Mechatronic Analog Timer

H3AM

Please read and understand this catalog before purchasing the

products. Please consult your OMRON representative if you have any

questions or comments. Refer to Safety Precautions on page 7.

Large Setting Dial and Moving Pointers Ideal

for Easy Operation and Monitoring

• Incorporating an easy-to-see large setting dial with moving

pointers.

• Wide time-setting range of 0.2 s to 60 h (available through three

time-range model types)

• Wide AC power supply range (100 to 240 VAC)

• IP65 watertight and dust-tight front panel.

• Approved by UL and CSA.

• Conforms to EN61812-1 and IEC60664-1

4 kV for Low Voltage, and EMC Directives.

• Conforms to EMC standards.

• Six-language instruction manual provided.

• Programmable contact enables the building of a self-holding

relay circuit as well as built-in instantaneous contact. (-NS)

• Memory retention (-NSR)

• Finger protection terminal block

• Enables easy sequence checks through instantaneous outputs

for a zero set value at any time range.

Model Number                          Legend

H3AM - NS             -       -

                   1     2         3

1. Resetting System                   2. Time Range                              3. Accessory

None: Self-resetting                     A:            0.5 s to 30 h              None: Without accessory

R:   Electric resetting                  B:            1 s to 60 h                300:    Waterproof Packing

                                         C:            0.2 s to 12 h                      (Y92S-35) provided

Ordering Information

■ List of Models

Rated supply          Resetting       Control output                                               Time range

voltage               system                                          0.5 s to 30 h (30 s, 3 min,  1 s to 60 h (60 s, 6 min,  0.2 s to 12 h (12 s, 120 s,

                   (See note.)                                        30 min, 3 h, 30 h)           60 min, 6 h, 60 h)         12 min, 120 min, 12 h)

100 to 240         Self-resetting     DPDT contact output             H3AM-NS-A                    H3AM-NS-B                  H3AM-NS-C

VAC                                   (Time-limit output SPDT and

                                      switchable SPDT

                                      (time-limit ↔ instantaneous))

                   Electric           DPDT contact output             H3AM-NSR-A                   H3AM-NSR-B                 H3AM-NSR-C

                   resetting          (Time-limit output SPDT and

                                      instantaneous output SPDT)

Note: The operation of the instantaneous contacts differs for the self-resetting and electric resetting systems. Refer to Timing Charts on page 5

     for details.

                   http://www.ia.omron.com/                                       (c)Copyright OMRON Corporation 2007         All Rights Reserved.         1
                                                                                                                                           H3AM

■ Accessory (Order Separately)

             Item                                  Model

Waterproof Packing                  Y92S-35 (See note.)

Note: Supplied with H3AM-NS@-@-300 models.

Specifications

■ General

Operating mode                      ON-delay

Screw tightening torque             0.98 N·m (10 kgf) max.

Input type                          Voltage input

Output type                         Relay: DPDT

Mounting method                     Flush/Panel mounting, no restriction on mounting angle.

Approved standards                  UL 508, CSA C22.2 No. 14

                                    Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

                                    Output category according to IEC60947-5-1

■ Time Ranges

Model                  Full scale on                                                   Set time unit

                         dial                 s               10 s              min           10 min                   h (hour)            10 h (hour)

H3AM-@@@-A          3                 ---                   0.5 to 30 s   0.05 to 3 min       0.5 to 30 min    0.05 to 3 h            0.5 to 30 h

H3AM-@@@-B          6                 ---                   1 to 60 s     0.1 to 6 min        1 to 60 min      0.1 to 6 h             1 to 60 h

H3AM-@@@-C          12                0.2 to12 s            2 to 120 s    0.2 to 12 min       2 to 120 min     0.2 to 12 h            ---

Note: Instantaneous output is obtained by turning the time setting knob below "0" until the time setting knob  stops.

■ Ratings

Rated supply voltage           100 to 240 VAC (50/60 Hz)

Operating voltage range        85% to 110% of rated supply voltage

Power reset (-NS)              Minimum power-opening time: 0.5 s

Reset input time (-NSR)        Minimum input time:            0.5 s

Reset voltage range (-NSR)     H level: 85 to 264 VAC

                               L level: 0 to 10 VAC

Power consumption              Approx. 9 VA (Approx. 5 W)

Control output                 Contact output: 5 A at 250 VAC, resistive  load  (cosφ  =  1)

Ambient temperature            Operating: –10°C to 55°C (with no icing)

                               Storage:    –25°C to 65°C (with no icing)

Ambient humidity               Operating: 35% to 85%

Note: The minimum applicable load:

H3AM-NS: 10 mA at 5 VDC (failure level: P, reference value)

H3AM-NSR: 100 mA at 5 VDC (failure level: P, reference value)

                      http://www.ia.omron.com/                                         (c)Copyright OMRON Corporation 2007       All  Rights Reserved.  2
                                                                                                                                    H3AM

■ Characteristics

Accuracy of operating time  ±0.7% FS max.

Setting error               ±2% FS max.

Reset time                  Power reset:         0.5 s max.

                            Reset input time: 0.5 s max.

Influence of voltage        ±1% FS max.

Influence of temperature    ±2% FS max.

Insulation resistance       100 MΩ max. (at 500 VDC)

Dielectric strength         2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts

                            2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals

                            1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)

                            1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other

                            2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles

Impulse withstand voltage   3 kV between power terminals

                            4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts

Noise immunity              ±1.5 kV (between power terminals) square-wave noise by a noise simulator

                            (pulse width: 100 ns/1 μs, 1-ns rise)

Static immunity             Malfunction: 8 kV

                            Destruction: 15 kV

Vibration resistance        Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

                            Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

Shock resistance            Destruction: 300 m/s2 3 times each in 6 directions

                            Malfunction: 150 m/s2 (100 m/s2 in the front/back direction) 3 times each in 6 directions

Life expectancy             Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)

                            Electrical:   100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)

Motor life expectancy       20,000 h

EMC                         (EMI):                                          EN61812-1

                            Emission     Enclosure:                         EN55011 class A

                            Emission     AC Mains:                          EN55011 class A

                            (EMS):                                          EN61812-1

                            Immunity     ESD:                               IEC61000-4-2: 6 kV contact discharge

                                                                                         8 kV air discharge

                            Immunity     RF-interference:                   IEC61000-4-3: 10 V/m (Amplitude-modulated,  80 MHz to 1 GHz)

                                                                                         10 V/m (Pulse-modulated, 900   MHz±5 MHz)

                            Immunity     Power Frequency Magnetic  Fields:  IEC61000-4-8: 30 A/m (50 Hz)

                            Immunity     Conducted Disturbance:             IEC61000-4-6: 10 V (0.15 to 80 MHz)

                            Immunity     Burst:                             IEC61000-4-4: 2 kV power-line

                                                                                         2 kV I/O signal-line

                            Immunity     Surge:                             IEC61000-4-5: 1 kV line to line

                                                                                         2 kV line to ground

Enclosure rating            IP65 (front panel only) (See note.) IP20 (terminal section)

Weight                      Approx. 350 g

Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.

     The H3AM-NS@-@-300 model with waterproof packing is available.

                  http://www.ia.omron.com/                                      (c)Copyright OMRON Corporation 2007    All Rights Reserved.    3
                                                                                                                                                              H3AM

Nomenclature

                                                                   Time setting knob (set time)

Moving Pointer (green):                                            Setting pointer (orange)

Displays remaining time.                                           Displays set value.

Power Indicator                                                    Output Indicator (orange)

(green)                                                            Time Unit Indicator

                                                                   Note: The scale goes up to    "3"  with  the  H3AM-@-A and up to  "6" with the  H3AM-@-B.

Instantaneous or                                                   Time Unit Selector

Time-limit Output Selector for

R2 Relay: (only for H3AM-NS-@

models)

Default setting is time-limit output.                              Applicable Time Unit

                                                                                        Full                           Applicable time unit

                                                                   Model                scale         s          10 s  min           10 min        h    10 h

                                                                                        on

                                                                                        dial

                                (Illustrated  Model:  H3AM-@@@-C)  H3AM-@@@-A           3        No              Yes   Yes           Yes           Yes        Yes

                                                                   H3AM-@@@-B           6        No              Yes   Yes           Yes           Yes        Yes

                                                                   H3AM-@@@-C           12       Yes             Yes   Yes           Yes           Yes        No

                                http://www.ia.omron.com/                                         (c)Copyright OMRON Corporation 2007                  All Rights Reserved.  4
                                                                                                                                                                                   H3AM

Operations

■ Timing Charts

H3AM-NS

                                                                                 t      Rt                  t

                    Power supply (1-2)

Time-limit contact NC (3-4, 7-8) (See note 1.)

Time-limit contact NO (3-5, 6-8) (See note 1.)

Instantaneous contact NC (7-8) (See note 1.)

Instantaneous contact NO (6-8) (See note 1.)

            Power indicator (POWER)

                    Output indicator (UP)

          Note: 1.  The R2 contacts (7-8 and 6-8) are programmable and                                                     can be  set  to  either  instantaneous  or  time-limit

                    contacts using the switch located on the bottom of the                                                 Timer.

            2.      Rt is the reset time and t is the set time.

H3AM-NSR

                                                                         RRtt''     tt              RRtt''       tt++tt''

                                                                                                                 tt''

                    PPoowweerr ssuuppppllyy ((11--22))

                    RReesseett ((99--1100))

            TTiimmee--lliimmiitt ccoonnttaacctt NNCC ((33--44))

            TTiimmee--lliimmiitt ccoonnttaacctt NNOO ((33--55))

          IInnssttaannttaanneeoouuss ccoonnttaacctt NNCC ((77--88))

          IInnssttaannttaanneeoouuss ccoonnttaacctt NNOO ((66--88))

            PPoowweerr iinnddiiccaattoorr ((PPOOWWEERR))

                    OOuuttppuutt iinnddiiccaattoorr ((UUPP))

          Note: t is the set time, Rt’                               is  the     reset application  time,   and  t’ is     the  power  interruption  time.

          http://www.ia.omron.com/                                                                               (c)Copyright OMRON Corporation 2007               All Rights Reserved.  5
                                                                                                                                                                    H3AM

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H3AM (Flush Mounting)

                                                                33         85                                                             Mounting Holes

                                  96                            17.7 17.5              20.1                     70

                                                                                                                                                             Four, 5-dia. holes

                                                                                                                                          81-dia. hole

                          96                   27.5 dia.            77.5 dia.                46  70                                                                 70±0.4

                                                                                                                Four, M4x17.5 screw boss  70±0.4

                                                                               Note:         Tightening  torque for panel mounting is as follows:

                                                                                             300 m N·m   ±50 m N·m

■ Accessories (Order Separately)

Waterproof Packing

(Provided with H3AM-NS@-@-300 models.)

Y92S-35

                                          Note: Use Waterproof Packing to provide a level of water protection

                                               that complies with IP65 standards.

                                               Depending on the operating environment, the Waterproof

                                               Packing may deteriorate, contract, or harden and so regular

                                               replacement is recommended.

Installation

■ Internal Connections and Terminal Arrangement

H3AM-NS                                                                                H3AM-NSR

                                                                               Power                 1                                    6

                                                                               Supply                2                                    7

              1                                6

              2                                7                                                     3                                    8

Power Supply

              3                                8                                                     4          R1  R2                    9

              4                                9                                                     5                                    10

                          R1  R2                                                                                                                             Reset

              5               (See note)       10

                                                                                                 Use the same power source for the power supply and

                                                                                                 reset input and wire the circuit so that the terminals (1)

                                                                                                 and (10) terminals (2) and (9) become the same phase

                                                                                                 respectively.

Note: The R2  relay  can  be switched between  instantaneous        and    time-limit contacts   and thus the contact symbol is shown as follows:

                     http://www.ia.omron.com/                                                    (c)Copyright OMRON Corporation 2007                         All Rights Reserved.  6
                                                                                                                                       H3AM

Safety Precautions

■ Precautions for Safe Use                                               ■ Precautions for Correct Use

Observe the following items to ensure the safe use of this product.      Changing Switch Settings

Environmental Precautions                                                Be sure to adjust the time unit selector and instantaneous or time-

•  Store the H3AM within the specified ratings. If the H3AM has been     limit output selector for R2 relay only before the Timer is turned ON,

   stored at temperatures –10°C or lower, let it stand for 3 hours or    otherwise the Timer may be damaged or malfunction.

   longer at room temperature before turning ON the power supply.        Be sure to set the time only when Timer has stopped, otherwise the

•  Use the H3AM within the specified ratings for operating               Timer may malfunction.

   temperature and humidity.

•  Do not operate the H3AM in locations subject to sudden or extreme     Setting the Operating Time

   changes in temperature, or locations where high humidity may

   result in condensation.                                               Do not turn the time setting knob beyond the permissible range. If a

•  Do not use the H3AM in locations subject to vibrations or shock.      precise time setting is required, check the operation of the Timer in

   Extended use in such locations may result in damage due to stress.    trial operation before the Timer is put in actual operation.

•  Do not use the H3AM in locations subject to excessive dust,           Before using the H3AM-NSR, apply voltage between terminals 9 and

   corrosive gas, or direct sunlight.                                    10 to reset the operation.

•  Install the H3AM well away from any sources of static electricity,    When changing the setting time of the H3AM-NSR to a longer time

   such as pipes transporting molding materials, powders, or liquids.    value, be sure to apply voltage between terminals 9 and 10 during

•  Do not use organic solvents (such as paint thinner or benzine),       the change.

   strong alkaline, or strong acids because they will damage the

   external finish.                                                      Others

Usage Precautions                                                        When mounting the Timer on a panel, evenly tighten the Timer to a

•  Install a switch or circuit breaker that allows the operator to       specified torque. If the Timer using waterproof packing is tightened to

   immediately turn OFF the power, and label it to clearly indicate its  a torque other than the specified value, required waterproof

   function.                                                             properties will not be achieved.

•  Be sure to wire the terminals correctly.                              If the Timer is mounted on a control panel, dismount the Timer from

•  Do not install input lines in the same duct or conduit as power       the control panel or short-circuit the circuitry before carrying out a

   supply or other high-voltage lines. Doing so may result in            voltage withstand test between the electric circuitry and non current-

   malfunction due to noise. Separate the input lines from high-         carrying metal part of the machine, in order to prevent the internal

   voltage lines.                                                        circuitry of the TImer from damage.

•  Internal elements may be destroyed if a voltage outside the rated     The internal elements may be damaged if a voltage other than the

   voltage is applied.                                                   rated supply voltage is applied.

•  Maintain voltage fluctuations in the power supply within the          ■ Precautions for EN61812-1

   specified range.

•  Use a switch, relay, or other contact so that the rated power supply  Conformance

   voltage will be reached within 0.1 s. If the power supply voltage is

   not reached quickly enough, the H3AM may malfunction or outputs       The H3AM as a built-in timer conforms to EN61812-1 provided that

   may be unstable.                                                      the following conditions are satisfied:

                                                                         The output section of the H3AM is provided only with basic isolation.

                                                                         The H3AM itself is designed according to the following:

                                                                         • Overvoltage category III

                                                                         • Pollution degree 2

                                                                         On the above basis:

                                                                         Operation parts on the front and bottom: Reinforced isolation

                                                                         With clearance of 5.5 mm and creepage distance of 5.5 mm at 240

                                                                         VAC

                                                                         Output: Basic isolation

                                                                         With clearance of 3.0 mm and creepage distance of 3.0 mm at 240

                                                                         VAC

                        ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                        To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                       In the interest of product improvement, specifications are subject to change without notice.

                     http://www.ia.omron.com/                            (c)Copyright OMRON Corporation 2007      All Rights Reserved.            7
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if

specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL

LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR

STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the product.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety

equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

                                                      Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix

or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual

specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent

the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This catalog shall not be copied for sales or promotions without permission.

This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this

catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

                                                                                                                                                             2007. 3

OMRON Corporation                                                             In the interest of product improvement, specifications are subject to change without notice.

Industrial Automation Company

http://www.ia.omron.com/                                                              (c)Copyright OMRON Corporation 2007                        All Rights Reserved.
This datasheet has been downloaded from:

datasheet.eeworld.com.cn

Free Download

Daily Updated Database

100% Free Datasheet Search Site

100% Free IC Replacement Search Site

Convenient Electronic Dictionary

Fast Search System

www.EEworld.com.cn

All Datasheets Cannot Be Modified Without Permission

               Copyright © Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved