • Approved by UL and CSA.

   ■ Broad Line-up of H3CR Series

                                                          H3CR

   H3CR-A                        H3CR-F                                 H3CR-G                                                                                  H3CR-H

   Multifunctional Timer         Twin Timer                             Star-delta Timer                                                                        Power OFF-delay Timer

   H3CR-A                        H3CR-F                   11-pin model  H3CR-G8L   8-pin model                                                                  H3CR-HRL   11-pin model

   H3CR-AS   11-pin model        H3CR-FN                                H3CR-G8EL                                                                               H3CR-H8L   8-pin model

   H3CR-AP                       H3CR-F8                  8-pin model                                                                                           H3CR-H8RL

   H3CR-A8   8-pin model         H3CR-F8N

   H3CR-A8S

   H3CR-A8E  8-pin with

             instantaneous

             contact output

             model

   Note: H3CR-AS, H3CR-A8S: Transistor output models

                                                          Contents

   Solid-state Timer

            H3CR-A ..........................................................................................................................................   2

            H3CR-F...........................................................................................................................................   26

            H3CR-G ..........................................................................................................................................   34

            H3CR-H ..........................................................................................................................................   42

   Common to ALL Timers

            Operation ........................................................................................................................................  52

            Accessories ....................................................................................................................................    54

            Safety Precautions..........................................................................................................................        58

1
    Solid-state Multi-functional Timers

    H3CR-A

Multiple Operating Modes and Multiple Time

Ranges. DIN 48 x 48-mm Multifunctional

Timer.

• A wide AC/DC power supply range greatly reduces the number

of timer models kept in stock.

• A wide range of applications with multiple operating modes,

eight modes for 11-pin models and five modes for 8-pin models.

• Ecological design with reduced current consumption.

• Easy sequence checking with instantaneous outputs for a zero

set value.

• Length of 75 mm or less when panel-mounted with a P3G-08                            For the most recent information on models that have been  certified for

Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC)                                     safety standards, refer to your OMRON website.

• PNP input models available.

• Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE

Marking.

Model Number Structure

■ Model Number Legend

Note: This model number legend includes combinations that are not available.  Before  ordering, please check the List of Models on page         3 for avail-

        ability.

H3CR-A@ @ @ - @ @

                  1  2  3  4   5

1.  Number of Pins

    None: 11-pin models

    8:      8-pin models

2.  Input Type for 11-pin Models

    None: No-voltage input (NPN type)

    P:      Voltage input (PNP type)

3.  Output

    None: Relay output (DPDT)

    S:      Transistor output (NPN/PNP universal use)

    E:      Relay output (SPDT) with instantaneous relay output (SPDT)

4.  Suffix

    301:    Double time scale (range) models (0.1 s to 600 h)

5.  Supply Voltage

    100-240AC/100-125DC: 100 to 240 VAC/100 to 125 VDC

    24-48AC/12-48DC:       24 to 48 VAC/12 to 48 VDC

    24-48AC/DC:            24 to 48 VAC/VDC (Only for H3CR-A8E)

                                                                                                                                                               2
   H3CR-A

   Ordering Information

   ■ List of Models

   Note:  1.   Specify both the model number and supply voltage when ordering.

               Example: H3CR-A 100-240AC/100-125DC

                                                       Supply voltage

          2.   The operating modes are as follows

               A:   ON-delay                       D: Signal OFF-delay

               B:   Flicker OFF start              E: Interval

               B2:  Flicker ON start               G: Signal ON/OFF-delay

               C:   Signal ON/OFF-delay            J:  One-shot

   11-pin Models

            Output                     Supply voltage                  Input type    Time range       Operating mode            Model

                                                                                                      (See note 2)              (See note 1.)

   Contact                 100 to 240 VAC (50/60 Hz)/            No-voltage input    0.05 s to 300 h  Eight multi-modes: A, B,  H3CR-A

                           100 to 125 VDC                                                             B2, C, D, E, G, J

                           24 to 48 VAC (50/60 Hz)/

                           12 to 48 VDC

                           100 to 240 VAC (50/60 Hz)/            Voltage input                        Eight multi-modes: A, B,  H3CR-AP

                           100 to 125 VDC                                                             B2, C, D, E, G, J

                           24 to 48 VAC (50/60 Hz)/

                           12 to 48 VDC

                           100 to 240 VAC (50/60 Hz)/            No-voltage input    0.1 s to 600 h                             H3CR-A-301

                           100 to 125 VDC

                           24 to 48 VAC (50/60 Hz)/

                           12 to 48 VDC

   Transistor              24 to 48 VAC (50/60 Hz)/                                  0.05 s to 300 h                            H3CR-AS

   (Photocoupler)          12 to 48 VDC

   8-pin Models

            Output                     Supply voltage                  Input type    Time range       Operating mode            Model

                                                                                                      (See note 2)              (See note 1.)

   Contact                 100 to 240 VAC (50/60 Hz)/            No-input available  0.05 s to 300 h  Five multi-modes: A, B,   H3CR-A8

                           100 to 125 VDC                                                             B2, E, J

                           24 to 48 VAC (50/60 Hz)/                                                   (Power supply start)

                           12 to 48 VDC

                           100 to 240 VAC (50/60 Hz)/                                0.1 s to 600 h                             H3CR-A8-301

                           100 to 125 VDC

                           24 to 48 VAC (50/60 Hz)/

                           12 to 48 VDC

   Transistor              24 to 48 VAC (50/60 Hz)/                                  0.05 s to 300 h                            H3CR-A8S

   (Photocoupler)          12 to 48 VDC

   Time-limit contact and  100 to 240 VAC (50/60 Hz)/                                                                           H3CR-A8E

   instantaneous contact   100 to 125 VDC

                           24 to 48 VAC/VDC (50/60 Hz)

3
                                                                                                                                H3CR-A

■ Accessories (Order Separately)

Adapter, Protective Cover, Hold down Clip, Setting Ring and Panel Cover

                      Name/specifications                                            Models

Flush Mounting Adapter                                       Y92F-30

                                                             Y92F-73 *1

                                                             Y92F-74 *1

Protective Cover                                             Y92A-48B *2

Hold-down Clip (Sold in sets of  For PF085A Socket           Y92H-8

two)                             For PL08 or PL11 Sockets    Y92H-7

Setting Ring A                                               Y92S-27 *3

Setting Ring B and C                                         Y92S-28 *3

Panel Cover                      Light gray (5Y7/1)          Y92P-48GL *4

                                 Black (N1.5)                Y92P-48GB *4

*1  The Y92A-48B Protective Cover and the Y92P-48G@ Panel Cover can not be used at the same time with the Y92F-73/-74 Flush Mounting Adapter.

*2  The Y92A-48B Protective Cover is made from hard plastic. Remove the Protective Cover to change to set value.    The Y92F-73/-74 Flush

    Mounting Adapter and the Y92P-48G@ Panel Cover cannot be used at the same time with Y92A-48B Protective Cover.

*3  The Y92S-27/-28 Setting Ring cannot be used alone. It must be used together with the Y92P-48G@ Panel Cover.

*4  The Y92A-48B Protective Cover and the Y92F-73/-74 Flush Mounting Adapter cannot be used at the same time with the Y92P-48G@ Panel Cover.

Sockets

             Timer                                                    Round Sockets

                Pin                              Connection                Terminal                                            Models

11-pin                           Front Connecting            DIN track mounting      P2CF-11

                                                             DIN track mounting      P2CF-11-E

                                                             (Finger-safe type)

                                 Back Connecting             Screw terminal          P3GA-11

                                                             Solder terminal         PL11

                                                             Wrapping terminal       PL11-Q

                                                             PCB terminal            PLE11-0

8-pin                            Front Connecting            DIN track mounting      P2CF-08

                                                             DIN track mounting      P2CF-08-E

                                                             (Finger-safe type)

                                                             DIN track mounting      PF085A

                                 Back Connecting             Screw terminal          P3G-08

                                                             Solder terminal         PL08

                                                             Wrapping terminal       PL08-Q

                                                             PCB terminal            PLE08-0

Note: 1.   The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.

       2.  The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection.

       3.  For details, refer to your OMRON website.

Terminal Cover

                            Application                                       Model                                 Remarks

For back connecting socket                                   Y92A-48G                                             For P3G-08 and P3GA-11

Note: For details, refer to your OMRON website.

                                                                                                                                               4
   H3CR-A

   Specifications

   ■ General

               Item                H3CR-A/-AS/-A-301             H3CR-AP                H3CR-A8/-A8S/-A8-301                     H3CR-A8E

   Operating mode             A:    ON-delay                                            A:   ON-delay (power supply start)

                              B:    Flicker OFF start                                   B:   Flicker OFF start (power supply start)

                              B2: Flicker ON start                                      B2: Flicker ON start (power supply start)

                              C:    Signal ON/OFF-delay                                 E:   Interval (power supply start)

                              D:    Signal OFF-delay                                    J:   One-shot (power supply start)

                              E:    Interval

                              G:    Signal ON/OFF-delay

                              J:    One-shot

   Pin type                   11-pin                                                    8-pin

   Input type                 No-voltage input             Voltage input                ---

   Time-limit output type     H3CR-A/-A8/-AP/-A-301/-A8-301: Relay output (DPDT)                                                 Relay output (SPDT)

                              H3CR-AS/-A8S:     Transistor output (NPN/PNP universal)*

   Instantaneous output type  ---                                                                                                Relay output (SPDT)

   Mounting method            DIN track mounting, surface mounting, and flush mounting

   Approved standards         UL508, CSA C22.2 No.14, NK, Lloyds, CCC

                              Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.

                              Output category according to EN60947-5-1 for Timers with Contact Outputs.

                              Output category according to EN60947-5-2 for Timers with Transistor Outputs.

   * The internal circuits are optically isolated from the output. This enables universal application as NPN or PNP transistor.

   For details, refer to your OMRON website.

   ■ Time Ranges

   Note: When the time setting knob is turned below “0” until the point where the time setting knob stops, the output will operate instantaneously    at

   all time range settings.

   For details, refer to your OMRON website.

   Standard (0.05-s to 300-h) Models

            Time unit              s (sec)      10 s (10 sec)   min (min)        10 min (10 min)          h (hrs)              10 h (10 hrs)

   Full scale  1.2         0.05 to 1.2          1.2 to 12        0.12 to 1.2      1.2 to 12         0.12 to 1.2                  1.2 to 12

   setting     3           0.3 to 3             3 to 30          0.3 to 3         3 to 30           0.3 to 3                     3 to 30

               12          1.2 to 12            12 to 120        1.2 to 12        12 to 120         1.2 to 12                    12 to 120

               30          3 to 30              30 to 300        3 to 30          30 to 300         3 to 30                      30 to 300

   Double (0.1-s           to 600-h)        Models

            Time unit              s (sec)      10 s (10  sec)  min (min)        10 min (10 min)          h (hrs)              10 h (10 hrs)

   Full scale  2.4         0.1 to 2.4           2.4 to 24        0.24 to 2.4      2.4 to 24         0.24 to 2.4                  2.4 to 24

   setting     6           0.6 to 6             6 to 60          0.6 to 6         6 to 60           0.6 to 6                     6 to 60

               24          2.4 to 24            24 to 240        2.4 to 24        24 to 240         2.4 to 24                    24 to 240

               60          6 to 60              60 to 600        6 to 60          60 to 600         6 to 60                      60 to 600

5
                                                                                                                                                              H3CR-A

■ Ratings

Rated supply voltage (See  notes  1,  2,  and  5.)  100 to 240 VAC (50/60 Hz)/100 to 125 VDC, 24 to 48 VAC (50/60 Hz)/12 to 48 VDC (24 to 48 VAC/VDC for H3CR-A8E)

                                                    (See note 3.)

Operating voltage range                             85% to 110% of rated supply voltage (90% to 110% at 12 VDC)

Power reset                                         Minimum power-opening time: 0.1 s

Input (See note 6.)                                 No-voltage Input

                                                    ON impedance:           1 kΩ max.

                                                    ON residual voltage:    1 V max.

                                                    OFF impedance:          100 kΩ min.

                                                    Voltage Input

                                                    Max. permissible capacitance between inputs lines (terminals        6  and  7):  1,200  pF

                                                    Load connectable in parallel with inputs (terminals 6 and 7).

                                                    •  100 to 240 VAC/100 to 125 VDC

                                                       High (logic) level:  85 to 264 VAC/85 to 137.5 VDC

                                                       Low (logic) level:   0 to 10 VAC/0 to 10 VDC

                                                    •  24 to 48 VAC/12 to 48 VDC

                                                       High (logic) level:  20.4 to 52.8 VAC/10.8 to 52.8 VDC

                                                       Low (logic) level:   0 to 2.4 VAC/0 to 1.2 VDC

Power consumption                                   H3CR-A/-A8

                                                    •  100 to 240 VAC/100 to 125 VDC

                                                       (When at 240 VAC, 60 Hz)

                                                                   Relay ON: approx. 2.0 VA (1.6 W)                        Relay OFF: approx. 1.3 VA (1.1 W)

                                                    •  24 to 48 VAC/12 to 48 VDC

                                                       (When at 24 VDC)

                                                                   Relay ON: approx. 0.8 W                                 Relay OFF: approx. 0.2 W

                                                    H3CR-AP (See note 3)

                                                    •  100 to 240 VAC/100 to 125 VDC

                                                       (When at 240 VAC, 60 Hz)

                                                                   Relay ON: approx. 2.5 VA (2.2 W) (See   note    4.)     Relay OFF: approx. 1.8 VA (1.7 W) (See note 4.)

                                                    •  24 to 48 VAC/12 to 48 VDC

                                                       (When at 24 VDC)

                                                                   Relay ON: approx. 0.9 W (See note 4.)                   Relay OFF: approx. 0.3 W (See note 4.)

                                                    H3CR-A8E

                                                    •  100 to 240 VAC/100 to 125 VDC

                                                       (When at 240 VAC, 60 Hz)

                                                                   Relay ON/OFF: approx. 2 VA (0.9 W)

                                                    •  24 to 48 VAC/VDC

                                                       (When at 24 VDC)

                                                                   Relay ON/OFF: approx. 0.9 W

                                                    H3CR-AS/-A8S

                                                    •  24 to 48 VAC/12 to 48 VDC

                                                       (When at 24 VDC)

                                                                   Output ON: 0.3 W Output OFF: 0.2 W

Control outputs                                     •  Models with Contact Outputs

                                                       H3CR-A/-A8/-AP

                                                       5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1)

                                                       Minimum applied load: 10mA at 5 VDC (failure level: P reference value)

                                                       Contact materials: Ag-alloy

                                                       H3CR-A8E

                                                       5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1)

                                                       Minimum applied load: 10mA at 5 VDC (failure level: P reference value)

                                                       Contact materials: AgSnIn

                                                    •  Transistor output: Open collector(NPN/PNP)

                                                       H3CR-AS/-A8S

                                                       100 mA max at 30 VDC max., residual voltage: 2 VDC max.

Note: 1.  DC ripple rate: 20% max. (A single-phase, full-wave-rectification power supply can be used).

2.        Do not use an inverter output as the power supply. Refer to your OMRON website for details.

3.        Models with 24-to-48-VAC or 12-to-48-VDC power supply have inrush current. Caution is thus required when turning ON and OFF power

          to the Timer with a non-contact output from a device such as a sensor. (Models with an inrush current of approximately 50 mA and a 24-

          VDC power supply are available (the H3CR-A-302 and H3CR-A8-302).)

          For details, consult your OMRON sales representative.

4.        The values are for when the terminals 2 and 7 and terminals 10 and 6 are short-circuited, and include the consumption current of the

          input circuit.

5.        Refer to your OMRON website when using the Timer together with a 2-wire AC proximity sensor.

6.        For details, see Input Connections: No-voltage Input Signal Levels on page 11, and Input Connections: Voltage Input Signal Levels on

          page 12.

                                                                                                                                                                            6
   H3CR-A

   ■ Characteristics

   Accuracy of operating                           ±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s)

   time

   Setting error                                   ±5% FS ±50 ms (See note 1)

   Reset time                                      Min. power-opening time: 0.1 s max.

                                                   Min. pulse width:                   0.05 s (H3CR-A/-AS)

   Reset voltage                                   10% max. of rated supply voltage

   Influence of voltage                            ±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s)

   Influence of temperature                        ±1% FS max. (±1%±10 ms max. in a range of 1.2 s or 3 s)

   Insulation resistance                           100 MΩ min. (at 500 VDC)

   Dielectric strength                             2,000 VAC (1,000 VAC for H3CR-A@S), 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-

                                                   current-carrying metal parts)

                                                   2,000 VAC (1,000 VAC for H3CR-A@S), 50/60 Hz for 1 min (between control output terminals and operating circuit)

                                                   2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)

                                                   1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)

                                                   2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and operation circuit) for H3CR-AP

   Impulse withstand                               5 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48 VAC/12 to 48 VDC

   voltage                                         5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC/100 to

                                                   125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and 24 to 48 VAC/VDC

   Noise immunity                                  ±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals), square-wave noise by noise

                                                   simulator (pulse width: 100 ns/1 μs, 1-ns rise)

   Static immunity                                 Malfunction:            8 kV

                                                   Destruction:            15 kV

   Vibration resistance                            Destruction:            10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each

                                                   Malfunction:            10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each

   Shock resistance                                Destruction:            1,000 m/s2 3 times each in 6 directions

                                                   Malfunction:            100 m/s2 3 times each in 6 directions

   Ambient temperature                             Operating:              −10°C to 55°C (with no icing)

                                                   Storage:                −25°C to 65°C (with no icing)

   Ambient humidity                                Operating:              35% to 85%

   Life expectancy                                 Mechanical:             20,000,000 operations min. (under no load at 1,800 operations/h)

                                                   Electrical:             100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note 2)

   EMC                                             (EMI)                                     EN61812-1

                                                   Emission Enclosure:                       EN55011 Group 1 class A

                                                   Emission AC Mains:                        EN55011 Group 1 class A

                                                   (EMS)                                     EN61812-1

                                                   Immunity ESD:                             IEC61000-4-2

                                                   Immunity RF-interference:                 IEC61000-4-3

                                                   Immunity Burst:                           IEC61000-4-4

                                                   Immunity Surge:                           IEC61000-4-5

                                                   Immunity Conducted Disturbance:           IEC61000-4-6

                                                   Immunity Voltage Dip/Interruption:        IEC61000-4-11

   Case color                                      Light gray (Munsell 5Y7/1)

   Degree of protection                            IP40 (panel surface)

   Weight                                          Approx. 90 g

   Note: 1.                          The value is ±5% FS +100 ms to −0 ms max. when the C, D, or G mode signal of the H3CR-AP is OFF.

                                 2.  Refer to the Life-test Curve (Reference).

                                 3.  Contact output only.

   ■ Life-test Curve (Reference)

   Switching operations (x 103)  10,000

                                 5,000

                                                                                 Reference:  A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1) and

                                 1,000                                                       a maximum current of 0.1A can be switched at 125V DC and L/R = 7ms.

                                     500        30 VDC L/R = 7 ms                            In both cases, a life of 100,000 operations can be expected.

                                                           250 VAC/30                        The minimum applicable load is 10 mA at 5 VDC (failure level: P).
                                                           VDC (cosφ = 1)

                                     100

                                             250 VAC (cosφ = 0.4)

                                          0  1  2  3       4       5

                                                Load current (A)

7
                                                                                                     H3CR-A

Connections

■ Block Diagrams

H3CR-A/-AS/-A-301

                   AC (DC) input               Zero setting    Time range/     Operating

                                               detection       unit selectors  mode selector

                                               circuit

                   Power supply                Oscillation     Counting        Output circuit

                   circuit                     circuit         circuit

                   Reset input, start  input,  and gate input  Input circuit   Indicator

                                                                               circuit

                                                                               Power-ON   Output-ON

                                                                               indicator  indicator

H3CR-AP

                   AC (DC) input               Zero setting    Time range/     Operating

                                               detection       unit selectors  mode selector

                                               circuit

                   Power supply                Oscillation     Counting        Output circuit

                   circuit                     circuit         circuit

                   Start                                       Input circuit   Indicator

                                                                               circuit

                                                                               Power-ON   Output-ON

                                                                               indicator  indicator

                                                                                                             8
   H3CR-A

   H3CR-A8/-A8S/A8-301

                           AC (DC) input          Zero setting               Time range/                 Operating

                                                  detection                  unit selectors              mode selector

                                                  circuit

                                    Power supply  Oscillation                Counting                    Output circuit

                                    circuit       circuit                    circuit

                                                                                                         Indicator

                                                                                                         circuit

                                                                                             Power-ON             Output-ON

                                                                                             indicator            indicator

   H3CR-A8E

                           AC (DC) input          Zero setting               Time range/                 Operating

                                                  detection                  unit selectors              mode selector

                                                  circuit

                                    Power supply  Oscillation                Counting                    Output circuit

                                    circuit       circuit                    circuit

                                                                                                         Indicator

                                                                                                         circuit

                                                                                             Power-ON             Output-ON

                                                                                             indicator            indicator

                                                                                                         Instantaneous

                                                                                                         output circuit

   ■ I/O Functions

   Inputs (for -A/  Start           Starts time-measurement.

   -AS models)      Reset           Interrupts time-measurement and resets time-measurement value. Timing operation is stopped  and  the

                                    control output turns OFF (it is reset).

                    Gate            The timing operation is interrupted while the gate input is active.

   Outputs          Control output  Outputs are turned ON according to designated output mode when preset value is reached.

   Note: H3CR-AP incorporates start input only.

   Models H3CR-A8/-A8E/-A8S/-A8-301 do not have an input function.

9
                                                                                                                                    H3CR-A

■ Terminal Arrangement

Note: 1.         The delayed contact of conventional Timers was indicated as

                 The contact symbol of the H3CR-A is indicated as  because its operating mode is six multi-modes (four multi-modes for the H3CR-A8).

             2.  Do not use an empty terminal on the H3CR-AP/-AS/-A8S as a relay terminal or otherwise.

11-pin Models                                                                 8-pin Models

H3CR-A/-A-301 (Contact Output)                                                H3CR-A8/-A8-301 (Contact Output)

Reset input      Start input  Gate input

                                                                                                         Power supply

                                           Power supply                       H3CR-A8S (Transistor Output)

H3CR-AS (Transistor Output)

Reset input      Start input  Gate input                                                                 Power supply

                                                                              Note: Terminals 1, 3, 4, and 5 are empty.  Terminals  2  and  7  are    the

                                                                              same as for the H3CR-A8.

                                                                              H3CR-A8E (Contact Output)

                                           Power supply

Note: Terminals 1, 3, 4, and 8 are empty. Terminals 2, 5, 6, 7, and 10

             are the same as for the H3CR-A.

H3CR-AP (Contact Output)

                              Start input                                                                Power supply

                                           Power supply

Note: 1.         Terminal 5 is empty.

             2.  Separate power supplies can be used for the Timer and in-

                 puts.

                                                                                                                                                           10
    H3CR-A

    ■ Input Connections

    H3CR-A/-AS/-A-301

    The inputs of the H3CR-A/-AS/-A-301        are  no-voltage  (short-circuit or open)  inputs.

    No-voltage Inputs

    No-contact Input                                Contact     Input                             No-contact Input

    (Connection to NPN open                                                                       (Connection to a voltage

    collector output sensor.)                                                                     output sensor.)

    12 to 24 VDC                                                                                  12 to 24 VDC

    (sensor power supply)                                                                         (sensor power supply)  +

                           +   DC power                                                                                  −     DC power

                           −   supply                                                                                          supply

                              Timer                                    Timer                                                Timer

    Sensor

                                                                                                  Sensor

                               5  Gate                                    5  Gate                                              5  Gate

                               6  Start                                   6  Start                                             6  Start

                               7  Reset                                   7  Reset                                             7  Reset

                           2      Input (0 V)                          2  Input (0 V)                                       2  Input (0 V)

    Operates with transistor ON                     Operates with relay ON                        Operates with transistor ON

    No-voltage Input Signal Levels

    No-contact    1. Short-circuit level

    input         Transistor ON

                  Residual voltage: 1 V max.

                  Impedance when ON: 1 kΩ max.

                  2. Open level

                  Transistor OFF

                  Impedance when OFF: 100 kΩ min.

    Contact       Use contacts which can

    input         adequately switch 0.1 mA at 5 V

11
                                                                                                                                        H3CR-A

H3CR-AP

The start input of the H3CR-AP is voltage input. (Voltage imposition or open)

Voltage Inputs

No-contact Input                          No-contact Input                                 Contact Input

(Connection to PNP open                   (Connection to NPN open

collector output sensor)                  collector output sensor)

12 to 24 VDC                                    12 to 24 VDC

(sensor power supply)                           (sensor power supply)

                       +     DC power                                   +  DC power

Sensor                 −     supply       Sensor                        −  supply

                          Timer                                            Timer                                                Timer

                          10 Power                                         10 Power        AC power supply  DC power supply  10  Power
                                                                               supply (+)
                             supply (+)                                                                                          supply (+)

                          6  Start                                         6   Start                                         6   Start

                          7  Input 0V                                      7   Input 0V                                      7   Input 0V

                          2  Power                                         2   Power                                             Power

                             supply                                            supply (−)                                    2   supply (−)

                             (−)

Operates with PNP transistor ON                 Operates with NPN transistor ON            Operates with relay ON

                                         Note:  The input circuit is isolated from the     Note:            Refer to the signal levels in the

                                                power supply circuit. Thus, an NPN                          following table and be aware of the

                                                transistor can be connected.                                minimum applicable load of the relay.

Note: Before making connections, refer to Safety Precautions (H3CR-@).

Voltage Input Signal Levels

No-contact    1. Transistor ON

input         Residual voltage: 1 V max.

              The voltage between terminals 6 and 7 must be 10.8 VDC min.

              2. Transistor OFF

              Leakage current: 0.01 mA max.

              The voltage between terminals 6 and 7 must be 1.2 VDC max.

Contact       Use contacts that can adequately switch 0.1 mA at each

input         operating voltage.

              The voltage between terminals 6 and 7 with contacts ON or

              OFF must satisfy the specified value.

              Contacts ON

              100-to-240-VAC and 100-to-125-VDC models: 85 to 264 VAC

              or 85 to 137.5 VDC

              24-to-48-VAC and 12-to-48-VDC models: 20.4 to 52.8 VAC or

              10.8 to 52.8 VDC

              Contacts OFF

              100-to-240-VAC and 100-to-125-VDC models: 0 to 10 VAC or

              0 to 10 VDC

              24-to-48-VAC and 12-to-48-VDC models: 0 to 2.4 VAC or 0 to

              1.2 VDC

                                                                                                                                                   12
    H3CR-A

    Operation

    ■ Timing Chart (Refer to page 20 for application examples.)

    H3CR-A/-AS/-AP*/-A-301

    Operating                                                                  Timing chart

         mode

    A: ON-delay                       t                                     t                Basic operation

                  Power

                  Start                                                                      Power

                  Reset                                                                      Start

                                                                                             (See note)                 t

                  Output relay (NC)                                                          Output

                  Output relay (NO)                                                          Note:       Start input is invalid while the

                  (Output indicator)

                  Power indicator                                                                        Timer is in operation.

    B:                                                                                       Basic operation

    Flicker  OFF  Power

    start                                                                                    Power

                  Start

                  Reset                                                                      Start

                  Output relay (NC)                                                          (See note)              t     t           t     t

                  Output relay (NO)                                                          Output

                  (Output indicator)                                                         Note:       Start input is invalid while

                  Power indicator                                                                        the Timer is in operation.

    B2:

    Flicker  ON                                                                              Basic operation

    start         Power

                                                                                             Power

                  Start

                  Reset                                                                      Start

                  Output relay (NC)                                                          (See note)              t        t           t        t

                                                                                             Output

                  Output relay (NO)                                                          Note:       Start input is invalid while              the

                  (Output indicator)

                  Power indicator                                                                        Timer is in operation.

    C:

    Signal ON/                                                                                           Basic operation

    OFF-delay     Power

                                                                                                         Power

                  Start

                  Reset                                                                                  Start             t           t        t       t

                                                                                                         (See note)

                  Output relay (NC)                                                                      Output

                  Output relay (NO)                                                                      Note:             Start input is valid and

                  (Output indicator)

                  Power indicator                                                                                          retriggerable while the Timer

                                                                                                                           is in operation.

    Note: 1.   Allow at least 0.1 s for the Timer reset time if the power supply is reset due to an interruption in the power supply.

           2.  The minimum input pulse width (for start, reset) is 0.05 s.

           3.  The letter "t" in the timing charts indicates the set time, and "t-a" means that the period is less than the set time. (t - a < 1)

           4.  H3CR-AP model incorporates start input only.

           5.  Model H3CR-AS only has operation equivalent to time-limit contact: NO.

           6.  When the setting dial is turned all the way past 0 for instantaneous output, "t" (set time) in the above time chart is 0-sec operation.

13
                                                                                                                                              H3CR-A

Operating                                                             Timing chart

       mode

D:

Signal OFF-                                                                                                            Basic operation

delay            Power

                 Start                                                                                                 Power

                 Reset                                                                                                 Start

             Output relay (NC)                                                                                 (See note)                  t

                                                                                                                       Output

             Output relay (NO)

             (Output indicator)                                                                                Note:      Start input is valid and

             Power indicator                                                                                              retriggerable while the

                                                                                                                          Timer is in operation.

E:                                                                                                             Basic operation

Interval

                 Power                                                                                         Power

                 Start

                                                                                                               Start           t

                 Reset                                                                                  (See note)

             Output relay (NC)                                                                                 Output

             Output relay (NO)                                                                                 Note:   Start input is valid and

             (Output indicator)                                                                                        retriggerable while the

             Power indicator                                                                                           Timer is in operation.

                                                                                                                       (Previous start input

                                                                                                                       will be cancelled.)

G:                                                                                        Basic        operation

Signal ON/

OFF-delay        Power

                 Start                                                                    Power

                 Reset                                                                    Start

                                                                                          (See note)    t         t       t       t

             Output relay (NC)

             Output relay (NO)                                                            Output

             (Output indicator)                                                           Note:         Start input is valid and

             Power indicator                                                                            retriggerable while the Timer

                                                                                                        is in operation.

J:                                                                                                     Basic operation

One-shot         Power

output

                 Start                                                                                 Power

                 Reset                                                                                 Start

             Output relay (NC)                                                            (See note)                   t          1±0.6 s

                                     1±0.6 s                          1±0.6 s                          Output                     (Fixed)

             Output relay (NO)       (Fixed)                          (Fixed)

             (Output indicator)                                                                        Note:      Start input is valid and

             Power indicator                                                                                      retriggerable while the

                                                                                                                  Timer is in operation.

                                                                                                                  (Previous start input will

                                                                                                                  be cancelled.)

Gate Signal  Input  (This        timing chart  indicates  the  gate  input in operating mode A (ON-delay operation).)

             t1                  t2

Power   ON                                                                     Note:  1.  Allow at least 0.1 s for the Timer reset time if the power

        OFF                                                                               supply is reset due to an interruption in the power supply.

                                                                                      2.  The minimum input pulse width (for start, reset) is 0.05 s.

Start   ON                                                                            3.  The letter "t" in the timing charts indicates the set time, and

        OFF                                                                               "t-a" means that the period is less than the set time.

Gate    ON                                                                                (t - a < 1)

        OFF                                                                           4.  In J Mode, there will be only one output even if the start input is

Reset   ON                                                                                longer than the set time.

        OFF                                                                           5.  H3CR-AP model incorporates start input only.

Output  ON                                                                            6.  Model H3CR-AS only has operation equivalent to time-limit

relay   OFF                                                                               contact: NO.

                                                                                      7.  When the setting dial is turned all the way past 0 for

                                                                                          intantaneous output, "t" (set time) in the above time chart is

                                                                                          0-sec operation.

                                                               Note:  The set time is     the sum of t1 and t2.

                                                                      Start and reset     are also both enabled when the gate signal is ON.

                                                                                                                                                               14
    H3CR-A

    H3CR-A8/-A8S/-A8-301

    Operating                                                                  Timing   chart

         mode

    A:

    ON-delay           Power

                                                                                                       Basic operation

                 Output relay

                 (NC)                                                                          Power

                 Output relay                                                                                       t

                 (NO) (output                                                                  Output

                 indicator)

                 Power

                 indicator

    B:                         U                U  UʵB  3U      U  U      U  UʵB

    Flicker OFF

    start              Power                                                                          Basic operation

                 Output relay

                 (NC)                                                                          Power

                 Output relay                                                                                    t           t     t                           t

                 (NO) (output

                 indicator)                                                                    Output

                 Power

                 indicator

    B2:

    Flicker ON

    start              Power                                                                   Basic operation

                 Output relay

                 (NC)                                                                          Power

                 Output relay                                                                                 t           t     t                  t

                 (NO) (output

                 indicator)                                                                    Output

                 Power

                 indicator                                                                                                                                  v

    E:

    Interval           Power

                                                                                                       Basic operation

                 Output relay

                 (NC)                                                                          Power

                 Output relay                                                                                          t

                 (NO) (output

                 indicator)                                                                    Output

                 Power

                 indicator

    J:

    One-shot

    output             Power

                 Output relay                                                                          Basic operation

                 (NC)

                 Output relay      1±0.6         s                             1±0.6 s                Power

                 (NO) (output      (Fixed)                                     (Fixed)

                 indicator)                                                                                               t                        1±0.6 s

                                                                                                      Output                                       (Fixed)

                 Power

                 indicator

    Note: 1.   Allow a timer reset time (Rt) of  0.1 s or longer.

           2.  The letter "t" in the timing charts indicates the set time, and "t-a" means that the period is less than the set time. (t - a < 1)

           3.  Model H3CR-A8S only has operation equivalent to time-limit contact: NO.

           4.  When the setting dial is turned all the way past 0 for intantaneous output, "t" (set time) in the above time chart is 0-sec operation.

           5.  You can use J Mode to use the power supply as the start input.

15
                                                                                                                         H3CR-A

H3CR-A8E

Operating                                                         Timing chart

     mode

A:

ON-delay

                         Power

               Output relay (NC)

               Output relay (NO)                                                        Basic operation

               (output indicator)

               Instantaneous                                                            Power

               output relay (NC)                                                                       t

               Instantaneous

               output relay (NO)                                                        Output

               Power indicator

B:                                 U  U       UʵB  3U  U  U  U  UʵB

Flicker   OFF            Power

start

               Output relay (NC)

               Output relay (NO)                                                        Basic operation

               (output indicator)

               Instantaneous                                                            Power

               output relay (NC)                                                                 t           t     t           t

               Instantaneous

               output relay (NO)                                                        Output

               Power indicator

B2:

Flicker   ON

start                    Power

               Output relay (NC)

                                                                                Basic operation

               Output relay (NO)

               (output indicator)

                                                                                Power

               Instantaneous                                                            t           t           t     t

               output relay (NC)

               Instantaneous                                                    Output

               output relay (NO)

               Power indicator

E:

Interval                 Power

               Output relay (NC)

               Output relay (NO)                                                        Basic operation

               (output indicator)

               Instantaneous

               output relay (NC)                                                        Power

               Instantaneous                                                                           t

               output relay (NO)

                                                                                        Output

               Power indicator

J:

One-shot

output                   Power

               Output relay (NC)

               Output relay (NO)       (Fixed)                        (Fixed)           Basic operation

               (output indicator)

               Instantaneous

               output relay (NC)                                                        Power

               Instantaneous                                                                              t           1±0.6 s

               output relay (NO)                                                        Output                        (Fixed)

               Power indicator

Note: Refer to page 14.

                                                                                                                                  16
    H3CR-A

    Nomenclature

                                      Power indicator (green) (Flashes when Timer

                                      operates; lit when Timer stops operating)    Operating mode display window

                                                                                   Operating mode selector

               Output indicator (orange)                                           Select a mode from:

               (Lit when output)                                                   A, B, B2, C, D, E, G, and J (H3CR-A, -AP, and -AS)

                                                                                   A, B, B2, E and J (H3CR-A8, -A8S, and -A8E)

                                                                                   Scale range display windows

    Time range selector (select one                                                Time unit display window

    from 1.2, 3, 12, and 30 at full

    scale; with the H3CR-A@-301,                                                   Time unit selector (select one from

    select from 2.4, 6, 24, or 60 at                 Time setting                  sec, 10s, min, 10m, hrs, and 10h)

    full scale.)                                     knob (set time)

    Scale range display windows changes as below by

    turning

    the Time range selector clockwise.*

            0     0.2  0.4        0.6     0.8  1.0   1.2

            0     0.5  1          1.5     2    2.5   3

            0     2    4          6       8    10    12

            0     5    10   15           20    25    30

    *       On the H3CR-A@-301 type, the time is twice as long.

17
                                                                                                                                                    H3CR-A

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H3CR-A

H3CR-AP

H3CR-AS                                                                                          15             66.6

H3CR-A-301                                                                                           6   52.3

                                                                48                                                   0.7

                                 48                                                39 dia.                                44.8 × 44.8

                                                                                                                          11 pins

H3CR-A8

H3CR-A8S

H3CR-A8E

H3CR-A8-301                                                                                       15            66.6

                                                                                                      6  52.3

                                                                48                                                   0.7

                                 48                                                39 dia.                                44.8 × 44.8

                                                                                                                          8 pins

Dimensions with Set Ring

Y92S-27/-28 (Order Separately)                                  50                          16.5

                                 50                                                42 dia.

                                                                                   Time Setting         Panel cover

                                                                                   Ring

Dimensions with Front Connecting Socket                                        Dimensions with Back                       Connecting Socket

P2CF-08-@/P2CF-11-@                                                            P3G-08/P3GA-11

                                                                               15                81.5                     15           81.5

                                                                                                 80                                    75

        H3CR-A                   H3CR-A8@                                                H3CR-A                                    H3CR-A8@

        H3CR-A-301               H3CR-A8-301                                             H3CR-A-301                                H3CR-A8-301

100.8*  H3CR-AS     98.5  89.9*  H3CR-A8E                       87.6                     H3CR-AS                                   H3CR-A8E

        H3CR-AP                  H3CR-A8S                                                H3CR-AP                                   H3CR-A8S

                                                                                         +                                         +

                                                                                         Adapter                                   Adapter

                                                                                                  P3GA-11                                   P3G-08

                                                                                   Y92F-30               (When                     Y92F-30   (When

        P2CF-11     2.3*         P2CF-08                        2.3*                                     Y92A-48G                            Y92A-48G

        P2CF-11-E                P2CF-08-E                                                               mounted)                            mounted)

Note: There are no restrictions to the mounting direction.

* These dimensions vary with the kind of DIN track (reference         value).

                                                                                                                                                            18
    H3CR-A

    ■ Accessories (Order Separately)

    Protective Cover                                                    Hold-down Clip

    Y92A-48B                                                            Y92H-8

    To use the Protective Cover with a flush mounting, use the Y92F-30  The Y92H-8 Hold-down Clip is attached to the PF085A socket.

    flush mounting adaptor.

    This Protective Cover cannot be used together with the Y92F-73/-74

    flush mounting adaptor or the panel cover.

                                                                        Y92H-7

                                                                        Y92H-7 Hold-down Clip is attached with screws together with the

                                                                        PL08 socket or the PL11 socket.

19
                                                                                                                                                                    H3CR-A

Application Examples (H3CR-A)

A Mode: ON-delay

ON-delay operation (A mode) is a basic mode.

1. Power-ON Start/Power-OFF Reset                                                         3. Control of Integrated Time with Gate

The Power-ON start/Power-OFF reset operation is a standard                                Signal

operating method.                                                                         Gate signal processing (during input or a temporary timing stop)               is

                                                 t                                        possible with both power start and signal start.

         Power (2 and 10)                                                                                                       t1                t1 + t2: set time

                                                                                                                                              t2

                  Start (2 and 6)                                                                  Power (2 and 10)

                  Reset (2 and 7)                                                                           Start (2 and 6)

Control  output:  NC (8 and 11)                                                                             Gate (2 and 5)

                  NC (1 and 4)

Control  output:  NO (9 and 11)                                                           Control  output:  NC (8 and 11)

                  NO (1 and 3)                                                                              NC (1 and 4)

            Power indicator                                                               Control  output:  NO (9 and 11)

                                              Flashing                                                      NO (1 and 3)

                                                                 Lit                                        Power indicator

                  Externally short-circuited                                                                                        Flashing                        Lit

                                                                                                            Gate signal (The    operation is interrupted with the

                                                                                                            gate signal if the  Timer detects an abnormal signal.)

                                                                                                            Externally

                                                                                                            short-circuited

                                                    Power

                                                    supply

2. Signal Start/Signal Reset                                                                                                         Power

                                                                                                                                     supply

The Signal start/Signal reset operation is useful for remote                 control  of

the Timer.                                                                                B/B2 Mode: Flicker

                                                                                          The flicker operation in the B and B2 modes can be effectively

            Power (2 and 10)                                                              applied to lamp or buzzer (ON and OFF) alarms or the monitoring                of

                                                                                          an intermittent operation with a display.

                  Start (2 and 6)

                                                                                          1. Power-ON Start/Power-OFF Reset (in B

                  Reset (2 and 7)                                                         Mode)

Control  output:  NC (8 and 11)

                  NC (1 and 4)

Control  output:  NO (9 and 11)                                                                    Power (2 and 10)

                  NO (1 and 3)

                  Power indicator                                                                           Start (2 and 6)

                                   Lit           Flashing             Lit                 Control output:   NC (8 and 11)

                                                                                                            NC (1 and 4)

                                   Start signal (remote control  possible)                Control output:   NO (9 and 11)

                                   Reset signal                                                             NO (1 and 3)

                                   (remote control possible)                                                Power indicator

                                                                                                                                     Flashing

                                                                                                   Externally short-circuited

                                                        Power

                                                        supply

                                              (Power continuously supplied)

                                                                                                                                    Power

                                                                                                                                    supply

                                                                                                                                                                             20
    H3CR-A

    2. Signal Start/Signal Reset (in B Mode)                                        2. Signal-ON-OFF Start/Instantaneous

    If there is an abnormal signal, flashing starts. When the abnormal              Operation/Time-limit Reset

    condition is restored, a reset signal stops the display flashing.

                                                                       t  t         Power (2 and 10)

    Power (2 and 10)                                                                                 Start (2 and 6)

                     Start (2 and 6)                                                Control output:  NC (8 and 11)

                                                                                                     NC (1 and 4)

                     Reset (2 and 7)                                                Control output:  NO (9 and 11)

                                                                                                     NO (1 and 3)

    Control output:  NC (8 and 11)

                     NC (1 and 4)                                                                    Power indicator

    Control output:  NO (9 and 11)                                                                                    Lit  Flashing  Lit  Flashing  Lit  Flashing  Lit

                     NO (1 and 3)

                     Power indicator

                                      Lit                 Flashing             Lit

                                                                                                                      Start signal

                     Start signal                                                                                     (The operation starts with the signal ON or       OFF)

                     Reset signal

                                                                                                                                          Power

                                                                                                                                          supply

                                                     Power                                                                 (Power continuously supplied)

                                                     supply

                                           (Power continuously supplied)

    C Mode: Signal ON/OFF-delay                                                     D Mode: Signal OFF-delay

                                                                                    Signal OFF-delay operation (D mode) can be effectively used to keep

    The Signal ON-/OFF-delay operation (C mode) is useful for the                   a load operating for a certain period. For example, this function

    control of distribution of products on a production line into boxes by          enables the cooling fan for a lamp or heater to operate for a certain

    the specified number or time.                                                   period after the lamp or heater is switched OFF.

    1. Power-ON Start/Instantaneous Operation/                                      1. Power-ON Start/Instantaneous Operation/

    Time-limit Reset                                                                Time-limit Reset

    A set of these functions is useful for the operation of a machine for a

    specified period when power is ON.                                              Power (2 and 10)

                                                 t           t                                       Start (2 and 6)

    Power (2 and 10)                                                                Control output:  NC (8 and 11)

                                                                                                     NC (1 and 4)

                     Start (2 and 6)                                                Control output:  NO (9 and 11)

                                                                                                     NO (1 and 3)

    Control output:  NC (8 and 11)                                                                   Power indicator

                     NC (1 and 4)

    Control output:  NO (9 and 11)                                                                                         Lit                 Flashing            Lit

                     NO (1 and 3)

                     Power indicator                                                                                  Start signal (NC to NO)

                                           Flashing  Lit     Flashing     Lit

                     Externally short-circuited

                                                                                                                                          Power

                                                                                                                                          supply

                                                     Power

                                                     supply

21
                                                                                                                                          H3CR-A

2. Signal Start/Instantaneous Operation/                                 2. Signal Start/Instantaneous Operation/

   Time-limit Reset                                                      Time-limit Reset

                                                                         This function is useful for the repetitive control such as the filling of

   Power (2 and 10)                                                      liquid for a specified period after each Signal start input.

                 Start (2 and 6)                                                                           t                 t

Control output:  NC (8 and 11)                                           Power (2 and 10)

                 NC (1 and 4)

Control output:  NO (9 and 11)                                                            Start (2 and 6)

                 NO (1 and 3)

                                                                         Control output:  NC (8 and 11)

                 Power indicator                                                          NC (1 and 4)

                                             Lit          Flashing  Lit  Control output:  NO (9 and 11)

                                                                                          NO (1 and 3)

                                                                                          Power indicator

                 Start signal (NO to NC to NO)                                                             Flashing  Lit     Flashing     Lit

                                                                                          Start signal

                                                  Power

                                                  supply

                                  (Power continuously supplied)                                                      Power

                                                                                                                     supply

E  Mode:         Interval                                                                                  (Power continuously supplied)

1. Power-ON Start/Instantaneous Operation/

   Time-limit Reset

This function is useful for the operation of a machine for a specified

period after power is ON.

                                             t            t

   Power (2 and 10)

                 Start (2 and 6)

Control output:  NC (8 and 11)

                 NC (1 and 4)

Control output:  NO (9 and 11)

                 NO (1 and 3)

                 Power indicator

                                  Flashing        Lit     Flashing  Lit

                 Externally short-circuited

                                                  Power

                                                  supply

                                                                                                                                                    22
    H3CR-A

    Safety Precautions (H3CR-A)

    Refer to Safety Precautions for All Timers.

    Note: The following precautions apply to all H3CR-A models.

    ■ Power Supplies                                                                  ■ Input/Output

    For the power supply of an input device of the H3CR-A use an                      Relationship between Input and Power

    isolating transformer with the primary and secondary windings

    mutually isolated and the secondary winding not grounded.                         Supply Circuits (except for H3CR-A8E)

    Correct                                                                           The H3CR-A (except for H3CR-A8E) uses transformerless power

                                                                                      supply. When connecting a relay or transistor as an external signal

                              H3CR-A                                                  input device, pay attention to the following points to prevent short-

                  G, S, R                                                             circuiting due to a sneak current to the transformerless power supply.

                  5, 6, 7                   10                                        If a relay or transistor is connected to two or more Timers, the input

                              Input                                                   terminals of those Timers must be wired properly so that they will not

                  2           terminal      2                   Power supply

                                                                                      differ in phase, otherwise the terminals will be short-circuited to one

                                                                                      another.

                                                                                      Incorrect                            Short-circuit current

                                                                                                                 H3CR-A

                                                                                      Contact or transistor for

                                                                                      external input signal

                                                 Isolation  transformer is required.                             Input     Power supply

                  Input device                                                                                   terminal

    Incorrect

                  G, S, R     H3CR-A

                  5, 6, 7                        10

                                     Input                                                                       Input

                                terminal                        Power                                            terminal

                           2                     2              supply

                                                                                      Correct

                                                                                                                 H3CR-A

                                                                                      Contact or transistor for

                                                                                      external input signal

                                                                                                                 Input     Power supply

                           Input device     Isolation                                                            terminal

                                            transformer

    The H3CR-A’s power supply terminal 2 is a common terminal for

    input signals to the Timer. Do not disconnect the wires on terminal 2,

    otherwise the internal circuitry of the Timer will be damaged.

                                                                                                                 Input

                                                                                                                 terminal

                                                            10

                              5, 6, 7

                              G, S, R                                                 It is impossible to provide two independent power switches as shown

    AC or DC               Input terminal                                             below regardless of whether or not the Timers are different in phase.

    Power Supply                                 H3CR-A

                                                                                                                 H3CR-A

                                                                                      Contact or transistor for

                                                         2                            external input signal

                                                                                                                 Input     Power supply

                                                                                                                 terminal

                                                                                                                 Input

                                                                                                                 terminal

23
                                                                                                                                  H3CR-A

Relationship between Input and Power                                    If a relay or transistor is connected to two or more Timers, the input

Supply Circuits (H3CR-A@/-A@S)                                          terminals of those Timers must be wired properly so that they will not

                                                                        be different in phase or the terminals will be short-circuited to one

                                                                        another (refer to the figures below).

An appropriate input is applied to the input signal terminals of the

H3CR-A@/-A@S when one of the input terminals is short-circuited         Incorrect  Contact or transistor for

with the common terminal (terminal 2) for the input signals. Never                 external input signal

use terminal 10 as the common terminal for this purpose, otherwise

the internal circuit of the Timer will be damaged.                                                                   10

                                                                                                6

Correct                                                                                                          H3CR-AP          Power supply

                                                                                                7

                                      5, 6, 7         10

                                      G, S, R                                                                        2

                                  Input terminal  H3CR-A/-AS

           AC or DC

           power supply                                                                                              10

                                                      2                                         6

                                                                                                                 H3CR-AP          Short-circuit current

                                                                                                7

Incorrect                                                                                                            2

                                                      10

                                                                        Correct    Contact   or transistor  for

                                                                                   external  input signal

           AC or DC                               H3CR-A/-AS                                                     10

           power supply               5, 6, 7

                                      G, S, R                                                6

                                  Input terminal      2   *1

                                                                                             7              H3CR-AP               Power supply

                                                                                                                 2

                                  *2                  10

                         Ry                                                                                                       Short-circuit current

                                                                                                                 10

                                                    H3CR-A/-AS                               6

    AC or DC                            5, 6, 7

    power supply                        G, S, R                                                             H3CR-AP

                                  Input terminal                                             7

              Input                                   2

              contact                                                                                            2

*1  Power terminal 2 is a common terminal that is also used for the     When using the timer in an environment where considerable noise

    input signal. Do not use terminal 10 as a common terminal as        occurs, keep the input signal source device, timer unit, and wiring as

    this will damage the internal circuitry.                            far away as possible from the source of the noise. It is also

*2 If a relay or other load is connected here, high voltage will be     recommended that shielded wire be used for the input signal wiring

    applied to the input terminal and damage the internal circuitry.    as a countermeasure for noise.

• The transistor output of the H3CR-A@S is isolated from the internal   Common to All H3CR-A Models

circuitry by a photocoupler, and can therefore be used either as an

NPN output type or a PNP (equivalent) output type.

                                                                        With the H3CR-AP, input wires must be as short as possible. If the

Relationship between Input and Power                                    floating capacity of wires exceeds 1,200 pF (approx. 10 m for cables

                                                                        with 120 pF/m), the operation will be affected. Pay particular

Supply Circuits (H3CR-AP)                                               attention when using shielded cables.

                                                                        The H3CR-A@S transistor output is isolated from the internal

                                                                        circuitry by a photocoupler. Therefore, either NPN or PNP output is

                                                                        possible.

                         H3CR-AP

              AC/DC

              power                     Power supply

              supply     Input circuit  circuit

Since the input circuit and the power supply circuit are configured

independently, the input circuit can be turned ON or OFF irrespective

of the ON/OFF state of the power supply.

It must be noted that a voltage equivalent to the power supply voltage

is applied to the input circuit.

                     ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                     To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                  In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                         24
    MEMO

25
    Solid-state Twin Timers

    H3CR-F

DIN 48  48-mm Twin Timers

• Wide power supply ranges of High Voltage 100 to 240 VAC/100

to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.

• ON- and OFF-times can be set independently and so

combinations of long ON- or OFF-time and short OFF- or ON-

time settings are possible.

• Twenty-four time ranges from 0.05 s to 300 h depending on the

model to be used.

• Models with a flicker ON start or flicker OFF start are available.

• Easy sequence checks through instantaneous outputs for a

zero set value at any time range.

• Length, when panel-mounted with a Socket, of 80 mm or less.                For the most recent information on models that have been

• 11-pin and 8-pin models are available.                                     certified for safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number Legend

H3CR - F @ @               -  @  @

                  1  2  3     4  5

1. Classification                   3. Twin Timer Mode                5. Supply Voltage

F:  Twin timers                     None: Flicker OFF start           100-240AC/100-125DC:     100 to 240 VAC/100 to 125 VDC

2. Configuration                    N:  Flicker ON start              24-48AC/12-48DC:         24 to 48 VAC/12 to 48 VDC

None: 11-pin socket                 4. Time Range

8:  8-pin socket                    None: 0.05 s to 300 h models

Ordering Information

■ List of Models

    Operating modes                     Supply voltage                                         0.05  s  to  300 h models

                                                                             11-pin models                                8-pin models

Flicker OFF start                100 to 240 VAC/100 to 125 VDC    H3CR-F 100-240AC/100-125DC                H3CR-F8 100-240AC/100-125DC

                                 24 to 48 VAC/12 to 48 VDC        H3CR-F 24-48AC/12-48DC                    H3CR-F8 24-48AC/12-48DC

Flicker ON start                 100 to 240 VAC/100 to 125 VDC    H3CR-FN 100-240AC/100-125DC               H3CR-F8N 100-240AC/100-125DC

                                 24 to 48 VAC/12 to 48 VDC        H3CR-FN 24-48AC/12-48DC                   H3CR-F8N 24-48AC/12-48DC

Note: Specify both the model number and supply voltage when       ordering.

    Example: H3CR-F 100-240AC/100-125DC

                                          Supply voltage

                                                                                                                                           26
    H3CR-F

    ■ Accessories (Order Separately)

    Adapter, Protective Cover and Hold-down Clip

                           Name/specifications                                           Models

    Flush Mounting Adapter                                       Y92F-30

                                                                 Y92F-73 *1

                                                                 Y92F-74 *1

    Protective Cover                                             Y92A-48B *2

    Hold-down Clip              For PF085A Socket                Y92H-8

    (Sold in sets of two)       For PL08 or PL11 Sockets         Y92H-7

    Note: Refer to Operation (Common) datasheet for details.

    *1 The Y92A-48B Protective Cover and the Y92F-73/-74 Flush Mounting Adapter cannot be used at the same time.

    *2 The Y92A-48B Protective Cover is made from hard plastic.

    Remove the Protective Cover to change the set value.

    The Y92A-48B Protective Cover and the Y92F-73/-74 Flush Mounting Adapter also cannot be used at the same time.

    Sockets

               Timer                                                      Round Sockets

               Pin                                   Connection                Terminal                                            Models

    11-pin                      Front Connecting                 DIN track mounting      P2CF-11

                                                                 DIN track mounting      P2CF-11-E

                                                                 (Finger-safe type)

                                Back Connecting                  Screw terminal          P3GA-11

                                                                 Solder terminal         PL11

                                                                 Wrapping terminal       PL11-Q

                                                                 PCB terminal            PLE11-0

    8-pin                       Front Connecting                 DIN track mounting      P2CF-08

                                                                 DIN track mounting      P2CF-08-E

                                                                 (Finger-safe type)

                                                                 DIN track mounting      PF085A

                                Back Connecting                  Screw terminal          P3G-08

                                                                 Solder terminal         PL08

                                                                 Wrapping terminal       PL08-Q

                                                                 PCB terminal            PLE08-0

    Note: 1.   The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.

           2.  The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection.

           3.  For details, refer to your OMRON website.

    Terminal Cover

                                Application                                       Model                             Remarks

    For back connecting socket                                   Y92A-48G                                         For P3G-08 and P3GA-11

    Note: For details, refer to your OMRON website.

27
                                                                                                                             H3CR-F

Specifications

■ General

             Item                      H3CR-F                      H3CR-F8                         H3CR-FN                   H3CR-F8N

Operating mode            Flicker OFF start                                            Flicker ON start

Pin type                  11-pin                            8-pin                      11-pin                         8-pin

Operating/Reset method    Time-limit operation/Time-limit reset or self-reset

Output type               Relay output (DPDT)

Mounting method           DIN track mounting, surface mounting, and flush mounting

Approved standards        UL508, CSA C22.2 No.14, NK, Lloyds, CCC

                          Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.

                          Output category according to EN60947-5-1.

Note: For details, refer to your OMRON website.

■ Time Ranges

          Time unit       s (sec)                ×10 s (10 sec)    min (min)           ×10 min (10 min)            h (hrs)   ×10 h (10 hrs)

Fullscale            1.2  0.05 to 1.2            1.2 to 12         0.12 to 1.2         1.2 to 12         0.12 to 1.2         1.2 to 12

setting              3    0.3 to 3               3 to 30           0.3 to 3            3 to 30           0.3 to 3            3 to 30

                     12   1.2 to 12              12 to 120         1.2 to 12           12 to 120         1.2 to 12           12 to 120

                     30   3 to 30                30 to 300         3 to 30             30 to 300         3 to 30             30 to 300

Note: The times that can be set are given. When the time setting knob is turned below “0” until the point where the time setting knob stops, the

output will operate instantaneously at all time range settings.

For details, refer to your OMRON website.

■ Ratings

Rated supply voltage (See notes 1, 2, and 3.)    • 100 to 240 VAC 50/60 Hz/100 to 125 VDC

                                                 • 24 to 48 VAC 50/60 Hz/12 to 48 VDC

Operating voltage range                          85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models

Power reset                                      Minimum power-opening time: 0.1 s

Power consumption                                100 to 240 VAC:   approx. 10 VA (2.1 W) at 240 VAC

                                                 24 VAC/VDC:       approx. 2 VA (1.7 W) at 24 VAC

                                                                   approx. 1 W at 24 VDC

Control outputs                                  Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)

                                                 The minimum applicable load is 10mA at 5VDC (P reference value).

                                                 Contact materials : Ag-alloy

Note: 1.  A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.

2.        Do not use an inverter output as the power supply. Refer to your OMRON website for details.

3.        Refer to your OMRON website when using the Timer together with a 2-wire AC proximity sensor.

                                                                                                                                                  28
    H3CR-F

    ■ Characteristics

    Accuracy of operating                 ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s)

    time

    Setting error                         ±5% FS ±50 ms max.

    Reset time                            0.1 s max.

    Reset voltage                         10% max. of rated voltage

    Influence of voltage                  ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s)

    Influence of temperature              ±1% FS max. (±1% FS ±10 ms max. in ranges of 1.2 and 3s)

    Insulation resistance                 100 MΩ min. (at 500 VDC)

    Dielectric strength                   2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)

                                          2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)

                                          2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)

                                          1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)

    Impulse withstand                     5kV (between power terminals), however, 1kV for 24 to 48VAC, 12 to 48 VDC

    voltage                               5kV (between current-carrying terminal and exposed non-current-carrying metal parts), however 1.5 kV for 24 to 48 VAC,

                                          12 to 48 VDC

    Noise immunity                        ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

    Static immunity                       Malfunction:          8 kV

                                          Destruction:          15 kV

    Vibration resistance                  Destruction:          10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions

                                          Malfunction:          10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions

    Shock resistance                      Destruction:          980 m/s2 three times each in six directions

                                          Malfunction:          98 m/s2 three times each in six directions

    Ambient temperature                   Operating:            −10°C to 55°C (with no icing)

                                          Storage:              −25°C to 65°C (with no icing)

    Ambient humidity                      Operating:            35% to 85%

    Life expectancy                       Mechanical:           20 million operations min. (under no load at 1,800 operations/h)

                                          Electrical:           100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)

    EMC                                   (EMI)                                            EN61812-1

                                          Emission              Enclosure:                 EN55011 Group  1  class  A

                                          Emission              AC Mains:                  EN55011 Group  1  class  A

                                          (EMS)                                            EN61812-1

                                          Immunity              ESD:                       IEC61000-4-2

                                          Immunity              RF-interference:           IEC61000-4-3

                                          Immunity              Burst:                     IEC61000-4-4

                                          Immunity              Surge:                     IEC61000-4-5

                                          Immunity              Conducted Disturbance:     IEC61000-4-6

                                          Immunity              Voltage Dip/Interruption:  IEC61000-4-11

    Case color                            Light Gray (Munsell 5Y7/1)

    Degree of protection                  IP40 (panel surface)

    Weight                                Approx. 100 g

    Note: Refer to the Life-test Curve (Reference).

    ■ Life-test Curve (Reference)

                                  10,000

    Switching operations (x 103)  5,000

                                  1,000

                                          30 VDC L/R = 7 ms                 Reference:     A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1) and

                                  500                                                      a maximum current of 0.1A can be switched at 125V DC and L/R = 7ms.

                                          250 VAC/30 VDC                                   In both cases, a life of 100,000 operations can be expected.

                                          (cosφ = 1)                                       The minimum applicable load is 10 mA at 5 VDC (failure level: P).

                                  100

                                          250 VAC (cosφ = 0.4)

                                          Load current (A)

29
                                                                                                                                     H3CR-F

Connections

■ Block Diagrams

H3CR-F/-F8/-FN/F8N

                                         ON   indicator  OFF  indicator            Zero setting

                                                                                   detection

                                                                                   circuit

                                              Indicator

                                              circuit

                                                                 ROM               RAM      Clock

                                                                                                                            Output

                                                                                                                            circuit

         AC (DC) input  Power    supply                                  One-chip  microcomputer   Time range/unit

                        circuit                                                                    selectors

■ I/O Functions

Inputs                                   ---

Outputs  Control output                  Outputs are     turned  ON/OFF  according to the time set by the ON- and OFF-time           setting knob.

■ Terminal Arrangement

         H3CR-F8/-F8N                                                              H3CR-F/-FN

                                                                                                                    (+)(~)

                        Power supply                                                               Power supply

                                                                                   Note:      Leave terminals 5, 6, and 7 open.

                                                                                              Do not use them as relay terminals.

                                                                                                                                                    30
    H3CR-F

    Operation

    ■ Timing Chart

    tON:      ON set time

    tOFF: OFF set time

    Operating mode                                                                                    Timing chart

    Flicker OFF start                                                                                                                                      Rt

                                                               Power           ON

                                                                               OFF

                                                                                        tOFF          tON           tOFF   tON            tOFF             tOFF

                                                               ONindicator    Lit

                                                                               Not lit

                                                               OFF indicator   Lit

                                                                               Not lit

                                                               Output NO       ON

                                                                               OFF

                                                               Output NC       ON

                                                                               OFF

    Flicker ON start                                                                                                                            Rt

                                                               Power           ON

                                                                               OFF      tON           tOFF          tON    tOFF                  tON           tOFF

                                                               ONindicator    Lit

                                                                               Not lit

                                                               OFF indicator   Lit

                                                                               Not lit

                                                               Output NO       ON

                                                                               OFF

                                                               Output NC       ON

                                                                               OFF

    Note: 1.  Allow a timer reset time     (Rt) of        0.1 s or longer

       2.     When the setting dial is     turned         all the way past 0 for        intantaneous  output,  "t"  (set  time) in  the  above time     chart is     0-sec  operation.

    Nomenclature

    Scale range display windows

    changes as below by turning

    the Time range selector clockwise.

    0         0.2          0.4        0.6  0.8                 1.0        1.2

    0         0.5          1          1.5  2                   2.5        3

    0         2            4          6    8               10         12

    0         5        10             15   20              25         30

                              OFF indicator (green)                                                                 OFF-time unit display window

                              Lit when the output is OFF.                                                           OFF-time unit selector (select one from sec.

                              ON indicator (orange)                                                                 10 s, min., 10 min, hrs, and 10 h)

                              Lit when the output is ON.

                              Scale range display

                              windows                                                                               ON-time setting knob (with orange pointer)

                                                                                                                    For ON-time setting

                                                                                                                    OFF-time setting knob (with green pointer)

                                                                                                                    For OFF-time setting

                              Time range selector (select one

                              from 1.2, 3, 12, and 30 at full                                                       ON-time unit display window

                              scale)

                              For both ON-time and OFF-time.                                                        ON-time unit selector (select one

                                                                                                                    from sec, 10 s, min, 10 min, hrs, and

                                                                                                                    10 h)

31
                                                                                                                                                             H3CR-F

Dimensions

Note: All units are in millimeters unless otherwise indicated.

                                                                                                            17.4           66.6

H3CR-F                                                                                                 5.7        6        52.3

H3CR-FN                                                                  48                                                      0.7

                                                         48                             37  din.                                                44.8 × 44.8

                                                                                                  14  din.

                                                                                                                                                11 pins

                                                                                                            17.4           66.6

                                                                                                       5.7        6        52.3

H3CR-F8                                                                  48                                                      0.7

H3CR-F8N

                                                         48                             37  din.                                                44.8 × 44.8

                                                                                                  14  din.

                                                                                                                                                8 pins

Dimensions with Flush Mounting Adapter

Y92F-30 Flush Mounting Adapter (Order Separately)

                                                                                    Panel         P3G                                         Mounting Hole Dimensions

                                                                                                  Back Connecting Socket

                                                                                                  (Order separately)                          (Conform to DIN 43700.)

                                                                                                                                                0.5 R max.   45+-00.6

                                                                                                                                                                      (N)

                                            58                           52

                                                                                                                                                45+-00.6

                                                         42

                                                         48                  Note:  1.  The orientation of the Adapters for two or more Timers is

                                                                                        different for a horizontal or vertical layout. Make sure the

                                                                                        orientation is correct.

                                                                                        Consecutive Mounting of n Timers

                                                                                        Without Front Covers: N = (48n - 2.5) + 1 - 0

                                                                                        With Front Covers: N = (51n - 5.5) + 1 - 0

                                                                                        With Panel Covers: N = (50n - 4.5) + 1 - 0

                                                                                    2.  The applicable thickness of the mounting panel must be 1 to 5 mm.

Y92F-73 Flush Mounting Adapter (Order Separately)

                                                                                                  Panel

                                                                                                                      P3G                       Adapter mounting holes: Two, 4.5 d

                                                                                                                      Back Connecting Socket

                                                                                                                                              0.5 R max.    52 to 53

                                            88  45±0.15                                                                                       65 to 66                     76±0.2

                                                                                                                           Insert the Timer

                                                                                                                           in this direction.*

                                                                45±0.15

                                                                58                                          52.3

Note:  A Front Cover  and  Flush  Mounting  Adapter cannot      be used  at the     Note: The applicable thickness of the mounting panel must be 1 to

       same time.                                                                           3.2 mm.

                                                                                    * Insert the Timer from the back of the Adapter.

                                                                                                                                                                                    32
    H3CR-F

    Y92F-74 Flush       Mounting    Adapter     (Order Separately)

                                                                                              Panel

                                                            56

                                                                                                           P3G

                                                                                                           Back Connecting Socket     0.5 R max.  45+-00.5

                                                58  45±0.2                       68                                                    55+-00.5

                                                            43±0.2

                                                            50+00.2                                  52.3

    Note: A Front Cover and Flush Mounting Adapter cannot be used at the             Note: The applicable thickness of the mounting panel must              be

            same time.                                                                        1 to 3.2 mm.

    Dimensions with Front Connecting Socket                                Dimensions with Back Connecting Socket

    P2CF-08-@/P2CF-11-@                                                    P3G-08/P3GA-11

                                                                           17.4      81.5                       17.4               81.5

                                                                                     80                                            75

            H3CR-F                              H3CR-F8

            H3CR-FN                             H3CR-F8N

    103.2*                   100.9  92.3*                   90.0                     H3CR-F                           H3CR-F8

                                                                                     H3CR-FN                          H3CR-F8N

                                                                                     +                                             +

                                                                                     Adapter                          Adapter

                                                                                 Y92F-30 P3GA-11                      Y92F-30          P3G-08

                                                                                              (When                                      (When

            P2CF-11          2.3*               P2CF-08     2.3*                              Y92A-48G                                   Y92A-48G

            P2CF-11-E                           P2CF-08-E                                     mounted)                                   mounted)

    * These dimensions vary with the kind of DIN track (reference value).            Note: There are       no  restrictions to the mounting direction.

    ■ Accessories (Order Separately)

    Protective Cover                                                                 Hold-down Clip

    Y92A-48B                                                                         Y92H-8

    To use the Protective Cover with a flush mounting, use the Y92F-30               The Y92H-8 Hold-down Clip is attached to the PF085A socket.

    flush mounting adaptor.

    This Protective Cover cannot be used together with the Y92F-73/-74

    flush mounting adaptor or the panel cover.

                                                                                     Hold-down Clip

                                                                                     Y92H-7

                                                                                     Y92H-7 Hold-down Clip is attached with screws together with the

                                                                                     PL08 socket or the PL11 socket.

                        ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                        To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                    In the interest of product improvement, specifications are subject to change without notice.

33
    Solid-state Star-delta Timers

    H3CR-G

DIN 48  48-mm Star-delta Timer

• A wide star-time range (up to 120 seconds) and star-delta

transfer time range (up to 1 seconds).

                                                                                  For the most recent information on models that have been certified for

                                                                                  safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number                    Legend

H3CR - G 8 @             L  @

    1              2  3  4  5

1. Classification                             3. Outputs                                          5. Supply Voltage

G: Star-delta timer                           None: Star-delta operation contact                  100-120AC: 100 to 120 VAC

2. Configuration                              E:  Star-delta operation contact                    200-240AC: 200 to 240 VAC

8:  8-pin socket                                  and instantaneous contact

                                              4. Dimensions

                                              L:  Long-body model

Ordering Information

■ List of Models

                         Outputs                          Supply voltage                          8-pin models

Time-limit contact                                100 to 120 VAC          H3CR-G8L 100-120AC

                                                  200 to 240 VAC          H3CR-G8L 200-240AC

Time-limit contact and instantaneous contact      100 to 120 VAC             H3CR-G8EL 100-120AC

                                                  200 to 240 VAC          H3CR-G8EL 200-240AC

Note: Specify both the model number and supply voltage when ordering.

    Example: H3CR-G8L 100-120AC

                                        Supply voltage

                                                                                                                                                          34
    H3CR-G

    Accessories (Order Separately)

    ■ Accessories (Order Separately)

    Adapter, Protective Cover, Setting Ring and Panel Cover

                          Name/specifications                                            Models

    Flush Mounting Adapter                                       Y92F-30

                                                                 Y92F-70 *1

                                                                 Y92F-71 *1

    Protective Cover                                             Y92A-48B *2

    Hold-down Clip              For PF085A Socket                Y92H-2

                                For PL08 Sockets                 Y92H-1

    Setting Ring A                                               Y92S-27 *3

    Setting Ring B and C                                         Y92S-28 *3

    Panel Cover                 Light gray (5Y7/1)               Y92P-48GL *4

                                Black (N1.5)                     Y92P-48GB *4

    Note: Refer to Operation (Common) datasheet for detail.

    *1 The Y92A-48B Protective Cover and the Y92P-48G@ Panel Cover can not be used at the same time with the Y92F-70/-71 Flush Mounting Adapter.

    *2  The Y92A-48B Protective Cover is made from hard plastic. Remove the Protective Cover to change to set value.    The Y92F-70/-71 Flush

        Mounting Adapter and the Y92P-48G@ Panel Cover cannot be used at the same time with Y92A-48B Protective Cover.

    *3 The Y92S-27/-28 Setting Ring cannot be used alone. It must be used together with the Y92P-48G@ Panel Cover.

    *4 The Y92A-48B Protective Cover and the Y92F-70/-71 Flush Mounting Adapter cannot be used at the same time with the Y92P-48G@ Panel Cover.

    Sockets

                 Timer                                                    Round Sockets

                    Pin                              Connection                Terminal                                            Models

    8-pin                       Front Connecting                 DIN track mounting      P2CF-08

                                                                 DIN track mounting      P2CF-08-E

                                                                 (Finger-safe type)

                                                                 DIN track mounting      PF085A

                                Back Connecting                  Screw terminal          P3G-08

                                                                 Solder terminal         PL08

                                                                 Wrapping terminal       PL08-Q

                                                                 PCB terminal            PLE08-0

    Note: 1.   The P2CF-08-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.

           2.  The P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection.

           3.  For details, refer to your OMRON website.

    Terminal Cover

                                Application                                       Model                                            Remarks

    For back connecting socket                                   Y92A-48G                For P3G-08 and P3GA-11

    Note: For details, refer to your OMRON website.

35
                                                                                                                           H3CR-G

Specifications

■ General

             Item                                H3CR-G8L                                                       H3CR-G8EL

Functions                     Star-delta timer                                                Star-delta timer  with instantaneous output

Pin type                      8-pin

Operating/Reset method        Time-limit operation/Self-reset

Output type                   Time-limit: SPST-NO (star operation circuit)                    Time-limit:       SPST-NO (star operation circuit)

                                             SPST-NO (delta operation circuit)                                  SPST-NO (delta operation circuit)

                                                                                              Instantaneous:    SPST-NO

Mounting method               DIN track mounting, surface mounting, and flush mounting

Approved standards            UL508, CSA C22.2 No.14, NK, Lloyds, CCC

                              Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.

                              Output category according to EN60947-5-1.

Note: For details, refer to your OMRON website.

■ Time Ranges

                   Time unit                 Star operation time ranges

Scale  number (max.)

6          Set time range     0.5 to 6 s

12                            1 to 12 s

60                            5 to 60 s

120                           10 to 120   s

Star-delta transfer time      Programmable at 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s, or 1.0 s

■ Ratings

Rated supply voltage (See notes 1 and 2.)        100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz)

Operating voltage range                          85% to 110% of rated supply voltage

Power reset                                      Minimum power-opening time: 0.5 s

Power consumption                                100 to 120 VAC:  approx. 6 VA (2.6 W) at 120 VAC

                                                 200 to 240 VAC:  approx. 12 VA (3.0 W) at 240 VAC

Control outputs                                  Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ    = 1)

                                                 The minimum applicable load is 10mA at 5VDC (P reference       value).

                                                 Contact materials : Ag-alloy

Note: 1.   Do not use an inverter output as the power supply. Refer to your OMRON website for details.

       2.  Refer to your OMRON website when using the Timer together with a 2-wire AC proximity sensor.

                                                                                                                                                   36
    H3CR-G

    ■ Characteristics

    Accuracy of operating     ±0.2% FS max.

    time

    Setting error             ±5% FS ±50 ms max.

    Accuracy of Star-delta    ±25% FS + 5 ms max.

    transfer time

    Reset voltage             10% max. of rated voltage

    Influence of voltage      ±0.2% FS max.

    Influence of temperature  ±1% FS max.

    Insulation resistance     100 MΩ min. (at 500 VDC)

    Dielectric strength       2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)

                              2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)

                              2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)

                              1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)

    Impulse withstand         5 kV (between power terminals)

    voltage                   5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)

    Noise immunity            ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)

    Static immunity           Malfunction:  8 kV

                              Destruction:  15 kV

    Vibration resistance      Destruction:  10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions

                              Malfunction:  10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions

    Shock resistance          Destruction:  980 m/s2 three times each in six directions

                              Malfunction:  294 m/s2 three times each in six directions

    Ambient temperature       Operating:    −10°C to 55°C (with no icing)

                              Storage:      −25°C to 65°C (with no icing)

    Ambient humidity          Operating:    35% to 85%

    Life expectancy           Mechanical:   20 million operations min. (under no load at 1,800 operations/h)

                              Electrical:   100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)

    EMC                       (EMI)                               EN61812-1

                              Emission Enclosure:                 EN55011 Group 1 class A

                              Emission AC Mains:                  EN55011 Group 1 class A

                              (EMS)                               EN61812-1

                              Immunity ESD:                       IEC61000-4-2

                              Immunity RF-interference:           IEC61000-4-3

                              Immunity Burst:                     IEC61000-4-4

                              Immunity Surge:                     IEC61000-4-5

                              Immunity Conducted Disturbance:     IEC61000-4-6

                              Immunity Voltage Dip/Interruption:  IEC61000-4-11

    Case color                Light Gray (Munsell 5Y7/1)

    Degree of protection      IP40 (panel surface)

    Weight                    H3CR-G8L: approx. 110 g; H3CR-G8EL: approx. 130 g

    Note: Refer to the Life-test Curve (Reference).

37
                                                                                                                                                           H3CR-G

■ Life-test Curve (Reference)

                              10,000

Switching operations (× 103)  5,000

                              1,000

                                        30 VDC L/R = 7 ms                     Reference:     A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1) and

                              500                                                            a maximum current of 0.1A can be switched at 125V DC and L/R = 7ms.

                                                 250 VAC/30 VDC                              In both cases, a life of 100,000 operations can be expected.

                                                 (cosφ = 1)                                  The minimum applicable load is 10 mA at 5 VDC (failure level: P).

                              100

                                        250 VAC (cosφ = 0.4)

                                        Load current (A)

Connections

■ Block Diagrams

H3CR-G8L

                                                                              Star           Star-delta

                                                                              operation      transfer time

                                                                              time range     selector

                                                                              selector

                                        Power                 Star operation  Star           Star-delta     Star-delta

                              AC input  supply                time            operation      transfer time  transfer time                  Star operation

                                        circuit               oscillation     time counting  oscillation    counting       Output

                                                              circuit         circuit        circuit        circuit        circuit

                                                                                                                                           Delta operation

                                                                                                                                           Star

                                                                                                                                           operation

                                                                                                                           Indicator       indicator

                                                                                                                           circuit         Delta

                                                                                                                                           operation

                                                                                                                                           indicator

H3CR-G8EL

                                                                              Star           Star-delta

                                                                              operation      transfer time

                                                                              time range     selector

                                                                              selector

                                        Power                 Star operation  Star           Star-delta     Star-delta                     Star operation

                              AC input  supply                time            operation      transfer time  transfer time

                                        circuit               oscillation     time counting  oscillation    counting       Output

                                                              circuit         circuit        circuit        circuit        circuit

                                                                                                                                           Delta operation

                                                                                                                                           Star

                                                                                                                           Indicator       operation

                                                                                                                           circuit         indicator

                                                                                                                                           Delta

                                                                                                                                           operation

                                                                                                                                           indicator

                                                                                                                           Instantaneous

                                                                                                                           output circuit

                                                                                                                                                                    38
    H3CR-G

    ■ I/O Functions

    Inputs                                       ---

    Outputs             Control output           If the time reaches the value set with the time setting knob, the star operation output will be turned OFF

                                                 and there will be delta operation output after the set star-delta transfer time has elapsed.

    ■ Terminal Arrangement

    H3CR-G8L                                                                   H3CR-G8EL

                                 Delta           Star                                                                 Delta                          Star

                                 operation       operation             Instantaneous contact                          operation                      operation

                                 contact         contact                                                              contact                        contact

    Note:     Leave terminals 1, 3, and 4 open.                                                   Note:           Leave terminal 4 open. Do          not   use

              Do not use them as relay terminals.                                                                 them as relay terminals.

    Operation

    ■ Timing Chart

    t1:     Star operation time setting

    t2:     Star-delta transfer time

                 Model                                                                            Timing  chart

            H3CR-G8L/-G8EL                                                                                                                                 0.5 s  min.

                                                 Power (2 − 7)                 ON

                                                                               OFF

                                                 Instantaneous output          ON

                                                 (1 − 3) (-E models)           OFF

                                                                                                  t1

                                                 Star operation                ON                                 t2

                                                 output (8 − 5)                OFF

                                                 Delta operation               ON

                                                 output (8 − 6)                OFF

                                                 Star operation indicator      Lit

                                                                               Not lit

                                                 Delta  operation   indicator  Lit

                                                                               Not lit

    Nomenclature

    Scale range display windows

    changes as below by turning

    the Time range selector clockwise.

    0         1  2               3          4    5               6

    0         2  4               6          8    10             12

    0        10  20         30              40   50             60

    0        20  40         60              80   100    120

                            Star operation

                            indicator (green)

                            Delta operation

                            indicator (orange)

                            Scale range display                                                                   Time unit display

                            windows                                                                               (sec is fixed)

                                                                                                                  Time setting knob (for setting

                                                                                                                  star operation time)

                            Star operation time range selector                                                    Star-delta transfer time selector

                            (select one from 6, 12, 60, and 120                                                   (select one from 0.05 s, 0.1 s,

                            at full scale)                                                                        0.25 s, 0.5 s, 0.75 s, and 1.0 s)

                                                                       Star-delta transfer  time  display window

39
                                                                                                                                               H3CR-G

Dimensions

Note: All units are in millimeters unless otherwise indicated.

Dimension of Timer main unit

                                                                                       15                       (78)

                                                                                             6           63.7              13.6

                                                                48                                                    0.7

                                      48                                     39  dia.                                            44.8 ✕  44.8

                                                                                                   79.4

Dimensions with Set Ring and Panel Cover

Y92S-27/-28 (Order Separately)                                                               16.5

                                                                50

                                    50                                           42    dia.

                                                                             Time setting ring     Panel cover

Dimensions with Front Connecting Socket                             Dimensions with Back Connecting                              Socket

P2CF-08-@                                                           P3G-08

                                                                                       15          92.9

                                                                                                   86.4

           101.3*  H3CR-G8@L    99

                                                                                                   H3CR-G8@L

                                                                                                   +

                                                                                                   Adapter

                                                                                                Y92F-30  P3G-08

                                                                                                            (When

                   P2CF-08      2.3*                                                                        Y92A-48G

                   P2CF-08-E                                                                                mounted)

Note: There are no restrictions to the mounting direction.

* These dimensions vary with the kind of DIN track (reference       value).

                                                                                                                                                       40
    H3CR-G

    ■ Accessories (Order Separately)

    Protective Cover                                                    Hold-down Clip

    Y92A-48B                                                            Y92H-2

    To use the Protective cover with a flush mounting, use the Y92F-30  The Y92H-2 Hold-down Clip is attached to the PF085A socket.

    flush mounting adaptor.

    This Protective cover cannot be used together with the Y92F-70/-71

    flush mounting adaptor or the panel cover.

                                                                        Y92H-1

                                                                        Y92H-1 Hold-down Clip is attached with screws together with the

                                                                        PL08 socket.

              ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

              To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                             In the interest of product improvement, specifications are subject to change without notice.

41
    Solid-state Power OFF-delay                                  Timers

    H3CR-H

DIN 48  48-mm Power OFF-delay Timer

• Long power OFF-delay times;

S-series: up to 12 seconds,

M-series: up to 12 minutes.

• Models with forced-reset input are available.

• 11-pin and 8-pin models are available.

                                                                                    For the most recent information on models that have been

                                                                                    certified for safety standards, refer to your OMRON website.

Model Number Structure

■ Model Number                        Legend

Note: This model number legend        includes combinations that are not available. Before ordering, please check the List of Models on page 42    for

       availability.

H3CR - H @ @ L @ @                         Note: Specify the model number, supply voltage, and time range (S or M) when ordering.

         1            2  3  4  5  6

1. Classification                          3. Input                   5. Supply Voltage                       6. Time Range

H:     Power OFF-delay timer               None: Without reset input  100-120AC: 100 to 120 VAC               S:                   0.05 to 12 s

2. Configuration                           R:  With reset input       200-240AC: 200 to 240 VAC               M:                   0.05 to 12 min

None: 11-pin socket                        4. Dimensions              24AC/DC:          24VAC/DC

8:     8-pin socket                        L:  Long-body model        48DC:             48 VDC

                                                                      100-125DC: 100 to 125 VDC

■ List of Models

Input    Output       Supply voltage                       S-series                                         M-series

                                           11-pin models              8-pin models           11-pin models                         8-pin models

Without  DPDT         100 to 120 VAC  ---                      H3CR-H8L 100-120AC S     ---                   H3CR-H8L 100-120AC M

reset                 200 to 240 VAC                           H3CR-H8L 200-240AC S                           H3CR-H8L 200-240AC M

input                 24 VAC/DC                                H3CR-H8L 24AC/DC S                             H3CR-H8L 24AC/DC M

                      48 VDC                                   H3CR-H8L 48DC S                                H3CR-H8L 48DC M

                      100 to 125 VDC                           H3CR-H8L 100-125DC S                           H3CR-H8L 100-125DC M

With                  100 to 120 VAC  H3CR-HRL 100-120AC S ---                          H3CR-HRL 100-120AC M ---

reset                 200 to 240 VAC  H3CR-HRL 200-240AC S                              H3CR-HRL 200-240AC M

input                 24 VAC/DC       H3CR-HRL 24AC/DC S                                H3CR-HRL  24AC/DC M

                      48 VDC          H3CR-HRL 48DC S                                   H3CR-HRL  48DC M

                      100 to 125 VDC  H3CR-HRL 100-125DC S                              H3CR-HRL 100-125DC M

         SPDT         100 to 120 VAC  ---                      H3CR-H8RL 100-120AC S    ---                   H3CR-H8RL 100-120AC M

                      200 to 240 VAC                           H3CR-H8RL 200-240AC S                          H3CR-H8RL 200-240AC M

                      24 VAC/DC                                H3CR-H8RL 24AC/DC S                            H3CR-H8RL 24AC/DC M

                      48 VDC                                   H3CR-H8RL 48DC S                               H3CR-H8RL            48DC M

                      100 to 125 VDC                           H3CR-H8RL 100-125DC S                          H3CR-H8RL 100-125DC M

Note: Specify the model number, supply voltage, and time range (S or M) when ordering.

       Example: H3CR-H8L 100-120AC S

                                               Time range

                                               Supply voltage

                                                                                                                                                        42
    H3CR-H

    ■ Accessories (Order Separately)

    Adapter, Protective Cover and Hold-down Clip

                         Name/specifications                                                Models

    Flush Mounting Adapters                                                Y92F-30                            Note: Refer to Operation

                                                                           Y92F-70 *1                                 (Common) datasheet for

                                                                           Y92F-71 *1                                 details.
                                                                                                              *1.The Y92A-48B Protective
                                                                                                              Cover and the Y92F-70/-71
    Protective Cover                                                       Y92A-48B *2
                                                                                                              Flush Mounting Adapter cannot
    Hold-down Clips                  For PF085A Socket                     Y92H-2
                                                                                                              be used at the same time.

                                     For PL08 or PL11 Sockets              Y92H-1                             *2.The Y92F-48B Protective

                                                                                                              Cover is made from hard
                                                                                                              plastic.

                                                                                                              Remove the Protective Cover

                                                                                                              to change the set value.

    Sockets

                 Timer                                                              Round Sockets

                 Pin                                 Connection                             Terminal                               Models

    11-pin                           Front Connecting                      DIN track mounting                 P2CF-11

                                                                           DIN track mounting                 P2CF-11-E

                                                                           (Finger-safe type)

                                     Back Connecting                       Screw terminal                     P3GA-11

                                                                           Solder terminal                    PL11

                                                                           Wrapping terminal                  PL11-Q

                                                                           PCB terminal                       PLE11-0

    8-pin                            Front Connecting                      DIN track mounting                 P2CF-08

                                                                           DIN track mounting                 P2CF-08-E

                                                                           (Finger-safe type)

                                                                           DIN track mounting                 PF085A

                                     Back Connecting                       Screw terminal                     P3G-08

                                                                           Solder terminal                    PL08

                                                                           Wrapping terminal                  PL08-Q

                                                                           PCB terminal                       PLE08-0

    Note: 1.   The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.

           2.  The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection.
           3.  For details, refer to your OMRON website.

    Terminal Cover

                                Application                                                 Model                                Remarks

    For back connecting socket                                             Y92A-48G                                   For P3G-08 and P3GA-11

    Note: For details, refer to your OMRON website.

    Specifications

    ■ General

                 Item                            H3CR-H8L                           H3CR-H8RL                            H3CR-HRL

    Operating/Reset method      Instantaneous operation/Time-limit reset  Instantaneous operation/Time-limit reset/Forced reset

    Pin type                    8-pin                                                                         11-pin

    Input type                  ---                                       No-voltage input

    Output type                 Relay output (DPDT)                       Relay output (SPDT)                 Relay output (DPDT)

    Mounting method             DIN track mounting, surface mounting, and flush mounting

    Approved standards          UL508, CSA C22.2 No.14, NK, Lloyds, CCC

                                Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.

                                Output category according to EN60947-5-1.

    Note: For details, refer to your OMRON website.

    ■ Time Ranges

                                Time   unit                      S-series                                             M-series

    Scale number (max.)                                          s (sec)                                              min (min)

    0.6         Set time range                   0.05 to 0.6

    1.2                                          0.12 to 1.2

    6                                            0.6 to 6

    12                                           1.2 to 12

    Min. power ON time                           0.1 s min.                                         2 s min.

    Time-up operation repeat period              3 s min.

    Forced-reset repeat period                   3 s min.

    Note: 1.   If the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time.

           2.  Do not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or burning. Refer to Safety Precautions
               (H3CR-H) on page 50 for details.

43
                                                                                                                                     H3CR-H

■ Ratings

Rated supply voltage (See notes  1  and  2.)    100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz), 24 VAC/VDC       (50/60  Hz),  48  VDC,

                                                100 to 125 VDC

Operating voltage range                         85% to 110% of rated supply voltage

No-voltage input (See note 3.)                  ON-impedance:         1 kΩ max.

                                                ON residual voltage:  1 V max.

                                                OFF impedance:        500 kΩ min.

Power consumption                               100 to 120 VAC:  approx. 0.23 VA (0.22 W) at 120 VAC

                                                200 to 240 VAC:  approx. 0.35 VA (0.3 W) at 240 VAC

                                                24 VAC/DC:       approx. 0.17 VA (0.15 W) at 24 VAC

                                                                 approx. 1.0 W at 24 VDC

                                                48 VDC:          approx. 0.18 W at 48 VDC

                                                100 to 125 VDC:  approx. 0.5 W at 125 VDC

Control outputs                                 Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)

                                                The minimum applicable load is 10mA at 5VDC (P reference value).

                                                Contact materials : Ag-alloy

Note: 1.  A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.

      2.  Do not use an inverter output as the power supply. Refer to your OMRON website for details.

      3.  For contact input, use contacts which can adequately switch 1 mA at 5 V.

■ Characteristics

Accuracy of operating     ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)

time

Setting error             ±5% FS ±50 ms max.

Operation start voltage   30% max. of rated voltage

Influence of voltage      ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)

Influence of temperature  ±1% FS max. (±1% FS ±10 ms max. in ranges of 0.6 and 1.2 s)

Insulation resistance     100 MΩ min. (at 500 VDC)

Dielectric strength       2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)

                          2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)

                          2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)

                          1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)

Impulse withstand         5 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;

voltage                   1 kV for 24 VAC/DC, 48 VDC

                          5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120 VAC, 200 to

                          240 VAC, 100 to 125 VDC;

                          1.5 kV for 24 VAC/DC, 48 VDC

Noise immunity            ±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator

                          (pulse width: 100 ns/1 μs, 1-ns rise); ±1 kV (between power terminals) for 48 VDC

Static immunity           Malfunction:   8 kV, Destruction:15 kV

Vibration resistance      Destruction:   10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions

                          Malfunction:   10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions

Shock resistance          Destruction:   980 m/s2 three times each in six directions

                          Malfunction:   98 m/s2 three times each in six directions

Ambient temperature       Operating:     −10°C to 55°C (with no icing),

                          Storage:       −25°C to 65°C (with no icing)

Ambient humidity          Operating:     35% to 85%

Life expectancy           Mechanical:    10 million operations min. (under no load at 1,200 operations/h)

                          Electrical:    100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) (See note)

EMC                       (EMI)                                  EN61812-1

                          Emission Enclosure:                    EN55011 Group 1 class A

                          Emission AC Mains:                     EN55011 Group 1 class A

                          (EMS)                                  EN61812-1

                          Immunity ESD:                          IEC61000-4-2

                          Immunity RF-interferenc:               IEC61000-4-3

                          Immunity Burst:                        IEC61000-4-4

                          Immunity Surge:                        IEC61000-4-5

                          Immunity Conducted Disturbance:        IEC61000-4-6

                          Immunity Voltage Dip/Interruption:     IEC61000-4-11

Case color                Light Gray (Munsell 5Y7/1)

Degree of protection      IP40 (panel surface)

Weight                    Approx. 120 g

Note: Refer to the Life-test Curve(Reference).

                                                                                                                                               44
    H3CR-H

    ■ Life-test Curve(Reference)

                                  10,000

    Switching operations (× 103)  5,000

                                  1,000

                                  500     30 VDC L/R = 7 ms

                                                         250 VAC/30 VDC

                                                         (cosφ = 1)

                                                                                   Reference:   A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1) and

                                                                                                a maximum current of 0.1A can be switched at 125V DC and L/R = 7ms.

                                  100                                                           In both cases, a life of 100,000 operations can be expected.

                                          250 VAC (cosφ = 0.4)

                                                                                   The minimum applicable load is 10 mA at 5 VDC for H3CR-H8L/-HRL and 100 mA at 5

                                          Load current (A)                         VDC for H3CR-H8RL (failure level: P).

    Connections

    ■ Block Diagrams

    Without Reset Input (H3CR-H8L)

                                                                                                         Time range/

                                                                                                         unit selector

                                          AC (DC) input         Power supply       Oscillation           Counting                   Output

                                                                circuit            circuit               circuit                    circuit

                                                                Power failure                                                       Indicator  LCD  Output

                                                                detection circuit                                                   circuit         indicator

    With Reset Input (H3CR-H8RL/-HRL)

                                                                                                         Time range/

                                                                                                         unit selector

                                          AC (DC) input         Power supply       Oscillation           Counting                   Output

                                                                circuit            circuit               circuit                    circuit

                                                                Power failure                                                       Indicator  LCD  Output

                                                                detection circuit                                                   circuit         indicator

                                                 Reset input                                             Input circuit

    ■ I/O                                 Functions

    Inputs                                Reset                          Turns off the control output and resets the elapsed time.

    Outputs                               Control output                 Operates instantaneously when the power is turned on and time-limit   resets when     the  set  time  is up

                                                                         after the power is turned off.

45
                                                                                                  H3CR-H

■ Terminal Arrangement

Note: DC models, including 24 VAC/DC models, have  polarity.

8-pin Models

Without Reset Input (H3CR-H8L)                     With Reset        Input  (H3CR-H8RL)

                                                              Reset

                                                              input

              Power supply                                           Power supply

                                                   Note:      Leave terminal 3 open. Do not  use

                                                              them as relay terminals.

11-pin Model

With Reset Input (H3CR-HRL)

              Reset input

              Power supply

Note:  Leave terminal 6 open. Do not use

       them as relay terminals.

                                                                                                          46
    H3CR-H

    Operation

    ■ Timing Chart

    t:   Set time

    Rt:  Minimum power ON time (S-series: 0.1 s min.; M-series: 2 s min.)

         If the power ON time is less than this value, the Timer may not operate (i.e., output may               not  turn ON).

         Model                                                                 Timing chart

    H3CR-H8L                                                               Rt                           t             Rt         t

                    Power                 ON

                    (See note)            OFF

                    Output (1 − 3)

                    Output (1 − 4)

                    Output (8 − 6)

                    Output (8 − 5)

                    Output                Lit

                    indicator             Not lit

    H3CR-H8RL                                                                                       Rt                Rt

                    Power                      ON                                                             t                     t

                    (See note)                 OFF

                                                                                              0.05 s min.                              0.05 s min.

                    Reset input ON (Short-circuited)
                                 OFF (Open)

                    Output (8 − 6)

                    Output (8 − 5)

                    Output                     Lit

                    indicator                  Not lit

    H3CR-HRL                                                                                  Rt                      Rt

                    Power        ON                                                                        t                     t

                    (See note)   OFF

                                                                                                                                       0.05 s min.

                                                                                              0.05 s

                                                                                              min.

                    Reset input

                    Output (1 − 3)

                    Output (1 − 4)

                    Output (11 − 9)

                    Output (11 − 8)

                    Output       Lit

                    indicator    Not lit

    Note: If the power is turned ON until the set time is up, the timer will be retriggered.

47
                                                                                                                                                                 H3CR-H

Nomenclature

Scale range display windows                                                         Output   indicator  (red)

changes as below by turning                                                                             Scale range display  windows

the Time range selector clockwise.

0       0.1  0.2   0.3              0.4     0.5     0.6

0       0.2  0.4   0.6              0.8     1.0     1.2

0       1    2     3                4       5       6

0       2    4     6                8       10      12

                                                                                                                                          Time setting knob (for setting

                                                                                                                                          power OFF-delay time)

                                                Time range selector    (select

                                                one from 0.6, 1.2, 6,  and 12   at

                                                full scale)

                                                                                                        Time unit display

                                                                                                        S-series:  sec

                                                                                                        M-series: min

Dimensions

Note: All units are in millimeters unless  otherwise indicated.

H3CR-H8L

H3CR-H8RL                                                                                    15                      (78)

                                                                                                 6                 63.7         13.6

                                                             48                                                            0.7

                                                48                                  39 dia.                                               44.8 × 44.8

                                                                                                               79.4                   11 pins

H3CR-HRL                                                                                     15                      (78)

                                                                                                 6                 63.7         13.6

                                                             48                                                            0.7

                                                48                                  39 dia.                                               44.8 × 44.8

                                                                                                                                      8 pins

                                                                                                               79.4

Dimensions with Front Connecting Socket                                             Dimensions with Back Connecting Socket

P2CF-08-@/P2CF-11-@                                                                 P3G-08/P3GA-11

                                                                                                        92.9                          15               92.9

                                                                                    15                  86.4                                   91.4

        H3CR-H8@L                                H3CR-HRL

101.3*             99               112.2*                             109.9                                                                   H3CR-HRL

                                                                                             H3CR-H8@L                                         +

                                                                                                        +                                      Adapter

                                                                                                 Adapter

                                                                                                           P3G-08                         Y92F-30      P3GA-11

                                                                                             Y92F-30           (When                                         (When

        P2CF-08    2.3*                          P2CF-11               2.3*                                    Y92A-48G                                      Y92A-48G

        P2CF-08-E                               P2CF-11-E                                                      mounted)                                      mounted)

Note: There are no restrictions to the mounting direction.

* These dimensions vary with the kind of DIN track (reference value).

                                                                                                                                                                          48
    H3CR-H

    ■ Accessories (Order Separately)

    Protective Cover                                                    Hold-down Clip

    Y92A-48B                                                            Y92H-2

    To use the Protective Cover with a flush mounting, use the Y92F-30  The Y92H-2 Hold-down Clip is attached to the PF085A socket.

    flush mounting adaptor.

    This Protective Cover cannot be used together with the Y92F-70/-71

    flush mounting adaptor or the panel cover.

                                                                        Y92H-1

                                                                        Y92H-1 Hold-down Clip is attached with screws together with the

                                                                        PL08.

49
                                                                                                                                                   H3CR-H

Safety Precautions (H3CR-H)

Note: The undermentioned is common for all H3CR-H models.

■ Power Supplies                                                                           ■ Wiring

The H3CR-H has a large inrush current; provide sufficient power                            The H3CR-H has a high impedance circuit. Therefore, the H3CR-H

supply capacity. If the power supply capacity is too small, there may                      may not be reset if the H3CR-H is influenced by inductive voltage. In

be delays in turning ON the output.                                                        order to eliminate any influence of inductive voltage, the wires

With the H3CR-H@RL, for the power supply of an input device, use an                        connected to the H3CR-H must be as short as possible and should

isolating transformer, of which the primary and secondary windings are                     not be installed alongside power lines. If the H3CR-H is influenced by

mutually isolated and the secondary winding is not grounded.                               inductive voltage that is 30% or more of the rated voltage, connect a

Correct                                                                                    CR filter with a capacitance of approximately 0.1 F and a resistance

                        H3CR-H@RL                                                          of approximately 120  or a bleeder resistor between the power

           (4) <7>                          (7) <10>                                       supply terminals. If there is any residual voltage due to current

           5, 6, 7                          10                                             leakage, connect a bleeder resistor between the power supply

           (1) <5>           Input          (2) <2>                Power supply            terminals.

                    2        terminal       2

                                                                                           ■ Operation

                                                            (  ): H3CR-H8RL                An interval of 3 s minimum is required to turn on the H3CR-H after

                                                            <  >: H3CR-HRL                 the H3CR-H is turned off. If the H3CR-H is turned on and off

                                                                                           repeatedly with an interval of shorter than 3 s, abnormal heating or

                                                                                           burning may occur in internal elements.

                                                                                                                3 s min.

               Input device            Isolation  transformer  is  required.               Power

Incorrect                    H3CR-H@RL

                    (4) <7>                       (7) <10>

                    5, 6, 7                       10                                       Output

                                    Input                                                  state 1

                    (1) <5>         terminal      (2) <2>                Power supply

                        2                         2

                                                                                           Output

                                                                                           state 2

                                                                                           After the forced reset function of the H3CR-H is activated, an interval

                                                                   (     ): H3CR-H8RL      of 3 s minimum is required to activate the forced reset function again.

                                                                   <          >: H3CR-HRL  If the forced reset function is activated repeatedly with an interval of

                                                                                           shorter than 3 s, the internal parts of the H3CR-H may deteriorate

                                                                                           and the H3CR-H may malfunction.

                        Input device           Isolation                                               Power

                                            transformer

■ Input/Output (H3CR-H@RL)                                                                                                3 s min.  3 s min.

                                                                                                       Reset

An appropriate input is applied to the input signal terminal of the Timer                              input

when the input terminal for the input signal is short-circuited. Do not

attempt to connect any input terminal to any terminal other than the input                             Output

terminal or to apply voltage across other than the specified input                         If it is required that the output be turned on repeatedly with an

terminals or the internal circuits of the Timer may be damaged.                            interval of shorter than 3 s, consider use of the H3CR-A in mode D

The H3CR-H@RL uses transformerless power supply. When                                      (signal OFF-delay).

connecting a relay or transistor as an external signal input device,                       On the H3CR-F@, do not set both the ON set dial and OFF set dial to

pay attention to the following points to prevent short-circuiting due to                   the lowest settings. Doing so may damage the contacts.

a sneak current to the transformerless power supply.

If input is made simultaneously from one input contact or a transistor                     ■ Others

to the H3CR-H and a Timer whose common input terminals are used

as power terminals, such as the H3CR-A, a short-circuit current will

be generated. Either input through isolated contacts, or isolate the                       If the H3CR-H is dropped or experiences some other kind of shock,

power supply for one of the Timers.                                                        because a latching relay is used for output, contacts may be reversed

                                                                                           or go into a neutral state. If the H3CR-H is dropped, reconfirm correct

                        H3CR-H@RL                                                          operation.

               4*,  7                  10,  7*

               1*,  5                  2,   2*

                                                           Short-circuit current

           G.  S.   R.

           5   6    7                  10

                        H3CR-A         2

                                                           *: H3CR-H8RL

                    ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                    To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                           In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                                     50
    MEMO

51
Operation (Common)

Note: The undermentioned is common for all H3CR models.

■ Basic Setting                                                            • H3CR-F Twin Timers

                                                                           The display window at the bottom right inside the Time setting knob

Setting of Selectors                                                       shows 1.2, 3, 12, or 30 to indicate the scale number selected with the

                                                                           selector switch on the front at bottom left.

The selectors can be turned clockwise and counterclockwise to

select the desired time unit, time range, or operating mode.

Each selector has a snap mechanism that secures the selector at a

given position. Set the selector at a position at which it is secured. Do

not set it midway between two securing positions or a malfunction

could result from improper setting.

Selection of Operating Mode                                                                  Time range

                                                                                             selector

• H3CR-A Multifunctional Timer

The operation mode A to E, G, and J of the H3CR-A can be selected.

Use a Phillips head or flathead screwdriver to turn the selector

switch. The operation mode can be set to one of eight modes. The

window on the top shows E, G, J, A, B, B2, C, or D to indicate the         Use a Phillips head or flathead screwdriver to turn the selector switch.

selected mode. On the H3CR-A8, the window on the top shows E, J,           For ON-time, the desired time unit (sec, 10 s, min, 10 min, hrs, and 10 h)

B, A, or B2.                                                               is indicated in the ON-time unit display window at the lower right corner

Operating mode                                                             of the front panel and can be changed by turning the ON-time unit

selector                                                                   selector located below the ON-time unit display window.

                                               Operating mode

                                               display window

                                                                                                                         OFF-time unit

                                                                                                                         display window

                                               Groove for                                                                OFF-time unit

                                               screwdriver                                                               selector

                                                                                    Scale range display

               Usable screwdrivers                                                  windows

               Phillips head: No. 0-1                                               Time range selector                  ON-time unit

               Flat head: Width 2.3 to 3.0 mm                                                                            display window

                (i.e., H3CR-A)                                             OFF-time setting knob

Selection of Time Unit and Time Range                                      (with green pointer)                          ON-time unit

                                                                           For OFF-time setting                          selector

• H3CR-A Multifunctional Timer

The desired time unit (sec, ✕10 s, min, ✕10 m, hrs, or ✕10 h) is

displayed in the window below the time setting knob by turning the

time unit selector located at the lower right corner of the front panel.   For OFF-time, the desired time unit (sec, 10 s, min, 10 min, hrs and

A time range (1.2, 3, 12, or 30 for H3CR-A@/2.4, 6, 24, or 60 for          10 h) is indicated in the OFF-time unit display window at the upper

H3CR-A@-301) is selected with the time range selector at the lower         right corner of the front panel and can be changed by turning the

left corner of the front panel, and the selected time range appears (in    OFF-time unit selector located below the OFF-time unit display

the window at the lower right part) within the plastic frame of the time   window.

setting knob.

Time setting                                                                                                             OFF-time unit

knob                                                                                                                     selector

                                               Scale range

Time range                                     display window

selector

                                       Time unit selector

                 Time unit display window

                                                                                                                                                       52
    H3CR

    • H3CR-G Star-delta Timers                                              • H3CR-H Power OFF-delay Timers

    The display window at the bottom right inside the Time setting knob     Use a Phillips head screwdriver or flathead screwdriver to turn the

    shows 6, 12, 60, or 120 to indicate the scale number Star operation     selector switch. The display window at the bottom right inside the

    time selected with the selector switch on the front at bottom left.     Time setting knob shows 0.6, 1.2, 6, or 12 to indicate the scale

                                                                            number selected with the selector switch on the front at bottom left.

                                                                                    Scale range

                                                                                    display window                                   Time setting

    Star operation time                                                                                                              knob

    range selector

                                                                                                           Time range

                                                                                                           selector

                                                                                                     Usable screwdrivers

                                                                                                     Phillips head: No. 0-1

                                                                                                     Flat head: Width 2.3 to 3.0 mm

    Use a Phillips head screwdriver or flathead screwdriver to turn the

    selector switch. The display window at the bottom center of the Time    Setting of Time

    setting knob shows 0.05, 0.1, 0.25, 0.5, 0.75, or 1.0 to show the star  Use the time setting knob to set the desired time.

    -delta transfer time selected with the selector switch on the front at

    bottom right.

    Scale range

    display window                                    Time setting

    Star operation                                    knob

    time range                                        Star-delta

    selector                                          switching time

    Star-delta                                        selector switch

    switching time

    display window

                                 Usable screwdrivers

                                 Phillips head: No. 0-1

                                 Flat head: Width 2.3 to 3.0 mm

    ■ Using the Time Setting Ring for                                       H3CR-A/-G

    Locking the Set Time                                                    Limiting the Setting Range

    Mount the Panel Cover on the Timer, set the desired time with the       Example: To set a range of 10 and 20 s.

    time setting knob, and place Time Setting Ring A onto the time          Mount the Panel Cover on the Timer, set the time setting knob to 10 s

    setting knob so that the time setting notch of Time Setting Ring A is   (the lower limit of the setting range), and place Time Setting Ring C

    in the center of the reset lock position of the Panel Cover.            onto the time setting knob so that the stopper of Time Setting Ring C

                                                                            is on the right edge of the reset lock position of the Panel cover. Next,

                   Time setting  Reset lock position                        set the time setting knob to 20 s (the upper limit of the setting range),

                   notch                                                    place Time Setting Ring B onto the time setting knob so that the

                                                                            stopper of Time Setting Ring B is on the left edge of the reset lock

                                                                            position of the Panel Cover.

                                                                                    Stopper          Reset lock position

    Time Setting Ring A          Panel cover

                                                   Time setting notch

                                 Setting position

                                                                            Time Setting     Time Setting  Panel cover

                                                                            Ring B           Ring C

                                                                                                                                     Range

                                 Example: To set the time to 10 s.

53
                                                                                                                                                                 H3CR

Accessories (Order Separately)                                                    (Common)

Note: The undermentioned is common for all H3CR models.

Note: All units are in millimeters unless otherwise indicated.

Flush Mounting Adaptor

                                                                                                 Panel           P3G

Y92F-30                                                                                                          Back Connecting Socket

                                                58                         52

                                                                42

                                                                48

                                                                                                                      Panel Cutout

                                                                                                                    (Conforms ro DIN 43700)

Note1: The adapters for two or more timers mounted in a vertical line are different in                              0.5 R max.            45+−00.6

         orientation from those mounted in a horizontal line.                                                                             (N)

N can be obtained as follows (n: the number of H3CR models arranged side by side)

Without a Cover: N = (48n - 2.5)+1/-0                                                                                 45+−00.6

With the Protective Cover: N = (51n - 5.5)+1/-0

With the Panel Cover: N = (50n - 4.5)+1/-0

Note2: The applicable thickness of the mounting panel must be 1 to 5 mm.

Y92F-70/-73

                                                                           Panel                                      Panel Cutout

                                                                                      P3G                           Adapter mounting hole Two, 4.5 dia.

                                                                                      Back Connecting Socket

                                                                                                                 R0.5 max.      52 to 53

             88                        45±0.15

                                                                                                                    65 to 66                             76±0.2

                                                                                                 Unit insertion

                                                    45±0.15                                      direction*

                                                    58                         52.3 (63.7)

                                                                               (See note.)

                                                                    Note:  The value shown in

                                                                           parentheses is for           Note:       The applicable thickness of the

Y92F-71/-74                                                                the Y92F-70.                             mounting panel must be 1 to 3.2              mm.

                                                                                                             * Insert timer unit from back side

                                                                                                                 of adapter.

                                                    56                         Panel        P3G                       R0.5 max.                45+−00.5

                                                                                            Back Connecting Socket

                                       58  45±0.2                   68                                                          55+−00.5

                                                                                                 Unit insertion

                                                    43±0.2                                       direction*

                                                    50+-00.2                      52.3 (63.7)           Note:       The applicable thickness of the

                                                                                  (See note.)                       mounting panel must be 1 to 3.2              mm.

                                                                                                             * Insert timer unit from back side

                                                                    Note:  The value shown in                    of adapter.

                                                                           parentheses is for

                                                                           the Y92F-71.

                                                                                                                                                                       54
    H3CR

    Track Mounting/Front Connecting Socket

    P2CF-08

                Eight,                     7.8    3                        4.5

                M3.5 × 7.5 sems

             70 max.                                                       35.4

                                           Two, 4.5 dia.                               Terminal Arrangement/

                                           holes                                       Internal Connections

                                                                                       (Top View)             Surface Mounting Holes

                4

                                50 max.                                                                       Two, 4.5 dia. or two, M4

                                                                20.3 max.

    P2CF-08-E (Finger Safe Terminal Type)

    Conforming to VDE0106/P100                                                                                40±0.2

             Eight,                                          5             4.5

             M3.5 × 7.5 sems               7.8

                                                          3

             70 max.                                      1.3              35.4

                                           Two, 4.5 dia.

                                           holes

                4

                                40±0.2                                     19

                                50 max.                                    20.3

                                                                           21.5 max.

    Track    Mounting/Front Connecting                          Socket

    P2CF-11                                       3                        4.5

                   Eleven,                 7.8

                   M3.5 × 7.5 sems

                                                                                       Terminal Arrangement/

             70 max.                                                           35.4    Internal Connections

                                                                                       (Top View)             Surface Mounting Holes

                                                                                                              Two, 4.5 dia. or two, M4

                4

                                50 max.

                                                             31.2 max.                                        40±0.2

    P2CF-11-E (Finger Safe Terminal Type)

    Conforming to VDE0106/P100

             Eleven,

             M3.5 × 7.5 sems               7.8               5                   4.5

                                                          3

             70 max.                              1.2                            35.4

                                           Two, 4.5 dia.

                                           holes

             4

                                40±0.2                          30

                                50 max.

                                                                31.2 max.

55
                                                                                                                                                                                    H3CR

Back Connecting Socket

P3G-08                                        27 dia.                                                     Terminal Arrangement/

                                                                                                          Internal Connections

                                                                                                          (Bottom View)

                                  45

                                              45                       4.9       17

P3GA-11                                                                                                   Terminal Arrangement/

                                              27 dia.                                                     Internal Connections

                                                                                                          (Bottom View)

                                 45                                                          25.6

                                              45                       4.5                   6.2

                                                                                 16.3

Finger Safe Terminal Cover

Conforming to VDE0106/P100

Y92A-48G                                                                                              Twelve,   6.4  dia. holes

(Attachment for P3G-08/P3GA-11

Socket)

                                                                                       34                            47.7 × 47.7            48 ×  48

                                                                                                                     16.5  24.6   27.6

                                                                                                      47.4

Mounting Track

PFP-100N, PFP-50N                                                                      PFP-100N2

                                                                                                                                                                          16

                                                       7.3±0.15

4.5                                                                                    4.5

                                                               35±0.3       27±0.15                                                                   35±0.3    27  24        29.2

     15  25      25                   25      25                                                  15  25        25                25        25    15                1         1.5

             10                           10           15 (5)               1                               10       1,000              10

                     1,000 (500)                       (See note)

                     (See note)

Note:    The values shown         in parentheses are for

         the PFP-50N.

End Plate                                                                              Spacer

                                                                                                                                                              16

PFP-M                                                                  10              PFP-S                                                5               12

                                                                       6.2       1.8

                                                                       1

                                  50                                             35.5  35.3                                                           44.3          34.8

                                                                            1.8

                                      11.5                             1.3

                                              10       M4 x 8          4.8

                                                       pan head                                                                                             16.5

                                                       screw

                                                                                                                                                                                          56
    H3CR

    Time Setting Ring/Panel Cover for H3CR-A/-G

    There are two types of Panel Covers (Y92P-48GL, and Y92P-48GB),          Refer to Using the Time Setting Ring for H3CR-A/-G on page 53 for

    all of which are available in two colors. Use the most suitable type of  the procedure to attach the Setting Ring.

    Panel Cover with the design of the scaling plate according to the        The Flush Mounting Adapter Y92F-70/Y92F-71 for H3CR-G, Y92F-

    application.                                                             73/Y92F-74 for H3CR-A or the Protective Cover cannot be used.

    To lock the set time, you can lock the setting dial by using a Y92S-27

    Setting Ring and a Y92P-48GL/-48GB Panel Cover. This will help to        Note: The Time Setting Ring/Panel Cover cannot be used for H3CR-

    prevent the set time from being changed accidentally.                          F model or H3CR-H model.

    To restrict the set time range, you can restrict the rotating range of   The Time Setting Ring and Panel Cover should be used as a pair.

    the setting dial by using a Y92S-28 Setting Ring and a 92P-48GL/-

    48GB Panel Cover. Use them to restrict the upper and lower limits of     Locking the Set       Time Setting Ring A (Y92S-27) and Panel

    the setting range.                                                       Time                  Cover (Y92P-48GL, or -48GB)

                                                                             Limiting the setting  Time Setting Ring B or C (Y92S-28), and

                                                                             range                 Panel Cover (Y92P-48GL, or -48GB)

    Y92S-27             Y92S-28                            Y92S-28           Y92P-48GL             Y92P-48GB

    Time Setting A      Time Setting B                     Time Setting C    Light Gray            Black

57
                                                                                                                                          H3CR

Safety Precautions for All H3CR Models

Note: The undermentioned is common for all H3CR models.

Warning Indications

                           Indicates a potentially hazardous situation      In rare circumstances there is a risk of slight electrical

CAUTION                    which, if not avoided, may result in minor       shock, fire, or device damage. Do not disassemble,

                           or moderate injury or in property damage.        modify, repair, or otherwise touch the inside.

Precautions for            Supplementary comments on what to do

Safe Use                   or avoid doing, to use the product safely.

                           Supplementary comments on what to do             In rare circumstances there is a risk of fire if the

Precautions for            or avoid doing, to prevent failure to            screws become loose. Tighten the terminal screws to

Correct Use                operate, malfunction or undesirable effect       the specified torque (1.08N·m).

                           on product performance.

Meaning of Product Safety Symbols                                                               Precautions for Safe Use

                                                                            Do not use the Timer in the following locations.

               Used to warn of the risk of electric shock under             •  Locations with radical temperature changes.

               specific conditions.

                                                                            •  Locations with high humidity that may result in condensation.

                                                                            •  Locations with excessive vibration or shock.

               Used for general prohibitions for which there is no          •  Locations with corrosive gas or dust.

               specific symbol.                                             •  Locations where the Timer is exposed to sprayed water, oil, or

                                                                               chemicals.

                                                                            Pay the utmost attention not to make mistakes in polarity when wiring

               Use to indicate prohibitions when there is a risk of         the Timer.

               minor injury from electrical shock or other source if        Do not connect anything to terminals that are not used.

               the product is disassembled.                                 Risk of internal element damage if a voltage that exceeds the rating

                                                                            is applied.

                                                                            Using a surge absorber is recommended if surge voltages occur.

               Used for general mandatory action precautions for            The H3CR Series uses a transformerless power supply. Do not touch

               which there is no specified symbol.                          the input terminals while the supply voltage is applied, otherwise an

                                                                            electric shock may be received.

                                                                            Verify that the power and output LEDs (LCD) are operating normally.

                           CAUTION                                          In some usage environments, the LEDs/LCD/ resin components may

                                                                            deteriorate faster than normal, resulting in display failure. Inspect and

Risk of fire and explosion due to arcing and relay heat                     replace regularly.

generation that accompanies switching. Do not use in an                     When disposing of this product, follow the procedures for disposal of

environment where flammable or explosive gas is present.                    industrial waste that apply in your region.

                                                                            Verify that the product is the desired product before use.

The H3CR series uses a transformer-less power                               Exercise caution as the outer casing of the timer may be immersed in

supply. Exercise full caution as there is a risk of                         organic solvents (thinner, benzene, etc.), strong alkali, or strong

electrical shock if input terminal is touched when                          acids.

power voltage is applied.

                                                                                           Precautions for Correct Use

The service life of the output relay varies widely

depending on switching capacity and switching                               Changing the Setting

conditions. Use only within the rated load and

electrical life count, based on actual conditions of use.                   Do not change the time unit, time range, or operation mode while the

Risk of contact sticking and burning if used past the                       Timer is in operation, otherwise the Timer may malfunction.

service life. Always use a load current that does not                       The time unit and time range can be set with the respective selectors

exceed the rating, and if a heater is used, use a thermal  switch  in  the  turned clockwise or counterclockwise.

load circuit.

                                                                            The selectors are of notched so that they will snap when they are

                                                                            properly set. Do not set the selectors midway between notches,

Do not remove the outer casing.                                             otherwise the Timer may break or malfunction.

                                                                            Do not use H3CR-A models (except for H3CR-A@S) in flicker mode

                                                                            at the lowest selector setting, or H3CR-F models at the lowest

                                                                            selector setting. Doing so may result in damage to contacts.

                                                                                                                                                       58
    H3CR

    Power Supplies                                                             Others

    A DC power supply can be connected if its ripple factor is 20% or          If the Timer is mounted to a control board, dismount the Timer from

    less and the mean voltage is within the rated operating voltage range      the control board or short-circuit the control board circuitry before

    of the Timer.                                                              carrying out a voltage withstand test between the electric circuitry

    An AC power supply can be connected to the power input terminals           and non-charged metal part of the Timer. This protects the internal

    without regard to polarity. A DC power supply must be connected to         circuitry of the Timer from damage.

    the power input terminals as designated according to the polarity of       If the timer is left for an extended time at high temperature in the

    the terminals.                                                             time-up state (internal relay ON), the internal components

    Make sure that the voltage is applied within the specified range,          (electrolytic capacitors, etc.) may deteriorate faster than normal. For

    otherwise the internal elements of the Timer may be damaged.               this reason, use in combination with a relay, and avoid leaving in the

                                                                               time-up state for an extended time (for example, one month or

    Connect the power supply voltage through a relay or switch in such a       longer).

    way that the voltage reaches a fixed value at once, otherwise the

    Timer may not be reset or a timer error may result.                        Reference example

    Be aware that the operating voltage will rise by 5% if the rated           Use as shown below.

    voltage is applied to the Timer continuously while the ambient

    temperature is close to the maximum permissible ambient

    temperature.                                                                            X2/b    T/a  X1/a       X1/a

    The power supply circuit of any H3CR-A model (except for H3CR-

    A@S), H3CR-F 100-to-240-VAC model, and H3CR-G model is a

    switching circuit. If the power line connected to the power supply                   T        X1                X2                  X  : Auxiliary relay,

    circuit has a transformer with high inductance, a counter-                                                                             MY relay, etc.

    electromotive voltage will be induced by the inductance. To suppress

    the voltage, apply a CR filter to the power supply line.

    Apply the power voltage at once through the switch and relay               Cleaning

    contacts. If not applied at once, power reset may not take place or

    time-up may occur.                                                         Do not use solvents such as thinner. Use commercially available

    When the power is turned on, a rush current (refer to your OMRON           alcohol.

    website) may flow briefly and the timer may not start if there is

    insufficient power capacity. Use a power supply with sufficient

    capacity.

    Mounting Direction

    There are no restrictions to the mounting direction.

    Precautions for EN61812-1

    Conformance

    The H3CR Series as a built-in timer conforms to EN61812-1

    provided that the following conditions are satisfied.

    Make sure that no voltage is applied to any terminals before

    dismounting the Timer from the Socket.

    The output section of the H3CR is provided only with basic isolation.

    The H3CR itself is designed under the following conditions:

    •  Overvoltage category III

    •  Pollution degree 2

    •  Isolation

       Operation parts: Reinforced isolation

       With clearance of 5.5 mm and creepage distance of         5.5 mm   at

       230 VAC

       Output: Basic isolation (See note)

       With clearance of 3 mm and creepage distance of 3         mm at

       230 VAC

    Note: The 11-pin model ensures basic isolation by itself and also

       ensures basic isolation with the 11-pin model mounted to the

       OMRON P2CF-11-@ or P3GA-11 Socket.

    Connect the two output contacts different in polarity to the loads so

    that they will be the same in potential.

                           ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                           To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                 In the interest of product improvement, specifications are subject to change without notice.

59
             Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have

any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

                     for a period of twelve months from the date of sale by Omron (or such other period expressed in writing

                     by Omron). Omron disclaims all other warranties, express or implied.

(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT

             NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE

             PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL

             SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products

or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,

to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the

non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price

of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other

claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,

installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by

Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or

unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system

assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in

writing, are not to be construed as an amendment or addition to the above warranty.

See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is

not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,

or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with

respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it

to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice

to change part numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be

assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to

confirm actual specifications of purchased Product.

Errors and Omissions.

Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is

assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation                 Industrial Automation Company                               Authorized Distributor:

Tokyo, JAPAN

                  Contact:    www.ia.omron.com

Regional Headquarters

OMRON EUROPE B.V.                              OMRON ELECTRONICS LLC

Wegalaan 67-69-2132 JD Hoofddorp               One Commerce Drive Schaumburg,

The Netherlands                                IL 60173-5302 U.S.A.

Tel: (31)2356-81-300/Fax: (31)2356-81-388      Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.                   OMRON (CHINA) CO., LTD.                        © OMRON Corporation 2013  All Rights Reserved.

No. 438A Alexandra Road # 05-05/08 (Lobby 2),  Room 2211, Bank of China Tower,                In the interest of product improvement,

Alexandra Technopark,                          200 Yin Cheng Zhong Road,                      specifications are subject to change without notice.

Singapore 119967                               PuDong New Area, Shanghai, 200120, China       CSM_2_1_0614                             Printed in Japan

Tel: (65) 6835-3011/Fax: (65) 6835-2711        Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  Cat. No. L084-E1-07                      0613 (0696)
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

H3CR-F8-AC100-240    H3CR-H8L-AC/DC24(S)    Y92P-48GM  H3CR-A8E AC100-240/DC100-125  H3CR-F AC100-240

H3CR-F AC/DC24    H3CR-A8AC24-48/DC12-48    H3CR-A-300 AC24-48/DC12-48  H3CR-F-300 AC100-240  H3CR-F

DC12  H3CR-H8L AC200-240 M   H3CR-H8L AC200-240 S   H3CR-H8L DC100-125 S    H3CR-HRL AC100-120 S

H3CR-A8-302 DC24  H3CR-A8 AC24-48/DC12-48   H3CR-A-300-AC100-240/DC100-125  H3CR-A8-AC100-240/DC100-

125  H3CR-G8EL-31 AC200-240  H3CR-F8N AC100-240/DC100-125   H3CR-F AC100-240/DC100-125  H3CR-F8N

AC24-48/DC12-48   H3CR-FN AC/DC24  H3CR-F8 AC24-48/DC12-48  H3CR-H8RL AC200-240 S    H3CR-H8RL

AC/DC24 M  H3CR-HRL AC/DC24 M  H3CR-FN-300 AC100-240   H3CR-H8L DC100-125 M  H3CR-F8N-300 AC/DC24

H3CR-H8RL AC/DC24 S     H3CR-F-300 AC/DC24  H3CR-F AC24-48/DC12-48  H3CRAAC100240DC100125Q1

H3CRA8EAC100240DC100125Q1    H3CRAAC2448DC1248Q1       H3CRA8AC100240DC100125Q1