E5GN-R03P-FLK AC100-240器件文档内容

NO:    TC-037             PRODUCT: E5GN Temperature Controller
DATE:  October 2009
                          TYPE:            Discontinuation Notice

E5GN Temperature Controllers with Separate RTD and
Thermocouple Models will be Discontinued Dec. 31, 2009

Omron is streamlining the 1/32 DIN size E5GN temperature controller line by introducing E5GN-T
models that accept both Thermocouple and RTD inputs in a single unit. The E5GN with separate
models for thermocouple and RTD input will be discontinued December 31, 2009 or until stock is
depleted.

Discontinued Models/Suggested Replacement

Discontinued models       Suggested replacement
E5GN-RTC AC100-240        E5GN-RT AC100-240
E5GN-RP AC100-240         E5GN-RT-C AC100-240N6
E5GN-QTC AC100-240        E5GN-QT AC100-240
E5GN-QP AC100-240         E5GN-QT-C AC100-240N6
E5GN-R1TC AC100-240       E5GN-R1T AC100-240
E5GN-R1P AC100-240        E5GN-R1T-C AC100-240N6
E5GN-Q1TC AC100-240       E5GN-Q1T AC100-240
E5GN-Q1P AC100-240        E5GN-Q1T-C AC100-240N6
E5GN-R03TC-FLK AC100-240  E5GN-R103T-FLK AC100-240
E5GN-R03P-FLK AC100-240   E5GN-R103T-C-FLK AC100-240
E5GN-Q03TC-FLK AC100-240  E5GN-Q103T-FLK AC100-240
E5GN-Q03P-FLK AC100-240   E5GN-Q103T-C-FLK AC100-240
E5GN-RTC AC/DC24          E5GN-RTD AC/DC24
E5GN-RP AC/DC24           E5GN-RTD-C AC/DC24
E5GN-QTC AC/DC24          E5GN-QTD AC/DC24
E5GN-QP AC/DC24           E5GN-QTD-C AC/DC24
E5GN-R1TC AC/DC24         E5GN-R1TD AC/DC24
E5GN-R1P AC/DC24          E5GN-R1TD-C AC/DC24
E5GN-Q1TC AC/DC24         E5GN-Q1TD AC/DC24
E5GN-Q1P AC/DC24          E5GN-Q1TD-C AC/DC24
E5GN-R03TC-FLK AC/DC24    E5GN-R103TD-FLK AC/DC24
E5GN-R03P-FLK AC/DC24     E5GN-R103TD-C-FLK AC/DC24
E5GN-Q03TC-FLK AC/DC24    E5GN-Q103TD-FLK AC/DC24
E5GN-Q03P-FLK AC/DC24     E5GN-Q103TD-C-FLK AC/DC24

Important Differences

The model number is changed due to universal input types. The default value of Input Type
     parameter is modified from platinum resistance thermometer: Pt100 to thermocouple: K on the
     E5GN-[][][]P (models with platinum resistance thermometer). Change the setting of the Input
     Type to match the sensor that is used.

Wiring and terminal arrangement are changed due to the modification of the terminal block. Be
     sure to wire properly.

Detailed differences between new E5GN-T and E5GN-TC/E5GN-P models are shown on the
following pages.
Detailed Differences Between Models

Differences are indicated in red.

Case Color

Models to be discontinued                  Recommended replacement
E5GN-[][][]TC series/E5GN-[][][]P series   E5GN-[][][]T series
Case color: Smoky Gray                     Case color: Black

Dimensions                                 Recommended replacement
                                           E5GN-[][][]T series
Models to be discontinued                 Two types of terminal block:
E5GN-[][][]TC series/E5GN-[][][]P series  Models with Screw Terminals
                                           Models with Screw-Less Terminals
                                           Dimensions are modified.

Thickness of the Bezel: 3 mm               Models with Screw Terminals
Depth: 100 mm

                                                Thickness of the Bezel: 2 mm
                                                Depth: 99 mm
                                                Shape of ventilation slits is modified.

                                           Models with Screw-Less Terminals

Terminal Block                                  Thickness of the Bezel: 2 mm.
                                                Shape of ventilation slits is modified.
Models to be discontinued
E5GN-[][][]TC series/E5GN-[][][]P series  Recommended replacement
Screw Terminals:                          E5GN-[][][]T series
Terminals 1 to 6 for M2.6 screws          Screw Terminals: Terminals 1 to 12 for M3 screws
Terminals 7 to 9 for M2 screws

                                           Screw-Less Terminals: Terminals 1 to 12 for non-screws
Wiring Connections                                        Recommended replacement
                                                          E5GN-[][][]T series
Models to be discontinued                                Screw Terminals:
E5GN-[][][]TC series/E5GN-[][][]P series                 Which way to draw out:
Which way to draw out:                                   Horizontally against the terminal block
Vertically against the terminal block

                                                          Screw-Less Terminals:
                                                          Which way to draw out:
                                                          Vertically against the terminal block

Wiring Terminals                                          Recommended replacement
                                                          E5GN-[][][]T series
Models to be discontinued                                Screw Terminals:
E5GN-[][][]TC series/E5GN-[][][]P series                 Pin terminals changed to crimp terminals for M3 screws.
Terminals are connected as described below.              Tightening Torque 0.5Nm

The insulation stripped from wires inserted into the     Screw-Less Terminals:
terminals is 5 to 6 mm.                                  Electric wire: changed from "5 to 6 mm" to "10 mm"
                                                          Pin Terminals: changed from "5 to 6 mm" to "8 to 12 mm"
Tighten the terminal screws firmly.

                                                       3
Terminal Arrangement                             Recommended replacement
                                                 E5GN-[][][]T series
Models to be discontinued                       Number of Terminals: 12 terminals (1) to (12)
E5GN-[][][]TC series/E5GN-[][][]P series        Input terminals: (10) to (12)
Number of Terminals: 9 terminals (1) to (9)     RS-485 communications terminals: (7)(8)
Input terminals: (7) to (9)
RS-485 communications terminals: (5)(6)
Standard Model

Communication Model

                                                 Two input power supplies are available:
                                                 100 to 240 VAC or 24 VAC/VDC (no polarity).
                                                 Models depend on the power supply specification.

                                              4
Ratings/Performance Specifications

Continued next page
                                                                                5
6
Labels

                                                                                7
8
Model Number Legend                           Recommended replacement
                                              E5GN-[][][]T series
Models to be discontinued
E5GN-[][][]TC series/E5GN-[][][]P series

                                           9
How to Operate

Operation Manual

                                                                               10
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved