控制器 24 hour/weekly timer

参数
制造商: Omron
产品种类: 控制器
RoHS:

H2F-DFC-AC100/110/120器件文档内容

Motor Time Switch                                                                                                          CSM_H2F-D_DS_E_2_1

H2F-D                                                                             72 mm
                                                                                                              72 mm
ON/OFF Control 48 Times per Day in 15-min
Increments                                                                                                                                           PS
                                                                                                                                                                E
The H2F-D is a Low-cost Time Switch for Affordable
Operation in a Compact DIN 72 x 72-mm Body.
Choose the Ideal Model to Match the Application.

Just insert the trippers for easy setup.
Make exact time settings using the dial.
Three mounting methods.
Lineup includes models with power interruption backup.
Safety standards: UL and CSA (except for H2F-30/-31).

              The H2F-DM, -DMC, -DMF, -DMFC, -30, and -31 use
              nickel metal hydride batteries.
              Dispose of the batteries at a battery recycling location.

Ordering Information

Control   Drive          Power        Power supply     Mounting                  Flush mounting  Surface mounting/
cycle   method                                          method                                    track mounting
                        interruption  voltage
                                                         Control
                        backup                             output        SPST-NO  SPDT           SPST-NO  SPDT

Daily    Synchronous No               100/110/120 VAC Model              H2F-D    H2F-DC         H2F-DF   H2F-DFC
                                      200/220/240 VAC                    H2F-D    H2F-DC         H2F-DF   H2F-DFC
(24 hours) motor                                                                                 H2F-DMF  H2F-DMFC
                                                                                                 ---      H2F-31
         Quartz motor Yes             100 to 240 VAC                     H2F-DM   H2F-DMC
         (See note.)                  12 to 24 VDC                       H2F-30   ---

Note: Always use the Time Switch with the Y92S-42 Battery mounted.

Accessories (Order Separately)

                  Name                Model                  Note: 1. Three gold-colored trippers for ON and three silver-colored
                                                                         trippers for OFF are enclosed with the H2F-D. Separately order
Trippers (1 set for ON and OFF) (See note 1.) Y92S-21                    trippers if more are required.

Battery (See note 2.)                 Y92S-42                        2. The battery is built into the H2F-D. When the battery is nearing the
                                                                         end of its service life, order the model number listed at the left.

                                                                                                                                                                   1
                                                                                                                                   H2F-D

Specifications

Time Specifications

         Type                Cycle      Minimum scale graduation Minimum set time Maximum set time
Daily                24 h
                                        15 min         15 min                     23 h 45 min

Ratings

Power supply voltage                      Synchronous motor: 100/110/120 VAC, 50/60 Hz; 200/220/240 VAC, 50/60 Hz (See note 1.)
Operating voltage range                   Quartz motor: 100 to 240 VAC, 50/60 Hz; 12 to 24 VDC

                                          85% to 110% of rated supply voltage

Power consumption (See note 2.)           Synchronous motor: 3 VA max.
Control output                            Quartz motor: 1 VA max. at 100 to 120 VAC, 4 VA max. at 200 to 240 VAC, 1 W max. at 12 to 24 VDC

                                          15 A at 250 VAC, resistive load

Ambient operating temperature             -10 to 55C (with no icing)

Ambient operating humidity                35% to 85%

Note: 1. Use the switch on the back of the H2F-D to change the frequency.
        2. Inrush current will briefly flow when the power supply is turned ON. For details, refer to Technical Guide for Timers and Time Switches.

Characteristics

                                    Type                                          Daily

Item                                                   Synchronous motor                                   Quartz motor

Operating time deviation (See note 1.)    3 min max.
Voltage influence and temperature
influence

Setting error (See note 2.)               3 min max.

Cyclic error                              3 min max.

Power interruption backup time            ---                                     180 h min. (See note 3.)

Insulation resistance                     100 M min. (at 500 VDC)

Dielectric strength                       2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and non-current-carrying metal
                                          parts and between control output and operating circuit)

                                          1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance         Destruction 16.7 Hz with 2-mm single amplitude for 1 hour each in three directions

                             Malfunction 10 to 55 Hz with 0.25-mm single amplitude for 10 minutes each in three directions

Shock resistance             Destruction 1,000 m/s2 5 times each in 6 directions

                             Malfunction 200 m/s2 once each in 6 directions

Life expectancy                           Contacts: 10,000 operations min., Motor: 20,000 h

Weight                                    Flush-mounting model: Approx. 150 g, Surface-mounting model: Approx. 200 g

Case color                                Light gray (Munsell 5Y7/1)

Note: 1. Deviation in the ON time or OFF time.
        2. Time difference between the set time and time required to start operation when the pointer is set to the present time.
        3. Value when power has been supplied for at least 72 h at initial use.

                                                                                                                                                     2
Mounting Method                                                                                                       H2F-D

Flush Mounting                                Surface Mounting          DIN Track Mounting         Removing the H2F-D
                                                                                                   from the DIN Track

                                                                                                   Use a flat-blade screwdriver to pull down
                                                                                                   the yellow lever at the back of the bottom
                                                                                                   and remove the Time Switch.

                                                                                                                                            H2F-@@F

72 72 45 mm (H W D)                   95 72 50 mm (H W D)                          Location of yellow lever
  (below faceplate: 29 mm)
                                               Mounting Screw Dimensions
    Panel Cutout Dimensions
    (according to DIN 43700)

                                   17.5 27.5

                                              Two, M3                            Screw size:
                                                                        600.2 M3 45 (enclosed)

          68  +0.7  Adapter
              0
                                                                610.2

68  +0.7
    0

Panel thickness: 1 to 3.2 mm

Note: The mounting adapter
        and mounting screws
        are enclosed.

                                                                                                                                                     3
                                                                                                                  H2F-D

Connections

Synchronous Motor Models: SPST-NO                                                  Synchronous Motor Models: SPDT

Output                                                                             Output

H2F-D                                      H2F-DF                                  H2F-DC                H2F-DFC

Note: 100-V-class models differ from 200-V-class models. They cannot be used together.

Quartz Motor Models: SPST-NO Output                                                Quartz Motor Models: SPDT Output

H2F-DM, H2F-30                             H2F-DMF                                 H2F-DMC               H2F-DMFC, H2F-31

Note: On the H2F-30 (12 to 24 VDC),                                                                      Note: On the H2F-31 (12 to 24 VDC),
        terminal number 2 is positive and                                                                        terminal number 2 is positive and
        terminal number 3 is negative.                                                                           terminal number 3 is negative.

Note: 1. Use a separate power supply for the load.

        2. Screw tightening torque:
               Maximum torque: 0.98 Nm

        3. Use the same type of lead wires when connecting lead wires to the terminal block. If different wire types are used, it will not be possible
            to tighten the thin lead wires, and the wires may become disconnected during use.

        4. Recommended wire: AWG 18 to 24 (cross-sectional area: 0.205 to 0.823 mm2), solid wire or twisted wire.

        5. Do not connect more than two crimp terminals to the same terminal.

Nomenclature

       Mounting Holes                               POWER                    Power indicator (red)        Time Setting
   ON/OFF operation
   selector knob                                                             (See note.)                 Insert the trippers into the scale graduation
                                                                                                         at the desired times.
Dial rotation direction                                                      Dial
(clockwise)                                                                                              Insert gold trippers for times the load is to
                                                                             Tripper                       be turned ON and silver trippers for times
                                                                               Gold: ON time setting       the load is to be turned OFF.
                                                                               Silver: OFF time setting
                                                                                                         Note: 1. Be sure to insert the trippers all
Manual switch                                                                Mounting Holes                          the way.

                                                                                                                 2. Set the trippers in alternating
                                                                                                                     positions only after thoroughly
                                                                                                                     checking the ON and OFF
                                                                                                                     positions.

                         Time setting knob         Holes for spare trippers

Note: Only quartz motor models have a power indicator.

                                                                                                                                                          4
                                                                                                                   H2F-D

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H2F-D (C)           72                                             16 17     1.3

H2F-DM (C)

H2F-30

             72                                                                   65.5

                                                                           45

                                                                   Note: The terminal screws are M3.5.

H2F-DF (C)                             65.5                        50
H2F-DMF (C)                              72
H2F-31                                                                    9       6
             95
                                                                   72

                                                                                                                6
                                                                                               29

                                                                      Note: The terminal screws are M3.5.

                 2                                              2

                                                                                                                          5
                                                                                                                                                                                            H2F-D

Safety Precautions                                                                                                                           3. If the lead wire has been    Panel          Adapter
                                                                                                                                                 installed in front of the               B
Refer to Safety Precautions for All Timers.                                                                                                      panel, place the Time                          Time
                                                                                                                                                 Switch on part A of the     Lead wire          Switch
                           !WARNING                                                                                                              adapter and push it in
                                                                                                                                                 toward B. Then secure the
Minor injury may occasionally occur due to the battery                                                                                           Time Switch by tightening
bursting, igniting, or leaking. Never short-circuit the                                                                                          the screws as described in
positive and negative terminals, disassemble the battery,                                                                                        step 2.
deform it under pressure, or dispose of it in fire.

                            !CAUTION                                                                                                                                                                                                                  A

Minor injury by electric shock may occasionally occur. Do                                                                                    Setting the Time
not touch any of the terminals while power is being
supplied. Be sure to mount the terminal cover after wiring.                                                                                  Turn the center knob clockwise to set
                                                                                                                                               the time. Product failure may occur if
Unexpected operation may occasionally occur.                                                                                                   the knob is turned counterclockwise
Before changing times or other settings while power is                                                                                         or the knob is turned while the
being supplied, either turn OFF the power on the load                                                                                          triggers are being pressed.
side or set the output ON/OFF switch to OFF and confirm
the safety of the system.                                                                                                                     Set the hour to the arrow at the
                                                                                                                                               upper left and set minutes to the
Fire may occasionally occur. Tighten the terminal screws                                                                                       arrow on the center knob.
to the rated torque.
                                                                                                                                              The gold-colored triggers are for ON
Minor electric shock, fire, or product failure may                                                                                             and the silver-colored triggers are for
occasionally occur. Do not allow metal fragments, copper                                                                                       OFF. Securely push in the triggers
wire scraps, or shavings from installation work to fall                                                                                        with the wider part facing the outer
inside the Time Switch.                                                                                                                        part of the dial.
Minor electric shock, fire or product failure may
occasionally occur. Never attempt to disassemble,                                                                                             Insert the spare triggers into the
modify, or repair the product or touch any of the internal                                                                                     holes at the lower right for storage.
parts.
                                                                                                                                             Manual Switch
Minor injury due to explosion may occasionally occur. Do
not use the product where it is subject to flammable or                                                                                      Models with SPST-NO Output
explosive gas.
                                                                                                                                             The output will turn OFF regardless of trigger settings when the
Precautions for Correct Use                                                                                                                 manual switch at the lower left of the front panel is set to OFF. The
                                                                                                                                             output will turn ON regardless of trigger settings when the manual
Mounting                                                                                                                                     switch is set to ON.
                                                                                                                                             The output will turn ON and OFF according to the trigger settings
Panel Flush Mounting                                                                                                                         when the manual switch is set to AUTO.

1. As illustrated at the right,  Panel                                                                                                       Models with SPDT Output
bend the enclosed adapter in A
                                                                                                                                    Adapter   Load 1 (terminals 4 and 5) and load 2 (terminals 5 and 6) will both
the direction of A, and then                                                                                                        B          turn OFF when the manual switch at the lower left of the front panel
                                                                                                                                               is set to OFF.
push part B in the direction of
                                                                                                                                              The output will turn ON and OFF according to the trigger settings
the arrow (i.e., toward the                                                                                                                    when the manual switch is set to AUTO. Load 1 (terminals 4 and 5)
                                                                                                                                               will turn ON and load 2 (terminals 5 and 6) will turn OFF when the
back of the panel cut).                                                                                                                        manual switch is set to ON.

                                                                                                                                 A            Check the output indicator when returning operation to AUTO. If the
                                                                                                                                               knob has been touched or the output indicator has changed
2. Once the adapter has been                                                                                                                   because of vibration or shock, turn the knob, switch the output, and
    mounted, insert the Time                                                                                                                   then return operation to AUTO.
    Switch as illustrated at the
    right. Secure the Time Switch                                                                                                            Output Indicator and ON/OFF Switch
    in two places using the                                                                                                                  Knob
    enclosed screws (M3 16)
    tightened with a torque of                                                                                                                The output indicator at the upper left of the front panel shows the
    0.58 Nm max.                                                                                                                              output status when the manual switch is set to AUTO.
                                                                                                                                               The output can also be manually
                                                                                                                                               switch ON or OFF by turning the
                                                                                                                                               knob clockwise (i.e., in the
                                                                                                                                               direction of the arrow). (This is
                                                                                                                                               possible only when the manual
                                                                                                                                               switch is set to AUTO.)

                                                                                                                                              Do not turn the ON/OFF switch knob when the manual switch is set
                                                                                                                                               to ON or OFF. Do not turn the Knob counterclockwise.

                                                                                                                                                                                                                                                         6
                                                                 H2F-D

H2F-D/-DF Series: Synchronous Motor
Models

Before mounting the Time Switch, set the
frequency switch to the frequency for the
region where the Time Switch will be
used.
(East Japan: 50 Hz, West Japan: 60 Hz)

H2F-DM Series and H2F-30/-31: Quartz
Motor Models

Remove the battery        Press from the top.
  cover on the back of the            Battery cover
  Time Switch. Be sure to
  insert the battery                                 Slide out.
  before supplying power.
  Operating the Time
  Switch without the
  battery mounted will
  increase the time error.
  Always mount the
  battery.

Pay careful attention to the polarity
  when inserting the battery. Insert
  the battery following the polarity
  marked in the battery box of the
  Time Switch. Before using the Time
  Switch, be sure to close the battery
  cover after the battery is inserted.

The enclosed battery is fully
  charged. In the rare event that battery performance decreases due
  to natural discharging, the 180-hour power interruption backup
  function will back up operation if power has been continuously
  supplied for 72 hours after installing the battery in the Time Switch.
  If the battery is completely discharged, the Time Switch may not
  operate when the battery is installed. If the Time Switch does not
  operate, supply power for at least 3 min, and then set the time.

Turning the power supply ON and OFF will extremely shorten the
  service life of the battery. Use the Time Switch with the power
  supplied continuously.

The service life of the battery is approximately three years (at room
  temperature). If the battery has been used for three years or more,
  replace it as soon as possible. Using the battery close to the end of
  its service life will increase the time error.

The battery may leak or cause corrosion due to excessive
  discharge if the H2F is left unused for an extended period with the
  battery mounted. Be sure to remove the battery before storing the
  H2F.

Turn OFF the power supply before replacing the battery.
Use only the specified battery (Y92S-42). The battery may leak or

  burst if any other battery is used, possibly resulting in equipment
  damage or injury.

Other Precautions

Always use a thermo-switch on the load circuit when a heater is
  used.

Operate the Time Switch within the specified rating ranges for
  vibration and shock.

The H2F is not waterproof or oil resistant. Do not use the H2F in
  locations subject to water splashing or oil contact.

                          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                            In the interest of product improvement, specifications are subject to change without notice.

                                                                                 7
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2008.11
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2008 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved