Basic-type Digital Temperature Controller

E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

                                                                                                                                                                              CSM_E5AN_E5EN_DS_E_3_2

New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with
Enhanced Functions and Performance.
Improved Indication Accuracy and
Preventive Maintenance Function.

Indication Accuracy                                                                      96 96 mm       48 96 mm
Thermocouple input: 0.3% of PV (previous models: 0.5%)                                      E5AN             E5EN
Pt input: 0.2% of PV (previous models: 0.5%)
Analog input: 0.2% FS (previous models: 0.5%)                                                Refer to Safety Precautions for E5@N/E5@N-H.

A PV/SV-status display function can be set to automatically                              Refer to Operation for E5@N/E5@N-H for operating
alternate between displaying the status of the Temperature                                procedures.
Controller (auto/manual, RUN/STOP, and alarms) and the PV or
SV.

Preventive maintenance for relays in the Temperature Controller
using a Control Output ON/OFF Counter.

Three-level display that simultaneously displays the PV, SV, and
MV.

One-touch operation with PF Key that can be assigned to auto/
manual, RUN/STOP, or other functions.

Main I/O Functions                                     E5AN                 E5EN           3-level Display *
                                                                                           Simultaneously displays set items,
                                    Event Inputs
                                     None                                                 such as the PV, SV, and MV.
                                     Two
                                                                                           * A 2-level display when shipped from the factory. A
        Sensor Inputs                                                                         3-level display is activated if parameters are
         Universal thermocouple/Pt inputs                                                    initialized. For details on the third display level, refer
                                                                                              to the User's Manual, Basic Type (Cat. No. H156).
         (Models with temperature inputs)
         Analog current/voltage inputs                                                    4-digit Display

         (Models with analog inputs)                                        Auxiliary Outputs                Auto/manual switching
                                                                            Three                         Temperature Controller
        Indication Accuracy
         Thermocouple input: 0.3% of PV              Control Output 2                                       status display
         Pt input: 0.2% of PV                         Voltage output                                     Simple program function
         Analog input: 0.2% FS                                                                            Control output ON/OFF
                                                         (for driving SSR)
        Sampling Period                                 Long-life relay                                      count alarm
         250 ms                                                                                             PV change rate alarm
                                                         output (hybrid)                                     Models also available with
                          PF Key
                          (Programmable function key)                                                         RS-485 or RS-232C
                                                                                                              communications

                                                       Control Output 1
                                                       Relay output
                                                       Voltage output (for driving SSR)
                                                       Current output

This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)

                                                                                 1
                                                                                                                         E5AN/E5EN

Lineup

E5AN/E5EN   Terminal block  Temperature input                                                         1 control output   3 auxiliary outputs
Basic Type                     Analog input                                                           2 control outputs  3 auxiliary outputs
                                                                                                      1 control output   3 auxiliary outputs
                                                                                                      2 control outputs  3 auxiliary outputs

Note: Models with one control output or two control outputs can be used for heating/cooling control.

Model Number Structure                                                Option Units

Model Number Legend                                                   E53-@

Controllers                                                                      1

E5AN/E5EN-@3@M@@-@-500-N                                              1. Function
                                                                          EN01: RS-232C communications
                            123 4 5 6 7 8 9                               EN03: RS-485 communications
                                                                          AKB: Event input
1. Control Output 1
    R: Relay output
    Q: Voltage output (for driving SSR)
    C: Current output

2. Auxiliary Outputs
    3: Three outputs

3. Heater Burnout/SSR Failure, Control Output 2, or External
    Power Supply for ES1B
    Blank: None
    Q: Control output 2 (voltage output for driving SSR)
    Y: Long-life relay output (hybrid)
    H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
    HH: Heater burnout/SSR failure/Heater overcurrent detection
          (CT2)
    P: Power supply for sensor

4. Option
    M: Option Unit can be mounted.

5. Input Type
    T: Universal thermocouple/platinum resistance thermometer input
    L: Analog current/voltage input

6. Power Supply Voltage
    Blank: 100 to 240 VAC
    D: 24 VAC/VDC

7. Case Color
    Blank: Black
    W: Silver

8. Terminal Cover
    -500: With terminal cover

9. Version
    N: Available only to models released after January 2008.

                                                                                                                                              2
                                                                                                               E5AN/E5EN

Ordering Information

E5AN
Controllers with Terminal Blocks

              Case    Power                       Auxiliary                             Functions
              color   supply                      outputs
Size                  voltage     Input type                 Control output 1   Heater  Power supply Control   Model

                                                                                burnout for Sensor output 2

                                                             Relay output                                      E5AN-R3MT-500-N

                                                             Voltage output                                    E5AN-Q3MT-500-N
                                                             (for driving SSR)

                                                             Current output                                    E5AN-C3MT-500-N

                                                             Relay output       1                              E5AN-R3HMT-500-N

                                                             Voltage output     1                              E5AN-Q3HMT-500-N
                                                             (for driving SSR)

                                                             Relay output       2                              E5AN-R3HHMT-500-N

                                                             Voltage output     2                              E5AN-Q3HHMT-500-N
                                                             (for driving SSR)

                               Thermocouple                                                           Voltage
                                                                                                      output
                               or                 3          Relay output                                      E5AN-R3QMT-500-N
                               Resistance                                                             Voltage  E5AN-Q3QMT-500-N
                                                                                                      output
                               thermometer                   Voltage output
                                                             (for driving SSR)

                                                             Current output                           Voltage  E5AN-C3QMT-500-N
                                                                                                      output
                                                             Relay output
                      100 to                                 Voltage output                                         E5AN-R3YMT-500-N
                      240 VAC                                (for driving SSR)                        Long-life
                                                             Current output
                                                                                                      relay E5AN-Q3YMT-500-N

                                                                                                      output
                                                                                                                    E5AN-C3YMT-500-N

              Black                                          Relay output               Sensor Power           E5AN-R3PMT-500-N
                                                                                        Sensor Power           E5AN-Q3PMT-500-N
                                                             Voltage output
                                                             (for driving SSR)

                                                             Relay output                                      E5AN-R3ML-500-N

                                                             Voltage output                                    E5AN-Q3ML-500-N
                                                             (for driving SSR)                                 E5AN-C3ML-500-N
                                                                                                               E5AN-R3HML-500-N
1/4 DIN                                                      Current output                                    E5AN-Q3HML-500-N
96 96 78
(W H D)                    Analog             3          Relay output       1
                               (current/voltage)
                                                             Voltage output
                                                             (for driving SSR)  1

                                                             Voltage output                           Long-life
                                                             (for driving SSR)                        relay E5AN-Q3YML-500-N
                                                                                                      output

                                                             Relay output                                      E5AN-R3MTD-500-N

                                                             Voltage output                                    E5AN-Q3MTD-500-N
                                                             (for driving SSR)

                               Thermocouple                  Current output                                    E5AN-C3MTD-500-N
                                                                                                               E5AN-R3HMTD-500-N
                      24 VAC/ or                  3          Relay output       1
                                                                                                               E5AN-Q3HMTD-500-N
                      VDC      Resistance                    Voltage output
                                                             (for driving SSR)
                               thermometer                                      1

                                                             Relay output       2                              E5AN-R3HHMTD-500-N

                                                             Voltage output     2                              E5AN-Q3HHMTD-500-N
                                                             (for driving SSR)

                                                             Relay output                                      E5AN-R3MT-W-500-N

                                                             Voltage output                                    E5AN-Q3MT-W-500-N
                                                             (for driving SSR)                                 E5AN-C3MT-W-500-N
                                                                                                               E5AN-R3HMT-W-500-N
                      100 to                                 Current output                                    E5AN-Q3HMT-W-500-N
                                                                                                               E5AN-R3MTD-W-500-N
                      240 VAC Thermocouple                   Relay output       1

              Silver           or                 3          Voltage output     1
                               Resistance                    (for driving SSR)

                               thermometer

                                                             Relay output

                      24 VAC/                                Voltage output                                    E5AN-Q3MTD-W-500-N
                      VDC                                    (for driving SSR)

                                                             Current output                                    E5AN-C3MTD-W-500-N

Note: Models with analog inputs do not have temperature unit indicators.

                                                                                                                                      3
                                                                                                                    E5AN/E5EN

E5EN
Controllers with Terminal Blocks

              Case    Power                       Auxiliary                             Functions
              color   supply                      outputs
Size                  voltage     Input type                 Control output 1   Heater  Power supply  Control       Model
                                                                                                      output 2
                                                                                burnout for Sensor

                                                             Relay output                                           E5EN-R3MT-500-N

                                                             Voltage output                                         E5EN-Q3MT-500-N
                                                             (for driving SSR)

                                                             Current output                                         E5EN-C3MT-500-N

                                                             Relay output 1                                         E5EN-R3HMT-500-N

                                                             Voltage output     1                                   E5EN-Q3HMT-500-N
                                                             (for driving SSR)

                                                             Relay output 2                                         E5EN-R3HHMT-500-N

                                                             Voltage output     2                                   E5EN-Q3HHMT-500-N
                                                             (for driving SSR)

                               Thermocouple                  Relay output                             Voltage       E5EN-R3QMT-500-N
                                                                                                      output        E5EN-Q3QMT-500-N
                               or                 3          Voltage output
                               Resistance                    (for driving SSR)                        Voltage
                                                                                                      output
                               thermometer

                                                             Current output                           Voltage       E5EN-C3QMT-500-N
                                                             Relay output                             output

                      100 to                                                                          Long-life     E5EN-R3YMT-500-N
                      240 VAC                                                                         relay output

                                                             Voltage output                           Long-life     E5EN-Q3YMT-500-N
                                                             (for driving SSR)                        relay output

                                                             Current output                           Long-life     E5EN-C3YMT-500-N
                                                             Relay output                             relay output
              Black
                                                                                        Sensor Power                E5EN-R3PMT-500-N

                                                             Voltage output             Sensor Power                E5EN-Q3PMT-500-N
                                                             (for driving SSR)

                                                             Relay output                                           E5EN-R3ML-500-N

1/8 DIN                        Analog                        Voltage output                                         E5EN-Q3ML-500-N
48 96 78                   (current/voltage)             (for driving SSR)
(W H D)                                                                                                         E5EN-C3ML-500-N
                                                             Current output                                         E5EN-R3HML-500-N
                                                  3
                                                             Relay output 1

                                                                                     1                              E5EN-Q3HML-500-N
                                                             Voltage output
                                                             (for driving SSR)                        Long-life     E5EN-Q3YML-500-N
                                                                                                      relay output

                                                             Relay output                                           E5EN-R3MTD-500-N

                                                             Voltage output                                         E5EN-Q3MTD-500-N
                                                             (for driving SSR)

                               Thermocouple                  Current output                                         E5EN-C3MTD-500-N
                                                                                                                    E5EN-R3HMTD-500-N
                      24 VAC/ or                  3          Relay output 1
                                                                                                                    E5EN-Q3HMTD-500-N
                      VDC      Resistance                    Voltage output
                                                             (for driving SSR)
                               thermometer                                      1

                                                             Relay output 2                                         E5EN-R3HHMTD-500-N

                                                             Voltage output     2                                   E5EN-Q3HHMTD-500-N
                                                             (for driving SSR)

                                                             Relay output                                           E5EN-R3MT-W-500-N

                      100 to                                 Voltage output                                         E5EN-Q3MT-W-500-N
                      240 VAC                                (for driving SSR)                                      E5EN-C3MT-W-500-N
                                                                                                                    E5EN-R3HMT-W-500-N
                                                             Current output                                         E5EN-Q3HMT-W-500-N
                                                                                                                    E5EN-R3MTD-W-500-N
                               Thermocouple                  Relay output 1                                         E5EN-Q3MTD-W-500-N

              Silver           or                 3          Voltage output     1
                               Resistance                    (for driving SSR)

                               thermometer

                      24 VAC/                                Relay output
                      VDC
                                                             Voltage output
                                                             (for driving SSR)

                                                             Current output                                         E5EN-C3MTD-W-500-N

Note: Models with analog inputs do not have temperature unit indicators.

                                                                                                                                        4
                                                                                                                E5AN/E5EN

Option Units                                              Function                           Model
                                  RS-232C communications                                   E53-EN01
                            Name  RS-485 communications                                    E53-EN03
Communications Unit              Event inputs                                             E53-AKB
Event Input Unit

Accessories (Order Separately)                                 Current Transformers (CTs)                        Model
                                                                                                                E54-CT1
USB-Serial Conversion Cable                                             Hole diameter                           E54-CT3
                                                                             5.8 dia.
                                         Model                              12.0 dia.
                                      E58-CIFQ1

Terminal Cover

Connectable models                Model                        CX-Thermo Support Software

E5AN                              E53-COV16                                                             Model
E5EN                                                                                               EST2-2C-MV4

Note: The Terminal Cover comes with the E5CN-@@@-500 models.

Waterproof Packing

Connectable models                Model

E5AN                              Y92S-P4

E5EN                              Y92S-P5

Note: The Waterproof Packing is included with the Controller.

                                                                                                                           5
                                                                                                                          E5AN/E5EN

Specifications

Ratings

Power supply voltage              No D in model number: 100 to 240 VAC, 50/60 Hz
                                  D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range           85% to 110% of rated supply voltage

Power                             100 to 240 VAC: 10 VA
consumption                       24 VAC/VDC: 5.5 VA (24 VAC)/4 W (24 VDC)

Sensor input                      Models with temperature inputs
                                    Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                                    Platinum resistance thermometer: Pt100 or JPt100
                                    Infrared temperature sensor: 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
                                    Voltage input: 0 to 50 mV

                                  Models with analog inputs
                                    Current input: 4 to 20 mA or 0 to 20 mA
                                    Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                   Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB.)

Control method                    ON/OFF control or 2-PID control (with auto-tuning)

          Relay output            SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
                                  10 mA

Control   Voltage output          Output voltage: 12 VDC 15% (PNP), max. load current: 40 mA,
output    (for driving SSR)       With short-circuit protection circuit: Max. load current of 21 mA for control output 2

          Current output          4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 10,000

          Long-life relay         SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply voltage: 75
          output                  to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA, leakage current: 5 mA
                                  max. (250 VAC, 60 Hz)

               Number of outputs  3
Auxiliary
output Output                     Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
                                  load: 5 V, 10 mA
               specifications

          Number of inputs 2

Event     External contact        Contact input: ON: 1 k max., OFF: 100 k min.
input     input specifications    Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
                                  Current flow: Approx. 7 mA per contact

External power supply for ES1B 12 VDC 10%, 20 mA, short-circuit protection circuit provided

Setting method                    Digital setting using front panel keys

Indication method                 11-segment digital display and individual indicators (7-segments displays also possible)
                                  Character height: E5AN: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN: PV: 11.8 mm, SV: 8.1 mm, MV:
                                  5.8 mm
                                  Content of 3-level display: PV/SV/MV, PV/SV/multi-SP, or soak time remain *
                                  Number of digits: 4 for PV, SV, and MV

Multi SP                          Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial
                                  communications.

Bank switching                    Not supported.

Other functions                   Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
                                  detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
                                  protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic
                                  operations, PV/SV status display, simple program, automatic cooling coefficient adjustment

Ambient operating temperature -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C

Ambient operating humidity 25% to 85%

Storage temperature               -25 to 65C (with no condensation or icing)

* A 2-level display when shipped from the factory. A 3-level display is activated if parameters are initialized. For details on the third display level,
  refer to the User's Manual, Basic Type (Cat. No. H156).

                                                                                                                                                          6
                                                                                                                                                                                            E5AN/E5EN

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

Input                           Platinum resistance                                                    Thermocouple                                                               Infrared temperature    Analog
type                                 thermometer                                                                                                                                           sensor           input
                                                                                                                                                                                                             0 to
Name                                   Pt100         JPt100               K           J        T       EL                 U       N      R  S  B    W                       PL    10 to  60 to  115  140   50 mV
                                                                                                                                                                             II   70C   120
                                                                                                                                                                                          C     to   to  Usable
                                                                                                                                                                                                165  260  in the
                                                                                                                                                                                                C   C   following
                                                                                                                                                                                                          ranges
                        2300                                                                                                                                          2300                                by
                        1800                                                                                                                                1800                                          scaling:
                        1700                                                                                                             1700 1700                                                        -1999 to
                                                                                                                                                                                                          9999 or
                        1600                                                                                                                                                                              -199.9
                                                                                                                                                                                                          to 999.9
                        1500
                                                                                                                                                                                                              23
                        1400                                        1300                                                          1300                                      1300
                        1300
Temperature range (C)
                        1200

                        1100

                        1000                                                     850                             850
                                  850

                         900

                        800

                        700                                                                            600

                        600            500.0         500.0                500.0

                        500                                                           400.0 400 400.0                  400 400.0

                        400                                                                                                                                                                          260

                        300                                                                                                                                                              120 165

                        200                   100.0          100.0                                                                                                                90

                        100                                                                                                                    100

                        0                     0.0            0.0                                                                         0  0       0                       0     0      0      0    0

                        -100.0                                            -20.0 -100 -20.0                       -100

                        -200.0  -200 -199.9          -199.9         -200                       -200 -199.9 -200        -200 -199.9 -200

Setting                         0      1      2      3       4      5        6   7          8  9 10 11 12 13 14 15 16 17 18 24 25 19 20 21 22
number

Shaded settings are the default settings.                                                                              JPt100: JIS C 1604-1989, JIS C 1606-1989
The applicable standards for the input types are as follows:                                                           Pt100: JIS C 1604-1997, IEC 751
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1                                                                     PL II: According to Platinel II electromotive force charts from BASF (previously
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985                                                                                                    Engelhard)
W: W5Re/W26Re, ASTM E988-1990

Models with Analog Inputs

                        Input type                           Current                                   Voltage

Input specification 4 to 20mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V

Setting range                                    Usable in the following ranges by scaling:
                                                 -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or -1.999 to 9.999

Setting number 0                                                    1                    2        3                    4

Shaded settings are the default settings.

                                                                                                                                                                                                                     7
                                                                                                                                      E5AN/E5EN

Alarm Outputs

Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
        following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
        failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).

                                                             Alarm output operation

Set value               Alarm type              When alarm value When alarm value                                    Description of function

                                                    X is positive               X is negative

0          Alarm function OFF                   Output OFF                                                 No alarm
1 *1       Upper- and lower-limit
                                                ON           LH                                            Set the deviation in the set point by setting the alarm
                                                OFF                                                        upper limit (H) and alarm lower limit (L).
                                                             SP            *2

                                                ON               X              ON   X                     Set the upward deviation in the set point by setting
                                                OFF          SP                                            the alarm value (X).
2          Upper-limit                                                          OFF
                                                                                                    SP

                                                ON           X                  ON       X                 Set the downward deviation in the set point by setting
                                                                                OFF  SP                    the alarm value (X).
3          Lower-limit                          OFF
                                                                    SP

                                                ON           LH                                            Set the deviation in the set point by setting the alarm
                                                OFF                                                        upper limit (H) and alarm lower limit (L).
4 *1       Upper- and lower-limit range                                    *3

                                                             SP

           Upper- and lower-limit with          ON           LH                                            A standby sequence is added to the upper- and
           standby sequence                                                                                lower-limit alarm (1). *6
5 *1                                            OFF                        *4
                                                                    SP

                                                *5

                                                ON                      X       ON   X                     A standby sequence is added to the upper-limit alarm
                                                OFF                                                        (2). *6
6          Upper-limit with standby sequence                                    OFF
                                                                                                    SP
                                                             SP

                                                ON           X                  ON       X                 A standby sequence is added to the lower-limit alarm
                                                OFF                             OFF  SP                    (3). *6
7          Lower-limit with standby sequence

                                                             SP

                                                ON                X             ON      X                  The alarm will turn ON if the process value is larger
                                                OFF          0
8          Absolute-value upper-limit                                           OFF                        than the alarm value (X) regardless of the set point.

                                                                                                        0

9          Absolute-value lower-limit           ON                X             ON      X                  The alarm will turn ON if the process value is smaller
                                                OFF          0
                                                                                OFF                        than the alarm value (X) regardless of the set point.
                                                                                                        0

           Absolute-value upper-limit with      ON                X             ON      X                  A standby sequence is added to the absolute-value
           standby sequence                     OFF          0
10                                                                              OFF                        upper-limit alarm (8). *6

                                                                                                        0

           Absolute-value lower-limit with      ON                X             ON      X                  A standby sequence is added to the absolute-value
           standby sequence                     OFF          0
11                                                                              OFF                        lower-limit alarm (9). *6

                                                                                                        0

12         LBA (alarm 1 type only)                                         ---                             *7

13         PV change rate alarm                                            ---                             *8

*1. With set values 1, 4 and 5, the upper and lower limit values can                 *5. Set value: 5, Upper- and lower-limit with standby sequence
     be set independently for each alarm type, and are expressed as                       Always OFF when the upper-limit and lower-limit hysteresis

     "L" and "H."                                                                         overlaps.
*2. Set value: 1, Upper- and lower-limit alarm                                       *6. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature

      Case 1           Case 2           Case 3 (Always ON)   H < 0, L < 0                 Controllers User's Manual Basic Type (Cat. No. H156) for
                                             H SP L
             L H SP      SP L H                              H < 0, L > 0                 information on the operation of the standby sequence.
         H < 0, L > 0     H > 0, L < 0     H L SP            H  L                    *7. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
         H < L            H > L                    SP H L    H > 0, L < 0
                                                             H  L                         Controllers User's Manual Basic Type (Cat. No. H156) for

*3. Set value: 4, Upper- and lower-limit range                                            information on the loop burnout alarm (LBA).
                                                                                     *8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature

                                                                                          Controllers User's Manual Basic Type (Cat. No. H156) for

                                                                                          information on the PV change rate alarm.

      Case 1           Case 2           Case 3 (Always OFF)  H < 0, L < 0
                                               H SP L
             L H SP      SP L H                              H < 0, L > 0
        H < 0, L > 0      H > 0, L < 0      H L SP           H  L
         H < L            H > L

                                                             H > 0, L < 0

                                                SP H L       H  L

*4. Set value: 5, Upper- and lower-limit with standby sequence
     For Upper- and Lower-Limit Alarm Described Above

    Case 1 and 2
     Always OFF when the upper-limit and lower-limit hysteresis
     overlaps.

    Case 3: Always OFF

                                                                                                                                                                    8
                                                                                                                        E5AN/E5EN

Characteristics

Indication accuracy         Thermocouple: (0.3% of indicated value or 1C, whichever is greater) 1 digit max. *1
                            Platinum resistance thermometer: (0.2% of indicated value or 0.8C, whichever is greater) 1 digit max.
                            Analog input: 0.2% FS 1 digit max.
                            CT input: 5% FS 1 digit max.

Transfer output accuracy 0.3% FS max.

Influence of temperature    Thermocouple input (R, S, B, W, PL II): (1% of PV or 10C, whichever is greater) 1 digit max.
*2                          Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. *3
                            Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max.
Influence of voltage *2     Analog input: (1%FS) 1 digit max.

Input sampling period 250 ms

Hysteresis                  Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1
                            EU) *4
                            Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS)

Proportional band (P)       Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1
                            EU) *4
                            Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I)           0 to 3999 s (in units of 1 s)

Derivative time (D)         0 to 3999 s (in units of 1 s) *5

Control period              0.5, 1 to 99 s (in units of 1 s)

Manual reset value          0.0 to 100.0% (in units of 0.1%)

Alarm setting range         -1999 to 9999 (decimal point position depends on input type)

Affect of signal source Thermocouple: 0.1C/ max. (100  max.)

resistance                  Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance       20 M min. (at 500 VDC)

Dielectric strength         2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

Vibration Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions

Shock       Malfunction 100 m/s2, 3 times each in X, Y, and Z directions

resistance Destruction 300 m/s2, 3 times each in X, Y, and Z directions

Weight      E5AN            Controller: Approx. 310 g, Mounting Bracket: Approx. 100 g
            E5EN            Controller: Approx. 260 g, Mounting Bracket: Approx. 100 g

Degree of protection        Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection           Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                  CX-Thermo version 4.0 or higher

Setup Tool port             Provided on the bottom of the E5AN and E5EN.
                            An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN and E5EN *6

                 Approved   UL 61010-1, CSA C22.2 No. 1010-1
                 standards  EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *7
Standards
                 Conformed
                 standards

                            EMI:                                                 EN 61326

                            Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                            Noise Terminal Voltage:                              EN 55011 Group 1, class A

                            EMS:                                                 EN 61326

                            ESD Immunity:                                        EN 61000-4-2

EMC                         Electromagnetic Field Immunity:                      EN 61000-4-3

                            Burst Noise Immunity:                                EN 61000-4-4

                            Conducted Disturbance Immunity:                      EN 61000-4-6

                            Surge Immunity:                                      EN 61000-4-5

                            Power Frequency Magnetic Field Immunity:             EN 61000-4-8

                            Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

*1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U
     and L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max.

     is not specified. The indication accuracy of B thermocouples in the 400 to 800C range is 3C max. The indication accuracy of the R and S

     thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is 0.3 of PV or 3C,

     whichever is greater, 1 digit max. The indication accuracy of PL II thermocouples is 0.3 of PV or 2C, whichever is greater, 1 digit max.

*2. Ambient temperature: -10C to 23C to 55, Voltage range: -15% to 10% of rated voltage
*3. K thermocouple at -100C max.: 10C max.
*4. "EU" stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is C or F.
*5. When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s).
*6. External communications (RS-232C or RS-485) and cable communications for the Setup Tool can be used at the same time.
*7. Refer to information on maritime standards in Safety Precautions for E5@N/E5@N-H for compliance with Lloyd's Standards.

                                                                                                                                                    9
                                                                                                                                             E5AN/E5EN

USB-Serial Conversion Cable                                                 Current Transformer (Order Separately)
                                                                            Ratings
Applicable OS             Windows 2000, XP, or Vista

Applicable software       CX-Thermo version 4 or higher                     Dielectric strength 1,000 VAC for 1 min

Applicable models         E5AN/E5EN/E5CN/E5CN-U/E5AN-                       Vibration resistance 50 Hz, 98 m/s2
                          H/E5EN-H/E5CN-H/E5GN
                                                                                                                   E54-CT1: Approx. 11.5 g,
USB interface standard    Conforms to USB Specification 1.1.                Weight                                 E54-CT3: Approx. 50 g

DTE speed                 38400 bps                                         Accessories                            Armatures (2)
                                                                            (E54-CT3 only)                         Plugs (2)
                          Computer: USB (type A plug)
Connector specifications  Temperature Controller: Setup Tool                Heater Burnout Alarms, SSR Failure
                          port (on bottom of Controller)                    Alarms, and Heater Overcurrent Alarms

Power supply              Bus power (Supplied from USB host
                          controller.)
                                                                                                                      Models with detection for single-
Power supply voltage      5 VDC                                                                                       phase heaters: One input
                                                                                                                      Models with detection for single-
Current consumption       70 mA                                             CT input (for heater                      phase or three-phase heaters: Two
                                                                            current detection)                        inputs

Ambient operating         0 to 55C (with no condensation or
temperature               icing)

Ambient operating humidity 10% to 80%                                       Maximum heater current 50 A AC

Storage temperature       -20 to 60C (with no condensation                 Input current indication                  5% FS 1 digit max.
                          or icing)                                         accuracy

Storage humidity          10% to 80%                                        Heater burnout alarm                      0.1 to 49.9 A (in units of 0.1 A)
                                                                            setting range *1                          Minimum detection ON time: 100 ms
Altitude                  2,000 m max.
                                                                            SSR failure alarm setting 0.1 to 49.9 A (in units of 0.1 A)
Weight                    Approx. 100 g
                                                                            range *2                                  Minimum detection OFF time: 100 ms

Note: A driver must be installed in the personal computer. Refer to         Heater overcurrent alarm 0.1 to 49.9 A (in units of 0.1 A)
        installation information in the operation manual for the
        Conversion Cable.                                                   setting range *3                          Minimum detection ON time: 100 ms

Communications Specifications                                               *1. For heater burnout alarms, the heater current will be measured
                                                                                 when the control output is ON, and the output assigned to the
Transmission line         RS-485: Multipoint                                     alarm 1 function will turn ON if the heater current is lower than the
connection method         RS-232C: Point-to-point                                set value (i.e., heater burnout detection current value).

Communications            RS-485 (two-wire, half duplex) or RS-             *2. For SSR failure alarms, the heater current will be measured when
                          232C                                                   the control output is OFF, and the output assigned to the alarm 1
                                                                                 function will turn ON if the heater current is higher than the set
Synchronization method Start-stop synchronization                                value (i.e., SSR failure detection current value).

Protocol                  CompoWay/F, SYSWAY, or Modbus                     *3. For heater overcurrent alarms, the heater current will be
                                                                                 measured when the control output is ON, and the output assigned
Baud rate                 1200, 2400, 4800, 9600, 19200, 38400,                  to the alarm 1 function will turn ON if the heater current is higher
                          or 57600 bps                                           than the set value (i.e., heater overcurrent detection current
                                                                                 value).

Transmission code         ASCII                                             Electrical Life Expectancy Curve for
                                                                            Relays (Reference Values)
Data bit length *         7 or 8 bits

Stop bit length *         1 or 2 bits

Error detection           Vertical parity (none, even, odd)                 Life ( 104 operations)  500
                          Frame check sequence (FCS) with                                            300
                          SYSWAY
                          Block check character (BCC) with                                           100           E5AN/E5EN
                          CompoWay/F or CRC-16 Modbus
                                                                                                                   250 VAC, 30 VDC

Flow control              None                                                                                     (resistive load)

                                                                                                     50            cos = 1

Interface                 RS-485, RS-232C                                                            30

Retry function            None

Communications buffer 217 bytes                                                                      10
                                                                                                      5
Communications            0 to 99 ms                                                                  3
response wait time        Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can
  be individually set using the Communications Setting Level.

                                                                                                     1

                                                                                                          0  1  2  3  4              5  6

                                                                                                                      Switching current (A)

                                                                            Note: Do not connect a DC load to a Controller with a Long-life Relay
                                                                                    Output.

                                                                                                                                                          10
                                                                                                                                 E5AN/E5EN

External Connections

A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
  do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the
  measured temperature values as a result of leakage current.
  The voltage output (control output 2, for driving SSR) has basic insulation provided for the internal circuit.

Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose.

Controllers                                                                                          Option Units

100 to 240 VAC            The E5@N-@@@T@ is set for a K-type thermocouple                                          Communications  E53-AKB
24 VAC/VDC (no polarity)  (input type = 5) by default. An input error (s.err) will                                                 Event inputs
                            occur if the input type setting does not agree with the                  E53-EN01 E53-EN03
  Control output 1          temperature sensor. Check the input type.                                RS-232C RS-485

Relay output                                                                                        11 SD             11 B (+)      11
250 VAC, 5A                                                                                         12 RD
  (resistive load)                                       1          Event Inputs                     13 SG             12 A (-)      12  EV2
Voltage output          Input power supply                  11                                                                                    EV
(for driving SSR)
  12 VDC, 40 mA                                          2  12  EV2                                                    13 DO NOT USE 13 CT1/CT2
Current output
  0 to 20 mA DC                                          3           EV1
  4 to 20 mA DC             Control output 1
  Load: 600  max.                                           13                                External Power Supply
                                                         4          CT1/CT2 Control Output 2
  Control output 2                                                                              External power supply
                                                         5  14                                        12 VDC, 20 mA
Voltage output            Auxiliary output 3
(for driving SSR)                                               CT1 Control output 2           DO NOT
                                                         6                                     USE
      12 VDC, 21 mA                                         15
                                                         7
Long-life relay output    Auxiliary output 2                16  CT2 DO NOT
250 VAC, 3 A
(resistive load)                                         8                 USE

                                                         9         DO NOT
                          Auxiliary output 1                17 USE

                                                        10  18 DO NOT A               DO NOT
                                                                   USE
                                                                                   B  USE     mA

                                                            19                                       A heater burnout alarm, heater short alarm,
                                                                                                     heater overcurrent alarm, or input alarm is
                                                            20             B             V DO NOT    sent to the output to which the alarm 1
                                                                                                USE  function is assigned.
                                                                TC/Pt
                                                                universal-input       Analog input

Auxiliary output
      1, 2, 3

Relay outputs

250 VAC, 3 A

(resistive load)

                                                                                                                                                       11
Nomenclature                                                                                                                                  E5AN/E5EN

E5AN                                                                                                              E5EN

                      Temperature unit

                                    SUB1                                PV                                        Operation indicators  SUB1 SUB2
                                    SUB2                                                                             Temperature unit   HA SUB3
                                    SUB3                                                  No.1 display
Operation indicators                HA                                                                                                                           PV
                                                                                                                                                                          No.1 display

                                                                        SV                                                                                       SV  No.2 display

                                                                                         No. 2 display

                                    OUT1  STOP                          MV        No. 3 display                                         OUT1 STOP                MV  No.3 display
                                                                                                                                        OUT2 CMW MANU
                                    OUT2  CMW MANU                                                                Operation indicators

Programmable                                                                                                      Mode Key                                           Up Key
Function Key/                                                                                                     Level Key
Auto/Manual Key            PF                                                      Up Key                                                              PF            Programmable
                                                                                  Down Key
                               A/M                                                                                                                     A/M           Function Key/

                      E5AN                                                                                                                                           Auto/Manual Key

                                                                                                                                        E5EN

                      Level Key                         Mode Key                                                                                       Down Key

* A 2-level display when shipped from the factory. A 3-level display is activated if parameters are initialized. For details on the third display level,
  refer to the User's Manual, Basic Type (Cat. No. H156).

Dimensions                                                                                                                                                           (Unit: mm)

E5AN

                                                                                                                  Mounted Separately                         Group Mounted

                                                                                                                              92+00.8                  (96 number of units - 3.5)+01.0

                                                     6            79.2                                                                                                                                   92+00.8

                                                             2

96 96                                         112                               91                    120 min.                                 Group mounting does not allow waterproofing.

                                                                                                                                        92+00.8    Recommended panel thickness is 1 to
                                                                                                                                                    8 mm.
                                                Waterproof      Mounting Bracket  Terminal Cover
                                                Packing         (Accessory)       (E53-COV16)                                                       Group mounting is not possible in the
                                                (Accessory)                       (Accessory)                                                       vertical direction. (Maintain the specified
                                                                                                                                                    mounting space between Controllers.)
                                                                                  Crimp terminal size: M3.5
                                                                                                                                                    To mount the Controller so that it is
                                                                                                                                                    waterproof, insert the waterproof packing
                                                                                                                                                    onto the Controller.

                                                                                                                                                    When two or more Controllers are
                                                                                                                                                    mounted, make sure that the surrounding
                                                                                                                                                    temperature does not exceed the
                                                                                                                                                    allowable operating temperature specified
                                                                                                                                                    in the specifications.

                                                                                                                                                                                                                  12
                                                                                                                                E5AN/E5EN

E5EN                                                                                                  Mounted Separately Group Mounted

                                       6                                                                        45+00.6  (48 number of units - 2.5)+10.0

                                                       79.2

          48                                   2

                                                                                                                                        92+00.8

      96                          112                                          91

                                                                                                      120 min.                  Group mounting does not
                                                                                                                                allow waterproofing.

                                  Waterproof   Mounting Bracket  Terminal Cover                                                       92+00.8
                                  Packing      (Accessory)       (E53-COV16)
                                  (Accessory)                    (Accessory)                           Recommended panel thickness is 1 to 8 mm.
                                                                                                       Group mounting is not possible in the vertical direction.
                                                                 Crimp terminal size: M3.5
                                                                                                         (Maintain the specified mounting space between
                                                                                                         Controllers.)
                                                                                                       To mount the Controller so that it is waterproof, insert the
                                                                                                         waterproof packing onto the Controller.
                                                                                                       When two or more Controllers are mounted, make sure
                                                                                                         that the surrounding temperature does not exceed the
                                                                                                         allowable operating temperature specified in the
                                                                                                         specifications.

Accessories (Order Separately)

USB-Serial Conversion Cable

E58-CIFQ1

                                                                                             (2,100)

                                                  250                              LED (SD)                              1,765

                                  USB connector (type A plug)                                LED (RD)                           Serial connector

Terminal Covers                                                       1.2 3.2
                                                           10
E53-COV16 (Six Covers provided.)               44.8

                                                                                                                                                                      13
                                                                                                                                                                                             E5AN/E5EN

Waterproof Packing                                                         Y92S-P5 (for DIN 48 96)                                 Order the Waterproof Packing separately if it becomes lost or
                                                                                                                                     damaged.
Y92S-P4 (for DIN 96 96)                                                                                                            The Waterproof Packing can be used to achieve an IP66 degree of
                                                                                                                                     protection.
                                                                                                                                     (Deterioration, shrinking, or hardening of the waterproof packing may
                                                                                                                                     occur depending on the operating environment. Therefore, periodic
                                                                                                                                     replacement is recommended to ensure the level of waterproofing
                                                                                                                                     specified in IP66. The time for periodic replacement depends on the
                                                                                                                                     operating environment. Be sure to confirm this point at your site.
                                                                                                                                     Consider one year a rough standard. OMRON shall not be liable for
                                                                                                                                     the level of water resistance if the customer does not perform periodic
                                                                                                                                     replacement.)
                                                                                                                                     The Waterproof Packing does not need to be attached if a waterproof
                                                                                                                                     structure is not required.

Current Transformers                                                       21                               2.8                      E54-CT1
                                                                                                                       7.5           Thru-current (Io) vs. Output Voltage
E54-CT1                                                                    15    5.8 dia.                                            (Eo) (Reference Values)

                                                               25 3                                                                  Maximum continuous heater current: 50 A (50/60 Hz)
                                                                                                                                     Number of windings: 4002
                                                                      10                                                             Winding resistance: 182

E54-CT3                                                                                             10.5                             Output voltage (Eo) V (r.m.s.)  100 V 50 Hz

                                                                  40 40  40                                                                                              10                                 Distortion
                                                                                             Two, 3.5 dia.                                                                  1                                 factor 10%
                                                                                                                                                                                  1 k
                                                                                                                                                                     100 mV                                   3%
                                                                                                                                                                                                          1%

                                                                           30                                                                                        10                         100

                                                                                                              2.36 dia.                                              1                       RL = 10
                                                                           30
                                                                                                                                                                     100 V
                                                                                            12 dia.
                                                                                                                                  9

                                                                                                                                                                     10

                                                                                                                                                                     1            10 100 mA 1         10  100 1,000 A

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                   Two, M3 (depth: 4)                                                E54-CT3
                           15                                                                                                        Thru-current (Io) vs. Output Voltage
                                                                                                                                     (Eo) (Reference Values)
                                                   30
                                                                                                                                     Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                                                                     (Maximum continuous heater current for an OMRON
                                                                                                                                     Temperature Controller is 50 A.)
                                                                                                                                     Number of windings: 4002
                                                                                                                                     Winding resistance: 80.8

E54-CT3 Accessory                                                          Connection Example                                        Output voltage (Eo) V (r.m.s.)  100 V 50 Hz                             Distor-
                                                                                                                                                                        10                                   tion
Armature                                                                                Armature                                                                       1        1 k                       factor
                                                                                                                                                                                                             10%
Approx. 3 dia.                                                            Plug                                                                                                   500
                                                                                                                                                                                                            3%
                                                                                                                                                                                                          1%

                                                                                                            Lead

Plug               18                                                                                                                                              100 mV                      100
                (22)                                                                                                                                                       10                   50
Approx. 6 dia.                                                                                                                                                              1
                                                                                                                                                                                                RL = 10

                                                                                                                                                                     100 V       10 100 mA  1        10  100 1,000 A

                                                                                                                                                                          10
                                                                                                                                                                             1

                                                                                                                                                                                                Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                              14
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2009.11
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2009 All Right Reserved.