控制器 MEXLA 2Event 2A LM No Comm

参数
产品属性属性值
制造商:Omron
产品种类:控制器
发货限制:Mouser目前不销售该产品。
RoHS:详细信息
商标:Omron Automation and Safety
产品类型:Controllers
工厂包装数量:1
子类别:Controllers
零件号别名:E5EZPRR2BTAC100240
单位重量:260 g

E5EZ-PRR2BT AC100-240器件文档内容

New Product

Digital Temperature Controllers

E5@Z

1/16, 1/8, and 1/4 DIN Temperature

Controllers Join the Best-selling

E5@Z Series

• Models available with either temperature inputs or

analog inputs.

• A wide range of functions, such as a loop break alarm

(LBA), manual output, and transfer output.

• Easy-to-read 11-segment display.

• Faster sampling at 250 ms.

• Setting Tool port provided as a standard feature for easy

connection to personal computers.

• New protocol called Modbus is installed in the models

with communications.

                                        E5@Z Series

                                                                                                           Digital Position-proportional

                                                                                                           Controller

E5CZ                                E5EZ                       E5AZ                                        E5EZ-PRR

1/16 DIN                            1/8 DIN                    1/4 DIN                                     1/8 DIN

                                                      Contents

                              Digital Temperature Controllers

                                        E5CZ/E5CZ-U .................................                  2

                                        E5AZ/E5EZ .....................................                14

                                    E5EZ-PRR....................................................       37

                              Common to Updated E5@Z Controllers

                                    • Operation......................................................  26

                                    • Precautions ..................................................   33

                              E5EZ-PRR

                                    • Operation......................................................  43

                                    • Precautions ..................................................   59

                                                                                                                                          1
   Digital Temperature Controllers

   E5CZ/E5CZ-U(48 × 48 mm)

   This Best-selling General-purpose

   48×48-mm Temperature Controller

   Is Now Even Better.

   • Controllers now available with analog inputs.

   • Faster sampling at 250 ms.

   • Transfer output provided for easy output to recorders.

   • Models available with a loop break alarm (LBA) and

   heater short alarm (HS alarm).                                                      48 × 48 mm                         48 × 48 mm

   • Easy setting with 11-segment displays.                                                   E5CZ                        E5CZ-U

   • Setting protection indicator informs operator when

   protection is enabled.

   • Manual output provided.                                      Note: Refer to page 30 for information on changes in comparison                 to

   • New protocol called Modbus is installed in the models                             previous models.

   with communications.

   • USB-Serial conversion cable is available.

   Note: Refer to Precautions on page 33.

   Main I/O Functions

                             Event Inputs       E5CZ

                             • None

                             • Two                                2-level Display: PV and SV             4-digit Display

   Sensor Inputs                                                                                         • Auto/manual switching

   • Universal thermocouple/Pt inputs                                                  Alarm Outputs     • Models also available with RS-485

   (Models with temperature inputs)                                                    • Two             communications

   • Analog current/voltage inputs

   (Models with analog inputs)

   Indication Accuracy                          Control Output 1

   E5CZ                                         • Relay output

   • Thermocouple input: ±0.5% of PV            • Voltage output (for driving SSR)

   • Pt input: ±0.5% of PV                      • Current output

   • Analog input: ±0.5% FS

   E5CZ-U

   • Thermocouple input: ±1% of PV

   • Pt input: ±0.5% of PV

   Sampling Period

   • 250 ms

   This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions

   and other information required for operation before attempting to use the product.

   E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207)

   E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers Communications Manual (Cat. No. H208)

2
                                                                                                                         E5CZ/E5CZ-U

Model Number Structure

Model Number Legend

Controllers                                                                 Option Units

E5CZ-@2M@@                                                                  E53-CZ@@

            1  23    4  5                                                              1   2  3

1. Control Output 1                                                         1. Applicable Controller

    R: Relay output                                                              CZ: E5CZ

    Q: Voltage output (for driving SSR)                                     2. Function 1

    C: Current output                                                            Blank: None

2. Number of Alarms                                                              H:    Heater burnout/Heater      short  detection (CT1)

    2: Two alarms                                                           3. Function 2

3.  Option                                                                       B:    Two event inputs

    Blank: None                                                                  03: RS-485 communications

    M:      Option Unit can be mounted.

4.  Input Type

    T: Thermocouple, infrared sensor/platinum    resistance

        thermometer

    L: Analog current/voltage input

5.  Power Supply Voltage

    Blank: 100 to 240 VAC

    D:      24 VAC/VDC

Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-CZ@@).

Ordering Information

Controllers with Terminal Blocks

    Size             Power supply        Input type          Alarm  output  Mounting             Control output          Previous         New model

                        voltage                                             option units                                 model

                                                                                              Relay output        E5CZ-R2            E5CZ-R2T

                                                                            No                Voltage output      E5CZ-Q2            E5CZ-Q2T

                                         Thermocouple or                                      (for driving SSR)

                                         Resistance          2                                Relay output        E5CZ-R2M           E5CZ-R2MT

                                         thermometer                                          Voltage output

                 100 to 240 VAC                                             Yes               (for driving SSR)   E5CZ-Q2M           E5CZ-Q2MT

                                                                                              Current output      E5CZ-C2M           E5CZ-C2MT

                                                                                              Relay output        None               E5CZ-R2ML

1/16 DIN                                 Analog              2              Yes               Voltage output      None               E5CZ-Q2ML

48 × 48 × 78                             (current/voltage)                                    (for driving SSR)

(W × H × D)                                                                                   Current output      None               E5CZ-C2ML

                                                                                              Relay output        E5CZ-R2MD          E5CZ-R2MTD

                                         Thermocouple or                                      Voltage output

                                         Resistance          2              Yes               (for driving SSR)   E5CZ-Q2MD          E5CZ-Q2MTD

                                         thermometer

                 24 VAC/VDC                                                                   Current output      E5CZ-C2MD          E5CZ-C2MTD

                                                                                              Relay output        None               E5CZ-R2MLD

                                         Analog              2              Yes               Voltage output      None               E5CZ-Q2MLD

                                         (current/voltage)                                    (for driving SSR)

                                                                                              Current output      None               E5CZ-C2MLD

Option Units

One of the following Option Units can be mounted to provide the E5CZ with additional functions.

                                     Functions                                            Previous  model                       New  model

Communications RS-485                                                            E53-CN03N                        E53-CZ03

Communications RS-485                Heater burnout                              E53-CNH03N                       E53-CZH03

                                                             Event inputs        E53-CNBN                         E53-CZB

                                     Heater burnout          Event inputs        E53-CNHBN                        E53-CZHB

Note: Option Units cannot be used for plug-in models.

        These Option Units are applicable only to models released after October 2008.

                                                                                                                                                     3
   E5CZ/E5CZ-U

   Model Number Structure

   Model Number Legend (Plug-in-type                            Controllers)

   E5CZ-@2T@U

             1  2  3  4   5

   1. Output Type                                                             4. Power Supply Voltage

   R: Relay                                                                   Blank: 100 to 240 VAC

   Q: Voltage output (for driving SSR)                                        D:  24 VAC/VDC

   2. Number of Alarms                                                        5. Plug-in type

   2: Two alarms                                                              U: Plug-in type

   3. Input Type

   T: Thermocouple, infrared sensor/platinum resistance

   thermometer

   Ordering Information (Plug-in-type Controllers)

   Plug-in-Type Controllers

   Size               Power supply             Input type       Alarm output      Control output                Previous               New model

                             voltage                                                                            model

                                               Thermocouple or                Relay output                      None          E5CZ-R2TU

                   100 to 240 VAC              Resistance       2             Voltage output (for driving SSR)  None          E5CZ-Q2TU

   1/16 DIN                                    thermometer

                                               Thermocouple or                Relay output                      None          E5CZ-R2TDU

                   24 VAC/VDC                  Resistance       2             Voltage output (for driving SSR)  None          E5CZ-Q2TDU

                                               thermometer

   Accessories (Order Separately)

   USB-Serial Conversion Cable                                                Adapter

                                      Model                                   Connectable models                              Model

                               E58-CIFQ1                                      Terminal block models                           Y92F-45

   Terminal Cover                                                             Note: Use this Adapter when the panel has been previously prepared

                                                                                  for the E5B@.

   Connectable models                 Terminal block models                   Sockets (for Plug-in Models)

   Model                              E53-COV17

                                                                                                 Type                                  Model

   Waterproof Packing                                                         Front-connecting Socket                         P2CF-11

                                      Model                                   Front-connecting Socket with Finger Protection  P2CF-11-E

                                      Y92S-29                                 Back-connecting Socket                          P3GA-11

   Note: The Waterproof Packing is included with the Controller only for      Terminal Cover for Back-connecting socket with  Y92A-48G

   models with terminal blocks.                                               Finger Protection

   Current Transformers (CTs)

          Hole diameter                          Model

                5.8 dia.                         E54-CT1

             12.0 dia.                           E54-CT3

4
                                                                                                                          E5CZ/E5CZ-U

Specifications

Ratings

Power supply voltage                        100 to 240 VAC, 50/60 Hz                24 VAC, 50/60 Hz or 24 VDC

Operating voltage range         85% to 110% of rated supply voltage

Power con-      E5CZ            7.5 VA                                              5.5 VA (24 VAC)/3.5 W (24 VDC)

sumption        E5CZ-U          6 VA                                                4.5 VA (24 VAC)/2.5 W (24 VDC)

                                Models with temperature inputs

                                Thermocouple: K, J, T, E, L, U, N, R, S, or B

                                Platinum resistance thermometer: Pt100 or JPt100

Sensor input                    Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                Voltage input: 0 to 50 mV

                                Models with analog inputs

                                Current input: 4 to 20 mA or 0 to 20 mA

                                Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                 Current input: 150 Ω, Voltage input: 1 MΩ (Use a 1:1 connection when connecting the ES2-HB.)

                                E5CZ    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable

                Relay output            load: 5 V, 10 mA

                                E5CZ-U  SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load:

Control                                 5 V, 10 mA

output          Voltage output  E5CZ

                (for driving    E5CZ-U  Output voltage: 12 VDC ±15% (PNP), max. load current: 21 mA, with short-circuit protection circuit

                SSR)

                Current output  E5CZ    4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 2,700

Alarm output                    SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,

                                10 mA

                Contact input   ON: 1 kΩ max., OFF: 100 kΩ min.

Event input     Non-contact     ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                input

                                Outflow current: Approx. 7 mA per point

Control method                  ON/OFF control or 2-PID control (with auto-tuning)

Setting method                  Digital setting using front panel keys

Indication method               11-segment digital display and individual indicators (7-segments displays also possible)

                                Character height: PV: 11 mm, SV: 6.5 mm

Other functions                 Manual output, heating/cooling control, transfer output (on some models), loop break alarm, multi SP, MV

                                limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, etc.

Ambient operating               −10 to 55°C (with no icing or condensation)

temperature

Ambient operating humidity      25% to 85%

Storage temperature             −25 to 65°C (with no icing or condensation)

                                                                                                                                            5
   E5CZ/E5CZ-U

   Input Ranges

   Thermocouples/Platinum Resistance Thermometers (Universal Inputs)

                           Input           Platinum resistance                                                              Thermocouple                                               Infrared temperature       Analog

                           Type            thermometer                                                                                                                                          sensor                input

                           Name            Pt100             JPt100            K                  J               T             E  L             U          N        R     S  B     10 to  60 to  115 to  140 to  0 to 50 mV

                                                                                                                                                                                    70°C   120°C  165°C   260°C

                                                                                                                                                                              1800                                Usable in

                           1800                                                                                                                                   1700  1700                                      the

                           1700                                                                                                                                                                                   following

                           1600                                                                                                                                                                                   ranges by

                           1500                                                                                                                                                                                   scaling:

                           1400                                                                                                                                                                                   −1999 to

                                                                         1300                                                                               1300                                                  9999 or

                           1300                                                                                                                                                                                   −199.9 to

   Temperature range (°C)  1200                                                                                                                                                                                   999.9

                           1100

                           1000      850                                                    850                                    850

                           900

                           800

                           700                                                                                               600

                           600             500.0          500.0                   500.0

                           500                                                                       400.0  400      400.0                 400      400.0

                           400                                                                                                                                                                            260

                           300                                                                                                                                                             120    165

                           200                     100.0          100.0                                                                                                             90

                           100                                                                                                                                                100

                                  0                0.0            0.0                                                        0                                    0     0           0      0      0       0

                           −100.0                                                 −20.0     −100     −20.0                         −100

                           −200.0    −200  −199.9         −199.9         −200                               −200     −199.9                −200     −199.9  −200

   Setting                           0     1       2      3       4      5        6         7        8      9        10      11    12      13       14      15    16    17    18    19     20     21      22      23

   number

   The applicable standards for the input types                                             U: Cu-CuNi, DIN 43710-1985                                                  Shaded settings are the default settings.

   are as follows:                                                                          Pt100: IEC 751

   K, J, T, E, N, R, S, B: IEC584-1                                                         JPt100: JIS C 1604-1989, JIS C 1606-1989

   L: Fe-CuNi, DIN 43710-1985

   Models with Analog Inputs

                           Input Type                        Current                                           Voltage

   Input specification                             4 to 20mA         0 to 20 mA          1 to 5 V           0 to 5 V            0 to 10 V

                                                   Usable in the following ranges by scaling:

   Setting range                                   −1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or

                                                   −1.999 to 9.999

   Setting number                                  0                 1                   2                  3                   4                Shaded settings are the default settings.

6
                                                                                                                            E5CZ/E5CZ-U

Alarm Types                                                                 Note: 1.  With set values 1, 4 and 5, the upper and lower limit values

Select alarm types out of the 12 alarm types listed in the following                  can be set independently for each alarm type, and are

                                                                                      expressed as “L” and “H.”

table.                                                                      2.        Set value: 1, Upper- and lower-limit alarm

                                    Alarm output operation                            Case 1          Case 2                Case 3 (Always ON)

    Set   Alarm type          When X is posi-   When X is nega-                                                                                    H<0, L<0

   value                                                                              L       H  SP   SP L    H                H  SP    L

                                    tive              tive                            H<0, L>0        H>0, L<0                                     H<0, L>0

          Alarm function                                                              |H| < |L|       |H| > |L|             H     L SP             |H| ≥ |L|

0         OFF                 Output OFF                                                                                                           H>0, L<0

1                                                                                                                                 SP H          L  |H| ≤ |L|

          Upper- and lower-   ON       L     H                              3.        Set value: 4,  Upper- and lower-limit range

(See      limit               OFF               (See  note 2.)

note 1.)                               SP                                             Case 1          Case 2                Case 3 (Always ON)

                                             X        X                                                                                            H<0, L<0

2         Upper limit         ON                ON                                    L       H  SP   SP L    H                H  SP    L

                              OFF      SP       OFF   SP                                                                                           H<0, L>0

                                                                                      H<0, L>0        H>0, L<0

                              ON       X        ON                    X               |H| < |L|       |H| > |L|             H     L SP             |H| ≥ |L|

3         Lower limit         OFF               OFF                                                                                                H>0, L<0

                                       SP             SP

4                                                                                                                                 SP H          L  |H| ≤ |L|

          Upper- and lower-   ON       L     H                              4.        Set value: 5, Upper- and lower-limit with standby sequence

(See      limit range         OFF               (See  note 3.)                        For Upper- and Lower-Limit Alarm Described Above

note 1.)                               SP

                                                                                      • Case 1 and 2

5         Upper- and lower-   ON       L     H                                        Always OFF when the upper-limit and lower-limit

(See      limit with standby  OFF      SP       (See  note 4.)                        hysteresis overlaps.

note 1.)  sequence            (See  note 5.)                                          • Case 3: Always OFF

          Upper-limit with    ON             X  ON    X                     5.        Set value: 5, Upper- and lower-limit with standby sequence

6         standby sequence    OFF               OFF                                   Always OFF when the upper-limit and lower-limit hysteresis

                                       SP             SP                              overlaps.

          Lower-limit with    ON       X        ON                    X     6.        Set value: 12, LBA (loop break alarm) can be set only for

7         standby sequence    OFF               OFF                                   alarm 1 type.

                                       SP             SP

          Absolute-value      ON          X     ON       X                  Set the alarm types for alarms 1 to 3 independently in the initial setting

8         upper-limit         OFF               OFF                         level. The default setting is 2 (upper limit).

                                    0                                    0

          Absolute-value      ON          X     ON       X

9         lower-limit         OFF               OFF

                                    0                                    0

          Absolute-value                  X     ON       X

10        upper-limit with    ON

                              OFF   0           OFF                      0

          standby sequence

          Absolute-value                  X              X

11        lower-limit with    ON                ON

                              OFF   0           OFF                      0

          standby sequence

12        LBA (for alarm 1

(See      type only)          ---

note 6.)

                                                                                                                                                              7
   E5CZ/E5CZ-U

   Characteristics                                                                         Note:   1.  The indication accuracy of K thermocouples in the −200 to

                                                                                                       1300°C range, T and N thermocouples at a temperature of

                               Thermocouple: (See note 1.)                                             −100°C max., and U and L thermocouples at any

                               E5CZ:       (±0.5% of indicated value or ±1°C, whichever                temperature is ±2°C ±1 digit maximum. The indication

                                           is greater) ±1 digit max.                                   accuracy of the B thermocouple at a temperature of 400°C

                               E5CZ-U: (±1% of indicated value or ±2°C, whichever is

   Indication accuracy                     greater) ±1 digit max.                                      max. is not specified. The indication accuracy of the R and

                               Platinum resistance thermometer:                                        S thermocouples at a temperature of 200°C max. is ±3°C ±1

                                           (±0.5% of indicated value or ±1°C, whichever                digit max.

                                           is greater) ±1 digit max.

                               Analog input: ±0.5% FS ±1 digit max.                                2.  “EU” stands for Engineering Unit and is used as the unit

                               CT input: ±5% FS ±1 digit max.                                          after scaling. For a temperature sensor, the EU is °C or °F.

   Influence of temperature    R, S, and B thermocouple inputs:                                    3.  B, R, and S sensors: 0.2°C/Ω max. (100 Ω max.)

   (See note 2.)               (±1% of PV or ±10°C, whichever is greater) ±1 digit max.            4.  There is no waterproof function for the E5CZ-U.

                               Other thermocouple inputs:

                               (±1% of PV or ±4°C, whichever is greater) ±1 digit max.

   Influence of voltage        *±10°C for −100°C or less for K sensors                     USB-Serial Conversion Cable

   (See note 2.)               Platinum resistance thermometer inputs:

                               (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

                               Analog inputs:                                              Applicable OS                        Windows XP/Vista/7/8

                               (±1% of FS) ±1 digit max.

                               Models with thermocouple/platinum resistance                Applicable software                  Thermo Mini

                               thermometer input (universal input):                        Applicable models                    E5CZ/E5CZ-U/E5AZ/E5EZ

   Hysteresis                  0.1 to 999.9 EU (in units of 0.1 EU)                        USB interface standard               Conforms to USB Specification 1.1.

                               Models with analog input:

                               0.01 to 99.99% FS (in units of 0.01% FS)                    DTE speed                            38400 bps

                               Models with thermocouple/platinum resistance                                                     Computer: USB (type A plug)

                               thermometer input (universal input):

   Proportional band (P)       0.1 to 999.9 EU (in units of 0.1 EU)                        Connector specifications             Temperature Controller: Setup Tool port

                               Models with analog input:                                                                        (on bottom of Controller)

                               0.1 to 999.9% FS (in units of 0.1% FS)

   Integral time (I)           0 to 3999 s (in units of 1 s)                               Power supply                         Bus power (Supplied from USB host

                                                                                                                                controller.)

   Derivative time (D)         0 to 3999 s (in units of 1 s)                               Power supply voltage                 5 VDC

   Control period              0.5, 1 to 99 s (in units of 1 s)                            Current consumption                  70 mA

   Manual reset value          0.0 to 100.0% (in units of 0.1%)                            Ambient operating temperature        0 to 55°C (with no condensation or icing)

   Alarm setting range         −1999 to 9999 (decimal point position depends on input      Ambient operating humidity           10% to 80%

                               type)

   Sampling period             250 ms                                                      Storage temperature                  −20 to 60°C (with no condensation or

                               Thermocouple: 0.1°C/Ω max. (100 Ω max.) (See note 3.)                                            icing)

   Affect of signal source     Platinum resistance thermometer: 0.4°C/Ω max. (10 Ω         Storage humidity                     10% to 80%

   resistance                  max.)

   Insulation resistance       20 MΩ min. (at 500 VDC)                                     Altitude                             2,000 m max.

                               2,000 VAC, 50 or 60 Hz for 1 min (between terminals with    Weight                               Approx. 100 g

   Dielectric strength         different charge)                                           Note: A driver must be installed in the personal computer. Refer to

                  Malfunction  10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z                 installation information in the operation manual for the

   Vibration                   directions                                                          Conversion Cable.

   resis-

   tance          Destruction  10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in     Communications Specifications

                               X, Y, and Z directions

   Shock          Malfunction  100 m/s2 min., 3 times each in X, Y, and Z directions

   resis-                      300 m/s2 min., 3 times each in X, Y, and Z directions       Transmission line       RS-485 multipoint

   tance          Destruction                                                              connection method

                  E5CZ         Controller: Approx. 150 g, Mounting Bracket: Approx.        Communications          RS-485 (two-wire, half duplex)

   Weight                      10 g

                               Controller: Approx. 110 g, Mounting Bracket: Approx.        Synchronization         Start-stop synchronization

                  E5CZ-U       10 g                                                        method

                  E5CZ         Front panel: IP66 (indoor use)                              Baud rate               1200, 2400, 4800, 9600, 19200, or 38400 bps

   Degree of                   Rear case: IP20, Terminals: IP00                            Transmission code       ASCII

   protection     E5CZ-U       Front panel: Equivalent to IP50, Rear case: IP20,           Data length             7 or 8 bits

                               Terminals: IP00 (See note 4.)

   Memory protection           Non-volatile memory (number of writes: 1,000,000            Stop bits               1 or 2 bits

                               times)                                                                              Vertical parity (none, even, odd)

                               Emission    Enclosure:  EN55011 Group1 Class A              Error detection         Frame check sequence (FCS) with SYSWAY

                               Emission    AC Mains:   EN55011 Group1 Class A                                      Block check character (BCC) with CompoWay/F or

                               Immunity    ESD:    EN61000-4-2 4 kV contact discharge                              CRC-16 Modbus

                                                   (level 2)

                                                   8 kV air discharge (level 3)            Flow control            None

                               Immunity    RF-interference:

                                                   EN61000-4-3 10 V/m                      Interface               RS-485

                                                   (80-1000 MHz, 1.4-2.0 GHz amplitude     Retry function          None

                                                   modulated) (level 3)

                                                   10 V/m (900 MHz pulse modulated)        Communications

                               Immunity    Conducted Disturbance:                          buffer                  40 bytes

   EMC                                             EN61000-4-6 3 V

                                                   (0.15 to 80 MHz) (level 2)                                      0 to 99 ms

                               Immunity    Burst:  EN61000-4-4 2 kV Power-line (level 3)   Send data wait time     Default: 20 ms

                                                   1 kV I/O signal-line (level 3)

                               Immunity    Surge:  EN61000-4-5 1kV line to line            Note: The baud rate, data length, stop bits, and vertical parity can be

                                                   Power line, output line (relay output)          individually set using the Communications Setting Level.

                                                   2 kV line to ground

                                                   Power line, output line (relay output)

                                                   1 kV line to ground

                                                   Input line (communication)

                               Immunity    Voltage Dip/Interrupting:

                                                   EN61000-4-11 0.5 cycle, 100% (rated

                                                   voltage)

   Approved standards          UL 61010C-1

                               CSA C22.2 No.1010.1

                               EN61326, EN61010-1, IEC61010-1

   Conformed standards         VDE0106 Part 100 (Finger protection), when the

                               terminal cover is mounted.

8
                                                                                                                                                                E5CZ/E5CZ-U

Current Transformer (Order Separately)                                                       E54-CT1

Ratings                                                                                      Thru-current (Io) vs.                             Output Voltage (Eo)

Dielectric                                                                                   (Reference Values)

strength                                     1,000 VAC for 1 min                             Maximum continuous heater                         current: 50 A (50/60 Hz)

Vibration                                                                                    Number of windings: 400±2

resistance                                   50 Hz, 98 m/s2                                  Winding resistance: 18±2 Ω

Weight                                       E54-CT1: Approx. 11.5 g, E54-CT3: Approx. 50 g  (Eo) V (r.m.s.)  100 V      50 Hz

Accessories                                  Armatures (2)                                                    10                       ∞

(E54-CT3 only)                               Plugs (2)                                                                                 1 kΩ                        Distortion

Heater Burnout and Heater Short Alarms                                                                                                                             factor 10%

                                                                                                              1

                                                                                                                                                                   3%

Maximum                                                                                      Output voltage                                                    1%

heater current                            50 A AC                                                             100 mV

Input current                                                                                                 10                                  100 Ω

indication                                ±5% FS ±1 digit max.

accuracy

                                          0.1 to 49.9 A (in units of 0.1 A)                                   1                                   RL = 10 Ω

Heater burn-                              0.0 A: Heater burnout/Heater short alarm output

out alarm set-                            turns OFF.                                                          100 µV

ting range                                50.0 A: Heater burnout/Heater short alarm output

                                          turns ON.                                                           10

                                          Minimum detection ON time: 190 ms (See note 1.)                             1            10  100 mA  1         10         100 1,000 A

                                          0.1 to 49.9 A (in units of 0.1 A)                                                                    Thru-current (Io) A (r.m.s.)

                                          0.0 A: Heater burnout/Heater short alarm output    E54-CT3

Heater short                              turns ON.                                          Thru-current (Io) vs. Output Voltage (Eo)

alarm setting                             50.0 A: Heater burnout/Heater short alarm output

range                                     turns OFF.                                         (Reference Values)

                                          Minimum detection OFF time: 190 ms (See note       Maximum continuous heater current: 120 A (50/60 Hz)

                                          2.)                                                (Maximum continuous heater current for an OMRON Temperature

Note: 1.  If the ON time of control output 1 is less than 190 ms, heater                     Controller is 50 A.)

          burnout and the heater current will not be measured.                               Number of windings: 400±2

2.        If the OFF time of control output 1 is less than 190 ms,                           Winding resistance: 8±0.8 Ω

          heater short alarm and the heater current will not be

          measured.                                                                          (r.m.s.)         100 V         50 Hz

Electrical Life Expectancy Curve for                                                                          10                       ∞                                 Distortion

                                                                                                                                       1 kΩ                              factor 10%

Relays (Reference Values)                                                                    V                                         500 Ω                             3%

                                                                                             (Eo)                     1                                                1%

            Life (× 104 operations)  500                                                     Output voltage

                                     300                                                                      100 mV

                                                                                                                                                         100 Ω

                                                                                                              10                                         50 Ω

                                     100

                                                                                                                                                         RL = 10 Ω

                                     50                                                                               1

                                     30

                                                                                                              100 µV

                                     10

                                     5                                                                        10

                                               E5CZ                                                                      1         10  100 mA  1         10         100  1,000 A

                                     3         250 VAC, 30 VDC                                                                                 Thru-current (Io) A (r.m.s.)

                                               (resistive load)

                                               cosφ = 1

                                     1

                                          0    1         2       3  4        5  6

                                                                    Switching current (A)

                                                                                                                                                                                     9
E5CZ/E5CZ-U

External Connections

    • A voltage output (control output 1) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect

    any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured

    temperature values as a result of leakage current.

E5CZ

              Relay output                               +                                             Alarm output (Relay output)

              250 VAC, 3 A                                           1         11            6

              (Resistive load)              Control output 1                                                                   Alarm output (Relay

                                                                     2         12            7                 Alarm output 2  output), 250 VAC, 1 A

              Voltage output                             −                                       Alarm output 1, HB alarm/HS   (Resistive load)

              12 VDC, 21 mA     +                              A                                 alarm/input error

              Current output                                         3         13            8

              4 to 20 mA DC     mA                             B

                                −        −         −                 4         14            9

              0 to 20 mA DC                                                                            Input power supply

              Load 600 Ω max.       V                          B

                                         +         +                 5         15            10                     100 to 240 VAC

                                Analog input       TC/Pt                                                            24 VAC/DC (no polarity)

                                                   universal input

Option Units

        E53-CZH03                   E53-CZHB                   E53-CZ03                      E53-CZB

        Communications/             Event inputs/              Communications                Event inputs

        CT                          CT

                   B  11                       11                    B     11                              11

        RS-485                                              RS-485

                   A  12            EV1        12                    A     12                    EV1       12

              Do not  13                       13              Do not      13                              13

              use.                  EV2                        use.                             EV2

                      14                       14              Do not      14                Do not        14

              CT1                   CT1                        use.                          use.

                      15                       15              Do not      15                Do not        15

                                                               use.                          use.

E5CZ-U

        Relay output                                                                  Alarm output (Relay output),

        SPDT 250 VAC, 3 A                                                  6          250 VAC, 1 A (Resistive load)

                                Control output 1                     5             7      Alarm output 1/

        (Resistive load)                                                                  input error

                                                      +     4                         8          Alarm output 2

        Voltage output                                A

        12 VDC, 21 mA                                       3                             9

                                                      B

                                                      B           2                   10

                                            +                           1      11     Input power supply

                                         TC/Pt                                                   100 to 240 VAC

                                         universal input                                         24 VAC/DC (no polarity)

        Note: For the Wiring Socket, purchase the P2CF-11 or PG3A-11 separately.

10
                                                                                                                                                                           E5CZ/E5CZ-U

Nomenclature

E5CZ

E5CZ-U

The front panel is the same  for  the  E5CZ and E5CZ-U.

                                                                                            Temperature unit

                                                                                OMRON

                                                                                                                                     No. 1 display

                                                 Operation indicators

                                                                                                                                     No. 2 display

                                                                                                                                     Up Key

                                                             Level Key

                                                                                            Mode Key            Down Key

Dimensions

E5CZ                                                                    (84)                                                                                     Panel Cutout

Terminal Models              48 × 48             6                      78                                      44.8 × 44.8          Individual Mounting                         Group Mounting

                                                              1.5                                                                                                                                             +1.0

                                                                                                                                                                                                              0

                 OMRON

                                                                                                                                                                                                            45      +0.6

                                                                                                  58                                                                                                                   0

                                                                                                                                     60 min.                                     Waterproofing is not possible

                                                                                                                                                                                 when group mounting

                                                                                                                                                                                 Controllers.

                             Waterproof Packing  (Accessory)  Mounting Adapter (Accessory)                                                                       45        +0.6

                                                                                                                                                                           0

                                                                        (97)

                             48 × 48             6                      (91)                                                     48

                                                              1.5                                                                                   45     +0.6

                                                                                                                                                              0  •      Recommended panel thickness is

                 OMRON                                                                                                                                                  1 to 5 mm.

                                                                                                                                                                 •      Group mounting is not possible in

                                                                                                                                                                        the vertical direction. (Maintain the

                                                                                                      48.8      58                                                      specified mounting space between

                                                                                                                                                                        Controllers.)

                                                                                                                                                                 •      To mount the Controller so that it is

                                                                                                                                                                        waterproof, insert the waterproof

                                                                                                                                                                        packing onto the Controller.

                                                                                                                                                                 •      When two or more Controllers are

                                                                                                                                                                        mounted, make sure that the

                             Waterproof Packing (Accessory)   Mounting Adapter (Accessory)  Terminal Cover (E53-COV17)                                                  surrounding temperature does not

                                                                                            (Order separately)                                                          exceed the ambient operating

                                                              Note: The terminal            block cannot be removed.                                                    temperature given in the

                                                                                                                                                                        specifications.

E5CZ-U                                                                                                                                                           Panel Cutout

Plug-in Models                                                                                                                       Individual Mounting                         Group Mounting

                                                                                                                                                                                                        +1.0

                                                                                                                                                                                                         0

                                                    6                   (90.7)              14.2

                             48 × 48                                    70.5                                        44.8 × 44.8

                                                                                                                                                                                                         45   +0.6

                                                                                                                                                                                                                    0

                                                                                                                                     60 min.

                                                                                                      58

                                                                                                                                                                 45  +0.6

                                                                                                                                                                        0

                                                                                                                                                    45  +0.6

                                                 Mounting Adapter (Accessory)                                           48                              0            •     Recommended panel thickness is

                                                                                                                                                                           1 to 5 mm.

                                                              Note: There is no             waterproof    function for the           E5CZ-U.                         •     Group mounting is not possible in

                                                                                                                                                                           the vertical direction. (Maintain the

                                                                                                                                                                           specified mounting space between

                                                                                                                                                                           Controllers.)

                                                                                                                                                                     •     When two or more Controllers are

                                                                                                                                                                           mounted, make sure that the

                                                                                                                                                                           surrounding temperature does not

                                                                                                                                                                           exceed the ambient operating

                                                                                                                                                                           temperature given in the

                                                                                                                                                                           specifications.

                                                                                                                                                                                                                       11
E5CZ/E5CZ-U

Accessories

USB-Serial Conversion            Cable  (Order Separately)

E58-CIFQ1

                                                                                                 (2,100)

                                                                   250                    LED indicator (SD)                          1,765

                                            USB connector (type A plug)                                       LED indicator (RD)                       Serial connector

Terminal Cover (Order Separately)                                         Waterproof Packing

E53-COV17                               48                                Y92S-29 (for DIN 48 × 48)

                                                                                                 Order the Waterproof Packing separately if it becomes lost or

                                                                                                 damaged.

                                                                                                 The Waterproof Packing can be used to achieve an IP66

                           48.8                                                                  (indoor use) degree of protection.

                                                                                                 (Deterioration, shrinking, or hardening of the waterproof

                                                                                                 packing may occur depending on the operating environment.

                                                                                                 Therefore, periodic replacement is recommended to ensure

                                                                                                 the level of waterproofing specified in IP66 (indoor use). The

                                                                                                 time for periodic replacement depends on the operating envi-

                           22                                                                    ronment. Be sure to confirm this point at your site. Consider

                                                                                                 one year a rough standard. OMRON shall not be liable for

                                                                                                 the level of water resistance if the customer does not perform

                                                                                                 periodic replacement.)

                           9.1                                                                   The Waterproof Packing does not need to be attached if a

                  Note: The E53-COV10 cannot be                    used.                         waterproof structure is not required.

                                                                                                 Note: There is no waterproof function for the E5CZ-U.

    Unit Labels (Order Separately)

    Y92S-L1 Type                                 11.8                             Current Transformers (Order Separately)

                                                                   4.8            E54-CT1                                         21                         2.8

                                                                                                                                  15         5.8 dia.

                                                                                                                                                                  7.5

                                                                                                              25  3

                                                                                                                                                       10.5

                                                                                                                                  40

                                                                                                                                             Two, 3.5 dia.

                                                                                                                  10

                                                                                                                                  30

E54-CT3                                          2.36        dia.         E54-CT3 Accessory                   Connection          Example

                                 30                                       • Armature

                                        12 dia.                                                                                   Armature

                                                                                                                  Plug

                                                                   9

                                                                          Approx. 3 dia.                                                     Lead

                  40 × 40

                                                                                             18

                                        Two, M3  (depth: 4)               • Plug

                  15                                                      Approx. 6 dia.

                                 30                                                        (22)

12
                                                                                                                                                           E5CZ/E5CZ-U

Adapter (Order Separately)

Note: 1.  Use this Adapter when the panel has already been prepared for the E5B@.

2.        Only black is available.

Y92F-45                                                                                                                      Fixture (Accessory)

                                                                                  4.7             76

                                                                                                  69.6 to 77.6

                                        72 × 72

                                                                                                                                   67 × 67  87

Mounted to E5CZ                                                                              Panel (1 to 8 mm)

                                        72 × 72

                                                                            48 × 48

                                                                                  2.2        4.7

                                                                                                  77.3 (to back of E5CZ)

E5CZ-U Wiring Socket (Order Separately)

Front-connecting Socket

P2CF-11                  Eleven, M3.5 × 7.5                     3                 4.5           Terminal Layout/Internal Connections

                         sems screws                  7.8                                                       (Top View)

                                                                                                                8   7        6  5                          Mounting Holes

                                                                                                                                   4

                                                                                                                                                           Two, 4.5 dia. mounting  holes

                         70 max.                                                       35.4

                                                      Two,                                                      9                  3                       40±0.2

                                                      4.5-dia.

                                                      holes                                                     10  11       1  2               Note: Can  also be mounted to      a DIN  track.

                         4              50 max.

                                                                       31.2 max.

Note: A model with finger protection (P2CF-11-E)      is also available.

Back-connecting Socket

P3GA-11

                                             27 dia.                                              Terminal Layout/Internal Connections

                                                                                  4    7     3                      (Bottom View)

                                                                                                                          5     6  7   8

                                                                                                                          4

                                    45                                      25.6

                                                                                                                    3                  9

                                                                                                                          2     1  11  10

                                             45              4.5 16.3  6.2

                                                                                                      6

                                                                            8.7

Note: 1.  Using any other sockets will adversely affect accuracy. Use only the specified sockets.

2.        A Protective Cover for finger protection (Y92A-48G) is also available.

                                                                                                                                                                                                  13
    Digital Temperature Controllers

    E5AZ/E5EZ                                              (96 × 96 mm and 48 × 96 mm)

These Best-selling General-

purpose Temperature Controllers

Are Now Even Better.

    • Controllers now available with analog inputs.

    • Faster sampling at 250 ms.

    • Transfer output provided for easy output to

    recorders.

    • Models available with a loop break alarm (LBA)  and

    heater short alarm (HS alarm).

    • Manual output provided.

    • Easy setting with 11-segment displays.

    • New protocol called Modbus is installed in the

    models with communications.                                           96 × 96 mm                         48 × 96 mm

    • USB-Serial conversion cable is available.                           E5AZ                                          E5EZ

Note: Refer to Precautions on page 33.

                                                                     Note: Refer to page 30 for information on changes in comparison to

                                                                          previous models.

Main I/O Functions

                                                     E5AZ                 E5EZ

                         Event Inputs

                         • None                                                             2-level Display: PV and SV

                         • Two

    Sensor Inputs                                                                           4-digit Display

    • Universal thermocouple/Pt inputs

    (Models with temperature inputs)                                                                         • Auto/manual switching

    • Analog current/voltage inputs                                                                          • Models also available with

    (Models with analog inputs)                                           Alarm Outputs                      RS-485 or RS-232C

                                                                          • Three                            communications

    Indication Accuracy

    • Thermocouple input: ±0.5% of PV              Control Output 1

    • Pt input: ±0.5% of PV                        • Relay output

    • Analog input: ±0.5% FS                       • Voltage output (for  driving SSR)

                                                   • Current output

    Sampling Period

    • 250 ms

14
                                                                                                                           E5AZ/E5EZ

Model Number Structure

Model Number Legend

Controllers                                                                   Option Units

E5AZ/EZ-@3@@@@                                                                E53-AZ@

               1  2  3  4  5  6                                                    1       2

1. Control Output 1                                                           1. Applicable Controller

R: Relay output                                                               AZ: E5AZ/E5EZ

Q: Voltage output (for driving SSR)                                           2. Function

C: Current output                                                             01: RS-232C communications

2. Number of Alarms                                                           03: RS-485 communications

3: Three alarms                                                               B:   Two event inputs

3. Heater Burnout/Heater Short

Blank: None

H:         Heater burnout/Heater short detection (CT1)

4. Option

Blank: None

M: Option Unit can be mounted.

5. Input Type

T: Thermocouple, infrared sensor/platinum resistance

    thermometer

L: Analog current/voltage input

6. Power Supply Voltage

Blank: 100 to 240 VAC

D:         24 VAC/VDC

Ordering Information

Controllers with Terminal Blocks

                                                                                   Functions

Size           Power supply      Input type        Alarm   Control output     Heater          Mounting   Previous model      New model

                  voltage                          output                     burnout         option

                                                                                              units

                                                           Relay output       No              No        E5AZ-R3              E5AZ-R3T

                                                                                                        E5AZ-A3 + E53-AZR

                                                           Voltage output     No              No        E5AZ-Q3              E5AZ-Q3T

                                                           (for driving SSR)                            E5AZ-A3 + E53-AZQ

                                                           Current output     No              No        E5AZ-C3              E5AZ-C3T

                                                                                                        E5AZ-A3 + E53-AZC

                                 Thermocouple              Relay output       No              Yes       E5AZ-R3 + E53-AZM    E5AZ-R3MT

                                 or Resistance     3       Voltage output

                                 thermometer               (for driving SSR)  No              Yes       E5AZ-Q3 + E53-AZM    E5AZ-Q3MT

               100 to

               240 VAC                                     Current output     No              Yes       E5AZ-C3 + E53-AZM    E5AZ-C3MT

                                                           Relay output       Yes (CT1)       Yes       E5AZ-R3 + E53-AZM +  E5AZ-R3HMT

                                                                                                        E53-AZH

                                                           Voltage output     Yes (CT1)       Yes       E5AZ-Q3 + E53-AZM +  E5AZ-Q3HMT

1/4 DIN                                                    (for driving SSR)                            E53-AZH

96 × 96 × 78                                               Relay output       Yes (CT1)       Yes       None                 E5AZ-R3HML

(W × H × D)                      Analog (current/          Voltage output

                                 voltage)          3       (for driving SSR)  Yes (CT1)       Yes       None                 E5AZ-Q3HML

                                                           Current output     No              Yes       None                 E5AZ-C3ML

                                                           Relay output       No              Yes       None                 E5AZ-R3MTD

                                                           Voltage output     No              Yes       None                 E5AZ-Q3MTD

                                 Thermocouple              (for driving SSR)

                                 or Resistance     3       Current output     No              Yes       None                 E5AZ-C3MTD

                                 thermometer

               24 VAC/VDC                                  Relay output       Yes (CT1)       Yes       None                 E5AZ-R3HMTD

                                                           Voltage output     Yes (CT1)       Yes       None                 E5AZ-Q3HMTD

                                                           Relay output       Yes (CT1)       Yes       None                 E5AZ-R3HMLD

                                 Analog (current/  3       Voltage output     Yes (CT1)       Yes       None                 E5AZ-Q3HMLD

                                 voltage)                  (for driving SSR)

                                                           Current output     ---             Yes       None                 E5AZ-C3MLD

                                                                                                                                          15
E5AZ/E5EZ

Controllers with Terminal Blocks

                                                                                 Functions

    Size          Power supply  Input type        Alarm   Control output        Heater   Mounting  Previous model       New model

                      voltage                     output                        burnout  option

                                                                                         units

                                                          Relay output       No          No        E5EZ-R3              E5EZ-R3T

                                                                                                   E5EZ-A3 + E53-AZR

                                                          Voltage output     No          No        E5EZ-Q3              E5EZ-Q3T

                                                          (for driving SSR)                        E5EZ-A3 + E53-AZQ

                                                          Current output     No          No        E5EZ-C3              E5EZ-C3T

                                                                                                   E5EZ-A3 + E53-AZC

                                Thermocouple or           Relay output       No          Yes       E5EZ-R3 + E53-AZM    E5EZ-R3MT

                                Resistance        3       Voltage output

                                thermometer               (for driving SSR)  No          Yes       E5EZ-Q3 + E53-AZM    E5EZ-Q3MT

                  100 to

                  240 VAC                                 Current output     No          Yes       E5EZ-C3 + E53-AZM    E5EZ-C3MT

                                                          Relay output       Yes (CT1)   Yes       E5EZ-R3 + E53-AZM +  E5EZ-R3HMT

                                                                                                   E53-AZH

                                                          Voltage output     Yes (CT1)   Yes       E5EZ-Q3 + E53-AZM +  E5EZ-Q3HMT

    1/8 DIN                                               (for driving SSR)                        E53-AZH

    48 × 96 × 78                                          Relay output       Yes (CT1)   Yes       None                 E5EZ-R3HML

    (W × H × D)                 Analog (current/          Voltage output

                                voltage)          3       (for driving SSR)  Yes (CT1)   Yes       None                 E5EZ-Q3HML

                                                          Current output     No          Yes       None                 E5EZ-C3ML

                                                          Relay output       No          Yes       None                 E5EZ-R3MTD

                                                          Voltage output     No          Yes       None                 E5EZ-Q3MTD

                                Thermocouple or           (for driving SSR)

                                Resistance        3       Current output     No          Yes       None                 E5EZ-C3MTD

                                thermometer

                  24 VAC/VDC                              Relay output       Yes (CT1)   Yes       None                 E5EZ-R3HMTD

                                                          Voltage output     Yes (CT1)   Yes       None                 E5EZ-Q3HMTD

                                                          Relay output       Yes (CT1)   Yes       None                 E5EZ-R3HMLD

                                Analog (current/  3       Voltage output     Yes (CT1)   Yes       None                 E5EZ-Q3HMLD

                                voltage)                  (for driving SSR)

                                                          Current output     -           Yes       None                 E5EZ-C3MLD

Option Units

             Name                      Function                     Model

    Communications Unit         RS-232C Communications    E53-AZ01

                                RS-485 Communications     E53-AZ03

    Event Input Unit            Event input               E53-AZB

Accessories (Order Separately)

USB-Serial Conversion Cable

                                Model

                               E58-CIFQ1

Terminal Cover

    Connectable models                            Model

                  E5AZ                       E53-COV11

                  E5EZ

Waterproof Packing

    Connectable models                            Model

                  E5AZ                       Y92S-P4

                  E5EZ                       Y92S-P5

Current Transformers (CTs)

             Hole diameter                        Model

                 5.8 dia.                    E54-CT1

             12.0 dia.                       E54-CT3

16
                                                                                                                          E5AZ/E5EZ

Specifications

Ratings

Power supply voltage                        100 to 240 VAC, 50/60 Hz                24 VAC, 50/60 Hz or 24 VDC

Operating voltage range         85% to 110% of rated supply voltage

Power consumption               8.5 VA                                              6 VA (24 VAC)/4 W (24 VDC)

                                Models with temperature inputs

                                Thermocouple: K, J, T, E, L, U, N, R, S, or B

                                Platinum resistance thermometer: Pt100 or JPt100

Sensor input                    Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                Voltage input: 0 to 50 mV

                                Models with analog inputs

                                Current input: 4 to 20 mA or 0 to 20 mA

                                Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                 Current input: 150 Ω, Voltage input: 1 MΩ (Use a 1:1 connection when connecting the ES2-HB.)

                Relay output    SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load:       5  V,

                                10 mA

Control         Voltage output

output          (for driving    Output voltage: 12 VDC +15%/−20% (PNP), max. load current: 40 mA, with short-circuit protection circuit

                SSR)

                Current output  4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 2,700

Alarm output                    SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,

                                10 mA

                Contact input   ON: 1 kΩ max., OFF: 100 kΩ min.

Event input     Non-contact     ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                input

                                Outflow current: Approx. 7 mA per point

Control method                  ON/OFF control or 2-PID control (with auto-tuning)

Setting method                  Digital setting using front panel keys

                                11-segment digital display and individual indicators (7-segments displays also possible)

Indication method               Character height: E5AZ: PV: 15 mm, SV: 9.5 mm

                                            E5EZ: PV: 14 mm, SV: 9.5 mm

Other functions                 Manual output, heating/cooling control, transfer output (on some models), loop break alarm, multi SP, MV

                                limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, etc.

Ambient operating               −10 to 55°C (with no icing or condensation)

temperature

Ambient operating humidity      25% to 85%

Storage temperature             −25 to 65°C (with no icing or condensation)

                                                                                                                                                   17
E5AZ/E5EZ

Input Ranges

Thermocouples/Platinum Resistance Thermometers (Universal Inputs)

                            Input           Platinum resistance                                                               Thermocouple                                               Infrared temperature       Analog

                            Type            thermometer                                                                                                                                           sensor                input

                            Name            Pt100             JPt100             K                  J               T             E    L           U          N        R     S  B     10 to  60 to  115 to  140 to  0 to 50 mV

                                                                                                                                                                                      70°C   120°C  165°C   260°C

                                                                                                                                                                                1800                                Usable in

                            1800                                                                                                                                    1700  1700                                      the

                            1700                                                                                                                                                                                    following

                            1600                                                                                                                                                                                    ranges by

                            1500                                                                                                                                                                                    scaling:

                            1400                                                                                                                                                                                    −1999 to

                                                                           1300                                                                               1300                                                  9999 or

                            1300                                                                                                                                                                                    −199.9 to

    Temperature range (°C)  1200                                                                                                                                                                                    999.9

                            1100

                            1000      850                                                     850                                      850

                            900

                            800

                            700                                                                                                600

                            600             500.0          500.0                    500.0

                            500                                                                        400.0  400      400.0                 400      400.0

                            400                                                                                                                                                                             260

                            300                                                                                                                                                              120    165

                            200                     100.0          100.0                                                                                                              90

                            100                                                                                                                                                 100

                                   0                0.0            0.0                                                         0                                    0     0           0      0      0       0

                            −100.0                                                  −20.0     −100     −20.0                           −100

                            −200.0    −200  −199.9         −199.9          −200                               −200     −199.9                −200     −199.9  −200

    Setting                           0     1       2      3       4       5        6         7        8      9        10      11      12    13       14      15    16    17    18    19     20     21      22      23

    number

The applicable standards for the                                   input   types              U: Cu-CuNi, DIN 43710-1985                                                        Shaded settings     are   the default settings.

are as follows:                                                                               Pt100: IEC 751

K, J, T, E, N, R, S, B: IEC 584-1                                                             JPt100: JIS C 1604-1989, JIS                   C 1606-1989

L: Fe-CuNi, DIN 43710-1985

Models with Analog Inputs

                            Input Type                        Current                                            Voltage

    Input specification                             4 to 20mA           0 to 20 mA         1 to 5 V           0 to 5 V              0 to 10 V

    Setting range                                   Usable in the following ranges by scaling:

                                                    −1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or

                                                    −1.999 to 9.999

    Setting number                                  0                   1                  2                  3                     4                 Shaded settings are the default settings.

18
                                                                                                                                   E5AZ/E5EZ

Alarm Types

Select alarm types out of the 12 alarm types listed in the following table.

                                       Alarm output operation                Note: 1.  With set values 1, 4 and 5, the upper and lower limit values

                                                                                       can be set independently for each alarm type, and are

Set   value  Alarm type          When X is posi-   When X is nega-                     expressed as “L” and “H.”

                                       tive              tive                2.        Set value: 1, Upper- and lower-limit alarm

0            Alarm function      Output OFF                                            Case 1          Case 2                Case 3 (Always ON)

             OFF                                                                                                                                    H<0, L<0

1                                                                                      L       H  SP   SP L    H                H  SP    L

             Upper- and lower-   ON       L     H                                      H<0, L>0        H>0, L<0                                     H<0, L>0

(See  note   limit               OFF               (See  note 2.)                      |H| < |L|       |H| > |L|             H     L SP             |H| ≥ |L|

1.)                                       SP

                                                                                                                                                    H>0, L<0

                                 ON             X  ON    X                                                                         SP H          L  |H| ≤ |L|

2            Upper limit         OFF               OFF                       3.        Set value: 4,  Upper- and lower-limit range

                                          SP             SP

                                 ON       X        ON          X                       Case 1          Case 2                Case 3 (Always ON)

3            Lower limit         OFF               OFF                                                                                              H<0, L<0

                                          SP             SP                            L       H  SP   SP L    H                H  SP    L

4            Upper- and lower-            L     H                                      H<0, L>0        H>0, L<0                                     H<0, L>0

(See  note                       ON                (See  note 3.)                      |H| < |L|       |H| > |L|             H     L SP             |H| ≥ |L|

             limit range         OFF      SP

1.)                                                                                                                                                 H>0, L<0

5            Upper- and lower-            L     H                                                                                  SP H          L  |H| ≤ |L|

                                 ON                                          4.        Set value: 5, Upper- and lower-limit with standby sequence

(See  note   limit with standby  OFF      SP       (See  note 4.)                      For Upper- and Lower-Limit Alarm Described Above

1.)          sequence            (See  note 5.)                                        • Case 1 and 2

             Upper-limit with    ON             X  ON    X                             Always OFF when the upper-limit and lower-limit

6            standby sequence    OFF               OFF                                 hysteresis overlaps.

                                          SP             SP

             Lower-limit with    ON       X        ON          X                       • Case 3: Always OFF

7            standby sequence    OFF               OFF                       5.        Set value: 5, Upper- and lower-limit with standby sequence

                                          SP             SP                            Always OFF when the upper-limit and lower-limit hysteresis

             Absolute-value      ON          X     ON       X                          overlaps.

8            upper-limit         OFF               OFF

                                       0                          0          6.        Set value: 12, LBA (loop break alarm) can be set only for

             Absolute-value      ON          X     ON       X                          alarm 1 type.

9            lower-limit         OFF               OFF                       Set the alarm types for alarms 1 to 3 independently in the initial setting

                                       0                          0

             Absolute-value                                                  level. The default setting is 2 (upper limit).

                                 ON          X     ON       X

10           upper-limit with    OFF               OFF

             standby sequence          0                          0

             Absolute-value                  X              X

11           lower-limit with    ON                ON

                                 OFF   0           OFF            0

             standby sequence

12           LBA (for alarm 1

(See  note   type only)          ---

6.)

                                                                                                                                                               19
E5AZ/E5EZ

Characteristics                                                                                       5.  When using the E53-AZB, E53-AZ01, or E53-AZ03 Option

                                                                                                          Unit with the E5AZ-@3@M@@ to satisfy the immunity burst

                             Thermocouple: (See note 1.)                                                  requirements in the EN 61326 standard, always connect a

                             (±0.5% of indicated value or ±1°C, whichever is greater) ±1                  ZCAT2035-0930 Clamp Filter (manufactured by TDK) to the

                             digit max.

    Indication accuracy      Platinum resistance thermometer:                                             cable for terminals 11, 12, and 13.

                             (±0.5% of indicated value or ±1°C, whichever is greater) ±1

                             digit max.

                             Analog input: ±0.5% FS ±1 digit max.                             USB-Serial Conversion Cable

                             CT input: ±5% FS ±1 digit max.

    Influence of tempera-    R, S, and B thermocouple inputs:                                 Applicable OS                       Windows XP/Vista/7/8

    ture (See note 2.)       (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                             Other thermocouple inputs:                                       Applicable software                 Thermo Mini

                             (±1% of PV or ±4°C, whichever is greater) ±1 digit max.

    Influence of voltage     *±10°C for −100°C or less for K sensors                          Applicable models                   E5CZ/E5CZ-U/E5AZ/E5EZ

                             Platinum resistance thermometer inputs:

    (See note 2.)            (±1% of PV or ±2°C, whichever is greater) ±1 digit max.          USB interface standard              Conforms to USB Specification 1.1.

                             Analog inputs:

                             (±1% of FS) ±1 digit max.                                        DTE speed                           38400 bps

                             Models with thermocouple/platinum resistance thermometer                                             Computer: USB (type A plug)

                             input (universal input):                                         Connector specifications            Temperature Controller: Setup Tool port

    Hysteresis               0.1 to 999.9 EU (in units of 0.1 EU) (See note 3.)

                             Models with analog input:                                                                            (on bottom of Controller)

                             0.01 to 99.99% FS (in units of 0.01% FS)                                                             Bus power (Supplied from USB host

                             Models with thermocouple/platinum resistance thermometer         Power supply                        controller.)

                             input (universal input):

    Proportional band (P)    0.1 to 999.9 EU (in units of 0.1 EU) (See note 3.)               Power supply voltage                5 VDC

                             Models with analog input:

                             0.1 to 999.9% FS (in units of 0.1% FS)                           Current consumption                 70 mA

    Integral time (I)        0 to 3999 s (in units of 1 s)                                    Ambient operating temperature       0 to 55°C (with no condensation or icing)

    Derivative time (D)      0 to 3999 s (in units of 1 s)                                    Ambient operating humidity          10% to 80%

    Control period           0.5, 1 to 99 s (in units of 1 s)                                                                     −20 to 60°C (with no condensation or

    Manual reset value       0.0 to 100.0% (in units of 0.1%)                                 Storage temperature                 icing)

    Alarm setting range      −1999 to 9999 (decimal point position depends on input type)     Storage humidity                    10% to 80%

    Sampling period          250 ms                                                           Altitude                            2,000 m max.

    Affect of signal source  Thermocouple: 0.1°C/Ω max. (100 Ω max.) (See note 4.)            Weight                              Approx. 100 g

    resistance               Platinum resistance thermometer: 0.4°C/Ω max. (10 Ω max.)        Note: A driver must be installed in the personal computer. Refer to

    Insulation resistance    20 MΩ min. (at 500 VDC)                                                  installation information in the operation manual for the

    Dielectric strength      2,000 VAC, 50 or 60 Hz for 1 min (between terminals with                 Conversion Cable.

                             different charge)

    Vibration   Malfunction  10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions   Communications Specifications

    resis-      Destruction  10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y,

    tance                    and Z directions                                                 Transmission line con-    RS-485 multipoint

    Shock       Malfunction  100 m/s2 min., 3 times each in X, Y, and Z directions            nection method            RS-232C

    resis-      Destruction  300 m/s2 min., 3 times each in X, Y, and Z directions            Communications            RS-485 (two-wire, half duplex), RS-232C

    tance

                E5AZ         Controller: Approx. 300 g, Mounting Bracket: Approx. 100 g       Synchronization           Start-stop synchronization

    Weight                                                                                    method

                E5EZ         Controller: Approx. 250 g, Mounting Bracket: Approx. 100 g       Baud rate                 1200, 2400, 4800, 9600, 19200, or 38400 bps

    Degree of protection     Front panel: IP66 (indoor use),

                             Rear case: IP20, Terminals: IP00                                 Transmission code         ASCII

    Memory protection        Non-volatile memory (number of writes: 1,000,000 times)          Data length (See note.)   7 or 8 bits

                             Emission Enclosure: EN55011 Group1 Class A                       Stop bits (See note.)     1 or 2 bits

                             Emission AC Mains:        EN55011 Group1 Class A

                             Immunity ESD:      EN61000-4-2 4 kV contact discharge (level                               Vertical parity (none, even, odd)

                                                2)                                                                      Frame check sequence (FCS) with SYSWAY

                                                8 kV air discharge (level 3)                  Error detection           Block check character (BCC) with CompoWay/F or

                             Immunity RF-interference:

                                                EN61000-4-3 10 V/m                                                      CRC-16 Modbus

                                                (80-1000 MHz, 1.4-2.0 GHz amplitude

                                                modulated) (level 3)                          Flow control              None

                                                10 V/m (900 MHz pulse modulated)

                             Immunity Conducted Disturbance:                                  Interface                 RS-485, RS-232C

    EMC                                         EN61000-4-6 3 V                               Retry function            None

                                                (0.15 to 80 MHz) (level 2)

                             Immunity Burst:    EN61000-4-4 2 kV Power-line (level 3)         Communications

                                                1 kV I/O signal-line (level 3) (See note 5.)                            40 bytes

                             Immunity Surge:    EN61000-4-5 1kV line to line                  buffer

                                                Power line, output line (relay output)

                                                2 kV line to ground                           Send data wait time       0 to 99 ms

                                                Power line, output line (relay output)                                  Default: 20 ms

                                                1 kV line to ground

                                                Input line (communication)                    Note: The baud rate, data length, stop bits, and vertical parity can be

                             Immunity Voltage Dip/Interrupting:                                       individually set using the Communications Setting Level.

                                                EN61000-4-11 0.5 cycle, 100% (rated

                                                voltage)

    Approved standards       UL 61010C-1                                                      Current Transformer (Order Separately)

                             CSA C22.2 No.1010.1

                             EN61326, EN61010-1, IEC61010-1                                   Ratings

    Conformed standards      VDE0106 Part 100 (Finger protection), when the terminal

                             cover is mounted.                                                Dielectric strength      1,000 VAC for 1 min

Note: 1.        The indication accuracy of K thermocouples in the −200 to                     Vibration                50 Hz, 98 m/s2

                1300°C range, T and N thermocouples at a temperature of                       resistance

                −100°C max., and U and L thermocouples at any

                temperature is ±2°C ±1 digit maximum. The indication                          Weight                   E54-CT1: Approx. 11.5 g, E54-CT3: Approx.

                accuracy of the B thermocouple at a temperature of 400°C                                               50 g

                max. is not specified. The indication accuracy of the R and                   Accessories              Armatures (2)

                S thermocouples at a temperature of 200°C max. is ±3°C ±1                     (E54-CT3 only)           Plugs (2)

                digit max.

            2.  Conditions: Ambient temperature: −10°C to 23°C to 55°C,

                Voltage range: −15% to +10% of rated voltage

            3.  “EU” stands for Engineering Unit and is used as the unit

                after scaling. For a temperature sensor, the EU is °C or °F.

            4.  B, R, and S sensors: 0.2°C/Ω max. (100 Ω max.)

20
                                                                                                                                                                               E5AZ/E5EZ

Heater Burnout and Heater Short Alarms                                                      E54-CT1

Maximum                                                                                     Thru-current (Io) vs.                                         Output Voltage (Eo)

heater current                            50 A AC                                           (Reference Values)

Input current                                                                               Maximum continuous heater                                     current: 50 A (50/60 Hz)

indication                                ±5% FS ±1 digit max.                              Number of windings: 400±2

accuracy                                                                                    Winding resistance: 18±2 Ω

                                          0.1 to 49.9 A (in units of 0.1 A)                 (Eo) V (r.m.s.)                 100 V      50 Hz

Heater burn-                              0.0 A: Heater burnout/Heater short alarm output

out alarm                                 turns OFF.                                                                        10                    ∞

setting range                             50.0 A: Heater burnout/Heater short alarm output                                                        1 kΩ

                                          turns ON.                                                                                                                        Distortion

                                          Minimum detection ON time: 190 ms (See note 1.)                                   1                                              factor 10%

                                          0.1 to 49.9 A (in units of 0.1 A)                 Output voltage                                                                  3%

                                                                                                                                                                        1%

                                          0.0 A: Heater burnout/Heater short alarm output                 100 mV

Heater short                              turns ON.

alarm setting                             50.0 A: Heater burnout/Heater short alarm output

range                                     turns OFF.                                                                        10                               100 Ω

                                          Minimum detection OFF time: 190 ms (See note

                                          2.)                                                                               1                                RL = 10 Ω

Note: 1.  If the ON time of control output 1 is less than 190 ms, heater

          burnout detection and the heater current will not be

          measured.                                                                                                         100 µV

2.        If the OFF time of control output 1 is less than 190 ms,

          heater short alarm and the heater current will not be                                                             10

          measured.                                                                                                                 1         10  100 mA  1         10         1001,000 A

                                                                                                                                                          Thru-current (Io) A (r.m.s.)

Electrical Life Expectancy Curve for                                                        E54-CT3

Relays (Reference Values)                                                                   Thru-current (Io) vs. Output Voltage (Eo)

            Life (× 104 operations)  500                                                    (Reference Values)

                                     300                                                    Maximum continuous heater current: 120 A (50/60 Hz)

                                                                                            (Maximum continuous heater current for an OMRON Temperature

                                     100                 E5EZ                               Controller is 50 A.)

                                                         250 VAC, 30 VDC                    Number of windings: 400±2

                                                         (resistive load)

                                     50                  cosφ = 1                           Winding resistance: 8±0.8 Ω

                                     30                                                     Output voltage (Eo) V (r.m.s.)

                                                                                                                            100 V      50 Hz

                                     10                                                                                                           ∞                             Distortion

                                                                                                                            10                    1 kΩ

                                                                                                                                                  500 Ω                         factor 10%

                                     5                                                                                                                                          3%

                                     3                                                                                      1                                                   1%

                                     1                                                                                      100 mV

                                          0    1      2  3         4         5  6                                                                                   100 Ω

                                                                Switching current (A)                                                                        50 Ω

                                                                                                                            10

                                                                                                                                                                    RL = 10 Ω

                                                                                                                            1

                                                                                                                            100 µV

                                                                                                                            10

                                                                                                                                    1         10  100 mA  1         10         1001,000 A

                                                                                                                                                          Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                            21
E5AZ/E5EZ

External Connections

    • The voltage output for control output 1 is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not

    connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured

    temperature values as a result of leakage current.

    E5AZ/E5EZ

                                              Option    Units       E53-AZB                 E53-AZ01            E53-AZ03

                                                                    Event input             RS-232C             RS-485

100 to 240 VAC                                                              +          EV1     SD               B(+)

24 VAC/DC (no polarity)   Input power supply            EV2

Relay output 250 VAC,                                               EV1     +          EV2     RD               A(−)

5 A (Resistive load)                +                                                          SG

Voltage output                                                                                                  Do not use

12 VDC, 40 mA             Control output 1              One CT

Current output                      −                          CT1

4 to 20 mA DC

0 to 20 mA DC

Load 600 Ω max.           Alarm output 3

Alarm output                                            Do not use

(Relay output),

250 VAC, 2 A                                            Do not use

(Resistive load)

                          Alarm output 2                                    A

                                                                                   Pt                        +

                                                        TC−                 B               −  mA

                          Alarm output 1,                                                                    −

                          HB alarm/HS                                                       V

                          alarm/ input                                      B

                          error                                +                            +

                                                        TC/Pt universal input               Analog input

Nomenclature

                                        E5AZ                                                                              E5EZ

    Temperature unit                                                                   Operation indicators     OMRON

                          OMRON

                                                                    No. 1 display

    Operation indicators                                                                                                        No. 1 display

                                                                                       Temperature unit

                                                                                                                                No. 2 display

                                                                                       Operation indicators

                                                                    No. 2 display

              Level Key                                             Up Key

                                                                                            Mode Key

                          Mode Key  Down Key

                                                                                            Level Key           Down Key        Up Key

22
                                                                                                                                       E5AZ/E5EZ

Dimensions

E5AZ

            96                                                      11.2

                                                                                     78                                                91

                                                                               2

                                                                96  112                                                                                      91

                Waterproof Packing                                                Mounting Bracket

                (Accessory)                                                       (Accessory)

                                                                    11.2

            96                                                                       84.5                                             91

                                                                               2

                                                                96  112                                                                                      92.5

                Waterproof Packing                                                Mounting Bracket        Terminal Cover (E53-COV11)

                (Accessory)                                                       (Accessory)             (Order separately)

                                                                                                          Crimp terminal size: M3.5

                                                                                                          Panel Cutout

                                                                                     Individual Mounting                      Group Mounting

                                                                                                                                                    +1.0

                                                                                         92+00.8                                                    0

                                                                                                                                                             92+00.8

Note: To remove the Controller from the case, loosen the screw at

      the bottom of the front panel with a screwdriver while

      pressing down on the hook at the top of the front panel.

                                                                          120  min.                                Waterproofing is not possible when

                                                                                                                   group mounting Controllers.

                                                                                                                   •  Recommended panel thickness is 1 to

                                                                                                                      8 mm.

                                                                                                                   •  Group mounting is not possible in the

                                                                                                                      vertical direction. (Maintain the

                                                                                                          92+00.8     specified mounting space between

                                                                                                                      Controllers.)

                                                                                                                   •  To mount the Controller so that it is

                                                                                                                      waterproof, insert the waterproof

                                                                                                                      packing onto the Controller.

                                                                                                                   •  When two or more Controllers are

                                                                                                                      mounted, make sure that the

                                                                                                                      surrounding temperature does not

                                                                                                                      exceed the ambient operating

                                                                                                                      temperature given in the

                                                                                                                      specifications.

                                                                                                                                                                      23
E5AZ/E5EZ

E5EZ

Terminal Models

                                  11.2

                                                                    78                                             44

                 48                                              2

                     96           112                                                                                              91

                     Waterproof Packing                             Mounting Bracket

                     (Accessory)                                    (Accessory)

                         11.2

                 48                                                 84.5

                                         2                                                                44

                     96           112                                                                                           92.5

                     Waterproof Packing                             Mounting Bracket  Terminal Cover (E53-COV11)

                     (Accessory)                                    (Accessory)       (Order separately)

                                                                                      Crimp terminal size: M3.5

                                                                                                          Panel Cutout

                                                                                      Individual Mounting                             Group Mounting

                                                                                                                                                             +1.0

                                                                                                                                                                0

                                                                                                          45+00.6

                                                                                                                                                      92+00.8

    Note: To remove the Controller from the case, loosen the screw

      at the bottom of the front panel with a screwdriver while                       120 min.                                     Waterproofing is not possible when

      pressing down on the hook at the top of the front panel.                                                                     group mounting Controllers.

                                                                                                                                •  Recommended panel thickness is 1 to

                                                                                                                                   8 mm.

                                                                                                                                •  Group mounting is not possible in the

                                                                                                                                   vertical direction. (Maintain the

                                                                                                                       92+00.8     specified mounting space between

                                                                                                                                   Controllers.)

                                                                                                                                •  To mount the Controller so that it is

                                                                                                                                   waterproof, insert the waterproof

                                                                                                                                   packing onto the Controller.

                                                                                                                                •  When two or more Controllers are

                                                                                                                                   mounted, make sure that the

                                                                                                                                   surrounding temperature does not

                                                                                                                                   exceed the ambient operating

                                                                                                                                   temperature given in the

                                                                                                                                   specifications.

24
                                                                                                                                              E5AZ/E5EZ

Accessories

USB-Serial Conversion   Cable         (Order Separately)

E58-CIFQ1

                                                                                                     (2,100)

                                                                 250                     LED indicator (SD)                            1,765

                                      USB connector (type A plug)                                            LED indicator (RD)                         Serial connector

Terminal Covers                       13                                         Waterproof Packing

E53-COV11                                                                        Y92S-P4 (for DIN 96 × 96)                       Y92S-P5      (for DIN 48 × 96)

(Two Covers provided.)                         6.5 dia.

(Order Separately)

                                92.3

                        10.5                   6.5

                                8                                                Order the Waterproof Packing separately if it becomes lost or damaged.

                                                                                 The Waterproof Packing can be used to achieve an IP66 (indoor use) degree

                                                                                 of protection.

                                                                                 (Deterioration, shrinking, or hardening of the waterproof packing may occur

                                                                                 depending on the operating environment. Therefore, periodic replacement is

                                                                                 recommended to ensure the level of waterproofing specified in IP66 (indoor

                                                                                 use). The time for periodic replacement depends on the operating environ-

Unit Labels (Order Separately)                                                   ment. Be sure to confirm this point at your site. Consider one year a rough

                                                                                 standard. OMRON shall not be liable for the level of water resistance if the

                                                           11.8                  customer does not perform periodic replacement.)

Y92S-L1 Type                                                                     The Waterproof Packing does not need to be attached if a waterproof structure

                                                                                 is not required.

                                                                    4.8

                                                                                 Current Transformers (Order Separately)

                                                                                 E54-CT1                                           21                         2.8

                                                                                                                                   15         5.8 dia.

                                                                                                                                                                   7.5

                                                                                                              25  3

                                                                                                                                                        10.5

                                                                                                                                 40

                                                                                                                                              Two, 3.5 dia.

                                                                                                                  10

                                                                                                                                 30

E54-CT3                                        2.36        dia.          E54-CT3 Accessory                   Connection Example

                        30                                               • Armature

                                      12 dia.                                                                                      Armature

                                                                                                                  Plug

                                                                 9

                                                                         Approx. 3 dia.                                                       Lead

              40 × 40

                                                                                                 18

                                      Two, M3  (depth: 4)                • Plug

                    15                                                   Approx. 6 dia.

                        30                                                                (22)

                                                                                                                                                                          25
E5@Z

Operation

Setting Levels Diagram

This diagram shows all of the setting levels. To move to the advanced function setting level, you must enter passwords. Some parameters                               are      not

displayed depending on the protect level setting and the conditions of use.

Control stops when you move from the operation level to the initial setting level.

                                                          Power ON

                    Started in manual mode.                         Started in automatic mode.

                    Press the O Key

                    for at least 1 s.                                                                                                           Press the O +

                                                        Operation Level                Adjustment Level                                         M keys; display

                             C  a-m                                       Press the                              Press the O                    will flash.

                                                                          O Key less than 1 s.                   + M Keys for            C      25

                                                                                                                 at least 1 s.

                                Press the O Key for     Press the                   C  25         Press the O Key for at                           100

                        (See    at least 1 s; display   O Key                                     least 1 s; display will flash.

                        note    will flash.                                            100        Press the O Key for at

    Manual                      Press the Ol Key for    for at      (See                          least 3 s.                                       Press the O +

    mode                2.)     at least 3 s while a-m  least 1 s.  note 1.)                                  Control stops.

                                                                                                                                                   M Keys for at

                                                                                                                                                   least 3 s. (See

                                                                                                                                                   note.)

                 Manual Control                                                                   Communi-

                 Level                                    Initial Setting Level                   cations

                                                                                       Press the  Setting                              Protect  level

                                                                                       O Key for less than 1 s.

                                             Press the O Key                           Input password.                             Note: The time taken to move

                                             for at least 1 s.                         Set value −169                                    to the protect level can

                                                                                                                                         be adjusted by

                                                                    Advanced Function                                                    changing the "Move to

                                                                    Setting Level                                                        protect level time"

                                                                                                                                  Control in progress

                                                                                                                                  Control stopped

                                                                                                                                  Not displayed for some models

                                                                                                                                  Level change

Note: 1.  Moves to operation level by software reset.

    2.    From the manual control level, key operations can be used to move to the operation level only.

Error Displays (Troubleshooting)

When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below.

                                                                                                                                                       Output status at error

    No. 1 display               Meaning                                                Action                                                      Control    Alarm outputs

                                                                                                                                                   outputs

                        Input error          Check the wiring of inputs for miswiring, disconnections, and short-circuits and check the                       Operates as

                        (See note 2.)        input type.                                                                                        OFF           above the upper

                                                                                                                                                              limit.

    s.err (S. Err)      A/D converter        Check for an input error and then cycle the power supply. If the same error is still

                        error                displayed, repairs will be necessary.                                                              OFF           OFF

                        (See note 2.)        If the Temperature Controller is normal after cycling the power supply, the error may have

                                             been caused by noise. Check for noise being generated nearby.

    e111 (E111)         Memory error         Cycle the power supply. If the same error is still displayed, repairs will be necessary.           OFF           OFF

    h.err (H. Err)      HB error             If the Temperature Controller is normal after cycling the power supply, the error may have         OFF           OFF

                        (See note 2.)        been caused by noise. Check for noise being generated nearby.

Note: 1.  If the input value exceeds the display limit (−1999 to 9999), though it is within the control range,                           will be displayed under −1999 and

                    above 9999. Under these conditions, control output and alarm output will operate normally.

          For details on the control range, refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207).

    2.    These errors are displayed only when the PV/SP is displayed. Errors are not displayed in other display modes.

26
E5@Z

27
E5@Z

Parameters

    Some parameters are not displayed depending on the

    model of the Controller and parameter settings. For details,                                                                                           Press the O Key for at

    refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital                                                                                                             least 3 s. Displays other than

                                                                                                                   Power ON                                that for switching between

    Temperature Controllers User's Manual (Cat. No. H207).                                                                                                 automatic and manual.

                                                                                     Starting in manual mode.

                                                                                                   Manual control level                      Starting in   automatic

                                                                                                                                             mode.

                                                                                     C              25 PID control         Press the

                                                                                                       only                O Key for

                                                                                     PV/MV                                 at least 1 s

                                         Press the O Key less than 1 s.

       Adjustment Level                                                                                                            Operation Level

                                         Press the O Key less than 1 s.

                                                                                                    C     25    Process value                C      al-1         Alarm value 1         Set either of these parameters.

                                         C      p    Proportional band                                          Added when Additional                      0

                                            8.0                                                           M     PV display is ON.                          M

                                            M                                                       C     25    Process value/               C      al1h         Alarm value

    P  at    AT execute/cancel           P      i    Integral time                                           0  set point                                  0     upper limit 1

       off                                  233                       PID settings                        M     Auto/manual switch                         M

       M                                    M                                                       P  a-m      PID control only.            C      al1l         Alarm value

       cmwt  Communications writing      P      d    Derivative time                 Press the                  Added when auto/manual                     0     lower limit 1

                                                                                     OKey for             M     select addition is ON.                     M

       off                                      40                                   at least 3 s.  P  m-sp                                  C      al-2         Alarm value 2         Set either of these parameters.

       M                                    M                                                                   Multi-SP

    P  ct1   Heater current 1 value      P c-sc      Cooling coefficient                                     0  set point setting                          0

       0.0   monitor                        1.00                                                          M                                                M

                                                                     Heating/cool-                  C  sp-m     Set point during SP          C      al2h         Alarm value

       M                                    M                        ing                                        ramp                                             upper limit 2

    P  lcr1  Leakage current 1           C c-db      Dead band                                               0                                             0

       0.0   monitor                        0.0                                                           M                                                M

                                                                                                    P  ct1      Heater current 1 value       C      al2l         Alarm value

       M                                    M                                                             0.0   monitor                                    0     lower limit 2

    P  hb1   Heater burnout detection 1  P of-r      Manual reset value

                                                     Clear the offset during sta-                         M                                                M                           Set either of these parameters.

       0.0                                  50.0     bilization of P or PD control.                 P  lcr1     Leakage current 1            C      al-3         Alarm value 3

       M                                    M                                                             0.0   monitor                                    0

    P  hs1   HS alarm 1                  C  hys      Hysteresis (heating)                                 M                                                M

       50.0                                 1.0                       Hysteresis                    P  r-s      RUN/STOP                     C      al3h         Alarm value

       M                                    M                         settings                            run                                              0     upper limit 3

    C  sp-0  SP 0                        C chys      Hysteresis (cooling)                                 M                                                M

       0                                    1.0                                                                                              C      al3l         Alarm value

       M                                    M                                                                                                              0     lower limit 3

    C  sp-1  SP1                         C sprt      SP ramp set value                                                                                     M

       0                 SP used by         off                                                                                              P             o     MV monitor

       M                 multi-SP           M                                                                                                              0.0   (heating)

    C  sp-2  SP 2                        P ol-h      MV upper limit                                                                                        M

                                                                                                                                             P             c-o   MV monitor

       0                                    105.0                                                                                                                (cooling)

       M                                    M                                                                                                              0.0

    C  sp-3  SP 3                        P ol-l      MV lower limit                                                                                        M

       0                                    -5.0

       M                                    M                                                                                                                                      Press the OKey

    C  ins   Temperature input shift                                                 Press the O and M Keys for at                      Press the O and M Keys

                                                                                     least 3 s. Display flashes.                        for at least 1 s.                          less than 1 s

       0.0               1-point shift

       M                                                                                                  Protect Level                      Communications Setting Level

    C  insh  Upper-limit temperature     Set either  of these parameters.

       0.0   input shift value                                                       The time taken to move to the protect level can be      Displayed only for models with communications.

                         2-point shift                                               adjusted by changing the "Move to protect level         Changes are effective after cycling power or

       M                                                                             time" setting.                                          after a software reset.

    C  insl  Lower-limit temperature

       0.0   input shift value                                                                            Operation/adjustment protect              psel         Protocol setting

                                                                                                P  oapt   Restricts displaying and                               Switches between CompoWay/F

       M                                                                                                  modifying menus in operation,                    cwf   (SYSWAY) and Modbus.

                                                                                                       0  adjustment, and manual

                                                                                                          control levels.                                  M

                                                                                                    M     Initial setting/communications            u-no         Communications Unit No.

                                                                                                P  icpt   protect                                             1

                                                                                                          This protect level restricts                     M

                                                                                                       1  movement to the initial setting,

                                                                                                    M     communications setting, and                      bps   Communications baud rate

                                                                                                          advanced function setting levels.                                     CompoWay/F

                                                                                                P  wtpt                                                    9.6                  (SYSWAY) only

                                                                                                          Setting change protect                           M

                                                                                                    off   Protects changes to setups by                          Communications

                                                                                                          operating the front panel keys.                  len   data length

                                                                                                    M                                                         7

                                                                                                                                                           M

                                                                                                                                                    sbit         Communications stop bits

                                                                                                                                                              2

                                                                                                                                                           M

                                                                                                                                                    prty         Communications parity

                                                                                                                                                           even

                                                                                                                                                           M

                                                                                                                                                    sdwt         Send data wait time

                                                                                                                                                           20

                                                                                                                                                           M

28
                                                                                                                                                           E5@Z

                                                         Press the O Key for at least 1 s.

   Initial Setting Level                                        Advanced Function Setting       Level

Press the O Key less than 1 s.

P  in-t   Input type

      5                                                      P  init  Parameter initialization  P pvad     Additional PV display     amad  Auto/manual select

   M                                                                                               off                                     addition

P  in-h   Scaling upper limit                                   off                                                                  off

                                                                M                                  M                                 M

   100                                                       P  ev-m  Number of multi-SP uses   P o-dp     MV display             P  hsu   HS alarm use

   M                                                                  Two SPs: 1                   off

P  in-l   Scaling lower limit                                      1  Four SPs: 2                                                    on

      0                                                         M                                  M                                 M

                                                             P  ev-1  Event input               P  ret     Automatic display      P  hsl   HS alarm latch

   M                                                                  assignment 1                         return time

P  dp     Decimal point                                         none                               off                               off

      0                                                         M                                  M                                 M

   M                 For input type of analog                P  ev-2  Event input               P a1lt     Alarm 1 latch          P  hsh   HS alarm hysteresis

P  d-u    Temperature unit                                      stop  assignment 2                 off                               0.1

      c   °C, °F           For input type of                    M                                  M                                 M

                           temperature                       P                                  P a2lt     Alarm 2 latch          P

   M                                                            mspu  Multi-SP uses                                                  lba   LBA detection time

C  sl-h   SP upper limit                                        off                                off                                  0

   1300                    Limit the set point                  M                                  M                                 M

   M                                                         P  spru  SP ramp time unit         P a3lt     Alarm 3 latch          C lbal   LBA level

C  sl-l   SP lower limit                                           m                               off

                                                                                                                                     8.0

   -200                                                         M                                  M                                 M

   M                                                         P  rest  Standby sequence          P prlt     Move to protect level  C lbab   LBA band

P  cntl   PID ON/OFF                                                  reset                                time

                                                                   a                                   3                             3.0

   onof                                                         M                                  M                                 M

   M                                                         P  al1n  Alarm 1 open in alarm     P sero     Input error output     P out1   Control output 1

P  s-hc   Standard or heating/cooling                                                                                                      assignment

   stnd                                                         n-o                                off                                  o

                           For input type of tem-               M                                  M                                 M

   M                       perature, standard                                                   P  cjc     Cold junction compen-

          ST               control, or PID                   C  alh1  Alarm 1 hysteresis                                          P alm1   Alarm output 1

P  st                                                                                                      sation method

                           When assigning PID                   0.2                                    on                            alm1  assignment
          (self-tuning) or control output to
   on
                           pulse output                         M                                  M                                 M

   M                                                         P                                  P rlrv     MB command logic

P  cp     Control period (heating)                              al2n  Alarm 2 open in alarm                switching              P alm2   Alarm output    2

                                                                n-o                                off                               alm2  assignment

   20                                                                                              M

   M                 Set the pulse output cycle.                M                                                                    M

P  c-cp   Control period (cooling)                           C  alh2  Alarm 2 hysteresis        P a1on     Alarm 1 ON delay       P alm3   Alarm output    3

                                                                                                       0                                   assignment

   20                                                           0.2                                                                  alm3  (E5AZ/E5EZ only)

   M                                                            M                                  M                                 M

P  oreV   Direct/reverse operation                           P  al3n  Alarm 3 open in alarm     P a2on     Alarm 2 ON delay       P csel   Character select

   or-r                                                         n-o                                    0                             on

   M                                                            M                                  M                                 M

P  alt1   Alarm 1 type                                       C  alh3  Alarm 3 hysteresis        P a3on     Alarm 3 ON delay

      2                                                         0.2                                    0

   M                                                            M                                  M

P  alt2   Alarm 2    type                                    P  hbu   HB ON/OFF                 P a1of     Alarm 1 OFF delay

      2                                                         on                                     0

   M                                                            M                                  M

P  alt3   Alarm 3    type                                                                       P a2of     Alarm 2 OFF delay

                                                             P  hbl   Heater burnout latch

      2                                                         off                                    0

   M                                                            M                                  M

P  tr-t   Transfer   output  type

                                                             P  hbh   Heater burnout            P a3of     Alarm 3 OFF delay

   off                       Linear output                            hysteresis                       0

   M                                                            0.1

P  tr-h   Transfer   output  upper limit                        M                                  M

                                                             C  st-b  ST stable range           P istp     Input shift type

   100.0

   M                                                            15.0                               ins1

P  tr-l   Transfer   output  lower limit                        M                                  M

   0.0                                                       P  alfa  α

   M                                                            0.65

P  o1-t   Linear current output                                 M

   4-20                                                      P  inf   Input digital filter

   M                           Linear output                    0.0

P  amov   Move to advanced function                             M

          setting level

      0   Displayed when initial setting/

   M      communications protection is             Move  by  setting password (−169).

          set to 0.

                                                                                                                                                                29
E5@Z

Improved Functions

Changes

Model numbers have been changed to allow for universal input     Precautions in Replacing Previous Controllers

specifications.                                                  • Previous E5@Z Controllers cannot be removed from the case for

Before Change                                                    replacement with new models. Replace the case at the same time.

    E5@Z-@@@ (models for thermocouples and platinum resistance

    thermometers)

    None (models for analog input)

    None (models for 24 VAC/VDC)

After Change

    E5@Z-@@@T (models for thermocouples and platinum resistance

    thermometers)

    E5@Z-@@@L (models for analog input)

    E5@Z-@@@@D (models for 24 VAC/VDC)

    The following items have not changed in comparison to the previous E5@Z models: Panel cutout, Internal

    panel dimensions for panel mounting, wiring screw sizes, wiring terminal arrangement, and parameter setting

    methods.

Improved Functions

The previous and new models can be easily differentiated by looking at the front panel. The OMRON logo is in a different position.

                   Item                  Previous models (OMRON logo: lower left)  Improved models (OMRON logo: upper left)

    Front panel

                                         ALM1

                                         ALM2

    E5CZ/E5CZ-U                          HB

                                         OUT1  STOP

                                         OUT2  CMW

    E5AZ

    E5EZ

30
                                                                                                                              E5@Z

Specifications       (Main Changes)

Ratings

          Item                         Previous models                                              Improved models

          E5CZ       7 VA (100 to 240 VAC, 50/60 Hz)                         7.5 VA (100 to 240 VAC, 50/60 Hz)

                     4 VA/3 W (24 VAC, 50/60 Hz or 24 VDC)                   5.5 VA/3.5 W (24 VAC, 50/60 Hz or 24 VDC)

Power     E5CZ-U     (No models with plug-in type)                           6 VA (100 to 240 VAC, 50/60 Hz)

consump-                                                                     4.5 VA/2.5 W (24 VAC, 50/60 Hz or 24 VDC)

tion      E5AZ       9 VA (100 to 240 VAC, 50/60 Hz)                         8.5 VA

                     5 VA/4 W (24 VAC, 50/60 Hz or 24 VDC)                   6 VA/4 W

          E5EZ       9 VA (100 to 240 VAC, 50/60 Hz)                         8.5  VA

                     5 VA/4 W (24 VAC, 50/60 Hz or 24 VDC)                   6 VA/4 W

                                                                             E5@Z-@@@@L@ (Models with analog inputs added.)

Sensor input         (No models with analog inputs)                          Current input: 4 to 20 mA or 0 to 20 mA

                                                                             Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

                     E5CZ-R@@@                                               E5CZ-R@@@@

                     SPST-NO, 250 VAC, 3 A (resistive load)                  SPST-NO, 250 VAC, 3 A (resistive load)

                     Electrical life: 100,000 operations                     Electrical life: 100,000 operations

                                                                             E5CZ-R@@@U

                     (No models with plug-in type)                           SPDT, 250 VAC, 3 A (resistive load)

          Relay                                                              Electrical life: 100,000 operations

                     E5AZ-R@@@                                               E5AZ-R@@@@@

                     SPST-NO, 250 VAC, 5 A (resistive load)                  SPST-NO, 250 VAC, 5 A (resistive load)

                     Electrical life: 100,000 operations                     Electrical life: 100,000 operations

                     E5EZ-R@@@                                               E5EZ-R@@@@@

                     SPST-NO, 250 VAC, 5 A (resistive load)                  SPST-NO, 250 VAC, 5 A (resistive load)

                     Electrical life: 100,000 operations                     Electrical life: 100,000 operations

                     E5CZ-Q@@@                                               E5CZ-Q@@@@

                     12 VDC ±15% (PNP)                                       12 VDC ±15% (PNP)

                     Max. load current: 21 mA                                Max. load current: 21 mA

                     With short-circuit protection                           With short-circuit protection

                                                                             E5CZ-Q@@@U

                     (No models with plug-in type)                           12 VDC ±15% (PNP)

                                                                             Max. load current: 21 mA

Control   Voltage                                                            With short-circuit protection

output 1             E5AZ-Q@@@                                               E5AZ-Q@@@@@

                     12 VDC +15%/−20% (PNP)                                  12 VDC +15%/−20% (PNP)

                     Max. load current: 40 mA                                Max. load current: 40 mA

                     With short-circuit protection                           With short-circuit protection

                     E5EZ-Q@@@                                               E5EZ-Q@@@@@

                     12 VDC +15%/−20% (PNP)                                  12 VDC +15%/−20% (PNP)

                     Max. load current: 40 mA                                Max. load current: 40 mA

                     With short-circuit protection                           With short-circuit protection

                     E5CZ-C@@@                                               E5CZ-C@@@@

                     4 to 20 mA DC                                           4 to 20 mA DC or 0 to 20 mA DC

                     Load: 600 Ω max.                                        Load: 600 Ω max.

                     Resolution: Approx. 2,600                               Resolution: Approx. 2,700

                     E5AZ-C@@@                                               E5AZ-C@@@@

          Current    4 to 20 mA DC                                           4 to 20 mA DC or 0 to 20 mA DC

                     Load: 600 Ω max.                                        Load: 600 Ω max.

                     Resolution: Approx. 2,600                               Resolution: Approx. 2,700

                     E5EZ-C@@@                                               E5EZ-C@@@@

                     4 to 20 mA DC                                           4 to 20 mA DC or 0 to 20 mA DC

                     Load: 600 Ω max.                                        Load: 600 Ω max.

                     Resolution: Approx. 2,600                               Resolution: Approx. 2,700

                                                                             11-segment digital display and single-LED indicator

          E5CZ/CZ-U  7-segment digital display and   single-LED  indicators  (Improved visibility)

Display                                                                      (A 7-segment digital display also possible.)

method                                                                       11-segment digital display and single-LED indicator

          E5AZ/EZ    7-segment digital display and   single-LED  indicators  (Improved visibility)

                                                                             (A 7-segment digital display also possible.)

                                                                             E5@Z-C@@@@

                                                                             Allocated to current output

Transfer output      (No models with transfer outputs)                       4 to 20 mA DC or 0 to 20 mA DC

                                                                             Load: 600 Ω max.

                                                                             Resolution: Approx. 2,700 (4 to 20 mA DC)

                                                                                                                                  31
E5@Z

Other Functions

           Item                          Previous models                                                    Improved models

    Display             ---                                                             Display character switch (7-segment/11-segment)

    Input               Temperature input shift (1-point shift for temperature  input,  Temperature input shift (2-point shift also possible  for

                        2-point shift for no-contact sensor input)                      temperature input)

    Output              ---                                                             Manual outputs

                        ---                                                             Loop break alarm

    Control             Control period: 1 to 99 s                                       Control period: 0.5 or 1 to 99 s

    Alarm               ---                                                             Alarm delays

Characteristics

                 Item                              Previous models                                          Improved models

    Sampling period              500 ms                                                 250 ms

Communications Specifications

                 Item                              Previous models                                          Improved models

    Communications protocols     CompoWay/F (SYSWAY)                                    CompoWay/F (SYSWAY), Modbus

    Baud rate                    1200, 2400, 4800, 9600, 19200 bps                      1200, 2400, 4800, 9600, 19200, 38400 bps

Heater Burnout/Heater Short Alarm Characteristics

           Item                                    Previous models                                          Improved models

                        E5CZ     E5CZ-@2M@ with E53-CNH@N                               E5CZ-@2M@@ with E53-CZH@

                                 Single-phase 50 A AC                                   Single-phase 50 A AC

    Maximum heater               E5@Z-A3 with E53-AZM and E53-AZH

    current             E5AZ/EZ  E5@Z-R3 with E53-AZM and E53-AZH                       E5@Z-@3HM@@

                                 E5@Z-Q3 with E53-AZM and E53-AZH                       Single-phase 50 A AC

                                 Single-phase 50 A AC

    Heater short alarm           ---                                                    Heater short alarm

32
                                                                                                                           E5@Z

Precautions

                              !CAUTION                        Do not allow pieces of metal or wire cuttings to get inside

                                                              connectors. Failure to do so may occasionally result in

Do not touch the terminals while power is being supplied.     minor electric shock, fire, or damage to equipment.

Doing so may occasionally result in minor injury due to

electric shock.                                               Do not allow dust and dirt to collect between the pins in

Do not allow pieces of metal, wire clippings, or fine         the connector on the Conversion Cable. Failure to do so

metallic shavings or filings from installation to enter the   may occasionally result in fire.

product. Doing so may occasionally result in electric         When inserting the body of the Temperature Controller

shock, fire, or malfunction.                                  into the case, confirm that the hooks on the top and

Do not use the product where subject to flammable or          bottom are securely engaged with the case. If the body of

explosive gas. Otherwise, minor injury from explosion         the Temperature Controller is not inserted properly, faulty

may occasionally occur.                                       contact in the terminal section or reduced water

                                                              resistance may occasionally result in fire or malfunction.

Do not leave the conversion cable connected to the            Note: 1.  An SELV circuit is one separated from the power supply

product. Malfunction may occur due to noise in the cable.               with double insulation or reinforced insulation, that does not

                                                                        exceed 30 V r.m.s. and 42.4 V peak or 60 VDC.

Do not use the Temperature Controller or Conversion           2.        A class 2 power supply is one tested and certified by UL as

Cable if it is damaged. Doing so may occasionally result                have the current and voltage of the secondary output

in minor electric shock or fire.                                        restricted to specific levels.

Never disassemble, modify, or repair the product or touch     3.        The tightening torque for E5CZ-U is 0.5 N·m.

any of the internal parts. Minor electric shock, fire, or

malfunction may occasionally occur.

CAUTION - Risk of Fire and Electric Shock

a) This product is UL recognized as Open Type Process

Control Equipment. It must be mounted in an

enclosure that does not allow fire to escape externally.

b) More than one disconnect switch may be required to

de-energize the equipment before servicing the

product.

c) Signal inputs are SELV, limited energy. (See note 1.)

d) Caution: To reduce the risk of fire or electric shock, do

not interconnect the outputs of different Class 2

circuits. (See note 2.)

If the output relays are used past their life expectancy,

contact fusing or burning may occasionally occur.

Always consider the application conditions and use the

output relays within their rated load and electrical life

expectancy. The life expectancy of output relays varies

considerably with the output load and switching

conditions.

Tighten the terminal screws to between 0.74 and

0.90 N·m. Loose screws may occasionally result in fire.

(See note 3.)

Set the parameters of the product so that they are

suitable for the system being controlled. If they are not

suitable, unexpected operation may occasionally result in

property damage or accidents.

A malfunction in the product may occasionally make

control operations impossible or prevent alarm outputs,

resulting in property damage. To maintain safety in the

event of malfunction of the product, take appropriate

safety measures, such as installing a monitoring device

on a separate line.

                                                                                                                                        33
E5@Z

Precautions for Safe Use                                                   18.Always touch a grounded piece of metal before touching the

Be sure to observe the following precautions to prevent malfunction            Temperature Controller to discharge static electricity from your

                                                                               body.

or adverse affects on the performance or functionality of the product.     19.Control output that is voltage output is not isolated from the

Not doing so may occasionally result in faulty operation.                      internal circuits. When using a grounded thermocouple, do not

1.  This product is specifically designed for indoor use only.                 connect any of the control output terminals to ground. (Doing so

    Do not use this product outdoors or in any of the following places:        may result in an unwanted circuit path, causing error in the

    • Places directly subject to heat radiated from heating equipment.         measured temperature.

    • Places subject to splashing liquid or oil atmosphere.                20.When replacing the body of the Temperature Controller, check the

    • Places subject to direct sunlight.                                       condition of the terminals. If corroded terminals are used, contact

    • Places subject to dust or corrosive gas (in particular, sulfide gas      failure in the terminals may cause the temperature inside the

    and ammonia gas).                                                          Temperature Controller to increase, possibly resulting in fire. If the

    • Places subject to intense temperature change.                            terminals are corroded, replace the case as well.

    • Places subject to icing and condensation.                            21.Use suitable tools when taking the Temperature Controller apart

                                                                               for disposal. Sharp parts inside the Temperature Controller may

    • Places subject to vibration and large shocks.                            cause injury.

2.  Use and store the product within the rated ambient temperature         22.Check the orientation of the connectors on the Conversion Cable

    and humidity.                                                              before connecting the Conversion Cable. Do not force a connector

    Gang-mounting two or more Temperature Controllers, or                      if it does not connect smoothly. Using excessive force may

    mounting Temperature Controllers above each other may cause                damage the connector.

    heat to build up inside the Temperature Controllers, which will        23.Do not place heavy object on the Conversion Cable, bend the

    shorten their service life. In such a case, use forced cooling by          cable past its natural bending radius, or pull on the cable with

    fans or other means of air ventilation to cool down the                    undue force.

    Temperature Controllers.                                               24.Do not connect or disconnect the Conversion Cable while

3.  To allow heat to escape, do not block the area around the product.         communications are in progress. Product faults or malfunction

    Do not block the ventilation holes on the product.                         may occur.

4.  Be sure to wire properly with correct polarity of terminals.           25.Make sure that the Conversion Cable’s metal components are not

5.  Use the specified size (M3.5, width 7.2 mm or less) crimped                touching the external power terminals.

    terminals for wiring. To connect bare wires to the terminal block,     26.Do not touch the connectors on the Conversion Cable with wet

    use stranded or solid copper wires with a gage of AWG24 to                 hands. Electrical shock may result.

    AWG14 (equal to a cross-sectional area of 0.205 to 2.081 mm2).         Precautions for Correct Use

    (The stripping length is 5 to 6 mm.) Up to two wires of the same       Service Life

    size and type or two crimp terminals can be inserted into a single

    terminal.                                                              1.  Use the product within the following temperature and humidity

6.  Do not wire the terminals that are not used.                               ranges:

7.  To avoid inductive noise, keep the wiring for the product’s terminal       Temperature: −10 to 55°C (with no icing or condensation)

    block away from power cables carry high voltages or large                  Humidity: 25% to 85%

    currents. Also, do not wire power lines together with or parallel to       If the product is installed inside a control board, the ambient

    product wiring. Using shielded cables and using separate conduits          temperature must be kept to under 55°C, including the

    or ducts is recommended.                                                   temperature around the product.

    Attach a surge suppressor or noise filter to peripheral devices that   2.  The service life of electronic devices like Temperature Controllers

    generate noise (in particular, motors, transformers, solenoids,            is determined not only by the number of times the relay is switched

    magnetic coils, or other equipment that have an inductance                 but also by the service life of internal electronic components.

    component).                                                                Component service life is affected by the ambient temperature: the

    When a noise filter is used at the power supply, first check the           higher the temperature, the shorter the service life and, the lower

    voltage or current, and attach the noise filter as close as possible       the temperature, the longer the service life. Therefore, the service

    to the product.                                                            life can be extended by lowering the temperature of the

    Allow as much space as possible between the product and                    Temperature Controller.

    devices that generate powerful high frequencies (high-frequency        3.  When two or more Temperature Controllers are mounted

    welders, high-frequency sewing machines, etc.) or surge.                   horizontally close to each other or vertically next to one another,

8.  Use this product within the rated load and power supply.                   the internal temperature will increase due to heat radiated by the

9.  Make sure that the rated voltage is attained within 2 seconds of           Temperature Controllers and the service life will decrease. In such

    turning ON the power by using a switch or relay contact. If the            a case, use forced cooling by fans or other means of air ventilation

    voltage is applied gradually, the power may not be reset or output         to cool down the Temperature Controllers. When providing forced

    malfunctions may occur.                                                    cooling, however, be careful not to cool down the terminals

10.Make sure that the Temperature Controller has 30 minutes or                 sections alone to avoid measurement errors.

    more to warm up after turning ON the power before starting actual      Measurement Accuracy

    control operations to ensure the correct temperature display.          1.  When extending or connecting the thermocouple lead wire, be

11.When executing self-tuning, turn ON power to the load (e.g.,                sure to use compensating wires that match the thermocouple

    heater) at the same time as or before supplying power to the               types.

    product. If power is turned ON to the product before turning ON        2.  When extending or connecting the lead wire of the platinum

    power to the load, self-tuning will not be performed properly and          resistance thermometer, be sure to use wires that have low

    optimum control will not be achieved.                                      resistance and keep the resistance of the three lead wires the

12.A switch or circuit breaker must be provided close to the product.          same.

    The switch or circuit breaker must be within easy reach of the         3.  Mount the product so that it is horizontally level.

    operator, and must be marked as a disconnecting means for this         4.  If the measurement accuracy is low, check to see if input shift has

    unit.                                                                      been set correctly.

13.Always turn OFF the power supply before pulling out the interior of     Waterproofing

    the product, and never touch nor apply shock to the terminals or

    electronic components. When inserting the interior of the product,     The degree of protection is as shown below. Sections without any

    do not allow the electronic components to touch the case.              specification on their degree of protection or those with IP@0 are not

14.Do not use paint thinner or similar chemical to clean with. Use         waterproof.

    standard grade alcohol.                                                E5CZ

15.Design the system (e.g., control panel) considering the 2 seconds       E5AZ            Front panel: IP66 (indoor use)

    of delay that the product's output to be set after power ON.           E5EZ            Rear case: IP20, Terminal section: IP00

16.The output may turn OFF when shifting to certain levels. Take this

    into consideration when performing control.                            E5CZ-U          Front panel: Equivalent to IP50, rear case: IP20,

17.The number of EEPROM write operations is limited. Therefore,                            Terminals: IP00

    use RAM write mode when frequently overwriting data during

    communications or other operations.

34
                                                                                                                                             E5@Z

Precautions for Operation                                                    E5EZ/E5AZ

1.  It takes approximately 2 seconds for the outputs to turn ON from                                                Mounting

    after the power supply is turned ON. Due consideration must be                                                  Bracket

                                                                                                                    (Accessory)

    given to this time when incorporating Temperature Controllers in a                                                                Panel

    sequence circuit.

2.  When using self-tuning, turn ON power for the load (e.g., heater)

    at the same time as or before supplying power to the Temperature

    Controller. If power is turned ON for the Temperature Controller

    before turning ON power for the load, self-tuning will not be

    performed properly and optimum control will not be achieved.                      Terminal Cover

3.  When starting operation after the Temperature Controller has                      (E53-COV11)

    warmed up, turn OFF the power and then turn it ON again at the                    (order separately)

    same time as turning ON power for the load. (Instead of turning the

    Temperature Controller OFF and ON again, switching from STOP

    mode to RUN mode can also be used.)

4.  Avoid using the Controller in places near a radio, television set, or

    wireless installing. These devices can cause radio disturbances                     Waterproof packing          E5EZ

    which adversely affect the performance of the Controller.                           (Accessory)

USB-Serial Conversion Cable                                                                                                 Mounting

1.  The disk that is included with the Conversion Cable is designed for                                                     Bracket          Panel

    a computer CD-ROM driver. Never attempt to play the disk in a                                                           (Accessory)

    general-purpose audio player.

2.  Do not connect or disconnect the Conversion Cable connector

    repeatedly over a short period of time. The computer may

    malfunction.

3.  After connecting the Conversion Cable to the computer, check the

    COM port number before starting communications. The computer

    requires time to recognize the cable connection. This delay does                  Terminal Cover

    not indicate failure.                                                             (E53-COV11)

4.  Do not connect the Conversion Cable through a USB hub. Doing

    so may damage the Conversion Cable.

5.  Do not use an extension cable to extend the Conversion Cable

    length when connecting to the computer. Doing so may damage

    the Conversion Cable.

6.  For models with communications, the same port is used by the                                                             E5AZ

    Setting Tool port and for communications via the communications                     Waterproof packing

    terminals. Do not use communications via the communications                         (Accessory)

    terminals when using the Setting Tool port.                              1.  For waterproof mounting, waterproof packing must be installed on

Mounting                                                                         the Controller. Waterproofing is not possible when group mounting

Mounting to the Panel                                                            Controllers. Waterproof packing is not necessary when there is no

                                                                                 need for the waterproof function.

E5CZ                                                                         2.  Insert the E5AZ/E5EZ into the square mounting hole in the panel

                                        Order the P2CF-11 or                     (thickness: 1 to 8 mm). Attach the Mounting Brackets provided

                                        P3GA-11 Socket separately.               with the product to the mounting grooves on the top and bottom

                                                                                 surfaces of the rear case.

      Terminal Cover                                                         3.  Use a ratchet to alternately tighten the screws on the top and

      E53-COV17                                                                  bottom Mounting Brackets little by little to maintain balance, until

      (order separately)                                                         the ratchet turns freely.

                    Adapter                                                  Mounting the Terminal Cover

                    (order separately)                                       For the E5CZ, make sure the “UP” characters on the Cover are in the

                                                                             correct position and insert the Cover into the holes at the top and

                                                                             bottom.

                                                                             For the E5EZ or E5AZ, fit the E53-COV11 Terminal Cover over the

                                                                             upper hook. Mount it in the direction shown in the above diagram. If

                                                 E5CZ-U                      the Terminal Cover is mounted in the opposite direction, proper

                                                                             mounting of the fixtures may not be possible.

Waterproof packing                       For Front-mounting Socket

(Accessory)                              (Panel mounting is also possible.)

             Panel           E5CZ

1.  For waterproof mounting, waterproof packing must be installed on

    the Controller. Waterproofing is not possible when group mounting

    Controllers. Waterproof packing is not necessary when there is no

    need for the waterproof function.

    There is no waterproof function for the E5CZ-U.

2.  Insert the E5CZ/E5CZ-U into the mounting hole in the panel.

3.  Push the adapter from the terminals up to the panel, and

    temporarily fasten the E5CZ/E5CZ-U.

4.  Tighten the two fastening screws on the adapter. Alternately

    tighten the two screws little by little to maintain a balance. Tighten

    the screws to a torque of 0.29 to 0.39 N·m.

                                                                                                                                                       35
E5@Z

Removing the Temperature Controller from the

Case

E5CZ/EZ/AZ

The Temperature Controller can be removed from the case to perform

maintenance without removing the terminal leads. This is possible for

only the E5CZ, E5AZ, and E5EZ, and not for the E5CZ-U. Check the

specifications of the case and Temperature Controller before

removing the Temperature Controller from the case.

                                               Flat-blade screwdriver

                                               (Unit: mm)

                             (1)                                     20 min.

                             (2)

                             (3)                      0.4    2.0

                             (1)

      E5CZ/CZ-U

                                                                              (1)

                             (1)

                             (2)                                              (2)

                             (3)                                              (3)

                             (1)                                              (1)

            E5EZ                                      E5AZ

1.  Insert a flat-blade screwdriver into the two tool insertion holes (one

    on the top and one on the bottom) to release the hooks.

2.  Insert the flat-blade screwdriver in the gap between the front panel

    and rear case, and pull out the front panel slightly. Hold the top and

    bottom of the front panel and carefully pull it out toward you,

    without applying unnecessary force.

3.  When inserting the E5CZ/EZ/AZ, check to make sure that the

    sealing rubber is in place and push the E5CZ/EZ/AZ toward the

    rear case until it snaps into position. While pushing the E5CZ/EZ/

    AZ into place, push down on the hooks on the top and bottom

    surfaces of the rear case so that the hooks are securely locked in

    place. Be sure that electronic components do not come into

    contact with the case.

Precautions when Wiring

    • Separate input leads and power lines in order to prevent external

    noise.

    • Use wires with a gage of AWG24 (cross-sectional area:

    0.205 mm2) to AWG14 (cross-sectional area: 2.081 mm2) twisted-

    pair cable (stripping length: 5 to 6 mm).

    • Use crimp terminals when wiring the terminals.

    • Tighten the terminal screws to a torque of 0.74 to 0.90 N·m.

    • Use the following types of crimp terminals for M3.5 screws.

                                         7.2 mm max.

                                         7.2 mm max.

    • Do not remove the terminal block. Doing so may result in

    malfunction or failure.

36
Digital Position-Proportional Controllers

E5EZ-PRR

A position proportional control model for the E5EZ-

PRR series

• Depth of only 78 mm.

• Various temperature inputs (thermocouple, platinum resistance thermometer,

infrared temperature sensor, voltage inputs) and analog inputs (current, voltage)

• Makes use of high-visibility LCD, with three lines of 4-digit display, for simplicity

and clarity

• 3 lines of display to observe PV/ SV/ MV (valve open percentage), clearly

displaying the state of control (operations)

• Event input enables multi-SP selection and run/ stop function

• Alarm delay function

• Communications function

• Able to choose closed/floating control. In floating control,

position proportional control can be performed without a potentiometer

• Equipped with a manual output function (equipped with an automatic/manual key)

• CE marking and UL/CSA certification

Note: Refer to Precautions on page 59.

Model Number Structure

Model Number Legend

E5EZ-PRR@@@

        1    2  3  4  5  6

1. Control method                   4. Number of alarms                      5. Option                  6.        Input Type

P: Valve control                           Blank: Not available                 Blank: Not available          T: Temperature

2. Control output 1                        2:  Two alarms                       01:     RS-232C               L: Analog input (current, voltage)

R: Relay (OPEN)                                                                 03:     RS-485

3. Control output 2                                                             B:      2 event inputs

R: Relay (CLOSE)

Ordering Information

                      Power supply                  Control                  Number of  Communica-

Size                     voltage        Input type  method                   alarms             tions   Event input           Model

                                                                                        function

                                                                          None                          None         E5EZ-PRRT

                                                                                        None                         E5EZ-PRR2T

                                    Temperature                                                         2 points     E5EZ-PRR2BT

                                    Input Type                            2

                                                                                        RS-232C         None         E5EZ-PRR201T

1/8DIN                100 to                                                            RS-485                       E5EZ-PRR203T

48 × 96 × 78          240 VAC                       Valve        Control  None                                       E5EZ-PRRL

(W × H × D)                                                                                             None

                                    Analog                                              None                         E5EZ-PRR2L

                                    (Current,                                                           2 points     E5EZ-PRR2BL

                                    Voltage) Input                        2

                                    Type                                                RS-232C         None         E5EZ-PRR201L

                                                                                        RS-485                       E5EZ-PRR203L

Accessories (Order Separately)

Unit Label                                                                      Terminal Cover

Model                             Y92S-L1                                       Connectable models      Terminal block models

                                                                                Model                   E53-COV18

                                                                                                                                                  37
E5EZ-PRR

Input Range

Thermocouples / Platinum Resistance Thermometer

    Input type                    Platinum resistance                                                    Thermocouple                                                  ES1B Infrared       Analog input

                                        thermometer                                                                                                                temperature sensor

                                                                                                                                                                   10  60   115       140
                                                                                                                                                                   to  to   to        to
    Name                                Pt100          JPt100               K            J            T         E    L            U          N   R     S     B     70°C 120°C 165°C 260°C  0 to 50 mV

                            1800                                                                                                                             1800

                            1700                                                                                                                 1700  1700                                Usable in the

                            1600                                                                                                                                                           following ranges

                            1500                                                                                                                                                           by scaling:

    Temperature range (°C)  1400                                      1300                                                                1300                                             −1999 to 9999 or

                            1300                                                                                                                                                           −199.9 to 999.9

                            1200

                            1100

                            1000

                            900   850                                              850                               850

                            800

                            700                                                                                 600

                            600         500.0          500.0                500.0

                            500                                                          400.0  400      400.0              400   400.0

                            400

                            300                                                                                                                                                       260

                            200                                                                                                                                             165

                            100                 100.0          100.0                                                                                               70  120            140

                            0                                                                                                                                100            115

                                                0.0            0.0          −20.0        −20.0                  0                                0     0           10  60

                            −100                                                   −100                              −100

                            −200  −200  −199.9         −199.9         −200                      −200  −199.9                −200  −199.9  −200

    Setting number                0     1       2      3       4      5        6   7        8   9        22     10   11     12       23      13  14    15    16    17  18   19        20   21

The applicable standards for each of the above input ranges are as follows:

K, J, T, E, N, R, S, B: JIS C1602-1995, IEC 584-1

L:                                              Fe-CuNi, DIN 43710-1985

U:                                              Cu-CuNi, DIN 43710-1985

JPt100:                                         JIS C 1604-1989, JIS C 1606-1989

Pt100:                                          JIS C 1604-1997 IEC 751

Models with Analog Inputs

    Parameters                                                                           Current [mA]                             Voltage [V]

                                                                                      4 to 20         0 to 20        1 to 5          0 to 5         0 to 10

    Set value                                                                               0            1               2                3            4

    Minimum Setting Unit (Set Value, Alarm)                                        (Scaling, according to the location of the decimal point)

    indicates factory settings.

Optional Functions

                                  Type                                                          Performance

                               RS-232C                    Baud Rate: 1200/2400/4800/9600/19200bps

                               RS-485

                               Event Input                ON: Maximum of 1 KΩ                  OFF: Minimum of 100 KΩ

38
                                                                                                                          E5EZ-PRR

Specifications

Ratings

Power supply voltage                100 to 240 VAC, 50/60 Hz

Operating voltage range             85% to 110% of rated supply voltage

Power consumption                   10 VA (10 W)

                                    Temperature input type

                                    Thermocouple: K, J, T, E, L, U, N, R, S, B

                                    Platinum resistance thermometer: Pt100, JPt100

Sensor input                        Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140    to  260°C

                                    Voltage input: 0 to 50 mV

                                    Analog (current, voltage) input type

                                    Current input: 4 to 20 mA, 0 to 20 mA

                                    Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V

Control output       Relay output   SPST-NO, 250 VAC 1A (resistive load)

                     (OUT1,OUT2)    Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA

Potentiometer input                 100 Ω to 2.5 KΩ

Alarm output                        SPST-NO, 250 VAC 2 A (resistive load)

                                    Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA.

                     Contact input  ON: 1 kΩ max., OFF: 100 kΩ min.

Event input          Non-contact    ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                     input

                                    Outflow current: Approx. 7 mA per point

Control method                      2-PID control

Setting method                      Digital setting using front panel keys

Indication method                   7-segment digital display and single-lighting indicators

                                    Character height: PV: 9 mm; SV: 7 mm; MV: 6.8 mm

Other functions                     According to controller model

Ambient operating temperature       −10 to 55°C (with no icing or condensation)

Ambient operating humidity          25% to 85%

Storage temperature                 −25 to 65°C (with no icing or condensation)

Communications Specifications

Transmission line connection        RS-485:      Multidrop

                                    RS-232C:Point-to-point

Communications method (See          RS-485 (two-wire, half duplex)/RS-232C

note 1.)

Synchronization method              Start-stop synchronization

Baud rate                           1,200/2,400/4,800/9,600/19,200 bps

Communications code                 ASCII

Data length (See note 2.)           7 or 8 bits

Stop bits (See note 2.)             1 or 2 bits

Error detection                     Vertical parity (none, even, odd)

                                    Block check character (BCC)

Flow control                        Not available

Interface                           RS-485/RS-232C

Retry function                      Not available

                                                                                                                                    39
E5EZ-PRR

Specifications

Characteristics

                              Thermocouple:

                              (±0.5% of indicated value or ±1°C, whichever is greater) ±1   digit    max.  (See        note  1.)

    Indication accuracy       Platinum resistance thermometer:

                              (±0.5% of indicated value or ±1°C, whichever is greater) ±1   digit    max.

                              Analog Input: ±0.5% FS ±1 digit max.

                              Potentiometer Input: ±5% FS ±1 digit max.

    Influence of temperature

    (See note 2.)             R, S, and B thermocouple inputs:

    Influence of voltage      (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

    (See note 2.)             Other thermocouple inputs:

                              (±1% of PV or ±4°C, whichever is greater) ±1 digit max.

                              *±10°C for -100°C or less for K sensors

                              Platinum resistance thermometer inputs:

                              (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

                              Analog inputs:

                              (±1% of FS) ±1 digit max.

    Proportional band (P)     0.1 to 999.9 EU (in units of 0.1 EU)

    Integral time (I)         0 to 3999 s (in units of 1 s)      With floating control, 1 to 3999 s

    Derivative time (D)       0 to 3999 s (in units of 1 s)

    Control period            1 to 99 s (in units of 1 s)

    Manual reset value        0.0% to 100.0% (in units of 0.1%)

    Alarm setting range       −1999 to 9999 (decimal point position depends on input type)

    Sampling period           500 ms

    Insulation resistance     20 MΩ min. (at 500 VDC)

    Dielectric strength       2000 VAC, 50 or 60 Hz for 1min (between terminals of different charge)

    Vibration resistance      10 to 55 Hz, 20 m/s2 for 10min each in X,Y, and Z directions

    Shock resistance          100 m/s2, 3 times each in X, Y, and Z directions

    Weight                    Approx. 260 g

    Memory protection         EEPROM (non-volatile memory) (number of writes: 100,000 operations)

                              Emission enclosure:                   EN55011 (GB/T 6113.1, 2)         1 group, type A

                              Emission AC mains:                    EN55011 (GB/T 6113.1, 2)         1 group, type A (See note 2.)

                              Immunity ESD:                         IEC61000-4-2 (GB/T 17626.2)      4 kV contact discharge (series 2)

                                                                                                     6 kV air discharge (series 3)

    EMC

                              Immunity RF interference:             IEC61000-4-3 (GB/T 17626.3):     10 V/m, 80 MHz-1 GHz (series)

                              Immunity-conducted disturbance:       EC61000-4-6 (GB/T 17626.6):      3 V(0.15-80 MHz) (series 3)

                              Surges (shocks):                      IEC61000-4-5 (GB/T 17626.5):     2 kV power supply line (series 3)

                                                                                                     1 kV I/O signal line (series 4)

    Approved standards        UL61010C-1,CSA C22.2 No.1010.1

    Conformed standards       EN61326, EN61010-1 (IEC61010-1)

Note: 1.     The indication accuracy of K thermocouples in the −200 to 1300°C range, T and N thermocouples at a temperature of −100°C max., and

             U and L thermocouples at any temperature is ±2°C ±1 digit maximum. The indication accuracy of the B thermocouple at a temperature

             of 400°C max. is not specified. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit

             max.

         2.  For E5EZ-PRR@03-model products, in order to satisfy the conduction and emission specifications of EN61326CLASSA, a magnetic ring

             (TDK: ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller.

40
                                                                                                                                    E5EZ-PRR

Dimensions

Note:   All units are in millimeters unless  otherwise  indicated.

                                                                                                Panel  Cutout

                                                                         Mounted Separately                    Group Mounted

                                                                                        45             (48     ×  number  of  units  −2.5)  +1.0

                                                                                                                                                0

                                                                                            92

                                                                                                                                            92

                                                                             above 120                 • Recommended panel thickness is 1 to 8 mm.

                                                                                                       • Group mounting is not possible in the vertical

                                                                                                       direction. (Maintain the specified mounting

                                                                                                       space between Controllers.)

                                                                                                       • When two or more Controllers are mounted,

                                                                                                       make sure that the surrounding temperature

                                                                                                       does not exceed the allowable operating

                                                                                                       temperature specified in the specifications.

Package Content

1 Temperature Gauge

2 Metallic Components For Installation

1 Operating Manual

1 Quality Certificate

During removal, please use a screwdriver

to remove the clips on the top and bottom

of the front covering panel, and then

remove the temperature gauge's front

panel.

Accessories

Unit Labels (Order Separately)                                           Terminal Covers (Order Separately)

Y92S-L1 Type                                            11.8             E53-COV18 (Available only for E5EZ-PRR)

                                                                    4.8                                3

                                                                         91

                                                                                            44

                                                                                                                                                         41
E5EZ-PRR

Wiring Terminals

    • Standard insulation is applied to the temperature gauge's I/O sections. If reinforced insulation is required, connect the input and output terminals

    to a device without any exposed current-carrying parts, or to a device with standard insulation suitable for the maximum operation voltage of

    the power supply I/O section.

    • For E5EZ-PRR@03-model products, in order to satisfy the conduction and emission specifications of EN61326CLASSA, a magnetic ring (TDK:

    ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller.

E5EZ-PRR

                                                                                                                   Event Input          Communications                 Communications

                                                                                                                   EV1                      RS232C                         RS485

                                                                          1                                   12                        12          SD                 12     B(+)

    100  to 240 VAC                      50/60 Hz                         2                                   13   EV2                  13          RD                 13

                                                                          3                                   14                        14          SG                 14     DO NOT

                           Control Output 1 (OPEN Output)                 4                                                                                                   USE

                           Control Output 2 (CLOSE Output)

                                                                          5

                                                     OPEN                 6

            Potentiometer                            WIPE                 7

                                                     CLOSE                8

                                                                       A

                           +                    DO NOT     DO NOT         9                                   20

                           mA                   USE        USE         B                                                Alarm     Output 2

                                                                          10                                  21

                                     DO NOT  V                         B                                          Alarm Output 1

                                     USE     +          +                 11                                  22

                           Analog Input                 TC         Pt

Nomenclature

E5EZ-PRR

                                                                   Temperature Unit

                                                                       The temperature unit is displayed when parameters are set to display a temperature.

                                                                       The display is determined by the currently selected "temperature unit" parameter set value.

                                                                       c indicates  °C and f indicates  °F.

                           Operation Indicators

    1. ALM1 (alarm 1)                                                                                                           No. 1 Display

    Lights when alarm 1 output is ON.                                                                                           Displays the process value or parameter type.

    ALM2 (alarm 2)                                                                                                              Lights for approximately one second during startup.

    Lights when alarm 2 output is ON.                                                                              PV

    2. OUT1, OUT2 (control output 1, control output 2)                                                                          No. 2 Display

    Lights when control output 1 or control output 2                                                                              Displays the set point, parameter operation read

    is ON.                                                                                                         SV             value, or the variable input value.

    3. STOP (Stop)                                                                                                                Lights for approximately one second during startup.

    Lights when operation is stopped.

    During operation, this indicator lights when                                                                                No. 3 Display

    operation is stopped by an event or by using the                                                               MV           Displays valve open percentage when valve opening

    RUN/STOP function.                                                                                                          display is on.

    4. CMW (Communications Writing Control)                                                                                     Nothing will be displayed when valve opening display

    Lights when communications writing is enabled                                                       MANU                    is switched off.

    and is not lit when it is disabled.

    5. MANU (Manual Mode)                                                                                                       Up Key

    Lights when the auto/manual mode is set to                                                                                    Each press of this key increments the value displayed

    manual mode.                                                                                                                  on the No. 2 display or advances the setting. Holding

                                                                                                                                  the key down speeds up the incrementation.

                                                Mode Key

            Press this key to change parameters

            within a setting level.

                                                Level Key                                                    A                  Automatic/ Manual Key

            Press this key to move between setting                                                              M                 Press this key for at least one second to switch

            levels. The setting level is selected in                                                                              between automatic and manual mode.

            the following order: operation level:

            adjustment level, initial setting level,

            communications setting level.

                                                                                     Down Key

                                                                                     Each press of this key decrements values displayed on the No. 2 display or

                                                                                     reverses the setting. Holding the key down speeds up the decrementation.

42
                                                                                                                                                    E5EZ-PRR

Operation

Initial hardware setup, including the sensor input type, alarm types, control periods, and other settings is done using parameter displays. The     O

and M keys are used to switch between parameters, and the amount of time that you press the keys determines which parameter you move                to.

Two typical examples are described as follows.

Explanation of Examples

Changing Parameters

in-t                                            A       image means that there

                                                are parameters.

0                       in-h                    Continue pressing the M key

l.ini                                           to change parameters until you

                        100                     reach the intended parameter.

M                       l.ini    M

                                            Changing Numbers

                        in-l                c   25      Numeric data and

                              0                         selections in each screen

intl                    l.ini    M                 0    can be changed by using

                                                100. 0  the U and D keys.

onof

l.ini

                        intl

                        onof

                        l.ini

Typical Example 1

                                                        Setup Procedure

Input Type     : 5K thermocouple −200°C to 1300°C                Power ON                             Power ON

Control Method : PID Control

Alarm 1 Type   : 2 upper limit (deviation)                                         Operation level

Alarm Value 1  : 20°C (deviation)                                                                         c  25

Set value      : 100°C                                                                                       0        Process value/set

                                                                                                             100. .0  value/valve open

                                                                                                                      percentage

                                                                                                                      Press the L key for       at
                                                                                                                      least 3 seconds
                                            Initial setting level
                                                                                                                      Control stops.

                                                                                   Initial setting level

                                                                                   Check input type.         in-t     Input type 5

                                                                 Set input                                   5

                                                        specifications                                       l.ini

                                                                                                             M

                                                                 Set control                                 alt1     Alarm 1

                                                        specifications             Check alarm type.         2

                                                                                                             l.ini    Alarm 2

                                                                                                             M

                                                                 Set alarm

                                                                   type

                                                                                                                      Press the L key for at

                                                                                                                      least 1 second

                                                                                                                      Control starts.

                                                                                   Operation level

                                                                                   Use the U and          c  25       Process value/set value/

                                                                                   D keys to set             100      valve open percentage

                                                                                   the SP to 100°C.          100. .0  100 C

                                                                                                             M

                                                                                                             r-5      Running run

                                                                                   Confirm that              run

                                                                                   control is                l.ini    Stopped stop

                                                                                   running.

                                                Operation level                                              M

                                                                                   Use the U and          c  al-1     Alarm value 1:         20

                                                                 Set alarm         D keys to set             20

                                                                 values            the alarm value

                                                                                   to 20°C.                  l.ini

                                                                                                             M

                                                        Start operation                              Start operation

                                                                                                                                                              43
E5EZ-PRR

Typical Example 2

    Input type    : 9T thermocouple −200°C to 400°C

    Control method : PID control

    Calculate PID constants by AT (auto-tuning).

    Alarm 1 type  : 2 upper limit

    Set value     : 150°C

               Setup Procedure

                  Power ON                                                      Power ON

                                                              Operation level

                                                                                     c     25       Process value/

                                                                                           0        set value/valve

                                                                                           100. .0  open

                                                                                                    percentage

                                                                                           Press the L key for
                                                                                           at least 3 seconds
    Initial setting level
                                                                                                    Control stops.
                                                              Initial setting level

                   Set input                                  Use the U and             in-t

                  specifications                              D keys to select             9        Input type       9

                                                              the input type.              l.ini

                                                                                           M

                  Set alarm type                              Check the                 alt1

                                                              alarm type.                  2        Alarm 1 type: 2

                                                                                           l.ini

                                                                                           M

                                                                                           Press theLkey for
                                                                                           at least 1 second
                                   PV/SP             25       Operation level

                                   after AT is       100      Use the U              c     25       Process value/

                                   stopped           100. .0  and D keys to                         set value/valve

                                                              set the SP to                150      open

                                   The set                    150°C.                       100. .0  percentage 150

                                   point flashes     25

    Adjustment    level            during            100                                   Press the L key for
                                                                                           less than 1 second
                                                     100. .0  Adjustment level
                                   auto-tuning

                                   (AT)                                                    at

                  AT execution     execution.                 Execute AT.                  off      Execute AT:     ON

                                                                                           l. adj   Cancel AT:      OFF

                                   After AT is       at

                                   stopped           off                                   Press the L key for

                                                     l. adj                                less than 1 second

                                                              Operation level                       Control starts

                                   During AT         at                              c     25       Process value/

    Operation     level            execution         on       Confirm that                 150      set value/

                                                     l. adj   the set point is             100. .0  valve open

                                                              150°C.                                percentage

                  Set alarm value                                                          M

                                                                                           r-5      Running

                                                              Confirm that                          run

                                                              control is                   run

                                                              running.                              Stopped

                                                                                                    stop

                                                                                           M

                                                              Use the U and             c  al-1

                                                              D keys to set                30       Alarm           30

                                                              the alarm value                       value 1

                                                              to 30°C.

                  Start operation                                                          M

                                                                                Start operation

44
                                                                                                                                                                    E5EZ-PRR

Setting Level Configuration and Key Operations

Parameters are divided into groups, each called a “level.” Each of the set values (setup items) in these                               levels  are called a “parameter.”

The parameters on the E5EZ-PRR are divided into the following seven levels:

                                                Power ON

          Started in manual mode                               Started in automatic mode

              Press the A key

              for at least 1 s.

                                                Operation Level                        Adjustment Level                                                  L+ M key:

                                                                                                                                                         PV display flashes

                                                                       Press L   key                                   Press the

                                                                       less than 1 s.                                  L+M

                                                                                                                       keys                    c         25

                                 Press the      Press the                                      Press the L key         for at least 1  s.                100

                                 A key for      L key for                          c   25      for at least 1 s;

                                 at least 1 s.  at least 1 s.                                  display will flash.                                    100. 0

Manual                                                                                 100     Press the L key for

                                                                                       100. 0  at least 3 s.                                             L*+ M key

Mode                                                                See note 1.                Control stops.                                            for at least 3 s

                                                                                                                             See note 2.

          Manual                                Initial Setting Level                               Communications

          Control Level                                                                             Setting Level                      Protect Level

                                                                                   Press L key

                                                                                   less than 1 s.

                                                Press L key                      Input password.

                                                for at least 1 s.                Set value −169

                                                                                                                    *  The time taken to move to the

                                                                                                                       protect level can be adjusted by

                                                                    Advanced Function                                  changing the "Move to protect level

                                                                                                                       time" setting.

                                                                    Setting Level

                                                                                                                             Control in progress

                                                                                                                             Control stopped

                                                                                                                             Not displayed for some models

                                                                                                                             Level change

Note: 1.  When returning from the initial setting level to the operation level, the

          default in the operation level will be displayed.

2.        When returning from the protect level to the operation level, the

          default in the operation level will be displayed.

                                                               Control in Progress             Control Stopped

Protect level                                                  Can be set.                     ---

Operation level                                                Can be set.                     ---

Adjustment level                                               Can be set.                     ---

Manual control level                                           Can be set.                     ---

Initial setting level                                          ---                             Can be set.

Advanced function setting level (See note.)                    ---                             Can be set.

Communications setting level                                   ---                             Can be set.

Note: Set the parameters in the “initial setting/communications protect” under “protect level” to “0”, to activate advanced function setting level.

Of these levels, the initial setting level, communications setting level, and advanced function setting level can be used only when control has

stopped. Note that controller outputs are stopped when any of these three levels are selected.

With the exception of operation level, the present level will be displayed. No. 3 display will show the following when settings are being

changed:

              No. 3 Display                                    Level name

      Manual MV                                 Manual control level

      l.prt                                     Protect level

      No display                                Operation level

      la. dj                                    Adjustment level

      l.ini                                     Initial setting level

      l.com                                     Communications setting level

      la. dv                                    Advanced function setting level

                                                                                                                                                                              45
E5EZ-PRR

Descriptions of Each       Level

    Protect Level                    •  To select this level, simultaneously press the L and M keys for

                                        at least 3 seconds. This level is to prevent unwanted or acciden-

                                        tal modification of parameters. Protected levels will not be dis-

                                        played, and so the parameters in that level cannot be modified.

    Operation Level                  •  This level is displayed when you turn the power ON. You can

                                        move to the protect level, initial setting level, manual control level

                                        and adjustment level from this level.

                                     •  Normally, select this level during operation. During operation, the

                                        process value and manipulated variable can be monitored, and

                                        the set points, alarm values, and upper- and lower-limit alarms

                                        can be monitored and modified.

    Adjustment Level                 •  To select this level, press the L key for less than one second.

                                     •  This level is for entering set values and offset values for control.

                                        This level contains parameters for setting the AT (auto-tuning),

                                        communications writing enable/disable, hysteresis, multi-SP, in-

                                        put shift values, heater burnout alarm (HBA) and PID constants.

                                        You can move to the top parameter of the operation level, initial

                                        setting level and protect level from here.

    Manual Control Level             •  Pressing the A key under the operation/adjustment level for 1

                                        second or more will activate manual mode, and switch to the

                                        manual control level.

                                        Under manual control, only “process value/set value/valve open

                                        percentage (manual MV)” can be displayed. Under the “process

                                        value/set value/valve open percentage (manual MV)” manual

                                        control level, pressing the A key for 1 second or more will switch

                                        to automatic mode, switch to the operation level, display the de-

                                        fault in the level, and allow manual operation of MV in this mode.

    Initial Setting Level            •  To access this level, press the L key for 3 or more seconds in

                                        the operation level or adjustment level. 1 second later, the PV dis-

                                        play will blink. This level is used to indicate input type and select

                                        control method, control period, direct/reverse operation, and

                                        alarm type. You can move to the advanced function setting level

                                        or communications setting level from this level. Press the L key

                                        for at least 1 second to switch to the operation level. Press the L

                                        key less than 1 second to switch to the communications level.

    Advanced Function Setting Level  •  To activate this level, set the parameters in the “initial setting/

                                        communications protect” under the “protect level” to “0” and then

                                        enter the password (“-169”) in the initial setting level.

                                     •  The initial setting level can be accessed from this level.

                                     •  This level is for setting the automatic display return time, MV lim-

                                        iter, event input assignment, standby sequence, alarm hystere-

                                        sis, and ST (self-tuning).

    Communications Setting Level     •  To select this level, press the L key less than one second in the

                                        initial setting level. When the communications function is used,

                                        set the communications conditions in this level. Communicating

                                        with a personal computer (host computer) allows set points to be

                                        read and written, and manipulated variables to be monitored.

46
                                                                                                          E5EZ-PRR

Setting the Input Type

                        The Controller supports four input types: platinum resistance thermometer, thermocouple, infrared

                        temperature sensor, and analog inputs. Set the input type that matches the sensor that is used. In the

in-t                    product specifications, there are models with thermocouple/resistance thermometer inputs (universal

       Input Types 5    input) and models with analog input. The settings differ depending on the model.

5                       Check to make sure which model you are using.

l.ini                   List of Input Types

                        Input Type      Specifications    Set value                 Input temperature setting range

                                                                   0        −200 to 850 (°C)              / −300 to 1500 (°F)

                        Platinum               Pt100               1     −199.9 to 500.0 (°C)             / −199.9 to 900.0 (°F)

                        Resistance                                 2        0.0 to 100.0 (°C)             / 0.0 to 210.0 (°F)

                        Thermometer                                3     −199.9 to 500.0 (°C)             / −199.9 to 900.0 (°F)

                                               JPt100              4        0.0 to 100.0 (°C)             / 0.0 to 210.0 (°F)

                                                 K                 5        −200 to 1300 (°C)             / −300 to 2300 (°F)

                                                                   6     −20.0 to 500.0 (°C)              / 0.0 to 900.0 (°F)

                                                 J                 7        −100 to 850 (°C)              / −100 to 1500 (°F)

                                                                   8     −20.0 to 400.0 (°C)              / 0.0 to 750.0 (°F)

                                                 T                 9        −200 to 400 (°C)              / −300 to 700 (°F)

                                                                  22     −199.9 to 400.0 (°C)             / −199.9 to 700.0 (°F)

                        Thermocouple             E                10                0 to 600 (°C)         / 0 to 1100 (°F)

                                                 L                11        −100 to 850 (°C)              / −100 to 1500 (°F)

                                                 U                12        −200 to 400 (°C)              / −300 to 700 (°F)

                                                                  23     −199.9 to 400.0 (°C)             / −199.9 to 700.0 (°F)

                                                 N                13        −200 to 1300 (°C)             / −300 to 2300 (°F)

                                                 R                14                0 to 1700 (°C)        / 0 to 3000 (°F)

                                                 S                15                0 to 1700 (°C)        / 0 to 3000 (°F)

                                                 B                16        100 to 1800 (°C)              / 300 to 3200 (°F)

                        Infrared            10°C to 70°C          17                0 to 90 (°C)          / 0 to 190 (°F)

                        temperature     60°C to 120°C             18                0 to 120 (°C)         / 0 to 240 (°F)

                        sensor,         115°C to 165°C            19                0 to 165 (°C)         / 0 to 320 (°F)

                        ES1B            140°C to 260°C            20                0 to 260 (°C)         / 0 to 500 (°F)

                        Analog Input         0 to 50 mV           21        Either of the following ranges, by scaling:

                                                                                    −1999 to 9999 or −199.9 to 999.9

                        The default is  "5"

                                        Input Type       Specifications  Set value  Input temperature setting range

                                        Current        4 to 20 mA        0          Use the following scales based on the

                                        Input          0 to 20 mA        1          range of measurements:

                        Analog Input                   1 to 5 V          2          −1999 to 9999

                        Type            Voltage                                     −199.9 to 999.9

                                        Input          0 to 5 V          3          −19.99 to 99.99

                                                       0 to 10 V         4          −1.999 to 9.999

                        The default is "0"

                                                                                                                                  47
E5EZ-PRR

Alarm Types

    • Alarm outputs are determined by a combination of “alarm type,” “alarm value,” and “alarm hysteresis” alarm output conditions.

    • This section describes the “alarm type,” “alarm value,” “upper-limit alarm” and “lower-limit alarm” parameters.

    alt1     Alarm1  Set                       Type                                                                    Alarm output operation

                     values                                                               When X                       is positive                When X is negative

    2        Type 2  0            Alarm function OFF                                                                               Output OFF

    l.ini            1            Upper-and lower-limit                                       ON                          L     H

                     See note 1.                                                              OFF                                                 See note 2.

                                                                                                                          SP

                                                                                              ON                                X                 ON     X

                     2            Upper-limit                                                 OFF                         SP                      OFF          SP

                                                                                              ON                          X                       ON              X

                     3            Lower-limit                                                 OFF                         SP                      OFF

                                                                                                                                                               SP

                     4                                                                        ON                          L     H

                     See note 1.  Upper-and lower-limit range                                 OFF                         SP                      See note 3.

                     5                                                                        ON                          L     H

                     See note 1.  Upper-and lower-limit with standby sequence                 OFF                                                 See note 4.

                                                                                                                             SP    (See  note 5)

                     6            Upper-limit with standby sequence                           ON                                X                 ON     X

                                                                                              OFF                         SP                      OFF          SP

                     7            Lower-limit with standby sequence                           ON                          X                       ON              X

                                                                                              OFF                                                 OFF          SP

                                                                                                                          SP

                     8            Absolute-value upper-limit                                  ON                             X                    ON           X

                                                                                              OFF                      0                          OFF                0

                     9            Absolute-value lower-limit                                  ON                             X                    ON           X

                                                                                              OFF                                                 OFF

                                                                                                                       0                                             0

                     10           Absolute-value upper-limit with standby sequence            ON                             X                    ON           X

                                                                                              OFF                      0                          OFF                0

                     11           Absolute-value lower-limit with standby sequence            ON                             X                    ON           X

                                                                                              OFF                                                 OFF

                                                                                                                       0                                             0

                     Note  1. Upper and lower-limit values can be set independently for each                                             alarm    type,  and   are

                                  expressed as L and H. The set values are 1, 4, and 5.

                           2. Set value: 1 (Upper-and lower-limit alarm)

                           Case 1              Case 2             Case 3 (Always ON)

                                                                                              H < 0, L <                        0

                                  L  H  SP     SP L    H             L              SP  H

                                  H< 0.L >0    H> 0.L <0                                      H < 0, L >                        0

                                  |H| < |L|    |H| > |L|          H     LSP                        |H| ≥ |L|

                                                                                              H > 0, L <                        0

                                                                                    SP H   L       |H| ≤ |L|

                           3. Set value: 4 (Upper-and lower-limit range)

                           Case 1              Case 2             Case 3 (Always OFF)

                                                                                                  H< 0.L <0

                                  L  H  SP     SP L    H             L  SP              H

                                  H< 0.L >0    H> 0.L <0                                          H< 0.L <0

                                  |H| < |L|    |H| > |L|          H     L SP                       |H| ≥ |L|

                                                                                                  H< 0.L <0

                                                                                    SP H   L       |H| ≤ |L|

                           4. Set value: 5 (Upper-and lower-limit with standby sequence)

                                  • The upper and lower limit alarms described above.

                                  • In cases 1 and 2, if there is significant overlap between the upper and lower limit values

                                  after hysteresis, the alarm will always be OFF.

                                  Examples of case 1 and 2: In case 3, under general conditions, the alarm is turned OFF.

                           5. Set value: 5 (Upper-and lower-limit with standby sequence)

                                  If there are any overlaps in the upper and lower limits for hysteresis, the alarm will always

                                  be OFF.

                                  There are alarm types 1 to 2 (initial setting level), and settings should be made

                                  independently for each alarm.

                                  The default is 2: upper limit.

48
                                                                                                                                                                      E5EZ-PRR

Parameters

Parameters related to setting items for each level are marked in boxes in the following flowchart                        and brief      descriptions are given as required.             After

finishing each setting, press the mode key to return to the beginning of each level.

                                          Power ON

        Started in manual mode                       Started in automatic mode

        Press A key for at least 1 s.

                                          Operation Level                               Adjustment Level                                                      L+ M key:

                                                                                                                                                              PV display flashes

                                                                        Press L key                                      Press the

                                                                        less than 1 s.                                   L+M                               c
                                                                                                                         keys
                                                                                                Press the L key                                               25
                       Press A key for    Press the                                                                      for at least   1 s.
                                                                                                                                                              100
                       at least 1 s.      L key for                         c           25      for at least 1 s;

                                          at least 1 s.                                         display will flash.                                           100. 0

Manual                                                                                  100     Press the L key for

                                                                                        100. 0  at least 3 s.                                                 L*+ M key

Mode                                                         See note 1.                        Control stops.                                                for at least 3 s

                                                                                                                               See note 2.

        Manual                            Initial Setting Level                                      Communications

        Control Level                                                                                Setting Level                      Protect Level

                                                                            Press L             key

                                                                            less than 1 s.

                                          Press L  key                    Input password.

                                          for at least 1 s.               Set value −169

                                                                                                                     *  The time taken to move to the

                                                                                                                        protect level can be adjusted by

                                                             Advanced Function                                          changing the "Move to protect level

                                                                                                                        time" setting.

                                                             Setting Level

                                                                                                                               Control in progress

                                                                                                                               Control stopped

      Note 1:  When returning from the initial setting level to the operation level, the

               default in the operation level will be displayed.                                                               Not displayed for some                 models

         2:    When returning from the protect level to the operation level, the de-                                           Level change

               fault in the operation level will be displayed.

Display

               c       25                 No. 1 Display

                              0           No. 2 Display

                   100 0                  No. 3 Display

                                                                                                               Power ON

                   Press the         key                                  Press the             key                                     Press the  key

                   for at least 1 s                                       for at least 1 s                                              for less than 1 s

Advanced function                                Initial setting level                               Operation level                                                  Adjustment level

setting level                                                             Press the             key                                     Press the  key

                                                                          for at least 3 s                                              for less than 1 s

                                          Note:  To select the advanced function

                                                 setting level, you must input the

                                                 password (−169) in the initial

                                                 setting level.

                                                                                                                                                                                               49
E5EZ-PRR

Parameter Flow

    •  In each level, if you press the mode key on               the  final  parameter, you will return to the parameter        at the top of the level.

       Advanced function setting level                                                                                          Initial setting level

       init                                                                                                                     in-t

           off  Parameter initialization                                     a1lt                                               5         Input type

       l.                                                                        off  Alarm 1 latch                             l.ini

                                                                             l.                                   Activate

                                                                                                                  alarm latch

       en-m     Number of multi-SP                                                                                              in-h

           1    uses                                                         a2lt     Alarm 2 latch                             100       Scaling upper limit

       l.       Select 2 or 4.                                                   off                                            l.ini

                                                                             l.

                Event input assignment 1  Input setting:                                                                        in-l      Scaling lower limit         For analog input

       none                               Multi-SP/RUN/                      prlt     Move to protect level time                0

       l.                                 STOP                                   3                                              l.ini

                                                                             l.

                                                                                                                                dp        Decimal point

       stop     Event input assignment 2                                     sero                                               0

       l.                                                                        off  Input error output                        l.ini

                                                                             l.

       ospu     Multi-SP uses                                                                                                   d-u       Temperature unit °C / °F

           off     on      off                                               cjc      Cold junction                             c         is Celsius, and        is Fahrenheit

       l.                                                                        on   compensation method                       l.ini

                                                                             l.

       rest     Standby sequence reset                                                                                          Csl-h

                Reset conditions after                                                                                          1300      SP upper limit

           a    standby sequence is                                              off  MB command logic switching

       l.       canceled.                                                                                                       l.ini

                                                                             l.                                                                                       Limit the set point

       al1n     Alarm 1 open in alarm                                                                                           Csl-l

           n-o                                                               a1on     Alarm 1                                   -200      SP lower limit

       l.                                                                        0    ON delay                                  l.ini

                                          ON/OFF setting                     l.

                                          of alarm output 1

       Calh1                                                                                                                              Direct / reverse operation

           02   Alarm 1 hysteresis                                           a2on     Alarm 2                                             Direct operation: on-d

       l.                                                                        0    ON delay                                  l.ini     Reverse operation: or-r

                                                                             l.

       al2n     Alarm 2 open in alarm                                                                             Alarm ON/OFF  alt1

           n-o                                                               a1of     Alarm 1                     delays               2  Alarm 1 type

       l.                                     ON/OFF setting                     0    OFF delay                                 l.ini

                                              of alarm output 2              l.                                                                                       Select alarm mode

       Calh2                                                                                                                    alt2      Alarm 2 type

           02   Alarm 2 hysteresis                                           a2of     Alarm 2                                   2

       l.                                                                        0    OFF delay                                 l.ini

                                                                             l.

       alfa     α                                                                                                               clfl      Closed / floating

                2 PID parameters                                                      Additional MV                             flot      Floating: flot

       0.65                                                                      off  for stop/error                                      Closed: clos

       l.                                                                    l.                                                 l.ini

       inf      Input digital filter                                         Cp-db                                              calb      Motor calibration

           00         Set the time constant,                                          Process value dead band                   off       Motor calibration: on

       l.             in units of s                                              0                                              l.ini     Cancel: off

                                                                             l.

                Additional PV display                                                                                           mot

           off        Displayed first in the operation level                          Valve opening display                     30        Travel time

       l.                                                                        on                                             l.ini

                                                                             l.

                Automatic display return time                                                                                             Switch to advanced function setting level

           ret        Automatic return to operation                          oanl     Manual MV                                           To switch to the advanced function

           off        level when the keys on the front                           on   Limits in effect                          0         setting level, the initial setting/

       l.             panel are operated.                                    l.                                                           communications protect parameters

                                                                                                                                          must be set to 0.

50
                                                                                                                                            E5EZ-PRR

Operation level                                             Adjustment level

C                                                              at     AT execute/cancel                                  MV at stop

   25                            Added when                           AT execute: on                                     Hold: hold

           Process value         Additional PV                 off                                                       Open: open

                                 display is ON.                l.adj  AT cancel: off                              l.adj  Close: close

C                                                              cmwt   Communications      writing                        MV at PV error

   25      Process value/                                             Enabled:     on                                    Hold: hold

   0       set value/valve                                     off    Disabled: off                                      Open: open

   1000.   open percentage                                     l.adj                                              l.adj  Close: close

   m-sp                                                     Csp-0                                                 Csprt

   0       Multi-SP set point setting                          0      SP 0                                        off    SP ramp set value

                                                               l.adj                                              l.adj

C sp-m                                                      Csp-1     SP 1                                        ol-h

   0       Set point during  SP  ramp                          0                                                  1000.  MV upper limit

                                                               l.adj                               SP used   by   l.adj                     MV limit value

                                                                                                   Multi-SP

           RUN/STOP                                         Csp-2     SP 2                                        ol-l

           Run: run                                            0                                                  0.0    MV lower limit

           Stop: stop                                          l.adj                                              l.adj

C al-1                                                      Csp-3     SP 3                                        db

        0  Alarm value 1                                           0                                              20     Position proportional dead band

                                                               l.adj                                              l.adj

Cal1h                                  Set either of these  C  in5                                                oc-h

           Alarm value                 parameters              00     Temperature                  1 point shift  0. 8   Open/ close hysteresis

   0       upper-limit 1                                       l.adj  input shift values                          l.adj

Cal1l                                                       Cin5h     Upper-limit

           Alarm value                                         00     temperature shift

   0                                                           l.adj  (When using a Infrared

           lower-limit 1                                              temperature sensor)

                                                                                                   2 point shift

                                                            Cin5l     Lower-limit

Cal-2                                                                 temperature shift

           Alarm value 2                                       00     (When using a

   0                                                           l.adj  Infrared temperature

                                                                      sensor)

Cal2h                                  Set either of these  C  p

           Alarm value                 parameters              80     Proportional band

   0       upper-limit 2                                       l.adj

C al2l                                                         i      Integral time                PID settings

   0       Alarm value                                         233    (Unit: seconds)

           lower-limit 2                                       l.adj

                                                               d      Derivative time

                                                               40     (Unit: seconds)

                                                               l.adj

                                                                                                                                                            51
E5EZ-PRR

    Protect level                  Operation/ Adjustment Protect

                                   The following table shows the relationship between set values and the range of protection.

    oapt   Operation /                     Level                                                    Set value

    0      adjustment protect                                0                            1                      2                          3

    l.prt

                                                PV          Can be displayed       Can be displayed        Can be displayed        Can be displayed

    icpt   Initial setting /                    PV/SP       Can be displayed       Can be displayed        Can be displayed        Can be displayed

    1      communications          Operation                and changed            and changed             and changed

    l.prt  protect                 level                                                                   Cannot be displayed     Cannot be displayed

                                                Others      Can be displayed       Can be displayed        and moving to other     and moving to other

    wtpt                                                    and changed            and changed             levels is not possible  levels is not possible

    off    Setting change protect                                                  Cannot be displayed     Cannot be displayed     Cannot be displayed

    l.prt                          Adjustment level         Can be displayed       and moving to other     and moving to other     and moving to other

                                                            and changed            levels is not possible  levels is not possible  levels is not possible

    keyp   Automatic/ manual       • Parameters are not protected when        the  set value is set to 0.

    off    key protect             • The default is 0.

    l.prt

                                   Initial Setting/ Communications Protect

                                   This protect level restricts movement to the initial setting level, communications setting level, and advanced

                                   function setting level.

                                   Set value      Initial setting level          Communications setting level    Advanced function setting level

                                   0              Movement possible           Movement possible                  Movement possible

                                   1              Movement possible           Movement possible                  Movement not possible

                                   2              Movement not possible       Movement not possible              Movement not possible

                                   • The default is 1.

                                   Setting Change Protect

                                   This protect level restricts key operations.

                                   Set value                                                 Description

                                   OFF            Settings can be changed using key operations.

                                   ON             Settings cannot be changed using key operations. (The protect level settings, however, can be

                                                  changed.)

                                   • The default is OFF.

                                   Automatic/ Manual Key Protect

                                   This protect level restricts key operations.

                                   Set value                                                 Description

                                   OFF            Settings can be changed between automatic and manual mode using A key operations.

                                   ON             Settings cannot be changed between automatic and manual mode using A key operations. (The

                                                  protect level settings, however, can be changed.)

                                   • The default is OFF.

    Communications setting level   Setting Communications Parameters

                                   • Each parameter is enabled when the power is reset.

                                   • Match the communications specifications of the E5EZ-PRR and the host computer. If multiple devices are

    u-no           Communications     connected, ensure that the communications specifications for all devices in the system (except the

    1              Unit number        Communications unit number) are the same.

    l.com

                                       Parameters            Symbol           Set (monitor) values               Settings          Default       Unit

    bps                            Communications            u-no        0 to 99                                                1           None

    96             Baud rate       Unit number

    l.com                                                                                                  1.2, 2.4, 4.8, 9.6,

                                   Baud rate                 bps         1.2, 2.4, 4.8, 9.6, 19.2          19.2                 9.6         Kbps

    len            Data length     Data length               len         7, 8                                                   7           Length

    7                              Stop bits                 sbit        1, 2                                                   2           Bit

    l.com

                                   Parity                    prty        None, even, odd                   none, even, odd      Even        None

    sbit           Stop bits

    2

    l.com

                   Parity

    l.com

52
                                                                                                        E5EZ-PRR

Error Displays

                                   When an error occurs, the error contents are shown on the No.1 display.

                                   This section describes how to check error codes on the display, and the actions

                                   to be taken to remedy the problems.

5.err               Input Error

Meaning                            The input value has exceeded the input indication range(−1999 (−199.9) to

                                   9999 (999.9)).

Action                             Check the wiring of inputs for miswiring, disconnections, and short-circuits and

                                   check the input type.

                                   If no abnormality is found in the wiring and input type, turn the power OFF then

                                   back ON again.

                                   If the display remains the same, the Controller must be replaced. If the display is

                                   restored, then the probable cause is electrical noise affecting the control system.

                                   Check for electrical noise.

Operation at Error                 After an error occurs, the error is displayed and the alarm outputs function as if

                                   the upper limit has been exceeded.

                                   When the “input error output” parameter in the advanced function level is set to

                                   ON, the alarm 1 output turns ON whenever an input error occurs.

                                   An error message is displayed when the PV or PV/SV/valve open percentage is

                                   displayed.

                                   Note. When the manual MV, MV at stop, or MV at PV error is set, the control

                                   output corresponds to the set value.

                    Display Range  Exceeded

Meaning                            Though this is not an error, it is displayed if the process value exceeds the dis-

                                   play range when the control range is larger than the display range.

                                   The display ranges are shown below.

                                   • When less than −1,999 (−199.9)      [[[[

                                   • When more than 9,999       (999.9)  ]]]]

Operation at Error                 Control continues, allowing normal operation. The message is displayed when

                                   the PV or PV/SV/valve open percentage is displayed.

                                                                                                                        53
E5EZ-PRR

    Platinum resistance thermometer input (Except for models with                 Platinum resistance thermometer input (Except for models with

    a setting range of −199.9 to 500.0°C)                                         a setting range of −199.9. to 500.0°C)

    Thermocouple input (Except for models with a setting range of                 Thermocouple input (Except for models with a setting range of

    −199.9 to 400.0°C)                                                            −199.9 to 400.0°C)

    ES1B           Control range                                                                               Control range

    s.err display  Numeric display         s.err display                          s.err display  [[[[ display    Numeric display                  s.err display

                   Input indication range                                                                      Input indication range

    Analog (current, voltage) Input                                                                       Analog Input

    • When display range < control range                                                                  • When display range > control range

                                           Control range                                                                  Control range

    s.err display  [[[[ display            Numeric display                  ]]]]  display  s.err display  s.err display   Numeric display         s.err display

                                           Input indication range                                                         Input indication range

                                 −1999     Display range           9999                                        −1999          Display range       9999

                                 (−199.9)                          (999.9)                                     (−199.9)                           (999.9)

    e111                             Memory Error

    Meaning                                                        Internal memory operation is in error.

    Action                                                         First, turn the power OFF then back ON again. If the display remains the same,

                                                                   the Controller must be repaired. If the display is restored, then the probable

                                                                   cause is electrical noise affecting the control system. Check for electrical noise.

    Operation at Error                                             Control output and alarm output turn OFF.

    ----                         Potentiometer                     Input Error

    Meaning                                                        Valve opening has exceeded its regular range of −10% to 110%.

    Action                                                         Check to see if there have been any wiring errors, burnouts, or short-circuits in

                                                                   the potentiometer.

                                                                   If there are no problems with the wiring, you can restart the power supply. If the

                                                                   display remains the same, the Controller must be replaced. If the display is re-

                                                                   stored, then the probable cause is interference which should be avoided.

    Operation at Error                                             Control output will output MV based on the “MV during error” setting position.

                                                                   Alarm output will operate as normal.

    err                           Motor    Calibration Error

    Meaning                                                        Motor calibration did not completely finish.

    Action                                                         After confirming the potentiometer and the wiring          of the   motor      driving  valve,  per-

                                                                   form motor calibration again.

    Operation at Error                                             Control output and alarm output set to OFF.

54
                                                                                                                              E5EZ-PRR

Position proportional control of a ceramic kiln

The control method whereby a potentiometer is used to read the amount of opening of a valve and then open or close the valve by means of an

attached control motor is called position proportional control or on/off servo control.

Application

                                  To control a gas kiln using a position proportional control valve, select the control valve control type and

                                  configure the instrumentation as shown in the following example.

    Temperature Input

    Analog Input            Potentiometer

                                                             SP

                       PV                                                                SP ramp

                                           SP after change

SP  SP  Ramp

                                                                                                                 SP ramp

                                                                                                                 set value

                       PID

                                                                                                    SP ramp in units of time

                       MV

                                           SP before change

                                                                                                                 Time

        OUT1                OUT2                                   Point of change

                                           E5EZ-PRR

                                                  8888             PV

                                                  8888             SV

                                                  8888             MV

                                                  MANU

                                                             A  M

                                                                                                    Temperature

                                                                                                    Sensor

                                                                                         Burner

                                           Note:             The SP ramp function allows limits to be placed on temperature changes which

                                                             control the temperature within a specific range. This is useful for ceramic kiln,

                                                             in which severe temperature changes may cause damage or corruption.

                                                                                                                                                55
E5EZ-PRR

Wiring

                                       Input should be connected to terminals 9, 10, and 11 depending      on input type. Connect          the  open

                                       side of the position proportional valve to OUT1, and connect the    closed side to OUT2.

                                                                                                           1                      12

                                                                                                           2                      13

                                                                                                           3                      14

                                       Ceramic kiln

                                       (combustion)                                                        4

                                                                      C  W   O

                                                                      CLOSE                                5

                                                           Sensor     OPEN

                                                                      Valve

                                                                                                           6

                                                                                                           7

                                                                                                           8

                                                              Burner  Position proportional  valve         9                      20

                                                                                                           10                     21

                                                                                                           11                     22

Settings

                                       Select the value control type and perform floating control using Position-proportional value with travel

                                       time* of 45 seconds. Set SP ramp to change SP within a width of 10.0°C/minute.

                                       *Time from completely open to completely close.

                                       The related setting data and settings are as follows:

                                       Direct/ reverse operation                             =  or-r: Reverse operation (initial setting)

                                       Closed/ floating                                      =  flot: Floating (initial setting)

                                       Travel time                                           = 45 seconds

                                       SP ramp set value                                     =  "10"

                                       The travel time and SP ramp set value are set in the following, and the initial settings are used for

    in-t                               all other parameters.

    5

    l.ini                              1.  Press the L key for at least 3 seconds to switch from the operation level to the initial setting

                                           level.

            Travel time

    mot

    30                45               2.  Press the M key repeatedly to select "mot: Travel time". Press the U key to set the value to

    l.ini   U                              "45".

    Operation level

            Process value/ set value/

    25      valve open percentage      3.  Press the L key for at least 1 second to return to the “operation level”. When “present value/

    0                 25 0                 set value/valve open percentage” is displayed, press the U key to set the set value to “250”.

    100. 0  U

    Adjustment level

    at                                 4.  Press the L key for less than 1 second to switch from operation level to adjustment level.

    off

    l.adj                              5.  Press the M key repeatedly to select sprt: SP ramp set value. Press the U key, to set the

                                           value to “10”.

    sprt    SP ramp set value

    0                 10

    l.adj   U

56
                                                                                                              E5EZ-PRR

Adjustment                              To adjust the PID constants, run AT.

Settings for position                   When position proportional control is selected, "Closed/Floating", "Motor calibra-

                                        tion", "Travel time", "Position proportional dead band", "Open/Close hysteresis",

proportional control                    "Operation at potentiometer input error", and "PV dead band" can be used.

Closed/Floating                         •  Closed control

                                           Control whereby a potentiometer is connected to feed back the amount of

                                           opening of the valve.

                                        •  Floating control

                                           Control without feedback of the amount of opening of the valve. Control is

                                           possible without connecting a potentiometer.

Motor calibration and travel  time      Run "Motor calibration" when a potentiometer is connected for closed control or

                                        floating control that monitors the amount of valve opening.

                                        This will also automatically set the "Travel time", which is the amount of time from

                                        when the valve is completely open to when the valve is completely closed.

                                        When performing floating control without a potentiometer, it is necessary to man-

                                        ually set the "Travel time". Set the travel time to the amount of time from when

                                        the valve is completely open to when the valve is completely closed.

Position proportional dead band and     The valve output hold interval (the duration of ON/OFF switching of open output

Open/Close hysteresis                   and closed output) is set in "Position proportional dead band", and the hysteresis

                                        is set in "Open/Close hysteresis".

                                        The relation to valve opening is shown below.

                                                                  Open/close hysteresis

                                                                              Dead band

                                           ON

                                           OFF

                                           −100%                                                     MV-Valve opening

                                                                              0                                               100%

PV dead band                            When the present value is inside the PV dead band, this function is used to per-

                                        form control for PV = SP and stop unnecessary output when the PV is close to

                                        the SP.

Operation at potentiometer input error  Use this setting to select whether to stop control or switch to floating control and

                                        continue when a potentiometer error occurs during closed control.

                                                                                                                                    57
E5EZ-PRR

Meeting all of your temperature control needs in a wide range of

applications

ES1B Infrared Temperature Sensor

Perform measurements with a contract-free sensor at minimal costs!

                                    • Outputs electromotive forces identical to those of thermocouples, so that it can be connected

                                    directly to temperature controllers that generally use thermocouple input.

                                    • 4 types of specifications. Can be used in all types of temperature measurements, from food

                                    products, packaging, and finished product, all the way to electrical engineering.

                                    • 300 ms high-speed response (63% response time), ±1% and PV's reenactment capabilities,

                                    ensuring high-accuracy temperature measurements.

                                    • Compared to thermocouples, this product has the advantage of being resistant to aging, and can

                                    maintain steady real-time control.

Note:  For  more  detailed  information, please refer to other ES1B-related materials.

                            Shape, visual features                                           Specifications                    Type

                                                                                         (temperature testing range)

                                    2 mm       20 mm         40 mm  60 mm                    10 to 70°C

                                                                                             60 to 120°C

                                                                                             115 to 165°C

                                                                                                                       ES1B

                                                                                             140 to 260°C

                                    2              20        40     60

ES1-L Series of Infrared Temperature Sensors

Able to measure temperatures without contact.

Damage-free, clean, and effective temperature management.

    • Comes in two spot diameters: 3 mm dia. and 8 mm dia.

    • Recreation accuracy kept within ±0.5°C, with a response speed of 0.4

    seconds (95%), along with high accuracy, realizing fast measurement.

    • In addition to the original unit for use in medium temperatures (0 to

    +500°C), there are new models for use in medium to low temperatures

    (−50 to +500°C) and high temperatures (0 to +1000°C).

    • New long distance types enable measuring from distances of 500 mm and

    1000 mm.

    • By using a programmer (order separately), it is possible to monitor

    temperatures as well as make changes to the rate of emissions, switches

    between functions, and range of output.

    (The picture shows a programmer installed onto an ES1 unit.)

            Type                    Range of temperature            Spot dimensions (See note 2.)                     Type

                                    measurements

    For use with high               0 to +1,000°C            35 mm dia. (distance of 1000 mm)                         ES1-LW100H

    temperatures                                             Below 40 mm dia. (distance of 500 mm)                    ES1-LW50H

    For use with medium to      −50 to +500°C (See note 1.)  35 mm dia. (distance of 1000 mm)                         ES1-LW100

    low temperatures                                         Below 40 mm dia. (distance of 500 mm)                    ES1-LW50

    For use with medium             0 to +500°C              3 mm dia. (distance of 30 mm)                            ES1-LP3

    temperatures                                             8 mm dia. (distance of 100 mm)                           ES1-LP10

Note: 1.   At the time of shipment, the ES1-PRO model's range will have to be changed for

           0 to +500°C, −50°C.

       2.  This value is based on the energy restriction of 90%. The actual item must be at

           least 1.5 times larger.

Note:     For more detailed information, please refer to other ES1-L-related materials.

E52 Series of Temperature Sensors

Providing a diverse array of high-accuracy temperature sensors

    • Used as a sensor for temperature controllers.

    • Guaranteed that clients will be able to easily select the right model according to

    their temperature, location, and ambient operating conditions.

    • Able to provide numerous models of various different categories, cases,

    lengths, and terminal shapes.

    • Able to provide low-cost made-to-order models, as well as models for universal

    use.

Note: For more detailed information, please refer to other E52-related materials.

58
                                                                                                                             E5EZ-PRR

Safety Precautions

                              !CAUTION                                 Precautions for Safe Use

                                                                       Be sure to observe the following precautions to prevent operation

Do not touch the terminals while power is being supplied.              failure, malfunction, or adverse affects on the performance and

Doing so may occasionally result in minor injury due to                functions of the product. Not doing so may occasionally result in

electric shock.                                                        unexpected events.

Operate the Temperature Controller properly. Improper                  1.  The product is designed for indoor use only. Do not use the

operation may cause minor or moderate injury or property                   product outdoors or in any of the following locations.

damage.                                                                    • Places directly subject to heat radiated from heating equipment.

Do not allow pieces of metal, wire clippings, or fine                      • Places subject to splashing liquid or oil atmosphere.

metallic shavings or filings from installation to enter the                • Places subject to direct sunlight.

product. Doing so may occasionally result in electric                      • Places subject to dust or corrosive gas (in particular, sulfide gas

shock, fire, or malfunction.                                               and ammonia gas).

Do not use the product where subject to flammable or                       • Places subject to intense temperature change.

explosive gas. Otherwise, minor injury from explosion

may occasionally occur.                                                    • Places subject to icing and condensation.

Never disassemble, modify, or repair the product or touch                  • Places subject to vibration and large shocks.

any of the internal parts. Minor electric shock, fire, or              2.  Use and store the product within the rated temperature and

malfunction may occasionally occur.                                        humidity ranges.

CAUTION - Risk of Fire and Electric Shock                                  Group-mounting two or more Temperature Controllers, or

a) This product is UL listed as Open Type Process                          mounting Temperature Controllers above each other may cause

Control Equipment. It must be mounted in an                                heat to build up inside the Temperature Controllers, which will

enclosure that does not allow fire to escape externally.                   shorten their service life. In such a case, use forced cooling by

b) More than one disconnect switch may be required to                      fans or other means of air ventilation to cool down the

de-energize the equipment before servicing the                             Temperature Controllers.

product.                                                               3.  To allow heat to escape, do not block the area around the product.

c) Signal inputs are SELV, limited energy. (See note 1.)                   Do not block the ventilation holes on the product.

d) Caution: To reduce the risk of fire or electric shock, do           4.  Use the specified size (M3.5, width of 7.2 mm or less) crimped

             not interconnect the outputs of different Class               terminals for wiring. To connect bare wires to the terminal block,

             2 circuits. (See note 2.)                                     use copper braided or solid wires with a gage of AWG24 to

                                                                           AWG14 (equal to a cross-sectional area of 0.205 to 2.081 mm2).

If the output relays are used past their life expectancy,                  (The stripping length is 5 to 6 mm.) Up to two wires of the same

contact fusing or burning may occasionally occur. Always                   size and type, or two crimp terminals can be inserted into a single

consider the application conditions and use the output                     terminal.

relays within their rated load and electrical life                     5.  Be sure to wire properly with correct polarity of terminals. Do not

expectancy. The life expectancy of output relays varies                    wire any of the I/O terminals incorrectly.

considerably with the output load and switching                        6.  Do not wire the terminals that are not used.

conditions.                                                            7.  The voltage output (control output) is not electrically isolated from

Loose screws may occasionally result in fire.                              the internal circuits. When using a grounded temperature sensor,

Tighten terminal screws to the specified torque of 0.74 to                 do not connect any of the control output terminals to ground.

0.90 N·m.                                                                  Otherwise unwanted current paths will cause measurement

                                                                           errors.

Unexpected operation may result in equipment damage                    8.  To avoid inductive noise, keep the wiring for the Temperature

or accidents if the settings are not appropriate for the                   Controller's terminal block away from power cables carrying high

controlled system. Set the Temperature Controller as                       voltages or large currents. Also, do not wire power lines together

follows:                                                                   with or parallel to Temperature Controller wiring. Using shielded

A malfunction in the Temperature Controller may                            cables and using separate conduits or ducts is recommended.

occasionally make control operations impossible or                         Attach a surge suppressor or noise filter to peripheral devices that

prevent alarm outputs, resulting in property damage.                       generate noise (in particular, motors, transformers, solenoids,

To maintain safety in the event of malfunction of the                      magnetic coils or other equipment that have an inductance

Temperature Controller, take appropriate safety                            component).

measures, such as installing a monitoring device on a                      When a noise filter is used at the power supply, first check the

separate line.                                                             voltage or current, and attach the noise filter as close as possible

                                                                           to the temperature controller.

Be sure that the platinum resistance thermometer type                      Allow as much space as possible between the Temperature

and the input type set on the Temperature Controller are                   Controller and devices that generate powerful high frequencies

the same.                                                                  (high-frequency welders, high-frequency sewing machines, etc.)

                                                                           or surge.

Note: 1.  A SELV circuit is one separated from the power supply with   9.  To reduce the risk of fire or electric shock, install the Temperature

          double insulation or reinforced insulation, that does not        Controller in a controlled environment relatively free of

          exceed 30 V r.m.s. and 42.4 V peak or 60 VDC.                    contaminants.

2.        A class 2 power supply is one tested and certified by UL as  10.The outputs may turn OFF when shifting to certain levels. Take

          having the current and voltage of the secondary output           this into consideration when performing control.

          restricted to specific levels.                               11.When turning OFF the power, use a switch or relay to ensure the

                                                                           voltage decreases immediately. Incorrect operation and data

                                                                           storage errors may occur if the voltage decreases slowly.

                                                                       12.Make sure that any Option Units are installed correctly. Do not

                                                                           remove the internal PCB when installing an Option Unit.

                                                                       13.When inserting the Temperature Controller into the case, do not

                                                                           force it into the case. Doing so will damage internal parts.

                                                                       14.The EEPROM has a limited write life. When overwriting data

                                                                           frequently, e.g., via communications, use RAM Mode.

                                                                       15.Use the product within the rated load and power supply.

                                                                       16.Use a switch, relay, or other contact so that the power supply

                                                                           voltage reaches the rated voltage within 2 seconds. If the applied

                                                                           voltage is increased gradually, the power supply may not be reset

                                                                           or malfunctions may occur.

                                                                                                                                                  59
E5EZ-PRR

17.When using PID operation (self-tuning), turn ON the power supply           Precautions for Correct Use

    to the load (e.g., heater) at the same time or before turning the         Service Life

    power supply to the Temperature Controller ON. If power is turned

    ON for the Temperature Controller before turning ON power                 1.  Use the product within the following temperature and humidity

    supply to the load, self-tuning will not be performed properly and            ranges:

    optimum control will not be achieved.                                         Temperature: −10 to 55°C (with no icing or condensation)

18.Design the system (e.g., control panel) to allow for the 2 seconds             Humidity: 25% to 85%

    of delay required for the Temperature Controller's output to                  If the product is installed inside a control board, the ambient

    stabilize after the power is turned ON.                                       temperature must be kept to under 55°C, including the

19.A switch or circuit breaker should be provided close to this unit.             temperature around the product.

    The switch or circuit breaker should be within easy reach of the

    operator, and must be marked as a disconnecting means for this            2.  The service life of electronic devices like Temperature Controllers

    unit.                                                                         is determined not only by the number of times the relay is switched

20.Approximately 30 minutes is required for the correct temperature               but also by the service life of internal electronic components.

    to be displayed after turning the power supply to the Temperature             Component service life is affected by the ambient temperature: the

    Controller ON. Turn the power supply ON at least 30 minutes prior             higher the temperature, the shorter the service life and, the lower

    to starting control operations.                                               the temperature, the longer the service life. Therefore, the service

21.When extending the thermocouple lead wires, always use                         life can be extended by lowering the temperature of the

    compensating conductors suitable for the type of thermocouple.                Temperature Controller.

    Do not extend the lead wires on a platinum resistance                     3.  When two or more Temperature Controllers are mounted

    thermometer. Use only low-resistance wire (5 Ω max. per line) for             horizontally close to each other or vertically next to one another,

    lead wires and make sure that the resistance is the same for all              the internal temperature will increase due to heat radiated by the

    three wires.                                                                  Temperature Controllers and the service life will decrease. In such

22.When drawing out the Temperature Controller from the case, do                  a case, use forced cooling by fans or other means of air ventilation

    not apply force that would deform or alter the Temperature                    to cool down the Temperature Controllers. When providing forced

    Controller.                                                                   cooling, however, be careful not to cool down the terminals

23.When drawing out the Temperature Controller from the case to                   sections alone to avoid measurement errors.

    replace the Temperature Controller, check the status of the               Measurement Accuracy

    terminals. If corroded terminals are used, contact faults with the

    terminals may cause the temperature inside the Temperature                1.  When extending or connecting the thermocouple lead wire, be

    Controller to increase, possibly resulting in fire. If the terminals are      sure to use compensating wires that match the thermocouple

    corroded, replace the rear case as well.                                      types.

24.When drawing out the Temperature Controller from the case, turn            2.  When extending or connecting the lead wire of the platinum

    the power supply OFF first, and absolutely do not touch the                   resistance thermometer, be sure to use wires that have low

    terminals or electronic components or apply shock to them. When               resistance and keep the resistance of the three lead wires the

    inserting the Temperature Controller, do not allow the electronic             same.

    components to come into contact with the case.                            3.  Mount the product so that it is horizontally level.

25.Static electricity may damage internal components. Always touch            4.  If the measurement accuracy is low, check to see if input shift has

    grounded metal to discharge any static electricity before handling            been set correctly.

    the Temperature Controller. When drawing out the Temperature

    Controller from the case, do not touch the electronic components          Operating Precautions

    or patterns on the board with your hand. Hold the Temperature             1.  It takes approximately two seconds for the outputs to turn ON from

    Controller by the edge of the front panel when handling it.                   after the power supply is turned ON. Due consideration must be

26.Do not use paint thinner or similar chemical to clean with. Use                given to this time when incorporating Temperature Controllers in a

    standard grade alcohol.                                                       sequence circuit.

27.Use tools when separating parts for disposal. Contact with the             2.  When using self-tuning, turn ON power for the load (e.g., heater)

    sharp internal parts may cause injury.                                        at the same time as or before supplying power to the Temperature

                                                                                  Controller. If power is turned ON for the Temperature Controller

                                                                                  before turning ON power for the load, self-tuning will not be

                                                                                  performed properly and optimum control will not be achieved.

                                                                              3.  When starting operation after the Temperature Controller has

                                                                                  warmed up, turn OFF the power and then turn it ON again at the

                                                         &nbs