电子工程世界电子工程世界电子工程世界

产品描述

搜索

G9S-301 DC24

器件型号:G9S-301 DC24
器件类别:机电产品    工业自动化    控制器   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

控制器 SAFE RELAY 3PST-NO DC24

参数
产品属性属性值
制造商:Omron
产品种类:控制器
发货限制:Mouser目前不销售该产品。
RoHS:详细信息
系列:G9S
商标:Omron Automation and Safety
产品类型:Controllers
工厂包装数量:1
子类别:Controllers
零件号别名:G9S301DC24

G9S-301 DC24器件文档内容

G9S

   Safety Relay Unit

Ideal for Safety Door and Emergency

Stop Switch Circuits

H  Three-pole models are only 67.5 mm wide;

   five-pole models only 90 mm wide are

   available

H  OFF-delay feature models available

H  Incorporates LED indicators for monitoring

   built-in relays

H  Finger-protection construction

H  DIN-track mounting

H  Conforms to EN60204-1 (IEC60204-1),

   EN954-1, and approved by BIA

Note:  Be sure to refer to the Precautions Section.

Ordering Information

J  BASIC MODELS

Number of poles  Main contact         Number of input channels         Category               Rated voltage  Part number

                 form

3 (See Note)     3PST-NO              1 channel or 2 channels          4                      24 VDC         G9S-301

                                      possible                                                24 VAC

                                                                                              100 VAC

                                                                                              120 VAC

                                                                                              200 VAC

                                                                                              240 VAC

5 (See Note)     5PST-NO                                                                      24 VDC         G9S-501

                                                                                              24 VAC

                                                                                              100 VAC

                                                                                              120 VAC

                                                                                              200 VAC

                                                                                              240 VAC

Note:  Auxiliary contact is SPST-NC.

J  OFF-DELAY MODELS

Number of     Main          OFF-delay       Number of input         Category     OFF-delay       Rated       Part number

poles         contact form  form            channels                             time            voltage

3             3PST-NO       DPST-NO         1 channel or 2          3            1 s, 1.5 s,     24 VDC      G9S-321-T01, -T015,

                                            channels possible                    3 s, 4 s, 5 s,  24 VAC      -T03, -T04, -T05, -T06,

                                                                                 6 s, 10 s, 30               -T10, -T30

                                                                                 s               100 VAC

                                                                                                 120 VAC

                                                                                                 200 VAC

                                                                                                 240 VAC

Note:  Each model has an SPST-NC auxiliary contact.

       When ordering, specify the voltage.

                 Example: G9S-301 24 VDC

                                                     Rated voltage

                                                                    2
                                                                                                                          G9S

J   MODEL NUMBER LEGEND

            G9S-jjj-jjj

                     1  2  3  4

1.  Contact Configuration (Safety Output)                            4.  OFF-Delay Time

    3:   3PST-NO                                                         None: No OFF-delay

    5:   5PST-NO                                                         T01:      1 second

2.  Contact Configuration (OFF-delay Output)                             T015:     1.5 seconds

    0:   None                                                            T03:      3 seconds

    2:   DPST-ND                                                         T04:      4 seconds

3.  Contact Configuration (Auxiliary Output)                             T05:      5 seconds

    0:   None                                                            T06:      6 seconds

    1:   SPST-NC                                                         T10:      10 seconds

                                                                         T30:      30 seconds

Specifications

J RATINGS

Controller Block                                                     Contact

Model       Rated          Rated current      Rated power            Item                    G9S-301

            voltage                           consumption                                    G9S-501

G9S-301     24 VDC         62.5 mA±20%        Approx. 1.5 W                                  G9S-321-Tj

            24 VAC         125 mA±20%         Approx. 3 VA           Rated load              3 A at 240 VAC; (see note)

                           30 mA±20%          (60 Hz)                                        cosφ = 0.4

            100 VAC                                                      AC15                3 A at 240 VAC; cosφ = 0.3;

            120 VAC        25.0 mA±20%                                   (IEC-947-5-1/       6,050 operations

            200 VAC        15 mA±20%                                     Table 4)

            240 VAC        12.5 mA±20%                                   DC13                1 A at 24 VDC; L/R=100 ms;

G9S-501     24 VDC         127 mA±20%         Approx. 3 W                (IEC-947-5-1/       6,050 operations

                           229 mA±20%                                    Table 4)

            24 VAC                            Approx. 5.5 VA         Rated carry             5A

            100 VAC        55 mA±20%          (60 Hz)                current

            120 VAC        45.8 mA±20%                               Max. switching          250 VAC, 24 VDC

            200 VAC        27.5 mA±20%                               voltage

            240 VAC        22.9 mA±20%                               Max. switching          AC: 1,250 VA;

G9S-321-Tj  24 VDC         150 mA±20%         Approx. 3.6 W          power                   DC: 120 W

            24 VAC         254 mA±20%         Approx. 6.1 VA         Min. permissible        50 mA at 24 VDC

            100 VAC        61 mA±20%          (60 Hz)                load                    (operating frequency: 60 operations/min.)

            120 VAC        50.8 mA±20%                               Note:  If the load is 5 A at 240 VAC, the service life will be 40,000

            200 VAC        30.5 mA±20%                                      operations.

            240 VAC        25.4 mA±20%

Note:   The above ratings are at an ambient temperature of 23°C.

                                                                  3
G9S

J  CHARACTERISTICS

Item                                                       G9S-301                    G9S-501              G9S-321-Tj

Input voltage/frequency                                    24 VDC; 24 VAC, 50/60 Hz; 100 VAC, 50/60 Hz; 120 VAC, 50/60 Hz;

                                                           200 VAC, 50/60 Hz; 240 VAC, 50/60 Hz

Supply voltage range                                       85% to 110% of rated input voltage

Fuse protection                                            0.4 A

Contact form of safety circuit                             3PST-NO                    5PST-NO              3PST-NO

Contact form of auxiliary circuit                          SPST-NC                    SPST-NC              SPST-NC

Contact form of safety OFF-delay circuit                   —                                               DPST-NO

Contact resistance (see note1)                             300 mΩ max.

Operate time                (Rated voltage operation,      300 ms max.                                     300 ms

Release time                does not include bounce time)  100 ms max.                                     100 ms (except

                                                                                                           OFF-delay output)

Max. switching              Mechanical                     1,800 operations/hr

frequency                   Rated load                     1,800 operations/hr

Insulation resistance (at 500 VDC)                         100 MΩ min. between control circuit and the safety and auxiliary circuits,

                                                           between the safety circuits and auxiliary circuits, and between safety circuits

Rated insulation voltage                                   250 V

           P.D. 3 (outside), P.D. 2 (inside)

           (IEC664-1, DIN VDE 0110/’89)

Rated impulse withstand voltage                            4 kV

           Overvoltage category 3

           (IEC664-1, DIN VDE 0110/’89)

Dielectric strength                                        2,500 VAC (50/60 Hz for 1 min.) between control circuit and the safety       and

                                                           auxiliary circuits, between the safety circuits and auxiliary circuits, and

                                                           between safety circuits

Vibration resistance        Destruction                    10 to 55 Hz, 0.75-mm double amplitude

(IEC68-2-6)                 Malfunction                    10 to 55 Hz, 0.5-mm double amplitude

Shock resistance            Destruction                    300 m/s2 for 11 ms

(IEC68-2-27)                Malfunction                    50 m/s2 for 11 ms

Min. permissible load (reference value)                    24 VDC, 50 mA (24 VDC, 4 mA photocoupler load)

Ambient temperature                                        Operating:   --25°C to 55°C (with no icing or condensation)

                                                           Storage:  --25°C to 85°C (with no icing or condensation)

Ambient humidity                                           Operating:   35% to 85%

                                                           Storage:  35% to 85%

Degree of protection        Terminals                      IP20

(IEC529)                    Enclosure                      IP40

Terminal tightening torque                                 0.98 N S m

Weight (see note 2)                                        Approx. 365 g              Approx. 550 g        Approx. 580 g

Approved standards                                         UL508, CSA22.2 No. 14, EN954-1, EN60204-1

EMC                                                        EMI:   EN55011 group 1 class A

                                                           EMS:   EN50082-2

Note: 1.  Measurement conditions: 10 mA at 5 VDC using the fall-of-potential method.

      2.  These weights are for DC models. AC models are 200 g heavier.

                                                                     4
                                                                                                                                                    G9S

J LIFE EXPECTANCY

Mechanical life                                                 1,000,000 operations min. with a switching frequency of approx. 1,800 operations/h

Electrical life                                                 100,000 operations min. at the rated load with a switching frequency of approx. 1,800 operations/h

Life Expectancy Curve
(240 VAC, cosφ = 0.4)

Life expectancy (x104 operations)        G9S (three-pole and

                                         five-pole models)

                                         Switching current (A)

Application Examples

J G9S-301 (24 VDC) WITH 2-CHANNEL                                         LIMIT  SWITCH  INPUT

                                                                                             Timing Chart

                                                                                             Limit switches

                                                                                             S1 and S2

                                                                                             Starter switch

                                                                                             S3

                                                                Feedback                     K3 (NC)

                                                                loop

                                                                                             K3 (NO)

                                                                                             K1 and K2

                                                                                             (NC)

                                   Open                                                      K1 and K2

                                                                                             (NO)

                                                                                             KM1 and KM2

                                                                                             (NC)

                                                                                             KM1 and KM2

                                                                                             (NO)

                                                                                             PC input

                                                                                             PC output

                                                                                             KM3

                                                                                         S1:                 Limit switch

                                                                                         S2:                 Safety Limit Switch

                                                                                                             with positive opening mechanism

                                                                                                             (D4D and D4B)

                                                                                         S3:                 Starter switch

                                                                                         KM1 and KM2:        Magnet Contactor

                                                                                         KM3:                G3J Solid-state Contactor

                                                                                         M:                  3-phase motor

                                                                                 5
G9S

J  G9S-501  (AC  MODEL) WITH    2-CHANNEL      LIMIT             SWITCH INPUT

                                                                 Timing Chart

                                                                 Limit switches

                                                                 S1 and S2

                                                                 Starter switch

                 Feedback                                        S3

                 loop                                            K3 (NC)

                                                                 K3 (NO)

                                                                 K1 and K2

Open                                                             (NC)

                                                                 K1 and K2

                                                                 (NO)

                                                                 K4 and K5

                                                                 (NC)

                                                                 K4 and K5

                                                                 (NO)

                                                                 KM1 and KM2

                                                                 (NC)

                                                                 KM1 and KM2

                                                                 (NO)

                                                                 S1:                 Limit switch

                                                                 S2:                 Safety Limit Switch

                                                                                     with positive opening  mechanism

                                                                                     (D4D and D4B)

                                                                 S3:                 Starter switch

                                                                 KM1 and KM2:        Magnet Contactor

                                                                 M:                  3-phase motor

J  G9S-321-Tj    (24 VDC) WITH  2-CHANNEL      LIMIT             SWITCH INPUT

                                                                      Timing Chart

                                                                     Limit switches

                                                                     S1 and S2

                                                                     Starter switch

                                                                     S3

                                                                     K3 (NC)

                                Feedback loop                        K3 (NO)

Open                                                                 K1 and K2

                                                                     (NC)

                                                                     K1 and K2

                                                                     (NO)

                                                                     K4 and K5

                                                                     (NC)

                                                                     K4 and K5

                                                                     (NO)

                                OFF-delay                            KM1 and KM2

                                timer                                (NC)

                                                                     KM1 and KM2

                                                                     (NO)

                                                                     Operation

                                                                     instruction

                                                                     Motor rotation

                                                                                     OFF-delay time

                                                                 S1:                 Limit switch

                                Operation                        S2:                 Safety Limit Switch

                                instruction    Motor controller                      with positive opening mechanism

                                                                                     (D4D and D4B)

                                                                 S3:                 Starter switch

                                                                 KM1 and KM2:        Magnet Contactor

                                                                 M:                  3-phase motor

                                               6
                                                                                                G9S

J G9S-301  (24  VDC)  WITH 2-CHANNEL  EMERGENCY   STOP SWITCH INPUT

                                                       Timing Chart

                                                  Emergency stop

                                                  switch S1

                      Feedback                    Starter switch

                      loop                        S2

                                                  K3 (NC)

                                                  K3 (NO)

                                                  K1 and K2

                                                  (NC)

                                                  K1 and K2

                                                  (NO)

                                                  KM1 and KM2

                                                  (NC)

                                                  KM1 and KM2

                                                  (NO)

                                                  PC input

                                                  PC output

                                                  KM3

                                                  S1:                Emergency stop switch

                                                  S2:                Starter switch

                                                  KM1 and KM2:       Magnet Contactor

                                                  KM3:               G3J Solid-state Contactor

                                                  M:                 3-phase motor

J G9S-301  (24  VDC)  WITH 2-CHANNEL  AUTO-RESET  LIMIT SWITCH    INPUT

                                                  Timing Chart

                                                  Limit switches

                                                  S1 and S2 (NC)

                                                  Limit switches

                                                  S1 and S2 (NO)

                                                  K3 (NC)

                            Feedback

                            loop                  K3 (NO)

                                                  K1 and K2

                                                  (NC)

Open                                              K1 and K2

                                                  (NO)

                                                  KM1 and KM2

                                                  (NC)

                                                  KM1 and KM2

                                                  (NO)

                                                  S1:             Limit switch

                                                  S2:             Safety Limit Switch

                                                                  with positive opening mechanism

                                                                  (D4D and D4B)

                                                  KM1 and KM2:    Magnet Contactor

                                                  M:              3-phase motor

                                      7
G9S

Dimensions

Unit: mm (inch)

J  G9S-301

                          92

                         (3.62)

                                             Eighteen, M3.5

                                             5.9

                          61.2

                 76 max.

                 (2.99)

                                 7                           111 max.

                                    56                       (4.37)

                                    68 max.

                                    (2.68)

J  G9S-321-Tj

   G9S-501

                         92

                 (3.62)

                                                  Twenty-four, M3.5
                                                  5.9

                          63

                 76 max.

                 (2.99)

                                 7  10                       111 max.

                                        80                           (4.37)

                                    91 max.

                                    (3.58)

                                        8
                                                                     G9S

Installation

J INTERNAL CONNECTIONS

G9S-301 (24 VDC)                   G9S-301 (AC Model)

G9S-501 (24 VDC)                   G9S-501 (AC Model)

G9S-321-Tj (24 VDC)                G9S-321-Tj (AC Model)

                     OFF-delay                            OFF-delay

                     timer                                timer

                                9
G9S

J  EXTERNAL CONNECTIONS

G9S-301 Models

G9S-321 and G9S-501 Models

                            10
                                                                                                                                          G9S

Precautions

J WIRING                                                                  J  APPLICABLE SAFETY CATEGORY

Be sure to turn off the G9S before wiring. Do not touch its                  (EN954-1)

terminals while the power is turned on because the terminals are          All G9S-series Relays fall under Safety Category 4 of EN954-1

charged and may cause an electric shock.                                  except the G9S-321-T. The G9S-321-T has an OFF-delay output

Use the following to wire the G9S.                                        block falling under Safety Category 3.

Strand wire:  0.75 to 1.5 mm2 16 to 18 AWG                                The above is provided according to circuit examples presented

Steel wire:   1.0 to 1.5 mm2 16 to 18 AWG                                 by OMRON. Therefore, the above may not apply to all operating

Tighten each screw to a torque of 0.78 to 1.18 NSm (8 to                  environments.

12 kgfScm), or the G9S may malfunction or generate heat.                  The applicable safety category is determined from the whole

External inputs connected to T11 and T12 or T21 and T22 of the            safety control system. Make sure that the whole safety control

G9S-301 must be no-voltage contact inputs.                                system meets EN954-1 requirements.

PE is a ground terminal.                                                  Safety Category 4 of EN954-1

                                                                          Apply 2-channel external input to the T11 and T12 terminals and

When a machine is grounded at the positive, the PE terminal               T21 and T22 terminals through switches each incorporating a

should not be grounded.                                                   force-separation mechanism. If limit switches are used, make

                                                                          sure that at least one of them incorporates a force-separation

J MOUNTING MULTIPLE UNITS                                                 mechanism.

If the output current is 3 A or more, make sure that there is a           Refer to Application Examples and input a signal for the

minimum distance of 50 mm (1.97 in) each between all adjacent             normally-closed contact of the contactor (i.e., input to X1 of the

G9S Units. (24-VDC models do not require this spacing.)                   G9S-301, X2 of the G9S-501, or X2 of the G9S-321-T).

              50 mm min.                                                  Be sure to ground the PE terminal. If the relay is operating with

              (1.97)                                                      DC, the power supply may be grounded instead.

J FUSE REPLACEMENT

Three- and Five-Pole Models

The power input circuit of the G9S includes a fuse to protect the it

from damage that may be caused by short-circuiting. The fuse is

mounted to the side panel. Use the following type of fuse as a

replacement.

Littel Fuse 218.4 (rated current 0.4 A), IEC127 approval.

Use a flat-blade screwdriver to remove the fuse cover.

Be sure to turn off the G9S before replacing the fuse.

Fuse

                                                                      11
ALL DIMENSIONS SHOWN ARE                      IN MILLIMETERS. To convert millimeters into inches, divide by 25.4

OMRON ELECTRONICS LLC                         OMRON CANADA, INC.        OMRON ON-LINE

One Commerce Drive                            885 Milner Avenue         Global - http://www.omron.com

Schaumburg, IL 60173                          Toronto, Ontario M1B 5V8  USA - http://www.omron.com/oei

847-843-7900                                  416-286-6465              Canada - http://www.omron.ca

For US technical support or other inquiries:

800-556-6766

Cat. No. GC SAFETY-2  2/03                    Specifications subject to change without notice  Printed in USA
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

G6D4SB     G79Y100C  G9S-2002 DC24     G9S-2001 DC24  G9S-301 AC100  G9S-301 AC120  G9S-301 AC200    G9S-

301 AC24   G9S-301 AC240  G9S-301 DC24  G9S-321-T015 DC24      G9S-321-T01 AC100  G9S-321-T01 AC120  G9S-

321-T01 AC200  G9S-321-T01 AC24  G9S-321-T01 AC240    G9S-321-T01 DC24  G9S-321-T03 DC24    G9S-321-T04

DC24   G9S-321-T10 AC100  G9S-321-T10 AC120  G9S-321-T10 AC200  G9S-321-T10 AC24    G9S-321-T10 AC240

G9S-321-T10 DC24  G9S-321-T30 AC100     G9S-321-T30 AC120  G9S-321-T30 AC200      G9S-321-T30 AC24  G9S-321-

T30 AC240  G9S-321-T30 DC24  G9S-501 AC100   G9S-501 AC120     G9S-501 AC200  G9S-501 AC24  G9S-501

AC240  G9S-501 DC24     G9SA-321-T075  G9SA-321-T30 AC100-240
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved