电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

E5ZN-2CP03TC-309 24VDC

器件型号:E5ZN-2CP03TC-309 24VDC
器件类别:机电产品    工业自动化    控制器   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

控制器 GTC Thermo Input Ana log Outpt

参数
产品属性属性值
制造商:Omron
产品种类:控制器
发货限制:Mouser目前不销售该产品。
RoHS:详细信息
商标:Omron Automation and Safety
产品类型:Controllers
工厂包装数量:1
子类别:Controllers
零件号别名:E5ZN2CP03TC30924VDC
单位重量:100 g

E5ZN-2CP03TC-309 24VDC器件文档内容

    Modular Temperature Controller

    E5ZN

                                                                                                                            CSM_E5ZN_DS_E_3_1

New DIN Track Mounting Temperature

Controller

• Two channels of temperature control available despite width of

only 22.5 mm.

• The Temperature Controller itself can be replaced without

changing terminal wiring.

• Use in combination with a compact Setting Display Unit to

reduce communications programming requirements.

• Front-panel LED indicators for easy operation monitoring.

• Power supply and communications wiring not required between

Units when mounted side-by-side.

• CompoWay/F communications protocol supported.

• UL, CSA, and CE Marking compliance.

          Refer to Safety Precautions on page 11 to 12 and Safety

          Precautions for All Temperature Controllers.

Model Number Structure

■ Model Number Legend

E5ZN-@@@@@@-@

            1  2  3     4  5  6  7

1.  Control points                                                 4.  Option

    2:      Two points                                                 H:      Heater burnout alarm

2.  Control output                                                     F:      Transfer output (See note 1.)

    Q:      Voltage (for driving SSR)                              5.  Communications

    T:      Transistor                                                 03:     RS-485

    C:      Current                                                6.  Input type

3.  Auxiliary output                                                   TC:     Thermocouple

    P:      Two sourcing transistor outputs                            P:      Platinum resistance thermometer

    N:      Two sinking transistor outputs                         7.  CompoWay/F serial communications

                                                                       FLK:    CompoWay/F serial communications

Note: 1.    Transfer output can be specified only when the control output is a current output.

        2.  The above model number legend is intended as a functional description of models. Not all possible combinations of functions  are

            available. Confirm model availability in Ordering Information on page 2 when ordering.

            Example: Voltage output, two sinking transistor outputs, heater burnout alarm, thermocouple: E5ZN-2TNH03TC-FLK

        Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital

            Controller.

            E5ZN Modular Temperature Controller User’s Manual (Cat. No. H113)

                                                                                                                                               1
                                                                                                                                                         E5ZN

Ordering Information

■ List of Models

Name             Power         No. of    Control         Auxiliary                   Functions             Communica-   Input type (See           Model

                 supply        control   output          output                                            tions func-     note 5.)

                               points                                                                      tions

                                                         Transistor                                                     Thermocouple     E5ZN-2QNH03TC-FLK

                                                         output: 2 pts                                                  Platinum

                                                         (sinking)                                                      resistance       E5ZN-2QNH03P-FLK

                                        Voltage                                                                         thermometer

                                        output           Transistor                                                     Thermocouple     E5ZN-2QPH03TC-FLK

                                        (for SSRs)       output: 2 pts

                                                         (sourcing)                                                     Platinum

                                                                        Heater                                          resistance       E5ZN-2QPH03P-FLK

                                                                        burnout alarm                                   thermometer

                                                         Transistor     (See note 3.)  Heating or                       Thermocouple     E5ZN-2TNH03TC-FLK

                                                         output: 2 pts                 heat/cool                        Platinum

                                                         (sinking)                     control is                       resistance       E5ZN-2TNH03P-FLK

Temperature                             Transistor                                     selectable                       thermometer

Controller (See  24 VDC     2           output           Transistor                    (See note 4.)       RS-485       Thermocouple     E5ZN-2TPH03TC-FLK

note 1.)                                                 output: 2 pts

                                                         (sourcing)                    Event input: 1                   Platinum

                                                                                       point per Unit                   resistance       E5ZN-2TPH03P-FLK

                                                                                                                        thermometer

                                        Analog           Transistor     Transfer out-                                   Thermocouple     E5ZN-2CNF03TC-FLK

                                        output           output: 2 pts  put (linear                                     Platinum

                                        (current         (sinking)      voltage out-                                    resistance       E5ZN-2CNF03P-FLK

                                        output)                         put)                                            thermometer

                                        (See note 2.)                   (See note 2.)

                                                         Transistor                                                     Thermocouple     E5ZN-2CPF03TC-FLK

                                                         output: 2 pts                                                  Platinum

                                                         (sourcing)                                                     resistance       E5ZN-2CPF03P-FLK

                                                                                                                        thermometer

Note: 1.  Terminal Units are required for wiring. Purchase separately.

      2.  When connecting the load of the controlled system, heat control output or cool control output can be allocated to the control output or

          auxiliary output. When connecting a recording device or Digital Panel Meter, transfer output can be allocated to control output or auxiliary

          output 3 or 4 of analog output models.

      3.  When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately.

      4.  When using heating and cooling control functionality, the auxiliary output will be either heating control output or cooling control output.

      5.  Analog input and infrared temperature sensors (ES1B) can also be used with thermocouple models.

■ Terminal Unit

          Name                         No. of terminals                                         Functions                                         Model

Terminal Unit               24                                      Equipped with communications terminals for power supply, commu-  E5ZN-SCT24S-500

(Includes bus system with-                                          nications, and setting devices.

out backplane.)             18 (See note 1.)                        Not equipped with communications terminals for power supply,     E5ZN-SCT18S-500

                                                                    communications, and setting devices.

Note: 1.  When using 2 or more E5ZNs mounted side-by-side, use the E5ZN-SCT18S-500 for the second and subsequent Units. When using

          E5ZNs separately, be sure to use the E5ZN-SCT24S-500.

      2.  Two End Plates are provided with a E5ZN-SCT24S-500 Terminal Unit. Up to 16 Terminal Units can be used to expand the system to                          a

          maximum of 32 channels. When mounting to a DIN Track, be sure to mount End Plates on both sides.

■ Accessories (Order Separately)

Terminal Cover                                                                         Setting Display Unit

Model        E53-COV12                        E53-COV13                                              Name               Power supply              Model

Type         For SCT24S-500 models            For SCT18S-500 models                    Setting Display Unit        24 VDC                E5ZN-SDL

                                                                                       (See note.)

Current Transformer (CT)                                                               Note: Purchase sockets for wiring (shown on page 2) separately.

Model                       E54-CT1                 E54-CT3

Diameter                    5.8 dia.                12.0 dia.

Sockets (for Setting Display Unit - Order Separately)

Model                           P2CF-11                              P2CF-11-E                        P3GA-11                         Y92A-48G

Type                            Front-connecting socket              Front-connecting socket          Back-connecting socket          Terminal cover for finger

                                                                     (with finger protection)                                         protection

Note: Refer to the following manual for precautionary information and other information necessary to use the E5ZN: E5ZN Temperature Controller

      Operation Manual (Cat. No. H113).

                                                                                                                                                                    2
                                                                                                                                                                                                       E5ZN

Specifications

■ Ratings

Power supply voltage                                              24 VDC

Allowable voltage range                                           85% to 110% of the rated power supply voltage

Power consumption                                                 Approx. 3 W

                                                                  Thermocouple: K, J, T, E, L, U, N, R, S, B

Sensor input                                                      Infrared temperature sensor (ES1B series): 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C

                                                                  Voltage input: 0 to 50 mV

                                                                  Platinum resistance thermometer: Pt100, JPt100

                                                                  Voltage output                      Output voltage: 12 VDC ±15% (PNP);

                                                                  (for driving SSR)                   Maximum load current: 21 mA;

                                                                                                      Equipped with short-circuit protection circuit

                                                                                                      Maximum operational voltage: 30 VDC;

Control output                                                    Transistor output                   Maximum load current: 100 mA;

                                                                                                      Residual voltage: 1.5 V max.;

                                                                                                      Leakage current: 0.4 mA max.

                                                                  Current output                      Current output range: 4 to 20/0 to 20 mA DC;

                                                                                                      Load: 350 Ω max. (See note 2.)

                                                                                                      Sourcing             Maximum operating voltage: 30 VDC;

                                                                  Transistor output                                        Maximum load current: 50 mA;

Auxiliary output                                                                                      Sinking              Residual voltage: 1.5 V max.;

                                                                                                                           Leakage current: 0.4 mA max.

                                                                  Linear voltage output                                    Voltage output range: 1 to 5/0 to 5 VDC;

                                                                                                                           Load: 10 kΩ min.

                                                                  Contact output                      ON: 1 kΩ max., OFF: 100 kΩ min.

Event input                                                                                           Discharge current: Approx. 7 mA

                                                                  Non-contact output                  ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                                                                                                      Discharge current: Approx. 7 mA

Number of input and control                        points         Input points: 2, Control points: 2

Setting method                                                    Via communications or using the Setting Display Unit (E5ZN-SDL)

Control method                                                    2-PID or ON/OFF control

Other functions                                                   Heater burnout detection function, transfer output function

                                                                  Multi-SP and RUN/STOP switching using event input

Ambient operating                                                 −10 to 55°C (with no icing or condensation)

temperature                                                       For 3 years of assured use: −10 to 50°C

Ambient operating humidity                                        25% to 85%

Storage temperature                                               −25 to 65°C (with no icing or condensation)

Note: 1.                      Do not use an inverter output for the power supply. (Refer to Safety Precautions for All Temperature Controllers.)

                        2.    OMRON G32A-EA Cycle Controller Unit (load impedance 352 Ω) can be used.

■ Input Range

Platinum Resistance Thermometer Models and Thermocouple Models

                                 Platinum resistance                                                                  Thermocouple models

                                 thermometer models

Input type                         Platinum resistance                                                Thermocouple                                           Infrared temperature        Analog input

                                    thermometer                                                                                                                     sensor

Name                                Pt100          JPt100               K            J            T       E     L          U         N   R     S      B      10 to  60 to 115 to 160 to  0 to 50 mV

                                                                                                                                                             70°C   120°C165°C 260°C

                        1800                                                                                                                          1800                               −1999 to

                        1700                                                                                                             1700  1700                                      9999 or

                        1600                                                                                                                                                             −199.9 to

                        1500                                                                                                                                                             999.9

Temperature range (°C)  1400                                      1300                                                             1300                                                  by scaling

                        1300

                        1200

                        1100

                        1000  850                                              850                              850

                        900

                        800

                        700                                                                               600

                        600         500.0          500.0                500.0

                        500                                                          400.0   400  400.0               400  400.0

                        400                                                                                                                                                   260

                        300                                                                                                                                         120  165

                        200                 100.0          100.0                                                                                             90

                        100                                                                                                                           100.0

                        0                   0.0            0.0                                            0                              0     0             0      0    0    0

                        −100                                            −20.0 −100   −20.0                      −100

                        −200  −200  −199.9         −199.9         −200                      −200  −199.9              −200 −199.9  −200

Setting                       0     1       2      3       4      0        1   2        3    4       17   5     6     7       18     8   9     10     11     12     13   14   15         16

number

The applicable                      standards for the input types are as             follows:

• K, J, T, E, N, R, S, B: JIS C1602-1995, IEC584-1

• L: Fe-CuNi, DIN 43710-1985

• U: Cu-CuNi, DIN 43710-1985

• JPt100: JIS C 1604-1989, JIS C 1606-1989

• Pt100: JIS C 1604-1997 IEC 751

Shaded parts indicate the settings at the time of purchase.

                                                                                                                                                                                                             3
                                                                                                                              E5ZN

■ Characteristics

                          Thermocouple: (Indicated value ±0.5% or ±1°C, whichever is greater) ±1 digit max. (See note 1.)

Indication                Platinum resistance thermometer: (Indicated value ±0.5% or ±1°C, whichever is greater) ±1 digit max. (See note

accuracy                  1.)

                          Analog input: ±0.5% or ±1 digit max.

                          CT input: ±5% FS ±1 digit max.

Influence of temperature  Thermocouple input (R, S, B): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                          Other thermocouple input: ( ±1% of PV or ±4°C, whichever is greater) ±1 digit max.

Influence of voltage      *K thermocouple at −100°C max.: ±10°C max.

                          Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

                          Analog input: (±1%FS) ±1 digit max.

Transfer output           Accuracy: ±0.5% FS (See note 2.)

Hysteresis                0.1 to 999.9 EU (in units of 0.1 EU)

                          (See note 3.)

Proportional band (P)     0.1 to 999.9 EU (in units of 0.1 EU)

                          (See note 3.)

Integral time (I)         0 to 3,999 s (in units of 1 s)

Derivative time (D)       0 to 3,999 s (in units of 1 s)

Control period            1 to 99 s (in units of 1 s)

Manual reset value        0.0 to 100.0% (in units of 0.1%)

Alarm setting range       −1,999 to 9,999 (Position of decimal point depends on input type.)

Sampling period           500 ms

Insulation resistance     20 MΩ min. (at 500 VDC)

Dielectric strength       600 VAC for 1 minute at 50 or 60 Hz (between unlike terminals of charged parts)

Vibration resistance      10 to 55 Hz, 10 m/s2 for 2 h each in X, Y, and Z directions

Shock resistance          150 m/s2 max., 3 times each in ±X, ±Y, and ±Z directions

                          Temperature Controller: Approx. 90 g

Weight                    Terminal Unit (18): Approx. 80 g

                          Terminal Unit (24): Approx. 100 g

Degree of protection      Temperature Controller: IP00

                          Terminal Unit: IP00

Memory protection         EEPROM (non-volatile memory) (Number of write operations: 100,000)

                          UL File No.:                                 E200593

                          CSA File No.:                                203889-1140084

                          CE EMS:              ESD                     EN61326, EN61000-4-2 (4 kV/contact, 8 kV/air)

                                               REM field               EN61326, EN61000-4-3 (10 V/m)

Approved standards                             Fast transient          EN61326, EN61000-4-4 (2 kV/DC power, 1 kV/I/O)

(See note 4.)                                  Surge immunity          EN61326, EN61000-4-5 (line to ground:  2 kV/DC power

                                                                                                              1 kV/I/O

                                                                                        line to line:         1 kV/DC power)

                                               Conducted RF            EN61326, EN61000-4-6 (10 V)

                          EMI:                 Radiated                EN61326 Class A

Note: 1.  The indication accuracy for T and N thermocouples at −100°C, and for U and L thermocouples is ±2°C ±1 digit max. There is no specifi-

          cation for the indication accuracy for the B thermocouple used at 400°C max. The indication accuracy for R and S thermocouples at

          200°C max. is ±3°C ±1 digit max.

2.        The transfer output accuracy for 0 to 4 mA when 0 to 20 mA DC is selected is ±0.5% FS +0.7 mA. The transfer output accuracy for 0 to

          1 V when 0 to 5 VDC is selected is ±0.5% FS +0.175 V.

3.        “EU” stands for “Engineering Unit.”

4.        In order to satisfy the EN61326 Class A standard for conducted emissions, install a noise filter (Densei-Lambda MXB-1206-33 or equiv-

          alent) in a DC power line as close to the E5ZN as possible.

                                                                                                                                                 4
                                                                                                                                      E5ZN

■ Communications                                                          ■ Current Transformer (CT)                        (Order

(Host Communications)                                                     Separately)

Transmission line      RS-485 multipoint                                  Dielectric strength      1,000 VAC (1 minute)

connection method                                                         Vibration resistance     50 Hz, 98 m/s2

Communications         RS-485 (2-wire, half-duplex)                                                E54-CT1: Approx. 11.5 g

method                                                                    Weight                   E54-CT3: Approx. 50 g

Synchronization        Start-stop synchronization                         Accessories              Armature (2)

method                                                                    (E54-CT3 only)           Plug (2)

Baud rate              4,800, 9,600, 19,200, or 38,400 bps

Transmission code      ASCII                                              ■ Heater Burnout Alarm

Data bit length        7 or 8 bits

(See note.)                                                               Maximum heater

Stop bit length (See                                                      current                  Single-phase, 50 A AC (See note 1.)

note.)                 1 or 2 bits

                                                                          Input current            ±5% FS ±1 digit max.

Error detection        Vertical parity (none, even, odd)                  readout accuracy

                       BCC (block check character)                        Heater burnout           0.0 to 50.0 A (in units of 0.1 A)

Flow control           None                                               alarm setting range      (See note 2.)

Interface              RS-485                                             Minimum detection ON     190 ms (See note 3.)

Retry function         None                                               time

Number of Units that                                                      Note: 1.  Use the K8AC-H Digital Heater Burnout Alarm Detector for

can be connected in    16 Units max. (32 channels)                                  burnout detection of 3-phase heaters.

parallel                                                                        2.  If the heater burnout alarm setting is set to 0.0 A, the alarm

Note: The baud rate, data bit length, stop bit length, and vertical par-            is always OFF, and if it is set to 50.0 A the alarm is always

     ity can all be set independently as host communications set-                   ON.

     tings.                                                                     3.  If the ON time for control output is less than 190 ms, heater

             : Default setting values                                               burnout detection and heater current measurement will not

                                                                                    be performed.

■ Setting Display Unit (Order

Separately)

Power supply voltage   24 VDC

Allowable voltage      85% to 110% of the rated power supply

range                  voltage

Power consumption      Approx. 1 W

Display method         7-segment digital display and single-color

                       display

Ambient operating      −10 to 55°C (with no icing or condensa-

temperature            tion)

                       For 3 years of assured use: −10 to 50°C

Ambient operating hu-  25% to 85%

midity

Storage temperature    −25 to 65°C (with no icing or condensa-

                       tion)

Communications         RS-485 (half-duplex)

method

Communications for-    Special protocol

mat

Insulation resistance  20 MΩ min. (at 500 VDC)

Dielectric strength    1,500 VAC for 1 minute at 50 or 60 Hz (be-

                       tween unlike terminals of charged parts)

Vibration resistance   10 to 55 Hz, 20 m/s2 for 2 h each in X, Y,

                       and Z directions

Shock resistance       300 m/s2 max., 3 times each in ±X, ±Y, and

                       ±Z directions

                       Front panel: IP50

Enclosure ratings      Rear case: IP20

                       Terminal case: IP00

Memory protection      EEPROM (non-volatile memory) (Number

                       of writes: 100,000)

Weight                 Approx. 100 g

                       Mounting bracket: Approx. 10 g

                                                                                                                                                    5
                                                                                                                                                                                    E5ZN

Installation

■ Connection Diagrams

•  Voltage output (control output) is not electrically isolated from internal circuitry. Therefore, when using grounded thermocouples, do not ground

   control output terminals. (Doing so may result in temperature measurement errors due to unwanted current paths.)

•  There is basic insulation between the power supply inputs and outputs for this product. If reinforced insulation is required, connect the input and

   output terminals to equipment without any exposed charge-carrying parts, or to equipment with basic insulation sufficient for the maximum

   operating voltage of the power supply and the inputs and outputs.

•  To comply with the standards for noise terminal voltage for class A in EN 61326, install a noise filter (Densei Lamda MXB-1206-33 or the

   equivalent) to the DC power line as close as possible to the Temperature Controller.

Using with the E5ZN-SCT24S-500

                                                                                                    Wiring for terminals 1 to 18 is the same as for the

                                                    +                                               E5ZN-SCT18-500. See below.

                                                           19      13      7       1

                                     24-VDC input

                                     power supply

                                                           20      14      8       2

                                                    −

                                                    B (+)  21      15      9       3

                           Setting Display Unit                                              Terminals upward

                           communications

                                                    A (−)  22      16      170     4

                                                    B (+)

                                                           23      17      181     5

                           Host communications

                                          RS-485

                                                           24      18      192     6

                                                    A (−)

                                                               E5ZN-SCT24S

                                                               (TOP VIEW)

Using with the             E5ZN-SCT18S-500

                                                                                                                 7+                   1+

                                                                                                        OUT1     4-20  mA  DC/  OUT2  4-20 mA  DC/

                                                                                                                 0-20  mA  DC         0-20 mA  DC

                                                                                                                 8−                   2−

                                                                                                              ch1                   ch2

                                                                                                                Current-output type

                                                                                                                E5ZN-2C@F03@-FLK

         13                      13                            13      7        1                                7+                   1+                    7                1

                                                                                      Event  input      OUT1       12 VDC  OUT2       12 VDC        OUT1               OUT2

   SUB1  14                SUB1  14                            14      8        2                                  21 mA              21 mA

                                                                                   Contact   Non-                8−                   2−                    8                2

   SUB2                    SUB2                                                    input     contact

         15  COM                 15  COM                       15      9        3            input              Voltage-output type                         ch1              ch2

                                                                                             +                  E5ZN-2Q@H03@-FLK                            Transistor-output type

   PNP (sourcing) type     NPN (sinking) type                                                −                                                              E5ZN-2T@H03@-FLK

   E5ZN-2@P@03@-FLK        E5ZN-2@N@03@-FLK

              16                 16 −                          16      10       4                   10     4               10             4                 10         4

         CT1               SUB3      1-5  -VVDDCC/                                           −          −                                                −          −

                                     0-5                       17      11       5                   11     5               11             5                 11         5

   CT2   ch1  17           SUB4  17 +     1-5 VDC/                                                                                                  V            V

   ch2                                    0-5 VDC              18      12       6                   12     6               12             6                 12         6

              18                 18 +                                                        +          +                                                +          +

   Voltage-output type     Analog-output type                                                   ch1        ch2             ch1           ch2                ch1        ch2

   E5ZN-2Q@H03@-FLK        (linear-voltage-output)                                           Thermocouple/infrared              Pt                       Analog input

   Transistor-output type  E5ZN-2C@F03@-FLK                E5ZN-SCT18S-500                   temperature sensor

   E5ZN-2T@H03@-FLK

E5ZN-SDL

   When the E5ZN-SCT24S-500 is used                        Do not use.

                                                                                                                                         24 VDC input power supply

                                 Connected to the E5ZN

                                 Temperature Controller

                                                                                                                               Note:  1. Terminals 4 and 9, 7 and 11,

                                                                                                                                          and 8 and 10 are connected

                                                                                                                                          internally at the E5ZN-SDL

                                                                                                                                          side.

                                                       Do not use.                                                                    2. Do not connect anything to

                                                                                                                                          terminals 1, 2, 5, and 6.

Note: Purchase either a P2CF-11 or a P3GA-11 Socket separately. (Refer to pages 10 to 11.)

                                                                                                                                                                                          6
                                                                                                                                                     E5ZN

Nomenclature

E5ZN-2

           Operation Indicators                                                                                   Unit Number Setting

                                                                                                                  Setting range of 0 to F      allows up

POWER                                                                                                             to 16 Units to be set.

Lights when power is turned ON.

ERROR                                                          POWER

Lights when a fatal error (e.g., memory                                                                               Baud Rate

error or sensor error) occurs.                                 ERROR

SD/RD (Communications Operation)

Flashes during communications with the host.                   SD/RD

OUT1 (Control Output 1)                                        OUT1

Lights when the control output 1 is ON.

OUT2 (Control Output 2)                                        OUT2

Lights when the control output 2 is ON.

                                                               SUB1

SUB1 (Auxiliary Output 1)

Lights when the auxiliary output 1 is ON.                      SUB2

SUB2 (Auxiliary Output 2)

Lights when the auxiliary output 2 is ON.

E5ZN-SDL

The following diagram shows the names and       functions  of  the E5ZN-SDL parts for when it is connected        to  the  E5ZN-2@@@@@@@.

           Operation Indicators                                Temperature Unit                                            No. 1 Display

• These indicators indicate the terminal                       Displayed when the display unit for setting                 Displays the PV or the type of

operations for the E5ZN-2@@@@@@@.                              data is temperature. The display is                         setting data.

• OUT1, OUT2 (Control Output 1, Control                        determined by the setting for temperature unit,

Output 2)                                                      with either  “°C” or  “°F” displayed accordingly.

Light when the control output 1 or the control                                                                             No. 2 Display

output 2 functions are ON.                                                                                                 Displays the target value, the

• SUB1, SUB2 (Auxiliary Output 1, Auxiliary                                                                                control variable, or the set value

Output 2)                                                                                                                  for setting data (setting contents).

Light when the auxiliary output 1 or the

auxiliary output 2 functions are ON.

• STOP                                                                                                                     Up Key

Lights when operation stops. Lights for an                                                                                 Each time this key is pressed, the

event or when RUN/STOP is set to STOP                                                                                      value displayed in No. 2

during control. Remains unlit at other times.                                                                              Display increases. If it is held

• CMW (Communications Write Control)                                                                                       down, the rate of increase

Lights when communications write is permitted                                                                              becomes faster.

and remains unlit when it is prohibited.                                                                                   It can also be used to move to the

• Some indicators are not used on the                                                                                      next setting item.

E5ZN-2@@@@@@@ (SUB3, SUB4).

                                                                                                                           Down Key

                                                                                                                           Each time this key is pressed, the

                                                                                                                           value displayed in No. 2

                                                                                                                           Display decreases. If it is held

                                                                                                                           down, the rate of decrease

                                                                                                                           becomes faster.

                                                                                                                           It can also be used to return to the

                                                                                                                           previous setting item.

                                                                                                                           Channel Key

           Unit/Channel Indicator                                                                                          Press this key to change the

           Indicates the unit number and                                                                                   channel number.

           the channel number.

           Level Key

           Press this key to switch setting                                                                                Copy Key

           levels.                                             UNIT Key                                                    Press this key to read all the

           Mode Key                                            Press to switch the unit number.                            settings from the Temperature

           Press this key to switch setting                                                                                Controller to the Setting Display

           data within the setting level.                      Level Key and Mode Key                                      Unit, or to write from the Setting

                                                               Press together to switch to protect mode.                   Display Unit to the Temperature

                                                                                                                           Controller.

                                                                                                                                                                 7
                                                                                                                     E5ZN

Dimensions

Note: All units are in millimeters unless otherwise  indicated.

E5ZN-2@@@03@-FLK Connected to

E5ZN-SCT24S-500                                                       22.3

                                                                                              UNIT

                                                                                              BPS

                                                                                              POWER

                                                                      72.8                    ERROR             130

                                                                                              SD/RD

                                                                                                    OUT1

                                                                                 E5ZN-SCT24S        OUT2

                                                                                                    SUB1

                                                                                                    SUB2

                                                                                                          E5ZN

When only using one Unit, purchase the E5ZN-

2@@@03@-FLK and the E5ZN-SCT24S-500 together.        27                                       30                4.7

Also, when using horizontal side-by-side mounting,       35

purchase the first Unit together with the E5ZN-              46

SCT24S-500.                                                      112

E5ZN-2@@@03@-FLK Connected to

E5ZN-SCT18S-500

                                                                                              UNIT

                                                                                              BPS

                                                                                              POWER

                                                                      72.8                    ERROR             130

                                                                                              SD/RD

                                                                                                    OUT1

                                                                                                    OUT2

                                                                                                    SUB1

                                                                                                    SUB2

                                                                                                          E5ZN

When mounting Units side-by-side, purchase the

E5ZN-2@@@03@-FLK together with the E5ZN-                                                                        4.7

SCT18S-500 for the second and subsequent Units.      27                     5.2                     22.5

                                                         35

                                                             46

                                                                 112

                                                                                                                           8
                                                                                                                                                      E5ZN

■ End Plate

PFP-M                                                10

                                                          6.2           1.8

                          Eight, M4

                          pan-head

                          screws                          1

                          50                                            35.5  35.3

                                                                   1.8

                          11.5

                                     10                   1.3                                Note: End Plates are provided with  the E5ZN-SCT24-500.

                                  M4 spring washer        4.8                                   Be sure to mount End Plates      at both ends of Unit blocks.

■ Current Transformer (Order                                            Separately)

E54-CT1

                                     21                            2.8

                                     15    5.8 dia.

                                                                        7.5

                 25   3

                                                    10.5

                                     40

                                                    Two, 3.5 dia.

                      10

                                     30

E54-CT3                                                                             E54-CT3 Accessories  Connection Example

                                                          2.36 dia.                 • Armature

                                30                                                                                                     Armature

                                           12 dia.                                                           Plug

                                                                        9           Approx.

                                                                                    3 dia.                                             Lead wire

             40 × 40

                                                                                                18

                                           Two, M3 (Depth: 4)                       • Plug

                 15                                                                 Approx.

                                                                                    6 dia.

                                30

                                                                                                (22)

■ Terminal Cover (Order Separately)

E53-COV12                                                                                    E53-COV13

                                                    26.8                                                                               26.8

             19                      29.8                                                                19                      22.3

                                                                                                                                                               9
                                                                                                                                                                                                                E5ZN

■ Rail Mounting Equipment (Order Separately)

Spacer

PFP-S                                                                                 16

                                                         5                         12

                                                                                          34.8

                                                                    44.3

                                                                                   16.5

Mounting Track

PFP-100N

PFP-50N                                                                                                                                    7.3±0.15

                                   4.5

                                                                                                                                                   35±0.3  27±0.15

                                                     15     25      10     25                      25          10  25         15 (5)                       1

                                                                           1000 (500)     (See note.)                         (See note.)

                                                                                                                   Note:      The figures in               parentheses    are dimensions for the PFP-50N.

■ Setting Display                  Unit

E5ZN-SDL                                                                                                                                                                  Panel Cutout Dimensions

                                                                                                                                                           Individual                          Side-by-side Mounting

                                                                                                                                                           Mounting                            (48  ×  No.  of  Units  –  2.5)  +1.0

                                                                                                   (84)                                                                                                                         0

                          48 × 48                                   6                     63.7                                14.2

                                                                                                                                                                                                                                      +0.60

                                                                                                                                                                                                                                      45

                                                                                                                                                   min.    45  +0.6

                                                                                                                                                   60          0

                                                                                                                                           44.8                                  •  The mounting panel thickness is 1

                                                                                                                                                                                    to 5 mm.

                                                                                                                                           44.8 ×                         +0.60  •  Vertical side-by-side mounting is

                                                                                                                                                                          45        not possible.

                                                                                                                                                                                    (Allow sufficient space above and

                                                                                                                                                                                    below.)

                                                                                                                                                                                 •  When mounting several Units,

                                                                                                                                                                                    make sure that the ambient

                                                                                                                                                                                    temperature specifications are not

                                                                                                                                                                                    exceeded.

■ E5ZN-SDL Wiring Sockets

Front-connecting Sockets

P2CF-11 (Standard Model)                                 50 max.                                                   31.2 max.

                         Two, 4.5-dia. holes

                                                                                          70 max.                                   35.4

                                                                                                                                                              Terminal Arrangement/

                                                                                      4                                                                       Internal Connections

                                                                                                                                                                     (TOP VIEW)

                         Eleven, M3.5 × 7.5 Sems screws                       7.8                  3                          4.5                                                                  Mounting Hole Cutout

                                                                                                                                                                       8  7         6  5

                                                                                                                                                                                       4                    Dimensions

P2F-11-E  (with  Finger  Protection)                                                                                                                                                                        Two, M4 or 4.5 dia.

                                                         50 max.                                                   31.2 max.                                                                                    40±0.2

                                                                                                                                                                       9               3

                                                            40±0.2                                                     30                                                                      Note: DIN track

                                                                                                                                                                     10   11        1  2

                                              8      7                  6     5                                                                                                                             mounting is

                         Two, 4.5-dia. holes                                                             3                                                                                                  also possible.

                                                         P2CF-11-E

                                                                           4

                                                                                          70 max.  1.2                              35.4

                                                  9                        3

                                                         10A250VAC

                                                         RESISTIVE

                                              10     11                 1     2       4

                         Eleven, M3.5 × 7.5 set      screws                      7.8                        5                       4.5

                                                                                                                                                                                                                                             10
                                                                                                                                                               E5ZN

Back-connecting Sockets

P3GA-11 (Standard Model)

                                             27 dia.                                         4  7  3             Terminal Arrangement/

                                                                                                                 Internal Connections

                                                                                                                 (BOTTOM VIEW)

                                  45                                              25.6                                       5  6     7  8

                                                                                                                 4

                                                                                                                 3                       9

                                             45                4.5          16.3  6.2                                        2  1  11    10

                                                                                                              6

    Note: Use in combination with a Terminal Cover (Y92A-                               8.7

                48G) for finger protection.

Terminal Cover

Y92A-48G                                     Twelve, 6.4 dia.

                                  34     Y92A-48G  UP          @47.7              @48

                                                   P   C

                                                               16.5

                                                                      24.6  27.6

                                             47.4

Safety Precautions

Refer to Safety Precautions for All Temperature Controllers.                                    13.Install switches or circuit-breakers so that the user can turn the

                                                                                                   power OFF immediately, and indicate these accordingly.

                       !WARNING                                                                 14.Do not use the product in the following locations:

Provide at least one power-interruption switch to                                                  • Locations subject to dust or corrosive gases (in particular,

ensure that the power is OFF before wiring. Not                                                    sulfide gas and ammonia gas)

doing so may result in electric shock.                                                             • Locations subject to freezing or condensation

                                                                                                   • Locations exposed to direct sunlight

■ Safety Precautions                                                                               • Locations subject to vibrations or shocks

                                                                                                   • Locations subject to exposure to water or oil

Observe the following points to ensure safe operation.                                             • Locations subject to heat radiated directly from heating

1.  Use and store the product within the specified temperature and                                 equipment

    humidity ranges. Cool the product (e.g., using fans) where                                     • Locations subject to intense temperature changes

    necessary.

2.  Do not touch the electronic components or pattern of the PCB.                               15.When the Terminal Unit is separated from the Temperature

    Hold the product by the case.                                                                  Controller, under no circumstances touch the electrical

3.  To ensure proper heat dissipation, leave a space around the                                    components or apply shock to the Temperature Controller.

    product. Do not block the product’s ventilating holes.                                      16.Do not use solvents to clean the product. Use commercial

4.  Use at the rated power supply voltage with the rated load.                                     alcohol.

5.  Be sure to connect terminals with the correct polarity.                                     17.After wiring is completed remove the dust-protection label to allow

                                                                                                   proper heat dissipation.

6.  Perform wiring using crimp terminals of the specified size. (E5ZN-                          18.When mounting the Temperature Controller to the Terminal Unit,

    SCT@S-500: M3.0, width 5.8 mm max.; E5ZN-SDL: M3.5, width                                      make sure that the hook on the side of the Temperature Controller

    7.2 max.)                                                                                      facing the Terminal Unit is inserted properly.

7.  Be sure to use wires satisfying the following specifications for                            19.Install the DIN track vertically.

    connection using bare wires.

    Power supply terminals: AWG 22 to 14

    Other terminals: AWG 28 to 16

    (Length of exposed part: 6 to 8 mm)

8.  Do not connect anything to unused terminals.

9.  Ensure that the rated voltage is reached within 2 seconds of

    turning power ON.

10.Allow 30 seconds’ warm-up time.

11.Install the product as far away as possible from devices that

    generate strong, high-frequency noise and devices that generate

    surges.

12.Keep wiring separate from high-voltage power lines or power lines

    carrying large currents. Do not wire in parallel with or together

    with power lines.

                                                                                                                                                                        11
                                                                                                                                          E5ZN

■ Precautions for Correct Use                                               Operating Precautions

                                                                            1.  A time of approximately 4 s is required after the power supply is

Service Life                                                                    turned ON until the outputs turn ON. Take this time into

                                                                                consideration when the Temperature Controller is incorporated in

Use within the following temperature and humidity ranges:                       a sequence circuit.

• Temperature: −10 to 55°C (with no icing or condensation)                  2.  Using the product near radios, televisions, or other wireless

• Humidity: 25% to 85%                                                          devices may result in reception interference.

If the product is installed inside a control panel, the temperature         Mounting and Dismounting

around the product (and not the temperature around the control

panel) must be kept below 55°C.                                             • To mount using a mounting track, first hook part A (see below) onto

With electronic devices like the E5ZN, the service life will depend not     the track and then push down on part B.

only on the number of switching operations performed by the relay

but also on the service life of the internal electronic components. The

service life of these components depends on the ambient

temperature; it will be shorter if the ambient temperature is high, and

longer if the ambient temperature is low. For this reason, the service

life of the product can be lengthened by keeping the inside of the

E5ZN at a low temperature.

If several Units are mounted side-by-side or are arranged vertically,

the heat generated may cause the internal temperature of the Units

to rise, reducing service life. To prevent this, take steps to ensure that

the Units are cooled, such as installing fans.

Ensure, however, that the terminals are not also cooled, otherwise

correct temperature measurement will not be possible.

Measurement Accuracy                                                        • To dismount, insert a flat-bladed screwdriver into part C, pull the

                                                                            hook down, and then lift the bottom part of the E5ZN upwards.

When extending the lead wires for thermocouples, use a

compensating conductor appropriate for the type of thermocouple

used.

When extending the lead wires for platinum resistance

thermometers, use lead wires with a low resistance, and make the

resistance in the 3 lead wires equal.

Make sure that the temperature sensor type and the input type of the

E5ZN are the same.

Mount the E5ZN horizontally.

If significant errors occur, check that input compensation has been

set correctly.

Waterproofing                                                                                                                    30 mm min.

The degree of protection is given below. Parts for which the degree of                                      Stopper

protection is not clearly indicated, and parts with IP@0 ratings (where

@ is not 0) do not have waterproof specifications.                          • Mount the E5ZN at least 30 mm away from other devices to ensure

• Temperature Controller: IP00                                              easy mounting and dismounting.

• Terminal Unit: IP00

                    ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                    To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                 In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                   12
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)

from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.                     ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.                                OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS

IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products.   This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given.             This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

•  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

•  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

   safety equipment, and installations subject to separate industry or government regulations.

•  Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the products may be changed without any notice.     When in doubt, special model numbers may be assigned to fix or

establish key specifications for your application on your request.  Please consult with your OMRON representative at any time to confirm actual

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent               the

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

                                                                                                                                                                         2010.6

                                                      In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/

                                                                                                          (c)Copyright OMRON Corporation 2010 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

E5ZN-2CN03P-309 24VDC   E5ZN-2CN03TC-309 24VDC   E5ZN-2CP03P-309 24VDC  E5ZN-2CP03TC-309 24VDC

E5ZN-2QNH03P-309 24VDC  E5ZN-2QNH03TC-309 24VDC  E5ZN-2TPH03P-309 24VDC  E5ZN-2TPH03TC-309

24VDC
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved