EMI Gaskets, Sheets & Absorbers 0.75in Width GS8000 Adh 1MTR =1PC

参数
产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Gore
产品种类:
Product Category:
EMI Gaskets, Sheets & Absorbers
RoHS:YES
产品类型:
Product Type:
EMI Gaskets, Sheets & Absorbers
产品:
Product:
Gaskets
类型:
Type:
EMI Gaskets
安装风格:
Mounting Style:
Adhesive PSA Conductive
宽度:
Width:
0.75 in
系列:
Series:
GS8000
封装:
Packaging:
Cut Tape
封装:
Packaging:
MouseReel
封装:
Packaging:
Reel
商标:
Brand:
Gore
工厂包装数量:
Factory Pack Quantity:
15
子类别:
Subcategory:
EMI/RFI

EDR-80-03X-0750-SC器件文档内容

GORE® EMI Shielding                                                            GS8000 SERIES — Gaskets

                                                                    SOLUTIONS                                and Grounding Pads

Increase package design flexibility while maintaining

electrical integrity

The GS8000 Series of GORE® EMI Shielding Solutions improves

package design flexibility without compromising the electrical

performance of the device. Their extended service heights enable

these highly compressible materials to maintain consistent

conductivity through a wide range of gaps (see Figure 1 and Figure

2). With Gore’s strong technology focus in materials, the GS8000

Series was developed with a unique conductive foam. The soft

conductive-foam construction accommodates surface variations in

covers and printed circuit boards, alleviating the need to specify

very tight tolerances. This soft construction also makes the GS8000

Series compatible with plastic housings and snap fasteners. This

material maintains excellent shielding performance in a trace

width as narrow as one millimeter, providing comparable

performance to other EMI shielding materials that are three times the    Benefits of GORE® EMI Shielding

width. With the lower compression or closure force, fewer fasteners      Solutions — GS8000 Series

are needed.

                                                                         • Unsurpassed shielding effectiveness and minimal DC

Table 1: Environmental and Mechanical Properties                         resistance with low compressive force and broad range

                                                                         of tolerance take-up

Property                                                 Value           • Reliable electrical performance over wide range of gap

Temperature range                               - 45°C to 85°C           distances from soft foam construction

RoHS Status (lead, cadmium,                                              • Effective shielding performance in trace widths as

hexavalent chromium, mercury, bromine)                   Pass            narrow as one millimeter

Flammability in accordance with UL 94                                    • Improved design flexibility because of low closure force

horizontal burn method                                   Pass

Halogen levels (measured per BS EN 14582:2007)                           Available as grounding pads and precision die-cut parts that

Chlorine                                        < 50 ppm

Bromine                                         < 50 ppm                 enable precise, high-volume assembly, the GS8000 Series of

Fluorine                                        < 50 ppm                 GORE® EMI Shielding Solutions provide maximum cavity-to-cavity

Iodine                                          < 50 ppm                 EMI protection in a smaller size for more design flexibility.

Typical working range (for grounding pads)      0.15 mm to 2.2 mm

                                                ( 0.006 in to 0.087 in)  Available as custom die-cut gaskets, strip gaskets, and grounding pads

Typical working range (for EMI gaskets)         0.15 mm to 1.4 mm

                                                ( 0.006 in to 0.055 in)

Typical pressure to recommended                 5 to 30 psi

compression stop (RCS)

Typical Applications

• Portable electronic devices, mobile phones, and GPS

• Portable computers

• Hand-held field testing equipment

                                                                         Covered by patent No. US 6,309,742
   GORE® EMI Shielding

                                                              SOLUTIONS

Extended Service Heights                                                       Figure 1: Recommended Service Heights for Use

The GS8000 Series of GORE® EMI Shielding Solutions performs well               in EMI Gasket Applications

in both grounding and EMI shielding applications (Table 3). Gore

recommends using each variant within a range of service heights                                   1.50                                                                 1.40 mm @ 5 psi

(gap distances). For shielding applications, Gore recommends a                                    1.35

smaller service height range than for grounding applications to                                   1.20

ensure a robust EMI seal.                                                      Gap Distance (mm)  1.05

                                                                                                  0.90                                           0.85 mm @ 20 psi

The low closure force and broad range of tolerance take-up results in                             0.75

multiple product choices for some gap distances. Selecting the most                                                        0.60 mm @ 15 psi

suitable variant for a given application depends on the following:                                0.60

                                                                                                        0.45 mm @ 25 psi                                               0.60 mm @ 75 psi

                                                                                                  0.45                                           0.50 mm @ 100 psi

•  Gap distance of the housing that needs to be filled                                             0.30

•  Compression force required to achieve the specified gap distance                                0.15                     0.30 mm @ 95 psi

•  Required DC resistance for grounding applications (or required                                 0.00  0.15 mm @ 300 psi

   shielding effectiveness for shielding applications) at a specified                                    GS8000-03A         GS8000-063            GS8000-095            GS8000-126

   gap distance                                                                                                            GS8000                Series

Figure 1 and Figure 2 show recommended service heights (gap

distances) for each variant.

                                                                               Figure 2: Recommended Service Heights for Use

Pressure and DC Resistance                                                     in Grounding Pads

Four variants of the GS8000 Series provide conductivity when

compressed to 0.6 mm (0.024 in); however, the amount of pressure                                  2.40                                                                 2.20 mm @ 1 psi

                                                                                                  2.25

and DC resistance varies for each. Table 2 shows the values for each                              2.10

of these four variants.                                                                           1.95

                                                                               Gap Distance (mm)  1.80

                                                                                                  1.65

Table 2: Pressure and DC Resistance Values                                                        1.50                                                                          1.40 mm

                                                                                                  1.35                                           1.20 mm @ 5 psi                @ 5 psi

at 0.6 mm Gap (data taken from Figures 3 – 6)                                                     1.20

                                                                                                  1.05                     0.90 mm @ 5 psi

                                                                                                  0.90                                                       0.85 mm

   Variants      Pressure Required psi (kPa)   DC Resistance (ohms)                               0.75  0.6 mm @ 7 psi                                       @ 20 psi

                                                                                                  0.60                     0.60 mm

                                                                                                  0.45  0.38 mm @29 psi    @ 15 psi                                    0.60 mm @ 75 psi

   GS8000-03A                 7 (48)                   0.125                                      0.30                                           0.50 mm @ 100 psi

   GS8000-063              15 (103)                    0.03                                       0.15                     0.30 mm @ 95 psi

                                                                                                  0.00  0.15 mm @ 300 psi

   GS8000-095              55 (379)                    0.02                                             GS8000-03A         GS8000-063            GS8000-095            GS8000-126

   GS8000-126              75 (517)                    0.01                                                                GS8000 Series

Table 3: Product Typical Performance (measured on 5 x 5 mm grounding pads)

                                              Compression Stop                                    Pressure to Achieve                            Initial DC            Recovered

   Variants              Weight                                                                         Compression                              Resistance            Thickness
                                                   mm (in)                                                                                                             mm (in)*
                         (g)                                                                            psi (kPa)                                (ohms)

                                      High                       0.60 (0.024)                           7 (48)                                   0.125                 0.70     (0.028)

   GS8000-03A            0.008        Recommended                0.38 (0.015)                           29 (200)                                 0.027                 0.51     (0.020)

                                      Low                        0.15 (0.006)                           300 (2067)                               0.004                 0.21     (0.008)

                                      High                       0.90 (0.035)                           5 (34)                                   0.070                 1.19     (0.047)

   GS8000-063            0.010        Recommended                0.60 (0.024)                           15 (103)                                 0.025                 0.91     (0.036)

                                      Low                        0.30 (0.012)                           95 (655)                                 0.007                 0.51     (0.020)

                                      High                       1.20 (0.047)                           5 (34)                                   0.115                 1.65     (0.065)

   GS8000-095            0.011        Recommended                0.85 (0.033)                           20 (138)                                 0.040                 1.24     (0.049)

                                      Low                        0.50 (0.020)                           100 (689)                                0.010                 0.74     (0.029)

                                      High                       2.20 (0.087)                           1 (6.9)                                  0.240                 2.62     (0.103)

   GS8000-126            0.013        Recommended                1.40 (0.055)                           5 (34)                                   0.150                 1.90     (0.075)

                                      Low                        0.60 (0.024)                           75 (517)                                 0.012                 0.94     (0.037)

*  To measure the recovered thickness, samples were compressed to the compression stop. While compressed, the samples were subjected to a 70°C temperature         soak for 70  hrs per ASTM

   D395B. Lastly, the samples were released from compression and allowed to recover for 30 minutes before the recovered thickness was measured.

                                                                       Page 2
When using the GS8000 Series as an EMI gasketing material, Gore              Force Displacement Resistance

recommends a smaller service height range to ensure an effective EMI         The GS8000 Series requires compression in order to achieve an

seal. We recommend compressing the GS8000 gasket material to at              electrical pathway. They provide conductivity on contact; however, the

least the recommended compression stop (Table 4).                            amount of force and DC resistance differs for each variant (Figures 3–6).

Table 4: Shielding Effectiveness1                                            Figure 3: GS8000-03A Force Displacement Resistance

                                                                             (testing with 5 x 5 mm grounding pads)

                  Recommended         Pressure

Variants          Compression Stop    to Achieve   Shielding                                            0.25                                                                    350

                        mm (in)       Compression  Effectiveness1

                                      psi (kPa)                                                                                                                                 300

                  High  0.45 (0.018)  25 (172)     > 90 dB                                              0.20

GS8000-03A                                                                           Resistance (Ohms)                                                                          250          Pressure (psi)

                  Low   0.15 (0.006)  300 (2067)   > 100 dB                                             0.15

                  High  0.60 (0.024)  15 (103)     > 90 dB                                                                                                                      200

GS8000-063                                                                                              0.10                                                                    150

                  Low   0.30 (0.012)  95 (655)     > 100 dB

                  High  0.85 (0.033)  20 (138)     > 85 dB                                                                                                                      100

GS8000-095                                                                           DC                 0.05

                  Low   0.50 (0.020)  100 (689)    > 95 dB                                                                                                                      50

                  High  1.40 (0.055)  5 (34)       > 75 dB                                              0.00                                                                    0

GS8000-126                                                                           mm 0.60                         0.55   0.50   0.45   0.40   0.35   0.30   0.25   0.20     0.15 mm

                  Low   0.60 (0.024)  75 (517)     > 95 dB

                                                                                     in                     0.024    0.022  0.020  0.018  0.016  0.014  0.012  0.010  0.008    0.006     in

1 All measurements made using ARP-1705 modified test method through 3 GHz on                                                             Compressed Gap                Pressure

2 mm trace width                                                                                                                                                      Resistance

                                                                             Figure 4: GS8000-063 Force Displacement Resistance

                                                                             (testing with 5 x 5 mm grounding pads)

                                                                                                        0.25                                                                    350

                                                                                                                                                                                300

                                                                                                        0.20

                                                                                     Resistance (Ohms)                                                                          250      Pressure (psi)

                                                                                                        0.15                                                                    200

                                                                                                        0.10                                                                    150

                                                                                                                                                                                100

                                                                                     DC                 0.05

                                                                                                                                                                                50

                                                                                                        0.00                                                                    0

                                                                                                        mm    0.9           0.8    0.7    0.6           0.5    0.4             0.3 mm

                                                                                                        in    0.035        0.031   0.028  0.024         0.020  0.016           0.012 in

                                                                                                                                        Compressed Gap               Pressure

                                                                                                                                                                     DC Resistance

                                                                             Page 3
                      GORE® EMI Shielding

                                                                                 SOLUTIONS

Figure 5: GS8000-095 Force Displacement Resistance                                                                   Ordering Information

(testing with 5 x 5 mm grounding pads)                                                                               The GS8000 Series of GORE® EMI Shielding Solutions

                                                                                                                     available as custom die-cut gaskets, strip gaskets, and

                      0.25                                                                 350                       grounding pads. To order or specify GS8000 Series grounding

                                                                                           300                       pads and custom die-cut gaskets, contact Gore for assistance.

                      0.20

DC Resistance (Ohms)                                                                       250       Pressure (psi)  Standard strip gaskets (Table 5) are available through

                      0.15                                                                 200                       several distributors. Go to gore.com/emidistributors for the

                                                                                                                     list. These strip gaskets are packaged on 15-meter rolls.

                      0.10                                                                 150                       For other available strip gasket configurations, contact Gore

                                                                                           100                       for assistance.

                      0.05

                                                                                           50                        Table 5: Strip Gasket Ordering Information

                      0.00                                                                 0                         Part Number                         Variants                                    Width

                      mm    1.2  1.1    1.0         0.9         0.8       0.7    0.6       0.5 mm

                      in  0.047  0.043  0.039  0.035            0.031     0.028  0.024     0.020 in                  EDR-80-03A-0500-SC                  GS8000-03A                                  0.500 in

                                               Compressed Gap                    Pressure                            EDR-80-03A-0250-SC                  GS8000-03A                                  0.250 in

                                                                                 DC Resistance

                                                                                                                     EDR-80-03A-0125-SC                  GS8000-03A                                  0.125 in

                                                                                                                     EDR-80-063-0500-SC                  GS8000-063                                  0.500 in

Figure 6: GS8000-126 Force Displacement Resistance                                                                   EDR-80-063-0250-SC                  GS8000-063                                  0.250 in

(testing with 5 x 5 mm grounding pads)                                                                               EDR-80-063-0125-SC                  GS8000-063                                  0.125 in

                      0.25                                                                 350                       EDR-80-095-0500-SC                  GS8000-095                                  0.500 in

                                                                                                                     EDR-80-095-0250-SC                  GS8000-095                                  0.250 in

                                                                                           300                       EDR-80-095-0125-SC                  GS8000-095                                  0.125 in

                      0.20

DC Resistance (Ohms)                                                                       250       Pressure (psi)  EDR-80-126-0500-SC                  GS8000-126                                  0.500 in

                      0.15                                                                 200                       EDR-80-126-0250-SC                  GS8000-126                                  0.250 in

                                                                                                                     EDR-80-126-0125-SC                  GS8000-126                                  0.125 in

                      0.10                                                                 150

                                                                                           100

                      0.05

                                                                                           50

                      0.00                                                                 0

                      mm    2.2  2.0    1.8    1.6       1.4         1.2  1.0    0.8       0.6 mm

                      in  0.087  0.079  0.071  0.063     0.055  0.047     0.039  0.031     0.024 in

                                               Compressed Gap                    Pressure

                                                                                 DC Resistance

                                                                                                                     Covered by patent No. US 6,309,742

                                                                                                                     NOTICE — USE RESTRICTIONS APPLY

                                                                                                                     Not for use in food, drug, cosmetic or medical device

                                                                                                                     manufacturing, processing, or packaging operations.

W. L. Gore & Associates                                                                              GORE and designs are trademarks of W. L. Gore & Associates ©2015 W. L. Gore & Associates, Inc.  MAT-0128-R3-DAT-US-JUN16

gore.com

                                                                                                     Page 4
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Gore:

EDR-80-095-0750-SC      EDR-80-126-0375-SC  EDR-80-063-0250-SC   EDR-80-03X-0375-SC   EDR-80-095-0125-SC

EDR-80-095-0500-SC   EDR-80-063-0750-SC     EDR-80-095-0375-SC  EDR-80-126-0500-SC   EDR-80-063-0125-SC

EDR-80-063-0375-SC   EDR-80-03X-0125-SC     EDR-80-03X-0500-SC   EDR-80-126-0250-SC  EDR-80-03X-0750-SC

EDR-80-095-1000-SC   EDR-80-126-1000-SC     EDR-80-126-0750-SC  EDR-80-063-0500-SC   EDR-80-126-0125-SC

EDR-80-095-0250-SC   EDR-80-03X-1000-SC     EDR-80-03X-0250-SC   EDR-80-063-1000-SC  EDR-80--03A-1000-SC

EDR-80--03A-0125-SC  EDR-80--03A-0500-SC    EDR-80--03A-0250-SC  EDR-80--03A-0750-SC  EDR-80--03A-0375-

SC
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved