Power Controllers                                                                                CSM_G3PX_DS_E_2_1

G3PX

Single-phase Models

EUN Series
AC Power Controllers with Phase-control
System Allow Precise Temperature Control
Models with Base-up and Soft-start
Functions

EH Series
Phase Control System Makes It Possible to
Detect Single Heater Open Circuit (EH
Series) and Multiple Heater Open Circuits
(EHN Series)

EC Series
Optimum Devices for Controlling Input
Power for Pure Metal Heater, and
Incorporating Overcurrent Detecting and
Single Heater Open Circuit Detecting
Functions

OMRON's unique design and carefully-selected materials made
it possible to produce a compact and lightweight Power
Controller.

Replaceable, easy-to-install Power Device Cartridge assures
ease of maintenance.

Detecting component failures and operating errors.
Certified by UL and CSA.

     Refer to Safety Precautions for All Power
     Controllers.

Model Number Structure

Model Number Legend

G3PX-@@@@-@

     1 2345 6

1. Basic Model Name                                            5. Functions

G3PX: Power Controller                                         UN:  Simple models

2. Rated Load Power Supply Voltage                             H:   Single heater open circuit detection function

2:   100/110 VAC and 200/230 VAC                               HN:  Multiple heater open circuit detection function

3. Rated Load Current                                          C:   Constant-current function

20:  20 A                                                      6. CT Unit Type

40:  40 A                                                      Note: Refer to CT Unit on page 4.

60:  60 A

4. Number of Phases

E:   Single

                                                                                                                     1
                                                              G3PX

G3PX Cartridge

G32X-@@

1 23

1. Basic Model Type

G32X: Accessory for G3PX

2. Basic Model Name

A:         Power Device Cartridge

3. Rated Load Current

20:        20 A

40:        40 A

60:        60 A

CT Unit

G32X-@@@

     1 234

1. Basic Model Type

G32X: Accessory for G3PX

2. Basic Model Name

CT:        CT Unit

3. Length of Lead Wires

03:        30 cm

10:        100 cm

4. Series

Blank: Series for single heater open circuit detection

HN:        Series for multiple heater open circuit detection

C:         Series for constant current

Variable Resistor

G32X-@

     12

1. Basic Model Type
    G32X: Accessory for G3PX

2. Basic Model Name
    V3K: 3-k Variable Resistor
    V2K: 2-k Variable Resistor

                                                                    2
                                                                                                                       G3PX

Ordering Information

List of Models

EUN Series

Phase  Applicable load Level indicator         Base-up function    Soft-start time Carry               Rated voltage  Model
Single                                               (See note.)                               current
        Resistive load Yes                                                                              100/110 VAC    G3PX-220EUN
        Heater                                 Yes                Approx. 0.5 to 10 s 20 A              200/220 VAC    G3PX-240EUN
        (e.g., alloy heater                                                                                            G3PX-260EUN
        or halogen lamp)                                                                     40 A
        (See note 2.)
                                                                                             60 A

Note: 1. The base-up output with a 0-mA temperature controller output (i.e. the temperature controller is OFF) differs from that with a 4-mA
            temperature controller output. Refer the Base-up Characteristics on page 7.

        2. Contact your OMRON representative for applications to transformer loads.

EH Series

Phase  Applicable load       Level indicator     Single heater     Multiple heater     Carry           Rated voltage      Model
Single                       Yes                   open circuit       open circuit    current                          (See note 1.)
        Resistive load                                                  detection    20 A
        Heater                                       detection                       40 A               100/110 VAC    G3PX-220EH-CT03
        (e.g., alloy heater                                       No                 60 A               200/220 VAC    G3PX-220EH-CT10
        or halogen lamp)                       Yes                                   20 A                              G3PX-240EH-CT03
        (See note 3.)                                             Yes                40 A                              G3PX-240EH-CT10
                                                                                     60 A                              G3PX-260EH-CT03
                                               Yes (See note 2.)                                                       G3PX-260EH-CT10
                                                                                                                       G3PX-220EHN-CT03
                                                                                                                       G3PX-220EHN-CT10
                                                                                                                       G3PX-240EHN-CT03
                                                                                                                       G3PX-240EHN-CT10
                                                                                                                       G3PX-260EHN-CT03
                                                                                                                       G3PX-260EHN-CT10

Note: 1. EH- and EHN-series models are provided with a CT incorporating 30- or 100-cm-long lead wires and Power Device Cartridge. When
            ordering, specify the length of the lead wires by adding a code to the model number as shown below.
            G3PX-2@0EH-CT03: CT with 30-cm-long lead wires
            G3PX-2@0EH-CT10: CT with 100-cm-long lead wires

        2. Adjusts the multiple heater open circuit detection sensitivity of EHN-series models. Enables single heater open circuit detection in control
            of a maximum of five heaters.

        3. Contact your OMRON representative for applications to transformer loads.

EC Series

Phase     Applicable Level indicator           Constant-current     Single heater    Carry Rated voltage                 Model
Single         load                                   function        open circuit   current                           (See note.)

        Resistive load Yes                     Yes                      detection    20 A               100/110 VAC    G3PX-220EC-CT03
        Heater                                                                       40 A               200/220 VAC    G3PX-220EC-CT10
        (e.g., alloy heat-                                        Yes                60 A                              G3PX-240EC-CT03
        er, pure metal                                                                                                 G3PX-240EC-CT10
        heater, or halo-                                                                                               G3PX-260EC-CT03
        gen lamp)                                                                                                      G3PX-260EC-CT10
        (See note 3.)

Note: 1. EC-series models are provided with a CT Unit with lead wires (30- or 100- cm in length). When ordering, specify the length of the lead
            wires by adding a code to the model number as shown below.
            G3PX-2@0EC-CT03: CT with 30-cm-long lead wires
            G3PX-2@0EC-CT10: CT with 100-cm-long lead wires

        2. A CT Unit and Power Device Cartridge are provided with the Power Controller.

        3. Contact your OMRON representative for applications to transformer loads.

                                                                                                                                                         3
                                                                                                       G3PX

Accessories (Order Separately)

CT Unit                     Length of lead wires       Solderless terminals         Applicable models               Model
                        30 cm                      Yes                          G3PX-2@@EH             G32X-CT03
               Name     100 cm                                                                         G32X-CT10
CT Unit                 30 cm                                                   G3PX-2@@EHN            G32X-CT03HN
                        100 cm                                                                         G32X-CT10HN
                        30 cm                                                   G3PX-2@@EC             G32X-CT03C
                        100 cm                                                                         G32X-CT10C

Power Device Cartridge

              Name              Carry current         Applicable models                Model
Power Device Cartridge  20 A                       G3PX-220E@@             G32X-A20
                        40 A                       G3PX-240E@@             G32X-A40
                        60 A                       G3PX-260E@@             G32X-A60

Note: The G32X-A is a dedicated Power Device Cartridge for the G3PX.
        Refer to Replacement Parts on page 15.

Specifications

Ratings (at an Ambient Temperature of 25C)

Control

            Item              G3PX-                G3PX-                                  G3PX-        G3PX-
                             220EUN/               220EH/                                220EHN/       220EC/
                             240EUN/               240EH/                                240EHN/       240EC/
                             260EUN                260EH                                 260EHN        260EC

Rated voltage           100/110, 200/230 VAC

Frequency               50/60 Hz (See note 1.)

Input       External main 2 k (type B, 2 W min.)   3 k (type B, 2 W min.)    2 k (type B, 2 W min.)
signal for  setting
control     (See note 2.)

            Current input 4 to 20 mA (at 1 to 5 VDC) (Input impedance: 250) (See note 3.)

            Voltage ON/ 5 to 24 VDC (Input impedance: approx. 20 k)
            OFF input

            External duty 3 k (type B)
            setting

Relay output for alarm  ---                        SPDT: 8 A at 250 VAC/30 VDC

Note: 1. 50/60 Hz (no selector required) (EUN Series)
            Terminals 18 and 19 of EHN/EC-series models must be open when the supply frequency is 50 Hz. These terminals must be short-
            circuited when the supply frequency is 60 Hz.

        2. Use the G32X-V2K 2-k Variable Resistor for external main setting on EUN, EC, and EHN (G32X-V3K 3-k for EN-series models).

        3. Input 4 to 20 mA or 1 to 5 VDC linear input to the 4 to 20 mA current input terminal.

Output

            Model                                                       Applicable load

G3PX-220E@                   Rated load voltage    Load current                 Inrush current              Number of phases
G3PX-220E@N                                                                                            Single
G3PX-240E@              100/110, 200/220 VAC (50/  1 to 20 A (at 40C)       220 A (60 Hz, 1 cycle)
G3PX-240E@N             60 Hz)                     (See note.)
G3PX-260E@
G3PX-260E@N                                        1 to 40 A (at 40C)       440 A (60 Hz, 1 cycle)
                                                   (See note.)

                                                   1 to 60 A (at 40C)       440 A (60 Hz, 1 cycle)
                                                   (See note.)

Note: The G3PX-2@@EHN (model with multiple heater open circuit detecting function) and G3PX-2@@EC (constant-current model) require 20%
        min. of the rated current to detect a short mode failure. EC-series models detect an open mode failure if the load current has dropped to
        80% of the rated value. A short mode failure will be detected if the current has risen to 20% of the rated value.

                                                                                                                                                   4
                                                                                           G3PX

Characteristics

EU/EH Series

        Item                       G3PX-220EUN/                    G3PX-220EH/240EH/260EH               G3PX-220EHN/
                                  240EUN/260EUN                                                        240EHN/260EHN

Operating voltage range  10%                                                              0% to 100%
                                                                                           0% to 100%
Operating frequency range 1 Hz                                                            Approx. 0.5 to 10 s
                                                                                           (See note 3.)
Output voltage adjustable 0% to 95%                                                        20% max. (See note 4.)
range
                                                                                           Approx. 1/6
Internal duty setting range 0% to 100%                   10% to 100% (See note 1.)         30% max. of rated current
                                                                                           (See note 5.)
External duty setting range 0% to 100%                   10% to 100% (See note 1.)         1 s max.

Start-up time            Approx. 0.5 to 10 s             Approx. 0.1 to 1 s                G3PX-220EHN: approx. 1.2 kg
(See note 2.)            (See note 3.)                   (See note 3.)                     G3PX-240EHN: approx. 1.5 kg
                                                                                           G3PX-260EHN: approx. 1.8 kg
Base-up range            0% to 90%                       ---

Multiple heater open circuit ---
detection

Min. phase detection     ---                             Approx. 1/6

Min. phase setting       ---                             ---

Min. load current for ON er- ---                         1A

ror detecting

Abnormality detection time ---                           0.1 s max.

Voltage drop with output ON 1.6 V max. (RMS)

Leakage current          10 mA max. at 100/110 VAC, 20 mA max. at 200/220 VAC

Insulation resistance    100 M min. (at 500 VDC)

Dielectric strength      2,000 VAC, 50/60 Hz for 1 min.

Vibration resistance     Malfunction: 10 to 55 to 10 Hz, 100 m/s2

Shock resistance         Malfunction: 300 m/s2

Ambient temperature      Operating: 25C to 65C (with no icing or condensation)
                         Storage: 10C to 55C (with no icing or condensation)

Ambient humidity         Operating: 45% to 85%

Weight                   G3PX-220EUN: approx. 1.1 kg     G3PX-220EH: approx. 1.1 kg
                         G3PX-240EUN: approx. 1.4 kg     G3PX-240EH: approx. 1.4 kg
                         G3PX-260EUN: approx. 1.7 kg     G3PX-260EH: approx. 1.7 kg

Note: 1. Duty setting does not complete to the OFF state (i.e. 10% remains).
        2. The start-up time is factory-set to 1 s on the EH Series, approx. 0.5 s on the EHN and EC Series.
        3. This is the initial start-up time with a 100% duty setting.
        4. Detection is effective when the set current is reduced by 20% or more.
        5. The minimum set value in the G3PX-220EHN is 6 A. If a lower value is required, increase the number of wiring turns around the CT.

                                                                                                                                              5
EC Series                                                                                                     G3PX

                     Item                      G3PX-220EC                  G3PX-240EC                       G3PX-260EC
Operating voltage range          10%
Operating frequency range        1 Hz                                                         Peak current of 330 A within
Output voltage adjustable range  0% to 95%                                                     1 cycle
Internal duty setting range      0% to 100%
External duty setting range      0% to 100%
Start-up time                    Approx. 0.5 to 10 s
Min. load current for ON error   20% max. of rated current
detecting
Current limit range              0% to 100%
Excess current detection
                                 Peak current of 110 A within    Peak current of 220 A within
Constant current                 1 cycle                         1 cycle

Abnormality detection time       3% max. with 10-time increment of load value
Voltage drop with output ON      3% max. with 10% change of voltage
Leakage current
Insulation resistance            1 s max.
Dielectric strength
Vibration resistance             1.6 V max. (RMS)
Shock resistance
Ambient temperature              10 mA max. at 100/110 VAC, 20 mA max. at 200/220 VAC

Ambient humidity                 100 M min. (at 500 VDC)
Weight
                                 2,000 VAC, 50/60 Hz for 1 min.

                                 Malfunction: 10 to 55 to 10 Hz, 100 m/s2

                                 Malfunction: 300 m/s2

                                 Operating: 25C to 65C (with no icing or condensation)
                                 Storage: 10C to 55C (with no icing or condensation)

                                 Operating: 45% to 85%

                                 G3PX-220EC: approx. 1.1 kg
                                 G3PX-240EC: approx. 1.4 kg
                                 G3PX-260EC: approx. 1.7 kg

                                                                                                                             6
Engineering Data                                                                                         G3PX

The following data is for an ambient temperature of 25C.                       Duty Setting

Output Characteristics                                                          G3PX-EUN/EH/EHN Models

G3PX-EUN/EH/EHN Models                  G3PX-EC Models                                                                                      100%
                                                                                                                                               60%
Output voltage (%)                      Output voltage (%)                      Output voltage (%)
                                                                                                                                            40%
                                                                                                                                               20%

                  Input current (mA)                        Input current (mA)                      Input current (mA)

Base-up Characteristics

    G3PX-2@0EUN Models

Output voltage (%)

                    Input current (mA)

                                                                                                                                                    7
                                                                                                                                                                                                                  G3PX

Load Current vs. Ambient Temperature

G3PX-220E@ Models                                                               G3PX-240E@ Models                                                                 G3PX-260E@ Models

                         25                                                     Load current (A)         50                                                              80
Load current (A)                                                                                                                                                  Load current (A)
                         20                                                                              40

                                                                                                                                                                                           60

                         15                                                                              30                                                                                47
                         14

                                                                                                                                                                                           40

                         10                                                                              20

                                                                                                                                                                                           20

                         5                                                                               10

                         0         20       40              55 60                                        0-10 0  20         40        55 60                                                0       20         40         55 60
                          -10 0                                                                                                                                                             -10 0

                                   Ambient temperature (C)                                                      Ambient temperature (C)                                                          Ambient temperature (C)

                         25                                                                              50                                                                                80
                                       Derating curve under UL standard                                                  Derating curve under UL standard                                                Derating curve under UL standard

                         20                                                                              40                                                                                60

Load current (A)         15                                                     Load current (A)         30                                                       Load current (A)         47
                         14                                                                              25                                                                                40
                                                                                                         20
                         12                                                                                                                                                                25
                         10                                                                              10                                                                                20

                         5

                         0         20 25    40 55 60                                                     0       20 25  40      55 60                                                      0       20 25 40 55 60
                         -10 0                                                                           -10 0                                                                             -10 0

                                   Ambient temperature (C)                                                   Ambient temperature (C)                                                          Ambient temperature (C)

Note: Please use proper ventilation and                                         Note: Please use proper ventilation and                                           Note: 1. Please use proper ventilation and
        cooling.                                                                        cooling.                                                                              cooling.

                                                                                                                                                                          2. Please note that derating curve
                                                                                                                                                                              above 40 A is applicable under the
                                                                                                                                                                              UL standard only with forced air
                                                                                                                                                                              cooling by fan.

One Cycle Surge Current: Non-repetitive

                         G3PX-220E@ Models                                                               G3PX-240E@ Models                                                                 G3PX-260E@ Models

Inrush current (A.Peak)  200                                                    Inrush current (A.Peak)  400                                                      Inrush current (A.Peak)  400

                         150                                                                             300                                                                               300

                         100                                                                             200                                                                               200

                         50                                                                              100                                                                               100

                             0 10  30 50 100 200 500 1,000               5,000                           0                                                 5,000                           0                                               5,000
                                                                                                          10 30 50 100 200 500 1,000                                                         10 30 50 100 200 500 1,000

                                          Energized time (ms)                                                           Energized time (ms)                                                            Energized time (ms)

                         Note: The above are possible on condition that the G3PX is in non-repetitive operation. If the G3PX is in repetitive operation,
                                 reduce the applied current to half.

                                                                                                                                                                                                                                                  8
                                                                                                                            G3PX

Nomenclature                                                        Multiple Heater Open Circuit
                                                                    Detection (EHN-series Model)
Single-function Model
(EUN-series Model)                                                  G3PX-2@0EHN-CT@@
                                                                                                         RUN/SET switch for setting condition for
G3PX-2@0EUN                                                                                             multiple heater open circuit detection.

                                  Level indicator                                        Level indicator      RESET switch
                                                                    POWER indicator
  POWER indicator
  BASE-UP adjuster                                                  SHORT indicator
                                                                    (for short-mode
  DUTY adjuster                                                     failure detection)
  (for internal
  slope setting)                                      Power Device          CT Unit
  TIME adjuster                                       Cartridge     OPEN indicator
  (for Extended                                                     (for multiple heater
  soft-start time)                                                  open circuit detection)

Single Heater Open Circuit                                          ALARM adjuster
Detection (EH-series Model)                                         (for multiple heater
                                                                    open circuit detection)
G3PX-2@0EH-CT@@
                                     Level indicator                DUTY adjuster            Power Device
                                                                    (for internal slope      Cartridge
               POWER indicator                                      setting)
      SHORT indicator
      (for short-mode                                                     TIME adjuster
      failure detection)                                                  (for extended
                                                                          soft-start time)
             CT Unit
      OPEN indicator                                                Constant-current Model
      (for single heater                                            (EC-series Model)
      open circuit
      detection)                                                    G3PX-2@0EC-CT@@

        DUTY adjuster                                                                        Level indicator
        (for internal
        slope setting)                                                POWER indicator                         RESET
         TIME adjuster                                                                                        switch
         (for soft-start                                   SHORT indicator
         time)                                             (for short-mode                                    Power
                                                           failure detection)                                 Device
                                                                                                              Cartridge
                                                      OPEN indicator (for single
                                                      heater open circuit
                                                      detection)

                                                      Reset               CT Unit
                                                      switch
                                                              CURRENT limit adjuster
                                                              (for limiting current)

                                                      Power         DUTY adjuster
                                                      Device        (for internal slope
                                                      Cartridge     setting)

                                                                    TIME adjuster
                                                                    (for extended

                                                                    soft-start time)

                                                                                                                                                   9
Operation                                                                                                    G3PX

Error Detecting Function                                               2. When EH/EHN/EC-series models detect a short-mode failure, the
                                                                            SHORT indicator is lit and the SPDT relay output is ON.
Wiring                                                                                       With continuous load current.

Single-phase Models                                                                          With load current shut off.

All G3PX-2@0EH/EHN/EC-series models incorporate terminals 11            Note: When the G3PX detects a short-mode failure, all LEDs of the
and 12 for the CT Unit, 13 and 14 for the external reset switch, and            Level indicator and red SHORT indicator are lit. When you use
16 and 17 for relay output as well as power/input terminals 1 through           a breaker to disconnect the load with the relay output, all LEDs
10.                                                                             of the Level indicator will be OFF regardless of the input to the
                                                                                G3PX.
                      CT Unit
                      G32X-CT@@ (see note 1)                            3. When EC-series models detect an overcurrent, the Level indicator
                                                                            will flash and the SPDT relay output is ON. The input signal will
                                           CT Unit                          be shut off.

                      11                   Load 1                       Note: When resetting, leave power supply terminals 10 to 9 or 8 ON.

                      12

External reset        13

switch

                      14                   G3PX-2@0EH

(see note 2)

                      15

        Relay output  16
        (SPDT)

                                       17  Load 2

        (see note 3)
                         Load
                         Load

Note: 1. Connect either the black or white lead wire of the CT
               Unit to terminal 11 and the other lead wire to terminal
               12. The G3PX will malfunction if you do not connect
               the CT Unit to the G3PX.

          2. The rated current and voltage of G3PX models when
               reset are as follows:
               EH-series models: 12 mA at 12 VDC
               EHN- and EC-series models: 1 mA at 12 VDC

          3. For more than one heater.

Output

Single-phase Models

The following illustrations show the condition of the G3PX LED
indicators when the G3PX detects heater open circuit, a short-mode
failure (ON failure of components), or overcurrent (EC-series
constant-current models only). The indicator and relay output signals
are reset with the internal or external reset switch provided that the
error condition has been remedied.

1. When EH/EHN/EC-series models detect single or multiple heater
    open circuit, the OPEN indicator is lit and the SPDT relay output
    is ON.

Note: When the G3PX detects heater open circuit, the Level indicator
        will be OFF regardless of the G3PX input condition. The red
        OPEN indicator will be lit. EHN-series models, however, will
        continue operating with level indication.

                                                                                                                                                   10
                                                                                                                             G3PX

Wiring

Main Circuit

Single-phase Models

The following illustrations show connection examples:

1                              Load 1

2

3

4

5
             G3PX

6

                            7
200/230 VAC

                            8
100/110 VAC

                            9

10                             Load 2

                          Load

Note: Use a single power supply for the G3PX and the load.

Setting Circuit

Analog Control

Single-phase Models

1. A Temperature Controller with an output of 4 to 20 mA is used to control the G3PX.

                                                              1   Load 1                         +  4 to 20 mA  4
                                                                  G3PX            Temperature                        G3PX
                                                              2   Load 2          Controller -
                                                                                                                5
                                                              3                      (600 *)
                                                                                                                (250 *)

                                                + 4 to 20 mA  4
                               Temperature

                               Controller -                   5

                                                              6                                                   4
                                                                                                                       G3PX
                                                              7
                                                                                                                  5
                                                              8                                                   (250 *)

                                                                                                                *Impedance

                                                              9

                                                              10

                                Note: Two G3PX models can be connected in series to OMRON's single Temperature
                                         Controller (with an internal impedance of 600 ) with a current output.

2. A Temperature Controller with an output of 4 to 20 mA is used with the G3PX to change the duty.

                                                                  1       Load 1
                                                                          G3PX
                                                                  2       Load 2

                                                                  3                    Internal DUTY
                                                                                       adjuster
                                                +  4 to 20 mA     4
                                                                                             DUTY
                               Temperature

                               Controller -                       5

                                                                  6

                                                                  7

                                             3                    8

                                             2                    9

                                             1                    10

                               G32X-V3K External Variable
                               Resistor (3 k) for duty setting

                               Note: You can change the duty with the external or internal ramp adjuster.

                                                                                                                             11
                                                                                                                       G3PX

ON/OFF Control

Single-phase Models

1. A Temperature Controller is used to change the duty of G3PX.

                                                        1        Load 1
                                                                 G3PX
                                          5/12/24 VDC 2          Load 2

                                 + ON/OFF               3                              Internal DUTY
                                                                                       adjuster
                    Temperature                         4
                    Controller                                                               DUTY

                                 -                      5

                                                        6

                                                        7

                    3                                   8

                    2                                   9

                    1                                   10

                    G32X-V3K External
                    DUTY Adjuster (3 k)

                    Note: You can change the duty with the external or internal variable resistor.

2. A Temperature Controller (with a voltage output) is used to control several G3PXs.

   Temperature Controller specifications      No. of G3PX
E5@K: 40 mA at 12 V                       20 sets
E5@N: 20 mA at 12 V                       20 sets
20 mA at 5 V                              20 sets
10 mA at 5 V                              20 sets

Connection Example

                    Temperature
                    controller

                         +-

                                          3                      3                           3
                                               G3PX                   G3PX                        G3PX

                                          5                      5                           5

3. A Temperature Controller (with a relay output) is used to vary the duty of G3PX.

                                          Temperature
                                          controller

                                                                                    Load 1
                                                                         1

                                                                         2

                                                                         3                              Internal DUTY
                                                                                                        adjuster
                                                                         4
                                                                                                             DUTY
                                                     3                   5
                                                                                     G3PX
                    G32X-V3K External                2
                    DUTY Adjuster (3 k)                                  6

                                                     1                   7

                                                                         8

                                                                         9

                                                                         10          Load 2

                                                                                                                             12
                                                                                  G3PX

Manual Control

Single-phase Models

                         3                                   1   Load 1

G32X-V3K or G32X-V2K     2                                   2

External DUTY Adjuster                                       3                        Internal DUTY
                                               1                                      adjuster

                                                             4                               DUTY

                         3                                   5                    Note: Delicate duty adjustment is possible with the external or
                                                                          G3PX            internal resistor. Use a right DUTY adjuster (2- or 3-k
G32X-V3K External DUTY   2                                                                type) according to the G3PX model as follows:
                                                             6                            G32K-V3K (3 k) for EH-series models
Adjuster (3 k) for duty                                                                   G32X-V2K (2 k) for EUN-, EHN-, and EC-series models

setting                  1                                   7

                                                             8

                                                             9

                                                             10  Load 2

Two-position Control

Single-phase Models                                                       Load 1
                                                             1
                                               H (High)
                                                             2
G32X-V3K or G32X-V2K
External DUTY Adjuster

                                                             3

                                                             4

                         L (Low)                         RY

                                                             5
                                                                          G3PX

                                                             6

                                                             7

                                                             8

                                                             9

                                                             10  Load 2

                                                         Note: 1. A temperature controller with relay output or a single relay can be used with the G3PX
                                                                       in two-position (high-and low-position) control, in which case the relay contact current is
                                                                       30 mA at 12 VDC with the External DUTY Adjuster set to 0 .

                                                                   2. Use a right DUTY adjuster (2- or 3-k type) according to the G3PX model as follows:
                                                                       G32X-V3K (3 kW) for EH-series models
                                                                       G32X-V21K (2 kW) for EUN-, EHN-, and EC-series models.

Setting of Base-up Output (G3PX-2@0EUN Series)

The base-up output can be adjusted with the base-up adjuster knob. It is also possible to control the base-up output for the full scale of 4 to
20-mA input current by adjusting the duty adjuster. Refer to Engineering Data on page 7 for the base-up characteristics.

G3PX-2@0EHN Series (Multiple Heater Open Circuit Detection Model)

Setting                                                                           3. Adjust the sensitivity.
                                                                                      Turn the ALARM adjuster and set to the position where the OPEN
1. Use the G32X-CT@@HN CT Unit and make sure that the G3PX is                         indicator is lit. Stop turning the ALARM adjuster as soon as the
    wired correctly.                                                                  indicator is lit to complete the setting.

2. The G3PX initially set is shown in the following illustration.
    Make sure that the RUN/SET switch has been set to SET.
    Make sure that the DUTY adjuster has been turned clockwise to
    the maximum.

                                                                                                                                                                    13
                                                                          G3PX

4. Set the RUN/SET switch to RUN.
    When all settings have been finished, the OPEN indicator is OFF.

Note: 1. The G3PX can control any part of the phase as long as the
            controlled phase is approximately 1/6 or more in width.

        2. Be sure to prepare terminals 18 and 19 corresponding to
            the supply frequency of 50 Hz or 60 Hz. Otherwise, a setting
            error will result in a malfunction regardless of the RUN/SET
            switch setting.
            When the error has occurred, turn the ALARM adjuster
            counterclockwise to the minimum setting, reset the G3PX,
            and readjust.

                                                                                14
                                                                                          G3PX

Replacement Parts

G32X-A Power Device Cartridge

The temperature indicator will be lit in red if the power element is damaged. If the power element is damaged due to overcurrent or other reasons,
the power element and its peripheral parts can be replaced.
The power element and its peripheral parts can be replaced without disconnecting the wires of the G3PX.
Improve the heat radiation of the G3PX before replacing the Cartridge.
The temperature indicator will not be lit in red if the G3PX has overcurrent due to load short-circuiting or other reasons over a short time.

Appearance

              G32X-A20                                        G32X-A40  G32X-A60

Replacement of G32X-A20 Power                                           3. Insert the Cartridge into the opening of the G3PX so that the
Device Cartridge                                                            letters on the Cartridge and those on the G3PX are in the same
                                                                            direction and sides A and B are even.
Use the special tool (provided) to extract the Cartridge for
replacement with a new one.                                                                               A
                                                                                                B
Extraction
                                                                        4. Attach the terminal cover.
Follow the procedures below to dismount the Power Device                5. Switch on the power and check the G3PX to be sure it works
Cartridge from the G3PX.
1. Switch off the power.                                                    properly.

2. Remove the terminal cover.                                           G32X-A40/60

3. Hook the tool on the indented portions of the Power Device           The G32X-A40 and G32X-A60 are secured with screws.
    Cartridge as shown in the illustration below and pull up the Power
    Device Cartridge vertically.                                        Extraction

Special tool        Terminal cover                                      The procedures for dismounting the Power Device Cartridge are as
                                                                        follows:
  Indented                                                              1. Switch off the G3PX.
  portions                                                              2. Remove the terminal cover.
                                                                        3. Be sure to turn off the G3PX and loosen the screws located in the
Mounting
                                                                            upper center and lower center. These screws are connected to
The procedures for mounting the Power Device Cartridge are as               terminals 1 and 2.
follows:
                                                                                            Loosen
1. Apply silicone grease (provided with the G32X-A) to the entire
    surface of the heat sink.

2. Make sure there is no dust or pieces of wire on the heat sinks of
    the G32X-A or the G3PX.

                                                                                  Loosen

                                                                                          15
4. Loosen the screws on both corners.                                                                                        G3PX

                                                             Loosen                     3. Insert the Cartridge into the opening of the G3PX so that the
                                                                                            letters on the Cartridge and those on the G3PX are in the same
                      Loosen                                                                direction and sides A and B are even.

                                                                                                                     A

                                                                                                            B

5. Hold the indented part of both corners to dismount the Cartridge.                    4. Tighten the screws on both corners with a tightening torque of
                                                                                            0.59 to 0.78 Nm.
Mounting
                                                                                        5. Tighten the center screws of the G3PX with a tightening torque of
1. Apply silicone grease (provided with the G32X-A) to the entire                           0.59 to 0.78 Nm.
    surface of the heat sink.
                                                                                        6. Attach the terminal cover.
2. Make sure there is no dust or pieces of wire on the heat sinks of
    the G32X-A or the G3PX.                                                             7. Switch on the power and check the G3PX to be sure it works
                                                                                            properly.

External Variable Resistor

The G32X-V3K and G32X-V2K are provided with a set consisting of                         Note: 1. The G32X-V3K is equivalent to the conventional G32X-VR.
adjuster, knob, and nameplate.                                                                  2. Resistive Value

           Resistive value                                           Model                                                                    The resistance is
            (See note 1.)                                                                                                                     read on the back of
                                                    G32X-V3K (See note 2.)                                                                    the variable resistor.
3 k                                                 G32X-V2K
2 k

External DUTY Adjuster                                                      Knob

               2.51                                         2.80.2 dia.                     34

                                  M9P0.75                                                     26

                                  6  0     dia.                            Filled with
                                     -0.1                                  white resin
                                                             120.2

311 dia.

                                     10.1
                                      R26 max.

           15 min. 101                    1.60.2  30 max.

                                                                                        13.4

               17 max. 201

Mounting Holes                                          Nameplate                                                 14 17
                                                                                                            6.5
                     3 dia. hole                          %                                       1.6

                      120.2                        48

9.5 dia. hole                                                G32X-VR 100
                                                                  48

                                                                                                                                                                      16
                                                                                                                                                         G3PX

Dimensions                                                                                                     Mounting Holes

Note: All units are in millimeters unless otherwise indicated.

Single-phase Models

G3PX-220E@ Series

                                                                                                                                         Four, 4.5 dia.
                                                                                                                                         or M4 holes

                                                                         119                                   1400.3

                                                                                                                             500.3

                                                                         Two, 4.6 dia.                                  8.6  Two, M4 screws
                                                                         holes
                                                                                                                             8.6

                                                                                                          7.6                109.8

                                                  1400.2
                                          150 max. 130

                                                                         Two, R2.3
                                                                         holes

                                 108                             500.2
                                   120                          70 max.

                                130 max.                                                                       Mounting Holes            Four, 4.5 dia.
                                                                                                                                         or M4 holes
G3PX-240E@ Series

                                                                         119                                   1400.3

                                                                         Two, 4.6 dia.                                   650.3
                                                                         holes                                 13 Two, M5 screws

                                                                                                         7.6                  13
                                                    1400.2
                                                                                                                                  109.8
                                          150 max. 130

                                                                         Two, R2.3
                                                                         holes

108                                        650.2
  120                                     85 max.

130 max.

                                                                                                                                                         17
                                                                                                                                 G3PX

G3PX-260E@ Series                                                                     Mounting Holes

                                                                                                                  Four 4.5-dia.
                                                                                                                  or M4 holes

                                                       114
                                                                             1400.3

                                                   Two, 4.6 dia.                             800.3
                                                   holes                              17 Two, M6 screws

                                                         7.6                                              17

                          1400.2                                                                          109.8
                   150 max. 130

                                                   Two,
                                                   R2.3
                                                   holes

108                                        800.2
                                         100 max.
  120
130 max.

G32X-CT03@ Series                        60 max.
G32X-CT10@ Series                            50

                                                   17                                 Mounting Holes

                                         40                                 14         Two 4.5-dia. or M4 holes
                                                   17 dia. hole
                                                                                           500.2
                                                   (15 dia., see

                                                   note 1)

                                                                                  55
                                                              35
                                                         24
                                                   9.5

                   30
                           (see note 2)

Note: 1. Color of the hole
               EH Series: Black
               EHN Series: White
               EC Series: Light gray
               The size of the hole of CT Units for EC- and EHN-series models is 15 dia.

          2. The G32X-CT03@ incorporates 30-cm solderless terminals and the G32X-CT10@
              incorporates 100-cm solderless terminals.

                                                                                                                                       18
                                                                                                                                                                    G3PX

Installation

Terminal Arrangement

Single-phase Models

G3PX-220EUN                                                                        G3PX-220EH
G3PX-240EUN                                                                        G3PX-240EH
G3PX-260EUN                                                                        G3PX-260EH

1                  External main setting 2 kB, 2 W for                             CT UNIT                          1   External main setting
                                                                                   G32X-CT
                   3 kB 2 W               EUN-series models                                                             3 kB 2 W
                                                                                                    W
2                  MAN SET                                                                                   11     2   MAN SET

            Voltage ON/OFF input                                                                     B                  Voltage ON/OFF input
                                                                                                             12
            VOLTAGE IN                                                                                                       VOLTAGE IN
3                                                                                                                   3

    Current input                                                                                             13         Current input 4 to 20 mA
                                                                                   RESET
   4 to 20 mA DC CURRENT            5 to 24 VDC                                                                          DC CURRENT                    5 to 24 VDC
4                                   INPUT                                                                     14    4                                  INPUT

                (1 to 5 VDC)                                                                                                         (1 to 5 VDC)
                (Voltage)
5                                                                                                                                    (VOLTAGE)
                                                                                                                    5

                                                                                               15

6                  External duty setting                                                                            6   External duty setting 3 kB

                   3 kB                                                            ALARM       16                       MAN DUTY SET

                   MAN DUTY SET

7                                                                                                                   7

                           SOURCE                                                                               17                             SOURCE
8                                                                                  Internal contact                 8
                                                                                   configuration

9                                   200/230 VAC                                                                     9                                  200/230 VAC
                                    50/60 Hz                                                                                                           50/60 Hz
               100/110 VAC                                                                                              100/110 VAC

10             50/60 Hz                                                                                             10  50/60 Hz

G3PX-220EHN/220EC
G3PX-240EHN/240EC
G3PX-260EHN/260EC

CT UNIT                         1                 External main setting
G32X-CT
                                                  2 kB 2 W
                 W
                          11    2                 MAN SET

                  B                 Voltage ON/OFF input
                          12
                                      VOLTAGE IN
                                3

                          13        Current input 4 to 20 mA
RESET
                                4   DC CURRENT
                          14
                                          (1 to 5 VDC)                5 to 24 VDC

                                          (VOLTAGE)                   INPUT

                                5

                            15  6                 External duty setting
ALARM

                   16                             3 kB

Internal                                          MAN DUTY SET

contact                         7

configuration      17                                         SOURCE
                                8

OPEN 50 Hz         18

SHORT 60 Hz                     9                                     200/230 VAC
                                                                      50/60 Hz
(see note)         19                     100/110 VAC

                                10        50/60 Hz

Note: Open the terminals for 50 Hz or short-circuit the terminals for 60 Hz. When the product is shipped, the terminals are short-circuited using a
        short-circuiting bar to set to 60 Hz. When using at 50 Hz, remove the short-circuiting bar.

                                                                                                                                                                    19
                                                                                                                          G3PX

Safety Precautions                                                   Wiring

Precautions for Correct Use                                         Make sure that the lead wires are thick enough according to the
                                                                     current.
Please observe the following precautions to prevent failure to
operate, malfunction, or undesirable effect on product performance.  Be sure to turn off power to the G3PX when wiring. The G3PX has
                                                                     current leakage although the G3PX is turned off if the power supply
Load                                                                 is connected to the G3PX, which may give an electric shock.

Only resistive loads can be connected to the G3PX. Contact your      Do not wire power lines or high-tension lines along with the lines of
OMRON representatives if it is necessary to connect inductive or     the G3PX in the same conduit, otherwise the G3PX may be
transformer loads.                                                   damaged or malfunction due to induction. Be sure to wire the lines of
                                                                     the G3PX separated from power lines or high-tension lines or laid in
Mounting                                                             an exclusive, shielded conduit.

Pay utmost attention when mounting the G3PX so that the G3PX will    Tightening Torque
not fall thus resulting in injury.
                                                                     Apply the following tightening torque.
Vertical Mounting                                                    Output terminal:
                                                                     20-A model: 1.47 Nm
                                                                     40-A model: 2.45 Nm
                                                                     60-A model: 4.12 Nm
                                                                     Terminal block:
                                                                     Single-phase model: 0.98 Nm
                                                                     Be sure to protect the terminals with the protective cover after wiring.

                                                                     Wiring for Error Detection

                                                                     If a contactor is employed and operated with the relay output signal
                                                                     of the G3PX for error detection, make sure that the G3PX is closer to
                                                                     the power supply than the contactor.

Horizontal Mounting

                                                                     Instruments

                                                                                     Instrument                      Remarks

                                                                     Thermal type                              Available

                                                                     Digital type displaying root-mean-square
                                                                     values

                                                                     Moving-iron type

Note: In the case of flat mounting, the 30%                          Rectifier type                            Not available (not precise
        derating of the load current is required.                    Multimeter                                enough)

                                                                     Digital multimeter

Close Mounting Example (Single-phase Models)

                     10 mm     10 mm                                 The instruments are used for displaying root-mean-square voltage
                                                                     and current values of the AC circuitry.

                                                                     Operation Monitoring

                                                                     The level indicator just indicates the phase of the load and it is not
                                                                     highly precise.

                                                                     Ramp Setting

                                                   50 mm

                                                                     There is a decrease in ramp if the internal DUTY adjuster is turned
                                                                     counterclockwise.

                                                                                         DUTY                  DUTY

                                                                                         100%                  10%

                     10 mm     10 mm                                 If the External DUTY Adjuster is used, set the Internal DUTY
                                                                     Adjuster to 100%.
Note: Make sure that there is a space of at least 50 mm
        vertically and at least 10 mm horizontally between

adjacent single-phase models.

                                                                                                                                               20
CT Unit                                                                                                                          G3PX

The CT Unit varies with the G3PX-series model. Use the following                            Troubleshooting
CT Units in combination with the G3PX models.
G3PX-2@0EH Series: G32X-CT@@                                                                Check the following if the G3PX does not operate or has difficulty in
G3PX-2@0EHN Series: G32X-CT@@HN                                                             temperature control.
G3PX-2@0EC Series: G32X-CT@@C                                                                The load does not turn on with 100% input.
If any of the following models is used and the actual load current is
50% of the maximum rated load current or lower, increase the                                  Check the default internal ramp setting.
number of turns of the wire around the CT Unit.
G3PX-20EHN Series (multi-heater open circuit detective models)                              DUTY          Make sure that the adjuster
G3PX-20EC Series (constant current)                                                                       is set to the farthest
For example, make two turns if the actual load current is 50% of the                                      clockwise position.
maximum rated load current and four turns if the actual load current
is 25% of the maximum rated load current.                                                   Also check the current limit adjuster if the G3PX is a constant DC
If the G3PX is a constant current model, do not increase the number                         model.
of turns of the wire around the CT Unit excessively, otherwise the
overcurrent detective function may operate by mistake.                                           CUR LIM

External DUTY Adjuster                                                                      The G3PX does not operate or is in abnormal operation.

Use the External DUTY Adjuster with a resistance of 2 k or that                               Make sure that all input terminals are connected properly with no
with a resistance of 3 k according to the G3PX-series model in use.                           mistakes in polarity.
Refer to the following combinations.
G3PX-2@EH Series: G32X-V3K (3 k)                                                              Make sure that the internal DUTY adjuster is not set to the farthest
G3PX-2@0EUN Series                                                                            clockwise position.
G3PX-2@0EC Series
                                                                                              Make sure that the frequency used by the G3PX (i.e., 50 or 60 Hz)
Base-up Function                                                                              is set properly. (This applies to the EC, and EHN models.)

If the model in use has the model number suffix "EUN," the base-up                           The G3PX malfunctions if the external adjusters are turned.
function is available.
The base-up output of the G3PX with a temperature controller output                           Make sure that the numbers on the external adjusters coincide with
of 0 mA (i.e., the temperature controller is turned off) and that of the                      the corresponding terminal numbers on the G3PX.
G3PX with a temperature controller output of 4 mA are different from
each other.                                                                                   Make sure that the 2-k and 3-k DUTY adjusters are connected
                                                                                              correctly.
Power Device Cartridge
                                                                                                          External main setting  External duty setting
Do not apply power to the G3PX with the Power Device Cartridge
dismounted.                                                                                               (Positive)                                  (Positive)

Heater Open Circuit Detection                                                                           Note: 1, 2, 3, 5, 6, and 7 are terminal numbers
                                                                                                                of the G3PX.
EH and EHN Models
                                                                                             Temperature control with a Voltage-output Temperature Controller
The heater open circuit detective function is not available for detect-                       is not smooth.
ing the phase less than the following.
                                                                                            Make sure that the controlled soft-start up/down time has been
                                                                      Phase not detectable  adjusted properly. If not, turn the TIME adjuster counterclockwise
                                                                                            to the minimum setting to reduce the controlled start-up/down time.
                                             G3PX-20EH Series: /8 or less
                                             G3PX-20EHN Series: Approx. /6 or less          Input signal                                                TIME

Power Supply                                                                                Controlled                           Reduce this period.
                                                                                            soft-start
Single-phase Models Only                                                                    up                                                          TIME

Do not apply 200 V to the 100-V terminals, otherwise the thermal                            Input signal
fuse of the built-in transformer will be blown and the G3PX will not
operate.                                                                                    Controlled
                                                                                            soft-start
Others                                                                                      up

It is not possible to use three single-phase models for three-phase
load control.
If three-phase power supply is used for single-phase models
operating in parallel, make sure that the two phases supplied to all
the single-phase models are the same.

                                                                                                                                                                  21
The Level indicator is not OFF with a 0% input signal (G3PX-                                              G3PX
  2@0EUN Series).
                                                                        The following wiring will be required if the breaker or contactor
  Make sure that the BASE UP adjuster has been turned counter-          connected between the power supply and the G3PX is operated by
  clockwise to the minimum setting.                                     the relay output of the G3PX.

BASE UP  Make sure that the
         adjuster is turned
         counterclockwise to the
         minimum setting.

The OPEN indicator of a multiple heater open circuit detection
  model is lit at the initial stage (G3PX-2@0EHN Series).

Make sure that the initial settings are OK. If not, readjust the        Magnet                                           Load
G3PX.                                                                   contactor
Make sure that terminals 18 and 19 are open if the supply
frequency is 50 Hz. These terminals must be short-circuited if the
supply frequency is 60 Hz.

Make sure that the load current is large enough.

The Level indicator LEDs of a constant-current model are all lit and
  no power control operation is possible.

Make sure that the load current is large enough.

Countermeasure 1: Adjust the CUR LIM adjuster so that the LED
on the farthest right of the Level indicator is OFF.

         Adjust so that this LED is OFF.

CUR LIM adjuster for limiting current

  Countermeasure 2: When the supply current is less than 50%,
  increase the number of turns. When the supply current is 50% of
  the rated current, the wires must be coiled twice on the CT Unit.
  When the supply current is 25% of the rated current, the wires
  must be coiled three to four times on the CT Unit.

No reset will be performed even if the RESET button is pressed.
  Check whether the RESET button is pressed while there is nothing
  input into to power supply terminals 8 and 10 or 9 and 10 of the
  G3PX.

  Be sure to press the RESET button with power supplied to the
  G3PX.

         ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
         To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                           In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                           22
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2008.11
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2008 All Right Reserved.