电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

EV-NV-00

器件型号:EV-NV-00
器件类别:开发板/开发套件/开发工具   
文件大小:17829.89KB,共47页
厂商名称:Skyetek
标准:  
下载文档

器件描述

eval kit for nova uhf rfid

参数
Datasheets:
Nova Datasheet Preliminary:
Nova Brochure:
Standard Package : 1
Category: RF/IF and RFID
Family: RFID Evaluation and Development Kits, Boards
Series: SkyeModule™ Nova
Type: Read/Write
Frequency: 860MHz ~ 960MHz
For Use With/Related Products: SkyeModule™ Nova Modules
Supplied Contents: Board
Dynamic Catalog: EV-NV-00 Evaluation Kit
Other Names: 753-1028

EV-NV-00器件文档内容

SKYEMODULE  NOVA  DATASHEET

                  PRELIMINARY

                  VERSION 031014
SkyeModule Nova Datasheet - Preliminary                                                                                                                           Page |  2

COPYRIGHT INFORMATION:

Copyright 2014 SkyeTek, Inc., 1732 Wazee St. Suite 202, Denver, Colorado 80202, U.S.A. All rights reserved.

Version 031014

This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this

product or document may be reproduced in any form by any means without prior written authorization of SkyeTek and its licensors, if any.

SkyeTek and SkyeWare are trademarks or registered trademarks of SkyeTek, Inc.

MIFARE and NXP is a registered trademark of Royal Philips Electronics.

MicroSoft and Windows are registered trademarks of Microsoft Corporation.

TECHNICAL SUPPORT AND CONTACT INFORMATION

SkyeTek, Inc.

1732 Wazee St. Suite 202

Denver, CO 80202

http://www.skyetek.com

SALES:

sales@skyetek.com

TECHNICAL SUPPORT:

support@skyetek.com

                                                                                                                                          Skyetek Inc

                                                                                                             1732 Wazee St. Ste 202

                                                                                                             Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                           www.skyetek.com
SkyeModule Nova Datasheet - Preliminary  Page | 3

TABLE OF CONTENTS

1   INTRODUCTION .............................................................................................................................................. 7

    1.1   GETTING STARTED ..............................................................................................................................................7

    1.2   WHY A SKYETEK MODULE? ..................................................................................................................................7

    1.3   ADDITIONAL READING .........................................................................................................................................8

    1.4   REVISION HISTORY ..............................................................................................................................................9

2   DEFINITION OF TERMS ................................................................................................................................. 10

3   APPLICATIONS............................................................................................ERROR! BOOKMARK NOT DEFINED.

4   ORDERING INFORMATION ........................................................................................................................... 11

    4.1   NOVA STANDARD PART NUMBERS .......................................................................................................................11

    4.2   PART NUMBER DETAILS .....................................................................................................................................11

    4.3   HOW TO BUY...................................................................................................................................................12

5   SKYEMODULE NOVA OVERVIEW .................................................................................................................. 13

    5.1   DESCRIPTION.................................................................................................................................................. 13

    5.2   BLOCK DIAGRAM ..............................................................................................................................................13

    5.3   FEATURES ........................................................................................................................................................ 13

    5.4   APPLICATIONS ..................................................................................................................................................14

    5.5   AGENCY APPROVALS .........................................................................................................................................14

6   MECHANICAL SPECIFICATIONS ..................................................................................................................... 15

7   PINNING INFORMATION .............................................................................................................................. 16

    7.1   CONNECTOR DESCRIPTIONS ................................................................................................................................16

    7.2   HOST INTERFACE CONNECTOR PIN MAPPING .........................................................................................................17

    7.3   USING THE GPIO PINS ......................................................................................................................................18

8   ENVIRONMENTAL SPECIFICATIONS .............................................................................................................. 19

    8.1   ELECTROSTATIC PRECAUTIONS.............................................................................................................................19

    8.2   GENERAL RATINGS AND OPERATING CONDITIONS ...................................................................................................19

9   ELECTRICAL SPECIFICATIONS ........................................................................................................................ 20

    9.1   ELECTRICAL CHARACTERISTICS .............................................................................................................................20

    9.2   ABSOLUTE MAXIMUM RATINGS...........................................................................................................................21

10        PERFORMANCE SPECIFICATIONS .............................................................................................................. 22

    10.1  RANGE SPECIFICATIONS......................................................................................................................................22

11        RADIO SPECIFICATIONS ............................................................................................................................ 23

    11.1  AGENCY APPROVALS .........................................................................................................................................23

    11.2  FREQUENCY BAND ............................................................................................................................................23

    11.3  TAG PROTOCOLS ..............................................................................................................................................23

                                         Skyetek Inc

                                         1732 Wazee St. Ste 202

                                         Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400       www.skyetek.com
SkyeModule Nova Datasheet - Preliminary  Page | 4

12        HOST INTERFACE SPECIFICATIONS ............................................................................................................ 24

    12.1  USB 2.0.........................................................................................................................................................25

    12.2  TTL SERIAL......................................................................................................................................................26

    12.3  SPI ................................................................................................................................................................27

    12.4  I2C ................................................................................................................................................................. 30

13        SKYEMODULE NOVA ANTENNA OPTIONS................................................................................................. 33

14        COMMUNICATING WITH THE MODULE .................................................................................................... 34

    14.1  HOST COMMUNICATION (SKYETEK PROTOCOL V3)..................................................................................................34

    14.2  REQUEST FORMATS...........................................................................................................................................34

    14.3  RESPONSE FORMATS .........................................................................................................................................35

15        SYSTEM PARAMETERS .............................................................................................................................. 36

    15.1  SYSTEM PARAMETER SUMMARY..................................................................................................................36

    15.2  CHANGING SYSTEM PARAMETERS ........................................................................................................................37

    15.3  SYSTEM PARAMETER DETAILS..............................................................................................................................37

16        SPECIAL FEATURES .................................................................................................................................. 47

    16.1  SLEEP MODES ..................................................................................................................................................47

    16.2  FEATURE REQUESTS ..........................................................................................................................................47

                                         Skyetek Inc

                                         1732 Wazee St. Ste 202

                                         Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400       www.skyetek.com
SkyeModule Nova Datasheet - Preliminary  Page | 5

LIST OF FIGURES

Figure 3-1: SkyeTek Part Number Format ...................................................................................................................11

Figure 4-1: SM-GM-AC (with all connectors) ...............................................................................................................13

Figure 4-2: SkyeModule Nova Block Diagram..............................................................................................................13

Figure 5-1: SM-GM Mechanical Drawing.....................................................................................................................15

Figure 6-1: Host Interface Connector Pin Numbering .................................................................................................17

Figure 9-2: Range Specifications..................................................................................................................................22

Figure 11-1: USB Connection Diagram ........................................................................................................................25

Figure 11-2: TTL Serial Connection Diagram................................................................................................................26

Figure 11-3: TTL Serial Timing Diagram .......................................................................................................................26

Figure 11-4: SPI Connection Diagram ..........................................................................................................................27

Figure 11-5: SPI Request Setup and Sample Timing ....................................................................................................27

Figure 11-6: SPI Request Timing ..................................................................................................................................28

Figure 11-7: SPI Response Timing................................................................................................................................29

Figure 11-8: I2C Connection Diagram...........................................................................................................................30

Figure 11-9: I2C Timing Diagram ..................................................................................................................................32

                                         Skyetek Inc

                                         1732 Wazee St. Ste 202

                                         Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400       www.skyetek.com
SkyeModule Nova Datasheet - Preliminary  Page | 6

LIST OF TABLES

Table 1-1: Revision History ............................................................................................................................................9

Table 3-1: Nova Standard Part Numbers .....................................................................................................................11

Table 3-2: Part Number Details ...................................................................................................................................11

Table 6-1: SkyeModule Nova Connector Specification................................................................................................16

Table 6-2: SkyeModule Nova Pin Descriptions ............................................................................................................17

Table 7-1: Environmental Ratings/Operating Conditions ............................................................................................19

Table 8-1: SkyeModule Nova Electrical Specifications ................................................................................................20

Table 8-2: Absolute Maximum Ratings........................................................................................................................21

Table 13-1: Request Format (bytes), ASCII Mode........................................................................................................34

Table 13-2: Request Format (bytes), Binary Mode......................................................................................................34

Table 13-3: Response Format (bytes), Binary Mode ...................................................................................................35

Table 14-1: SkyeModule Nova System Parameters.....................................................................................................36

Table 14-10: Common Power Values...........................................................................................................................41

Table 14-11: Commonly Used Frequencies .................................................................................................................43

Table 14-12: Common Modulation Depth Values .......................................................................................................45

Table 14-13: Regulatory Mode Values.........................................................................................................................46

                                         Skyetek Inc

                                         1732 Wazee St. Ste 202

                                         Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400       www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                            Page | 7

1    Introduction

1.1  Getting Started

Operating your SkyeModule Nova begins with finding a method to connect to a host. The SkyeModule itself does

not operate without direction (commands) from a host. The host can be in the form of a PC or, more typically, an

embedded microcontroller. This document explains the physical and electrical characteristics of the module, so

you can understand how to integrate the Nova into a finished product.

For initial demonstration of the module, SkyeWare v4 software is available on the media that came with the

developer/evaluation kit or available for download at support.skyetek.com. Open this software on your windows

PC and it will be recognized when you connect through USB or RS232 (with developer kit interface board). The

software demonstrates features like selecting tags, reading and writing. It also has a powerful command builder

that lets you format, send and receive any command to and from the reader. More about SkyeWare can be found

in the SkyeWare User Guide. See the Additional Reading section below.

The next step after demonstrating the module’s functionality is developing your own communication with the

module. This can be achieved with simple code on a microcontroller or using the SkyeTek API on a PC. Once

connected to a host through one of the four host interfaces, the reader to host communication is formatted with a

full featured protocol called SkyeTek Protovol v3. In order to make learning commands and formatting easy, we

have developed a series of application notes with examples to get you started. The application notes start with

basic tag and reader commands and become very detailed for tags with special features. Read more about the

protocol and commands in section 13, Communicating with the Module and then move on to the Additional

Reading in section 1.3.

1.2  Why a SkyeTek Module?

Many customers may wonder, “What value does a module add over an RFID transceiver chip?”

RFID transceiver chips may seem simple, but they actually require significant engineering time and capital

investment to integrate. Transceiver chips contain up to 50 registers for configuration and functionality. In

addition, communicating over air protocols such as ISO18000-6C is complex, described in nearly 150 pages of

cryptic procedures. For example, just selecting a tag requires a minimum of 6 and up to 100 over air interactions

with multiple tags present. SkyeTek has also optimized the complex RF chain to give the best performance and

efficiency possible. SkyeTek modules mask the complexities of RFID from the user and pack functionality into

just a few commands.

SkyeTek’s core set of commands allow the user to read and write to tags with a single command, regardless of the

tag type. The module is also field upgradable, so you can use the latest security algorithms and tag features as they

are released. Power regulation and filtering for the radio are handled in the Nova, so you can supply voltage

directly from an unregulated source like a battery. Finally, the Nova will be modularly approved by the FCC and CE,

so you can bypass expensive radio testing at a certified test lab and avoid potential schedule delays due to failures.

                                                                                                            Skyetek Inc

                                                                       1732 Wazee St. Ste 202

                                                                                          Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                        www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                    Page | 8

Using a SkyeTek module will greatly reduce time to market and upfront development costs. Allow SkyeTek to

take the burden of developing an RF system so you can focus your energy on your core products.

1.3  Additional Reading

SkyeTek Protocol v3 Reader Commands – Application note with descriptions and examples of the reader

commands: read/write system, read/write default system, load defaults, and reset

                                                                                                     Skyetek Inc

                                                                                  1732 Wazee St. Ste 202

                                                                                                Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                              www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                               Page | 9

1.4  Revision History

Revision  Author                         Change

031014    Josh Peifer                    Initial draft.

                                         Table 1-1: Revision History

                                                                      Skyetek Inc

                                                                      1732 Wazee St. Ste 202

                                                                      Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                    www.skyetek.com
SkyeModule Nova Datasheet - Preliminary       Page | 10

2       Definition of Terms

   3DES    Triple Data Encryption Standard

   AES     Advanced Encryption Standard

   API     Application Programming Interface

   DES     Data Encryption Standard

   GPIO    General Purpose Input/Output

   HID     Human Interface Device

   I2C     Inter-integrated Circuit

   LSB     Least Significant Bit

   MSB     Most Significant Bit

   NC      No Connect

   RoHS    Reduction of Hazardous Substances

   SPI     Serial Peripheral Interface

   SSEL    Slave Select

   STP V3  SkyeTek Protocol Version 3

   TTL     Transistor-transistor Logic

                                              Skyetek Inc

                                              1732 Wazee St. Ste 202

                                              Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400            www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                                 Page |       11

3    Ordering Information

3.1   Nova Standard Part Numbers

   Part Number  Host Interface      Baud Rate                      Description

   SM-NV-00     USB (HID)           12Mbps                         Mini PCI express connector

                                    Table 3-1: Nova Standard Part Numbers

NOTE – The Nova will always communicate via USB, when a USB host is connected.

3.2   Part Number Details

The Nova part number is constructed according to the SkyeTek part number specification below:

                                    PF-PT-BT-OPTS
                                    Product  FamPriolyduct  Build        Options
                                                                   Type
                                                            Type

                                    Figure 3-1: SkyeTek Part Number Format

Code            Options                                     Description

Product Family  SM = SkyeModule                             Highest level product family code.

Product Type    NV = NOVA                                   Specifies the specific part type.

Build Type                                                  Specifies hardware form factor.

Options         Blank = Standard                            This field is left for special customer part numbers or standard

                                                            variations such I2C for I2C as the default host interface.  Consult

                                                            the SkyeTek sales team for custom orders.

                                         Table  3-2:  Part Number Details

                                                                                                                        Skyetek Inc

                                                                                                1732 Wazee St. Ste 202

                                                                                                       Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                     www.skyetek.com
SkyeModule Nova Datasheet - Preliminary       Page | 12

3.3  How to Buy

SkyeTek products are distributed through a worldwide distribution network as well as directly through SkyeTek.

For more information on how to purchase SkyeTek products in your area, please visit the How To Buy page on the

SkyeTek website at www.skyetek.com/howtobuy.

                                              Skyetek Inc

                                              1732 Wazee St. Ste 202

                                              Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400            www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                  Page | 13

4    SkyeModule Nova Overview

4.1     Description

The SkyeModule™ Nova marks the next generation of SkyeTek UHF reader modules. The Nova is an ultra-

small, 2 port, 500mW EPC Class 1 Gen 2 reader/writer module. A cutting edge ARM Cortex microcontroller,

latest UHF transceiver technology and cutting edge adaptive antenna tuning coupled with the reader's

intelligent operating system make this module the most powerful and feature rich UHF reader module of its

size. Manufactured in accordance with ISO 9001 and ISO 13485, quality is a top priority for all SkyeTek

modules.

                                                 Figure 4-1: SM-NV-00

4.2     Block Diagram

                                                  [PICTURE]

                                    Figure 4-2: SkyeModule Nova Block Diagram

4.3     Features

       Selects, Reads and writes to transponders based on EPC Global Class 1 Gen 2v2 (ISO 18000-6C)

       Return Signal Strength Indicator (RSSI)

       2 antenna ports, each capable of 500mW output power

       Adaptive Antenna Tuning

       Mini PCIe half card form factor

       Wide and efficient power supply with input from 2.0 – 5.5V

       Deep sleep mode current down to 10uA

       Easy migration to and from the M7/M9/M10

       Supported host interfaces include USB, TTL level RS232, SPI, I2C

       Modularly certified (coming soon)

                                                                                                         Skyetek Inc

                                                                               1732 Wazee St. Ste 202

                                                                               Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                             www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                 Page | 14

4.4     Applications

       Mobile Computing

       Inventory and Asset Management

        o       Retail Inventory

        o       In Transit Inventory

       Access Control

4.5     Agency Approvals

       RoHS 2

       FCC Modular – Seeking approval

       CE Mark – Seeking approval

       Manufactured according to ISO9001 and ISO13485

                                                        Skyetek Inc

                                                        1732 Wazee St. Ste 202

                                                        Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                      www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                   Page | 15

5  Mechanical Specifications

   Dimensions: 25 mm x 30 mm = 750 mm2

   Height: 5 mm

                                         [PICTURE]

                                    Figure 5-1: SM-NV Mechanical Drawing

                                                                          Skyetek Inc

                                                                          1732 Wazee St. Ste 202

                                                                          Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                        www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                     Page | 16

6    Pinning Information

6.1  Connector Descriptions

The SM-NV-00 is the standard version of the Nova module and use the 52 pin Mini PCIe connector. In production,

customers can connect a host to the module in one of three ways:

   Connector Type      Description       Ref Des  Man.            Man. P/N    Mating Connector

   52 pin Mini PCIe    Host interface    J3       Molex           N/A         0679101002

                       connector

                          Table 6-1: SkyeModule Nova Connector Specification

Custom connectors and antenna configurations can be ordered with a minimum order quantity. Please contact a

SkyeTek sales representative or local reseller to discuss ordering options. For more information on how to

purchase SkyeTek products in your area, please visit the How To Buy page on the SkyeTek website at

SkyeTek.com/HowToBuy.

                                                                                                            Skyetek Inc

                                                                              1732 Wazee St. Ste 202

                                                                              Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                            www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                   Page | 17

6.2  Host Interface Connector Pin Mapping

The SkyeModule Nova host connector is a 52-pin Mini PCI Express edge connector. The pin numbers are       located as

illustrated in Figure 6-1 below. The pin mappings and descriptions are shown in Table 6-2. Note that all

unconnected pins should be left floating.

                                                         [PICTURE]

                           Figure 6-1: Host Interface Connector Pin Numbering

Pin  Name   Description                          I/O     Pin        Name        Description               I/O

1    NC     Not Connected                        N/A     2          VIN         Input Power Supply        Input

3    NC     Not Connected                        N/A     4          GND         Ground                    Input

5    NC     Not Connected                        N/A     6          NC          Not Connected             N/A

7    NC     Not Connected                        N/A     8          MISO        SPI Master In, Slave Out  Output

9    GND    Ground                               Input   10         MOSI        SPI Master Out, Slave In  Input

11   NC     Not Connected                        N/A     12         SCK         SPI Clock IN              Input

13   NC     Not Connected                        N/A     14         SSEL        SPI Slave Select          Input

15   GND    Ground                               Input   16         NC          Not Connected             N/A

17   NC     Not Connected                        N/A     18         GND         Ground                    Input

19   NC     Not Connected                        N/A     20         Deep Sleep  Active Low Deep Sleep     Input

21   GND    Ground                               Input   22         Reset       Active Low Reset          Input

23   NC     Not Connected                        N/A     24         VIN         Input Power Supply        Input

25   NC     Not Connected                        N/A     26         GND         Ground                    Input

27   GND    Ground                               Input   28         NC          Not Connected             N/A

29   GND    Ground                               Input   30         SCL         I2C Clock                 Input

31   NC     Not Connected                        N/A     32         SDA         I2C Data                  I/O

33   NC     Not Connected                        N/A     34         GND         Ground                    Input

35   GND    Ground                               Input   36         D-          USB D minus               I/O

37   GND    Ground                               Input   38         D+          USB D Plus                I/O

39   VIN    Input Power Supply                   Input   40         GND         Ground                    Input

41   VIN    Input Power Supply                   Input   42         GPIO0       General Purpose I/O 0     I/O

43   GND    Ground                               Input   44         GPIO1       General Purpose I/O 1     I/O

45   GPIO3  General Purpose I/O  3               I/O     46         GPIO2       General Purpose I/O 2     I/O

47   NC     Not Connected                        N/A     48         NC          Not Connected             N/A

49   RXD    UART Receive                         Input   50         GND         Ground                    Input

51   TXD    UART Transmit                        Output  52         VIN         Input Power Supply        Input

                                 Table     6-2:  SkyeModule Nova Pin Descriptions

                                                                                                          Skyetek Inc

                                                                                                  1732 Wazee St. Ste 202

                                                                                                       Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                     www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                    Page | 18

6.3     Using the GPIO Pins

You can use the User Port Direction and User Port Value system parameters to address the GPIO pins to set

the user port direction (input or output) and the user port value (high or low). For more information, see

the following:

       “User Port Direction” in section 14.3.9

       “User Port Value” in section 14.3.10

NOTE – GPIO3 is used as a data ready pin when in SPI or I2C mode. GPIO3 cannot be used as GPIO when using

these interfaces.

                                                 Skyetek Inc

                                                 1732 Wazee St. Ste 202

                                                 Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400               www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                             Page | 19

7    Environmental Specifications

7.1     Electrostatic Precautions

              CAUTION – Failure to take proper electrostatic precautions may result in damage to or failure of your

              SkyeModule Nova.

The SkyeModule Nova contains static-sensitive parts. Observe the following precautions to prevent damage to

these parts.

            Wear a static grounding strap when handling electronic control components.

            Keep all plastic, vinyl, and styrofoam (except antistatic versions) away from printed circuit boards.

            Do not touch the components or conductors on a printed circuit board with your hands or with

             conductive devices.

7.2     General Ratings and       Operating Conditions

   Specification                         Rating

   Temperature range                     Temperature is 25 degrees Celsius unless        otherwise  noted

   Operating                             -20 to +70 degrees C

   Storage                               -40 to +125 degrees C

   Humidity

   Operating, continuous storage         10-90 percent (non-condensing)

   Transient storage (<24 hours)         5-95 percent maximum (non-condensing)

   ESD protection                        < 1kV (ESD HBM 15500 Ω, 100pF) —or—

                                         100V (ESD MM 0.75uH, 200pF)

                                  Table 7-1: Environmental Ratings/Operating Conditions

                                                                                                                    Skyetek Inc

                                                                                         1732 Wazee St. Ste 202

                                                                                         Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                       www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                  Page | 20

8    Electrical Specifications

This chapter discusses the electrical specifications of the SkyeModule Nova. Unless otherwise      noted, the following

assumptions apply to these specifications:

       Temperature is 25 degrees Celsius.

       Frequency is 915 MHz.

       Supply voltage (VCC) is 5 V.

8.1     Electrical Characteristics

   Specification                                                  Min         Typ             Max  Units/Notes

   RF Characteristics

   Frequency ranges (Direct output)                                           860-960              MHz

   Transmission Parameters

   Transmit Power                                                             500                  mW

   Optimum PA Load Impedance                                                  50                   Ohms

   Logic Inputs

   High state input voltage                                       2.3                         5.0  V

   Low state input voltage                                        0                           1    V

   Input Current (IINH/IINL)                                                                  10   nA

   Logic Outputs

   Output High Voltage (VOH)                                      2.8         3.3             3.6  V

   Output Low Voltage (VOL)                                                                   0.4  V

   Output Current (IINH/IINL)                                                                 4    mA

   Power Supplies

   Voltage Supply                                                 2.0                         5.5  V

   Idle Current @ 5V Supply                                                   150                  mA

   Continuous Transmit Current @ 5V Supply                                    500                  mA

   Low Power Software Sleep Mode Current @  5V  Supply                        10                   mA

   Deep Sleep Mode Current @ 5V Supply                                        5                    uA

                                     Table 8-1: SkyeModule  Nova  Electrical  Specifications

                                                                                                      Skyetek Inc

                                                                                                 1732 Wazee St. Ste 202

                                                                                                   Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                 www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                              Page | 21

8.2  Absolute Maximum Ratings

Specification                                                                Rating

VSUPPLY to GND                                                               7.0 V

Digital I/O voltage to GND                                                   5.5 V

                                    Table  8-2:  Absolute  Maximum  Ratings

                                                                                     Skyetek Inc

                                                                                    1732 Wazee St. Ste 202

                                                                                     Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                   www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                      Page | 22

9    Performance Specifications

9.1  Range Specifications

The range measurements below should be used as a guideline and not a guarantee. Environment can play a major

role on tag range performance. Be sure to avoid any conductor in or near the field, as eddy currents can

significantly reduce energy transfer between the reader antenna and the tag.

   Specification                               Min                            Typ  Max                    Units/Notes

   Select Tag Range (6dBi Broad Band Antenna)

   Avery Dennison Label, Monza 3 Chip                                         6    10                     m

                                         Figure 9-1: Range Specifications

WARNING: Read ranges are not guaranteed and are subject to change without warning due to tag silicon or inlay

variations.

                                                                                                             Skyetek Inc

                                                                                   1732 Wazee St. Ste 202

                                                                                        Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                      www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                     Page | 23

10    Radio Specifications

10.1   Agency Approvals

As part of a host system, the SkyeModule Nova will not interfere with the overall system’s compliance with

agency requirements for emissions and susceptibility, including:

      United States: Seeking FCC 15.247 modular approval

      Europe: Seeking EN302-208, EN301-489, EN 61000-4-3

      RoHS

10.2   Frequency Band

The Nova operates in the 860-960MHz band. Allowed frequency bands and channels are subject to regional

regulatory standards. Operating frequency of the Nova is software adjustable.

10.3   Tag Protocols

The SkyeModule Nova supports at least the basic tag commands (select, read, and write) for EPC Class 1 Gen 2

(ISO 18000-6C) compliant tags.  For the most current listing of supported tags and features, see the SkyeModule

Nova Tag Support List.

                                                                               Skyetek Inc

                                                                               1732 Wazee St. Ste 202

                                                                               Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                             www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                  Page | 24

11  Host Interface Specifications

The SkyeModule Nova supports the following microcontroller host interfaces for easy integration into existing

systems:

         USB (Overrides other interfaces when connected)

         TTL Serial

         SPI

         I2C

The SkyeModule Nova and the host interface board support TTL Serial and USB communications. The host

interface board provides a USB connector and a TTL to RS-232 level converter for the TTL Serial host interface. The

Host Interface system parameter determines which host interface is used to communication with the h ost.

Each interface is software selectable and only one host interface is active at a time, however, USB may

always be connected and overrides the current interface. The host interface is selected based on the

power-up default value and can be changed at run time. The SkyeModule Nova operates under host control

using SkyeTek Protocol v3 sent over one of the host interfaces described in this chapter.

The following sections describe the power and host communication connections for the SkyeModule Nova. The

SkyeTek Protocol and commands are described further in section 13, Communicating with the Module.

                                                                                                   Skyetek Inc

                                                                                           1732 Wazee St. Ste 202

                                                                                           Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                         www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                      Page | 25

11.1  USB 2.0

As a USB device, the host detects the SkyeModule Nova as an HID device. The SkyeModule Nova uses a standard

HID driver but is not a certified USB device. The SkyeModule Nova supports both standard and high speed USB

hosts and enumerates correctly on both Windows and UNIX platforms.  The USB interface is typically only used

for demonstration as a USB host controller is not usually available for in embedded systems. To communicate

with the reader in USB mode, either SkyeTek demonstration software or the SkyeTek APIs can be used. See the

SkyeTek support site for the latest software and API downloads at support.skyetek.com.

Figure 11-1 shows an example of a circuit to permit USB communications without using the host interface board.

                                         [PICTURE]

                                    Figure 11-1: USB Connection Diagram

NOTE – If powered by USB, the USB host must be capable of supplying the USB standard high power device,

500mA at 5V.

                                                                                        Skyetek Inc

                                                                                        1732 Wazee St. Ste 202

                                                                                        Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                      www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                             Page | 26

11.2    TTL Serial

A two-wire serial connection (no handshaking) is provided on the TXD and RXD lines where TXD and RXD are from

the module's point of view. Data exchange between the host and the SkyeModule Nova occurs according to

SkyeTek Protocol v3 (ASCII or Binary mode).         See more about the protocol in section  13, Communicating with

the Module.

Serial communication is the most common and robust host interface for this module in an embedded

system.  Because the interface is asynchronous, the module responds immediately upon command

completion instead of waiting for a host clock as in SPI or I2C.

Figure 11-2 shows a sample circuit that lets you connect the SkyeModule Nova without the host interface board.

Figure 11-3 shows examples of typical communication on a signal level.

                                                    [PICTURE]

                                    Figure 11-2: TTL Serial Connection Diagram

                                Tbit = 1/BAUD RATE

HIGH

                    Start  LSB                                                              MSB  Stop

LOW

                                                          8-bit Data

                                    Figure 11-3: TTL Serial Timing Diagram

Notes:

        Baud rate is selectable via the appropriate system parameter. Preprogrammed factory default baud rate

         is 38,400 Baud.

        Bytes are transmitted least-significant bit (LSB) first using the typical serial data format of Start Bit

         followed by 8 data bits followed by a Stop Bit.

        The TTL Serial connection supports bit rates from 9,600 to 115,200 Baud, 8 data bits, no parity, 1 stop bit.

        Host to reader interface shall be TTL level (non-inverted). Both 3.3V and 5V logic levels are allowed. See

         logic levels in section 8.1, Electrical Characteristics.

                                                                                                       Skyetek Inc

                                                                                            1732 Wazee St. Ste 202

                                                                                                 Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                               www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                           Page | 27

11.3     SPI

The SkyeModule Nova provides a simple four-wire SPI host interface. There is also an optional data ready signal to

indicate that the current command is complete and data is available for the host. Figure 11-4 shows an example of

a host interface connection using SPI.

                                                       [PICTURE]

                                         Figure 11-4: SPI Connection Diagram

The protocol for requests to the SkyeModule Nova is outlined below:

        The data packet exchange between the host (SPI Master) and the Nova (SPI Slave) uses SkyeTek Protocol

         v3 (Binary Mode only).  See more about the protocol in section 13, Communicating with the Module.

        The host must implement SPI master functionality.

        The SCK line is the master clock controlled by the host and should remain low during idle state.

        The slave select line is active low.

        The data is setup on the rising edge of SCK.

        The message data is latched on the falling edge of SCK.

        The MOSI signal line provides the data from the host to the SkyeModule Nova.

        Supports data rates up to 4 MBit

        Both 3.3V and 5V logic levels are allowed. See logic levels in section 8.1, Electrical Characteristics.

The timing diagram in Figure 11-5 illustrates this behavior.

                                                       Byte Cycle

              CLK                                                                         10 MHz (max)

              MOSI

              SSEL

              Sampling Points

                                 Figure  11-5:  SPI Request   Setup  and  Sample  Timing

                                                                                                           Skyetek Inc

                                                                                          1732 Wazee St. Ste 202

                                                                                          Denver, CO 80202

Main  720.328.3425  Fax:720.228.2400                                                      www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                              Page | 28

     For the request data on the MOSI line, the host software should keep the SSEL pin at steady state low as

      shown in Figure 11-6 below.

     The time delay Td,MAX between byte cycles in a request should not exceed 5 ms. After 5 ms the

      SkyeModule Nova will timeout, signifying the end of the request.

                                         Request

                                                                          Td,MAX

CLK

MOSI

SSEL

                                         Figure 11-6: SPI Request Timing

                                                                                                     Skyetek Inc

                                                                                  1732 Wazee St. Ste 202

                                                                                  Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                  Page | 29

The protocol for retrieving the response data is outlined below:

     The SkyeModule Nova is half duplex so the response data must be retrieved after the request has been

      sent.

     The GPIO3_DR (data ready) signal will transition high when data is available for the host.

     If data ready is not implemented on the host, the host can poll the module starting 1ms after the

      command send is complete. The module will respond with 0x00 when no data is present, and 0x02 (start

      of frame) when data is available.

     Response data will be thrown away if not read within 10 seconds of becoming available.

     The MISO signal provides the response data from SkyeModule Nova to the host.

     To retrieve data on the MISO line, the SSEL (Slave Select) signal must be low when the clock is sent for an

      entire byte.  Between bytes, SSEL can either stay low or transition high again as long as it transitions

      low before the first clock of the next byte.

     The host can use the data length field (response bytes 2 and 3) in order to determine how many

      bytes to read from the module as these first bytes will always be present immediately following a

      start of frame (0x02).

Figure 11-7 below shows the timing required to retrieve data on the MISO line.

                                                    Response

CLK

MISO

SSEL

GPIO3_DR

                                         Figure 11-7: SPI Response Timing

NOTE – Not reading the entire response before sending another command can cause undesired behavior. Always

make sure to read the entire response when using the SPI interface.

                                                                                                         Skyetek Inc

                                                                                    1732 Wazee St. Ste 202

                                                                                                  Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                        Page | 30

11.4  I2C

The SkyeModule Nova supports can act as an I2C slave device. External pull up resistors are required on the SDA

and SCL lines as shown in Figure 11-8: I2C Connection Diagram. There is also an optional data ready signal to

indicate that the current command is complete and data is available for the host.

                                                [PICTURE]

                                       Figure 11-8: I2C Connection Diagram

The protocol for communicating via I2C is outlined below:

     The I2C interface uses a standard two-wire connection in which SCL is the master clock and SDA is a

      bidirectional serial data line.

     The data packet exchange between the host (I2C Master) and the Nova (I2C Slave) uses SkyeTek Protocol

      v3 (Binary Mode only).  See more about the protocol in section 13, Communicating with the Module.

     I2C fast mode plus (1MHz), I2C fast mode (400 kHz), and 100kHz data rates are all supported.

     The data is sent and received MSB first.

     Up to 5V logic levels are allowed. See logic levels in section 8.1, Electrical Characteristics.

     The device uses a 7-bit address

     The default address = 0x7F, but the address can be changed with the Reader ID system parameter. See

      more about this system parameter in section 14.3.5, Reader ID.

                                                                                                       Skyetek Inc

                                                                                   1732 Wazee St. Ste 202

                                                                                                       Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                     www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                Page | 31

The communication scheme from host to module is as follows:

  Initiate a start condition (SDA transitions low while SCL is high).

  Send the nine bits of the initial start packet as follows:

   o  Send the 7-bit address.

   o  Send a write bit as the eighth bit (0 for writing from the host to the slave).

   o  Send the ninth bit as the “acknowledge” bit (ACK)

   o  If the reader recognizes the address, it pulls SDA low to acknowledge

  Use the bus to clock each byte of the SkyeTek protocol request.

  After sending the entire request, initiate a stop condition. (SCL transitions high, and then SDA transitions

   high while SCL is high)

Wait for command to complete:

  The GPIO3_DR (data ready) signal will transition high when data is available for the host to read.

  If data ready is not implemented on the host, the host can poll the module after the request is sent. The

   module will NAK to a read while it is busy executing a command.

Communication scheme from module to host is as follows:

  Initiate a start condition. (SDA transitions low, and then SCL transitions low.)

  Send the nine bits of the initial start packet as follows:

   o  Send the 7-bit address.

   o  Send a read bit as the eighth bit (1 for reading from the slave to the host).

   o  Send the ninth bit as the “acknowledge” bit (ACK)

   o  If the reader recognizes the address, it pulls SDA low to acknowledge

   o  If the address isn’t recognized or the module is busy the SDA bit will remain high during the ACK

      bit.

  Clock each byte of the SkyeTek protocol response from the module.

  After receiving the response, is received, initiate a stop condition. (SDA transitions high while SCL is high.)

  SDA must transition while the clock is low and remain stable while the clock is high.

  Response data will be thrown away if not read within 10 seconds of becoming available.

Recommended response handler method #1 (polling):

  Read a single byte continuously until the reader ACKs and a 0x02, start of frame is received

  Read two bytes which contain the message length

  Read the remaining message length

Recommended response handler method #2 (using data ready signal):

  Poll on the data ready signal until it transitions high, indicating that data is present

  Read three bytes, the last two contain the message length

  Read the remaining message length

                                                                                                       Skyetek Inc

                                                                                             1732 Wazee St. Ste 202

                                                                                             Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                           www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                       Page | 32

A timing diagram illustrating the I2C data transfer is shown in the figure below:

SCL

            1-7                     8    9    1-8                    9             1-8         9

SDA

            7-bit Address           R/W  ACK  8-bit Data             ACK           8-bit Data  ACK/NACK

     Start                                                                                                    Stop

                                         Figure 11-9: I2C Timing Diagram

NOTE – Not reading the entire response before sending another command can          cause undesired behavior.  Always

make sure to read the entire response when using the I2C interface.

                                                                                                  Skyetek Inc

                                                                                        1732 Wazee St. Ste 202

                                                                                               Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                             www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                    Page | 33

12  SkyeModule Nova Antenna Options

The SkyeModule Nova has 2 antenna ports to connect external antennas. The ports use an Ultra Miniature

Connector (U.FL) to save space and cost. Any 50 ohm antenna in the appropriate f requency band (865-

868MHz for Europe, 920-928MHz for North America) can be used with the Nova.

The SkyeModule Nova also uses an advanced Adaptive Antenna Tuning circuit to ensure a quality impedance

match with any antenna. The user can take advantage of this feature by first attaching the antenna to the

port they would like to use, then sending a SkyeTek Protocol command to the Nova for it to execute its tuning

sequence. The Nova will measure the reflected power caused by impedance mismatch and then will

automatically compensate, delivering the maximum power to the antenna while reducing noise in the

system.

NOTE – Read range depends on antenna choice and operating environment. Range can vary widely, depending on

your choice of tag inlay and antenna gain. See section 9.2, Range Specifications for expected range performance

with different antennas.

                                                                                                   Skyetek Inc

                                                                             1732 Wazee St. Ste 202

                                                                             Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                           www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                              Page | 34

13    Communicating with the Module

13.1   Host Communication (SkyeTek Protocol v3)

The SkyeModule Nova operates under control of a host according to SkyeTek Protocol v3. The basic

command and response formats are illustrated for your reference in the following two sections 13.2 and

13.3. The best way to get started creating and understanding commands is to follow the application

notes below while using the Protocol Builder in SkyeWare v4:

      Nova Basic Tag Commands – Guides you through the select tag, read tag and write tag commands.

      SkyeTek Protocol v3 Reader Commands – Explains how to read and write system parameters.

For more feature specific commands, use the tag specific application notes listed in the Additional

Reading section 1.3.

For a quick reference on the protocol if you already know the command you want to use, see the SkyeTek

Protocol v3 Reference Guide.  This provides detailed information on each command structure, error

codes, and tags types.  Be warned that this document is very length as it details every command

available for every SkyeTek module.

13.2   Request Formats

Flags  Cmd.   Tag             TID   TID    Addr.     # of     Data            Data      CRC

              Type            Len.                   Blks.    Len.

4      4      4               4     32     4         4        4               2K        4

                                    (max)

                                   Table 13-1: Request Format (bytes), ASCII Mode

Msg    Flags  Cmd.            Tag    TID   TID    Addr.       # of       Data       Data     CRC

.                             Type   Len.                     Blks.      Len.

Len.
2      2      2               2      1     32     2           2          2          1K       2

                                           (max)

                                   Table 13-2: Request Format (bytes), Binary Mode

                              Required Fields (must be present at all times)

                              Optional fields (depending on the command and flags)

                              Required fields, depending on the command

                                                                                                     Skyetek Inc

                                                                                           1732 Wazee St. Ste 202

                                                                                             Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                           www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                Page | 35

13.3  Response Formats

Message  Response Code                   Tag Type  Data Length          Response  CRC

Length                                                                  Data

2        2                               2         2                    1K        2

                        Table 13-3: Response Format (bytes), Binary Mode

                        Required Fields (must be present at all times)

                        Optional fields (depending on the command and flags)

                        Required fields, depending on the command

                                                                                       Skyetek Inc

                                                                                  1732 Wazee St. Ste 202

                                                                                  Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                            Page | 36

14    System Parameters

14.1  System Parameter Summary

System parameters let you configure reader settings to customize the reader for your environment. You

can temporarily alter parameters in memory or change the default values that are stored on the

SkyeModule Nova’s non-volatile memory. The following table summarizes the parameters. (See System

Parameter Detail in section 14.3 for detailed information about each parameter)

                                    Address  Num.    Read

Parameter Name                      (hex)    Blocks  /Writ  Default Value

                                             (hex)   e

Serial Number                       0x0000   0x0004  R      0x00000000

Firmware Version                    0x0001   0x0004  R      0xXXXXXXXX (depending on release)

Hardware Version                    0x0002   0x0004  R      0xXXXXXXXX (depending on release)

Product Code                        0x0003   0x0002  R      0x0010

Reader ID                           0x0004   0x0004  R/W    0xFFFFFFFF

Reader Name                         0x0005   0x0032  R/W    SkyeModule Nova (in ASCII Format)

Host Interface Type                 0x0006   0x0001  R/W    0x01 (TTL)

Interface Baud Rate                 0x0007   0x0001  R/W    0x02 (38400)

User Port Direction                 0x0008   0x0001  R/W    0x00

User Port Value                     0x0009   0x0001  R/W    0x0F

MUX Control                         0x000A   0x0001  R/W    0x00

Operating Mode                      0x000C   0x0001  W      N/A

Tag Command Retries                 0x0011   0x0001  R/W    0x03

Power Level                         0x0012   0x0001  R/W    0xDC (27 dBm)

Current Frequency                   0x0004   0x0004  R/W    0x3689CAC0 (915 MHz)

Start Frequency                     0x0031   0x0004  R/W    0x35C80160 (902.3 MHz)

Stop Frequency                      0x0032   0x0004  R/W    0x374B9420 (927.7 MHz)

Hop Channel Spacing                 0x0034   0x0004  R/W    0x00030D40 (200 KHz)

Frequency Hopping                   0x0035   0x0001  R/W    0x01 (pseudo-random)

Sequence

Modulation Depth                    0x0036   0x0001  R/W    0x64 (100%)

Regulatory Mode                     0x0037   0x0001  R/W    0x00

                         Table 14-1: SkyeModule Nova System Parameters

                                                                                                Skyetek Inc

                                                                                 1732 Wazee St. Ste 202

                                                                                 Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                               www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                 Page | 37

14.2    Changing System Parameters

        CAUTION – Changing system parameter values – especially the default values – can render your

        SkyeModule Nova non-operational in your environment. Research, record, and test all planned

        changes to make sure they are compatible with your system.

You can read or write system parameters via the following commands:

       Read System Parameter – Reads the current value of the system parameter at the memory address

        specified.

       Write System Parameter – Writes a new value to the system parameter at the memory address specified.

       Store Default System Parameter – Writes a new system parameter value to the non-volatile memory. This

        saves the setting even after a power cycle or reset.

       Retrieve Default System Parameter – Reads the system parameter value at the address specified out of

        non-volatile memory.

See System Parameter Detail in section 14.3 for detailed information about individual parameters.

For full examples of how to use these commands, see the system parameter examples found in the Using

SkyeProtocol V3 Reader Commands application note.

        CAUTION – Resetting (cycling power) on your SkyeModule Nova causes all system parameters to

        revert to their default values. Any changes made to system parameters in memory are lost at reset

        unless you write them to the non-volatile memory as the new default values. Any changes to the

        default values do not take effect until the reader is reset.

14.3    System Parameter Details

This section describes the SkyeModule Nova system parameters.

14.3.1  Serial Number

       Returns the serial number of the reader

       Parameter address: 0x0000

       Length (bytes): 4

       Default value: 0x00000000

       Read-only

14.3.2  Firmware Version

       Returns the firmware version currently loaded on the reader. (Refer to the SkyeModule Nova

        Release Notes for more information about the specific firmware release.)

       Refer to the SkyeWare User Guide for information about updating firmware.

                                                                                                      Skyetek Inc

                                                                                   1732 Wazee St. Ste 202

                                                                                                   Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                 www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                 Page | 38

       Parameter address: 0x0001

       Length (bytes): 4

       Default value: 0xXXXXXXXX (depending on release)

       The firmware version uses this format:

        o  Major revision (1 Byte)

        o  Minor revision (1 Byte)

        o  Current build number (2 bytes)

       Read-only

14.3.3  Hardware Version

       Returns the current hardware version of the reader

       Parameter address: 0x0002

       Length (bytes): 4

       Default value: 0xXXXXXXXX (depending on release)

       The hardware version uses the following format:

        o  Major revision (1 Byte)

        o  Minor revision (1 Byte)

        o  Current build number (2 bytes)

       Read-only

14.3.4  Product Code

       Returns the SkyeTek product code identifier. (Each SkyeTek Product has a unique product code.)

       Parameter address: 0x0003

       Length (bytes): 2

       Default value: 0x0010

       Read-only

14.3.5  Reader ID

       This was used for a deprecated SkyeTek protocol feature. It is now used as the I2C address of the reader

        in I2C mode. The least significant 7 bits of the reader ID act as the 7-bit I2C address.

       Example: A value of 0x0000001B would indicate an I2C address of 0x1B

       Parameter address: 0x0004

       Length (bytes): 4

       Default value: 0xFFFFFFFF

       Read/write

14.3.6  Reader Name

       Identifies a reader with a 32-byte user-defined name.

                                                                                                        Skyetek Inc

                                                                                                  1732 Wazee St. Ste 202

                                                                                                  Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                   Page | 39

       Parameter address: 0x0005

       Length (bytes): 32 (20 hex)

       Default value is “SkyeModule Nova” (in hex)

       Read/write

14.3.7  Host Interface Type

       Identifier for the type of host interface being used.

       Parameter address: 0x0006

       Length (bytes): 1

       Default value: 0x01 (TTL Serial)

       Valid host interface values are:

        o  0x01 – TTL Serial

        o  0x03 – SPI

        o  0x05 – I2C

        o  0x06 – USB

        o  Any other values are invalid and are ignored.

       Read/write

14.3.8  Interface Baud Rate

       Sets the baud rate of the host interface.

       Works for the TTL Serial host interface only.

       Parameter address: 0x0007

       Length (bytes): 1

       Default value: 0x02 (38,400)

       Valid baud rate values are:

        o  0x01 – 19200

        o  0x02 – 38400

        o  0x03 – 57600

        o  0x04 – 115200

        o  0x05 – 1 MBaud

        o  Any other value – 9600

       Read/write

14.3.9  User Port Direction

       Sets the direction of the GPIO pins of the reader.

       Parameter address: 0x0008

       Length (bytes): 1

       Default value: 0x00

       Default value is 0x00 (GPIO pins are outputs).

       A one in the bit position indicates that the corresponding GPIO pin is an input.

                                                                                          Skyetek Inc

                                                                                          1732 Wazee St. Ste 202

                                                                                          Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                        www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                      Page | 40

        A zero in the bit position indicates that the corresponding GPIO pin is an output.

        Bits correspond to the pins as follows:

         o  BIT0 – GPIO 0

         o  BIT1 – GPIO 1

         o  BIT2 – GPIO 2

         o  BIT3 – GPIO 3

         o  BIT4 - BIT7 – Reserved

        Read/write

14.3.10  User Port Value

        Sets or reads the value of the GPIO pins of the reader.

        Parameter address: 0x0009

        Length (bytes): 1

        Default value is 0x0F (GPIO pins are logic high).

        A one in the bit position indicates that the corresponding GPIO pin is logic high.

        A zero in the bit position indicates that the corresponding GPIO pin is logic low.

        Bits correspond to the pins as follows:

         o  BIT0 – GPIO 0

         o  BIT1 – GPIO 1

         o  BIT2 – GPIO 2

         o  BIT3 – GPIO 3

         o  BIT4 - BIT7 – Reserved

        Read/write

14.3.11  Operating Mode

        Can put the reader into sleep mode or into keyboard wedge mode.

        Parameter address: 0x000C

        Length (bytes): 1

        Default value is 0x00 (active).

        Writing a value 0x01 to this system parameter puts the reader in sleep mode.

        Sending a single byte on the interface that put the reader to sleep wakes the reader from sleep mode.

        NOTE: SOFTWARE SLEEP MODE DOES NOT FUNCTION IN USB COMMUNICATIONS. This is planned for

         future firmware releases.

        Write Only

14.3.12  Tag Command Retries

        Sets the number of times a tag command will be retried internally.

        Parameter address: 0x0011

        Length (bytes): 1

        Default value is 0x03

                                                                                             Skyetek Inc

                                                                                             1732 Wazee St. Ste 202

                                                                                             Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                           www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                   Page | 41

      In very time dependent applications, it is recommended to set this parameter to 0 as this removes much

       of the variability of response time.

      In most situations, a retry number of 3 is sufficient.

      Read/write

      WARNING: Setting this parameter too high can cause very long response times when there is no tag or a

       failing tag in the field.

14.3.13 Power Level

      Configures the power level for the reader.

      Parameter address: 0x0012

      Length (bytes): 1

      Default value: 0xDC (27 dBm)

      Power level is set in steps of 0.1 dB from 10 dBm to 27 dBm.

      Power levels are written in hex corresponding to a decimal value between 50 and 220 (see Table 14-10).

      Use the following equation to calculate the value to be written for a desired power level:

       (Desired power in dBm – 5)/0.1 = decimal value to write to system parameter

                                     Table 14-2: Common Power Values

                                     SkyeTek Decimal Value

Power (dBm)                                                                Hex Equivalent

10                                   50                                    0x32

12                                   70                                    0x46

15                                   100                                   0x64

17                                   120                                   0x78

20                                   150                                   0x96

21                                   160                                   0xA0

24                                   190                                   0xBE

27                                   220                                   0xDC

      Read/write

NOTE – SkyeModule Nova’s shipped with the SkyeTek Development Kit are preset to a power level of 27 dBm.

14.3.14 Current Frequency

      Sets the current frequency with which the reader singulates a tag.

      Parameter address: 0x0030

      Length (bytes): 4

      Default value: 0x3689CAC0 (915 MHz)

                                                                                                   Skyetek Inc

                                                                                    1732 Wazee St. Ste 202

                                                                                                   Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                                 www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                        Page | 42

        This parameter is a 4-byte hex equivalent of the frequency. Table 14-11 shows hex values for commonly

         used frequencies.

        Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

14.3.15  Start Frequency

        Sets the low end of the frequency range under which the reader operates.

        Parameter address: 0x0031

        Length (bytes): 4

        Default value: 0x35C80160 (902.3 MHz)

        This parameter is written with a 4-byte hex equivalent of the frequency desired. See Table 14-11 for

         commonly used frequencies and their hex values.

        To enable frequency hopping, set a frequency range using the Start Frequency and Stop Frequency system

         parameters. Then use the Frequency Hopping Sequence parameter to set the frequency hopping mode

         (either sequential or pseudo-random). To disable frequency hopping, set the Start Frequency and Stop

         Frequency parameter to the same value.

        Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

                                                                                   Skyetek Inc

                                                                                   1732 Wazee St. Ste 202

                                                                                   Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                 www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                      Page | 43

14.3.16 Stop Frequency

      Sets the high end of the frequency range under which the reader operates.

      The parameter address: 0x0032

      Length (bytes): 4

      Default value: 0x374B9420 (927.7 MHz)

      This parameter is written with a 4-byte hex equivalent of the frequency desired. See table 14-11 for

       commonly used frequencies and their hex values.

      To enable frequency hopping, set a frequency range using the Start Frequency and Stop Frequency system

       parameters. Then use the Frequency Hopping Sequence parameter to set the frequency hopping mode

       (either sequential or pseudo-random). To disable frequency hopping, set the Start Frequency and Stop

       Frequency parameter to the same value.

      Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

                                    Table 14-3: Commonly Used Frequencies

Frequency (MHz)                       Hex Equivalent                       Description

865.7                                 0x339988A0                           EU Start

866.7                                 0x33A8CAE0                           EU Center

867.9                                 0x33BB1A60                           EU Stop

902.3                                 0x35C80160                           NA Start

915.0                                 0x3689CAC0                           NA Center

927.7                                 0x374B9420                           NA Stop

                                                                                        Skyetek Inc

                                                                                        1732 Wazee St. Ste 202

                                                                                        Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                      www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                  Page | 44

14.3.17 Hop Channel Spacing

  Controls the hop channel spacing when frequency hopping is enabled.

  Parameter address: 0x0034

  Length (bytes): 4

  Default value: 0x00030D40 (200 KHz)

  To enable frequency hopping, set a frequency range using the Start Frequency and Stop Frequency system

   parameters. Then use the Frequency Hopping Sequence parameter to set the frequency hopping mode

   (either sequential or pseudo-random). To disable frequency hopping, set the Start Frequency and Stop

   Frequency parameter to the same value.

  Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

14.3.18 Frequency Hopping Sequence

  Switches the hopping sequence between pseudo-random and sequential mode.

  Parameter address: 0x0035

  Length (bytes): 1

  Default value: 0x01 (pseudo-random)

  To set the reader to sequential hopping mode, write 0x00 to this parameter.

  To reset the reader to pseudo-random hopping sequence, write 0x01 to this parameter.

  To enable frequency hopping, set a frequency range using the Start Frequency and Stop Frequency system

   parameters. Then use the Frequency Hopping Sequence parameter to set the frequency hopping mode

   (either sequential or pseudo-random). To disable frequency hopping, set the Start Frequency and Stop

   Frequency parameter to the same value.

  Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

                                                                                         Skyetek Inc

                                                                                1732 Wazee St. Ste 202

                                                                                         Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                       www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                        Page | 45

14.3.19  Modulation Depth

        Sets the modulation depth of the reader-to-tag transmissions, as calculated by the equation: (Vmax –

         Vmin)/Vmax

        Parameter address: 0x0036

        Length (bytes): 1

        Default value: 100%

        The values for the modulation depths are in steps of 10, ranging from 10% to 100%.

        The values are the hex equivalent of the corresponding modulation depth.

                              Table 14-4: Common Modulation Depth Values

Modulation Depth (%)

                                              Hex Equivalent

30                                            0x1E

80                                            0x50

90                                            0x5A

100                                           0x64

        The modulation depth is calculated by the reader using the equation:

         (VMAX – VMIN)/VMAX where VMAX is the RF voltage when transmit power is maximum and VMIN is the RF

         voltage when the transmit power is minimum. (For 100% modulation depth, VMIN equals zero.)

        See the manufacturer’s tag data sheet for the modulation depth supported for the tags in your

         application.

        Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

                                                                                                        Skyetek Inc

                                                                                             1732 Wazee St. Ste 202

                                                                                             Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                           www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                            Page | 46

14.3.20 Regulatory Mode

         Enables pulse shaping, listen before talk, and timing modifications for regions with special regulatory

          requirements, such as Europe.

         Parameter address: 0x0037

         Length (bytes): 1

         Default value 0x00 (no pulse shaping)

         Read/write

NOTE – See “Error! Reference source not found.” on page Error! Bookmark not defined. to view compliance

information and recommended reader settings.

                                         Table 14-5: Regulatory Mode Values

Mode                                                                          Hex Value

No pulse shaping—Australia/New Zealand, Hong Kong, North America, Singapore,  0x00

Taiwan

ETSI/Europe                                                                   0x01

Not used                                                                      0x02

Not used                                                                      0x03

Korea                                                                         0x04

                                                                                         Skyetek Inc

                                                                              1732 Wazee St. Ste 202

                                                                                    Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                  www.skyetek.com
SkyeModule Nova Datasheet - Preliminary                                                                              Page | 47

15    Special Features

15.1  Sleep Modes

The Nova has two low power sleep modes: deep sleep (hardware controlled) and software sleep mode. The deep

sleep mode has the lowest power consumption but a longer wake time. It can only be set using the N_DEEP_SLEEP

pin 20 of the host interface connector. There is an internal pull-up on this pin, so if it is unused it can be left

floating. To put the reader into deep sleep, set this pin low. Software sleep mode can be set using the Operating

Mode system parameter. See the System Parameters section 14 for details. Current consumption and wake times

for both modes can be found in the Electrical Characteristics section 8.1 and Error! Reference source not found.

section Error! Reference source not found., respectively.

NOTE: SOFTWARE SLEEP MODE DOES NOT WORK IN USB COMMUNICATIONS. This is planned for future

firmware releases.

15.2  Feature Requests

Request a feature for the Nova module on the SkyeTek support page at support.skyetek.com!

                                                                                           Skyetek Inc

                                                                                           1732 Wazee St. Ste 202

                                                                                           Denver, CO 80202

Main 720.328.3425 Fax:720.228.2400                                                         www.skyetek.com
This datasheet has been downloaded from:

datasheet.eeworld.com.cn

Free Download

Daily Updated Database

100% Free Datasheet Search Site

100% Free IC Replacement Search Site

Convenient Electronic Dictionary

Fast Search System

www.EEworld.com.cn

All Datasheets Cannot Be Modified Without Permission

               Copyright © Each Manufacturing Company
小广播