电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

FQ-D30

器件型号:FQ-D30
器件类别:热门应用    机电_工控_自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

Controllers Touch Finder, DC PS

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Controllers
RoHS:YES
商标:
Brand:
Omron Automation and Safety
产品类型:
Product Type:
Controllers
工厂包装数量:
Factory Pack Quantity:
1
子类别:
Subcategory:
Controllers
商标名:
Tradename:
Sysmac
零件号别名:
Part # Aliases:
FQD30

FQ-D30器件文档内容

CODE READER FQ-CR SERIES

Exceptional Reading Performance with Easy Operation

                                             Multi Code Reader

                                             FQ-CR1 Series

                                             2D Code Reader for Direct Part Marking codes

                                             FQ-CR2 Series

»  Read  from  everything  from  paper  and  labels to metal, PCBs, and glass              for  a  wide  range  of  applications.
2

   Solve a variety off different applications with one product series

   Read Codes Printed on Paper or Labels                                                                  Multi Code Reader     FQ-CR1 Series

   Paper or Cardboard                                                      Medical Packs

                                                 ITF (Interleaved 2 of 5)                                              QR Code  Codebar (NW-7)

   PET Bottles                                                             Medication Boxes

                                                 JAN/EAN/UPC                                                     Data Matrix    GS1-DataBar

   Reads 14 Different Codes                                                                                                     FQ-CR1

   Many different codes are used for different applications. And for some products, different codes  are  printed together.

   The FQ-CR1 can read many different codes without requiring any changes to its settings.

   Barcodes:           JAN/EAN/UPC                                         Code39                                          Codabar (NW-7)

   Reads 9             ITF (Interleaved 2 of 5)                            Code93                                          Code128 / GS1-128

   different codes.    GS1-DataBar                                         GS1-128 Composite Code                          Pharmacode

   2D codes:           Data Matrix                                         QR Code                                         Micro QR Code

   Reads 5             PDF417                                              Micro PDF417

   different codes.

                                                                                                          •  QR  code  is  the registered trademark  of  DENSO  WAVE.
                                                                                                                                                              3

There are many instances when different barcode or 2D code systems are used                    together    in the same manufacturing process.

Code printing quality can also vary due to imperfect printing or low contrast.

The FQ-CR Series handles these and many other conditions.

The FQ-CR Series can be easily introduced without using different code readers                 and

operating procedures for each of the different processes.

Reads Direct Part Marking (DPM) Codes                                                                      2D Code Reader for               FQ-CR2 Series

                                                                                                           Direct Part Marking (DPM) codes

DPM codes on Resin

                                Data Matrix

DPM codes on small parts                          DPM codes on metal                                       DPM codes on film or glass

                                Data Matrix                                     Data Matrix                                                  Data Matrix

Easily reads difficult codes                                                                                                                FQ-CR2

Just read the code and register it, and then let the following functions automatically tune the settings.

Depending on the conditions of the code, the automatic retry and code error correction functions let, essentially anyone, easily adjust the settings.

Filter function                                   Retry function                                           Code Error Correction

Three stages of filtering are automatically       You can retry the settings until reading is              Code omissions and errors are automatically

selected for the read image from Smooth, Dilate,  successful while automatically changing the              corrected when the code is read.

Erosion, and Median filtering.                    exposure time and other reading parameters.

Before Dilation                 After Dilation    Before Retry        After Retry                          Before Processing                After Processing
4

   FQ-CR2

   OMRON’s Unique Algorithm Provides

   Superior Reading Ability for Direct Part Marking codes

   Removal of Printing Irregularities or Noise

   Filter function

   You can apply up to three of the four unique filters developed by OMRON

   in the desired order to remove printing irregularities and noise, in order to  achieve a stable reading.

   Types of Filtering

           Smooth       Smooths the image.                                              Erosion                For white codes, reduces the cell size.

                                                                                                               Effective for reading separated dot codes.

           Dilate       For white codes, increases the cell size.                       Median                 Removes noise.

                        Effective for reading codes with cell spreading.

   Combining Filtering  Erosion and dilation can be combined to connect           dots  without changing  the  dot thickness.

                                            Dilate                                      Erosion
                                                                                                                                                                              5

                                                                                                                                                                    Reading

Automatic Parameter Adjustment Until Reading is Successful

Retry function

Code Readers must be able to read codes even for poor printing conditions. You can automatically retry reading                  while       changing  the  exposure     time

and other reading conditions, even for changing workpieces or environments, to enable a stable reading.

The following retry functions are provided.

1  Retrying the Specified Number of Times with the Same Conditions                                            NG                         N  G              OK

   Reading is performed the specified number of times for the same scene.

2  Retrying While External Trigger Is Input                                                                            During level trigger input

   Reading is performed until successful, as long as an external level trigger is input.                      NG                         NG                OK

3  Retrying While Changing the Shutter Speed                                                         NG                NG                      NG          OK

   Reading is performed for the same scene while changing the exposure time        in     stages.

                                                                                                     1ms               1.3ms                   0.7ms       1.6ms

4  Retrying While Changing the Reading Conditions                                                             NG                         NG                OK

   When reading DPM codes, inconsistencies in printing conditions can      result                             Scene 1           Scene 2                    Scene 3

   in NGs if reading is performed with only one set of reading settings.                             Register 32 sets of reading conditions.

   The FQ-CR allows you to register up to 32 sets of                                      Rapidly    switch to the optimum reading conditions.

   reading conditions as scenes and retry reading

   while changing the scenes in order.

   The system automatically determines the scenes

   with the highest usage rates and changes the order to start                     Scene 2           Scene 4           Scene 6           Scene 8           Scene    32

   with them to flexibly handle changes in reading conditions.

   Of course you can specify a fixed order if required.

                                                                           Scene   1        Scene 3           Scene 5           Scene 7               Scene 31

Easy Confirmation of Code Quality

Code Error Correction Position                           Display

Red circles are displayed on cells

for which the code was corrected on the display.

This clearly shows where the code quality was poor.
6

                FQ-CR1  FQ-CR2

                Stable  Reading  Functions  Packed  into a Compact Body

                                                    Polarization filter

                                                    Cuts specular reflections.

                                                    High power LEDs

                                                    Four times the brightness of previous models.

                                                    Lens and Camera

                                                    simple fine tuning of camera focus.

   Actual Size

                                                    Decoder

                                                    Built-in HDR function.

                                                    Robust housing: IP67

                                                    Ethernet Output

                                                    Output read codes on Ethernet.
                                                                                                                                             7

                                                                                                          Detection and Connection

Reads Codes Even with Low Contrast

High-power LEDs

The wider the field of view, the more difficult it is to maintain consistent

lighting within the field, causing errors in reading. The built-in LEDs of

the FQ-CR Series use a unique OMRON DR optical system for effective

light usage to maintain consistent lighting within the field of vision at a

brightness that is four times that of previous models.                        Previous Lighting             High-power Lighting

Cuts Light Interference

HDR Function

The HDR (high dynamic range) function minimizes the influence of

changes  in  lighting  conditions  and  light  reflection.  This  enables

stable inspections even for materials that are difficult to light evenly,

such as metal parts or glossy films, or in locations subject to external      Halation                      Stable Detection for

light interference.                                                                                         Metal Surfaces Subject to

                                                                                                            Gloss and Inconsistent Lighting

Cuts Specular Reflections

Polarizing Filter

A polarizing filter is included to cut specular reflection from glossy

surfaces. This enables stable code reading even for metallic or other

glossy surfaces.                                                              Without Polarizing  Filter    With Polarizing Filter

Communications with Host Devices

Ethernet Connection

The compact body also provides an Ethernet connector so that you

can transfer read data and images via Ethernet. Smoothly transfer

data to PLCs, computers, or other host devices.

                                                                                                  &UIFSOFU
8

   FQ-CR1        FQ-CR2

   Essentially, Simple Enough for Anyone to Set                                                           Up

   Setup is as easy as displaying codes on the monitor and registering settings with a simple procedure.

   Then, the FQ-CR will automatically tune the settings to achieve the optimum conditions.

   You can automatically tune all of these reading conditions just by making the basic settings.

                               Optimum Tuning in Three Steps

                 Read a code.                                                                             Select the type of code.

                                                                                            Two Set-up Tools

                                    Use the convenient Touch Finder

                                    for on-site settings and control panel                                                     installations,

                                    or use a set-up tool on a computer.

   Touch Finder

                                                                                            TouchFinder for PC (Free)

                                                                                            After purchasing the Code Reader,

                               you  can download the TouchFinder for PC free from the                                          member’s website.
                                                                                                                                     9

                                                                                              Set-up and Adjustment

Exposure Time                                    Gain  Dynamic Range                          Filtering

Press the TEACH Button.                                Check to see if the conditions

                                                       are correct as a reference.

                                                                                              END

Menu Displays in Nine Languages                                                        Operation Navigation

The nine language support for menus means                                              Navigation menus for operating procedures

that you can easily introduce systems into                                             from image adjustment through to testing and

factory sites in other countries.                                                      starting operation are provided so that even

In addition, you can easily change the language                                        beginners can operate the Code Reader.

on a menu.

English                            German

Japanese                           French

Traditional Chinese                Italian                                             Setup

Simplified Chinese                 Spanish                                             flow

Korean
10

    FQ-CR1  FQ-CR2

    Flexible System Configuration

    Connect Up To Eight Code Readers

    The flexibly arrangeable platform can be used for

    simple configurations with one Code Reader for

    complex configurations with multiple Code Readers

    reading from different directions.

    Up to eight Code Readers can be controlled from the

    Touch Finder set-up console.

    Code Quality Management                                                                              File Logging

    The FQ-CR2 contains state-of-the-art algorithms that enable the reading of codes even                                            SD Card

    with poor reading quality. However, even if the code quality continues to deteriorate for                                        Cell recognition rate

                                                                                                                                     Up to 10 million measurement

    some reason, auto-correction and retrying are used to enable reading, making it                                                  values or more

    impossible to tell where quality was lost simply from the OK/NG reading information.                                             (for a 4-GB SD card)

                                                                                                                                     Up to 10,000 images or more

    Here, you can use the cell recognition rate information. The cell recognition rate changes                                       (for a 4-GB SD card)

    with code printing quality, position inconsistency, installation conditions, and noise. You

    can log the cell recognition rate and image together to manage quality trends. The                   Logging of Recent  Results

    logging of recent results is useful for testing when commissioning a line. Run through

    some sample products and log the cell recognition rate. You can then display the results

    in a time-based graph to see how much leeway there is in reading performance.                                                    Displays the most recent 1,000

                                                                                                                                     cell recognition rate in graph form.

    * For the FQ-CR1, the number of detected characters is logged instead of the cell recognition rate.
                                                                                                                                                      11

                                                                                        Commissioning and Operation

                                                                   Match your field of viewɹ

                                                                   No matter whether you handle large or small workpieces, the range of Omron

                                                                   FQ-CR Code Readers offers a perfect match. Select the FQ-CR model with the

                                                                   appropriate range and adjust the field of view to your application. Focusing is

                                                                   quick and easy too, enabling you to use the sensor for a variety of applications.

                                                                                               Field of vision             13

                                                                                                         7.5

                                                                                                                      4.7          8.2

                                                                      Narrow view                                38            57

                                                                                               0

                                                                                              Field of vision                  53

                                                                                                             13                         33

                                                                      Standard                                   8.2               215

                                                                                                             56

                                                                                           0

                                                                                                                                   240

                                                                                        Field of vision

Touch Finder                                                                                                                                153

                                                                                           53

                                                                      Wide View                          33                             970

                                                                      (long-distance)   0         220

                                                                                                                                   300

                                                                                        Field of vision                                     191

                                                                                           29

                                                                      Wide View                          18                             380

                                                                      (short-distance)  0         32

                                             TouchFinder  for  PC

Automatic Notification of NGs

If you leave the Touch Finder installed on-site, the

recent NG sensor display is very useful. Even if you

are monitoring more than one Code Reader with                      

the Touch Finder, the display automatically

changes to the Code Reader where an NG occurred

so that you can quickly confirm conditions.
12  System Configuration

    Connections for One Code Reader

    Control by parallel input/output                                                                           Control by            Ethernet

                                        FQ-CR                                                                                                  FQ-CR Ethernet Cables           I/O  Cables

    Touch Finder                       Code Reader                       Sensor trigger                                                                                 FQ-CR                    Sensor trigger

                                                                                                                    Touch Finder               Switching         Code Reader

                                                                                                                                                   Hub

                                                                         PLC

                                                                         Power Supply 24 VDC                                                                                                     Power Supply 24 VDC

         FQ-CR Ethernet Cables                I/O Cables                                                       Standard Ethernet Cables                                                          PLC

                                                                                                               (RJ-45 of the FCC regulations)                    Standard Ethernet Cables

                                                                                                                                                            (RJ-45 of the FCC regulations)

    Connections for Multiple Code Reader

    Control by parallel input/output                                                                           Control by Ethernet

                                                    Up to 32 Code Reader can be connected.                                                                       Up to 32 Code Reader can be connected.

                                                                                                                                         FQ-CR Ethernet Cables

    Touch Finder                   Switching                                                                   Touch Finder                    Switching

                                       Hub                                                                                                         Hub

                                                                         Connect the trigger                                                                                                         Connect the trigger

            Standard Ethernet Cables                                     sensor, power supply                                                                                               PLC      sensor, power supply

                                                                         to each Code Reader.                          Standard Ethernet Cables             Standard Ethernet Cables

         (RJ-45 of the FCC regulations)        FQ-CR Ethernet Cables                                                   (RJ-45 of the FCC regulations)       (RJ-45 of the FCC regulations)           to each Code Reader.

    Note: If you register as a member after purchasing a Code Reader,                                         you can download the free set-up              software TouchFinder                     for PC that runs on

         a PC and can be used in place of the Touch Finder.                                         Refer to  the member registration sheet for             details.

    Ordering Information

    Code Reader                                                                                                                                                                                                  (Unit: mm)

    Narrow View                                           Standard                                             Wide View                                                (Short-distance)

                                                                                                               (Long-distance)

                                                                                                                                                       240                                                       300

                                                                         Field of vision        53

         Field of vision       13                                                                                   Field of vision                                                 Field of vision

                  7.5                                                                               33                                                      153                                                            191

                                   8.2                                        13                                       53                                                                   29

                          4.7      57                                             8.2               215                              33                     970                                      18                   380

                       38      to                                             56            to                               220               to                                                32      to

         0                                                            0                                             0                                                               0

                  2D Code              Multi Code                        2D Code                Multi Code             2D Code                 Multi Code                                   2D Code              Multi Code

                  Reader                    Reader                            Reader                Reader             Reader                      Reader                                   Reader               Reader

    NPN  FQ-CR20010F-M                 FQ-CR10010F-M      NPN         FQ-CR20050F-M             FQ-CR10050F-M  NPN  FQ-CR20100F-M              FQ-CR10100F-M            NPN           FQ-CR20100N-M              FQ-CR10100N-M

    PNP  FQ-CR25010F-M                 FQ-CR15010F-M      PNP         FQ-CR25050F-M             FQ-CR15050F-M  PNP  FQ-CR25100F-M              FQ-CR15100F-M            PNP           FQ-CR25100N-M              FQ-CR15100N-M

    Note: Tolerance (field of vision): ±10% max.

    Touch Finder                                                                                               Accessories

                                       Type                                                 Model              Application               Appearance                            Name                              Model

    DC power supply                                                           FQ2-D30                                                                            Mounting Bracket                                FQ-XL

    AC/DC/battery                                                             FQ2-D31 (See note.)                                                                (enclosed with Code Reader)

    Note: AC Adapter and Battery are sold separately.                                                          For Code                                          Mounting Bracket for

    Cables (Robot cable)                                                                                       Reader                                            highprecision sensing *1                        FQ-XL2

                                                                                                                                                                 (sold separately)

                       Type                               Cable length                      Model                                                                Polarizing Filter Attachment                    FQ-XF1

    FQ Ethernet Cables                              2m                        FQ-WN002                                                                           (enclosed with Code Reader)

    (connect Code Reader to Touch                   10 m                      FQ-WN010

    Finder, Code Reader to PC)                      20 m                      FQ-WN020                                                                           Panel Mounting Adapter                          FQ-XPM

                                                    2m                        FQ-WD002

    I/O Cables                                      10 m                      FQ-WD010                                                                           AC Adapter                                      FQ-AC1

                                                    20 m                      FQ-WD020                                                                           (for models for DC/AC/Battery)

    Industrial Switching Hubs (Recommended)                                                                                                                      Battery *2                                      FQ-BAT1
                                                                                                                                                                 (for models for DC/AC/Battery)
                                                                                                               For Touch
    Appearance             Number              Failure    Current                             Model
                                                                                                               Finder
                           of ports           detection   consumption                                                                                            Touch Pen
                                                                                                                                                                                                                 FQ-XT
                                                                                                                                                                 (enclosed with Touch Finder)

                           3                  None        0.22 A                  W4S1-03B

                                                                                                                                                                 Strap                                           FQ-XH

                                              None                                W4S1-05B

                           5                              0.22 A

                                              Supported                           W4S1-05C                                                                       SD Card (2 GB)                                  HMC-SD291

                                                                                                               *1. A mounting Bracket with improved resistance to vibrations and other external
                                                                                                                    stresses that cause displacement of the optical axis and field of view.

                                                                                                               *2. The Battery uses a lithium ion secondary battery. Confirm any applicable
                                                                                                                    laws and regulations in the destination country if you export the Battery.
Ratings and Performance                                                                                                                                             13

Code Reader

Item                                          Type                     2D Code Reader                                      Multi Code Reader

Model            NPN                                                  FQ-CR20@@@@-M                                        FQ-CR10@@@@-M

                 PNP                                                  FQ-CR25@@@@-M                                        FQ-CR15@@@@-M

Field of vision                                     Refer to the table below.

Installation distance

Minimum resolution                                  FQ-CR2@010F-M/-CR1@010F-M: 0.040 mm FQ-CR2@050F-M/-CR1@050F-M: 0.070 mm

                                                    FQ-CR2@100F-M/-CR1@100F-M: 0.282 mm FQ-CR2@100N-M/-CR1@100N-M: 0.155 mm

                                                                                                              2D Code (DataMatrix (EC200), QR Code, MicroQR

                                                                                                              Code, PDF417, MicroPDF417, GS1-DataMatrix)

                                                                                                              Bar code (JAN/EAN/UPC, Code39,

                                                                                                              Codabar (NW-7), ITF (Interleaved 2 of 5),

                 Code                               2D Code (DataMatrix (EC200), QR Code)                     Code 93, Code128/GS1-128, GS1 DataBar*

                                                                                                              (Truncated, Stacked, Omni-directional, Stacked

                                                                                                              Omni-directional, Limited, Expanded and Expanded

                                                                                                              Stacked), Pharmacode and GS1-128 Composite

Main functions                                                                                                Code (CC-A, CC-B, CC-C))

                                                    Filter function (Smooth, Dilate, Erosion,Median),

                 Image filter                       Retry function, Code Error Correction Position            None

                                                    Display

                 Verification function              None                                                      Supported

                 Number of simultaneous             32

                 inspections

                 Number of registered scenes        32

                 Image filter                       High dynamic range (HDR), polarizing filter (attachment)

Image input      Image elements                     1/3-inch monochrome CMOS

                 Shutter                            1/250 to 1/32,258 s                                       1/250 to 1/30,000 s

                 Processing resolution              752 × 480

                 Lighting method                    Pulse

Lighting         Lighting color                     White

                 LED class                          Risk Group 2 (IEC62471)

Data logging     Measurement data                   In Code Reader:1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.)

                 Images                             In Code Reader:20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.)

Measurement      trigger                            External trigger (single or continuous)

                                                    7 signals

                 Input signals                         • Single measurement input (TRIG)

                                                       • Control command inputs (IN0 to IN5)

                                                    3 signals

                                                       • Control output (BUSY)

I/O              Output signals                        • Overall judgement output (OR)

specifications                                         • Error output (ERROR)

                                                    Note:    The three output signals can be allocated for the judgements of individual inspection items.

                 Ethernet specification             Numerical outputs and control commands are supported with no-protocol communications.

                                                    100BASE-TX/10BASE-T

                                                    Special connector cables

                 Connection method                     • Power supply and I/O:          1 cable  (FQ-WD@@@)

                                                       • Touch Finder and computer:     1 cable  (FQ-WN@@@)

Ratings          Power supply voltage               21.6 to 26.4 VDC (including ripple)

                 Current consumption                2.4 A max.

                                                    Operating: 0 to 50°C

                 Ambient temperature range          Storage:    −25 to 65°C

Environmental                                       (with no icing or condensation)

immunity         Ambient humidity range             Operating and storage: 35% to 85% (with no condensation)

                 Ambient atmosphere                 No corrosive gas

                 Degree of protection               IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted.)

                                                    Code Reader:                     PBT, PC, SUS

                                                    Mounting Bracket:                PBT

Materials                                           Polarizing Filter Attachment:    PBT, PC

                                                    Ethernet connector:              Oil-resistance vinyl compound

                                                    I/O connector:                   Lead-free heat-resistant PVC

                                                       • Mounting Bracket (FQ-XL) (1)                         • Member registration sheet

Accessories                                            • Polarizing Filter Attachment (FQ-XF1) (1)

                                                       • Instruction Manual

           2D Code Reader                   Multi Code Reader                        Field of view

       NPN                PNP            NPN                   PNP                   (See note)                     Installation distance                  Weight

                                                                                (Horizontal × Vertical)

FQ-CR20010F-M    FQ-CR25010F-M          FQ-CR10010F-M   FQ-CR15010F-M        7.5 × 4.7 to 13 × 8.2 mm    38 to 57 mm

FQ-CR20050F-M    FQ-CR25050F-M          FQ-CR10050F-M   FQ-CR15050F-M        13 × 8.2 to 53 × 33 mm      56 to 215 mm                         200 g max.

FQ-CR20100F-M    FQ-CR25100F-M          FQ-CR10100F-M   FQ-CR15100F-M        53 × 33 to 240 × 153 mm     Long-distance model: 220 to 970 mm

FQ-CR20100N-M    FQ-CR25100N-M          FQ-CR10100N-M   FQ-CR15100N-M        29 × 18 to 300 × 191 mm     Short-distance model: 32 to 380 mm

Note: Tolerance: ±10% max.
14

    Touch Finder

                                                      Type              Model with DC power supply                              Model with AC/DC/battery power supply

    Item                                    Model                                   FQ2-D30                                                 FQ2-D31

    Number of connectable Sensor                             Number of sensors that can be recognized (switched): 32 max. number or sensor that can displayed on

                                                             monitor: 8 max.

                      Types of measurement displays          Last result display, Last NG display, trend monitor, histograms

    Main functions    Types of display images                Through, frozen, zoom-in, and zoom-out images

                      Data logging                           Measurement results, measured images

                      Menu language                          English, German, French, Italian, Spanish, Traditional Chinese, Simplified Chinese, Korean, Japanese

                                 Display device              3.5-inch TFT color LCD

                      LCD        Pixels                      320 × 240

    Indications                  Display colors              16.7 million

                                 Life expectancy *1          50,000 hours at 25ºC

                      Backlight  Brightness adjustment       Provided

                                 Screen saver                Provided

    Operation         Touch      Method                      Resistance film

    interface         screen     Life expectancy *2          1,000,000 touch operations

    External          Ethernet                               100BASE-TX/10BASE-T

    interface         SD card                                SDHC-compliant, Class 4 or higher recommended

                                                                                                                        DC power connection: 21.6 to 26.4 VDC

                                                             DC power connection:21.6 to 26.4 VDC                       (including ripple)

                      Power supply voltage                   (including ripple)                                         AC adapter (manufactured by Sino-American Japan

                                                                                                                        Co., Ltd) connection: 100 to 240 VAC, 50/60 Hz

    Ratings                                                                                                             Battery connection: FQ-BAT1 Battery (1cell, 3.7 V)

                      Continuous operation on Battery *3                                ---                             1.5 h

                      Power consumption                      DC power connection: 0.2 A max.                            DC power connection: 0.2 A max.

                                                                                                                        Charging battery:            0.4 A max.

                                                             Operating: 0 to 50ºC                                       Operating: 0 to 50ºC when mounted to DIN Track or panel

                      Ambient temperature range              Storage:      −25 to 65ºC                                  Operation on Battery: 0 to 40ºC

                                                             (with no icing or condensation)                            Storage:                     −25 to 65ºC

                                                                                                                        (with no icing or condensation)

    Environmental     Ambient humidity range                 Operating and storage: 35% to 85% (with no condensation)

    immunity          Ambient atmosphere                     No corrosive gas

                      Vibration resistance (destruction)     10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions

                                                             8 min each, 10 times

                      Shock resistance (destruction)         150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward)

                      Degree of protection                   IEC 60529 IP20 (when SD card cover, connector cap, or harness is attached)

    Weight                                                   Approx. 270 g (without Battery and hand strap attached)

    Materials                                                Case: ABS

    Accessories included with Touch Finder                   Touch Pen (FQ-XT), Instruction Manual

    *1.  This is a guideline for the time required for the brightness to diminish to half the initial brightness at room temperature and humidity. The life of the backlight is

         greatly affected by the ambient temperature and humidity and will be shorter at lower or higher temperatures.

    *2.  This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions.

    *3.  This value is only a guideline. No guarantee is implied. The value will be affected by the operating environment and operating conditions.

    Battery Specifications

    Item                                              Model                                                            FQ-BAT1

    Battery type                                             Secondary lithium ion battery

    Nominal capacity                                         1,800 mAh

    Rated voltage                                            3.7 V

    Ambient temperature range                                Operating: 0 to 40ºC

                                                             Storage:      −25 to 65ºC (with no icing or condensation)

    Ambient humidity range                                   Operating and storage: 35% to 85% (with no condensation)

    Charging method                                          Charged in Touch Finder (FQ-D31). AC adapter (FQ-AC@) is required.

    Charging time (See note 1.)                              2h

    Battery backup life (See note 2.)                        300 charging cycles

    Weight                                                   50 g max.

    Note: 1.   This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions

          2.   This is a guideline for the time required for the capacity of the Battery to be reduced to 60% of the initial capacity. No guarantee is implied.

               The value will be affected by the operating environment and operating conditions.

    System Requirements for TouchFinder for PC

    The following Personal Computer system is required to use the software.

    OS                                                       Microsoft Windows XP Home Edition/Professional SP2 or higher             (See note 1.)

                                                             Microsoft Windows 7 Home Premium or higher                (See note 1.)

    CPU                                                      Core 2 Duo 1.06 GHz or the equivalent or higher

    RAM                                                      1GB min.

    HDD                                                      500 MB min. available space      (See note 2.)

    Monitor                                                  1,024 × 768 dots min.

    Note: 1.   The Japanese and English versions support only 32-bit OS versions.

          2.   Available space is also required separately for data logging.
Dimensions                                                                                                                                                                                              (Unit: mm)             15

Code Reader                     (Dimensional drawings are provided here only for the          products    that have undergone design changes as of June 2012.)

FQ-CR

Mounting with the           FQ-XL Mounting Bracket                                                        Mounting with the FQ-XL2 Mounting                                     Bracket

                                                                                                                                                    (57)

                                                                                                          Optical axis

                  46                                                 Mounting Bracket                                                                              (65)                   59

                                               1                                                                                                                                          20±0.1

OPTICAL                                                                                                           5                                                      (108)

AXIS                                                                                                      67                                                                                            20±0.1

                            45                                                                                40  30                                                                                            38.8

                                                                         (108)                                                                                                  Four-M4           1/4-20UNC

      67                    Polarizing                                                                                                                                          Depth: 6          Depth: 6

                            Filter Attachment                        32

                                                                                                                                                    Four machine screws

                                                                     9                                                                       Plate  (double pan-head set screws)

                                                                                                                                    Cushion                     t1 Base

                            (See note 1.)                         8  18                                                                                                         Mounting          Hole Dimensions

                                                  38                                                                                                                                              Two, 4.5 dia.

                                               (See note 2.)

                                                                                                                                        41   38

                                                                                                                                                                                          20±0.1

                                                                  Mounting Hole Dimensions

                                                                                              20±0.1                                                49          8

                                                                  Two, 4.5 dia.

                                                                     Tightening     torque: 1.2 N.m

* Dimentions            with the FQ-XL Mounting Bracket

            Type                        Model                        Note       1.  Note 2.

Narrow View,            FQ-CR1@010F-M/-CR2@010F-M/                       11            57

Standard                -CR1@050F-M/-CR2@050F-M

Wide View               FQ-CR1@100F-M/-CR2@0100F-M/                      3             49

                        -CR1@100N-M/-CR2@100N-M

Touch Finder

FQ2-D30/-D31                                                                                                                                        Panel Mounting Adapter

                                                                                                                                                                                                  (36.9)

                                                                                                                                                                                          (2)     31.6

                                                                                                                                                                                3.5

                                                                                              20

                                                                                                                                                           116

                                                                     44.5                                                                                  95

                                                              95                 (See note.)

                  33                                          70

                                                                                                                               116  85                                                                                (133.4)

35.5                                                                                          52.9    85

      14

27.9  23.8

                                                                                                                                                                                (8.1)

                                                                                                                                        Panel Cutout Dimensions

12.1              13.5  15                                                                                                                          111±1

                                                      27

                                                          10

                            19.2  17.3                                                                                  111±1                                                   Panel

                                        (See note.)

Note:       Provided with   FQ2-D31 only.
READ AND UNDERSTAND THIS DOCUMENT

Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of

sale by OMRON.

OMRON       MAKES    NO  WARRANTY   OR   REPRESENTATION,   EXPRESS           OR    IMPLIED,   REGARDING  NON-INFRINGEMENT,                  MERCHANTABILITY,  OR  FITNESS    FOR

PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED

WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN  NO      EVENT  SHALL  OMRON     BE   RESPONSIBLE  FOR  WARRANTY,               REPAIR,    OR  OTHER  CLAIMS                  REGARDING  THE  PRODUCTS     UNLESS       OMRON’S

ANALYSIS    CONFIRMS      THAT      THE  PRODUCTS  WERE    PROPERLY                HANDLED,   STORED,    INSTALLED,              AND  MAINTAINED     AND   NOT    SUBJECT    TO

CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED.                                 THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF

PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.                                                 Please refer to separate

catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use

of the product.

At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This

information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other

application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the

products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,

and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A

WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED

USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of

OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of

Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some

specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your

application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or

proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any

manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.

Note: Do not use this document to operate the Unit.

OMRON Corporation                        Industrial Automation  Company                                  Authorized Distributor:

    Tokyo, JAPAN

                         Contact:   www.ia.omron.com

Regional Headquarters

OMRON EUROPE B.V.                                  OMRON ELECTRONICS LLC

Wegalaan 67-69-2132 JD Hoofddorp                   One Commerce Drive Schaumburg,

The Netherlands                                    IL 60173-5302 U.S.A.

Tel: (31)2356-81-300/Fax: (31)2356-81-388          Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.                       OMRON (CHINA) CO., LTD.                               © OMRON Corporation 2011                    All Rights Reserved.

No. 438A Alexandra Road # 05-05/08 (Lobby 2),      Room 2211, Bank of China Tower,                       In the interest of product improvement,

Alexandra Technopark,                              200 Yin Cheng Zhong Road,                             specifications are subject to change without notice.

Singapore 119967                                   PuDong New Area, Shanghai, 200120, China              CSM_14_1_0615

Tel: (65) 6835-3011/Fax: (65) 6835-2711            Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200         Cat. No. Q186-E1-01                                      0811 (0811)
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

FQ-S10010F   FQ-S10050F  FQ-S10100F  FQ-S10100N  FQ-S15010F  FQ-S15050F  FQ-S15100F  FQ-S15100N

FQ-S20010F   FQ-S20050F  FQ-S20100F  FQ-S20100N  FQ-S25010F  FQ-S25050F  FQ-S25100F  FQ-S25100N  FQ-

D30  FQ-D31  FQ-AC2     FQ-WN002  FQ-WD002

小广播

FQ-D30器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved