DRAM 16M x 18 (288Meg) LLDRAM II Common I/O

参数
产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
GSI Technology
产品种类:
Product Category:
DRAM
RoHS:YES
类型:
Type:
SDRAM - DDR1
Data Bus Width:18 bit
Organization:16 M x 18
封装 / 箱体:
Package / Case:
uBGA-144
Memory Size:288 Mbit
Maximum Clock Frequency:400 MHz
Access Time:20 ns
电源电压-最大:
Supply Voltage - Max:
1.9 V
电源电压-最小:
Supply Voltage - Min:
1.7 V
Supply Current - Max:410 mA
最小工作温度:
Minimum Operating Temperature:
- 40 C
最大工作温度:
Maximum Operating Temperature:
+ 95 C
封装:
Packaging:
Tray
商标:
Brand:
GSI Technology
安装风格:
Mounting Style:
SMD/SMT
Moisture Sensitive:Yes
产品类型:
Product Type:
DRAM
工厂包装数量:
Factory Pack Quantity:
18
子类别:
Subcategory:
Memory & Data Storage
单位重量:
Unit Weight:
0.423288 oz

GS4288C18GL-25I器件文档内容

                                                                                                                       GS4288C09/18/36L

144-Ball BGA                                 32M x 9, 16M x 18, 8M x 36                                               533 MHz–300 MHz

Commercial Temp              288Mb CIO Low Latency DRAM (LLDRAM) II                                                       2.5 V VEXT

Industrial Temp                                                                                                           1.8 V VDD

                                                                                                                       1.5 V or 1.8 V VDDQ

Features                                                         Introduction

•  Pin- and function-compatible with Micron RLDRAM® II           The GSI Technology 288Mb Low Latency DRAM

•  533 MHz DDR operation (1.067Gb/s/pin data rate)               (LLDRAM) II is a high speed memory device designed for

•  38.4 Gb/s peak bandwidth (x36 at 533 MHz clock frequency)     high address rate data processing typically found in networking

•  8M x 36, 16M x 18, and 32M x 9 organizations available        and telecommunications applications. The 8-bank architecture

•  8 internal banks for concurrent operation and maximum         and low tRC allows access rates formerly only found in

   bandwidth                                                     SRAMs.

•  Reduced cycle time (15 ns at 533 MHz)

•  Address Multiplexing (Nonmultiplexed address option           The Double Data Rate (DDR) I/O interface provides high

   available)                                                    bandwidth data transfers, clocking out two beats of data per

•  SRAM-type interface                                           clock cycle at the I/O balls. Source-synchronous clocking can

•  Programmable Read Latency (RL), row cycle time, and burst     be implemented on the host device with the provided free-

   sequence length                                               running data output clock.

•  Balanced Read and Write Latencies in order to optimize data

   bus utilization                                               Commands, addresses, and control signals are single data rate

•  Data mask for Write commands                                  signals clocked in by the True differential input clock

•  Differential input clocks (CK, CK)                            transition, while input data is clocked in on both crossings of

•  Differential input data clocks (DKx, DKx)                     the input data clock(s).

•  On-chip DLL generates CK edge-aligned data and output

   data clock signals                                            Read and Write data transfers always in short bursts. The burst

•  Data valid signal (QVLD)                                      length is programmable to 2, 4 or 8 by setting the Mode

•  32 ms refresh (8K refresh for each bank; 64K refresh          Register.

   command must be issued in total each 32 ms)

•  144-ball BGA package                                         The device is supplied with 2.5 V VEXT and 1.8 V VDD for the

•  HSTL I/O (1.5 V or 1.8 V nominal)                             core, and 1.5 V or 1.8 V for the HSTL output drivers.

•  25–60 matched impedance outputs

•  2.5 V VEXT, 1.8 V VDD, 1.5 V or 1.8 V VDDQ I/O                Internally generated row addresses facilitate bank-scheduled

•  On-die termination (ODT) RTT                                  refresh.

•  Commerical and Industrial Temperature

   Commercial (+0° TC +95°C)                                The device is delivered in an efficent BGA 144-ball package.

   Industrial (–40° TC +95°C)

Rev: 1.03 7/2014                                           1/62                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                   GS4288C09/18/36L

                        32M x 9 Mb Ball Assignments—144-Ball BGA—Top View

        1         2     3     4     5                                 6  7  8                                          9           10   11    12

    A   VREF      VSS   VEXT  VSS                                                                                      VSS   VEXT       TMS   TCK

    B   VDD       DNU3  DNU3  VSS                                                                                      VSS   DQ0        DNU3  VDD

    C   VTT       DNU3  DNU3  VDDQ                                                                                     VDDQ  DQ1        DNU3  VTT

    D   A221      DNU3  DNU3  VSS                                                                                      VSS   QK0        QK0   VSS

    E   A211      DNU3  DNU3  VDDQ                                                                                     VDDQ  DQ2        DNU3  A20

    F   A5        DNU3  DNU3  VSS                                                                                      VSS   DQ3        DNU3  QVLD

    G   A8        A6    A7    VDD                                                                                      VDD         A2   A1    A0

    H   B2        A9    VSS   VSS                                                                                      VSS         VSS  A4    A3

    J   NF2       NF2   VDD   VDD                                                                                      VDD         VDD  B0    CK

    K   DK        DK    VDD   VDD                                                                                      VDD         VDD  B1    CK

    L   REF       CS    VSS   VSS                                                                                      VSS         VSS  A14   A13

    M   WE        A16   A17   VDD                                                                                      VDD         A12  A11   A10

    N   A18       DNU3  DNU3  VSS                                                                                      VSS   DQ4        DNU3  A19

    P   A15       DNU3  DNU3  VDDQ                                                                                     VDDQ  DQ5        DNU3  DM

    R   VSS       DNU3  DNU3  VSS                                                                                      VSS   DQ6        DNU3  VSS

    T   VTT       DNU3  DNU3  VDDQ                                                                                     VDDQ  DQ7        DNU3  VTT

    U   VDD       DNU3  DNU3  VSS                                                                                      VSS   DQ8        DNU3  VDD

    V   VREF      ZQ    VEXT  VSS                                                                                      VSS   VEXT       TDO   TDI

Notes:

1.     Reserved for future use. This pin may be connected to ground.

2.     No function. This pin may have parasitic characteristics of a clock input signal. It may be connected to              GND.

3.     Do not use. This pin may have parasitic characteristics of an I/O. It may be connected to GND.

Rev: 1.03 7/2014                       2/62                                                                                             © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                   GS4288C09/18/36L

                        16M x 18 Ball Assignments—144-Ball BGA—Top View

        1         2     3     4     5                              6  7  8                                             9           10      11       12

    A   VREF      VSS   VEXT  VSS                                                                                      VSS   VEXT          TMS      TCK

    B   VDD       DNU4  DQ4   VSS                                                                                      VSS   DQ0           DNU4     VDD

    C   VTT       DNU4  DQ5   VDDQ                                                                                     VDDQ  DQ1           DNU4     VTT

    D   A221      DNU4  DQ6   VSS                                                                                      VSS   QK0           QK0      VSS

    E   A211      DNU4  DQ7   VDDQ                                                                                     VDDQ  DQ2           DNU4     A202

    F   A5        DNU4  DQ8   VSS                                                                                      VSS   DQ3           DNU4     QVLD

    G   A8        A6    A7    VDD                                                                                      VDD         A2      A1       A0

    H   B2        A9    VSS   VSS                                                                                      VSS         VSS     A4       A3

    J   NF3       NF3   VDD   VDD                                                                                      VDD         VDD     B0       CK

    K   DK        DK    VDD   VDD                                                                                      VDD         VDD     B1       CK

    L   REF       CS    VSS   VSS                                                                                      VSS         VSS     A14      A13

    M   WE        A16   A17   VDD                                                                                      VDD         A12     A11      A10

    N   A18       DNU4  DQ14  VSS                                                                                      VSS   DQ9           DNU4     A19

    P   A15       DNU4  DQ15  VDDQ                                                                                     VDDQ  DQ10          DNU4     DM

    R   VSS       QK1   QK1   VSS                                                                                      VSS   DQ11          DNU4     VSS

    T   VTT       DNU4  DQ16  VDDQ                                                                                     VDDQ  DQ12          DNU4     VTT

    U   VDD       DNU4  DQ17  VSS                                                                                      VSS   DQ13          DNU4     VDD

    V   VREF      ZQ    VEXT  VSS                                                                                      VSS   VEXT          TDO      TDI

Notes:

1.     Reserved for future use. This pin may be connected to GND.

2.     Reserved for future use. This pin may have parasitic characteristics of an address input signal. It may               be connected  to GND.

3.     No function. This pin may have parasitic characteristics of a clock input signal. It may be connected to              GND.

4.     Do not use. This pin may have parasitic characteristics of an I/O. It may be connected to GND.

Rev: 1.03 7/2014                       3/62                                                                                             © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                             GS4288C09/18/36L

                                  8M x  36 Ball  Assignments—144-Ball      BGA—Top                                    View

        1            2            3     4        5                   6  7  8                                           9     10    11    12

    A   VREF         VSS          VEXT  VSS                                                                            VSS   VEXT  TMS   TCK

    B   VDD          DQ8          DQ9   VSS                                                                            VSS   DQ1   DQ0   VDD

    C   VTT          DQ10         DQ11  VDDQ                                                                           VDDQ  DQ3   DQ2   VTT

    D   A221         DQ12         DQ13  VSS                                                                            VSS   QK0   QK0   VSS

    E   A211         DQ14         DQ15  VDDQ                                                                           VDDQ  DQ5   DQ4   A202

    F   A5           DQ16         DQ17  VSS                                                                            VSS   DQ7   DQ6   QVLD

    G   A8           A6           A7    VDD                                                                            VDD   A2    A1    A0

    H   B2           A9           VSS   VSS                                                                            VSS   VSS   A4    A3

    J   DK0          DK0          VDD   VDD                                                                            VDD   VDD   B0    CK

    K   DK1          DK1          VDD   VDD                                                                            VDD   VDD   B1    CK

    L   REF          CS           VSS   VSS                                                                            VSS   VSS   A14   A13

    M   WE           A16          A17   VDD                                                                            VDD   A12   A11   A10

    N   A18          DQ24         DQ25  VSS                                                                            VSS   DQ35  DQ34  A192

    P   A15          DQ22         DQ23  VDDQ                                                                           VDDQ  DQ33  DQ32  DM

    R   VSS          QK1          QK1   VSS                                                                            VSS   DQ31  DQ30  VSS

    T   VTT          DQ20         DQ21  VDDQ                                                                           VDDQ  DQ29  DQ28  VTT

    U   VDD          DQ18         DQ19  VSS                                                                            VSS   DQ27  DQ26  VDD

    V   VREF         ZQ           VEXT  VSS                                                                            VSS   VEXT  TDO   TDI

Notes:

1.     Reserved for  future use.  This pin may be connected to GND.

2.     Reserved for  future use.  This pin may have parasitic characteristics of an address pin. It may be connected to GND.

Rev: 1.03 7/2014                                    4/62                                                                           © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Ball  Descriptions

      Symbol        Type                                                 Description

                               Address Inputs—A0–A20 define the row and column addresses for Read and Write Operations. During

      A0–A20        Input      a Mode Register Set (MRS), the address inputs define the register settings. They are sampled at the

                               rising edge of CK.

      BA0–B2        Input      Bank Address inputs—Select to which internal bank a command is being applied.

      CK, CK        Input      Input Clock—CK and CK are differential input clocks. Addresses and commands are latched on the

                               rising edge of CK. CK is ideally 180º out of phase with CK.

      CS            Input      Chip Select—CS enables the command decoder when Low and disables it when High. When the

                               command decoder is disabled, new commands are ignored, but internal operations continue.

      DQ0–DQ35      Input      Data Input—The DQ signals form the 36-bit data bus. During Read commands, the data is referenced to

                               both edges of QKx. During Write commands, the data is sampled at both edges of DK.

                               Input Data Clock—DK and DK are the differential input data clocks. All input data is referenced to both

      DK, DK        Input      edges of DK. DK is ideally 180º out of phase with DK. For the x36 device, DQ0– DQ17 are referenced to

                               DK0 and DK0 and DQ18–DQ35 are referenced to DK1 and DK1. For the x9 and x18 devices, all DQs

                               are referenced to DK and DK. All DKx and DKx pins must always be supplied to the device.

                               Input Data Mask—The DM signal is the input mask signal for Write data. Input data is masked when DM

      DM            Input      is sampled High. DM is sampled on both edges of DK (DK1 for the x36 configuration). Tie signal to

                               ground if not used.

      TCK           Input      IEEE 1149.1 clock input—This ball must be tied to VSS if the JTAG function is not used.

      TMS, TDI      Input      IEEE 1149.1 test inputs—These balls may be left as no connects if the JTAG function is not used.

      WE, REF       Input      Command Inputs—Sampled at the positive edge of CK, WE and REF define (together with CS) the

                               command to be executed.

      VREF          Input      Input Reference Voltage—Nominally VDDQ/2. Provides a reference voltage for the input buffers.

                               External Impedance (25–60)—This signal is used to tune the device outputs to the system data bus

                               impedance. DQ output impedance is set to 0.2 * RQ, where RQ is a resistor from this signal to ground.

      ZQ            Reference  Connecting ZQ to GND invokes the Minimum Impedance mode. Connecting ZQ to VDD invokes the

                               Maximum Impedance mode. Refer to the Mode Register Definition diagrams (Mode Register Bit 8 (M8))

                               to activate or deactivate this function.

                               Output Data Clocks—QKx and QKx are opposite polarity, output data clocks. They are free running,

                               and during Reads, are edge-aligned with data output from the LLDRAM II. QKx is ideally 180º out of

      QKx, QKx      Output     phase with QKx. For the x36 device, QK0 and QK0 are aligned with DQ0–DQ17, and QK1 and QK1 are

                               aligned with DQ18–DQ35. For the x18 device, QK0 and QK0 are aligned with DQ0–DQ8, while QK1 and

                               QK1 are aligned with Q9–Q17. For the x9 device, all DQs are aligned with QK0 and QK0.

Rev: 1.03 7/2014                                    5/62                                                               © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Ball  Descriptions  (Continued)

      Symbol        Type                                                       Description

      QVLD          Output        Data Valid—The QVLD pin indicates valid output data. QVLD is edge-aligned with QKx and QKx.

      TDO           Output        IEEE 1149.1 Test Output—JTAG output. This ball may be left as no connect if the JTAG function is not

                                  used.

      VDD           Supply        Power Supply—Nominally, 1.8 V. See the DC Electrical Characteristics and Operating Conditions

                                  section for range.

      VDDQ          Supply        DQ Power Supply—Nominally, 1.5 V or 1.8 V. Isolated on the device for improved noise immunity. See

                                  the DC Electrical Characteristics and Operating Conditions section for range.

      VEXT          Supply        Power Supply—Nominally, 2.5 V. See the DC Electrical Characteristics and Operating Conditions

                                  section for range.

      VSS           Supply        Ground

      VTT           —             Power Supply—Isolated termination supply. Nominally, VDDQ/2. See the DC Electrical Characteristics

                                  and Operating Conditions section for range.

      A21, A22      —             Reserved for Future Use—This signal is not connected and may be connected to ground.

      DNU           —             Do Not Use—These balls may be connected to ground.

      NF            —             No Function—These balls can be connected to ground.

Operations

Initialization

A specific power-up and initialization sequence must be observed. Other sequences may result in undefined operations or

permanent damage to the device.

Power-up:

      1. Apply power (VEXT, VDD, VDDQ, VREF, VTT) . Start clock after the supply voltages are stable. Apply VDD and VEXT before or

      at the same time as VDDQ1.  Apply VDDQ before or at the same time as VREF and VTT. The chip starts internal initlization

      only after both voltages approach their nominal levels. CK/CK must meet VID(DC) prior to being applied2. Apply only

      NOP commands to start. Ensuring CK/CK meet VID(DC) while loading NOP commands guarantees that the LLDRAM II

      will not receive damaging commands during initialization.

      2. Idle with continuing NOP commands for 200s (MIN).

      3. Issue three or more consecutive MRS commands: two or more dummies plus one valid MRS. The consecutive MRS

      commands will reset internal logic of the LLDRAM II. tMRSC does not need to be met between these consecutive

      commands. Address pins should be held Low during the dummy MRS commands.

Rev: 1.03 7/2014                                      6/62                                                             © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

        4. tMRSC after the valid MRS, issues an AUTO REFRESH command to all 8 banks in any order (along with 1024 NOP

        commands) prior to normal operation. As always, tRC must be met between any AUTO REFRESH and any subsequent

        valid command to the same bank.

Notes:

1.  It is possible to apply VDDQ before VDD. However, when doing this, the DQs, DM, and all other pins with an output driver, will

    go High instead of tri-stating. These pins will remain High until VDD is at the same level as VDDQ. Care should be taken to

    avoid bus conflicts during this period.

2.  If VID(DC) on CK/CK can not be met prior to being applied to the LLDRAM II, placing a large external resistor from CS to VDD

    is a viable option for ensuring the command bus does not receive unwanted commands during this unspecified state.

Rev: 1.03 7/2014                             7/62                                                                      © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                        GS4288C09/18/36L

                                                  Power–Up Initialization Sequence

    VEXT

    VDD

    VDDQ

    VREF

    VTT

                              200us Min                Mode Initialization           tMRSC                             Refresh       1024 Cycles NOP Cycles Min
                                                                                                                       All Banks(5)

                   tCK

             tCKH

    CK                  tCKL

    CK

                        tDKL

                   tDK

             tDKH

    DK

    DK

    Command             NOP   NOP                 MRS  MRS                  MRS      NOP    AREF                                AREF    NOP                      AC

    ADDR                                 CODE(1,2)     CODE(1,2)            CODE(2)                                                                              ADDR

    BA                                                                                      Bank 0                              Bank 7                           Valid

    DM

    DQ

Notes:

1.  Recommend all address pins held Low during dummy MRS commands.

2.  A10–A17 must be Low.

3.  DLL must be reset if tCK or VDD are changed.

4.  CK and CK must be separated at all times to prevent bogus commands from being issued.

5.  The sequence of the eight AUTO REFRESH commands (with respect to the 1024 NOP commands) does not matter. As is required for any operation,

    tRC must be met between an AUTO REFRESH command and a subsequent VALID command to the same bank.

Rev: 1.03 7/2014                                            8/62                                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

                  Power–Up Initialization Flow Chart

                  Step

                  1           VDD and VEXT ramp

                  2           VDDQ ramp                                                                                Voltage rails can
                                                                                                                       be applied
                                                                                                                       simultaneously

                  3           Apply VREF and VTT

                  4     Apply stable CK/CK and DK/DK

                  5           Wait at least 200s

                  6     Issue MRS command—A10–A17 must be Low

                                                                                                                       MRS commands
                                                                                                                       must be on
                  7     Issue MRS command—A10–A17 must be Low                                                          consecutive

                                                                                                                       clock cycles

                  8     Desired load mode register with A10–A17 Low

                  9     Assert NOP for tMRSC

                  10    Issue AUTO REFRESH to bank 0

                  11    Issue AUTO REFRESH to bank 1

                  12    Issue AUTO REFRESH to bank 2

                  13    Issue AUTO REFRESH to bank 3

                  14    Issue AUTO REFRESH to bank 4

                  15    Issue AUTO REFRESH to bank 5

                  16    Issue AUTO REFRESH to bank 6

                  17    Issue AUTO REFRESH to bank 7

                  18    Wait 1024 NOP commands*

                  19          Valid command

*Note:

The sequence of the eight AUTO REFRESH commands (with respect to the 1024 NOP commands) does not matter. As is required for any

operation, tRC must be met between an AUTO REFRESH command and a subsequent VALID command to the same bank.

Rev: 1.03 7/2014        9/62                                                                                                              © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

DLL Reset

Mode Register Bit 7 (M7) selects DLL Reset as is shown in the Mode Register Definition tables. The default setting for M7 is Low,

whereby the DLL is disabled. Once M7 is set High, 1024 cycles (5s at 200 MHz) are needed before a Read command can be

issued. The delay allows the internal clock to be synchronized with the external clock. Failing to wait for synchronization to occur

may result in a violation of the tCKQK parameter. A reset of the DLL is necessary if tCK or VDD is changed after the DLL has

already been enabled. To reset the DLL, set M7 is Low. After waiting tMRSC, an MRS command should be issued to set M7 High.

1024 clock cycles must pass before loading the next Read command.

Driver Impedance Mapping

The LLDRAM II is equipped with programmable impedance output buffers. Setting Mode Register Bit 8 (M8) High during the

MRS command activates the feature. Programmable impedance output buffers allow the user to match the driver impedance to the

PCB trace impedance. To adjust the impedance, an external resistor (RQ) is connected between the ZQ ball and VSS. The value of

the resistor must be five times the desired impedance (e.g., a 300 resistor produces an output impedance of 60). RQ values of

125–300 are supported, allowing an output impedance range of 25–60 (+/- 15 %).

The drive impedance of uncompensated output transistors can change over time due to changes in supply voltage and die

temperature. When drive impedance control is enabled in the MRS, the value of RQ is periodically sampled and any needed

impedance update is made automatically. Updates do not affect normal device operation or signal timing.

When Bit M8 is set Low during the MRS command, the output compensation circuits are still active but reference an internal

resistance reference. The internal reference is imprecise and subject to temperature and voltage variations so output buffers are set

to a nominal output impedance of 50, but are subject to a ±30 percent variance over the Commercial temperature range of the

device.

Rev: 1.03 7/2014          10/62                                                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                              GS4288C09/18/36L

On–Die Termination (ODT)

Mode Register Bit 9 (M9) set to 1 during an MRS command enables ODT. With ODT on, the DQs and DM are terminated to VTT

with a resistance, RTT. Command, address, QVLD, and clock signals are not terminated. The diagram below shows the equivalent

circuit of a DQ receiver with ODT. When a tri-stated DQ begins to drive, the ODT function is briefly switched off. When a DQ

stops driving at the end of a data transfer, ODT is switched back on. Two-state DM pin never deactivates ODT.

On–Die Termination DC Parameters

        Description       Symbol                 Min               Max                                                 Units  Notes

    Termination Voltage   VTT                    0.95 * VREF       1.05 * VREF                                         V      1, 2

    On–Die Termination    RTT                    125               185                                                       3

Notes:

1.  All voltages referenced to VSS (GND).

2.  VTT is expected to be set equal to VREF and must track variations in the DC level of VREF.

3.  The RTT value is measured at 95°C TC.

                                           On–Die Termination–Equivalent Circuit

                                                      VTT

                                                              SW

                                                              RTT

                                                                   Receiver

                                           DQ

                                           VREF

Rev: 1.03 7/2014                                 11/62                                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                     GS4288C09/18/36L

                          Read     NOP  Read     On-Die Termination Burst        Length           2,  Configuration 1

           T0                  T1            T2        T3               T4                T5                            T6                T7          T8

CK

CK

CMD   RD                  NOP           RD        NOP              NOP               NOP                  NOP                        NOP         NOP

ADDR  A                                 A

BA    BA0                               BA2

                                        RL = 4

QKx

QKx

QVLD

DQ                                                                          Q0a      Q0b                                    Q2a      Q2b

ODT                                ODT ON                                   ODT OFF               ODT ON                    ODT OFF              ODT ON

                               Read-Write On-Die  Termination Burst Length                    2,  Configuration 1

           T0                  T1            T2        T3               T4                T5                            T6                T7          T8

CK

CK

CMD   RD                  WT            NOP       NOP              NOP               NOP                  NOP                        NOP         NOP

ADDR  A                   A

BA    BA0                 BA1

                                                           WL = 5

DK

DK

DQ                                                                          Q0a      Q0b                  D1a               D1b

                                        RL = 4

QKx

QKx

QVLD

ODT                                ODT ON                                   ODT OFF                                              ODT ON

Rev: 1.03 7/2014                                           12/62                                                                              ©  2011, GSI  Technology

Specifications cited are  subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                    GS4288C09/18/36L

                               Read  Burst On-die  Termination Burst Length               2, Configuration                       1

           T0                  T1            T2         T3              T4            T5                                T6               T7       T8

CK

CK

CMD   RD                  RD         RD            NOP             NOP           NOP               NOP                              NOP      NOP

ADDR  A                   A          A

BA    BA0                 BA1        BA2

                                     RL = 4

QKx

QKx

QVLD

DQ                                                                          Q0a  Q0b      Q1a      Q1b                      Q2a     Q2b

ODT                                  ODT ON                                               ODT OFF                                            ODT ON

Rev: 1.03 7/2014                                            13/62                                                                            © 2011, GSI Technology

Specifications cited are  subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                              GS4288C09/18/36L

Commands

Valid control commands are listed below. Any input commands not shown are illegal or reserved. All inputs must meet specified

setup and hold times around the true crossing of CK.

Description of Commands

    Command                                                             Description                                                    Notes

                  The NOP command is used to perform a no operation to the LLDRAM II, which essentially deselects the

    DSEL/NOP      chip. Use the NOP command to prevent unwanted commands from being registered during idle or wait                     1

                  states. Operations already in progress are not affected. Output values depend on command history.

                  The Mode Register is set via the address inputs A0–A17. See the Mode Register Definition diagrams for

    MRS           further information. The MRS command can only be issued when all banks are idle and no bursts are in                 —

                  progress.

    READ          The Read command is used to initiate a burst read access to a bank. The value on the BA0–BA2 inputs                  2

                  selects the bank, and the address provided on inputs A0–An selects the data location within the bank.

                  The Write command is used to initiate a burst write access to a bank. The value on the BA0–BA2 inputs

                  selects the bank, and the address provided on inputs A0–An selects the data location within the bank.

    WRITE         Input data appearing on the DQ is written to the memory array subject to the DM input logic level                    2

                  appearing coincident with the data. If the DM signal is registered Low, the corresponding data will be

                  written to memory. If the DM signal is registered High, the corresponding data inputs will be ignored (that

                  is, this part of the data word will not be written).

                  The AREF command is used during normal operation of the LLDRAM II to refresh the memory content

                  of a bank. The command is non-persistent, so it must be issued each time a refresh is required. The

    AREF          value on the BA0–BA2 inputs selects the bank. The refresh address is generated by an internal refresh                —

                  controller, effectively making each address bit a “Don’t Care” during the AREF command.

                  See the Auto Refresh section for more details.

Notes:

1.  When the chip is deselected, internal NOP commands are generated and no commands are accepted.

2.  For the value of “n”, see Address Widths at Different Burst Lengths table.

Command Table

              Operation           Command             CS                        WE   REF                               A0–An  BA0–BA2     Notes

    Device Deselect/No Operation  DSEL/NOP                        H             X    X                                 X       X              1

                  MRS             MRS                             L             L    L                                 CODE    X          1, 3

                  Read            READ                            L             H    H                                 A       BA         1, 2

                  Write           WRITE                           L             L    H                                 A       BA         1, 2

           Auto Refresh           AREF                            L             H    L                                 X       BA             1

Notes:

1.  X= Don’t Care; H = Logic High; L = Logic Low; A = Valid Address; BA = Valid Bank Address.

2.  For the value of “n”, see Address Widths at Different Burst Lengths table.

3.  Only A0–A17 are used for the MRS command.

Rev: 1.03 7/2014                                      14/62                                                                    © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

                                 State Diagram

                                 Initialization

                                             Sequence

                                             DSEL/

                                             NOP

                  Write                                                                                                Read

                  MRS                                                                                                  AREF

                         Notes:

                         Automatic Sequence

                         Command Sequence

Rev: 1.03 7/2014                 15/62                                                                                       ©  2011,  GSI  Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Mode Register Set

Mode Register Set controls the operating modes of the memory, including configuration, burst length, test mode, and I/O options.

During an MRS command, the address inputs A0–A17 are sampled and stored in the Mode Register. Except during initialization to

force internal reset, after a valid MRS command, tMRSC must be met before any command except NOP can be issued to the

LLDRAM II. All banks must be idle and no bursts may be in progress when an MRS command is loaded.

Note: Changing the burst length configuration may scramble previously written data. A burst length change must be assumed to

invalidate all stored data.

                                      Mode Register Set

                             CK

                             CK

                             CS

                             WE

                             REF

                             Addr            CODE

                             BA(2:0)

Rev: 1.03 7/2014                      16/62                                                                            © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                       GS4288C09/18/36L

                                  Mode Register Definition in Nonmultiplexed Address Mode

                                  A17  ...     A10    A9    A8     A7       A6   A5  A4        A3  A2                  A1        A0    Address Bus

                                  17–10               9     8      7        6    5   4         3   2                   1      0        Mode Register (Mx)

                                  Reserved1           ODT   IM  DLL         NA2  AM     BL             Config

                                       On Die                                                                             M2      M1   M0  Configuration

                              M9       Termination

                                                                                                                           0        0  0   13 (default)

                              0        Off (default)                                                                       0        0  1            13

                              1           On

                                                                                                                           0        1  0            2

                                                                                                                           0        1  1            3

    M8  Drive Impedance                   M7          DLL Reset                                                            1        0  0            43

    0   Internal 505 (default)             0         DLL reset4 (default)

    1   External (ZQ)                                                                                                      1        0  1            5

                                            1         DLL enabled                                                          1        1  0   Reserved

                                                                                                                           1        1  1   Reserved

                  M5                   Address MUX

                                                                                         M4        M3                     Burst

                         0        Nonmulitplexed (default)                                                                Length

                         1             Multiplexed                                          0      0                   2 (default)

                                                                                            0      1                       4

                                                                                            1      0                       8

                                                                                            1      1                   Reserved

Notes:

1.  A10–A17 must be set to zero; A18–An = “Don’t Care”.

2.  A6 not used in MRS.

3.  BL = 8 is not available.

4.  DLL RESET turns the DLL off.

5.  +/–30% over rated temperature range.

Rev: 1.03 7/2014                                                17/62                                                                  © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                              GS4288C09/18/36L

Configuration Tables

The relationship between cycle time and read/write latency is selected by the user. The configuration table below lists valid

configurations available via Mode Register bits M0, M1, and M2 and the clock frequencies supported for each setting. Write

Latency is equal to the Read Latency plus one in each configuration to reduce bus conflicts.

Cycle Time and Read/Write Latency Configuration Table

        Parameter                                      Configuration                                                                                 Units

                             12       2                3                                      42, 3                           5

        tRC                  4        6                8                                      3                               5                      tCK

        tRL                  4        6                8                                      3                               5                      tCK

        tWL                  5        7                9                                      4                               6                      tCK

    Valid Frequency Range    266–175  400–175          533–175                                200–175                         333–175                MHz

Notes:

1.  tRC < 20 ns in any configuration is only available with –18 and –24 speed grades.

2.  BL= 8 is not available.

3.  The minimum tRC is typically 3 cycles, except in the case of a Write followed by a  Read  to the same              bank.  In this instance  the  minimum

    tRC is 4 cycles.

Rev: 1.03 7/2014                         18/62                                                                                   © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                               GS4288C09/18/36L

Burst Length

Read and Write data transfers occur in bursts of 2, 4, or 8 beats. Burst Length is programmed by the user via Mode Register Bit 3

(M3) and Bit 4 (M4). The Read Burst Length diagrams illustrate the different burst lengths with respect to a Read Command.

Changes in the burst length affect the width of the address bus.

Note: Changing the burst length configuration may scramble previously written data. A burst length change must be assumed to

invalidate all stored data.

                                               Read Burst Lengths

                                                                       Example  BL=2

CK

CK

Command       READ

QKx                               RL = 5

QKx

QVLD

DQ                                                                     Q0             Q1

                                                                       Example  BL=4

CK1

CK1

Command1      READ           NOP          NOP                     NOP                 NOP           NOP                    NOP           NOP

QKx1                              RL = 5

QKx1

QVLD1

DQ1                                                                    Q0             Q1   Q2  Q3

                                                                       Example  BL=8

CK2

CK2

Command2      READ           NOP          NOP                     NOP                 NOP           NOP                    NOP           NOP

QKx2                              RL = 5

QKx2

QVLD2

DQ2                                                                    Q0             Q1   Q2  Q3                      Q4  Q5   Q6  Q7

Address Widths at Different Burst Lengths

              Burst Length                                                                 Configuration

                                               x9                                              x18                                  x36

                    2                          A0–A20                                          A0–A19                               A0–A18

                    4                          A0–A19                                          A0–A18                               A0–A17

                    8                          A0–A18                                          A0–A17                               A0–A16

Rev: 1.03 7/2014                               19/62                                                                            © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Write

Write data transfers are launched with a Write command, as shown below. A valid address must be provided during the Write

command.

During Write data transfers, each beat of incoming data is registered on crossings of DK and DK until the burst transfer is

complete. Write Latency (WL) that is always one cycle longer than the programmed Read Latency (RL), so the first valid data

registered at the first True crossing of the DK clocks WL cycles after the Write command.

A Write burst may be followed by a Read command (assuming tRC is met). At least one NOP command is required between Write

and Read commands to avoid data bus contention. The Write-to-Read timing diagrams illustrate the timing requirements for a

Write followed by a Read. Setup and hold times for incoming DQ  relative to the DK edges are specified as tDS and tDH. Input

data may be masked a High on an associated DM pin. The setup and hold times for the DM signal are tDS and tDH.W

                           Write Command

                  CK

                  CK

                  CS

                  WE

                  REF

                  Addr                                          A

                  BA(2:0)                                       BA

Rev: 1.03 7/2014           20/62                                                                                       © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                              GS4288C09/18/36L

                                                                Write Burst  Length 2,      Configuration  1

           T0                        T1              T2                 T3              T4       T5                                  T6            T7            T8

                                             RC = 4

CK

CK

CMD   WR                        WR           WR                    WR              WR       WR                                  WR            WR            WR

ADDR  A                         A            A                     A               A        A                                   A             A             A

BA    BA0                       BA1          BA2                   BA3             BA0      BA4                                 BA5           BA6           BA7

                                                         WL=5

DK

DK

DM

DQ                                                                                          D0a               D0b               D1a      D1b  D2a      D2b  D3a         D3b

                                                                Write Burst  Length 4,      Configuration  1

      T0                           T1           T2                    T3              T4       T5                                  T6            T7            T8

CK                                           RC = 4

CK

CMD   WR                        NOP          WR                    NOP             WR       NOP                                 WR            NOP           WR

ADDR       A                                 A                                     A                                            A                           A

BA    BA0                                    BA1                                   BA0                                          BA3                         BA0

                                                         WL  =  5

DK

DK

DM

DQ                                                                                          D0a            D0b                  D0c      D0d  D1a      D1b  D1c         D1d

      Rev: 1.03 7/2014                                                      21/62                                                             © 2011,  GSI  Technology

      Specifications cited are  subject  to  change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                       GS4288C09/18/36L

                                                      Write-Read      Burst Length  2, Configuration     1

           0                   1                   2               3         4           5            6                        7            8       9

                                                                      RL = 4

CK

CK

CMD   WR                  NOP                 RD              RD      NOP           NOP          NOP                      NOP          NOP     NOP

ADDR  A                                       A               A

BA    BA0                                     BA1             BA2

DK                                                    WL = 5

DK

DM

DQ                                                                                  D0a     D0b          Q1a              Q1b     Q2a  Q2b

QVLD

QKx

QKx

Rev: 1.03 7/2014                                                      22/62                                                                 © 2011, GSI Technology

Specifications cited are  subject to  change  without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                    GS4288C09/18/36L

                                                       Write-Read       Burst Length  4, Configuration       1

           T0                  T1                  T2               T3         T4          T5            T6               T7             T8            T9

                                                                                      RL = 4

CK

CK

CMD   WR                  NOP                 NOP              RD       NOP           RD            NOP                   NOP       NOP           NOP

ADDR  A                                                        A                      A

BA    BA0                                                      BA1                    BA2

                                                       WL = 5

DK

DK

DM

DQ                                                                                    D0a      D0b  D0c      D0d               Q1a  Q1b      Q1c  Q1d      Q2a

QVLD

QKx

QKx

Rev: 1.03 7/2014                                                        23/62                                                       © 2011, GSI Technology

Specifications cited are  subject to  change  without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Read

Read data transfers are launched with a Read command, as shown below. Read Addresses must provided with the Read command.

Each beat of a Read data transfer is edge-aligned with the QKx signals. After a programmable Read Latency, data is available at the

outputs. One half clock cycle prior to valid data on the read bus, the data valid signal (QVLD) is driven High. QVLD is also edge-

aligned with the QKx signals. The QK clocks are free-running.

The skew between QK and the crossing point of CK is specified as tCKQK. tQKQ0 is the skew between QK0 and the last valid data

edge generated at the DQ signals associated with QK0 (tQKQ0 is referenced to DQ0–DQ17 for the x36 configuration and DQ0–DQ8

for the x18 configuration). tQKQ1 is the skew between QK1 and the last valid data edge generated at the DQ signals associated with

QK1 (tQKQ1 is referenced to DQ18–DQ35 for the x36 and DQ9–DQ17 for the x18 configuration). tQKQx is derived at each QKx

clock edge and is not cumulative over time. tQKQ is defined as the skew between either QK differential pair and any output data edge.

At the end of a burst transfer, assuming no other commands have been initiated, output data (DQ) will go High-Z. The QVLD signal

transitions Low on the beat of a Read burst. Note that if CK/CK violates the VID(DC) specification while a Read burst is occurring,

QVLD remains High until a dummy Read command is issued. Back-to-back Read commands are possible, producing a continuous

flow of output data.

The data valid window specification is referenced to QK transitions and is defined as: tQHP – (tQKQ [MAX] + |tQKQ [MIN]|). See the

Read Data Valid Window section for illustration.

Any Read transfer may be followed by a subsequent Write command. The Read-to-Write timing diagram illustrates the timing

requirements for a Read followed by a Write. Some systems having long line lengths or severe skews may need additional NOP cycles

inserted between Read and Write commands to prevent data bus contention.

                                                           Read Command

                                                  CK

                                                  CK

                                                  CS

                                                  WE

                                                  REF

                                                  Addr            A

                                                  BA(2:0)         BA

Rev: 1.03 7/2014                                           24/62                                                       © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                       GS4288C09/18/36L

                                                         Read     Burst    Length 2,       Configuration        1

           T0                  T1                 T2                   T3              T4               T5                T6                T7                  T8

                                             RC = 4

CK

CK

CMD   RD                  RD                 RD                   RD              RD               RD                RD                RD                  RD

ADDR  A                   A                  A                    A               A                A                 A                 A                   A

BA    BA0                 BA1                BA2                  BA3             BA0              BA7               BA6               BA5                 BA4

                                             RL = 4

QKx

QKx

QVLD

DQ                                                                                            Q0a  Q0b          Q1a  Q1b          Q2a  Q2b          Q3a    Q3b           Q0a

                                                         Read     Burst    Length 4, Configuration              1

           T0                  T1                    T2                T3                 T4                T5                T6                T7                   T8

                                             RC = 4

CK

CK

CMD   RD                  NOP                RD                   NOP             RD               NOP                    RD           NOP                      RD

ADDR  A                                      A                                         A                                  A                                     A

BA    BA0                                    BA1                                  BA0                                BA1                                        BA3

                                             RL = 4

QKx

QKx

QVLD

DQ                                                                                            Q0a  Q0b          Q0c  Q0d          Q1a     Q1b       Q1c         Q1d           Q0a

Rev: 1.03 7/2014                                                           25/62                                                                ©   2011,  GSI Technology

Specifications cited are  subject to change  without notice. For  latest documentation see http://www.gsitechnology.com.
                                                                                                                                                 GS4288C09/18/36L

                                                         Read-Write   Burst Length                 2,   Configuration 1

                 T0               T1                          T2                   T3                        T4               T5                 T6                      T7

CK

CK

CMD         RD               WR                          WR                   NOP                       NOP              NOP                NOP                     NOP

ADDR        A                A                           A

BA          BA0              BA1                         BA2

DK                                                                                         WL = 5

DK

DM

DQ                                                                                                               Q0a     Q0b                D1a         D1b         D2a           D2b

QVLD

QKx                                                      RL = 4

QKx

                                                         Read-Write   Burst Length                 4,   Configuration 1

                         T0            T1                         T2                   T3                    T4               T5                 T6                 T7

      CK

      CK

      CMD            RD           NOP                       WR                NOP                       NOP              NOP                NOP                NOP

      ADDR           A                                        A

      BA         BA0                                     BA1

      DK                                                                                                         WL = 5

      DK

      DM

      DQ                                                                                                         Q0a     Q0b           Q0c  Q0d                D1a           D1b

      QVLD

      QKx                                                     RL = 4

      QKx

Rev: 1.03 7/2014                                                              26/62                                                                  ©  2011,  GSI  Technology

Specifications cited are     subject to change  without  notice. For  latest  documentation        see  http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Auto Refresh

The Auto Refresh (AREF) command launches a REFRESH cycle on one row in the bank addressed. Refresh row addresses are

generated by an internal refresh counter, so address inputs are Don’t Care, but a bank addresses (BA 2:0) must be provided during

the AREF command. A refresh may be contining in one bank while other commands, including other AREF commands, are

launched in other banks. The delay between the AREF command and a READ, WRITE or AREF command to the same bank must

be at least tRC.

The entire memory must be refreshed every 32 ms (tREF). This means that this 288Mb device requires 64K refresh cycles at an

average periodic interval of 0.49s MAX (actual periodic refresh interval is 32 ms/8K rows/8 banks = 0.488s). To improve

efficiency, eight AREF commands (one for each bank) can be launched at periodic intervals of 3.90s (32 ms/8K rows = 3.90s).

The Auto Refresh Cycle diagram illustrates an example of a refresh sequence.

                        Auto Refresh (AREF) Command

                              CK

                              CK

                              CS

                              WE

                        REF

                        A(20:0)

                        BA(2:0)          BA

                                 Auto Refresh Cycle

CK

CK

CMD               AREF  AREF                                                  NOP                                      AREF

Bank              BA0   BA3                                                                                            BA4

Rev: 1.03 7/2014                  27/62                                                                                © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Address Multiplexing

LLDRAM II defaults to “broadside” addressing at power up, meaning, it registers all address inputs on a single clock transition.

However, for most configurations of the device, considerable efficiency can be gained by operating in Address Multiplexed mode,

cutting the address pin count on the host device in half. In Multiplexed Address mode, the address is loaded in two consecutive

clock transitions. Broadside Addressing only improves Continuous Burst mode data transfer efficiency of Burst Length 2 (BL = 2)

configuration.

In Address Multiplex mode, bank addresses are loaded on the same clock transition as Command and the first half of the address,

Ax. The 576Mb Address Mapping in Multiplexed Address Mode table and Cycle Time and Read/Write Latency Configuration in

Mulitplexed Mode table show the addresses needed for both the first and second clock transitions (Ax and Ay, respectively). The

AREF command does not require an address on the second clock transition, as only the Bank Address are loaded for refresh

commands. Therefore, AREF commands may be issued on consecutive clocks, even when in Address Multiplex mode.

Setting Mode Register Bit 5 (M5) to 1 in the Mode Register activates the Multiplexed Address mode. Once this bit is set

subsequent MRS, READ, and WRITE operate as described in the Multiplexed Address Mode diagram.

Rev: 1.03 7/2014      28/62                                                                                            © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                        GS4288C09/18/36L

                                                      Power-Up Multiplexed                Address  Mode

VEXT

VDD

VDDQ

VREF

VTT

                          200us Min                                                tMRSC           tMRSC                  Refresh  All  Banks(9) 1024 NOP cycles Min

         tCK

         tCKL

         tCKH

CK

CK

         tDK

         tDKH

DK       tDKL

DK

Command       NOP         NOP         MRS             MRS        MRS               NOP    MRS      NOP                    REF           REF     NOP                   AC

ADDR                                  CODE(1,2)       CODE(1,2)  CODE(2,3)                Ax(2,4)  Ay(2)                                                              Valid(5)

Bank                                                                                                                      Bank 0        Bank 7                        Valid(5)

Rev: 1.03 7/2014                                                            29/62                                                            © 2011, GSI Technology

Specifications cited are  subject to  change without  notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

MRS Command In Multiplexed Mode

The Mode Register Set command stores the data for controlling the RAM into the Mode Register. The register allows the user to

modify Read and Write pipeline length, burst length, test mode, and I/O options. The Multiplexed MRS command requires two

cycles to complete The Ax address is sampled on the true crossing of clock with the MRS Command. The Ay address and a

required NOP command are captured on the next next crossing of clock. After issuing a valid MRS command, tMRSC must be met

before any READ, WRITE, MRS, or AREF command can be issued to the LLDRAM II. This statement does not apply to the

consecutive MRS commands needed for internal logic reset during the initialization routine. The MRS command can only be

issued when all banks are idle and no bursts are in progress.

Note: The data written by the prior burst length is not guaranteed to be accurate when the burst length of the device is changed.

                                                  MRS  Command      in  Multiplexed Mode

                                                               MRS

                                 CK

                                 CK

                                 CS

                                 WE

                                 REF

                                 A(20:0)               Ax                               Ay

                                 BA(2:0)

Notes:

1.  Recommended that all address pins held Low during dummy MRS commands.

2.  A10–A18 must be Low.

3.  Set address A5 High. This enbles the part to enter Multiplexed Address mode when in Non-Multiplexed mode operation. Multiplexed

    Address mode can also be entered at some later time by issuing an MRS command with A5 High. Once address Bit A5 is set High, tMRSC

    must be satisfied before the two-cycle multiplexed mode MRS command is issued.

4.  Address A5 must be set High. This and the following step set the desired mode register once the LLDRAM II is in Multiplexed Address

    mode.

5.  Any command or address.

6.  The above sequence must be followed in order to power up the LLDRAM II in the Multiplexed Address mode.

7.  DLL must be reset if tCK or VDD are changed.

8.  CK and CK must separated at all times to prevent bogus commands from being issued.

9.  The sequence of the eight AUTO REFRESH commands (with respect to the 1024 NOP commands) does not matter. As is required for any

    operation, tRC must be met between an AUTO REFRESH command and a subsequent VALID command to the same bank.

Rev: 1.03 7/2014                                       30/62                                                           © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                      GS4288C09/18/36L

                                  Mode Register Definition in Multiplexed Address Mode

                              Ax  A18...A10      A9         A8                     A5     A4      A3                            A0

                              Ay  A18...A10                     A9         A8                         A4               A3

                                  18–10          9          8   7       6       5      4         3    2                1        0     Mode Register (Mx)

                                  Reserved1      ODT        IM  DLL    NA5     AM         BL              Config

                                  On Die                                                                                  M2     M1   M0  Configuration

                              M9  Termination

                                                                                                                          0        0  0   12 (default)

                              0   Off (default)                                                                           0        0  1   12

                              1           On

                                                                                                                          0        1  0   2

                                                                                                                          0        1  1   3

    M8  Drive Impedance                   M7     DLL Reset                                                                1        0  0   42

    0   Internal 503 (default)           0      DLL reset4 (default)

    1   External (ZQ)                                                                                                     1        0  1   5

                                          1      DLL enabled                                                              1        1  0   Reserved

                                                                                                                          1        1  1   Reserved

                  M5              Address MUX

                                                                                              M4      M3                  Burst

                  0               Nonmulitplexed (default)                                                                Length

                  1               Multiplexed                                                 0       0                2 (default)

                                                                                              0       1                      4

                                                                                              1       0                      8

                                                                                              1       1                Reserved

Notes:

1.  A10–A18 must be set to zero.

2.  BL = 8 is not available.

3.  +/–30% over rated temperature range.

4.  DLL RESET turns the DLL off.

5.  Ay8 not used in MRS.

6.  BA0–BA2 are “Don’t Care”.

7.  Addresses A0, A3, A4, A5, A8, and A9 must be set as shown in order      to  activate  the Mode    Register in the Multiplexed         Address mode.

Rev: 1.03 7/2014                                                31/62                                                                 © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                               GS4288C09/18/36L

288Mb Address Mapping         in Multiplexed Address  Mode

Data Width            Burst        Ball                                                    Address

                      Length             A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                      2            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                                   Ay    X            A1     A2      X                 A6     A7                       X    A11       A12       A16    A15

    x36               4            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    X

                                   Ay    X            A1     A2      X                 A6     A7                       X    A11       A12       A16    A15

                      8            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       X      X

                                   Ay    X            A1     A2      X                 A6     A7                       X    A11       A12       A16    A15

                      2            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                                   Ay    X            A1     A2      X                 A6     A7                       A19  A11       A12       A16    A15

    x18               4            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                                   Ay    X            A1     A2      X                 A6     A7                       X    A11       A12       A16    A15

                      8            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    X

                                   Ay    X            A1     A2      X                 A6     A7                       X    A11       A12       A16    A15

                      2            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                                   Ay    A20          A1     A2      X                 A6     A7                       A19  A11       A12       A16    A15

    x9                4            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                                   Ay    X            A1     A2      X                 A6     A7                       A19  A11       A12       A16    A15

                      8            Ax    A0           A3     A4      A5                A8     A9                       A10  A13       A14       A17    A18

                                   Ay    X            A1     A2      X                 A6     A7                       X    A11       A12       A16    A15

Notes:

X = Don’t Care.

Configuration in Mulitplexed Mode

In Multiplexed Address mode, the Read and Write latencies are increased by one clock cycle. However, the LLDRAM II cycle time

remains the same as when in Nonmultiplexed Address mode.

Cycle Time and Read/Write Latency Configuration in Mulitplexed Mode

         Parameter                                           Configuration                                                                      Units

                              12              2                  3                         42, 3                            5

            tRC               4               6                  8                         3                                5                   tCK

            tRL               5               7                  9                         4                                6                   tCK

            tWL               6               8                  10                        5                                7                   tCK

    Valid Frequency Range     266–175    400–175             533–175                       200–175                          333–175             MHz

Notes:

1.  tRC < 20 ns in any configuration is only available with –24 and –18 speed grades.

2.  BL = 8 is not available.

3.  The minimum tRC is typically 3 cycles, except in the case of a Write followed by a Read to the same                bank. In this  instance  the minimum

    tRC is 4 cycles.

Rev: 1.03 7/2014                                      32/62                                                                           © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                 GS4288C09/18/36L

Write Command in Multiplexed Mode

Address Multiplexed Write data transfers are launched with a Write command, as shown below. A valid address must be provided

during the Write command. The Ax address must be loaded on the same true clock crossing used to load the Write command and

the Bank address. The Ay address and a NOP command must be provided at the next clock crossing.

During Write data transfers, each beat of incoming data is registered on crossings of DK and DK until the burst transfer is

complete. Write Latency (WL) is always one cycle longer than the programmed Read Latency (RL).

A Write burst may be followed by a Read command (assuming tRC is met). At least one NOP command is required between Write

and Read commands to avoid data bus contention. The Write-to-Read timing diagrams illustrate the timing requirements for a

Write followed by a Read. Setup and hold times for incoming DQ relative to the DK edges are specified as tDS and tDH. Input data

may be masked high on an associated DM pin. The setup and hold times for the DM signal are tDS and tDH.

                                           Write    Command in            Multiplexed Mode

                                                                   WRITE

                                           CK

                                           CK

                                           CS

                                           WE

                                           REF

                                           A(20:0)             Ax                 Ay

                                           BA(2:0)             BA

                       Write Burst                  Length 4,  Configuration   1  in Multiplexed Mode

      T0          T1               T2               T3                    T4      T5                                   T6        T7        T8

                                   RC = 4

CK

CK

CMD   WR          NOP              WR               NOP                   WR      NOP                                  WR        NOP       WR

ADDR  Ax          Ay               Ax               Ay                    Ax      Ay                                   Ax        Ay        Ax

BA    BA0                          BA1                                    BA0                                          BA3                 BA0

                                                    WL = 6

DK

DK

DM

D                                                                                                                      D0a  D0b  D0c  D0d  D1a  D1b

Rev: 1.03 7/2014                                               33/62                                                                  © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Read Command in Multiplexed Mode

Address Multiplexed Read data transfers are launched with a Read command, as shown below. A valid address must be provided

during the READ command. The Ax address must be loaded on the same True clock crossing used to load the READ command

and the Bank address. The Ay address and a NOP command must be provided at the next clock crossing.

Each beat of a Read data transfer is edge-aligned with the QKx signals. After a programmable Read Latency, data is available at

the outputs. One half clock cycle prior to valid data on the read bus, the data valid signal (QVLD) is driven High. QVLD is also

edge-aligned with the QKx signals. The QK clocks are free-running.

The skew between QK and the crossing point of CK is specified as tCKQK. tQKQ0 is the skew between QK0 and the last valid

data edge generated at the DQ signals associated with QK0 (tQKQ0 is referenced to DQ0–DQ17 for the x36 configuration and

DQ0–DQ8 for the x18 configuration). tQKQ1 is the skew between QK1 and the last valid data edge generated at the DQ signals

associated with QK1 (tQKQ1 is referenced to DQ18–DQ35 for the x36 and DQ9–DQ17 for the x18 configuration). tQKQx is

derived at each QKx clock edge and is not cumulative over time. tQKQ is defined as the skew between either QK differential pair

and any output data edge.

At the end of a burst transfer, assuming no other commands have been initiated, output data (DQ) will go High–Z. The QVLD

signal transitions Low on the beat of a Read burst. Note that if CK/CK violates the VID(DC) specification while a Read burst is

occurring, QVLD remains High until a dummy Read command is issued. Back-to-back Read commands are possible, producing a

continuous flow of output data.

The data valid window specification is referenced to QK transitions and is defined as: tQHP – (tQKQ [MAX] + |tQKQ [MIN]|). See

the Read Data Valid Window section.

Any Read transfer may be followed by a subsequent Write command. The Read-to-Write timing diagram illustrates the timing

requirements for a Read followed by a Write. Some systems having long line lengths or severe skews may need additional NOP

cycles inserted between Read and Write commands to prevent data bus contention.

                                     Read Command in Mulitplexed Mode

                                                  READ

                                     CK

                                     CK

                                     CS

                                     WE

                                     REF

                                     A(20:0)  Ax                                 Ay

                                     BA(2:0)  BA

Rev: 1.03 7/2014                              34/62                                                                    © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                  GS4288C09/18/36L

                           Read Burst Length 4,  Configuration  1  in  Multiplexed                                     Mode

      T0          T1           T2           T3          T4             T5                                              T6         T7        T8

CK                     RC  =4

CK

CMD   RD          NOP          RD           NOP         RD             NOP                                             RD         NOP       RD

ADDR  Ax          Ay           Ax           Ay          Ax             Ay                                              Ax         Ay        Ax

BA    BA0                      BA1                      BA2                                                            BA0                  BA1

                                    RL = 5

QKx

QKx

QVLD

Q                                                                           Q0a                                        Q0b   Q0c  Q0d  Q1a  Q1b  Q1c

Rev: 1.03 7/2014                                 35/62                                                                            © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                   GS4288C09/18/36L

Refresh Commands in Multiplexed Address Mode

The AREF command launches a REFRESH cycle on one row in the bank addressed. Refresh row addresses are generated by an

internal refresh counter. so address inputs are Don’t Care, but Bank addresses (BA 2:0) must be provided during the AREF

command. A refresh may be continuing in one bank while other commands, including other AREF commands, are launched in

other banks. The delay between the AREF command and a READ, WRITE or AREF command to the same bank must be at least

tRC.

The entire memory must be refreshed every 32 ms (tREF). This means that this 576Mb device requires 128K refresh cycles at an

average periodic interval of 0.24s MAX (actual periodic refresh interval is 32 ms/16K rows/8 = 0.244s). To improve efficiency,

eight AREF commands (one for each bank) can be launched at periodic intervals of 1.95s (32 ms/16K rows = 1.95s). The Auto

Refresh Cycle diagram illustrates an example of a refresh sequence.

Unlike READ and WRITE commands in Address Multiplex mode, all the information needed to execute an AREF command (the

AREF command and the Band Address (BA 2:0)) is loaded in a single clock crossing, another AREF command (to a different

bank) may be loaded on the next clock crossing.

                                             Consecutive Refresh Operations with Multiplexed Mode

                T0              T1           T2    T3    T4           T5    T6    T7                                   T8    T9        T10      T11

        CK

        CK

      CMD   AC              NOP              AREF  AREF  AREF         AREF  AREF  AREF                                 AREF  AREF  AC       NOP

      ADDR  Ax              Ay                                                                                                     Ax       Ay

        BA  BAn                              BA0   BA1   BA2          BA3   BA4   BA5                                  BA6   BA7   BAn

Notes:

1.    Any command.

2.    Bank n is chosen  so  that    tRC  is  met.

Rev: 1.03 7/2014                                               36/62                                                               © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                   GS4288C09/18/36L

Absolute Maximum Ratings

Absolute Maximum Voltage

(All voltages reference to VSS)

                  Parameter                                  Min                                                       Max               Unit

                  I/O Voltage                                –0.3                                                      VDDQ + 0.3        V

                  Voltage on VEXT supply                     –0.3                                                      +2.8              V

        Voltage on VDD supply relative to VSS                –0.3                                                      +2.1              V

        Voltage on VDDQ supply relative to VSS               –0.3                                                      +2.1              V

Note:

Permanent damage to the device may occur if the Absolute Maximum Ratings are exceeded. Operation should be restricted to Recommended

Operating Conditions. Exposure to conditions exceeding the Absolute Maximum Ratings, for an extended period of time, may affect reliability of

this component.

Absolute Maximum Temperature

                  Parameter                     Temperature  Symbol                  Min.                                    Max.  Unit     Notes

                                                Range

                  Storage Temperature           —            TSTG                    –55                                     +150  C°             1

        Reliability junction temperature        Commercial   TJ                      —                                       +110  C°             2

                                                Industrial                           —                                       +110  C°             2

Notes:

1.     Max storage case temperature; TSTG is measured in the center of the package.

2.     Temperatures greater than 110 C° may cause permanent damage to the device. This is a stress rating only and functional operation of the

       device at or above this is not implied. Exposure to the absolute maximum ratings condtions for extended periods may affect reliability of

       the part.

Rev: 1.03 7/2014                                37/62                                                                              © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                       GS4288C09/18/36L

Recommended Operating Temperature and Thermal Impedance

Like any other semiconcuctor device, the LLDRAM II must be operated within the temperature specifications shown in the

Temperature Limits table for the device to meet datasheet specifications. The thermal impedance characteristics of the device are

are listed below. In applications where the ambient temperature or PCB temperature are too high, use of forced air and/or heat

sinks may be required in order to satisfy the case temperature specifications.

Temperature Limits

                  Parameter                            Temperature         Symbol              Min.                              Max.         Unit  Notes

                                                       Range

        Operating junction temperature                 Commercial          TJ                  0                                 +100         C°    1

                                                       Industrial                              –40                               +100         C°    1

          Operating case temperature                   Commercial          TC                  0                                 +95          C°    2, 3

                                                       Industrial                              –40                               +95          C°    2, 3, 4

Notes:

1.  Junction temperature depends upon package type, cycle time, loading, ambient temperature,        and               airflow.

2.  Maximum operating case temperature, TC, is measured in the center of the package.

3.  Device functionality is not guaranteed if the device exceeds maximum TC during operation.

4.  Junction and case temperature specifications must be satisfied.

Thermal Impedance

    Package       Test PCB              JA (C°/W)     JA (C°/W)                      JA (C°/W)                               JB (C°/W)         JC (C°/W)

                  Substrate           Airflow = 0 m/s  Airflow = 1 m/s                 Airflow = 2 m/s

    BGA          2-layer               29.0                         21.9                      19.9                              13.6               4.0

                  4-layer               18.5                         13.5                      12.6                              12.4               4.2

Notes:

1.  Thermal Impedance data is based on a number of of samples from mulitple lots and should be viewed as a typical number.

2.  Please refer to JEDEC standard JESD51-6.

3.  The characteristics of the test fixture PCB influence reported thermal characteristics of the device. The minimal metalization of a 2-layer

    board tends to minimize the utility of the junction-to-board heat path. The 4-layer test fixture PCB is intended to highlight the effect of

    connection to power planes typically found in the PCBs used in most applications. Be advised that a good thermal path to the PCB can

    result in cooling or heating of the RAM depending on PCB temperature.

Rev: 1.03 7/2014                                       38/62                                                                           © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                   GS4288C09/18/36L

Recommended DC Operating Conditions and Electrical Characteristics

        Description                Conditions              Symbol                  Min.                                Max.          Unit    Notes

        Supply Voltage             —                       VEXT                    2.38                                2.63              V      —

        Supply Voltage             —                       VDD                     1.7                                 1.9               V      2

    Isolated Output Buffer Supply  —                       VDDQ                    1.4                                 VDD               V      2, 3

        Reference Voltage          —                       VREF                    0.49 * VDDQ                         0.51 * VDDQ       V   4, 5, 6

        Termination Voltage        —                       VTT                     0.95 * VREF                         1.05 * VREF       V      7, 8

     Input High (logic 1) voltage  —                       VIH(DC)                 VREF + 0.1                          VDDQ + 0.3        V      2

     Input Low (logic 0) voltage   —                       VIL(DC)                 VSS – 0.3                           VREF – 0.1        V      2

        Ouput High Current         VOUT = VDDQ/2           IOH            (VDDQ/2)/(1.15 * RQ/5)  (VDDQ/2)/(0.85 * RQ/5)                 A   9, 10, 11

        Ouput Low Current          VOUT = VDDQ/2           IOL            (VDDQ/2)/(1.15 * RQ/5)  (VDDQ/2)/(0.85 * RQ/5)                 A   9, 10, 11

    Clock Input Leakage Current    0 V VIN VDD          ILC                     –5                                  5                 A     —

     Input Leakage Current         0 V VIN VDD          ILI                     –5                                  5                 A     —

     Output Leakage Current        0 V VIN VDDQ         ILO                     –5                                  5                 A     —

     Reference Voltage Current     —                       IREF                    –5                                  5                 A     —

Notes:

1.   All voltages referenced to VSS (GND). This note applies to the entire table.

2.   Overshoot VIH(AC)  VDD+ 0.7 V for t  tCK/2. Undershoot: VIL(AC)  –0.5 V for t  tCK/2. During normal operation VDDQ must not exceed

     VDD. Control input signals may not have pulse widthts less than tCK/2 or operate at frequencies exceeding tCK (MAX).

3.   VDDQ can be set to a nominal 1.5 V ± 0.1 V or 1.8 V ± 0.1 V supply.

4.   Typically the value of VREF is expected to be 0.5 * VDDQ of the transmitting device. VREF is expected to track variations in VDDQ.

5.   Peak-to-Peak AC noise on VREF must not exceed ±2% of VREF(DC).

6.   VREF is expected to equal VDDQ/2 of the transmitting device and to track variations in the DC level of the same. Peak-to-peak noise 

     (non-common mode) on VREF may not exceed ±2% of the DC value. Thus, from VDDQ/2, VREF is allowed ±2% VDDQ/2 for DC error and an

     addtional ±2% VDDQ/2 for AC noise. This measurement is to be taken at the nearest VREF bypass capacitor.

7.   VTT is expected to be set equal to VREF and must track variations in the DC level of VREF.

8.   On-die termination may be selected using Mode Register Bit 9 (M9). A resistance RTT from each data input signal to the nearest VTT can be

     enabled. RTT = 125–185at 95° C TC.

9.   IOH and IOL are defined as absolute values and are measured at VDDQ/2. IOH flows from the device, IOL flows into the device.

10.  If Mode Register Bit 8 (M8) is 0, use RQ = 250in the equation in lieu of presence of an external impedance matched resistor.

11.  For VOL and VOH, refer to the LLDRAM II IBIS models.

Rev: 1.03 7/2014                                           39/62                                                                    © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                             GS4288C09/18/36L

DC Differential Input Clock Logic Levels

                  Parameter                      Symbol               Min.                                             Max.                    Unit  Notes

        Clock input voltage level: CK and CK     VIN(DC)              –0.3                           VDDQ + 0.3                                V     1–4

    Clock input differential voltage: CK and CK  VID(DC)              0.2                            VDDQ + 0.6                                V     1–5

Notes:

1.  DKx and DKx have the same requirements as CK and CK.

2.  All voltages referenced to VSS (GND).

3.  The CK and CK input reference level (for timing referenced to CK/CK) is the point at which CK and CK cross. The input reference level for

    signals other than CK/CK is VREF.

4.  The CK and CK input slew rate must be  2 V/ns ( 4 V/ns if measured differentially).

5.  VID is the magnitude of the difference between the input level on CK and the input level on CK.

Recommended AC Operating Conditions and Electrical Characteristics

Input AC Logic Levels

                  Parameter                               Symbol            Min.                                       Max.  Unit                    Notes

                  Input High (logic 1) Voltage                   VIH  VREF + 0.2                                       —     V                       1, 2, 3

                  Input Low (logic 0) Voltage                    VIL        —                        VREF – 0.2              V                       1, 2, 3

Notes:

1.  All voltages referenced to VSS (GND).

2.  The AC and the DC input level specifications are defined in the HSTL standard (that is, the receiver will effectively switch as a result of the

    signal crossing the AC input level, and will remain in that state as long as the signal does not ring back above (see drawing below) the DC

    input Low (High) level).

3.  The minimum slew rate for the input signals used to test the device is 2 V/ns in the range between VIL(AC) and VIH(AC).

                                       Nominal tAS/ tCS/ tDS and tAH/ tCH/ tDH Slew Rate

                              VDDQ

                  VIH(AC)MIN

                  VIH(DC)MIN                                                                                                 VSWING(AC) (MIN)

                              VREF

                  VIL(DC)MAX

                  VIL(AC)MAX

                              VSS

Rev: 1.03 7/2014                                          40/62                                                                                © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                      GS4288C09/18/36L

AC Differential Input Clock Levels

                  Parameter                        Symbol                   Min.                                       Max.           Unit            Notes

    Clock input differential voltage: CK and CK    VID(AC)                  0.4                      VDDQ + 0.6                       V               1–5

    Clock input crossing point voltage: CK and CK  VIX(AC)                  VDDQ/2 – 0.15            VDDQ/2 + 0.15                    V               1–4, 6

Notes:

1.  DKx and DKx have the same requirements as CK and CK.

2.  All voltages referenced to VSS (GND).

3.  The CK and CK input reference level (for timing referenced to CK/CK) is the point at which CK and CK cross. The input reference level for

    signals other than CK/CK is VREF.

4.  The CK and CK input slew rate must be  2 V/ns ( 4 V/ns if measured differentially).

5.  VID is the magnitude of the difference between the input level on CK and the input level on CK.

6.  The value of VIX is expected to equal VDDQ/2 of the transmitting device and must track variations in the DC level of the same.

                                                 Differential Clock Input Requirements

        VIN(DC) MAX                                                                                  Maximum Clock Level

                     CK

        VDDQ/2 + 0.15                                                                                                  VIX(AC)MAX                     VID(AC)3

                  VDDQ/2                                                                                                           1        VID(DC)2

        VDDQ/2 – 0.15                                                                                                  VIX(AC)MIN

                     CK

        VIN(DC) MIN                                                                                  Minimum Clock Level

Notes:

1.  CK and CK must cross within this region.

2.  CK and CK must meet at least VID(DC)MIN when static and centered around VDDQ/2.

3.  Minimum peak-to-peak swing.

4.  It is a violation to tristate CK and CK after the part is initialized.

Rev: 1.03 7/2014                                          41/62                                                                       © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Input Slew Rate Derating

The Address and Command Setup and Hold Derating Values shown in the following table should be added to the default tAS/tCS/

tDS and tAH/tCH/tDH specifications when the slew rate of any of these input signals is less than the 2 V/ns.

To determine the setup and hold time needed for a given slew rate, add the tAS/tCS default specification to the “tAS/tCS VREF to

CK/CK Crossing” and the tAH/tCH default specification to the "tAH/tCH CK/CK Crossing to VREF" derated values in the Address

and Command Setup and Hold Derating Values table. The derated data setup and hold values can be determined the same way

using the “tDS VREF to CK/CK Crossing” and “tDH to CK/CK Crossing to VREF” values in the Data Setup and Hold Derating

Values table. The derating values apply to all speed grades.

The setup times in the table relate to a rising signal. The time from the rising signal crossing VIH(AC)MIN to the CK/CK cross point

is static and must be maintained across all slew rates. The derated setup timing describes the point at which the rising signal crosses

VREF(DC) to the CK/CK cross point. This derated value is calculated by determining the time needed to maintain the given slew

rate and the delta between VIH(AC)MIN and the CK/CK cross point. All these same values are also valid for falling signals (with

respect to VIL(AC)MAX and the CK/ CK cross point).

The hold times in the table relate to falling signals. The time from the CK/CK cross point to when the signal crosses VIH(DC) MIN is

static and must be maintained across all slew rates. The derated hold timing describes the delta between the CK/CK cross point to

when the falling signal crosses VREF(DC). This derated value is calculated by determining the time needed to maintain the given

slew rate and the delta between the CK/CK cross point and VIH(DC). The hold values are also valid for rising signals (with respect

to VIL(DC)MAX and the CK and CK cross point).

Note: The above descriptions also pertain to data setup and hold derating when CK/CK are replaced with DK/DK.

Rev: 1.03 7/2014                                    42/62                                                              © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Address and Command Setup and Hold Derating Values

Command/Address   tAS/tCS VREF to  tAS/tCS VIH(AC)MIN  tAH/tCH                                                         tAH/tCH             Units

Slew Rate (V/ns)  CK/CK crossing   CK/CK crossing      CK/CK crossing to VREF                                          CK/CK crossing  to

                                                                                                                       VIH(DC)MIN

                                   CK/CK Differential Slew Rate: 2.0 V/ns

2.0               0                –100                                    0                                           –50                 ps

1.9               5                –100                                    3                                           –50                 ps

1.8               11               –100                                    6                                           –50                 ps

1.7               18               –100                                    9                                           –50                 ps

1.6               25               –100                                    13                                          –50                 ps

1.5               33               –100                                    17                                          –50                 ps

1.4               43               –100                                    22                                          –50                 ps

1.3               54               –100                                    27                                          –50                 ps

1.2               67               –100                                    34                                          –50                 ps

1.1               82               –100                                    41                                          –50                 ps

1.0               100              –100                                    50                                          –50                 ps

                                   CK/CK Differential Slew Rate: 1.5 V/ns

2.0               30               –70                                     30                                          –20                 ps

1.9               35               –70                                     33                                          –20                 ps

1.8               41               –70                                     36                                          –20                 ps

1.7               48               –70                                     39                                          –20                 ps

1.6               55               –70                                     43                                          –20                 ps

1.5               63               –70                                     47                                          –20                 ps

1.4               73               –70                                     52                                          –20                 ps

1.3               84               –70                                     57                                          –20                 ps

1.2               97               –70                                     64                                          –20                 ps

1.1               112              –70                                     71                                          –20                 ps

1.0               130              –70                                     80                                          –20                 ps

                                   CK/CK Differential Slew Rate: 1.0 V/ns

2.0               60               –40                                     60                                          10                  ps

1.9               65               –40                                     63                                          10                  ps

1.8               71               –40                                     66                                          10                  ps

1.7               78               –40                                     69                                          10                  ps

1.6               85               –40                                     73                                          10                  ps

1.5               93               –40                                     77                                          10                  ps

1.4               103              –40                                     82                                          10                  ps

1.3               114              –40                                     87                                          10                  ps

1.2               127              –40                                     94                                          10                  ps

1.1               142              –40                                     101                                         10                  ps

1.0               160              –40                                     110                                         10                  ps

Rev: 1.03 7/2014                   43/62                                                                               © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                             GS4288C09/18/36L

Data Setup and Hold    Derating Values

                       tDS VREF to CK/CK  tDS VIH(AC)MIN CK/CK                   tDS                                         tDS                 Units

Data Slew Rate (V/ns)  crossing           crossing                   CK/CK crossing        to                          VREF  CK/CK crossing  to

                                                                                                                             VIH(DC)MIN

                                          DK/DK Differential Slew    Rate: 2.0 V/ns

2.0                    0                         –100                                  0                                     –50                 ps

1.9                    5                         –100                                  3                                     –50                 ps

1.8                    11                        –100                                  6                                     –50                 ps

1.7                    18                        –100                                  9                                     –50                 ps

1.6                    25                        –100                                  13                                    –50                 ps

1.5                    33                        –100                                  17                                    –50                 ps

1.4                    43                        –100                                  22                                    –50                 ps

1.3                    54                        –100                                  27                                    –50                 ps

1.2                    67                        –100                                  34                                    –50                 ps

1.1                    82                        –100                                  41                                    –50                 ps

1.0                    100                       –100                                  50                                    –50                 ps

                                          DK/DK  Differential  Slew  Rate:  1.5  V/ns

2.0                    30                        –70                                   30                                    –20                 ps

1.9                    35                        –70                                   33                                    –20                 ps

1.8                    41                        –70                                   36                                    –20                 ps

1.7                    48                        –70                                   39                                    –20                 ps

1.6                    55                        –70                                   43                                    –20                 ps

1.5                    63                        –70                                   47                                    –20                 ps

1.4                    73                        –70                                   52                                    –20                 ps

1.3                    84                        –70                                   57                                    –20                 ps

1.2                    97                        –70                                   64                                    –20                 ps

1.1                    112                       –70                                   71                                    –20                 ps

1.0                    130                       –70                                   80                                    –20                 ps

                                          DK/DK  Differential  Slew  Rate:  1.0  V/ns

2.0                    60                        –40                                   60                                    10                  ps

1.9                    65                        –40                                   63                                    10                  ps

1.8                    71                        –40                                   66                                    10                  ps

1.7                    78                        –40                                   69                                    10                  ps

1.6                    85                        –40                                   73                                    10                  ps

1.5                    93                        –40                                   77                                    10                  ps

1.4                    103                       –40                                   82                                    10                  ps

1.3                    114                       –40                                   87                                    10                  ps

1.2                    127                       –40                                   94                                    10                  ps

1.1                    142                       –40                             101                                         10                  ps

1.0                    160                       –40                             110                                         10                  ps

Rev: 1.03 7/2014                                 44/62                                                                       © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                  GS4288C09/18/36L

Capacitance

                  Description                  Symbol                       Conditions                                      Min.            Max.       Unit

        Address/control input capacitance      CI                                                                           1.0             2.0        pF

Input/Output capacitance (DQ, DM, and QK, QK)  CO                        TA = 25° C; f = 100 MHz                            3.0             4.5        pF

    Clock capacitance (CK/CK and DK/DK)        CCK                          VDD = VDDQ = 1.8 V                              1.5             2.5        pF

                  JTAG pins                    CJTAG                                                                        1.5             4.5        pF

Notes:

1.  Capacitance is not tested on the ZQ pin.

2.  JTAG Pins are tested at 50 MHz.

IDD Operating Conditions

        Description                            Condition                    Symbol                                     -18        -24  -25        -33  Units

                                                                            ISB1 (VDD) x9/x18                          30         30   30         30

        Standby Current              tCK = idle, All banks idle; No inputs  ISB1 (VDD) x36                             30         30   30         30   mA

                                               toggling.

                                                                            ISB1 (VEXT)                                5          5    5          5

                               CS = 1, No commands; Bank address            ISB2 (VDD) x9/x18                          295        270  270        250

    Active Standby Current     incremented and half address/data change     ISB2 (VDD) x36                             295        270  270        250  mA

                                     once every four clock cycles.          ISB2 (VEXT)                                5          5    5          5

                               BL = 2, Sequential bank access; Bank         IDD1 (VDD) x9/x18                          410        385  365        345

                               transitions once every tRC; Half address     IDD1 (VDD) x36                             420        395  375        355

    Operational Current        transitions once every tRC; Read followed                                                                               mA

                               by Write sequence; Continuous data during    IDD1 (VEXT)                                15         15   15         10

                                              Write Commands.

                               BL = 4, Sequential bank access; Bank         IDD2 (VDD) x9/x18                          420        395  375        355

                               transitions once every tRC; Half address     IDD2 (VDD) x36                             455        430  400        380

    Operational Current        transitions once every tRC; Read followed                                                                               mA

                               by Write sequence; Continuous data during    IDD2 (VEXT)                                25         25   25         20

                                              Write Commands.

                               BL = 8, Sequential bank access; Bank         IDD3 (VDD) x9/x18                          475        450  410        390

                               transitions once every tRC; Half address     IDD3 (VDD) x36                             545        520  465        445

    Operational Current        transitions once every tRC. Read followed                                                                               mA

                               by Write sequence; Continuous data during    IDD3 (VEXT)                                40         40   40         30

                                              Write Commands.

                               Eight bank cyclic refresh; Continuous        IREF1 (VDD) x9/x18                         550        475  470        415

    Burst Refresh Current      address/data; Command bus remains in         IREF1 (VDD) x36                            550        475  470        415  mA

                                           refresh for all eight banks.     IREF1 (VEXT)                               60         60   60         45

Rev: 1.03 7/2014                                          45/62                                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                               GS4288C09/18/36L

IDD Operating Conditions (Continued)

        Description                                  Condition                             Symbol                      -18     -24        -25            -33             Units

                                    Single bank refresh; Sequential bank                   IREF2 (VDD)x9/x18           350     325        320            300

    Distributed Refresh Current     access; Half address transitions once every            IREF2 (VDD)x36              350     325        320            300             mA

                                                   tRC; Continuous data.                   IREF2 (VEXT)                15      15         15             10

                                    BL= 2; Cyclic bank access; Half of address             IDD2W (VDD) x9/x18          795     680        680            585

Operating Burst Write Current       bits change every clock cycle; Continuous              IDD2W (VDD) x36             835     715        715            620             mA

        Example                     data; Measurement is taken during

                                                     continuous Write.                     IDD2W (VEXT)                60      60         60             45

                                    BL= 4; Cyclic bank access; Half of address             IDD4W (VDD )x9/x18          630     540        540            470

Operating Burst Write Current       bits change every two clock cycles;                    IDD4W (VDD) x36             735     630        630            545             mA

        Example                     Continuous data; Measurement is taken

                                                   during continuous Write.                IDD4W (VEXT)                55      55         55             40

                                    BL= 8; Cyclic bank access; Half of address             IDD8W (VDD) x9/x18          595     510        510            445

Operating Burst Write Current       bits change every four clock cycles;                   IDD8W (VDD) x36             695     595        595            515             mA

        Example                     Continuous data; Measurement is taken

                                                   during continuous Write.                IDD8W (VEXT)                55      55         55             40

                                    BL= 2; Cyclic bank access; Half of address             IDD2R (VDD)x9/x18           720     620        620            535

    Operating Burst Read            bits change every clock cycle; Continuous              IDD2R (VDD)x36              735     630        630            545             mA

        Current Example             data; Measurement is taken during

                                                     continuous Read.                      IDD2R (VEXT)                60      60         60             45

                                    BL= 4; Cyclic bank access; Half of address             IDD4R (VDD) x9/x18          570     490        490            425

    Operating Burst Read            bits change every two clock cycles;                    IDD4R (VDD) x36             675     570        570            490             mA

        Current Example             Continuous data; Measurement is taken

                                                   during continuous Read.                 IDD4R (VEXT)                55      55         55             40

                                    BL= 8; Cyclic bank access; Half of address             IDD8R (VDD) x9/x18          555     470        470            410

    Operating Burst Read            bits change every four clock cycles;                   IDD8R (VDD) x36             650     550        550            475             mA

        Current Example             Continuous data; Measurement is taken

                                                   during continuous Read.                 IDD8R (VEXT)                55      55         55             40

Notes:

1.  IDD specifications are tested after the device is properly initialized and is operating at worst-case rated temperature and voltage specifications.

2.  Definitions of IDD Conditions:

        3a. Low is defined as VIN  VIL(AC) MAX.

        3b. High is defined as VIN  VIH(AC) MIN.

        3c. Stable is defined as inputs remaining at a High or Low level.

        3d. Floating is defined as inputs at VREF = VDDQ/2.

        3e. Continuous data is defined as half the DQ signals changng between High and Low every half clock cycle (twice per clock).

        3f. Continuous address is defined as half the address signals changing between High and Low every clock cycles (once per clock).

        3g. Sequential bank access is defined as the bank address incrementing by one every tRC.

        3h. Cyclic bank access is defined as the bank address incrementing by one for each command access. For BL = 2 this is every clock, for BL = 4 this

        is every other clock, and for BL = 8 this is every fourth clock.

3.  CS is High unless a Read, Write, AREF, or MRS command is registered. CS never transitions more than once per clock cycle.

4.  IDD parameters are specified with ODT disabled.

5.  Tests for AC timing, IDD, and electrical AC and DC characteristics may be conducted at nominal reference/supply voltage levels, but the related

    specifications and device operations are tested for the full voltage range specified.

6.  IDD tests may use a VIL-to-VIH swing of up to 1.5 V in the test environment, but input timing is still referenced to VREF (or to the crossing point for CK/CK), and

    parameter specifications are tested for the specified AC input levels under normal use conditions. The minimum slew rate for the input signals used to test

    the device is 2 V/ns in the range between VIL(AC) andVIH(AC).

Rev: 1.03 7/2014                                                   46/62                                                              © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                GS4288C09/18/36L

AC Electrical Characteristics

       Parameter              Symbol               –18                          –24                  –25                          –33          Units  Notes

                                            Min              Max         Min            Max   Min           Max            Min           Max

Clock

Input Clock Cycle Time        tCK           1.875            5.7         2.5            5.7   2.5           5.7            3.3           5.7   ns     —

Input data clock cycle time   tDK                  tCK                          tCK                  tCK                          tCK          ns     —

Clock jitter: period          tJITPER       –100             100         –150           150   –150          150            –200          200   ps     5, 6

Clock jitter: cycle-to-cycle  tJITCC        —                200         —              300   —             300            —             400   ps     —

Clock High Time               tCKH          0.45             0.55        0.45           0.55  0.45          0.55           0.45          0.55  tCK    —

                              tDKH

Clock Low Time                tCKL          0.45             0.55        0.45           0.55  0.45          0.55           0.45          0.55  tCK    —

                              tDKL

Clock to input data clock     tCKDK         –0.3             0.3         –0.45          0.5   –0.45         0.5            –0.45         1.2   ns     —

Mode register set cycle time  tMRSC         6                —           6              —     6             —              6             —     tCK    —
to any command

Setup Times

Address/command and input     tAS/tCS       0.3              —           0.4            —     0.4           —              0.5           —     ns     —
setup time

Data–in and data mask to      tDS           0.17             —           0.25           —     0.25          —              0.3           —     ns     —
DK set up time

Hold Times

Address/command and input     tAH/tCS       0.3              —           0.4            —     0.4           —              0.5           —     ns     —
hold time

Data-in and data mask to      tDH           0.17             —           0.25           —     0.25          —              0.3           —     ns     —
DK setup time

Data and Data Strobe

Output data clock High time   tQKH          0.9              1.1         0.9            1.1   0.9           1.1            0.9           1.1   tCKH   —

Output data clock Low time    tQKL          0.9              1.1         0.9            1.1   0.9           1.1            0.9           1.1   tCKL   —

Half–clock period             tQHP          MIN              —           MIN            —     MIN           —              MIN           —     —      —

                                            (tQKH, tQKL)                 (tQKH, tQKL)         (tQKH, tQKL)                 (tQKH, tQKL)

QK edge to clock edge skew    tCKQK         –0.2             0.2         –0.25          0.25  –0.25         0.25           –0.3          0.3   ns     —

QK edge to output data        tQKQ0,        –0.12            0.12        –0.2           0.2   –0.2          0.2            –0.25         0.25  ns     7

edge                          tQKQ1

QK edge to any output data    tQKQ          –0.22            0.22        –0.3           0.3   –0.3          0.3            –0.35         0.35  ns     8
edge

QK edge to QVLD               tQKVLD        –0.22            0.22        –0.3           0.3   –0.3          0.3            –0.35         0.35  ns     —

Data Valid Window             tDVW          tDVW (MIN)       —           tDVW (MIN)     —     tDVW (MIN)    —              tDVW (MIN)    —     —      9

Rev: 1.03 7/2014                                                         47/62                                                           © 2011, GSI Technology

Specifications cited are subject to change  without notice.  For latest  documentation  see http://www.gsitechnology.com.
                                                                                                                                GS4288C09/18/36L

AC Electrical Characteristics (Continued)

          Parameter              Symbol       –18                        –24                        –25                           –33        Units   Notes

                                         Min       Max            Min         Max            Min                       Max   Min       Max

Refresh

Average Periodic Refresh         tREFI   —         0.49           —           0.49           —                         0.49  —         0.49  s               10
Interval

Notes:

1.   All timing parameters are measured relative to the crossing  point of    CK/CK,  DK/DK  and    to the   crossing        point with VREF of the command,

     address, and data signals.

2.   Outputs measured with equivalent load:

                     VTT

                     50 

          DQ         Test Point

                     10 pF       VOUT

3.   Tests for AC timing IDD, and electrical AC and DC characteristics may be conducted at nominal reference/supply voltage levels, but the

     related specifications and device operations are tested for the full voltage range specified.

4.   AC timing may use a VIL– to–VIH swing of up to 1.5 V in the test environment, but input timing is still referenced to VREF (or to the crossing

     point for CK/CK), and parameter specifications are tested for the specified AC input levels under normal use conditions. The minimum slew

     rate for the input signals used to test the device is 2 V/ns in the rance between VIL(AC) and VIH(AC).

5.   Clock phase jitter is the variance from clock rising edge to the next expected clock rising edge.

6.   Frequency drift is not allowed.

7.   tQKQ0 is referenced to DQ0–DQ17 for the x36 xconfiguration and DQ0–DQ8 for the x18 configuration. tQKQ1 is referenced to

     DQ18–DQ35 for the x36 configuration and the DQ9–DQ17 for the x18 configuration.

8.   tQKQ takes in to account the skew between any QKx and any Q.

9.   tDVW (MIN) tQHP – (tQKQx [MAX] + |tQKQx [MIN]|)

10.  To improve efficiency, eight AREF commands (one for each bank) can be posted to the LLDRAM II on consecutive cycles at periodic

     intervals of 3.90 s

Rev: 1.03 7/2014                                                  48/62                                                           © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                                              GS4288C09/18/36L

                                                       Read Data Valid Window for x18 Device

        QK0                                                        tQHP1                                                            tQHP1

        QK0

    DQ_Lower_0                                         B"1"                                                             B"0"

    DQ_Lower_1                                               B"0"                                                             B"1"

    DQ_Lower_2                                                     B"1"                                                             B"0"

    DQ_Lower_3                                                             B"0"                                                             B"1"

    DQ_Lower_4                                                                   B"1"                                                             B"0"

    DQ_Lower_5                                                             B"0"                                                             B"1"

    DQ_Lower_6                                                     B"1"                                                             B"0"

    DQ_Lower_7                                               B"0"                                                             B"1"

    DQ_Lower_8                                         B"1"                                                             B"0"

                               tQKQ0(Min)                                                       tQKQ0(Min)                                                    tQKQ0(Min)

                                           tQKQ0(Max)                                                       tQKQ0(Max)

                                                                   tDVW3                                                            tDVW3

    DQ_Lower     X"ZZZ"                                            X"155"                                                           X"0AA"                                       X"ZZZ"

        QK1                                                        tQHP1                                                            tQHP1

        QK1

    DQ_Upper_9                                         B"0"                                                             B"1"

    DQ_Upper_10                                              B"1"                                                             B"0"

    DQ_Upper_11                                                    B"0"                                                             B"1"

    DQ_Upper_12                                                            B"1"                                                             B"0"

    DQ_Upper_13                                                                  B"0"                                                             B"1"

    DQ_Upper_14                                                            B"1"                                                             B"0"

    DQ_Upper_15                                                    B"0"                                                             B"1"

    DQ_Upper_16                                              B"1"                                                             B"0"

    DQ_Upper_17                                        B"0"                                                             B"1"

                               tQKQ1(Min)                                                       tQKQ1(Min)                                                    tQKQ1(Min)

                                           tQKQ1(Max)                                                       tQKQ0(Max)

                                                                   tDVW3                                                            tDVW3

    DQ_Upper     X"ZZZ"                                            X"0AA"                                                           X"155"                                       X"ZZZ"

Notes:

1.  tQHP is defined as the lesser of tQKH or tQKL.

2.  tQKQ0 is referenced to DQ0–DQ8.

3.  Minimum data valid window (tDVW) can be expressed as                                   tQHP – (tQKQx [MAX] +        |tQKQx [MIN]|).

4.  tQKQ1 is referenced to DQ9–DQ17.

5.  tQKQ takes into account the skew between any QKx and                               any DQ.

                                                                                 Read Burst Timing

                         tCKH              tCKL                                        tCK

    CK

    CK

                                                                           tCKQK                                                                        tQKL  tQKH

    QKx

    QKx

                                                       tQKVLDmax                                                                                  tQKVLDmin

    QVLD

                                                                                                tQKQmin

                                                                                       tQKQmax                                                          tDVW

    DQ                                                                                 Q0       Q1                      Q2                              Q3

Rev: 1.03 7/2014                                                                       49/62                                                                  ©           2011,  GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

IEEE 1149.1 Serial Boundary Scan (JTAG)

LLDRAM II includes an IEEE 1149.1 (JTAG) serial boundary scan Test Access Port (TAP). JTAG ports are generally used to

verify the connectivity of the device once it has been mounted on a Printed Circuit Board (PCB). The port operates in accordance

with IEEE Standard 1149.1-2001 (JTAG). Because the ZQ pin is actually an analog output, to ensure proper boundary-scan testing

of the ZQ pin, Mode Register Bit 8 (M8) needs to be set to 0 until the JTAG testing of the pin is complete. Note that upon power

up, the default state of Mode Register Bit 8 (M8) is Low.

Whenever the JTAG port is used prior to the initialization of the LLDRAM II device, such as when initial conectivity testing is

conducted, it is critical that the CK and CK pins meet VID(DC) or that CS be held High from power-up until testing begins. Failure

to do so can result in inadvertent MRS commands being loaded and causing unexpected test results. Alternately a partial

initialization can be conducted that consists of simply loading a single MRS command with desired MRS Register settings. JTAG

testing may then begin as soon as tMRSC is satisfied. JTAG testing can be conducted after full initilization as well.

The input signals of the test access port (TDI, TMS, and TCK) are referenced to the VDD as a supply, while the output driver of the

TAP (TDO) is powered by VDDQ.

The JTAG test access port incorporates a standardTAP controller from which the Instruction Register, Boundary Scan Register,

Bypass Register, and ID Code Register can be selected. Each of these functions of the TAP controller are described below.

Disabling the JTAG Feature

Use of the JTAG port is never required for RAM operation. To disable the TAP controller, TCK must be tied Low (VSS) to prevent

clocking of the device. TDI and TMS are internally pulled up and may be unconnected or they can be connected to VDD directly or

through a pull-up resistor. TDO should be left unconnected. Upon power-up, the device will come up in a reset state, which will not

interfere with the operation of the device.

Test Access Port (TAP)

Test Clock (TCK)

The test clock is used only with the TAP controller. All inputs are captured on the rising edge of TCK. All outputs are driven from

the falling edge of TCK.

Test Mode Select (TMS)

The TMS input is used to give commands to the TAP controller and is sampled on the rising edge of TCK.

All of the states in the TAP Controller State Diagram are entered through the serial input of the TMS pin. A “0” in the diagram

represents a Low on the TMS pin during the rising edge of TCK while a “1” represents a High on TMS.

Test Data-In (TDI)

The TDI ball is used to serially input test instructions and data into the registers and can be connected to the input of any of the

registers. The register between TDI and TDO is chosen by the instruction that is loaded into the TAP instruction register. For

information on loading the instruction register, see the TAP Controller State Diagram. TDI is connected to the Most Significant Bit

(MSB) of any register (see the TAP Controller Block Diagram).

Test Data-Out (TDO)

The TDO output ball is used to serially clock test instructions and data out from the registers. The TDO output driver is only active

during the Shift-IR and Shift-DR TAP controller states. In all other states, the TDO pin is in a High-Z state. The output changes on

the falling edge of TCK. TDO is connected to the Least Significant Bit (LSB) of any register (see the TAP Controller Block

Diagram).

TAP Controller

The TAP controller is a finite state machine that uses the state of the TMS pin at the rising edge of TCK to navigate through its

various modes of operation. See the TAP Controller State Diagram. Each state is described in detail below.

Rev: 1.03 7/2014                                           50/62                                                       © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                  GS4288C09/18/36L

Test-Logic-Reset

The test-logic-reset controller state is entered when TMS is held High for at least five consecutive rising edges of TCK. As long as

TMS remains High, the TAP controller will remain in the test-logic-reset state. The test logic is inactive during this state.

Run-Test/Idle

The run-test/idle is a controller state in between scan operations. This state can be maintained by holding TMS Low. From here

either the data register scan, or subsequently, the instruction register scan can be selected.

Select-DR-Scan

Select-DR-scan is a temporary controller state. All test data registers retain their previous state while here.

Capture-DR

The Capture-DR state is where the data is parallel-loaded into the test data registers. If the Boundary Scan Register is the currently

selected register, then the data currently on the pins is latched into the test data registers.

Shift-DR

Data is shifted serially through the data register while in this state. As new data is input through the TDI pin, data is shifted out of

the TDO pin.

Exit1-DR, Pause-DR, and Exit2-DR

The purpose of Exit1-DR is used to provide a path to return back to the run-test/idle state (through the Update-DR state). The

Pause-DR state is entered when the shifting of data through the test registers needs to be suspended. When shifting is to reconvene,

the controller enters the Exit2-DR state and then can re-enter the Shift-DR state.

Update-DR

When the EXTEST instruction is selected, there are latched parallel outputs of the boundary scan shift register that only change

state during the Update-DR controller state.

Instruction Register States

The instruction register states of the TAP controller are similar to the data register states. The desired instruction is serially shifted

into the instruction register during the Shift-IR state and is loaded during the Update-IR state.

                                     Loading Instruction Code and Shifting Out Data

                  T0           T1    T2         T3                T4          T5                 T6                    T7         T8        T9

                                                                                    8-bit Instruction Code

          TCK

          TMS

          TDI

TAP State         Logic-Reset  Idle  Select-DR  Select-IR         Capture-IR  Shift-IR           Shift-IR              Exit 1-IR  Pause-IR  Pause-IR

          TDO

Rev: 1.03 7/2014                                           51/62                                                                  © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                        GS4288C09/18/36L

                             Loading Instruction Code and Shifting Out Data (Continued)

                     T10     T11            T12              T13            T14          T15       T16                       T17        T18                T19

                                                                                                                       n-bit Register between TDI and TDO

TCK

TMS

TDI

TAP State         Exit 2-IR  Update-IR      Select-DR        Capture-DR     Shift-DR     Shift-DR  Shift-DR                  Exit 1-DR  Update-DR          Idle

TDO

                                                       JTAG  Tap   Controller State Diagram

           1         Test Logic Reset

                                  0

                             Run Test Idle  1                      Select DR-scan        1                             Select IR-scan   1

                  0                                                         0                                             0

                                                                1        Capture-DR                1                   Capture-IR

                                                                            0                                             0

                                                                            Shift-DR                                      Shift-IR

                                                                            1            0                                1             0

                                                                            Exit1-DR     1                                Exit1-IR      1

                                                                            0                                             0

                                                                         Pause-DR                                      Pause-IR

                                                                            1            0                                1             0

                                                             0              Exit2-DR               0                      Exit2-IR

                                                                            1                                             1

                                                                         Update-DR                                     Update-IR

                                                                         1            0                                1          0

Rev: 1.03 7/2014                                                   52/62                                                                © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

                                           TAP Controller Block Diagram

                                                       Bypass Regsiter          0

                                               7   6     5  4  3  2     1       0

                               Selection       Instruction Regsiter                             Selection              TDO

                 TDI           circuitry   31  30  29    .  .  .  2     1       0               circuitry

                                               Identification Regsiter

                                           x1  .   .     .  .  .  2     1       0

                                               Boundary Scan Regsiter

       TCK                                        TAP Controller

       TMS

Note:

x= 112 for all configurations

Performing a TAP RESET

A reset is performed by forcing TMS High (VDDQ) for five rising edges of TCK. This RESET does not affect the operation of the

LLDRAM II and may be performed while the LLDRAM II is operating.

At power-up, the TAP is reset internally to ensure that TDO comes up in a High-Z state.

TAP Registers

Registers are connected between the TDI and TDO balls and allow data to be scanned into and out of the LLDRAM II test

circuitry. Only one register can be selected at a time through the instruction register. Data is serially loaded into the TDI ball on the

rising edge of TCK. Data is output on the TDO ball on the falling edge of TCK.

Instruction Register

Eight-bit instructions can be serially loaded into the instruction register. This register is loaded during the Update-IR state of the

TAP controller. Upon power-up, the instruction register is loaded with the IDCODE instruction. It is also loaded with the IDCODE

instruction if the controller is placed in a reset state as described in the previous section.

When the TAP controller is in the Capture-IR state, the two LSBs are loaded with a binary “01” pattern to allow for fault isolation

of the board-level serial test data path.

Bypass Register

To save time when serially shifting data through registers, it is sometimes advantageous to skip certain chips. The bypass register is

a single-bit register that can be placed between the TDI and TDO balls. This allows data to be shifted through the LLDRAM II with

minimal delay. The bypass register is set Low (VSS) when the BYPASS instruction is executed.

Rev: 1.03 7/2014                                  53/62                                                                © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                 GS4288C09/18/36L

Boundary Scan Register

The Boundary Scan Register is connected to all the input and bidirectional balls on the LLDRAM II. Several bits are also included

in the scan register for reserved balls. The LLDRAM II has a 113-bit register.

The Boundary Scan Register is loaded with the contents of the RAM I/O ring when the TAP controller is in the Capture-DR state

and is then placed between the TDI and TDO balls when the controller is moved to the Shift-DR state.

The Boundary Scan Register table shows the order in which the bits are connected. Each bit corresponds to one of the balls on the

LLDRAM II package. The MSB of the register is connected to TDI, and the LSB is connected to TDO.

Identification (ID) Register

The ID register is loaded with a vendor-specific, 32-bit code during the capture-DR state when the IDCODE command is loaded in

the instruction register. The IDCODE is hardwired into the LLDRAM II and can be shifted out when the TAP controller is in the

shift-DR state. The ID register has a vendor code and other information described in the table below.

Identification Register Definitions

Instruction Field                                  Bit Size                                                            Bit Size

Revision number (31:28)                            abcd                                 ab = die revision

                                                                                cd = 00 for x9, 01 for x18, 10 for x36

                                                                                def = 000 for 288Mb, 001 for 576Mb

Device ID (27:12)                    00jkidef10100111                           i = 0 for common I/O, 1 for separate I/O

                                                                                        jk = 01 for LLDRAM II

GSI JEDEC ID code (11:1)             01011011001                                Allows unique identification of LLDRAM II vendor

ID register presence indicator (0)                 1                            Indicates the presence of an ID register

TAP Instruction Set

Overview

Many different instructions (256) are possible with the 8-bit instruction register. All combinations used are listed in the Instruction

Codes table. These six instructions are described in detail below. The remaining instructions are reserved and should not be used.

The TAP controller used in this LLDRAM II is fully compliant to the 1149.1 convention.

Instructions are loaded into the TAP controller during the Shift-IR state when the instruction register is placed between TDI and

TDO. During this state, instructions are shifted through the instruction register through the TDI and TDO balls. To execute the

instruction once it is shifted in, the TAP controller needs to be moved into the Update-IR state.

EXTEST

The EXTEST instruction allows circuitry external to the component package to be tested. Boundary Scan Register cells at output

balls are used to apply a test vector, while those at input balls capture test results. Typically, the first test vector to be applied using

the EXTEST instruction will be shifted into the Boundary Scan Register using the PRELOAD instruction. Thus, during the

Update-IR state of EXTEST, the output driver is turned on, and the PRELOAD data is driven onto the output balls.

IDCODE

The IDCODE instruction causes a vendor-specific, 32-bit code to be loaded into the instruction register. It also places the

instruction register between the TDI and TDO balls and allows the IDCODE to be shifted out of the device when the TAP

controller enters the Shift-DR state. The IDCODE instruction is loaded into the instruction register upon power-up or whenever the

TAP controller is given a test logic reset state.

Rev: 1.03 7/2014                                             54/62                                                               © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                              GS4288C09/18/36L

High-Z

The High-Z instruction places all LLDRAM II outputs into a High-Z state, and causes the bypass register to be connected between

TDI and TDO when the TAP Controller is in the Shift DR state.

CLAMP

When the CLAMP instruction is loaded into the instruction register, the data driven by the output balls are determined from the

values held in the Boundary Scan Register. Additionally, it causes the bypass register to be connected between TDI and TDO

when the TAP Controller is in the Shift DR state.

SAMPLE/PRELOAD

When the SAMPLE/PRELOAD instruction is loaded into the instruction register and the TAP controller is in the Capture-DR

state, a snapshot of data on the inputs and bidirectional balls is captured in the Boundary Scan Register.

The user must be aware that the TAP controller clock can only operate at a frequency up to 50 MHz, while the LLDRAM II clock

operates significantly faster. Because there is a large difference between the clock frequencies, it is possible that during the

Capture-DR state, an input or output will undergo a transition. The TAP may then try to capture a signal while in transition

(metastable state). This will not harm the device, but there is no guarantee as to the value that will be captured. Repeatable results

may not be possible.

To ensure that the Boundary Scan Register will capture the correct value of a signal, the LLDRAM II signal must be stabilized long

enough to meet the TAP controller’s capture setup plus hold time (tCS + tCH). The LLDRAM II clock input might not be captured

correctly if there is no way in a design to stop (or slow) the clock during a SAMPLE/PRELOAD instruction. If this is an issue, it is

still possible to capture all other signals and simply ignore the value of the CK and CK captured in the Boundary Scan Register.

Once the data is captured, it is possible to shift out the data by putting the TAP into the Shift-DR state. This places the Boundary

Scan Register between the TDI and TDO balls.

BYPASS

When the BYPASS instruction is loaded in the instruction register and the TAP is placed in a Shift-DR state, the bypass register is

placed between TDI and TDO. The advantage of the BYPASS instruction is that it shortens the boundary scan path when multiple

devices are connected together on a board.

Reserved for Future Use

The remaining instructions are not implemented but are reserved for future use. Do not use these instructions.

                                                              TAP Timing

                                T0                 T1                       T2         T3                                     T4        T5

                                                                     tTLTH

                                                       tTHTL                    tTHTH

        Test Clock (TCK)

                                                              tTHMX

                                                       tMVTH

        Test Mode Select (TMS)

                                                              tTHDX

                                                       tDVTH

        Test Data-In (TDI)

                                                                                                                       tTLOX

                                                                                                                       tTLOV

        Test Data-Out (TDO)

Rev: 1.03 7/2014                                              55/62                                                           © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                   GS4288C09/18/36L

TAP Input AC Logic Levels

                  Description                          Symbol             Min                                               Max    Units

       Input High (logic 1) Voltage                           VIH         VREF + 0.3                                        —          V

                  Input Low (logic 0) Voltage                 VIL         —                                            VREF – 0.3      V

TAP AC Electrical Characteristics

       Description                             Symbol                Min                                               Max         Units

                                                              Clock

       Clock Cycle Time                        tTHTH                 20                                                —           ns

       Clock Frequency                         tTF                   —                                                 50          MHz

       Clock High Time                         tTHTL                 10                                                —           ns

       Clock Low Time                          tTLTH                 10                                                —           ns

                                                       TDI/TDO Times

TCK Low to TDO Unknown                         tTLOX                 0                                                 —           ns

       TCK Low to TDO Valid                    tTLOV                 —                                                 10          ns

       TDI Valid to TCK High                   tDVTH                 5                                                 —           ns

       TCK High to TDI Invalid                 tTHDX                 5                                                 —           ns

                                                       Setup Times

       TMS Setup                               tMVTH                 5                                                 —           ns

       Capture Setup                           tCS                   5                                                 —           ns

                                                       Hold Times

       TMS Setup                               tTHMX                 5                                                 —           ns

       Capture Setup                           tCH                   5                                                 —           ns

Note:

tCS and tCH refer to the set up and hold time requirements of latching data from the Boundary Scan Register.

Rev: 1.03 7/2014                                       56/62                                                                       © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                            GS4288C09/18/36L

TAP DC Electrical Characteristics and Operating Conditions

        Description                        Condition      Symbol  Min                                                  Max  Units              Notes

    Input High (logic 1) Voltage           —              VIH     VREF + 0.15                    VDD + 0.3                  V                  1, 2

    Input High (logic 0) Voltage           —              VIL     VSS – 0.3                      VREF – 0.15                V                  1, 2

    Input Leakage Current               Output disabled,  ILI     –5.0                                                 5.0                   —

                                        0 VVIN VDDQ

    Output Leakage Current              0 VVIN VDD    ILO     –5.0                                                 5.0                   —

        Output Low Voltage              IOLC = 100      VOL1    —                                                    0.2  V                  1

        Output Low Voltage                 IOLT = 2mA     VOL2    —                                                    0.4  V                  1

        Output High Voltage             IOHC = 100    VOH1    VDDQ – 0.2                                           —    V                  1

        Output High Voltage                IOHT= 2mA    VOH2    VDDQ – 0.4                                           —    V                  1

Notes:

1.  All voltages referenced to VSS (GND).

2.  Overshoot = VIH(AC) VDD + 0.7 V for t tTHTH/2;    undershoot = VIL(AC)– 0.5 V for  t  tTHTH/2; during          normal operation,  VDDQ must

    not exceed VDD.

Scan Register Sizes

                  Register Name                                                                  Bit Size

                     Instruction                                                                 8

                     Bypass                                                                      1

                     ID                                                                          32

                  Boundary Scan                                                                  113

JTAG TAP Instruction         Codes

    Instruction                   Code                                  Description

        EXTEST               0000 0000     Captures I/O ring contents; Places the Boundary Scan Register between TDI and TDO. Data

                                           driven by output balls are determined from values held in the Boundary Scan Register.

        IDCODE               0010 0001     Loads the ID register with the vendor ID code and places the register between TDI and TDO. This

                                           operation does not affect LLDRAM II operations.

SAMPLE/PRELOAD               0000 0101     Captures I/O ring contents. Places the Boundary Scan Register between TDI and TDO. This

                                           operation does not affect LLDRAM II operations.

        CLAMP                0000 0111     Selects the bypass register to be connected between TDI and TDO. Data driven by output balls are

                                           determined from values held in the Boundary Scan Register.

        HIGH-Z               0000 0011     Selects the bypass register to be connected between TDI and TDO. All outputs are forced into

                                           High-Z.

        BYPASS               1111 1111     Places Bypass Register between TDI and TDO.This operation does not affect LLDRAM II

                                           operations.

Rev: 1.03 7/2014                                          57/62                                                             © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                              GS4288C09/18/36L

Boundary Scan Exit Order

Bit #                       Ball                    Bit #  Ball                                                        Bit #  Ball

1                           K1                      39     R11                                                         77     C11

2                           K2                      40     R11                                                         78     C11

3                           L2                      41     P11                                                         79     C10

4                           L1                      42     P11                                                         80     C10

5                           M1                      43     P10                                                         81     B11

6                           M3                      44     P10                                                         82     B11

7                           M2                      45     N11                                                         83     B10

8                           N1                      46     N11                                                         84     B10

9                           P1                      47     N10                                                         85     B3

10                          N3                      48     N10                                                         86     B3

11                          N3                      49     P12                                                         87     B2

12                          N2                      50     N12                                                         88     B2

13                          N2                      51     M11                                                         89     C3

14                          P3                      52     M10                                                         90     C3

15                          P3                      53     M12                                                         91     C2

16                          P2                      54     L12                                                         92     C2

17                          P2                      55     L11                                                         93     D3

18                          R2                      56     K11                                                         94     D3

19                          R3                      57     K12                                                         95     D2

20                          T2                      58     J12                                                         96     D2

21                          T2                      59     J11                                                         97     E2

22                          T3                      60     H11                                                         98     E2

23                          T3                      61     H12                                                         99     E3

24                          U2                      62     G12                                                         100    E3

25                          U2                      63     G10                                                         101    F2

26                          U3                      64     G11                                                         102    F2

27                          U3                      65     E12                                                         103    F3

28                          V2                      66     F12                                                         104    F3

29                          U10                     67     F10                                                         105    E1

30                          U10                     68     F10                                                         106    F1

31                          U11                     69     F11                                                         107    G2

32                          U11                     70     F11                                                         108    G3

33                          T10                     71     E10                                                         109    G1

34                          T10                     72     E10                                                         110    H1

35                          T11                     73     E11                                                         111    H2

36                          T11                     74     E11                                                         112    J2

37                          R10                     75     D11                                                         113    J1

38                          R10                     76     D10                                                         —      —

Boundary Scan (BSDL Files)

For information regarding the Boundary Scan Chain, or to obtain BSDL files for this part, please contact our Applications

Engineering Department at: apps@gsitechnology.com.

Rev: 1.03 7/2014                                    58/62                                                                     © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                       GS4288C09/18/36L

                                       Package Dimensions—144-Bump BGA (Package L)

                                                                                                                                A1

                                                                                                   1                   2  3  4  5   6  7   8  9  10  11  12

                                                                                                A

                                                                                                B

                                                                                                C

                                                                                                D

                                                                                                E

                                                                                                F

                                                                                                G

                                                     10.60    CTR.                              H

                                                                       10° TYP.     0.73±0.1    J

                                                                                                K

                                                                                                L

SEATING PLANE                                                                                   M

                  0.012  A                 A                                                    N

                                                                                                P

                                                                                                R

                                                                                                T

                                                                                                U

                                                                                                V

Ø0.51 (144x)                                         8.80

                                                                                    A1

                                                                    0.80 TYP.                                                   0.49±0.05

                                   12  11  10  9  8  7     6  5     4  3  2   1

                                                                                 A

                         1.0 TYP.                                                B

                                                                                 C

                                                                                 D

                                                                                 E

                                                                                 F

                                                                                 G

17.00 CTR                                                                        H  18.50±0.10                               18.1 CTR

                                                                                 J

                                                                                 K

                                                                                 L

                                                                                 M

                                                                                 N

                                                                                 P

                                                                                 R

                                                                                 T

                                                                                 U

                                                                                 V

                                                                                                                                1.20 MAX

                                                           0.8 TYP

                                                                                                                             0.34 MIN

                                                  8.8 CTR

                                                  11.00±0.10                        Note:       All dimensions in millimeters.

Rev: 1.03 7/2014                                                       59/62                                                                  © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Ordering Information for GSI LLDRAM IIs

    Org           Part Number1                Type                                Package                                  Speed      T2

                                                                                                                           (tCK/tRC)

    32M x 9       GS4288C09L-18               CIO LLDRAM II                       144-ball BGA                            533/15     C

    32M x 9       GS4288C09L-24               CIO LLDRAM II                       144-ball BGA                            400/15     C

    32M x 9       GS4288C09L-25               CIO LLDRAM II                       144-ball BGA                            400/20     C

    32M x 9       GS4288C09L-33               CIO LLDRAM II                       144-ball BGA                            300/20     C

    16M x 18      GS4288C18L-18               CIO LLDRAM II                       144-ball BGA                            533/15     C

    16M x 18      GS4288C18L-24               CIO LLDRAM II                       144-ball BGA                            400/15     C

    16M x 18      GS4288C18L-25               CIO LLDRAM II                       144-ball BGA                            400/20     C

    16M x 18      GS4288C18L-33               CIO LLDRAM II                       144-ball BGA                            300/20     C

    8M x 36       GS4288C36L-18               CIO LLDRAM II                       144-ball BGA                            533/15     C

    8M x 36       GS4288C36L-24               CIO LLDRAM II                       144-ball BGA                            400/15     C

    8M x 36       GS4288C36L-25               CIO LLDRAM II                       144-ball BGA                            400/20     C

    8M x 36       GS4288C36L-33               CIO LLDRAM II                       144-ball BGA                            300/20     C

    32M x 9       GS4288C09GL-18              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             533/15     C

    32M x 9       GS4288C09GL-24              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/15     C

    32M x 9       GS4288C09GL-25              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/20     C

    32M x 9       GS4288C09GL-33              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             300/20     C

    16M x 18      GS4288C18GL-18              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             533/15     C

    16M x 18      GS4288C18GL-24              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/15     C

    16M x 18      GS4288C18GL-25              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/20     C

    16M x 18      GS4288C18GL-33              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             300/20     C

    8M x 36       GS4288C36GL-18              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             533/15     C

    8M x 36       GS4288C36GL-24              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/15     C

    8M x 36       GS4288C36GL-25              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/20     C

    8M x 36       GS4288C36GL-33              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             300/20     C

    32M x 9       GS4288C09L-18I              CIO LLDRAM II                       144-ball BGA                            533/15     I

    32M x 9       GS4288C09L-24I              CIO LLDRAM II                       144-ball BGA                            400/15     I

    32M x 9       GS4288C09L-25I              CIO LLDRAM II                       144-ball BGA                            400/20     I

Note:

1.  Customers requiring delivery in Tape and  Reel should add the character  “T”  to the end of the part number. Example:  GS4288C09-533T.

2.  C = Commercial Temperature Range. I =     Industrial Temperature Range.

Rev: 1.03 7/2014                              60/62                                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                       GS4288C09/18/36L

Ordering Information for GSI LLDRAM IIs (Continued)

    Org           Part Number1                Type                                Package                                  Speed      T2

                                                                                                                           (tCK/tRC)

    32M x 9       GS4288C09L-33I              CIO LLDRAM II                       144-ball BGA                            300/20     I

    16M x 18      GS4288C18L-18I              CIO LLDRAM II                       144-ball BGA                            533/15     I

    16M x 18      GS4288C18L-24I              CIO LLDRAM II                       144-ball BGA                            400/15     I

    16M x 18      GS4288C18L-25I              CIO LLDRAM II                       144-ball BGA                            400/20     I

    16M x 18      GS4288C18L-33I              CIO LLDRAM II                       144-ball BGA                            300/20     I

    8M x 36       GS4288C36L-18I              CIO LLDRAM II                       144-ball BGA                            533/15     I

    8M x 36       GS4288C36L-24I              CIO LLDRAM II                       144-ball BGA                            400/15     I

    8M x 36       GS4288C36L-25I              CIO LLDRAM II                       144-ball BGA                            400/20     I

    8M x 36       GS4288C36L-33I              CIO LLDRAM II                       144-ball BGA                            300/20     I

    32M x 9       GS4288C09GL-18I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             533/15     I

    32M x 9       GS4288C09GL-24I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/15     I

    32M x 9       GS4288C09GL-25I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/20     I

    32M x 9       GS4288C09GL-33I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             300/20     I

    16M x 18      GS4288C18GL-18I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             533/15     I

    16M x 18      GS4288C18GL-24              CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/15     I

    16M x 18      GS4288C18GL-25I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/20     I

    16M x 18      GS4288C18GL-33I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             300/20     I

    8M x 36       GS4288C36GL-18I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             533/15     I

    8M x 36       GS4288C36GL-24I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/15     I

    8M x 36       GS4288C36GL-25I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             400/20     I

    8M x 36       GS4288C36GL-33I             CIO LLDRAM II                       RoHS-compliant 144-ball BGA             300/20     I

Note:

1.  Customers requiring delivery in Tape and  Reel should add the character  “T”  to the end of the part number. Example:  GS4288C09-533T.

2.  C = Commercial Temperature Range. I =     Industrial Temperature Range.

Rev: 1.03 7/2014                              61/62                                                                        © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
                                                                                                                                 GS4288C09/18/36L

288Mb  LLDRAM II Datasheet  Revision History

       File Name            Types of Changes                                                                           Revision

                            Format or Content

                                               •      Creation of new datasheet

                                               •      (Rev1.00a:  Corrected mechanical drawing)

       4288Cxx_r1                              •      (Rev1.00b:  Editorial updates)

                                               •      (Rev1.00c: Updated NOP commands from 3000 to                               2048)

                                               •      (Rev1.00d:  Changed all VSSQ references to VSS)

                                               •      Added IDD Current numbers

       4288Cxx_r1_01                           •      Added thermal numbers

                                               •      Changed number of NOP commands from 2048 to                                1024

                                               •      (Rev1.01a:  Corrected NOP command on page 7)

       4288Cxx_r1_02                           •      Changed DLL Reset to 5s for 200MHz (page 10)

                                               •      Corrected typos/wording errors in TAP section

       4288Cxx_r1_03                           •      Updated datasheet to reflect MP status

Rev: 1.03 7/2014                               62/62                                                                             © 2011, GSI Technology

Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

GSI Technology:

GS4288C18GL-25I  GS4288C18GL-24I  GS4288C36GL-25I  GS4288C36GL-24I

小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2019 EEWORLD.com.cn, Inc. All rights reserved