    Motor Timer

    H2C

                                                                                                                                   CSM_H2C_DS_E_2_1

DIN-sized 48 x 48 Motor Timer with Simple

Operation for Switching Time Specifications

• Three Motor Timers cover the wide time range of 6 s to 30 h with

easy operation from the operation panel.

• Five time specifications for each model with linked time display.

• DIN-standard size of 48 x 48 mm.

• Easily check operation with neon lamp.

• Models with sockets and models with top wiring are also avail-

able.

• Certified for UL and CSA safety standards.

• Conforms to EN 61812-1 (except models that end with “-F”) and

CE Marking.

Model Number Structure

■ Model Number Legend

H2C-@ @

        1  2

1.  External Connection/Attachment                                   2.          Operation/Resetting System

    None: 11-pin socket                                                          None: Time-limit operation/self-resetting

    S:  11-pin socket/time setting ring                                          R:       Time-limit operation/electric resetting

    8:  8-pin socket

    F:  Front screw

Ordering Information

■ List of Models

Operation/resetting      Internal             Terminal               Time-limit      Instantaneous       Attachment                        Model

        system           connection                                  contact              contact

Time-limit operation/    Parallel motor and  8-pin socket   SPDT                     SPDT           ---                            H2C-8

self-resetting           clutch connection

                         Separate motor      11-pin socket                                                                         H2C

                         and clutch                                                                 Y92A-Y1 Time                   H2C-S

                         connection                                                                 Setting Ring

                                             Front screw                                            ---                            H2C-F

Time-limit operation/                        8-pin socket   SPDT                     ---            ---                            H2C-8R

electric resetting                           11-pin socket                           SPDT                                          H2C-R

                                                                                                    Y92A-Y1 Time                   H2C-SR

                                                                                                    Setting Ring

                                             Front screw                                            ---                            H2C-FR

Note: Specify both the supply voltage and time range code (A, B, or C) in addition to the model number when ordering.

        Example: H2C-S 24 VAC B

                                     Time range code

                                     Supply voltage

                                                                                                                                                     1
                                                                                                                                        H2C

■ Accessories (Order Separately)

                              Name/specifications                                                                 Models

Flush Mounting Adapter                                                             Y92F-30

Time Setting Ring (See note 1.)                                                    Y92A-Y1

Mounting Track                         50 cm (l) × 7.3 mm (t)                      PFP-50N

                                       1 m (l) × 7.3 mm (t)                        PFP-100N

                                       1 m (l) × 16 mm (t)                         PFP-100N2

End Plate                                                                          PFP-M

Spacer                                                                             PFP-S

Protective Cover                                                                   Y92A-48B

Track Mounting/Front Connecting        8-pin                                       P2CF-08

Socket                                 8-pin, finger safe type                     P2CF-08-E

                                       11-pin                                      P2CF-11

                                       11-pin, finger safe type                    P2CF-11-E

Back Connecting Socket                 8-pin, screw terminal                       P3G-08

                                       8-pin, finger safe type                     P3G-08 with Y92A-48G (See note 2.)

                                       11-pin                                      P3GA-11

                                       11-pin, finger safe type                    P3GA-11 with Y92A-48G (See note 2.)

Hold-down Clip (See note 3.)           For PL08 and PL11 Sockets                   Y92H-1

                                       For PF085A Socket                           Y92H-2

Note: 1.  Supplied with H2C-S/-SR models.

   2.     Y92A-48G is a finger safe terminal cover which is attached  to  the   P3G-08 or P3GA-11 Socket.

   3.     Hold-down Clips are sold in sets of two.

Specifications

■ Time Ranges

Five time ranges are available for each timer by turning the time range selector every 60 degrees.

Note: Rated time is displayed on the window.

Time range code                                                       Position of time range selector

A                  1.25 to 30 s                7.5 s to 3 min             1.25 to 30 min            7.5 min to 3 h        1.25 to 30 h

B                  0.2 to 6 s                  2 to 60 s                  0.2 to 6 min              2 to 60 min           0.2 to 6 h

C                  0.5 to 12 s                 5 to 120 s                 0.5 to 12 min             5 to 120 min          0.5 to 12 h

■ Ratings

                  Item                                                                        H2C

Rated supply voltage (motor and               24, 48, 100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note)

clutch)

Operating voltage range                       85% to 110% of rated supply voltage

Power consumption                             4.2 VA max. (3.96 W max.)

Reset voltage                                 10% max. of rated supply voltage

Reset time                                    Minimum power-opening time: 0.5 s

                                              Minimum pulse width:        0.5 s

Control outputs                               6 A at 250 VAC, resistive load (cosφ = 1)

Mounting method                               Flush mounting (except for H2C-F/-FR models), surface mounting, DIN track   mounting

Note: The front panel of the timer is  color  coded to identify the following supply voltage classifications:

   100 to 120 V: Blue

   200 to 240 V: Red

   Other classes: Black

                                                                                                                                             2
                                                                                                                                 H2C

■ Characteristics

Accuracy of operating time      ±0.5% FS max. 〈±1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time range

                                code C)

Setting error                   ±2% FS max.

Reset time                      0.5 s max.

Influence of voltage            ±1% FS max.

Influence of temperature        ±2% FS max.

Insulation resistance           100 MΩ min. (at 500 VDC)

Dielectric strength             2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)

                                2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of different

                                polarities)

                                1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance            Destruction:     10 to 55 Hz with 0.375-mm single amplitude for 1 h each in three directions

                                Malfunction:     10 to 55 Hz with 0.25-mm single amplitude for 10 min each in three directions

Shock resistance                Destruction:   1,000 m/s2

                                Malfunction:   150 m/s2

Ambient temperature             Operating:     –10°C to 50°C

                                Storage:       –25°C to 65°C

Ambient humidity                Operating:       45% to 85%

Life expectancy                 Mechanical:      10,000,000 operations min. (under no load at 1,800 operations/h)

                                Electrical:      200,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)

                                                 See Life-test Curve for other details.

Motor life expectancy           20,000 h

Approved standards              UL917, CSA C22.2 No.14.

                                Conforms to EN61812-1 and IEC60664-1 4 kV/1 (except for H2C-F@ models).

                                Output category according to EN60947-5-1 (except for H2C-F@ models).

EMC (except for H2C-F@ models)  (EMI)                        EN61812-1

                                Emission Enclosure:          EN55011 Group 1 class A

                                Emission AC Mains:           EN55011 Group 1 class A

                                (EMS)                        EN61812-1

                                Immunity ESD:                IEC61000-4-2:               6 kV contact discharge (level 3)

                                                                                         8 kV air discharge (level 3)

                                Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)

                                Immunity Burst:              IEC61000-4-4:               2 kV power-line (level 3)

                                                                                         2 kV I/O signal-line (level 4)

                                Immunity Surge:              IEC61000-4-5:               1 kV line to line (level 3)

                                                                                         2 kV line to ground (level 3)

Case color                      Light gray (Munsell 5Y7/1)

Degree of protection            IP40 (panel surface)

Weight                          H2C series:      approx. 180 g

                                H2C-F series:    approx. 270 g

                                                                                                                                      3
                                                                                                                         H2C

Connections

■ Terminal Arrangement

Note: The connections diagrams are for when the  clutch  is  in  the  excited, reset state.

H2C-8                                                                 H2C-8R

H2C(-F)/H2C-S                                                         H2C-(F)R/H2C-SR

                  Clutch coil                                                                         Clutch coil

               (B2)        6                                                                             6

                  5  (B1)         7                                                                5             7
       (16)          (B2)                                                                                (B2)

                     (22)     (B1)   8                                                                       (B1)

       (18) 4  (16) (24)                                                                     4 (16)                  8

       (A1)    (18)(A2)           (22)                                                                           (22)

       (135)   (21)             (24) 9                                                       3  (18)             (24) 9

               (A1)           (A2)                                                              (A1)           (A2)

               2     (15) (21)       10                                                         2     (15) (21)     10

                     1        11                                                                      1     11

                  (DIN 46 199-5)                                                                   (DIN 46 199-5)

                                                                                                                              4
                                                                                                                                                                        H2C

Operation

■ Timing Chart

H2C-8                                                                         H2C-8R                                                     Power failure

                            t              Rt        t          Rt                                            Rt                 Rt      time (t')        Rt

                                                                                                                      t

Power (2-7)                                                                   Power and motor (2-7)

Time-limit contacts                                                                                                                      t+t'

NC (8-5)                                                                      Power and clutch (1-4)

Time-limit contacts

NO (8-6)                                                                      Time-limit contacts

Instantaneous contacts                                                        NC (8-5)

NC (1-4)                                                                      Time-limit contacts

Instantaneous contacts                                                        NO (8-6)

NO (1-3)

Timing operation indicator                                                    Timing operation indicator

lamp (OFF at time-up)                                                         lamp (OFF at time-up)

                                                   Rt: Resetting time                                                                               Rt: Resetting time

                                                                                                                                         Power failure

H2C(-F)/H2C-S                                                                     H2C-(F)R/H2C-SR                 Rt                 Rt  time (t')

                                   t           Rt            t                Rt                                         t                                    Rt

Power and motor                                                                   Power and motor

2(A1)-10(A2)                                                                      2(A1)-10(A2)                                                      t+t'

Power and clutch                                                                  Power and clutch

7(B1)-6(B2)                                                                       7(B1)-6(B2)

Time-limit contacts                                                               Time-limit contacts

NC 1(15)-4(16)                                                                    NC 1(15)-4(16)

Time-limit contacts                                                               Time-limit contacts

NO 1(15)-3(18)                                                                    NO 1(15)-3(18)

Instantaneous contacts                                                            Instantaneous contacts

NC 11(21)-8(22)                                                                   NC 11(21)-8(22)

Instantaneous contacts                                                            Instantaneous contacts

NO 11(21)-9(24)                                                                   NO 11(21)-9(24)

Timing operation indicator                                                        Timing operation indicator

lamp (OFF at time-up)                                                             lamp (OFF at time-up)

(See note.)                                             Rt:  Resetting  time      (See note.)                                                             Rt: Resetting time

                            Note:     For  the types rated at 24 and 48 VAC, the timing operation                     indicator  is not equipped.

Nomenclature

                 Timing operation              Time range

                 indicator                     selector

                                      Rated voltage

                                      color code

                                                                                                                                                                              5
                                                                                                                                        H2C

Dimensions

Note: All units are in millimeters unless otherwise indicated.

H2C/H2C-S/H2C-R/H2C-SR/H2C-8/H2C-8R

                                                                                                       For Flush Mounting

                                                                                  44.8 x 44.8  45+0.6
                                         37 dia.                                               −0

                                                                                                             45+0.6
                                                                                                              −0

                                                                                  For a load current of 3 A max., dimension L becomes

                                                                                  3 mm min. with an interval of 0 mm between timers.

                                                                                  For a load current of 6 A max., dimension L becomes

                                                                                  8 mm min. with an interval of 5 mm between timers.

                                                                                  When using in locations with high ambient

                                                                                  temperatures, ensure that there is an interval of at

                                                                                  least 5 mm between timers.

H2C-F/H2C-FR                                                                                           Mounting Holes

                                                                                                                           Two, M4 or 4.5 dia. holes

                                                                                    For a load current of 1 A max., dimension L becomes

                                                                                    10 mm min. with an interval of 0 mm between timers.

                                                                                    For a load current of 3 A max., dimension L becomes

                                                                                    15 mm min. with an interval of 5 mm between timers.

                                                                                    For a load current of 6 A max., dimension L becomes

                                                                                    20 mm min. with an interval of 10 mm between timers.

Dimensions with Front Connecting Socket                                  Dimensions with Back Connecting Socket

P2CF-08-@/P2CF-11-@                                                      P3G-08/P3GA-11

                                                                16.3          81.5                     16.3          92.2

                                                                              80                                     85.7

        H2C

        H2C-S                H2C-8                                       H2C

100.8*  H2C-R        103.1*  H2C-8R                                      H2C-S                                    H2C-8

        H2C-SR                                                           H2C-R                                    H2C-8R

                                                                         H2C-SR                                   +

                                                                         +                                        Adapter

                                                                         Adapter

                                                                                  P3GA-11                                  P3G-08

                                                                         Y92F-30    (When                    Y92F-30       (When

        P2CF-11              P2CF-08                                                Y92A-48G                               Y92A-48G

        P2CF-11-E            P2CF-08-E                                              mounted)                               mounted)

*These dimensions vary with the kind of DIN track (reference    value).

                                                                                                                                                      6
                                                                                                                                 H2C

■ Accessories (Order Separately)

Adapter for Flush Mounting

Y92F-30

Track Mounting/Front Connecting Socket

P2CF-08

         Eight,                        7.8    3                      4.5

         M3.5 x 7.5 sems

         70 max.                                                     35.4

                                       Two, 4.5 dia.                            Terminal Arrangement/

                                       holes                                    Internal Connections

                                                                                (Top View)             Surface Mounting Holes

         4

                            50 max.                                                                    Two, 4.5 dia. or two, M4

                                                         20.3  max.

P2CF-08-E (Finger Safe Terminal Type)

Conforming to VDE0106/P100                                                                             40±0.2

         Eight,                                       5              4.5

         M3.5 x 7.5 sems               7.8

                                                      3

         70 max.                                      1.3            35.4

                                       Two, 4.5 dia.

                                       holes

         4

                            40±0.2                                   19

                            50 max.                                  20.3

                                                                     21.5 max.

                                                                                                                                      7
                                                                                                                                                        H2C

Track Mounting/Front Connecting Socket

P2CF-11                                              3                     4.5

                         Eleven,           7.8

                         M3.5 x 7.5 sems

                                                                                    Terminal Arrangement/

                 70 max.                                                   35.4     Internal Connections

                                           Two, 4.5  dia.                           (Top View)                                Surface Mounting Holes

                                           holes

                                                                                                                              Two, 4.5 dia. or two, M4

                    4

                                  50 max.

                                                             31.2 max.                                                        40±0.2

P2CF-11-E (Finger Safe Terminal Type)

Conforming to VDE0106/P100

                 Eleven,

                 M3.5 x 7.5 sems           7.8               5                 4.5

                                                          3

                                                     1.2                   35.4

                 70 max.

                                           Two, 4.5  dia.

                                           holes

                 4

                                  40±0.2                              30

                                  50 max.

                                                                31.2 max.

Back Connecting Socket

P3G-08                            27 dia.                                           Terminal Arrangement/

                                                                                    Internal Connections

                                                                                    (Bottom View)

                    45

                                  45                 4.9        17

P3GA-11                                                                             Terminal Arrangement/

                                  27 dia.                                           Internal Connections

                                                                                    (Bottom View)

                    45                                                    25.6

                                  45                 4.5                  6.2

                                                                16.3

Finger Safe Terminal Cover

Conforming to VDE0106/P100

Y92A-48G                                                                            Twelve,  6.4  dia. holes

(Attachment for P3G-08/

P3GA-11 Socket)

                                                                      34                          47.7 x 47.7        48 x 48

                                                                                                  16.5  24.6   27.6

                                                                                                                                                             8
                                                                                                                                                                     H2C

Mounting Track

PFP-100N, PFP-50N                                                                 PFP-100N2

                                                                                                                                                           16

                                                      7.3±0.15

4.5                                                                               4.5

                                                          35±0.3       27±0.15                                                 35±0.3         27     24        29.2

     15  25      25                   25      25                                        15  25      25         25      25  15                        1         1.5

             10                           10      15 (5)               1                        10      1,000      10

                     1,000 (500)                  (see note)

                     (see note)

Note:    The value shown in parentheses are for the

         PFP-50N.

End Plate                                                                         Spacer                                               16

PFP-M                                                             10              PFP-S                                5             12

                                                                  6.2       1.8

                                                                  1

                                  50                                        35.5  35.3                                         44.3                  34.8

                                                                       1.8

                                      11.5                        1.3

                                              10  M4 x 8          4.8

                                                  pan head                                                                           16.5

                                                  screw

Time Setting Ring                                                                 Protective Cover

Y92A-Y1                                                                           Y92A-48B

The time setting ring locks the time setting knob to                                    The protective cover shields the front panel, particu-

store the set time to facilitate its resetting. A maximum                               larly the time setting section, from dust, dirt, and water,

of two time setting rings are connectable per timer.                                    as well as prevents the set value from being altered

                                                                                        due to accidental contact with the time setting knob.

Timer Hold-down Clips

Y92H-2                                        Y92H-1

(for PF085A/PF113A                            (for PL08/PL11

Connecting Socket)                            Connecting Socket)

                                                                                                                                                                          9
                                                                                                                                             H2C

Safety Precautions

Refer to Safety Precautions for All Timers.

                             !CAUTION                                        ■ Precautions for Correct Use

This may occasionally cause electric shock, fire, or malfunction.            How to Change the Time Range

Never disassemble, repair, or modify the H2C.

This may occasionally cause electric shock, fire, or malfunction.            Change the time range by turning the knob clockwise using a flat-

Do not allow metal fragments or lead wire scraps to fall inside the          blade screwdriver or an Allen wrench. There are five possible

H2C.                                                                         settings. The selected time is displayed in the time range display

                                                                             window above the knob.

■ Precautions for Safe Use

Observe the following items to ensure the safe use of this product.

                                                                                                                                 Time range

Environmental Precautions                                                                                                        display window

•  Store the H2C within the specified ratings. If the H2C has been

   stored at temperatures –10°C or lower, let it stand for 3 hours or

   longer at room temperature before turning ON the power supply.                                               Groove for   Hex. hole for

•  Use the H2C within the specified ratings for operating temperature                                           flat-blade   Allen wrench

   and humidity.                                                                                                screwdriver

•  Do not operate the H2C in locations subject to sudden or extreme          Do not change the time range while the timer is in operation.

   changes in temperature, or locations where high humidity may              How to Select Power Frequency

   result in condensation.

•  Do not use the H2C in locations subject to vibrations or shock.           Before using the timer, set the frequency selector located at the   rear

   Extended use in such locations may result in damage due to stress.        panel to the proper power frequency (50 to 60 Hz).

•  Do not use the H2C in locations subject to excessive dust,

   corrosive gas, or direct sunlight.

•  Install the H2C well away from any sources of static electricity, such

   as pipes transporting molding materials, powders, or liquids.

•  The H2C is not waterproof or oil resistant.                                                                               50 Hz

   Do not use it in locations subject to water or oil.

•  The life expectancy of internal components may be reduced if the

   H2C is mounted side-by-side.                                                                                                     60 Hz

•  Do not use organic solvents (such as paint thinner or benzine),

   strong alkaline, or strong acids because they will damage the

   external finish.

Usage Precautions                                                            How to Mount the Timer on Mounting

•  Install a switch or circuit breaker that allows the operator to           Track

   immediately turn OFF the power, and label it to clearly indicate its

   function.                                                                 Mounting

•  Be sure to wire the terminals correctly.                                  First hook portion A of the timer to the mounting track, then press the

•  Do not install input lines in the same duct or conduit as power           timer in direction B.

   supply or other high-voltage lines. Doing so may result in

   malfunction due to noise. Separate the input lines from high-             Dismounting

   voltage lines.

•  Internal elements may be destroyed if a voltage outside the rated         Pull out portion C with a round-blade screwdriver and remove the

   voltage is applied.                                                       timer from the mounting track.

•  Maintain voltage fluctuations in the power supply within the

   specified range.

•  Use a switch, relay, or other contact so that the rated power supply                                      A

   voltage will be reached within 0.1 s. If the power supply voltage is

   not reached quickly enough, the H2C may malfunction or outputs

   may be unstable.

•  Leaving the H2C with outputs ON at a high temperature for a long

   time may hasten the degradation of internal parts (such as

   electrolytic capacitors). Therefore, use the H2C in combination with                                                                      C

   relays and avoid leaving the H2C for more than 1 month with an                                   B

   output turned ON.

                                                                             Electrical Set

                 X2/b   T/a      X1/a            X1/a                        The motor and clutch do not need to be reset simultaneously.

                                                                             Use the voltage applied to the clutch for resetting with the H2C-@R.

              T         X1                   X2         X  Auxiliary relay   Do not allow power to be continuously applied to the motor and

                                                           (e.g., MY Relay)  clutch for extended periods of time.

                                                                                                                                                       10
                                                                                                                              H2C

Others

Do not turn the operation time setting knob beyond the range of the

scale. To achieve higher accuracy in setting, measure the operation

time while turning the operation time setting knob.

The deviation and setting error for the operation time shows the

percent of FS. The absolute value of the deviation and setting error

will not change even if the set time is changed. The time

specifications should therefore be selected to use the operation time

as close to FS as possible.

At high temperatures, the operation voltage will be 90% or less if

voltage is applied continuously after timeout. Be sure to keep the

voltage within the allowable voltage fluctuation range.

Precautions for EN61812-1

The H2C (except for H2C-F@) as a built-in timer conforms to

EN61812-1, provided that the following conditions are satisfied.

Handling

Before dismounting the H2C from the Socket, make sure that no

voltage is imposed on any terminal of the H2C.

Applicable Sockets: P2CF-@@, P2CF-@@-E, PF085A, PL@@.

Wiring

Basic insulation is ensured between the motor circuit, clutch circuit,

and control output circuit. (However, the H2C-8 motor circuit and

clutch circuit use the same input.) Basic insulation is also ensured

between the output circuits of models with instantaneous output.

Basic insulation: Overvoltage category III, pollution degree 1 (See

note.)

Operating parts: Reinforced insulation (double insulation)

(with a clearance of 5.5 mm and a creepage distance of 5.5 mm at

240 VAC)

Output parts: Basic insulation

(with a clearance of 3.0 mm and a creepage distance of 3.0 mm at

240 VAC)

Note: Overvoltage category II, pollution degree 1 if the Timer is

        mounted to the PL11 Socket.

          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                              11
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)

from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.                     ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.                                OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS

IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products.   This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given.             This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

•  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

•  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

   safety equipment, and installations subject to separate industry or government regulations.

•  Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the products may be changed without any notice.     When in doubt, special model numbers may be assigned to fix or

establish key specifications for your application on your request.  Please consult with your OMRON representative at any time to confirm actual

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent               the

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

                                                                                                                                                               2008.11

                                                      In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/

                                                                                                          (c)Copyright OMRON Corporation 2008 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

   H2C-8-AC120-A  H2C-8 AC200/220 A  H2C-8-AC240-A  H2C-8-AC240-B   H2C-8-AC240-C   H2C-8 AC24 B  H2C-8R

AC100/110 B  H2C-8R AC100/110 C   H2C-8R-AC120-A    H2C-8R-AC120-B  H2C-8R-AC120-C  H2C-8R AC200/220 C

H2C-8R AC240 A    H2C-8R-AC240-B  H2C-8R-AC240-C    H2C-8R AC24 A   H2C-AC110-B  H2C-AC110-C    H2C-AC120

A  H2C-AC120-B    H2C-AC240-B    H2C-AC24-B  H2C-F-AC120-C  H2C-F-AC24-B  H2C-R-AC120-B  H2C-R-AC220-A

H2C-R-AC220-B     H2C-R AC240 B  H2C-R-S AC24 A  H2C-S AC110 C  H2C-S AC220 C    H2C-S AC240 A  H2C-S

AC24 B  H2C-SB-AC110    H2C AC240 A  H2C AC24 A   H2C-R-S AC24 B

小广播

H2C-8R-AC120-B器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved