器件描述

Controllers 2 points: Current / Current

参数

产品属性属性值
产品种类:
Product Category:
Controllers
制造商:
Manufacturer:
Omron
RoHS:YES
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
单位重量:
Unit Weight:
11.640407 oz

E5ER-CT3DW-FLK-AC-DC24器件文档内容

    Digital Controllers

    E5ER

                                                                                                                          CSM_E5ER_DS_E_4_2

E5ER Digital Controllers offer high speed,

high precision, and multiple I/O and use a

5-digit, 3-row LCD display for high visual

clarity.

• A short sampling period of 50 ms enables use in applications

requiring high-speed response.

• PV, SP, and MV data is displayed simultaneously in a 3-row,

negative LCD display with a backlight.

• Multipoint control, cascade control, and proportional control are

possible with a single Controller.

• When using models with CompoWay/F communications, initial

settings can be downloaded and settings can be masked using

Support Software (CX-Thermo version 4.0 or higher).                                  For the most recent information on models that have been certified for

• Equipped with calculation functions as a standard (e.g., square                    safety standards, refer to your OMRON website.

root calculation and broken-line approximation).

• DeviceNet Communications

Data setting and monitoring can be performed without any                             Refer to Safety Precautions for All E5@R

special programming.                                                                 Models.

                                                                           Refer to E5AR/E5ER Operation for operating

                                                                           procedures.

Model Number Structure

■ Model Number Legend

E5ER-@@@@@@@@@-@@@                                                         5.  Auxiliary outputs

                                                                               Blank:None

          1   2  3  4  56  7  8  9     10                                      4:    4PST-NO relay outputs

1.  Constant values/Program                                                    T:    2 transistor outputs

    None: Constant values                                                  6.  Optional function 1

2.  Control method                                                             Blank:None

    Blank: Standard, or heating/cooling control                                3:    RS-485 communications

    P:  Position-proportional control                                      7.  Optional function 2

3.  Output 1                                                                   Blank:None

    R:  DPST-NO relay outputs                                                  D:    4 event inputs

    Q:  Pulse voltage and pulse voltage/current  outputs                   8.  Input 1

    C:  Current and current outputs                                            B:    Universal-input and 2 event inputs

4.  Output 2                                                                   F:    Universal-input and FB

    Blank:None                                                                 W:    Universal-input and universal-input

    R:  Relay                                                              9.  Input 2

    Q:  Pulse voltage and pulse voltage/current  outputs                       Blank:None

    C:  Current and current outputs                                            W:    Universal-input and universal-input

                                                                           10.Communications Method

                                                                               Blank:None

                                                                               FLK:  CompoWay/F

                                                                               DRT:  DeviceNet

Note: The above model number legend is intended as a functional description of models. Not all possible combinations of   functions  are  available.

        Confirm model availability in Ordering Information when ordering.

    The CX-Thermo Support Software (version 4.0 or higher) can be used to easily set parameters in conversational form.

    Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital

        Controller.

        E5AR/E5ER Digital Controller User’s Manual (Cat. No. Z182)

        E5AR/E5ER Digital Controller DeviceNet Communication User’s Manual (Cat. No. H124)

                                                                                                                                                             1
                                                                                                                                E5ER

Ordering Information

■ Digital Controllers

Standard Controllers

Size      Control type                   Control mode                  Outputs (control/            Optional functions          Model

                                                                       transfer)              Auxiliary   Event   Serial

                                                                                                 outputs  inputs  commu-

                                                                                                 (SUB)            nications

48 ×  96  Basic control   Single-loop standard control                 2 points: Pulse volt-  4           2       No            E5ER-Q4B

mm        (1 loop)        Single-loop heating and cooling control      age and Pulse volt-

                                                                       age/current

                                                                       2 points: Current and                                    E5ER-C4B

                                                                       Current

                                                                       2 points: Pulse volt-                      RS-485        E5ER-Q43B-FLK

                                                                       age and Pulse volt-                                      (See note 2.)

                                                                       age/current

                                                                       2 points: Current and                                    E5ER-C43B-FLK

                                                                       Current                                                  (See note 2.)

                                                                       2 points: Pulse volt-  2           6                     E5ER-QT3DB-FLK

                                                                       age and Pulse volt-    (See  note                        (See note 2.)

                                                                       age/current            3.)

                                                                       2 points: Current and                                    E5EAR-CT3DB-

                                                                       Current                                                  FLK (See note 2.)

                                                                       4 points: Pulse volt-  4           2                     E5ER-QC43B-FLK

                                                                       age and Pulse volt-

                                                                       age/current and

                                                                       Current (2 points)

          2-loop control  2-loop standard control                      2 points: Pulse volt-  2           4       RS-485        E5ER-QT3DW-FLK

                          Single-loop heating and cooling control      age and Pulse volt-    (See  note

                          Single-loop cascade control                  age/current            3.)

                          Single-loop control with remote SP           2 points: Current and                                    E5ER-CT3DW-FLK

                          Single-loop proportional control             Current

          Position-pro-   Single-loop position-proportional control    Relay output           2           4       No            E5ER-PRTDF

          portional con-  (See note 4.)                                (1 open, 1 closed)     (See  note

          trol                                                                                3.)

          (1 loop)                                                     Relay output           4           No      RS-485        E5ER-PRQ43F-FLK

                                                                       (1 open, 1 closed)

                                                                       and 1 current (trans-

                                                                       fer) output

Note  1:  Specify the power supply specifications when ordering. Model numbers for 100 to     240 VAC are different from those  for 24 VAC/VDC.

      2.  These models are for 100 to 240 VAC only.

      3.  The auxiliary outputs are transistor outputs.

      4.  Can be switched between close control and floating control.

                                                                                                                                                   2
                                                                                                                                           E5ER

DeviceNet-compatible Controllers

Size      Control                       Control mode                   Outputs (control/      Optional functions                    Model

                type                                                   transfer)              Auxiliary     Event   DeviceNet

                                                                                              outputs       inputs  communi-

                                                                                              (SUB)                 cations

48 × 96   Basic control  Single-loop standard control                  2 points:              2 (See        2       Yes        E5ER-QTB-DRT

mm        (1 loop)       Single-loop heating and cooling control       Pulse voltage          note 2.)

                                                                       Pulse voltage/current

                                                                       2 points: Current and                                   E5ER-CTB-DRT

                                                                       Current

          2-loop con-    2-loop standard control                       2 points:              2 (See        None    Yes        E5ER-QTW-DRT

          trol           Single-loop heating and cooling control       Pulse voltage          note 2.)

                         Single-loop cascade control                   Pulse voltage/current

                         Single-loop standard control with remote      2 points: Current and                                   E5ER-CTW-DRT

                         SP                                            Current

                         Single-loop proportional control

          Position-pro-  Single-loop position-proportional control     Relay output           2 (See        None    Yes        E5ER-PRTF-DRT

          portional      (See note 3.)                                 (1 open, 1 closed)     note 2.)

          control

          (1 loop)

Note: 1.  Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC.

    2.    The auxiliary outputs are transistor outputs.

    3.    Can be switched between close control and floating control.

Inspection Results                                                              ■ Accessories (Order Separately)

The Inspection Report can be ordered at the same time as the Digital

Controller using the following model number.                                    Terminal Cover (Sold Separately)

Inspection Report (Sold Separately)                                                           Descriptions                          Model

          Descriptions                            Model                         Terminal Cover for E5ER                  E53-COV15

Inspection Report for E5ER              E5ER-K                                  Rubber Packing

                                                                                              Model

                                                                                Y92S-P5

                                                                                Note: The Rubber Packing is provided with the Digital Controller.

                                                                                                                                                   3
                                                                                                                                                                       E5ER

Specifications

■ Ratings

                           Supply voltage                          100 to 240 VAC, 50/60 Hz                                             24 VAC, 50/60 Hz; 24 VDC

Item                        (See note 1.)

Operating voltage range                         85% to 110% of rated supply voltage

Power consumption                               17 VA max. (with maximum load)                                   11 VA/7 W max. (with maximum load)

Sensor input (See note 2.)                      Thermocouple: K, J, T, E, L, U, N, R, S, B, W

                                                Platinum resistance thermometer: Pt100

                                                Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)

                                                Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)

                                                (Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input)

Control output     Voltage (pulse) output       12 VDC, 40 mA max. with short-circuit protection circuit

                   Current output               0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output)

                                                (Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)

                   Relay output                 Position-proportional control type (open, closed)

                                                N.O., 250 VAC, 1 A (including inrush current)

Auxiliary output                                Relay Output

                                                N.O., 250 VAC, 1 A (resistive load)

                                                Transistor Output

                                                Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5 V max.; Leakage                  current:  0.4    mA

                                                max.

Potentiometer input                             100 Ω to 2.5 kΩ

Event input        Contact                      Input ON: 1 kΩ max.; OFF: 100 kΩ min.

                   No-contact                   Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max.

                                                Short-circuit: Approx. 4 mA

Remote SP input                                 Refer to the information on sensor input.

Transfer output                                 Refer to the information on control output.

Control method                                  2-PID or ON/OFF control

Setting method                                  Digital setting using front panel keys or setting using serial communications

Indication method                               7-segment digital display and single-lighting indicator

                                                Character Height

                                                PV: 9.5 mm; SV: 7.2 mm; MV: 7.2 mm

Other functions                                 Depends on model.

Ambient operating temperature                   −10 to 55°C (with no icing or condensation)

                                                For 3 years of assured use: −10 to 50°C (with no icing or condensation)

Ambient operating humidity                      25% to 85%

Storage temperature                             −25 to 65°C (with no icing or condensation)

Note   1:  The supply voltage (i.e., 100 to 240 VAC or 24 VAC/VDC) depends on the model. Be sure to specify the required type when ordering.

       2: The Controller is equipped with multiple sensor input. Temperature input or analog input can be selected with the input type setting switch. There is basic

           insulation between power supply and input terminals, power supply and output terminals, and input and output terminals.

       3: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All E5@R Models.)

■ Input Ranges

Platinum           Resistance Thermometer,                                       Thermocouple, Current, or Voltage Input

Input type           Platinum                                                    Thermocouple                                                      Current             Voltage

                   Resistance

                   Thermometer

Name                    Pt100                K                 J         T       E           L  U         N      R       S       B       W            [mA]             [V]

                                                                                                                                         W/Re
                                                                                                                                          5-26 

            2300                                                                                                                         2300.0

            1800                                                                                                 1700.0  1700.0  1800.0

            1300                     1300.0                                                              1300.0

              900  850.0                               850.0                            850.0

Temper-       800

ature         700                               500.0                            600.0                                                             20 to  20 to  5 to  5 to         10 to

Range         600                                                 400.0  400.0                  400.0                                              4        0     1         0       0

(°C)          400           150.00

              200

              100                                                                                                                100.0

              0                                                                  0.0                             0.0     0.0             0.0

            −100                                −20.0  −100.0     −20.0                 −100.0

            −200   −200.0   −150.00  −200.0                              −200.0                 −200.0   −200.0

Setting              0         1     2          3      4          5      6       7           8  9        10      11      12      13      14        15       16   17    18           19

Minimum                                                                                                                                            (Depends on scaling and

setting unit       0.1°C    0.01°C                                                      0.1°C                                                      number of decimal places.)

(SP and alarm)

Input type                                                                              TC.PT                                                                               TC.PT

setting switch                                                           Set to TC.PT.  IN1                                                            Set to ANALOG.       IN1

                                                                                        TYPE                                                                                TYPE

                                                                                        ANALOG                                                                              ANALOG

                                                                                                The shaded       area    indicates the   setting   status at the time of purchase.

                                                                                                                                                                                           4
                                                                                                                                                                 E5ER

■ Characteristics

Indication accuracy       Thermocouple input with cold junction compensation: (±0.1% of PV or ±1°C, whichever is greater) ±1 digit max. (See note 1.)

                          Thermocouple input without cold junction compensation: (±0.1% FS or ±1°C, whichever is smaller) ±1 digit (See note 2.)

                          Analog input: ±0.1% FS ±1 digit max.

                          Platinum resistance thermometer input: (±0.1% of PV or ±0.5°C, whichever is greater) ±1 digit max.

                          Position-proportional potentiometer input: ±5% FS ±1 digit max.

Control mode              Standard control (heating or cooling control), heating/cooling control, standard control with remote SP (2-input models only), heating/cool-

                          ing control with remote SP (2-input models only), cascade standard control (2-input models only), cascade heating/cooling control (2-input

                          models only), proportional control (2-input models only), position-proportional control (control-valve control models only)

Influence of temperature  Thermocouple input (R, S, B, W): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                          Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max.

                          ∗K-type thermocouple at −100°C max.: ±10°C max.

Influence of temperature  Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

                          Analog input: (±1%FS) ±1 digit max.

Control period            0.2 to 99.0 s (in units of 0.1 s) for time-proportioning control output

Proportional band (P)     0.00% to 999.99% FS (in units of 0.01% FS)

Integral time (I)         0.0 to 3,999.9 s (in units of 0.1 s)

Derivative time (D)       0.0 to 3,999.9 s (in units of 0.1 s)

Hysteresis                0.01% to 99.99% FS (in units of 0.01% FS)

Manual reset value        0.0% to 100.0% (in units of 0.1% FS)

Alarm setting range       −19,999 to 99,999 EU (See note 3.) (The decimal point position depends on the input type and         the    decimal  point  position   setting.)

Input sampling period     50 ms

Insulation resistance     20 MΩ min. (at 500 VDC)

Dielectric strength       2,000 VAC, 50/60 Hz for 1 min (between charged terminals of different polarities)

Vibration resistance      10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

Shock resistance          100 m/s2, 3 times each in X, Y, and Z directions

Inrush current            100 to 240-VAC models: 50 A max.

                          24 VAC/VDC models: 30 A max.

Weight                    Controller only: Approx. 330 g; Mounting bracket: Approx. 60 g; Terminal cover: Approx. 16 g

Degree of protection      Front panel: NEMA4X for indoor use (equivalent to IP66); Rear case: IP20; Terminals: IP00

Memory protection         Non-volatile memory (number of writes: 100,000)

Applicable standards      UL61010C-1, CSA C22.2 No. 1010-1

                          EN61010-1 (IEC61010-1): Pollution degree 2/overvoltage category 2

EMC                       EMI: EN61326

                          Radiated Interference Electromagnetic Field Strength: EN55011 Group 1 Class A

                          Noise Terminal Voltage: EN55011 Group 1 Class A

                          EMS: EN61326

                          ESD Immunity: EN61000-4-2:                                       4 kV contact discharge (level 2)

                                                                                           8 kV air discharge (level 3)

                          Electromagnetic Immunity: EN61000-4-3:                           10 V/m (amplitude-modulated, 80 MHz to 1 GHz, 1.4 GHz to 2 GHz)         (level   3)

                          Burst Noise Immunity: EN61000-4-4:                               2 kV power line (level 3)

                                                                                           2 kV output line (relay output) (level 4)

                                                                                           1 kV measurement line, I/O signal line (level 4)

                                                                                           1 kV communications line (level 3)

                          Conducted Disturbance Immunity: EN61000-4-6:                     3 V (0.15 to 80 MHz) (level 3)

                          Surge Immunity: EN61000-4-5:                                     1 kV line to line (power line, output line (relay output)) (level 2)

                                                                                           2 kV line to ground (power line, output line (relay output)) (level 3)

                          Power Frequency Magnetic Field Immunity: EN61000-4-8:            30 A/m (50 Hz) continuous field

                          Voltage Dip/Interrupting Immunity: EN61000-4-11:                 0.5 cycle, 100% (rated voltage)

Note: 1.  K-, T-, or N-type thermocouple at −100°C max.: ±2°C ±1 digit max.

          U- or L-type thermocouple: ±2°C ±1 digit max.

          B-type thermocouple at 400°C max.: No accuracy specification.

          R- or S-type thermocouple at 200°C max.: ±3°C ±1 digit max.

          W-type thermocouple: (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.

     2.   U- or L-type thermocouple: ±1°C ±1 digit

          R- or S-type thermocouple at 200°C max.: ±1.5°C ±1 digit

     3.   “EU” (Engineering Unit) represents the unit after scaling. If a temperature sensor is used it is either °C or °F.

     4.   Conditions: Ambient temperature from −10 to 23 to 55°C and voltage of −15% to 10% of rated voltage.

                                                                                                                                                                                5
                                                                                                                                        E5ER

■ Communications Specifications

Transmission path connection                  Multiple points

Communications method                         RS-485 (two-wire, half duplex)

Synchronization method                        Start-stop synchronization

Baud rate                                     9,600, 19,200, or 384,000 bps

Transmission code                             ASCII

Data bit length                               7 or 8 bits

Stop bit length                               1 or 2 bits

Error detection                               Vertical parity (none, even, odd)

                                              Block check character (BCC): CompoWay/F

                                              CRC-16: Modbus

Flow control                                  None

Interface                                     RS-485

Retry function                                None

Communications buffer                         217 bytes

Communications response send wait       time  0 to 99 ms, Default: 20 ms

DeviceNet

                   Item                                                               Specifications

Communications protocol                       Conforms to DeviceNet

Communications         Remote I/O             • Master-slave connections (polling, bit-strobe, COS, or cyclic)

functions              communications         • Conform to DeviceNet specifications.

                       I/O allocations        • Can allocate any I/O data from the Configurator.

                                              • Can allocate any data, such as parameters specific to the Devicenet, and the Digital Controller

                                              variable area.

                                              • Up to 2 blocks for the IN Area, up to a total of 100 words.

                                              • One block for the OUT Area, up to 100 words (first word is always allocated to Output Enable

                                              Bits).

                       Message                • Explicit message communications

                       communications         • CompoWay/F communications commands can be sent (commands are sent in explicit mes-

                                              sage format).

Connection format                             Combination of multidrop and T-branch connections (for trunk and drop lines)

Baud rate                                     DeviceNet: 500, 250, or 125 kbps, or automatic detection of master baud rate

Communications media                          Special 5-wire cable (2 signal lines, 2 power lines, and 1 shield line)

Communications distance                       Baud rate        Network length                     Drop line length          Total drop line length

                                              500 kbps         100 m max. (100 m max.)            6 m max.                  39 m max.

                                              250 kbps         250 m max. (100 m max.)            6 m max.                  78 m max.

                                              125 kbps         500 m max. (100 m max.)            6 m max.                  156 m max.

                                              The values in parentheses apply when Thin Cables are used.

Supply voltage                                DeviceNet power supply: 24 VDC

Allowable voltage range                       DeviceNet power supply: 11 to 25 VDC

Current consumption                           50 mA max. (24 VDC)

Maximum number of nodes that can be           64 (includes Configurator when used)

connected

Maximum number of slaves that can be          63

connected

Error control                                 CRC error detection

Power supply                                  Power supplied from DeviceNet communications connector.

                                                                                                                                                    6
                                                                                                                                                                                                E5ER

Wiring Terminals

■ E5ER Standard Controller                                                                       Connections

E5ER-Q4B                                                                                         E5ER-C4B

E5ER-AB-500                             A           B        E53-ARR4                            E5ER-AB-500                         A             B        E53-ARR4

24 VAC/DC 100-240 VAC                1                                   Auxiliary outputs       24 VAC/DC 100-240 VAC            1                                     Auxiliary outputs

-     +                                                         B        (Relay outputs)         -     +                                                          B     (Relay outputs)

+     -                              2                          1                 COM            +     -                          2                               1              COM

                                     3                          2                 SUB1                                            3                               2              SUB1

                                     4                          3                 SUB2                                            4                               3              SUB2

Input power supply                   5                          4                COM             Input power supply               5                               4             COM

depends on the model.                                                                            depends on the model.

100 to 240 VAC                       6                          5                 SUB3           100 to 240 VAC                   6                               5              SUB3

or 24 VAC/DC                                                                                     or 24 VAC/DC

(no polarity)                        1                          6                 SUB4           (no polarity)                    1                               6              SUB4

                                     2                                                                                            2

                                     3                                                                                            3

                                     4                                                                                            4

                                     5                                                                                            5

                                     6                                                                                            6

                                        C  D        E                                                                                C    D        E

E53-ARQC                                      E5ER-AB-500                                        E53-ARCC                                    E5ER-AB-500

                           1                                 Event inputs                 1                                    1                            Event inputs                 1

                                                                EV1                                                                                               EV1

OUT2                       2                                    EV2                       2      OUT2                          2                                  EV2                    2

Voltage output          +  3                                                                     Current output          +     3

12 V  40 mA                                                     COM                       3      4-20 mA DC, 500 Ω max.                                           COM                    3

                        -  4                  +                                                  0-20 mA DC, 500 Ω max.  -     4             +

OUT1                                                                                      4      (Switching by output                                                                    4

Voltage output          +  5                  -        -                    -             5      type setting)           +     5             -        -                     -            5

12 V  40 mA or          -                                                                        OUT1                    -

Current output             6                           +                    +             6      Current output                6                      +                      +           6

4-20 mA DC, 500 Ω max.     C                     I        V     PT            TC          E      4-20 mA DC, 500 Ω max.        C                I        V           PT      TC          E

0-20 mA DC, 500 Ω max.                     (Current) (Voltage)           (Thermocouple)          0-20 mA DC, 500 Ω max.                      (Current) (Voltage)         (Thermocouple)

(Switch using output type  setting.)                   (Resistance thermometer)                  (Switch using output type     setting.)              (Resistance thermometer)

E5ER-Q43B-FLK                                                                                    E5ER-C43B-FLK

E5ER-AB-500                                A              B        E53-ARR4                      E5ER-AB-500                              A              B           E53-ARR4

                100-240 VAC                                                   Auxiliary outputs                  100-240 VAC                                                 Auxiliary outputs

                                        1                                B    (Relay outputs)                                        1                                  B    (Relay outputs)

                                        2                                1                COM                                        2                                   1               COM

                                        3                                2                SUB1                                       3                                   2               SUB1

                                        4                                3                SUB2                                       4                                   3               SUB2

                                        5                                4                COM                                        5                                   4               COM

E53-ARQC3       +                                                        5                SUB3                                                                           5               SUB3

RS-485   B(+)           1               6                                                                                            6

         A(-)   -       2               1                                6                SUB4                                       1                                   6               SUB4

OUT2

Voltage output  +       3               2                                                                                            2

12 V  40 mA     -

OUT1                    4               3                                                                                            3

Voltage output  +       5               4                                                                                            4

12 V  40 mA or

Current output  -       6               5                                                                                            5

4-20 mA DC, 500 Ω max.  C

0-20 mA DC, 500 Ω max.                  6                                                                                            6

(Switch using output type setting.)        C     D        E                                                                               C     D        E

                                                    E5ER-AB-500                                     E53-ARCC3                                      E5ER-AB-500

                                                                   Event inputs                                          B(+)  +  1                                  Event inputs            1

                                                                         EV1                  1               RS-485                                                    EV1

                                                                                                                         A(-)  -  2

                                                                         EV2                  2     OUT2                                                                EV2                  2

                                                                                                    Current output             +  3

                                                                         COM                  3        4-20 mA DC, 500 Ω max.                                           COM                  3

                                                    +                                                  0-20 mA DC, 500 Ω max.  -  4                +

                                                                                              4     (Switch using output                                                                     4

                                                    -        -                    -           5     type setting.)             +  5                -        -                    -           5

                                                                                                    OUT1                       -  6

                                                             +                    +           6     Current output                                          +                    +           6

                                                       I        V        PT       TC          E        4-20 mA DC, 500 Ω max.     C                   I           V      PT      TC          E

                                                    (Current) (Voltage)       (Thermocouple)           0-20 mA DC, 500 Ω max.                      (Current) (Voltage)       (Thermocouple)

                                                                (Resistance thermometer)            (Switch using output type setting.)                     (Resistance thermocouple)

                                                                                                                                                                                                      7
                                                                                                                                                                                                  E5ER

E5ER-QT3DB-FLK                                                                                      E5ER-CT3DB-FLK

E5ER-AB-500                                      A        B           E53-ARB4                      E5ER-AB-500                                   A        B     E53-ARB4

                  100-240 VAC                                                             B                               100-240 VAC                                                   B

                                           1                       Event inputs                                                                1                 Event inputs

                                                                                          1                                                                                             1

                                           2                       EV3                    2                                                    2                 EV3                    2

                                           3                       EV4                    3                                                    3                 EV4                    3

                                           4                       EV5                    4                                                    4                 EV5                    4

E53-ARQC3            +                     5                       EV6                    5         E53-ARCC3                                  5                 EV6                    5

            B(+)           1               6                                                                        B(+)    +     1            6

RS-485               -                                             COM                    6         RS-485                                                       COM                    6

            A(-)           2               1                                                                        A(-)    -     2            1

OUT2                 +                                                                              OUT2                    +

Voltage output             3               2                                                        Current output                3            2

12 V 40 mA           -                                                                              4-20 mA DC, 500 Ω max.  -

OUT1                       4               3                                                        0-20 mA DC, 500 Ω max.        4            3

Voltage output       +     5               4                                                        (Switch using output    +     5            4

12 V 40 mA or                                                                                       type setting.)

Current output       -     6               5                                                        OUT1                    -     6            5

4-20 mA DC, 500 Ω max.  C                                                                           Current output             C

0-20 mA DC, 500 Ω max.                     6                                                        4-20 mA DC, 500 Ω max.                     6

(Switch using output type setting.)              C  D     E                                         0-20 mA DC, 500 Ω max.                        C  D     E

                                                                                                    (Switch using output type setting.)

E53-ART2                                               E5ER-AB-500                                  E53-ART2                                            E5ER-AB-500

Auxiliary outputs                                                  Event inputs                  1  Auxiliary outputs                                            Event inputs                  1

                              1                                          EV1                                                             1                                EV1

(Transistor outputs)                                                     EV2                     2  (Transistor outputs)                                                  EV2                  2

                              2                                                                                                          2

                        +     3                                          COM                     3                             +         3                                COM                  3

            SUB1                                    +                                            4                  SUB1                             +                                         4

                        -     4                                                                                                -         4

                                                    -           -                -               5                                                   -        -                -               5

                        +     5                                                                                                +         5

            SUB2        -     6                                 +                +               6                  SUB2       -         6                    +                +               6

                              D         D              I        V           PT   TC              E                                       D  D           I     V           PT   TC              E

                                                    (Current) (Voltage)          (Thermocouple)                                                      (Current) (Voltage)       (Thermocouple)

                                                                (Resistance thermometer)                                                                      (Resistance thermometer)

E5ER-QC43B-FLK

E5ER-AB-500                                      A           B           E53-ARR4

      24 VAC/DC         100-240 VAC                                              Auxiliary outputs

      -           +                           1                             B    (Relay outputs)

      +         -                             2                             1             COM

Input power supply depends                                                  2             SUB1

on the model.                                 3

100 to 240 VAC                                4                             3             SUB2

or 24 VAC/DC (no polarity)

                                              5                             4             COM

E53-ARQC3            +                                                      5             SUB3

RS-485      B(+)           1                  6

            A(-)     -     2                  1                             6             SUB4

OUT2                 +                        2

Voltage output             3

12 V 40 mA           -     4                  3

OUT1

Voltage output       +     5                  4

12 V 40 mA or        -

Current output             6                  5

4-20 mA DC, 500 Ω max.     C

0-20 mA DC, 500 Ω max.                        6

(Switch using output type setting.)              C  D        E

      E53-ARCC                                         E5ER-AB-500

                                           1                          Event inputs               1

                                                                            EV1

OUT4                                       2                                EV2                  2

Current output                       +     3

      4-20 mA DC, 500 Ω max.                                                COM                  3

      0-20 mA DC, 500 Ω max.         -     4           +

(Switch using output                                                                             4

type setting.)                       +     5           -        -                -               5

OUT3                                 -     6

Current output                                                  +                +               6

      4-20 mA DC, 500 Ω max.               D              I        V        PT      TC           E

      0-20 mA DC, 500 Ω max.                           (Current) (Voltage)       (Thermocouple)

(Switch using output type               setting.)               (Resistance thermometer)

                                                                                                                                                                                                        8
                                                                                                                                                                                                                E5ER

E5ER-QT3DW-FLK (2-loop Control)                                                                       E5ER-CT3DW-FLK (2-loop Control)

E5ER-AW-500                                   A           B           E53-ARB4                        E5ER-AW-500                                      A           B              E53-ARB4

      24 VAC/DC 100-240 VAC                                                           B                         24 VAC/DC 100-240 VAC                                                                 B

      -         +                          1                       Event inputs                                 -          +                        1                       Event inputs

                                                                                      1                                                                                                               1

      +         -                          2                       EV3                2                         +          -                        2                       EV3                       2

Input power supply depends                                                                            Input power supply depends

on the model.                              3                       EV4                3               on the model.                                 3                       EV4                       3

100 to 240 VAC                             4                                                          100 to 240 VAC                                4

or 24 VAC/DC (no polarity)                                         EV5                4               or 24 VAC/DC (no polarity)                                            EV5                       4

E53-ARQC3                                  5                       EV6                5               E53-ARCC3                                     5                       EV6                       5

            B(+)   +       1               6                                                                               B(+)     +     1         6

RS-485                                                             COM                6                     RS-485                  -                                       COM                       6

            A(-)   -       2               1                                                                               A(-)           2         1

OUT2               +                                                                                  OUT2                          +

Voltage output             3            2                                                             Current output                      3         2

12 V 40 mA         -                                                                                  4-20  mA  DC,   500  Ω  max.  -

OUT1                       4               3                                                          0-20  mA  DC,   500  Ω  max.        4         3

Voltage output     +       5                                                                          (Switch using output          +     5

12 V 40 mA or                              4                                                          type setting.)                                4

Current output     -       6               5                                                          OUT1                          -     6         5

4-20 mA DC, 500 Ω max.                                                                                Current output

0-20 mA DC, 500 Ω max.   C                 6                                                          4-20 mA DC, 500 Ω max.           C            6

(Switch using output type setting.)                                                                   0-20 mA DC, 500 Ω max.

                                              C     D     E                                           (Switch using output type setting.)              C  D        E

E53-ART2                                         E5ER-AW-500                                                    E53-ART2                                  E5ER-AW-500
                                                          +                                                                                                        +
                                                                                                   1                                                                                                         1
Auxiliary outputs             1                                                                               Auxiliary outputs              1

(Transistor outputs)                             Input 2  -        -               -               2          (Transistor outputs)                        Input 2  -        -                      -         2

                              2                                                    +               3                                         2                                                     +         3

                        +     3                           +  I     +V          PT  TC                                                  +     3                     +  I     +V           PT        TC

            SUB1        -                                                                          4                       SUB1        -                                                                     4

                              4                  Input 1  -        -               -               5                                         4            Input 1  -        -                      -         5

                        +     5                                                                                                        +     5

            SUB2        -     6                                    +               +               6                       SUB2        -     6                              +                      +         6

                                     D                       I        V        PT  TC           E                                               D                     I           V      PT        TC       E
                                                          (Current) (Voltage)                                                                                      (Current) (Voltage)
                              D                                                    (Thermocouple)                                            D                                               (Thermocouple)

                                                                   (Resistance thermometer)                                                                                 (Resistance thermometer)

E5ER-PRTDF                                                                                            E5ER-PRQ43F-FLK

E5ER-PAF-500                                                       E53-ARB4                           E5ER-PAF-500                                        A              B           E53-ARR4

      24 VAC/DC         100-240 VAC           A        B                           B                            24 VAC/DC           100-240 VAC        1                                   Auxiliary outputs

      -         +                                                  Event inputs                                   -        +                                                            B  (Relay outputs)

                                        1                                          1                                                                   2                                1                COM

      +         -                       2                          EV3             2                              +        -

Input power supply depends                                                                            Input power supply depends                       3                                2                SUB1

on the model.                           3                          EV4             3                  on the model.

100 to 240 VAC                                                                                        100 to 240 VAC or 24 VAC/DC                      4                                3                SUB2

or 24 VAC/DC (no polarity)              4                          EV5             4                  (no polarity)

                                                                                                                                                       5                                4             COM

                                        5                          EV6             5                  E53-ARRR3                                        6

E53-ARRR                                                                                                    B(+)      +       1                                                         5                SUB3

                                        6                          COM             6                                                                   1

      1                                                                                               RS-485          -                                                                 6                SUB4
                                                                                                            A(-)
                                        1                                                                                     2  Relay output
                                                                                                                                                       2
      2     Relay output                                                                                                         250 VAC        1A
                                                                                                                              3
            250 VAC      1A             2                                                                       OUT2                   Closed          3

OUT2  3            Closed               3                                                                                     4                        4

      4                                 4                                                                                     5                        5

      5                                                                                                         OUT1                   Open

OUT1               Open                 5                                                                                     6                        6

      6                                 6                                                                                  C                              C  D        E

      C                                       C  D     E

                                                                                                                E53-ARQC                                     E5ER-PAF-500

                E53-ART2                                     E5ER-PAF-500                                                                           1        Potentiometer                    O          1

            Auxiliary outputs                                Potentiometer            O            1                                                                                          W

            (Transistor outputs)           1                                          W                       OUT4                                  2                                                    2

                                                                                                   2          Voltage output                    +   3                                         C          3

                                           2                                          C            3            12 V       40 mA                -            +

                                     +     3              +                                                   OUT3                                  4                                                    4

                        SUB1         -                                                             4          Voltage output                    +   5        -        -                    -             5

                                           4              -        -               -               5            12 V 40 mA or                   -

                                     +     5                                                                  Current output                        6                 +                    +             6

                        SUB2                                       +               +               6            4-20 mA DC, 500 Ω max.              D           I        V           PT      TC          E

                                     -     6                                                       E            0-20 mA DC, 500 Ω max.                       (Current) (Voltage)         (Thermocouple)

                                                 D              I     V        PT  TC                         (Switch using output type setting.)                        (Resistance thermometer)
                                                          (Current) (Voltage)
                                           D                                       (Thermocouple)

                                                                      (Resistance thermometer)

                                                                                                                                                                                                                      9
                                                                                                                                                                                                        E5ER

■ E5ER DeviceNet-compatible                                                                             Controller Connections

E5ER-QTB-DRT                                                                                            E5ER-CTB-DRT

E5ER-AB-500                                A           B        E53-ARDRT                               E5ER-AW-500                                A        B        E53-ARDRT

      24 VAC/DC 100-240 VAC                                           DeviceNet Connector                     24 VAC/DC 100-240 VAC                                  DeviceNet Connector

      -         +                       1                                                                     -         +                       1

                                                                      Red      (V+)                                                                                     Red      (V+)

      +         -                       2                             White (CAN H)                           +         -                       2                       White (CAN H)

Input power supply                                                    −        (Shield)                 Input power supply depends                                      −        (Shield)

depends on the model.                   3                             Blue     (CAN L)                  on the model.                           3                       Blue     (CAN L)

100 to 240 VAC                                                        Black (V−)                        100 to 240 VAC                          4                       Black (V−)

or 24 VAC/DC (no polarity)              4                                                               or 24 VAC/DC (no polarity)

E53-ARQC                                5                                                               E53-ARCC                                5

                           1            6                                                                                             1         6

                           2            1                                                               OUT2                          2         1

OUT2               +                    2                                                               Current output          +     3         2

Voltage output             3                                                                            4-20 mA DC, 500 Ω max.

12 V 40 mA         -       4            3                                                               0-20 mA DC, 500 Ω max.  -     4         3

OUT1                                                                                                    (Switch using output

Voltage output     +       5            4                                                               type setting.)          +     5         4

12 V 40 mA or      -                                                                                    OUT1                    -

Current output             6            5                                                               Current output                6         5

4-20 mA DC, 500 Ω max.  C                                                                               4-20 mA DC, 500 Ω max.     C

0-20 mA DC, 500 Ω max.                  6                                                               0-20 mA DC, 500 Ω max.                  6

(Switch using output type setting.)        C  D        E                                                (Switch using output type setting.)        C  D     E

E53-ART2                                         E5ER-AB-500                                                  E53-ART2                             E5ER-AW-500
                                                                                                                                                            +
                                                             Event inputs                                                                                                                            1
Auxiliary outputs                                                                           1                 Auxiliary outputs
                              1                                       EV1                                                                1
                                                                                                                                                                  -
(Transistor outputs)                                                                                          (Transistor outputs)                 Input 2  -                        -               2

                              2                                       EV2                   2                                            2

                        +                                             COM                   3                                      +                           I  +V             PT  +               3
                                                                                                                                                                                       TC
                              3                  +                                                                                       3                  +
                                                                                                                                                                                                     4
            SUB1        -                                                                   4                           SUB1       -

                              4                           -                    -                                                         4         Input 1  -     -                  -               5

                        +     5                  -                                          5                                      +     5

            SUB2        -                                 +                    +            6                           SUB2       -                              +                  +               6

                              6      D              I     V           PT       TC           E                                            6   D                 I     V           PT    TC   E

                              D                  (Current) (Voltage)        (Thermocouple)                                               D                  (Current) (Voltage)      (Thermocouple)

                                                          (Resistance thermometer)                                                                                (Resistance thermometer)

E5ER-QTW-DRT (2-loop Control)                                                                           E5ER-CTW-DRT (2-loop Control)

E5ER-AW-500                                   A           B              E53-ARDRT                      E5ER-AW-500                                A        B        E53-ARDRT

      24 VAC/DC 100-240 VAC                                              DeviceNet Connector                  24 VAC/DC 100-240 VAC                                  DeviceNet Connector

      -         +                          1                                                                  -         +                       1

                                                                           Red    (V+)                                                                                  Red      (V+)

      +         -                          2                               White (CAN H)                      +         -                       2                       White (CAN H)

Input power supply depends                                                 −      (Shield)              Input power supply depends                                      −        (Shield)

on the model.                              3                               Blue   (CAN L)               on the model.                           3                       Blue     (CAN L)

100 to 240 VAC                             4                               Black (V−)                   100 to 240 VAC                                                  Black (V−)

or 24 VAC/DC (no polarity)                                                                              or 24 VAC/DC (no polarity)              4

E53-ARQC                                   5                                                            E53-ARCC                                5

                                 1         6                                                                                          1         6

                                 2         1                                                            OUT2                          2         1

OUT2                    +        3         2                                                            Current output          +

Voltage output                                                                                          4-20 mA DC, 500 Ω max.        3         2

12 V 40 mA              -        4         3                                                            0-20 mA DC, 500 Ω max.  -     4         3

OUT1                                                                                                    (Switch using output

Voltage output          +        5         4                                                            type setting.)          +     5         4

12 V 40 mA or           -                                                                               OUT1                    -

Current output                   6         5                                                            Current output                6         5

4-20 mA DC, 500 Ω max.        C                                                                         4-20 mA DC, 500 Ω max.     C

0-20 mA DC, 500 Ω max.                     6                                                            0-20 mA DC, 500 Ω max.                  6

(Switch using output type setting.)           C     D     E                                             (Switch using output type setting.)        C  D     E

      E53-ART2                                E5ER-AW-500                                                     E53-ART2                             E5ER-AW-500
                                                          +                                                                                                 +
                                                                                                     1                                                                                               1
      Auxiliary outputs              1                                                                        Auxiliary outputs
                                                                                                                                         1
      (Transistor outputs)                    Input 2     -           -                     -        2        (Transistor outputs)                 Input 2  -     -                  -               2

                                     2                                                      +        3                                   2                                           +               3

                              +      3                    +  I        +V       PT           TC                                     +     3                  +  I  +V             PT    TC

                SUB1          -                                                                      4                  SUB1       -                                                                 4

                                     4        Input 1     -           -                     -        5                                   4         Input 1  -     -                  -               5

                              +      5                                                                                             +     5

                SUB2          -      6                                +                     +        6                  SUB2       -                              +                  +               6

                                        D                    I           V      PT          TC  E                                        6   D                 I     V           PT    TC   E

                                     D                    (Current) (Voltage)        (Thermocouple)                                      D                  (Current) (Voltage)      (Thermocouple)

                                                                      (Resistance thermometer)                                                                    (Resistance thermometer)

                                                                                                                                                                                                              10
                                                                                             E5ER

E5ER-PRTF-DRT

E5ER-PAF-500                            A     B        E53-ARDRT

      24 VAC/DC   100-240 VAC                          DeviceNet Connector

      -        +                  1

                                                       Red            (V+)

      +        -                  2                    White (CAN H)

Input power supply depends                             −              (Shield)

on the model.                     3                    Blue           (CAN L)

100 to 240 VAC                    4                    Black (V−)

or 24 VAC/DC (no polarity)

                                  5

E53-ARRR                          6

      1                           1

      2  Relay output             2

      3  250 VAC  1A

OUT2              Closed          3

      4                           4

OUT1  5           Open            5

      6                           6

      C                                 C  D  E

          E53-ART2                               E5ER-PAF-500

          Auxiliary outputs                      Potentiometer                  O         1

          (Transistor outputs)       1                                          W         2

                                     2                                          C         3

                               +     3           +

                  SUB1         -                                                          4

                                     4           -     -                    -             5

                               +     5

                  SUB2         -                       +                    +             6

                                     6     D        I     V           PT    TC            E

                                     D           (Current) (Voltage)      (Thermocouple)

                                                       (Resistance thermometer)

                                                                                             11
                                                                                                                                                                      E5ER

Nomenclature

E5ER

      Operation

      Indicators

                                                               No. 1 Display                                                   MS/NS Indicators

                                                                                                                               Top: MS

                                                               No. 2 Display                                                   Bottom: NS

                                                               No. 3 Display

                                                                                                                               DeviceNet communications connector

                                                                                                                               Used to connect the DeviceNet

                                                                                                                               communications cables.

      Mode Key                                                 Down Key                                                        The DeviceNet communications power is

                                                                                                                               also supplied through this connector.

      Level Key                                                Up Key                                                          The connector included with the

                                                                                                                               DeviceNet-compatible

                                                                                                                               Controllers is the FKC 2.5/5-STF-5.08 AU  M

                                                                                                                               (PHOENIX CONTACT).

                  Function Key 1/      Function Key 2/

                  Auto/Manual Key      Channel Key

Dimensions

Note: All units are in millimeters unless otherwise            indicated.

E5ER                                                                             110

                                                               11.5              95 (99)*

                                             48                3              2                                      Terminal  cover  (E53-COV15; sold separately)

                                                                                                               1

                                                                                                               2

                                                                                                               3

                                                                                                               4

                                                                                                               5

                                                                                                               6

                  96                                                                                                 111

                                                                                                               1

                                                                                                               2

                                                                                                               3

                                                                                                               4

                                                                                                               5

                                                                                                               6

                                                                              Mounting Bracket (Accessory)                            Crimp terminal size: M3

                                                                                 * The value in parentheses are for

                                                                                 DeviceNet-compatible Controllers.

                                   Panel Cutouts

                                   45  +0.6

                                       0

                                             60 min.

                  120 min.

                                                            •  Recommended panel thickness is 1 to 8 mm.

                                                            •  Group mounting is not possible. (Maintain the

                                                               specified mounting space between Controllers.)

                                             92       +0.8

                                                      0     •  When two or more Controllers are mounted,

                                                               make sure that the surrounding temperature

                                                               does not exceed the allowable operating

                                                               temperature specified in the specifications.

                                                                                                                                                                            12
                                                                                                                            E5ER

■ Accessories (Order              Separately)

Terminal Cover

E53-COV15 (for E5ER)

                              48

                          95

                      28.5

                      10.1

Unit Label  Sheet

Y92S-L1

                                  11.8

                                              4.8

Rubber Packing

Y92S-P5 (for DIN48 × 96)

                      Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 3.)

                      The Rubber Packing can be used to achieve an IP66 degree of protection.

                      (Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating environment.

                      Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA4. The time

                      for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider

                      one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform

                      periodic replacement.)

                      The Rubber Packing does not need to be attached if a waterproof structure is not required.

            ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

            To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                              In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                               13
                                                      Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or

comments.

                                                      Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)

from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR

FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.                     ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.                                OMRON DISCLAIMS ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS

IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS

OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT

SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                      Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's

application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the

products.   This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,

machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given.             This is not intended to be an exhaustive list of all possible

uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

   safety equipment, and installations subject to separate industry or government regulations.

  Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                    Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.

However, some specifications of the products may be changed without any notice.     When in doubt, special model numbers may be assigned to fix or

establish key specifications for your application on your request.  Please consult with your OMRON representative at any time to confirm actual

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent               the

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON

Warranty and Limitations of Liability.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,

typographical, or proofreading errors, or omissions.

                                                                                                                                                                         2012.8

                                                      In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                                  (c)Copyright OMRON Corporation 2012 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

E5ER-C43B-FLK AC100-240V  E5ER-C4B AC100-240      E5ER-C4B AC/DC24  E5ER-CT3DB-FLK AC100-240V  E5ER-

CT3DW-FLK AC100-240     E5ER-CT3DW-FLK AC/DC24    E5ER-CTW-DRT AC100-240V  E5ER-PRQ43F-FLK AC100-

240   E5ER-PRQ43F-FLK AC/DC24  E5ER-PRTDF AC100-240  E5ER-PRTDF AC/DC24    E5ER-Q43B-FLK AC100-240V

E5ER-Q4B AC100-240      E5ER-Q4B AC/DC24  E5ER-QC43B-FLK AC100-240  E5ER-QC43B-FLK AC/DC24     E5ER-

QT3DB-FLK AC100-240V    E5ER-QT3DW-FLK AC100-240  E5ER-QT3DW-FLK AC/DC24   E5ER-QTB-DRT AC100-

240V  E5ER-QTW-DRT AC100-240V  E5ER-CTB-DRT AC100-240V  E5ER-PRTF-DRT AC24V