Controllers 1/8DINTemp Cont

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Controllers
RoHS:N
Analog / Digital:Digital
类型:
Type:
Digital Temperature Controller
Display Type:11-Segment, 4 Digit
工作电源电压:
Operating Supply Voltage:
100 VAC to 240 VAC
Mounting:Bracket
大小:
Size:
48 mm x 96 mm
Features:Large white PV display thats easier to read easy to use
Number of Outputs:4
输出类型:
Output Type:
Control Output
系列:
Series:
E5EC/E5AC
商标:
Brand:
Omron Automation and Safety
Number of Inputs:3
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
E5ECCC4A5M005
单位重量:
Unit Weight:
8.818490 oz

E5EC-CC4A5M-005器件文档内容

New Product

Digital Temperature Controller

E5CC/E5EC/E5AC/E5DC

The new standard in temperature control is

higher in every respect

E5CC (48 × 48 mm) / E5EC (48 × 96 mm) / E5AC (96 × 96 mm)

E5DC (22.5 mm Wide, and DIN Track-mounting Type)

Large White PV Display That's Easier to Read.

Easy to Use, from Model Selection to Setup and Operation.

A Complete Range of I/O Capacities, Functions, and Performance.

Handles More Applications.

New Models That Mount to DIN Track and Are Ideal for HMI/PLC Connections.

                                                           22.5 mm Wide, and

48 × 48 mm   48 × 96 mm     96 × 96 mm         DIN Track-mounting Type

E5CC         E5EC           E5AC                                 E5DC

                                                                              1
   Digital Temperature Controller

   E5CC                           (48 × 48 mm)

   Large White PV Display That’s Easier to Read.

   Easy to Use, from Model Selection to

   Setup and Operation.

   A Complete Range of I/O Capacities,

   Functions, and Performance.

   Handles More Applications.

   • The white PV display with a height of 15.2 mm improves visibility.

   • High-speed sampling at 50 ms.                                                             48 × 48 mm

   • Models are available with up to 3 auxiliary outputs, up to 4 event                           E5CC

   inputs, a transfer output, and a remote SP input to cover a wide            Refer to your OMRON website for the most recent

   range of applications.                                                      information on applicable safety standards.

   • Short body with depth of only 60 mm.

   • Set up the Controller without wiring the power supply by                          Refer to Safety Precautions on page 50.

   connecting to the computer with a Communications Conversion

   Cable (sold separately). Setup is easy with the CX-Thermo (sold

   separately).

   • Easy connections to a PLC with programless communications. Use            component communications to link

   Temperature Controllers to each other.

   Main I/O Functions

   Sensor Input                                 E5CC

   Universal input

   • Thermocouple                                                              Dual displays: PV/SV        4-digit displays

   • Pt

   • Analog current/voltage

         Indication Accuracy                                                   Control Output 1

         • Thermocouple input:                                                 • Relay output

         ±0.3% of PV                                                           • Voltage output (for driving SSR)

         • Pt input: ±0.2% of PV                                               • Linear current output

         • Analog input:

         ±0.2% of FS                                                           Control Output 2

                                                                               • None

         Sampling Period                                                       • Voltage output (for  driving  SSR)

         • 50 ms

                                                                               Auxiliary Outputs

   Event Inputs                                                                •3

   • None                                  • PF (shift) Key

   •2                                      • Temperature status display

   •4                                      • Simple programming                Transfer Output

                                           • Independent heating and           • None

                                           cooling PID control                 •1

   Remote SP Input                         • Changed parameter display

   • None                                  • Display brightness setting

   •1

   Serial Communications

   • None

   • RS-485

   This datasheet is provided as a guideline for selecting products.

   Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

   to use the product.

   E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

   E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

2
                                                                                                                                                           E5CC

Model Number Legend and Standard Models

Model Number Legend

E5CC-@@         @ @ @ @ -@@@ (Example: E5CC-RX3A5M-000)
       −−       − − − − −−−
            A   BC  DE           F

                A                   B          C                 D         E             F

Model           Control outputs     No. of  Power             Terminal  Input                                                       Meaning

                1 and 2          auxiliary  supply               type      type          Options

                                 outputs    voltage

E5CC                                                                                                                                48 × 48 mm

                                                                                                            Control output 1                    Control output 2

            RX                                                                                                  Relay output                         None

            QX                                                                                                  Voltage output                       None

                                                                                                            (for driving SSR)

     *1 *3  CX                                                                                         Linear current output *2                      None

            QQ                                                                                                  Voltage output                  Voltage output

                                                                                                            (for driving SSR)                   (for driving SSR)

            CQ                                                                                         Linear current output *2                 Voltage output

                                                                                                                                                (for driving SSR)

                                 3                                                                              3 (one common)

                                            A                                                                   100 to 240 VAC

                                            D                                                                                       24 VAC/DC

                                                              5                                                 Screw terminals (with cover)

                                                                        M                                       Universal input

                                                                                                  HB alarm and  Communications      Event       Remote     Transfer

                                                                                                  HS alarm                          inputs      SP Input   output

                                                                                         000      ---           ---                 ---         ---        ---

                                                                                     *1  001      1             ---                          2  ---        ---

                                                                                                  2

                                                                                     *1  003      (for 3-phase  RS-485              ---         ---        ---

                                                                                                  heaters)

                                                                                     *3  004      ---           RS-485                       2  ---        ---

                                                                                         005      ---           ---                          4  ---        ---

                                                                                         006      ---           ---                          2             Provided.

                                                                                         007      ---           ---                          2  Provided.  ---

*1.  Options with HB and HS alarms (001 and 003) cannot be selected if a linear current output is selected for the control output.

*2.  The control output cannot be used as a transfer output.

*3.  Option 004 can be selected only when "CX" is selected for the control outputs.

Heating and Cooling Control

● Using Heating and Cooling Control

A Control Output Assignment

If there is no control output 2, an auxiliary output is used as the cooling control output.

If there is a control output 2, the two control outputs are used for heating and cooling.

(It does not matter which output is used for heating and which output is used for cooling.)

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                                      3
   E5CC

   Optional Products (Order Separately)

   USB-Serial Conversion Cable                                           Front Covers

                Model                                                    Type                        Model

            E58-CIFQ2                                                    Hard Front Cover         Y92A-48H

                                                                         Soft Front Cover         Y92A-48D

   Terminal Covers

                Model                                                    CX-Thermo Support Software

            E53-COV17                                                                      Model

            E53-COV23                                                    EST2-2C-MV4

   Note: The E53-COV10 cannot be used.                                   Note: CX-Thermo version 4.5 or higher is required for the E5CC.

   Refer to page 12 for the mounted dimensions.                          For the system requirements for the CX-Thermo, refer to

   Waterproof Packing                                                    information on the EST2-2C-MV4 on the OMRON website

                                                                         (www.ia.omron.com).

                Model

            Y92S-P8

   Note: This Waterproof Packing is provided with the Digital

   Temperature Controller.

   Current Transformers (CTs)

   Hole diameter                Model

   5.8 mm                      E54-CT1

   12.0 mm                     E54-CT3

   Adapter

                Model

            Y92F-45

   Note: Use this Adapter when the panel has already been prepared for

   an E5B@ Controller.

   Waterproof Cover

                Model

            Y92A-48N

   Mounting Adapter

                Model

            Y92F-49

   Note: This Mounting Adapter is provided with the Digital Temperature

   Controller.

   DIN Track Mounting Adapter

                Model

            Y92F-52

4
                                                                                                                                      E5CC

Specifications

Ratings

Power supply voltage                          A in model number: 100 to 240 VAC, 50/60 Hz

                                              D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range                       85% to 110% of rated supply voltage

                                              Models with option selection of 000: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or

Power consumption                                                                     1.6 W max. at 24 VDC

                                              All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC

                                              Temperature input

                                                 Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                                 Platinum resistance thermometer: Pt100 or JPt100

Sensor input                                     Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                              Analog input

                                                 Current input: 4 to 20 mA or 0 to 20 mA

                                                 Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                               Current input: 150 Ω max., Voltage input: 1 MΩ min.

                                              (Use a 1:1 connection when connecting the ES2-HB/THB.)

Control method                                ON/OFF control or 2-PID control (with auto-tuning)

              Relay output                    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,

Control                                       minimum applicable load: 5 V, 10 mA *

output        Voltage output                  Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit

              (for driving SSR)

              Linear current output           4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000*

Auxiliary     Number of outputs               3

output        Output specifications           SPST-NO relay outputs, 250 VAC, Models with 3 outputs: 2 A (resistive load),

                                              Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V

              Number of inputs                2 or 4 (depends on model)

Event input   External contact input          Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.

              specifications                  Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                                              Current flow: Approx. 7 mA per contact

Transfer      Number of outputs               1 (only on models with a transfer output)

output        Output specifications           Contact output: 4 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

                                              Linear voltage output: 1 to 5 VDC, load: 1 kΩ max, resolution: Approx. 10,000

Setting method                                Digital setting using front panel keys

Remote SP input                               Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.)

                                              Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)

Indication method                             11-segment digital display and individual indicators

                                              Character height: PV: 15.2 mm, SV: 7.1 mm

Multi SP                                      Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or

                                              serial communications.

Bank switching                                None

                                              Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater

                                              burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital

Other functions                               filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,

                                              MV change rate limit, simple calculations, temperature status display, simple programming, moving

                                              average of input value, and display brightness setting

Ambient operating temperature                 -10 to 55°C (with no condensation or icing),

                                              for 3-year warranty: -10 to 50°C (with no condensation or icing)

Ambient operating humidity                    25% to 85%

Storage temperature                           -25 to 65°C (with no condensation or icing)

* You cannot select a relay output or linear  current output for control output 2.

                                                                                                                                                              5
   E5CC

   Input Ranges

   ●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

   Input type                         Platinum resistance                                                                 Thermocouple                                                  Infrared temperature

                                       thermometer                                                                                                                                             sensor

   Name                                Pt100          JPt100                K               J               T          E     L           U          N     R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                        70°C   120°C  165°C   260°C

                           2300                                                                                                                                             2300

                           1800                                                                                                                                       1800

                           1700                                                                                                                           1700  1700

                           1600

                           1500

                           1400                                       1300                                                                          1300                          1300

   Temperature range (°C)  1300

                           1200

                           1100

                           1000  850                                                  850                                    850

                           900

                           800

                           700                                                                                         600

                           600         500.0          500.0                    500.0

                           500                                                                 400.0  400      400.0               400      400.0

                           400                                                                                                                                                                                260

                           300                                                                                                                                                                 120    165

                           200                 100.0         100.0                                                                                                                      90

                           100                                                                                                                                        100

                           0                   0.0           0.0                                                                                          0     0           0     0     0      0      0       0

                           -100                                                -20.0  -100     -20.0                         -100

                           -200  -200  -199.9         199.9           -200                            -200     -199.9  -200        -200     -199.9  -200

   Setting                       0     1           2  3      4        5        6      7        8      9        10      11    12    13       14      15    16    17    18    19    20    21     22     23      24

   number

                           Shaded settings are the default settings.

   The applicable standards for the input types are as follows:

   K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                        JPt100: JIS C 1604-1989, JIS C 1606-1989

   L: Fe-CuNi, DIN 43710-1985                                                                  Pt100: JIS C 1604-1997, IEC 60751

   U: Cu-CuNi, DIN 43710-1985                                                                  PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

   W: W5Re/W26Re, ASTM E988-1990

   ●Analog input

   Input type                                      Current                                  Voltage

   Input                               4 to 20 mA     0 to 20 mA            1 to 5 V        0 to 5 V        0 to 10 V

   specification

                                       Usable in the following ranges by scaling:

   Setting range                       -1999 to 9999, -199.9 to 999.9,

                                       -19.99 to 99.99 or -1.999 to 9.999

   Setting number                              25            26                27              28              29

6
                                                                                                                                                   E5CC

Alarm Outputs

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)

Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

    To use alarm 1, set the output assignment to alarm 1.

Set                                                Alarm output operation

value          Alarm type              When alarm value X            When alarm value X                              Description of function

                                                is positive               is negative

0          Alarm function OFF                                Output OFF                         No alarm

                                                                                                Set the upward deviation in the set point for the alarm upper

                                           ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

1          Upper- and lower-limit *1       OFF               PV      *2                         lower limit (L). The alarm is ON when the PV is outside this

                                                   SP

                                                                                                deviation range.

2                                                        X                     X                Set the upward deviation in the set point by setting the alarm

           Upper-limit                     ON                        ON                         value (X). The alarm is ON when the PV is higher than the

(default)                                  OFF     SP        PV      OFF       SP          PV

                                                                                                SP by the deviation or more.

                                           ON      X                 ON              X          Set the downward deviation in the set point by setting the

3          Lower-limit                     OFF               PV      OFF                   PV   alarm value (X). The alarm is ON when the PV is lower than

                                                   SP                          SP               the SP by the deviation or more.

                                                                                                Set the upward deviation in the set point for the alarm upper

           Upper- and lower-limit          ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

4          range *1                        OFF               PV      *3                         lower limit (L). The alarm is ON when the PV is inside this de-

                                                   SP

                                                                                                viation range.

           Upper- and lower-limit          ON      L     H                                      A standby sequence is added to the upper- and lower-limit

5          with standby sequence *1        OFF               PV      *4                         alarm (1). *6

                                       *5          SP

           Upper-limit with standby        ON            X           ON        X

6          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the upper-limit alarm (2). *6

                                                   SP                          SP

           Lower-limit with standby        ON      X                 ON              X

7          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the lower-limit alarm (3). *6

                                                   SP                          SP

           Absolute-value upper-lim-       ON         X              ON           X             The alarm will turn ON if the process value is larger than the

8          it                              OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                0                                       0

                                           ON         X              ON           X             The alarm will turn ON if the process value is smaller than the

9          Absolute-value lower-limit      OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                0                                       0

           Absolute-value upper-lim-       ON         X              ON           X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence        OFF               PV      OFF                   PV   limit alarm (8). *6

                                                0                                       0

           Absolute-value lower-limit      ON         X              ON           X             A standby sequence is added to the absolute-value lower-

11         with standby sequence           OFF               PV      OFF                   PV   limit alarm (9). *6

                                                0                                       0

12         LBA (alarm 1 type only)                                -                             *7

13         PV change rate alarm                                   -                             *8

           SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

14         upper-limit alarm               OFF               SP      OFF                   SP   is higher than the alarm value (X).

                                                0                                       0

           SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

15         lower-limit alarm               OFF               SP      OFF                   SP   is lower than the alarm value (X).

                                                0                                       0

                                       Standard Control              Standard Control

                                           ON         X              ON           X

                                           OFF  0            MV      OFF                   MV

           MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated

16         upper-limit alarm *9        Heating/Cooling               Heating/Cooling            variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV)          Control (Heating MV)

                                           ON         X

                                           OFF  0            MV      Always ON

                                       Standard Control              Standard  Control

                                           ON         X              ON           X

                                           OFF  0            MV      OFF                0  MV

17         MV absolute-value           Heating/Cooling                                          This alarm type turns ON the alarm when the manipulated

           lower-limit alarm *9        Control (Cooling MV)          Heating/Cooling            variable (MV) is lower than the alarm value (X).

                                                                     Control (Cooling MV)

                                           ON         X

                                           OFF  0            MV      Always ON

           RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

18         upper-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is higher than the alarm value (X).

                                                0                                       0

           RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

19         lower-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is lower than the alarm value (X).

                                                0                                       0

                                                                                                                                                                  7
   E5CC

   *1  With set values 1, 4 and 5, the upper and lower limit values can be set       *4   Set value: 5, Upper- and lower-limit with standby sequence

       independently for each alarm type, and are expressed as “L” and “H.”               For Upper- and Lower-Limit Alarm Described Above *2

   *2  Set value: 1, Upper- and lower-limit alarm                                         • Case 1 and 2

       Case 1            Case 2                    Case 3 (Always ON)                     Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                          H<0, L<0        • Case 3: Always OFF

               L  H  SP  SP L    H                    H  SP    L

       H<0, L>0          H>0, L<0                                         H<0, L>0   *5.  Set value: 5, Upper- and lower-limit with standby sequence

       |H| < |L|         |H| > |L|                 H     L SP             |H| ≥ |L|       Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                          H>0, L<0   *6   Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                         SP H          L  |H| ≤ |L|       H174) for information on the operation of the standby sequence.

                                                                                     *7   Refer to the E5@C Digital Temperature Controllers User's Manual (Cat.

   *3  Set value: 4, Upper- and lower-limit range                                         No.H174)  for information on the loop burnout alarm (LBA).

       Case 1            Case 2     Case 3 (Always OFF)                              *8   Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                                          H<0, L<0        H174) for information on the PV change rate alarm.

       L          H  SP  SP L    H                    H  SP    L                     *9   When heating/cooling control is performed, the MV absolute upper limit

       H<0, L>0          H>0, L<0                                         H<0, L>0        alarm functions only for the heating operation and the MV absolute lower

       |H| < |L|         |H| > |L|                 H     L SP             |H| ≥ |L|       limit alarm functions only for the cooling operation.

                                                                          H>0, L<0   *10  This value is displayed only when a remote SP input is used. It functions in

                                                                  L       |H| ≤ |L|       both Local SP Mode and Remote SP Mode.

                                                         SP H

8
                                                                                                                                   E5CC

Characteristics

                                       Thermocouple:    (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1

Indication accuracy                    Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit

(at the ambient temperature of 23°C)   Analog input:    ±0.2% FS ±1 digit max.

                                       CT input:        ±5% FS ±1 digit max.

Transfer output accuracy               ±0.3% FS max.

Remote SP Input Type                   ±0.2% FS ±1 digit max.

Influence of temperature       *2      Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                                       Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *3

                                       Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

Influence of voltage   *2              Analog input: ±1%FS ±1 digit max.

                                       CT input: ±5% FS ±1 digit max.

                                       Remote SP      input: ±1% FS ±1 digit max.

Input sampling period                  50 ms

Hysteresis                             Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                       Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)                  Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                       Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D)                    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling      Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                       Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling          0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling        0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                         0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                     0.0 to 100.0% (in units of 0.1%)

Alarm setting range                    -1999 to 9999 (decimal point position depends on input type)

Influence of signal source resistance  Thermocouple: 0.1°C/Ω max. (100 Ωmax.)

                                       Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

Insulation resistance                  20 MΩ min. (at 500 VDC)

Dielectric strength                    2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction                10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

            Resistance                 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock       Malfunction                100 m/s2, 3 times each in X, Y, and Z directions

            Resistance                 300 m/s2, 3 times each in X, Y, and Z directions

Weight                                 Controller: Approx. 120 g, Mounting Bracket: Approx. 10 g

Degree of protection                   Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                      Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                             CX-Thermo version 4.5 or higher

Setup Tool port                        E5CC top panel:  An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port on

                                                        the computer. *5

            Approved standards         UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL), KOSHA certified (some models) *6, Korean

Standards                              Radio Waves Act (Act 10564)

            Conformed standards        EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *7

                                       EMI:                                                     EN61326

                                       Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                       Noise Terminal Voltage:                                  EN 55011 Group 1, class A

                                       EMS:                                                     EN 61326

EMC                                    ESD Immunity:                                            EN 61000-4-2

                                       Electromagnetic Field Immunity:                          EN 61000-4-3

                                       Burst Noise Immunity:                                    EN 61000-4-4

                                       Conducted Disturbance Immunity:                          EN 61000-4-6

                                       Surge Immunity:                                          EN 61000-4-5

                                       Voltage Dip/Interrupting Immunity:                       EN 61000-4-11

*1  The indication accuracy of K thermocouples in the -200 to 1300°C range, T and N thermocouples at a temperature of -100°C max., and U and

    L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is

    not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and

    S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C,

    whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3% of PV or ±2°C, whichever is greater, ±1 digit max.

*2  Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage

*3  K thermocouple at -100°C max.: ±10°C max.

*4  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5  External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.

*6  Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html

*7  Refer to information on maritime standards in Shipping Standards on page 52 for compliance with Lloyd's Standards.

                                                                                                                                                    9
E5CC

USB-Serial Conversion Cable                                                                                                      When Digital Temperature Controllers are con-

                                                                                                                                 nected, the parameters can be copied from the

    Applicable OS           Windows 2000, XP, Vista, or 7                                                                        Digital Temperature Controller that is set as the

    Applicable software     CX-Thermo version 4.5 or higher                                                                      master to the Digital Temperature Controllers that

                                                                                                                                 are set as slaves.

    Applicable models       E5@C Series and E5CB Series                                                                          Number of connected Digital Temperature Con-

    USB interface standard  Conforms to USB Specification 2.0.                Communications                                     trollers: 32 max. (including master)

    DTE speed               38400 bps                                         between components*                                When Digital Temperature Controllers are con-

                                                                                                                                 nected, set points and RUN/STOP commands

    Connector               Computer: USB (type A plug)                                                                          can be sent from the Digital Temperature Control-

    specifications          Digital Temperature Controller:                                                                      ler that is set as the master to the Digital Temper-

                            Special serial connector                                                                             ature Controllers that are set as slaves.

    Power supply            Bus power (Supplied from USB host controller.)*                                                      Slope and offsets can be set for the set point.

                                                                                                                                 Number of connected Digital Temperature Con-

    Power supply voltage    5 VDC                                                                                                trollers: 32 max. (including master)

    Current consumption     450 mA max.                                       MELSEC is a registered trademark of Mitsubishi Electric Corporation.

                            4.7±0.2 VDC                                       * A Temperature Controller with version 1.1 or higher is required.

    Output voltage          (Supplied from USB-Serial Conversion Cable to

                            the Digital Temperature Controller.)              Current Transformer (Order Separately)

                            250 mA max.                                       Ratings

    Output current          (Supplied from USB-Serial Conversion Cable to

                            the Digital Temperature Controller.)

    Ambient operating                                                         Dielectric strength                                1,000 VAC for 1 min

    temperature             0 to 55°C (with no condensation or icing)         Vibration resistance                               50 Hz, 98 m/s2

    Ambient operating       10% to 80%                                                                                           E54-CT1: Approx. 11.5 g,

    humidity                                                                  Weight                                             E54-CT3: Approx. 50 g

    Storage temperature     -20 to 60°C (with no condensation or icing)       Accessories                                        Armatures (2)

    Storage humidity        10% to 80%                                        (E54-CT3 only)                                     Plugs (2)

    Altitude                2,000 m max.

    Weight                  Approx. 120 g                                     Heater Burnout Alarms and SSR Failure

Windows is a registered trademark of Microsoft Corporation in the             Alarms

United States and or other countries.

* Use a high-power port for the USB port.                                                                                        Models with detection for singlephase

Note: A driver must be installed on the computer. Refer to the                CT input (for heater                               heaters: One input

    Instruction Manual included with the Cable for the installation           current detection)                                 Models with detection for singlephase or

    procedure.                                                                                                                   three-phase heaters: Two inputs

Communications Specifications                                                 Maximum heater                                     50 A AC

                                                                              current

    Transmission line       RS-485: Multidrop                                 Input current                                      ±5% FS ±1 digit max.

    connection method                                                         indication accuracy

    Communications          RS-485 (two-wire, half duplex)                    Heater burnout

    Synchronization                                                           alarm setting range                                0.1 to 49.9 A (in units of 0.1 A)

    method                  Start-stop synchronization                        *1                                                 Minimum detection ON time: 100 ms *3

    Protocol                CompoWay/F, or Modbus                             SSR failure alarm                                  0.1 to 49.9 A (in units of 0.1 A)

    Baud rate               19200, 38400, or 57600 bps                        setting range *2                                   Minimum detection OFF time: 100 ms *4

    Transmission code       ASCII                                             *1                       For heater burnout alarms, the heater current will be measured

    Data bit length*        7 or 8 bits                                                                when the control output is ON, and the output will turn ON if the

    Stop bit length*        1 or 2 bits                                                                heater current is lower than the set value (i.e., heater burnout

                            Vertical parity (none, even, odd)                                          detection current value).

    Error detection         Block check character (BCC) with                  *2                       For SSR failure alarms, the heater current will be measured when

                            CompoWay/F or CRC-16 Modbus                                                the control output is OFF, and the output will turn ON if the heater

    Flow control            None                                                                       current is higher than the set value (i.e., SSR failure detection

    Interface               RS-485                                                                     current value).

    Retry function          None                                              *3                       The value is 30 ms for a control period of 0.1 s or 0.2 s.

                                                                              *4                       The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Communications buffer   217 bytes

    Communications          0 to 99 ms                                        Electrical Life Expectancy Curve for

    response wait time      Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can    Relays (Reference Values)

    be individually set using the Communications Setting Level.               Life (× 104 operations)  500

Communications Functions                                                                               300

                            You can use the memory in the PLC to read and                              100

                            write E5@C parameters, start and stop operation,

                            etc. The E5@C automatically performs communi-                              50

                            cations with PLCs. No communications program-                              30

                            ming is required.

    Programless             Number of connected Temperature Controllers:

    communications*         32 max.                                                                    10

                            Applicable PLCs

                            OMRON PLCs                                                                 5

                                  SYSMAC CS Series, CJ Series, or                                              E5CC

                                  CP Series                                                            3       250 VAC, 30 VDC

                            Mitsubishi Electric PLCs                                                           (resistive load)

                                                                                                               cosφ = 1

                                  MELSEC Q Series or L Series                                          1

                                                                                                            0  1         2       3  4       5        6

                                                                                                                                    Switching current (A)

10
                                                                                                                                                                                             E5CC

External Connections

E5CC

Control output 1

Relay output                                                                                                 E5CC- @ @           3  @         5  M - @@@

250 VAC, 3A                                                                                                              (1)     (2) (3) (4) (5)             (6)

(resistive load)

Voltage output                                                                                                                                ↑

(for driving SSR)                                                               Auxiliary outputs 1 to 3                            Terminal type

12 VDC, 21 mA                                Control output 2                 Relay outputs

Linear current output                        Voltage output                   Models with 3 auxiliary             The E5CC is set for a K-type thermocouple (input type = 5) by

0 to 20 mA DC                                                                 outputs: 250 VAC, 2 A               default. An input error (s.err) will occur if the input type setting does

4 to 20 mA DC                                (for driving SSR)                (resistive load)

Load: 500 Ω max.                             12 VDC, 21 mA                                                        not agree with the temperature sensor. Check the input type.

(1) Control outputs 1, 2                                                         QQ

      RX                 QX                             CX                                                   CQ

Models with          Models with 1                  Models with               Models with 2            Models with 2 Outputs: Linear Current            (2) Auxiliary Outputs

1 Relay              Voltage Output                 1 Linear                  Voltage Outputs          Output and Voltage (for Driving SSR)                       Auxiliary outputs 1, 2, 3

Output               (for Driving SSR)              Current Output            (for Driving SSR)

1             OUT1   1          OUT1                1                   OUT1  1           OUT1            1           OUT1                                            7
                                                               +                       +Q                         +C                                                      Auxiliary output 3
              R              +  Q                                       C                                                                                             8
                             -
2                    2                              2          -              2        -  Q               2       -   Q                                                   Auxiliary output 2

3                    3                              3                         3        +  OUT2            3       +   OUT2                                            9   Auxiliary output 1

                                                                                                                                                                      10  ●  ●

                                                                                                       1          13         7

                                                                                                       2          14         8

(5) Sensor (Temperature/Analog) Input                                                                  3          15         9                          (3) Input Power Supply

      TC             Pt         I                   V                                                  4          16         10                         100 to 240 VAC          24 VAC/DC

          4       A  4       +  4                   4                                                  5          17         11

-                 B       mA                     -                                                     6          18         12                                   11                    11

          5       B  5       -  5                   5

          6          6          6             V     6                                                                                                             12                    12

+                                                +

                                                                                                                                                                                (no polarity)

(6) Options

001                             003                                        004                               005                              006                               007

Event Inputs 1                  Communications                             Communications                    Event Inputs                     Event Inputs                      Event Inputs

and 2, and CT1                  (RS-485), CT1,                             (RS-485), and                     1 to 4                           1 and 2, and                      1 and 2, and

                                and CT2                                    Event Inputs 3 and    4                                            Transfer Output                   Remote SP Input

              13                              B(+)  13                           B(+)     13                             13                                  13                                 13

              14                    RS-485          14                          RS-485    14                             14                                  14                                 14

   EV1                                        A(-)                               A(-)                             EV1                                   EV1                                EV1

EV2           15                                    15                                    15                 EV2         15                        EV2       15                      EV2        15

              16                                    16                                    16                             16                                  16           +      +              16

CT1           17                   CT1              17                                    17                             17                                  17       +V                V    +  17

                                              COM                                EV3                              EV3                                                                      mA

              18                CT2                 18                                    18                             18                                  18       I   -          -          18

                                                                                EV4                          EV4

Note: 1.  The application of the terminals depends on the model.

   2.     Do not wire the terminals that are shown with a gray background.

   3.     When complying with EMC standards, the cable that connects the sensor must be 30 m                                                  or less.

          If the cable length exceeds 30 m, compliance with EMC standards will not be possible.

   4.     Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Models with 3 Auxiliary Outputs

                          Sensor input, CT inputs, and remote SP input

                                Communications and event inputs

      Power                     Voltage output (for driving SSR),

      supply                 linear current output, and transfer output

                                                 Relay output

                                             Auxiliary outputs 1, 2, 3

                     : Reinforced insulation

                     : Functional isolation

Note: Auxiliary outputs 1 to 3 are not insulated.

                                                                                                                                                                                                    11
E5CC

Nomenclature

E5CC                                                        Front panel

                    Temperature unit

                    Operation indicators                                                     No. 1 display

                                                                                PV or specified parameter

                                                                                                                                                           Top View of E5CC

                                                                                                No. 2 display

                                                                                SP or specified parameter value

                                                                                                                     Top-panel Setup  Tool  port

                                                                                Use the U D Keys to set the

                                                                                parameter.

           Press O  Key once to go to Adjustment Level.                         Use S Key to change the digit (default setting).

           Press O  Key for at least 3 seconds to go to Initial Setting Level.

                                                                                Use the M Key to change to another parameter.

Dimensions                                                                                                                                                                   (Unit: mm)

Controllers

E5CC                                                                                                                                              Panel Cutout

                                          4                     73.1                                                 Mounted Separately                                      Group Mounted

                                                            60                                                                                                    (48 × number of units - 2.5)+10.0

                    48 × 48                              1

                                                                                                                                                                                            45+00.6

                                                                                44.8 × 44.8     48.8  58             60 min.                                      Group mounting does

                                                                                                                                                                  not allow waterproofing.

                                                                                                                                                  45+00.6

                    Waterproof Packing                   Mounting Adapter

                    (Accessory)                          (Accessory)            Terminal Cover                                45+00.6

                                                                                (E53-COV17)

                                                                                (Sold separately)              •  Recommended panel thickness is 1 to 5 mm.

                    The Setup Tool port is on the top of the Temperature Controller.                           •  Group mounting is not possible in the vertical direction. (Maintain

                    It is used to connect the Temperature Controller to the computer                              the specified mounting space between Controllers.)

                    to use the Setup Tool.                                                                     •  To mount the Controller so that it is waterproof, insert the

                    The E58-CIFQ2 USB-Serial Conversion Cable is required to                                      waterproof packing onto the Controller.

                    make the connection.                                                                       •  When two or more Controllers are mounted, make sure that the

                    Refer to the instructions that are provided with the USB-Serial                               surrounding temperature does not exceed the allowable operating

                    Conversion Cable for the connection procedure.                                                temperature specified in the specifications.

                    Note: Do not leave the USB-Serial Conversion Cable                                         •  To attach the USB-Serial Conversion Cable to the control panel,

                    connected when you use the Temperature Controller.                                            use a panel thickness of 1 to 2.5 mm.

Accessories (Order Separately)

● USB-Serial Conversion Cable

E58-CIFQ2

                                                                                                                     (2,110)          (13)                                                  (5) (15)

                                                                         250                                   (87)                                        1,740

                                                                                                      LED (RD)                                    (250)

                                          USB connector (type A plug)

                                                                                                                              LED (PWR)                                      Serial connector

                                                                                                                              LED (SD)

● Terminal Covers                         48                                    ● Terminal                           Covers

E53-COV17                                                                       E53-COV23                            (Three Covers                provided.)

                                                                                                                                            2     3.8

                    48.8

                                                                                                                              10

                                                                                                                                                                             Terminal Cover

                                                                                                                                                                             (E53-COV23)

                    22                                                                                               44.8

                    9.1

12
                                                                                                                                                                                                    E5CC

● Waterproof Packing                       The Waterproof Packing is provided with the Temperature Controller.

Y92S-P8 (for DIN 48 × 48)                  Order the Waterproof Packing separately if it becomes lost or damaged.

                                           The Waterproof Packing can be used to achieve an IP66 degree of protection.

                                           (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the

                                           operating environment. Therefore, periodic replacement is recommended to ensure the level of

                                           waterproofing specified in IP66. The time for periodic replacement depends on the operating

                                           environment. Be sure to confirm this point at your site.

                                           Consider three years a rough standard.)

                                           The Waterproof Packing does not need to be attached if a waterproof structure is not required.

● Current Transformers

E54-CT1                                                                             Thru-current (Io) vs. Output Voltage (Eo)

                                       21                            2.8

                                       15                                           (Reference Values)

                                                 5.8 dia.                           E54-CT1

                                                                            7.5

                                                                                    Maximum continuous heater current:                                                                        50 A (50/60 Hz)

                           25                                                       Number of windings:                                                                                       400±2

                                   3                                                Winding resistance:                                                                                       18±2 Ω

                                                           10.5

                                                                                                                    Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

                                       40

                                                   Two, 3.5 dia.                                                                                    10                          ∞                    Distortion

                                                                                                                                                                  1kΩ                                factor

                                                                                                                                                                                                     10%

                                   10                                                                                                               1

                                                                                                                                                                                                    3%

                                                                                                                                                                                                1%

                                       30                                                                                                           100mV

E54-CT3                                                                                                                                             10                                100Ω

                                                                 2.36 dia.

                                       30                                                                                                           1                                 RL=10Ω

                                                 12 dia.

                                                                                 9

                                                                                                                                                    100μV

                                                                                                                                                    10

                           40 × 40                                                                                                                         1  10  100mA            1        10      100     1,000A

                                                                                                                                                                                      Thru-current (Io) A (r.m.s.)

                                                                                    Thru-current (Io) vs. Output Voltage (Eo)

                                                 Two, M3 (depth: 4)                 (Reference Values)

                               15                                                   E54-CT3

                                                                                    Maximum continuous heater current:                                                                      120 A (50/60 Hz)

                                       30                                           (Maximum continuous heater current for an OMRON

                                                                                    Digital Temperature Controller is 50 A.)

E54-CT3 Accessories                                                                 Number of windings:                                                                                     400±2

•  Armature                            Connection  Example                          Winding resistance:                                                                                     8±0.8 Ω

                                                                                    Output voltage (Eo) V (r.m.s.)                                  100V     Frequency: 50 Hz

                                                           Armature                                                                                                                                      Distortion

Approx. 3 dia.                             Plug                                                                                                     10                          ∞                        factor

                                                                                                                                                                  1kΩ                                    10%

                                                                          Lead                                                                                    500Ω                                   3%

                                                                                                                                                    1                                                   1%

                      18                                                                                            100mV

                                                                                                                                                                                      100Ω

• Plug                                                                                                                                              10                                50Ω

                                                                                                                                                                                      RL=10Ω

Approx. 6 dia.                                                                                                                                      1

                                                                                                                    100μV

                (22)

                                                                                                                                                    10

                                                                                                                                                          1   10  100mA            1        10      100  1,000A

                                                                                                                                                                                      Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                     13
E5CC

● Adapter

Y92F-45    Note: 1.      Use this Adapter when the Front Panel has already been prepared for the E5B@.

                     2.  Only black is available.

                     3.  You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you use the Y92F-45 Adapter. To use the USB-Serial

                         Conversion Cable to make the settings, do so before you mount the Temperature Controller in the panel.

                                                                                                                         Fixture (Accessory)

                                                                             4.7                        76

                                                                                             69.6 to 77.6

                                                   72 × 72

                                                                                                                              67 × 67 87

Mounted to E5CC                                                              Panel (1 to 8 mm)              Mounting Adapter

                                                   72 × 72                                                  Y92F-30

                                                                                                            (Accessory)

                                                                    48 × 48

                                                                    2.2           4.7

                                                                                             62.8

                                                                                  To back of the E5CC

● DIN Track Mounting Adapter

Y92F-52    Note: This Adapter cannot be used together with the Terminal Cover.

                     Remove the Terminal Cover to use the Adapter.

                                                                                                                     This Adapter is used to mount the

                                                                                             61                      E5CC to a DIN Track.

                                                                                                                     If you use the Adapter, there is no

                                                                                                                     need for a plate to mount in the

                                                                                                                     panel or to drill mounting holes in

                                                                                                   3.5               the panel.

                                                   50                        38

    Mounted to E5CC

                                                            48

                                                                                       80.5

14
                                                                                                                                  E5CC

● Watertight    Cover                                                   ● Mounting    Adapter

Y92A-48N                                                                Y92F-49

                                    21.9  14                                                 The Mounting Adapter is provided with the

                                    (2)                                                      Temperature Controller.

                                                                                             Order this Adapter separately if it becomes

                                                                                             lost or damaged.

87.7      79.2                                69

                                              12

                       67.6

● Protective    Cover                                                   ● Protective  Cover

Y92A-48D        Note: This Protective Cover cannot be used              Y92A-48H

                             if the Waterproof Packing is installed.                         This Protective Cover is hard type.

                       This Protective Cover is soft type.                                   Please use it for the mis-operation

                       It is able to operate the controller with using                       prevention etc.

                       this cover.

                                                                                                                                          15
    Digital Temperature Controller

    E5EC/E5AC                                                          (48 × 96 mm/96 × 96 mm)

Large White PV Display That’s Easier to Read.

Easy to Use, from Model Selection to

Setup and Operation.

A Complete Range of I/O Capacities,

Functions, and Performance.

Handles More Applications.

    • A white LCD PV display with a height of approx. 18 mm for the

    E5EC and 25 mm for the E5AC improves visibility.

    • Tool ports are provided both on the top panel and the front panel.

    Set up the Controller without wiring the power supply by                        48 × 96 mm                    96 × 96 mm

    connecting to the computer with a Communications Conversion                     E5EC                           E5AC

    Cable (sold separately). Setup is easy with the CX-Thermo (sold

    separately).                                                                    Refer to your OMRON website for the most recent

    • High-speed sampling at 50 ms.                                                 information on applicable safety standards.

    • Models are available with up to 4 auxiliary outputs, up to 6 event

    inputs, a transfer output, and a remote SP input to cover a wide                     Refer to Safety Precautions on page 50.

    range of applications.

    • Short body with depth of only 60 mm.

    • Easy connections to a PLC with programless communications.

    Use component communications to link Temperature Controllers to each other.

    • The new position-proportional control models allow you to control valves as well.

Main I/O Functions

    Sensor Input                            E5EC                       E5AC

    Universal input

    • Thermocouple

    • Pt                                                                                 Three-level Display

    • Analog current/voltage                                                             PV, SV, and MV displayed                4-digit

                                                                                         at the same time.                       displays

          Indication Accuracy

          • Thermocouple input:                                                          Control Output 1

          ±0.3% of PV                                                                    • Relay output

          • Pt input: ±0.2% of PV                                                        • Voltage output (for driving SSR)

          • Analog input: ±0.2% of  FS                                                   • Linear current output

          Sampling Period

          • 50 ms                                                                        Control Output 2

                                                                                         • Voltage output (for driving SSR)

                                                                                         • Relay output

    Event Inputs                                                                         • Linear current output

    • None                                  • PF (shift) Key

    •2                                      • Setup Tool port on front panel             Auxiliary Outputs

    •4                                      • Temperature status display                 •4

    •6                                      • Simple programming

    Remote SP Input                         • Independent heating and                    Transfer Output

    • None                                  cooling PID control

    •1                                      • Changed parameter display                  • None

                                            • Display brightness setting                 •1

    Serial Communications

    • None

    • RS-485

    This datasheet is provided as a guideline for selecting products.

    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

    to use the product.

        E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

        E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

16
                                                                                                                                        E5EC/E5AC

Model Number Legend and Standard Models

Model Number Legend

E5EC-@@            @ @ @ @ -@@@ (Example: E5EC-RX4A5M-000)
           −−      − − − − −−−
            A      BC         DE       F

E5AC-@@            @ @ @ @ -@@@ (Example: E5AC-RX4A5M-000)
           −A−     − B − C −D − E −F−−

                           A                 B                 C        D         E   F

    Model          Control outputs        No. of auxil-     Power    Terminal  Input                                       Meaning

                        1 and 2              iary out-      supply      type   type   Options

                                             puts           voltage

E5EC                                                                                                              48 × 96 mm

E5AC                                                                                                              96 × 96 mm

                                                                                                         Control output 1               Control output 2

               RX                                                                                            Relay output                       None

               QX                                                                                        Voltage output                         None

                                                                                                         (for driving SSR)

           *2  CX                                                                                        Linear current output                  None

               QQ                                                                                        Voltage output                 Voltage output

                                                                                                         (for driving SSR)              (for driving SSR)

               QR                                                                                        Voltage output                    Relay output

                                                                                                         (for driving SSR)

               RR                                                                                            Relay output                  Relay output

           *2  CC                                                                                        Linear current output          Linear current out-

                                                                                                                                                put

           *2  CQ                                                                                        Linear current output          Voltage output

                                                                                                                                        (for driving SSR)

               PR                                                                              Position-proportional relay output       Position-proportion-

                                                                                                                                        al relay output

                                      *3  4                                                    4 (auxiliary outputs 1 and 2 with same common and auxilia-

                                                                                                         ry outputs 3 and 4 with same common)

                                                            A                                                100 to 240 VAC

                                                            D                                                     24 VAC/DC

                   Control outputs 1      and 2                      5                                       Screw terminals (with cover)

               For RX,                                                         M                             Universal input

               QX, QQ,     For CX or      For PR                                               HB alarm                         Event   Remote    Transfer

               QR, RR, or  CC                                                                  and           Communications     inputs  SP Input  output

               CQ                                                                              HS alarm

               Selectable  Selectable     Selectable                                  000           ---      ---                ---        ---        ---

Option                     Selectable     Selectable                                  004           ---      RS-485             2          ---        ---

selection                  Selectable                                                 005           ---      ---                4          ---        ---

conditions                                                                                          2

*1             Selectable                                                             009      (for 3-phase  RS-485             2          ---        ---

                                                                                               heaters)

               Selectable                                                             010           1        ---                4          ---        ---

               Selectable                                                             011           1        ---                6       Provided. Provided.

                           Selectable                                                 013           ---      ---                6       Provided. Provided.

                           Selectable     Selectable                                  014           ---      RS-485             4       Provided. Provided.

*1.  The options that can be selected depend on the type of control output.

*2.  The control output cannot be used as a transfer output.

*3.  A model with four auxiliary outputs must be selected.

Heating and Cooling Control

l    Using Heating and Cooling Control

A Control Output Assignment

If there is no control output 2, an auxiliary output is used as the cooling control output.

If there is a control output 2, the two control outputs are used for heating and cooling.

(It does not matter which output is used for heating and which output is used for cooling.)

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                              17
E5EC/E5AC

Optional Products (Order Separately)

USB-Serial Conversion Cable                                           Current Transformers (CTs)

                 Model                                                Hole diameter         Model

           E58-CIFQ2                                                  5.8 mm                E54-CT1

Communications Conversion Cable                                       12.0 mm               E54-CT3

                 Model                                                CX-Thermo Support Software

           E58-CIFQ2-E                                                               Model

Note: Always use this product together with the E58-CIFQ2.            EST2-2C-MV4

    This Cable is used to connect to the front-panel Setup Tool       Note: CX-Thermo version 4.5 or higher is required for the E5EC.

    port.                                                             For the system requirements for the CX-Thermo, refer to

Terminal Covers                                                       information on the EST2-2C-MV4 on the OMRON website

                                                                      (www.ia.omron.com).

                 Model

           E53-COV24

Waterproof Packing

    Applicable Controller    Model

    E5EC                     Y92S-P9

    E5AC                     Y92S-P10

Note: This Waterproof Packing is provided with the Digital

    Temperature Controller.

Waterproof Cover

    Applicable Controller    Model

    E5EC                     Y92A-49N

    E5AC                     Y92A-96N

Front Port Cover

                 Model

           Y92S-P7

Note: This Front Port Cover is provided with the Digital Temperature

    Controller.

Mounting Adapter

                 Model

           Y92F-51

Note: This Mounting Adapter is provided with the Digital Temperature

    Controller.

18
                                                                                                                      E5EC/E5AC

Specifications

Ratings

Power supply voltage                   A in model number: 100 to 240 VAC, 50/60 Hz

                                       D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range                85% to 110% of rated supply voltage

                                       Models with option selection of 000:6.6 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or

                                 E5EC                                          2.3 W max. at 24 VDC

Power consumption                      All other models: 8.3 VA max. at 100 to 240 VAC, and 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC

                                       Models with option selection of 000:7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or

                                 E5AC                                          2.4 W max. at 24 VDC

                                       All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC

                                       Temperature input

                                       Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                       Platinum resistance thermometer: Pt100 or JPt100

Sensor input                           Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                       Analog input

                                       Current input: 4 to 20 mA or 0 to 20 mA

                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                        Current input: 150 Ω max., Voltage input: 1 MΩ min.

                                       (Use a 1:1 connection when connecting the ES2-HB/THB.)

Control method                         ON/OFF or 2-PID control (with autotuning)

              Relay output             SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations,

                                       minimum applicable load: 5 V, 10 mA

Control       Voltage output           Output voltage: 12 VDC ±20% (PNP), max. load current: 40 mA, with short-circuit protection circuit

output        (for driving SSR)        (The maximum load current is 21 mA for models with two control outputs.)

              Linear current output    4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

Auxiliary     Number of outputs        4

output        Output specifications    SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load),

                                       Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V

              Number of inputs         2, 4 or 6 (depends on model)

Event input   External contact input   Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.

              specifications           Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                                       Current flow: Approx. 7 mA per contact

Transfer      Number of outputs        1 (only on models with a transfer output)

output        Output specifications    Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: Approx. 10,000

                                       Linear voltage output: 1 to 5 VDC, load: 1 kΩ max, Resolution: Approx. 10,000

Remote SP input                        Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.)

                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)

Potentiometer input                    100 Ω to 10 kΩ

Setting method                         Digital setting using front panel keys

                                       11-segment digital display and individual indicators

                                       Character height:  E5EC: PV: 18.0 mm, SV: 11.0 mm, MV: 7.8 mm

Indication method                                         E5AC: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm

                                       Three displays Contents: PV/SV/MV, PV/SV/Multi-SP, or PV/SV/Remaining soak time

                                       Numbers of digits: 4 digits each for PM, SV, and MV displays

Multi SP                               Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or

                                       serial communications.

Bank switching                         None

                                       Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater

                                       burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital

Other functions                        filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,

                                       MV change rate limit, simple calculations, temperature status display, simple programming, moving

                                       average of input value, and display brightness setting

Ambient operating temperature          -10 to 55°C (with no condensation or icing),

                                       for 3-year warranty: -10 to 50°C  (with no condensation or icing)

Ambient operating humidity             25% to 85%

Storage temperature                    -25 to 65°C (with no condensation or icing)

                                                                                                                                                       19
E5EC/E5AC

Input Ranges

●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Input type                         Platinum resistance                                                                     Thermocouple                                               Infrared temperature

                                        thermometer                                                                                                                                              sensor

    Name                                Pt100          JPt100                K               J               T              E  L           U          N     R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                          70°C   120°C  165°C   260°C

                            2300                                                                                                                                              2300

                            1800                                                                                                                                        1800

                            1700                                                                                                                            1700  1700

                            1600

                            1500

                            1400                                       1300                                                                           1300                          1300

    Temperature range (°C)  1300

                            1200

                            1100

                            1000  850                                                  850                                     850

                            900

                            800

                            700                                                                                         600

                            600         500.0          500.0                    500.0

                            500                                                                 400.0  400      400.0                400      400.0

                            400                                                                                                                                                                                 260

                            300                                                                                                                                                                  120    165

                            200                 100.0          100.0                                                                                                                      90

                            100                                                                                                                                         100

                            -100                0.0            0.0                                                                                          0     0           0     0     0      0      0       0

                            -200                                                -20.0  -100     -20.0                          -100

                                  -200  -199.9         -199.9          -200                            -200     -199.9  -200         -200     -199.9  -200

    Setting                       0     1       2      3       4       5        6      7        8      9        10      11     12    13       14      15    16    17    18    19    20    21     22     23      24

    range

                            Shaded settings are the default settings.

The applicable standards for the input types are as follows:

K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                            JPt100: JIS C 1604-1989, JIS C 1606-1989

L: Fe-CuNi, DIN 43710-1985                                                                      Pt100: JIS C 1604-1997, IEC 60751

U: Cu-CuNi, DIN 43710-1985                                                                      PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

W: W5Re/W26Re, ASTM E988-1990

●Analog input

    Input type                                      Current                                     Voltage

    Input                               4 to 20 mA     0 to 20 mA            1 to 5 V           0 to 5 V        0 to 10 V

    specification

                                        Usable in the following ranges by scaling:

    Setting range                       -1999 to 9999, -199.9 to 999.9,

                                        -19.99 to 99.99 or -1.999 to 9.999

    Setting number                              25             26               27                 28                   29

20
                                                                                                                                          E5EC/E5AC

Alarm type

Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)

Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.

    To use alarm 1, set the output assignment to alarm 1.

Set                                                Alarm output operation

value          Alarm type              When alarm value X            When alarm value X                              Description of function

                                                is positive               is negative

0          Alarm function OFF                                Output OFF                         No alarm

                                                                                                Set the upward deviation in the set point for the alarm upper

                                           ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

1          Upper- and lower-limit *1       OFF               PV      *2                         lower limit (L). The alarm is ON when the PV is outside this

                                                   SP

                                                                                                deviation range.

2                                                        X                     X                Set the upward deviation in the set point by setting the alarm

           Upper-limit                     ON                        ON                         value (X). The alarm is ON when the PV is higher than the

(default)                                  OFF     SP        PV      OFF       SP          PV

                                                                                                SP by the deviation or more.

                                           ON      X                 ON              X          Set the downward deviation in the set point by setting the

3          Lower-limit                     OFF               PV      OFF                   PV   alarm value (X). The alarm is ON when the PV is lower than

                                                   SP                          SP               the SP by the deviation or more.

                                                                                                Set the upward deviation in the set point for the alarm upper

           Upper- and lower-limit          ON      L     H                                      limit (H) and the lower deviation in the set point for the alarm

4          range *1                        OFF               PV      *3                         lower limit (L). The alarm is ON when the PV is inside this de-

                                                   SP

                                                                                                viation range.

           Upper- and lower-limit          ON      L     H                                      A standby sequence is added to the upper- and lower-limit

5          with standby sequence *1        OFF               PV      *4                         alarm (1). *6

                                       *5          SP

           Upper-limit with standby        ON            X           ON        X

6          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the upper-limit alarm (2). *6

                                                   SP                          SP

           Lower-limit with standby        ON      X                 ON              X

7          sequence                        OFF               PV      OFF                   PV   A standby sequence is added to the lower-limit alarm (3). *6

                                                   SP                          SP

           Absolute-value upper-lim-       ON         X              ON           X             The alarm will turn ON if the process value is larger than the

8          it                              OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                0                                       0

                                           ON         X              ON           X             The alarm will turn ON if the process value is smaller than the

9          Absolute-value lower-limit      OFF               PV      OFF                   PV   alarm value (X) regardless of the set point.

                                                0                                       0

           Absolute-value upper-lim-       ON         X              ON           X             A standby sequence is added to the absolute-value upper-

10         it with standby sequence        OFF               PV      OFF                   PV   limit alarm (8). *6

                                                0                                       0

           Absolute-value lower-limit      ON         X              ON           X             A standby sequence is added to the absolute-value lower-

11         with standby sequence           OFF               PV      OFF                   PV   limit alarm (9). *6

                                                0                                       0

12         LBA (alarm 1 type only)                                -                             *7

13         PV change rate alarm                                   -                             *8

           SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

14         upper-limit alarm               OFF               SP      OFF                   SP   is higher than the alarm value (X).

                                                0                                       0

           SP absolute-value               ON         X              ON           X             This alarm type turns ON the alarm when the set point (SP)

15         lower-limit alarm               OFF               SP      OFF                   SP   is lower than the alarm value (X).

                                                0                                       0

                                       Standard Control              Standard Control

                                           ON         X              ON           X

                                           OFF  0            MV      OFF                   MV

           MV absolute-value                                                            0       This alarm type turns ON the alarm when the manipulated

16         upper-limit alarm *9        Heating/Cooling               Heating/Cooling            variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV)          Control (Heating MV)

                                           ON         X

                                           OFF  0            MV      Always ON

                                       Standard Control              Standard  Control

                                           ON         X              ON           X

                                           OFF  0            MV      OFF                0  MV

17         MV absolute-value           Heating/Cooling                                          This alarm type turns ON the alarm when the manipulated

           lower-limit alarm *9        Control (Cooling MV)          Heating/Cooling            variable (MV) is lower than the alarm value (X).

                                                                     Control (Cooling MV)

                                           ON         X

                                           OFF  0            MV      Always ON

           RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

18         upper-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is higher than the alarm value (X).

                                                0                                       0

           RSP absolute-value              ON         X              ON           X             This alarm type turns ON the alarm when the remote SP

19         lower-limit alarm *10           OFF               RSP     OFF                   RSP  (RSP) is lower than the alarm value (X).

                                                0                                       0

                                                                                                                                                                  21
E5EC/E5AC

*1   With set values 1, 4 and 5, the upper and lower limit values can be set       *4.  Set value: 5, Upper- and lower-limit with standby sequence

     independently for each alarm type, and are expressed as “L” and “H.”                  For Upper- and Lower-Limit Alarm Described Above *2

*2.  Set value: 1, Upper- and lower-limit alarm                                         • Case 1 and 2

     Case 1         Case 2                       Case 3 (Always ON)                        Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                        H<0, L<0

     L       H  SP  SP L    H                       H  SP    L                          •  Case 3: Always OFF

     H<0, L>0       H>0, L<0                                            H<0, L>0   *5.  Set value: 5, Upper- and lower-limit with standby sequence

     |H| < |L|      |H| > |L|                    H     L SP             |H| ≥ |L|       Always OFF when the upper-limit and lower-limit hysteresis overlaps.

                                                                        H>0, L<0   *6.  Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                       SP H          L  |H| ≤ |L|       H174) for information on the operation of the standby sequence.

*3.  Set value: 4, Upper- and lower-limit range                                    *7.  Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

                                                                                        H174) for information on the PV change rate alarm. This setting cannot be

     Case 1         Case 2     Case 3 (Always OFF)                                      used with a position-proportional model.

                                                                        H<0, L<0   *8.  Refer to the E5@C Digital Temperature Controllers User's Manual (Cat. No.

     L       H  SP  SP L    H                       H  SP    L                          H174) for information on the PV change rate alarm.

     H<0, L>0       H>0, L<0                                            H<0, L>0   *9.  When heating/cooling control is performed, the MV absolute upper limit

     |H| < |L|      |H| > |L|                    H     L SP             |H| ≥ |L|       alarm functions only for the heating operation and the MV absolute lower

                                                                        H>0, L<0        limit alarm functions only for the cooling operation.

                                                       SP H     L       |H| ≤ |L|  *10. This value is displayed only when a remote SP input is used. It functions in

                                                                                        both Local SP Mode and Remote SP Mode.

22
                                                                                                                                        E5EC/E5AC

Characteristics

                                   Thermocouple: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. *1

Indication accuracy                Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit

(at the ambient temperature of     Analog input: ±0.2% FS ±1 digit max.

23°C)                              CT input: ±5% FS ±1 digit max.

                                   Potentiometer input: ±5% FS ±1 digit max.

Transfer output accuracy           ±0.3% FS max.

Remote SP Input Type               ±0.2% FS ±1 digit max.

Influence of temperature *2        Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                                   Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *3

                                   Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

Influence of voltage *2            Analog input: ±1%FS ±1 digit max.

                                   CT input: ±5% FS ±1 digit max.

                                   Remote SP   input: ±1% FS ±1 digit max.

Input sampling period              50ms

Hysteresis                         Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or°F)

                                   Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)              Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

                                   Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in

Integral time (I)                  units of 0.1 s)

                                   Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s)*4

Derivative time (D)                0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling  Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                   Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling      0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling    0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                     0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                 0.0 to 100.0% (in units of 0.1%)

Alarm setting range                -1999 to 9999 (decimal point position depends on input type)

Influence of signal source resis-  Thermocouple: 0.1°C/Ω max. (100 Ω max.)

tance                              Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

Insulation resistance              20 MΩ min. (at 500 VDC)

Dielectric strength                2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction            10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

            Resistance             10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Shock       Malfunction            100 m/s2, 3 times each in X, Y, and Z directions

            Resistance             300 m/s2, 3 times each in X, Y, and Z directions

Weight                    E5EC     Controller: Approx. 210 g, Mounting Brackets: Approx. 4 g × 2

                          E5AC     Controller: Approx. 250 g, Mounting Brackets: Approx. 4 g × 2

Degree of protection               Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection                  Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                         CX-Thermo version 4.5 or higher

                                   E5EC/E5AC top panel:     An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port

Setup Tool port                                             on the computer.*5

                                   E5EC/E5AC front panel:   An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion

                                                            Cable are used together to connect to a USB port on the computer.*5

Standards   Approved standards     UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL), Korean Radio Waves Act (Act 10564)

            Conformed standards    EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *6

                                   EMI                                                                       EN61326

                                   Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                                   Noise Terminal Voltage:                                                   EN 55011 Group 1, class A

                                   EMS:                                                                      EN 61326

EMC                                ESD Immunity:                                                             EN 61000-4-2

                                   Electromagnetic Field Immunity:                                           EN 61000-4-3

                                   Burst Noise Immunity:                                                     EN 61000-4-4

                                   Conducted Disturbance Immunity:                                           EN 61000-4-6

                                   Surge Immunity:                                                           EN 61000-4-5

                                   Voltage Dip/Interrupting Immunity:                                        EN 61000-4-11

*1  The indication accuracy of K thermocouples in the -200 to 1300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at

    any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max.

    is not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples

    at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The

    indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.

*2  Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage

*3  K thermocouple at -100°C max.: ±10°C max.

*4  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5  External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.

*6  Refer to information on maritime standards in Shipping Standards on page 52 for compliance with Lloyd's Standards.

                                                                                                                                                                      23
E5EC/E5AC

USB-Serial Conversion Cable                                                                                                    When Digital Temperature Controllers are con-

                                                                                                                               nected, the parameters can be copied from the

    Applicable OS           Windows 2000, XP, Vista, or 7                                                                      Digital Temperature Controller that is set as the

    Applicable software     CX-Thermo version 4.5 or higher                                                                    master to the Digital Temperature Controllers that

                                                                                                                               are set as slaves.

    Applicable models       E5@C Series and E5CB Series                                                                        Number of connected Digital Temperature Con-

    USB interface standard  Conforms to USB Specification 2.0.                          Communications                         trollers: 32 max. (including master)

    DTE speed               38,400 bps                                                  between components*                    When Digital Temperature Controllers are con-

                                                                                                                               nected, set points and RUN/STOP commands

    Connector               Computer: USB (type A plug)                                                                        can be sent from the Digital Temperature Control-

    specifications          Digital Temperature Controller:                                                                    ler that is set as the master to the Digital Temper-

                            Special serial connector                                                                           ature Controllers that are set as slaves.

    Power supply            Bus power (Supplied from USB host controller.)*                                                    Slope and offsets can be set for the set point.

                                                                                                                               Number of connected Digital Temperature Con-

    Power supply voltage    5 VDC                                                                                              trollers: 32 max. (including master)

    Current consumption     450 mA max.                                                 MELSEC is a registered trademark of Mitsubishi Electric Corporation.

                            4.7±0.2 VDC                                                 * A Temperature Controller with version 1.1 or higher is required.

    Output voltage          (Supplied from USB-Serial Conversion Cable to

                            the Digital Temperature Controller.)                        Current Transformer (Order Separately)

                            250 mA max.                                                 Ratings

    Output current          (Supplied from USB-Serial Conversion Cable to

                            the Digital Temperature Controller.)

    Ambient operating                                                                   Dielectric strength                    1,000 VAC for 1 min

    temperature             0 to 55°C (with no condensation or icing)                   Vibration resistance                   50 Hz, 98 m/s2

    Ambient operating       10% to 80%                                                                                         E54-CT1: Approx. 11.5 g,

    humidity                                                                            Weight                                 E54-CT3: Approx. 50 g

    Storage temperature     -20 to 60°C (with no condensation or icing)                 Accessories                            Armatures (2)

    Storage humidity        10% to 80%                                                  (E54-CT3 only)                         Plugs (2)

    Altitude                2,000 m max.

    Weight                  Approx. 120 g                                               Heater Burnout Alarms and SSR Failure

Windows is a registered trademark of Microsoft Corporation in the                       Alarms

United States and or other countries.

*   Use a high-power port for the USB port.                                                                                    Models with detection for singlephase

Note: A driver must be installed on the computer. Refer to the                          CT input (for heater                   heaters: One input

          Instruction Manual included with the Cable for the installation               current detection)                     Models with detection for singlephase or

          procedure.                                                                                                           three-phase heaters: Two inputs

Communications Specifications                                                           Maximum heater                         50 A AC

                                                                                        current

    Transmission line       RS-485: Multidrop                                           Input current indica-                  ±5% FS ±1 digit max.

    connection method                                                                   tion accuracy

    Communications          RS-485 (two-wire, half duplex)                              Heater burnout

    Synchronization         Start-stop synchronization                                  alarm setting range                    0.1 to 49.9 A (in units of 0.1 A)

    method                                                                              *1                                     Minimum detection ON time: 100 ms *3

    Protocol                CompoWay/F, or Modbus                                       SSR failure alarm                      0.1 to 49.9 A (in units of 0.1 A)

    Baud rate               19200, 38400, or 57600 bps                                  setting range *2                       Minimum detection OFF time: 100 ms *4

    Transmission            ASCII                                                       *1.                      For heater burnout alarms, the heater current will be measured when the

    code

    Data bit length*        7 or 8 bits                                                                          control output is ON, and the output will turn ON if the heater current is

                                                                                                                 lower than the set value (i.e., heater burnout detection current value).

    Stop bit length*        1 or 2 bits                                                 *2.                      For SSR failure alarms, the heater current will be measured when the

                            Vertical parity (none, even, odd)                                                    control output is OFF, and the output will turn ON if the heater current is

    Error detection         Block check character (BCC) with                                                     higher than the set value (i.e., SSR failure detection current value).

                            CompoWay/F or CRC-16 Modbus                                 *3.                      The value is 30 ms for a control period of 0.1 s or 0.2 s.

    Flow control            None                                                        *4.                      The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Interface               RS-485

    Retry function          None                                                        Electrical Life Expectancy Curve for

    Communications buffer   217 bytes                                                   Relays (Reference Values)

    Communications          0 to 99 ms

    response wait time      Default: 20 ms                                              Life (× 104 operations)  500

*   The baud rate, data bit length, stop bit length, and vertical parity  can  be  in-                           300

    dividually set using the Communications Setting Level.

Communications Functions                                                                                         100           E5EC/E5AC

                                                                                                                               250 VAC, 30 VDC

                                                                                                                               (resistive load)

                            You can use the memory in the PLC to read and                                        50            cosφ = 1

                            write E5@C parameters, start and stop operation,                                     30

                            etc. The E5@C automatically performs communi-

                            cations with PLCs. No communications program-

                            ming is required.                                                                    10

    Programless             Number of connected Temperature Controllers:

    communications*         32 max.                                                                              5

                            Applicable PLCs                                                                      3

                            OMRON PLCs

                                  SYSMAC CS Series, CJ Series, or CP Se-

                                  ries                                                                           1

                            Mitsubishi Electric PLCs                                                                  0  1  2  3         4       5  6

                                  MELSEC Q Series or L Series                                                                     Switching current (A)

24
                                                                                                                                                                                                               E5EC/E5AC

External Connections

E5EC/E5AC

                       E5EC- @ @                    4     @     5     M - @@@                    E5AC- @ @             4         @    5     M - @@@

                                          (1)      (2) (3) (4) (5)             (6)                             (1)     (2) (3) (4) (5)                     (6)               The E5EC is set for a K-type thermocouple (input

                                                                ↑                                                                     ↑                                      type = 5) by default. An input error (s.err) will occur

                                                       Terminal type                                                      Terminal type                                      if the input type setting does not agree with the

                                                                                                                                                                             temperature sensor. Check the input type.

   Control output 1                       Control output 2                     Auxiliary outputs 1 to 4                (6) Options

Relay output                          Relay output                             Relay output                                      004                        005                   009                                  010

250 VAC, 5 A                          250 VAC, 5 A                             Models with 4 auxiliary                           Communications             4 event  inputs       Communications, 2 event              4 event inputs

(resistive load)                      (resistive load)                         outputs: 250 VAC, 2 A                             and 2 event inputs                               inputs, and 2 CT inputs              and 1 CT input

Voltage output                        Voltage output                           (resistive load)                                     B(+)       13                        13                 B(+)     13

(for driving SSR)                     (for driving SSR)                                                                          RS-485                                                RS-485                                    13

12 VDC, 40 mA                         12 VDC, 21 mA                                                                                   A(-)     14               EV3      14                 A(-)     14                EV3       14

When There Is a                       Linear current output                                                                                    15           EV4          15                          15                EV4       15

Control Output 2:                     0 to 20 mA DC                                                                                            16                        16                          16                          16

21 mA                                 4 to 20 mA DC                                                                                            17                        17                          17                          17

Linear current output                 Load: 500 Ω max.                                                                                EV1      18               EV1      18                 EV1      18                EV1       18

0 to 20 mA DC                                                                                                                    EV2                        EV2                        EV2                             EV2

4 to 20 mA DC                                                                                                                                  19                        19                          19                CT1       19

Load: 500 Ω max.                                                                                                                               20                        20            CT1           20                          20

                                                                                                                                                                                            COM

                                                                                                                                               21                        21            CT2           21                          21

(1) Control output

    RX                        QX                          CX                                                                                       011

Models with            Models with 1                Models with 1                                                                                  6 event Inputs, 1 CT input,

1 Relay Output         Voltage Output               Linear Current Output                                                                          transfer output, and remote SP input

                       (for Driving SSR)

    3           OUT1       3          +   OUT1            3        +  OUT1          (3) Input Power Supply                                                                                  13

    4           R          4          -   Q                        -  C                                                                                                                     14

                                                          4                         100 to 240 VAC         24 VAC/DC                                                              EV3

    5                      5                              5                                                                                                                  EV4            15

                                                                                                    1                  1                                             28                     16

    6                      6                              6                                                            2                                             29                     17

                                                                                                    2                                                           EV5               EV1

   QQ                                     QR                                                                   (no polarity)                                EV6      30      EV2            18

Models with 2 Voltage         Models with Voltage Output (for                                                                                               +        31                     19

Outputs (for Driving SSR)     Driving SSR) and Relay Output                                                                                        Transfer V    +   32           CT1       20

                OUT1                            OUT1                                                                                               output        I

    3        +  Q                 3          +  Q                                   1               25     13                                               -        33                     21

    4        -                    4          -                                      2               26     14                                               +    +   34

    5                             5                                                 3               27     15                                      Remote V      mA  35

             +  Q                               R                                                                                                  SP       -        36

    6        -  OUT2              6             OUT2                                4               28     16

RR                 PR                     CC                                        5               29     17                                      013                                          014

Models with 2      Models with 2          Models with 2                             6               30     18                                      6 event Inputs, transfer                     Communications, 4 event Inputs,

Relay Outputs      Position-proportional  Linear Current                            7               31     19                                      output, and remote SP input                  transfer output, and remote SP input

                   Relay Output   Open    Outputs                                   8               32     20                                                                                                               B(+)

3            OUT1   3                        3               OUT1                                                                                                                      13                                   RS-485     13

             R                    R                    +     C                      9               33     21                                                                          14                                              14
                                                       -
4                   4                        4                                      10              34     22                                                                EV3                                            A(-)
                                                                                                                                                                                       15                                              15
                                                                                                                                                                             EV4
5                   5                        5         +                            11              35     23                                                    28                                                28                  16
                                                             C                                                                                                                         16
             R                    R                    -
6                   6                        6                                      12              36     24                                                                                                      29
             OUT2                 Close                      OUT2                                                                                                29                    17                   EV5                        17
                                                                                                                                                           EV5               EV1                                            EV1
CQ                                                                                                                                                                                                                 30                  18
                                                                                                                                                       EV6       30          EV2       18            EV6                    EV2

Models with 2 Outputs: Linear Current Output                                                                                                            +        31                    19                +         31                  19

and Voltage (for Driving SSR)                                                                                                               Transfer V      +                               Transfer        V  +   32                  20

                                                                                                                                            output          I    32                    20   output             I

    3        +  OUT1             (2)  Auxiliary Outputs                                          Potentiometer Input                                    -        33                    21                -         33                  21

             -  C                                                                                                                                       +        34                                      +         34

    4                                     Auxiliary outputs        1, 2, 3, 4                           O      19                              Remote V     +                               Remote V           +

    5                                           7                                                              20                                           mA   35                         SP                 mA  35

             +  Q                                   Auxiliary      output 4                             W                                      SP       -        36                                      -         36

    6        -  OUT2                            8                                                       C      21

                                                9   Auxiliary      output 3

                                                                                                                                                           Note:     1.  The application of the terminals depends on

                                                10  Auxiliary      output 2                                                                                              the model.

                                                11                                  (5) Sensor (Temperature/Analog) Input                                            2.  Do not wire the terminals that are shown with

                                                12  Auxiliary      output 1                         TC             Pt            I                 V                     a gray background.

                                                                                                    22     A       22         +  22                22                3.  When complying with EMC standards, the

                                                                                                 -  23         B   23  mA        23            -   23                    cable that connects the sensor must be 30 m

                                                                                                    24         B 24           -  24         V      24                    or less. If the cable length exceeds 30 m,

                                                                                                 +                                             +                         compliance with EMC standards will not be

                                                                                                                                                                         possible.

                                                                                                                                                                     4.  Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

Models with 4 Auxiliary Outputs

                       Sensor input, CT inputs, potentiometer input, and remote SP input

                                          Communications and event inputs

                                          Voltage output (for driving SSR),

        Power                         linear current output, and transfer output

        Supply

                                                          Relay output

                                                   Auxiliary outputs 1, 2

                                                   Auxiliary outputs 3, 4

                       : Reinforced insulation

                       : Functional isolation

Note:   Auxiliary   outputs 1 to 2 and 3 to 4 are not insulated.

                                                                                                                                                                                                                                           25
E5EC/E5AC

Nomenclature

E5EC

                                 Front panel

                                                                                No. 1 display

                                                                                PV or specified parameter                                             Top View of  E5EC

      Temperature unit

      Operation indicators                                                      No. 2 display

                                                                                SP or specified parameter value

                                                                                No. 3 display                                                                               Top-panel

    Front-panel Setup Tool port                                                 Manipulated value or other value                                                            Setup

                                                                                MUansieputhlaeteUd vaDlueKoeryosthtoersveatlue                                              Tool port

                                                                                the parameter.

                                                                                Use S Key to change the digit                   (default  setting).

                                                                                Use the M Key to change to another parameter.

    Press O Key once to go to Adjustment Level.

    Press O Key for at least 3 seconds to go to Initial Setting  Level.

E5AC

                                 Front Panel

                                                                                                                                                      Top          View of  E5AC

    Temperature unit                                                            No. 1 display

    Operation indicators                                                        PV or specified parameter

                                                                                No. 2 display

                                                                                SP or specified parameter value

    Front-panel Setup Tool port                                                 No. 3 display

                                                                                Manipulated value or other value

                                                                                Press the U or D Key to set                     the       parameter.                              Top-panel

                                                                                                                                                                                  Setup

                                                                                                                                                                                  Tool port

                                                                                Press the S Key to change the digit (default setting).

    Press the O Key once to go to the Adjustment Level.                         Press the M Key to change to another parameter.

    Press the O Key for at least 3 seconds to go to the Initial Setting Level.

26
                                                                                                                                                          E5EC/E5AC

Dimensions                                                                                                                                                 (Unit: mm)

Controllers

E5EC

                                                                         4            (64)

                                                       48                1            60                     44

                                                                                                                                    The Setup Tool port is on the top of the Tem-

                                                                                                                                    perature Controller.

                                                                                                                                    It is used to connect the Temperature Con-

                                                                                                                                    troller to the computer to use the Setup Tool.

                                                                                                                                    The E58-CIFQ2 USB-Serial Conversion

                                                                                                                                    Cable is required to make the connection.

                                          96                                                            110                     91  Refer to the instructions that are provided

                                                                                                                                    with the USB-Serial Conversion Cable for the

                                                                                                                                    connection procedure.

                                                                                                                                    Note:  Do not leave the USB-Serial

                                                                                                                                           Conversion Cable connected when

                                                                                                                                           you use the Temperature Controller.

                                                       Waterproof

                                                       Packing (Accessory)            Mounting Adapter

                                                                                      (Accessory)

             Mounted Separately                    Group Mounted *

                                                   (48 × number of units − 2.5)+10.0                    *    Selections for Control Outputs 1 and 2: QQ, QR, RR, CC, PR, or CQ

                       45+0.06                                                                               If you also specify 011, 013, or 014 for the option selection and use

                                                                                                             group mounting, the ambient temperature must be 45°C or less.

                                                                                                             If the ambient temperature is 55°C, maintain the following mounting

                                                                                                             spaces between Controllers.

                                                                         92+00.8

                                                                                                                                60 min.

                                                                                                                       45-00.6

             120 min.                              Group mounting does not

                                                   allow waterproofing.

                                                                                                                                           92+00.8

                                          92-00.8

                                                                                                             120 min.

      •  Recommended panel thickness is 1 to 8 mm.

      •  Group mounting is not possible in the vertical direction. (Maintain the

         specified mounting space between Controllers.)

      •  To mount the Controller so that it is waterproof, insert the waterproof

         packing onto the Controller.

      •  When two or more Controllers are mounted, make sure that the

         surrounding temperature does not exceed the allowable operating

         temperature specified in the specifications.

      •  To attach the USB-Serial Conversion Cable to the control panel, use a

         panel thickness of 1 to 2.5 mm.

                                                                                                                                                                                    27
E5EC/E5AC

E5AC                                                                                                        (64)

                                                                                                   4        60

                                                                    96 x 96                              1                                91 x 91

                                                                                                                     110                               91

                                                                              Waterproof

                                                                              Packing (Accessory)  Mounting Adapter

                                                                                                   (Accessory)

                                           The Setup Tool port is on the top of the Temperature Controller.

                                           It is used to connect the Temperature Controller to the computer to use the Setup Tool.

                                           The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.

                                           Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.

                                           Note: Do not leave the USB-Serial Conversion Cable connected when you use the Temperature Controller.

              Mounted Separately           Group Mounted *

                                           (96 × number of units − 3.5)+10.0                          •  Recommended panel thickness is 1 to 8 mm.

              92+00.8

                                                                                                      •  Group mounting is not possible in the vertical direction. (Maintain the

                                                                                                         specified mounting space between Controllers.)

                                                                                                      •  To mount the Controller so that it is waterproof, insert the waterproof

                                                                                                         packing onto the Controller.

                                                                              92+00.8                 •  When two or more Controllers are mounted, make sure that the

                                                                                                         surrounding temperature does not exceed the allowable operating

                                                                                                         temperature specified in the specifications.

                                                                                                      •  To attach the USB-Serial Conversion Cable to the control panel, use a

                                           Group mounting does not                                       panel thickness of 1 to 2.5 mm.

    120 min.                               allow waterproofing.

                                  92+00.8

28
                                                                                                                                 E5EC/E5AC

Accessories (Order Separately)

● USB-Serial Conversion Cable                                                                      (2,110)

E58-CIFQ2                                                                                                    (13)                              (5) (15)

                                                250                                      (87)                             1,740

                                                                              LED(RD)                              (250)

                                         USB    connector (type A plug)

                                                                                                      LED(PWR)                                 Serial connector

                                                                                                      LED(SD)

● Conversion Cable

E58-CIFQ2-E

           Conversion Cable                     Connecting to            the  E58-CIFQ2 USB-Serial Conversion Cable

                                                                                                      (2110)

                         (1510)                                 250                                                263                 1510

                                                                              E58-CIFQ2  (Order Separately)                      Conversion Cable

Note: Always use this product together with     the E58-CIFQ2.

● Terminal Covers                               ● Waterproof Packing

E53-COV24 (Three Covers provided.)              Y92S-P9 (for DIN 48 × 96)

                                 2  3.8

                                                                                         The Waterproof Packing is provided with the Temperature

                                                                                         Controller.

                         10                                                              The degree of protection when the Waterproof Packing is used

                                                                                         is IP66.

                                                                                         Also, keep the Port Cover on the front-panel Setup Tool port

                                                                                         of the E5EC/E5AC securely closed.

                                                                                         To maintain an IP66 degree of protection, the Waterproof

                                                                                         Packing and the Port Cover for the front-panel Setup Tool port

                     91                                                                  must be periodically replaced because they may deteriorate,

                                                                                         shrink, or harden depending on the operating environment.

                                                                                         The replacement period will vary with the operating

                                                                                         environment.

                                                Y92S-P10 (for DIN 96 × 96)               Check the required period in the actual application.

                                                                                         Use 3 years or sooner as a guideline.

                                                                                         If a waterproof structure is not required, then the Waterproof

                                                                                         Packing does not need to be installed.

● Setup  Tool  Port  Cover   for    top  panel                                ● Mounting Adapter

Y92S-P7                                                                       Y92F-51 (for DIN 48 × 96)

                                         Order this Port Cover                                                            One pair is provided with the

                                         separately if the Port Cover on                                                  Controller.

                                         the front-panel Setup Tool port                                                  Order this Adapter

                                         is lost or damaged. The                                                          separately if it becomes lost

                                         Waterproof Packing must be                                                       or damaged.

                                         periodically replaced because

                                         it may deteriorate, shrink, or

                                         harden depending on the

                                         operating environment.

                                                                                                                                                                 29
E5EC/E5AC

● Watertight Cover                                                                       ● Watertight Cover

Y92A-49N (48 × 96)                                                                       Y92A-96N (96 × 96)

                                                      21.9  (2)                                                                                                                                       21.9        (2)

                    131.7                                                                131.7

                                 67.6                 29.4                                                                      115.6                                                                 29.4

● Current Transformers

E54-CT1                                                                                         Thru-current (Io) vs. Output Voltage (Eo)

                                                  21                       2.8                  (Reference Values)

                                                  15        5.8 dia.

                                                                                                E54-CT1

                                                                                 7.5            Maximum continuous heater current:                                                                    50 A (50/60 Hz)

                                                                                                Number of windings:                                                                                   400±2

                                       25      3                                                Winding resistance:                                                                                   18±2 Ω

                                                            10.5                                                                Output voltage (Eo) V (r.m.s.)  100V          Frequency: 50 Hz

                                                  40                                                                                                                   10                       ∞                           Distortion

                                                            Two, 3.5 dia.                                                                                                                   1kΩ                             factor

                                                                                                                                                                                                                            10%

                                                                                                                                                                       1

                                           10                                                                                                                                                                           3%

                                                                                                                                                                                                                    1%

                                                  30                                                                                                            100mV

                                                                                                                                                                       10                                100Ω

E54-CT3

                                                                      2.36 dia.                                                                                        1                                 RL=10Ω

                                                  30

                                                            12 dia.

                                                                                      9                                                                         100μV

                                                                                                                                                                       10

                                                                                                                                                                           1      10     100mA        1         10          100  1,000A

                                       40  × 40                                                                                                                                                          Thru-current (Io) A (r.m.s.)

                                                                                                Thru-current (Io) vs. Output Voltage (Eo)

                                                                                                (Reference Values)

                                                            Two, M3 (depth: 4)                  E54-CT3

                                                                                                Maximum continuous heater current:                                                                    120 A (50/60 Hz)

                                           15                                                   (Maximum continuous heater current for an OMRON Digital

                                                                                                Temperature Controller is 50 A.)

                                                  30                                            Number of windings:                                                                                   400±2

                                                                                                Winding resistance:                                                                                   8±0.8 Ω

E54-CT3 Accessories                                                                             Output voltage (Eo) V (r.m.s.)  100V

    • Armature                                    Connection Example                                                                                                   Frequency: 50 Hz

                                                                                                                                                                                         ∞                                  Distortion

                                                                      Armature                                                                                  10                    1kΩ                                   factor

    Approx. 3 dia.                                    Plug                                                                                                                            500Ω                                  10%

                                                                                                                                                                                                                            3%

                                                                                                                                                                1                                                      1%

                                                                                Lead

                                                                                                                                100mV

                                                                                                                                                                                                            100Ω

                                 18                                                                                                                             10                                       50Ω

    • Plug                                                                                                                                                                                               RL=10Ω

                                                                                                                                                                1

    Approx. 6 dia.                                                                                                              100μV

                           (22)                                                                                                                                 10

                                                                                                                                                                    1         10  100mA            1        10         100  1,000A

                                                                                                                                                                                                      Thru-current (Io) A (r.m.s.)

30
MEMO

      31
    Digital Temperature Controller

    E5DC                       (22.5 mm Wide, and DIN Track-mounting Type)

The E5DC Mounts to DIN Track and Is Ideal

for Connections to HMIs and PLCs.

It provides the Same Easy Operation and

Advanced Performance as the Rest of the

E5@C Series.

    • A slim body at 85 × 22.5 mm (D × W) that fits into narrow control

    panels and mounts to DIN Track.

    • Removable terminal block for easy replacement to simplify maintenance.

    • High-speed sampling at 50 ms for applications with high-speed

    temperature increases.

    • Easy connections to a PLC with programless communications.

    • Set up the Controller without wiring the power supply by connecting

    to the computer with a Communications Conversion Cable (sold separately).           22.5 mm Wide, and

    Setup is easy with the CX-Thermo (sold separately).                                 DIN Track-mounting Type

    • Models are available with up to 2 auxiliary outputs and 1 event input to                     E5DC

    complete basic functions.                                                   Refer to your OMRON website for the most recent

    • A white PV display (height: 8.5 mm) is easy to read when setting up,      information on applicable safety standards.

    checking alarms, and making settings in a control panel.                        Refer to Safety Precautions on page 50.

Main  I/O Functions

      Sensor Input                                                     E5DC

      Universal input

      • Thermocouple

      • Pt                                                                      Dual displays: PV/SV           4-digit  displays

      • Analog current/voltage

            Indication Accuracy                                                 Control Output 1

            • Thermocouple input:                                               • Relay output

            ±0.3% of PV                                                         • Voltage output (for driving  SSR)

            • Pt input: ±0.2% of PV                                             • Linear current output

            • Analog input:

            ±0.2% of FS

                                                                                Auxiliary Outputs

            Sampling Period                                                     • None

            • 50 ms                                                             •2

      Event Inputs

      • None                         • PF (shift) Key

      •1                             • Temperature status display

      Serial Communications          • Simple programming

      • None                         • Independent heating and

                                     cooling PID control

      • RS-485                       • Changed parameter display

                                     • Display brightness setting

    This datasheet is provided as a guideline for selecting products.

    Be sure to refer to the following manuals for application precautions and other information required for operation before attempting

    to use the product.

    E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)

    E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)

32
                                                                                                                                                E5DC

Model Number Legend and Standard Models

Model Number Legend

E5DC-@@            @ @ @ @ -@@@ (Example: E5DC-RX0ASM-015)
        −−         − − − − −−−
           A       BC      DE           F

                A            B          C           D            E           F

Model      Control      No. of          Power       Terminal     Input                                         Meaning

           output 1  auxiliary       supply         type         type        Options

                     outputs         voltage

E5DC                                                                                             22.5 mm wide and mounts to DIN Track

                                                                                                         Control output 1

           RX                                                                                                  Relay output

           QX                                                                                            Voltage output

                                                                                                         (for driving SSR)

           CX                                                                                            Linear current output *5

                     0                                                                                         None

                     2                                                                                   2 (one common)

                                     A                                                                   100 to 240 VAC

                                     D                                                                         24 VAC/DC

                                               S                                                         Screw terminals

                                                              M                                          Universal input

                                                                                      HB  alarm  and HS alarm  Communications          Event input

                                                                        *1   000                 ---                           ---              ---

                                                                        *2   002                      1                  RS-485                 ---

                                                                        *3   015                 ---                     RS-485                 ---

                                                                        *4   016                 ---                           ---              1

                                                                        *2   017                      1                        ---              1

*1  Option 000 can be selected only if two auxiliary outputs are selected.

*2  Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.

*3  Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.

*4  Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.

*5  The control output cannot be used as a transfer output.

List of Models

                                                                 Options                                 Model                         Model

Control output     No. of auxiliary     HB alarm and HS                                                  Power supply voltage        Power supply voltage

                     outputs               alarm              No. of event inputs     Communications

                                                                                                         100 to 240 VAC              24 VAC/DC

                        ---                    ---                                    RS-485             E5DC-RX0ASM-015             E5DC-RX0DSM-015

Relay output                                                            ---               ---            E5DC-RX2ASM-000             E5DC-RX2DSM-000

                        2            Detection for single-                            RS-485             E5DC-RX2ASM-002             E5DC-RX2DSM-002

                                     phase heater                       1                 ---            E5DC-RX2ASM-017             E5DC-RX2DSM-017

                        ---                    ---                                    RS-485             E5DC-QX0ASM-015             E5DC-QX0DSM-015

Voltage output                                                          ---               ---            E5DC-QX2ASM-000             E5DC-QX2DSM-000

(for driving SSR)       2            Detection for single-                            RS-485             E5DC-QX2ASM-002             E5DC-QX2DSM-002

                                     phase heater                       1                 ---            E5DC-QX2ASM-017             E5DC-QX2DSM-017

                        ---                                                           RS-485             E5DC-CX0ASM-015             E5DC-CX0DSM-015

Linear current                                 ---                      ---               ---            E5DC-CX2ASM-000             E5DC-CX2DSM-000

output                  2                                                             RS-485             E5DC-CX2ASM-015             E5DC-CX2DSM-015

                                                                        1                 ---            E5DC-CX2ASM-016             E5DC-CX2DSM-016

Note: These products are sold as a set with a terminal block (i.e., Terminal Unit).

Heating and Cooling Control

●Using Heating and Cooling Control

A Control Output Assignment

An auxiliary output is used as the cooling control output.

B Control

If PID control is used, you can set PID control separately for heating and cooling.

This allows you to handle control systems with different heating and cooling response characteristics.

                                                                                                                                                           33
E5DC

Optional Products (Order Separately)

USB-Serial Conversion Cable                                        End Plate

             Model                                                              Model

            E58-CIFQ2                                                           PFP-M

Conversion Cable                                                   Spacer

             Model                                                              Model

            E58-CIFQ2-E                                                         PFP-S

Note: Always use this product together with the E58-CIFQ2.

    This Cable is used to connect to the front-panel Setup   Tool  DIN Tracks

    port.                                                                       Model

Current Transformers (CTs)                                                      PFP-100N

    Hole diameter            Model                                              PFP-50N

    5.8 mm                  E54-CT1

    12.0 mm                 E54-CT3                                Unit Labels

                                                                                Model

Mounting Adapters                                                               Y92S-L2

             Model

            Y92F-53

Short Bars

             Model

            Y92S-P11

CX-Thermo Support Software

             Model

            EST2-2C-MV4

Note: CX-Thermo version 4.6 or higher is required for the E5DC.

    For the system requirements for the CX-Thermo, refer to

    information on the EST2-2C-MV4 on the OMRON website

    (www.ia.omron.com).

34
                                                                                                                                      E5DC

Specifications

Ratings

Power supply voltage               A in model number: 100 to 240 VAC, 50/60 Hz

                                   D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range            85% to 110% of rated supply voltage

Power consumption                  4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC

                                   Temperature input

                                   Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II

                                   Platinum resistance thermometer: Pt100 or JPt100

Sensor input                       Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C

                                   Analog input

                                   Current input: 4 to 20 mA or 0 to 20 mA

                                   Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Input impedance                    Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/

                                   THB.)

Control method                     ON/OFF control or 2-PID control (with auto-tuning)

           Relay output            SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5

Control                            V, 10 mA

output     Voltage output          Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit

           (for driving SSR)

           Linear current output   4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000

Auxiliary  Number of outputs       2 (depends on model)

outputs    Output specifications   SPST-NO relay outputs: 250 VAC, 2 A (resistive load),

                                   Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V

           Number of inputs        1 (depends on model)

Event      External contact input  Contact input ON: 1 kΩ max., OFF: 100 kΩ min.

inputs     specifications          Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.

                                   Current flow: approx. 7 mA per contact

Setting method                     Digital setting using front panel keys

Indication method                  11-segment digital displays and individual indicators

                                   Character height: PV: 8.5 mm, SV: 8.0 mm

Multi SP                           Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or

                                   serial communications.*

Bank switching                     None

                                   Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burn-

                                   out (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self

Other functions                    tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change

                                   rate limit, simple calculations, temperature status display, simple programming, moving average of input

                                   value, and display brightness setting

Ambient operating temperature      −10 to 55°C (with no condensation or icing), for 3-year warranty: −10 to 50°C (with no condensation or

                                   icing)

Ambient operating humidity         25% to 85%

Storage temperature                −25 to 65°C (with no condensation or icing)

* Only two set points are selectable for event inputs.

                                                                                                                                                35
E5DC

Input Ranges

●Thermocouple/Platinum Resistance Thermometer (Universal inputs)

    Input type                          Platinum resistance                                                                 Thermocouple                                                Infrared temperature

                                        thermometer                                                                                                                                            sensor

    Name                                Pt100            JPt100              K               J               T         E      L           U         N     R     S     B     W     PLII  10 to  60 to  115 to  140 to

                                                                                                                                                                                        70°C   120°C  165°C   260°C

                            2300                                                                                                                                            2300

                            1800                                                                                                                                      1800

                            1700                                                                                                                          1700  1700

                            1600

                            1500

                            1400                                       1300                                                                         1300                          1300

    Temperature range (°C)  1300

                            1200

                            1100

                            1000  850                                                  850                                    850

                            900

                            800

                            700                                                                                        600

                            600         500.0          500.0                    500.0

                            500                                                                 400.0  400      400.0               400      400.0

                            400                                                                                                                                                                               260

                            300                                                                                                                                                                120    165

                            200                 100.0          100.0                                                                                                                    90

                            100                                                                                                                                       100

                            -100                0.0            0.0                                                                                        0     0           0     0     0      0      0       0

                            -200                                                -20.0  -100     -20.0                         -100

                                  -200  -199.9         -199.9          -200                            -200  -199.9    -200         -200  -199.9    -200

    Setting                       0     1       2        3     4       5        6      7         8     9        10     11     12    13       14     15    16    17    18    19    20    21     22     23      24

    range

                            Shaded settings are the default settings.

The applicable standards for the input types are as follows:

K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 60584-1                                            JPt100: JIS C 1604-1989, JIS C 1606-1989

L: Fe-CuNi, DIN 43710-1985                                                                      Pt100: JIS C 1604-1997, IEC 60751

U: Cu-CuNi, DIN 43710-1985                                                                      PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)

W: W5Re/W26Re, ASTM E988-1990

●Analog input

                            Input type                   Current                                       Voltage

    Input specification                         4 to 20 mA     0 to 20 mA              1 to 5 V        0 to 5 V        0 to 10 V

                                                Usable in the following ranges by scaling:

    Setting range                               -1999 to 9999, -199.9 to 999.9,

                                                -19.99 to 99.99 or -1.999 to 9.999

    Setting number                                   25                26              27              28                 29

36
                                                                                                                                                 E5DC

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.)

Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not

    displayed.

    To use alarm 1, set the output assignment to alarm 1.

Set                                                Alarm output operation

value           Alarm type             When alarm value X           When alarm value X                             Description of function

                                                is positive              is negative

0          Alarm function OFF                                Output OFF                       No alarm

                                                                                              Set the upward deviation in the set point for the alarm upper

                                           ON      L     H                                    limit (H) and the lower deviation in the set point for the alarm

1          Upper- and lower-limit *1       OFF               PV     *2                        lower limit (L). The alarm is ON when the PV is outside this

                                                   SP

                                                                                              deviation range.

2                                                        X                    X               Set the upward deviation in the set point by setting the alarm

           Upper-limit                     ON                       ON                        value (X). The alarm is ON when the PV is higher than the

(default)                                  OFF     SP        PV     OFF       SP          PV

                                                                                              SP by the deviation or more.

                                           ON      X                ON              X         Set the downward deviation in the set point by setting the

3          Lower-limit                     OFF               PV     OFF                   PV  alarm value (X). The alarm is ON when the PV is lower than

                                                   SP                         SP              the SP by the deviation or more.

                                                                                              Set the upward deviation in the set point for the alarm upper

           Upper- and lower-limit          ON      L     H                                    limit (H) and the lower deviation in the set point for the alarm

4          range *1                        OFF               PV     *3                        lower limit (L). The alarm is ON when the PV is inside this de-

                                                   SP

                                                                                              viation range.

           Upper- and lower-limit          ON      L     H                                    A standby sequence is added to the upper- and lower-limit

5          with standby sequence *1        OFF               PV     *4                        alarm (1). *6

                                       *5          SP

           Upper-limit with standby        ON            X          ON        X

6          sequence                        OFF               PV     OFF                   PV  A standby sequence is added to the upper-limit alarm (2). *6

                                                   SP                         SP

           Lower-limit with standby        ON      X                ON              X

7          sequence                        OFF               PV     OFF                   PV  A standby sequence is added to the lower-limit alarm (3). *6

                                                   SP                         SP

           Absolute-value upper-lim-       ON         X             ON           X            The alarm will turn ON if the process value is larger than the

8          it                              OFF               PV     OFF                   PV  alarm value (X) regardless of the set point.

                                                0                                      0

                                           ON         X             ON           X            The alarm will turn ON if the process value is smaller than the

9          Absolute-value lower-limit      OFF               PV     OFF                   PV  alarm value (X) regardless of the set point.

                                                0                                      0

           Absolute-value upper-lim-       ON         X             ON           X            A standby sequence is added to the absolute-value upper-

10         it with standby sequence        OFF               PV     OFF                   PV  limit alarm (8). *6

                                                0                                      0

           Absolute-value lower-limit      ON         X             ON           X            A standby sequence is added to the absolute-value lower-

11         with standby sequence           OFF               PV     OFF                   PV  limit alarm (9). *6

                                                0                                      0

12         LBA (alarm 1 type only)                               -                            *7

13         PV change rate alarm                                  -                            *8

           SP absolute-value               ON         X             ON           X            This alarm type turns ON the alarm when the set point (SP)

14         upper-limit alarm               OFF               SP     OFF                   SP  is higher than the alarm value (X).

                                                0                                      0

           SP absolute-value               ON         X             ON           X            This alarm type turns ON the alarm when the set point (SP)

15         lower-limit alarm               OFF               SP     OFF                   SP  is lower than the alarm value (X).

                                                0                                      0

                                       Standard Control             Standard  Control

                                           ON         X             ON           X

                                           OFF  0            MV     OFF                   MV

           MV absolute-value                                                           0      This alarm type turns ON the alarm when the manipulated

16         upper-limit alarm *9        Heating/Cooling              Heating/Cooling           variable (MV) is higher than the alarm value (X).

                                       Control (Heating MV)         Control (Heating MV)

                                           ON         X

                                           OFF  0            MV     Always ON

                                       Standard Control             Standard  Control

                                           ON         X             ON           X

                                           OFF  0            MV     OFF                0  MV

17         MV absolute-value           Heating/Cooling                                        This alarm type turns ON the alarm when the manipulated

           lower-limit alarm *9        Control (Cooling MV)         Heating/Cooling           variable (MV) is lower than the alarm value (X).

                                                                    Control (Cooling MV)

                                           ON         X

                                           OFF  0            MV     Always ON

                                                                                                                                                                37
E5DC

*1  With set values 1, 4, and 5, the upper- and lower-limit values can      *4  Set value: 5, Upper- and lower-limit with standby sequence

    be set independently for each alarm type, and are expressed as              For Upper- and Lower-Limit Alarm Described Above at *2

    “L” and “H.”                                                                •  In cases 1 and 2 above, the alarm is always OFF if the upper-

*2  Set value: 1, Upper- and lower-limit alarm                                     and lower-limit hysteresis overlaps.

    Case 1             Case 2     Case 3 (Always OFF)                           •  In case 3, the alarm is always OFF.

                                                                 H<0, L<0   *5  Set value: 5, Upper- and lower-limit alarm with standby sequence

            L  H  SP   SP L    H     H               SP    L                    The alarm is always OFF if upper- and lower-limit hysteresis

            H<0, L>0   H>0, L<0                                  H<0, L>0       overlaps.

            |H| < |L|  |H| > |L|  H             L SP             |H| ≥ |L|  *6  Refer to the E5@C Digital Temperature Controllers User’s Manual

                                                                 H>0, L<0       (Cat. No. H174) for information on the operation of the standby

                                                     SP H     L  |H| ≤ |L|      sequence.

*3  Set value: 4,      Upper- and lower-limit range                         *7  Refer to the E5@C Digital Temperature Controllers User’s Manual

    Case 1             Case 2     Case 3 (Always ON)                            (Cat. No. H174) for information on the LBA.

                                                                 H<0, L<0   *8  Refer to the E5@C Digital Temperature Controllers User’s Manual

    L          H  SP   SP L    H     H               SP    L                    (Cat. No. H174) for information on the PV change rate alarm.

    H<0, L>0           H>0, L<0                                  H<0, L>0   *9  When heating/cooling control is performed, the MV absolute-

    |H| < |L|          |H| > |L|  H             L SP             |H| ≥ |L|      value upper-limit alarm functions only for the heating operation

                                                                 H>0, L<0       and the MV absolute-value lower-limit alarm functions only for the

                                                     SP H     L  |H| ≤ |L|      cooling operation.

38
                                                                                                                                        E5DC

Characteristics

Indication accuracy                 Thermocouple:*1  (±0.3 % of PV or ±1°C, whichever is greater) ±1 digit max.

(when mounted individually, ambi-   Platinum resistance thermometer: (±0.2 % of PV or ±0.8°C, whichever is greater) ±1 digit max.

ent temperature of 23°C)            Analog input:    ±0.2% FS ±1 digit max.

                                    CT input:        ±5% FS ±1 digit max.

Influence of temperature       *2   Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                                    Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max.             *3

Influence of voltage   *2           Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

                                    Analog input: ±1% FS ±1 digit max.

                                    CT input: ±5% FS ±1 digit max.

Installation influence (E5DC only)  R, S, B, W, or PLII thermocouple: (±1% of PV or ±10°C, whichever is greater) ±1 digit max.

                                    Other thermocouple: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *3

Input sampling period               50 ms

Hysteresis                          Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                    Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)               Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)                   0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D)                 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Proportional band (P) for cooling   Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)

                                    Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I) for cooling       0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Derivative time (D) for cooling     0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4

Control period                      0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)

Manual reset value                  0.0% to 100.0% (in units of 0.1%)

Alarm setting range                 −1,999 to 9,999 (decimal point position depends on input type)

Influence of signal source resis-   Thermocouple: 0.1°C/Ω max. (100 Ω max.), Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)

tance

Insulation resistance               20 MΩ min. (at 500 VDC)

Dielectric strength                 2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration   Malfunction             10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions

            Resistance              10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions

Shock       Malfunction             100 m/s2, 3 times each in X, Y, and Z directions

            Resistance              300 m/s2, 3 times each in X, Y, and Z directions

Weight                              Controller: Approx. 120 g

Degree of protection                Main unit: IP20, Terminal unit: IP00

Memory protection                   Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                          CX-Thermo version 4.6 or higher

                                    E5DC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the

Setup Tool port                     computer. *5

                                    E5DC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are

                                    used together to connect a USB port on the computer.*5

Standards   Approved standards      UL 61010-1, CSA C22.2 No. 611010-1 (evaluated by UL), Korean Radio Waves Act (Act 10564)

            Conformed standards     EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II

                                    EMI:                                                     EN61326

                                    Radiated Interference Electromagnetic Field Strength:    EN55011            Group 1, class A

                                    Noise Terminal Voltage:                                  EN55011            Group 1, class A

                                    EMS:                                                     EN61326

EMC                                 ESD Immunity:                                            EN61000-4-2

                                    Electromagnetic Field Immunity:                          EN61000-4-3

                                    Burst Noise Immunity:                                    EN61000-4-4

                                    Conduction Disturbance Immunity:                         EN61000-4-6

                                    Surge Immunity:                                          EN61000-4-5

                                    Voltage Dip/Interrupting Immunity:                       EN61000-4-11

*1  The indication accuracy of K thermocouples in the −200 to 1,300°C range, T and N thermocouples at a temperature of −100°C or less, and U

    and L thermocouples at any temperature is ±2°C ±1 digit max. The indication accuracy of B thermocouples at a temperature of 400°C max. is

    not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max.

    The indication accuracy of R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W

    thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.

    The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.

*2  Ambient temperature: −10 to 23 to 55°C, Voltage range: −15% to 10% of rated voltage

*3  K thermocouple at −100°C max: ±10°C max.

*4  The unit is determined by the setting of the Integral/Derivative Time Unit parameter.

*5  External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.

                                                                                                                                               39
E5DC

USB-Serial Conversion Cable                                                       Communications Functions

Specifications                                                                                                                  You can use the memory in the PLC to read and write

    Applicable OS            Windows 2000, XP, Vista, or 7                                                                      E5@C parameters, start and stop operation, etc.

                                                                                                                                The E5@C automatically performs communications

    Applicable software      CX-Thermo version 4.6 or higher                                                                    with the PLC. No communications programming is re-

    Applicable models        E5@C Series and E5CB Series                             Programless                                quired.

                                                                                     communications *                           Number of connected Digital Temperature Controllers:

    USB interface stan-      Conforms to USB Specification 2.0                                                                  32 max.

    dard                                                                                                                        Applicable PLCs: OMRON PLCs

    DTE speed                38,400 bps                                                                                                  SYSMAC CS Series, CJ Series, or CP Series

                                                                                                                                     Mitsubishi Electric PLCs

    Connector                Computer: USB (Type A plug)                                                                                 MELSEC Q Series or L Series

    specifications           Digital Temperature Controller: Special serial con-                                                When Digital Temperature Controllers are connected,

                             nector                                                                                             the parameters can be copied from the Digital Temper-

    Power supply             Bus power (supplied from the USB host controller) *                                                ature Controller that is set as the master to the Digital

    Power supply voltage     5 VDC                                                                                              Temperature Controllers that are set as slaves.

                                                                                                                                Number of connected Digital Temperature Controllers:

    Current consumption      450 mA max.                                             Communications                             32 max. (including master)

    Output voltage           4.7±0.2 VDC (Supplied from USB-Serial Conver-           between                                    When Digital Temperature Controllers are connected,

                             sion Cable to the Digital Temperature Controller.)      components *                               set points and RUN/STOP commands can be sent from

                             250 mA max. (Supplied from USB-Serial Conver-                                                      the Digital Temperature Controller that is set as the

    Output current           sion Cable to the Digital Temperature Controller.)                                                 master to the Digital Temperature Controllers that are

                                                                                                                                set as slaves.

    Ambient operating        0 to 55°C (with no condensation or icing)                                                          Slope and offsets can be set for the set point.

    temperature                                                                                                                 Number of connected Digital Temperature Controllers:

    Ambient operating                                                                                                           32 max. (including master)

    humidity                 10% to 80%                                           MELSEC is a registered trademark of Mitsubishi Electric Corporation.

    Storage temperature      −20 to 60°C (with no condensation or icing)          *                        A Digital Temperature Controller with version 1.0 or higher is required.

    Storage humidity         10% to 80%                                           Current Transformer (Order Separately)

    Altitude                 2,000 m max.

    Weight                   Approx. 120 g                                        Ratings

Windows is a registered trademark of Microsoft Corporation in the United             Dielectric strength                                 1,000 VAC for 1 min

States and other countries.                                                          Vibration resistance                                50 Hz, 98 m/s2

*   Use a high-power port for the USB port.                                          Weight                                              E54-CT1: Approx. 11.5 g,

Note: A driver must be installed on the computer. Refer to the                                                                           E54-CT3: Approx. 50 g

          Instruction Manual included with the Cable for the installation            Accessories (E54-CT3 only)                          Armatures (2)

          procedure.                                                                                                                     Plugs (2)

Communications Specifications                                                     Heater Burnout Alarms and SSR Failure

    Transmission line connection     RS-485: Multidrop                            Alarms

    method

    Communications                   RS-485 (two-wire, half-duplex)                  CT input (for heater current                        Models with detection for single-phase heat-

    Synchronization method           Start-stop synchronization                      detection)                                          ers: 1 input

    Protocol                         CompoWay/F or Modbus                            Maximum heater current                              50 A AC

    Baud rate                        9,600, 19,200, 38,400, or 57,600 bps            Input current                                       ±5% FS ±1 digit max.

                                                                                     indication accuracy

    Transmission code                ASCII                                           Heater burnout alarm                                0.1 to 49.9 A (in units of 0.1 A)

    Data bit length *                7 or 8 bits                                     setting range *1                                    Minimum detection ON time: 100 ms *3

    Stop bit length *                1 or 2 bits                                     SSR failure alarm setting                           0.1 to 49.9 A (in units of 0.1 A)

                                     Vertical parity (none, even, or odd)            range *2                                            Minimum detection OFF time: 100 ms *4

    Error detection                  Block check character (BCC)                  *1                       For heater burnout alarms, the heater current will be measured when the

                                     with CompoWay/F or                                                    control output is ON, and the output will turn ON if the heater current is

                                     CRC-16 with Modbus                                                    lower than the set value (i.e., heater burnout detection current value).

    Flow control                     None                                         *2                       For SSR failure alarms, the heater current will be measured when the

                                                                                                           control output is OFF, and the output will turn ON if the heater current is

    Interface                        RS-485                                                                higher than the set value (i.e., SSR failure detection current value).

    Retry function                   None                                         *3                       The value is 30 ms for a control period of 0.1 s or 0.2 s.

                                                                                  *4                       The value is 35 ms for a control period of 0.1 s or 0.2 s.

    Communications buffer            217 bytes

    Communications response          0 to 99 ms                                   Electrical Life Expectancy Curve for

    wait time                        Default: 20 ms

* The baud rate, data bit length, stop bit length, and vertical parity can        Control Output Relay (Reference Values)

    be individually set using the Communications Setting Level.                   Life (× 104 operations)  500

                                                                                                           300

                                                                                                           100

                                                                                                           50

                                                                                                           30

                                                                                                           10

                                                                                                           5       E5DC

                                                                                                           3       250 VAC, 30 VDC

                                                                                                                   (resistive load)

                                                                                                                   cosφ = 1

                                                                                                           1

                                                                                                                0  1         2       3          4   5           6

                                                                                                                                         Switching current (A)

40
                                                                                                                                                                                    E5DC

External Connections

E5DC

       Control output                Auxiliary outputs 1 and 2                          The E5DC is set for a K-type thermocouple (input type = 5) by default.

Relay output                      Relay outputs                                         An input error (s.err) will occur if the input type setting does not agree

250 VAC, 3 A (resistive load)     250 VAC: 2 A (resistive load)                         with the temperature sensor. Check the input type.

Voltage output (for driving SSR)

12 VDC, 21 mA                                                                                  E5DC

Linear current output

0 to 20 mA DC                                                                                        Control output            Options

4 to 20 mA DC

Load: 500 Ω max.                  Input Power Supply                                           Control Output

                                  100 to 240 VAC      24 VAC/DC                                         RX                 QX                         CX

                                                1                1                                   1 relay        1 voltage output               1 linear

                                                                                                     output         (for driving SSR)              current output

                                                2                2                                   5        R         5      +            Q      5                +  C

                                                      (no polarity)                                  6                  6      -                   6                -

                                                                                     1  5  9

                                                                                     2  6  10                    Auxiliary Outputs

                                  Options                                                                           9

                                  002                                                      11                       10     Auxiliary output 2

                                  Communications and          1  CT                                                        Auxiliary output 1

                                  B(+)                                                                              11

                                  RS-485        3                         7

                                                4     CT1                 8

                                  A(-)

                                  015                                                                         Sensor (Temperature/Analog) Input

                                  Communications                                                                    TC            Pt               I                   V

                                  B(+)                                                                              12     A      12           +   12                  12

                                                3                         7                12                    -         B                   mA

                                  RS-485                                                                            13            13               13               -  13

                                                4                         8          3  7  13                              B                   -       V

                                  A(-)                                                                        +     14            14               14               +  14

                                  016                                                4  8  14                 Do not connect anything to the terminals

                                  One event input                                                             that are shaded gray.

                                  -             3                         7

                                  +    EV1      4                         8

                                  017

                                  One event input and one CT

                                  -                3                      7

                                  +                   CT1                 8

                                       EV1         4

Note: 1.      The application of the terminals depends on the model.

       2.     Do not wire the terminals that are shown with a gray background.

       3.     When complying with EMC standards, the cable that connects the sensor must be 30 m or less. If the cable length                                              exceeds  30m,

              compliance with EMC standards will not be possible.

       4.     Connect M3 crimped terminals.

Isolation/Insulation Block Diagrams

                                       Sensor input and CT input

                                  Communications and event input

       Power           Voltage output (for driving SSR) and linear current   output

       supply

                                                Relay output

                                               Auxiliary outputs 1 and 2

                       : Reinforced insulation

                       : Functional isolation

Note:  Auxiliary       outputs 1 to 2 are not insulated.

                                                                                                                                                                                          41
E5DC

Nomenclature

E5DC                                                    Front panel

                                                                               No. 1 display                                             Bottom  View  of  E5DC

              Operation indicators                                             PV or specified parameter

                                                                               No.2 display

                                                                            SP or specified parameter value

             Press O Key once to go to                                         Use the M Key to change to another

             Adjustment Level.                                                 parameter.

             Press O Key for at least 3                                        Use the U D Keys to                 Bottom-

             seconds to go to Initial                                          set the parameter.                  panel Setup

             Setting Level.                                                                                        Tool port

      Use S Key to change the digit (default setting).                         Front-panel Setup Tool port

Dimensions                                                                                                                                                       (Unit: mm)

Controllers

E5DC                                                                           (85)

                                                                 4             81

                                             22.5                                                                  22.5

                                96                                                                 35     110  91

                                                                                                   4

                                                        Mounting Adapter

                                                              (Accessory: Sold separately)

                                The Setup Tool port is on the bottom of the Temperature Controller.

                                It is used to connect the Temperature Controller to the computer to use the Setup Tool.

                                The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.

                                Refer to the instructions that are provided with the USB-Serial Conversion Cable for the

                                connection procedure.

                                Note: Do not leave the USB-Serial Conversion Cable connected when you use

                                             the Digital Temperature Controller.

                                Mounted Separately                   Two-Unit Mounting                    Group Mounted

                                                                                                          (22.5 × number of units) +1.0
                                                                                                                         0
                                                        22.7  +0.3                   +0.6
                                                                               45
                                                              0                      0

                                92     +0.8                          92  +0.8                      92  +0.8

                                       0                                 0                             0

                                                        120 min

                                • Recommended panel thickness is 1 to 8 mm.

                                • Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.)

                                • When two or more Digital Temperature Controllers are mounted, make sure that the surrounding temperature does

                                not exceed the allowable operating temperature specified in the specifications.

                                • To attach the USB-Serial Conversion Cable to the control panel, use a panel thickness of 1 to 2.5 mm.

42
                                                                                                                                                                                                     E5DC

Accessories (Order Separately)

● USB-Serial Conversion Cable                                                                                                       (2110)

E58-CIFQ2                                                250                                                                                      263                                    1510

                                                                                         LED (RD)

                                          USB connector

                                          (type A plug)                                                                                                                                             Serial connector

                                                                                                                                    LED (PWR)

                                                                                                                                    LED (SD)

● Conversion Cable

E58-CIFQ2-E

         Conversion Cable                       Connecting to               the     E58-CIFQ2 USB-Serial Conversion Cable

                                                                                                                                    (2110)

                      (1510)                                       250                                                                            263                                       1510

Note: Always use this product together    with the  E58-CIFQ2.                           E58-CIFQ2  (sold separately)                                                               Conversion Cable

● Current Transformers

E54-CT1                                                                                             Thru-current (Io) vs. Output Voltage (Eo) (Reference                                              Values)

                                                21                          2.8

                                                15       5.8 dia.                                   E54-CT1

                                                                                                    Maximum continuous heater current:                                          50 A (50/60 Hz)

                                                                                    7.5             Number of windings:                                                         400±2

                                                                                                    Winding resistance:                                                         18±2 Ω

                              25      3

                                                                                                    Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

                                                                   10.5

                                                                                                                                    10                          ∞                   Distortion

                                                40                                                                                                1kΩ                               factor

                                                         Two, 3.5 dia.                                                              1                                               10%

                                                                                                                                                                                    3%

                                      10                                                                                                                                        1%

                                                                                                                                    100mV

                                                30

                                                                                                                                    10                                100Ω

E54-CT3                                                                  2.36 dia.

                                          30                                                                                        1                                 RL=10Ω

                                                         12 dia.

                                                                                    9

                                                                                                                                    100μV

                              40 × 40                                                                                               10

                                                                                                                                           1  10  100mA            1        10      100  1,000A

                                                                                                                                                                      Thru-current (Io) A (r.m.s.)

                                                                                                    Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)

                                                    Two , M3 holes (depth:     4)                   E54-CT3

                                  15                                                                Maximum continuous heater current: 120 A (50/60 Hz) (Maximum

                                                                                                    continuous heater current for an OMRON Digital Temperature Con-

                                                                                                    troller is 50 A.)

                                          30                                                        Number of windings: 400±2

E54-CT3 Accessories                                                                                 Winding resistance: 8±0.8 Ω

                                                                                                    Output voltage (Eo) V (r.m.s.)  100V      Frequency: 50 Hz

• Armature                            Connection    Example                                                                                                     ∞                        Distortion

                                                                                                                                    10            1kΩ                                    factor

                                                         Armature                                                                                                                        10%

Approx. 3 dia.                            Plug                                                                                                    500Ω                                   3%

                                                                                                                                    1                                                   1%

                                                                         Lead

                                                                                                                                    100mV

                                                                                                                                                                            100Ω

                      18                                                                                                            10                                50Ω

• Plug                                                                                                                                                                RL=10Ω

                                                                                                                                    1

Approx. 6 dia.                                                                                                                      100μV

                (22)                                                                                                                10

                                                                                                                                           1  10  100mA            1        10      100  1,000A

                                                                                                                                                                      Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                      43
E5DC

    ●  Mounting Adapters                                                                 ●  Short Bars

    Y92F-53 (Two included.)                                                              Y92S-P11 (Four included.)

This accessory is not included with the                                                  Use this product to connect between       terminals (for power supplies,

product. Order it separately to mount                                                    communications, etc.) when you use        multiple E5DC Controllers.

the product to a panel.

                                                                                                                                                           27.5

                                                           34.7                                                                        2.4

                                                                                                                                                           22.5

                                         12

                                                                                                                                            24.8

                             11.8        9.4                                                                                           0.8

                                                                                                                                                                     3

                                                                                                                                                                     5

    ●  End Plate                                                                         ● DIN Tracks

    PFP-M                                                                                PFP-100N

                                                                                         PFP-50N

                                                                 10

                                                                     6.2

                                                                             1.8

                                       M4×8

                                       pan head

                                       screw                         1

                             50                                              35.5  35.3

                                                                        1.8

                             11.5

                                                 10                  1.3                                                                                   7.3±0.15

                                         M4 spring washer            4.8                    4.5

                                                                                                                                                           35±0.3    27±0.15

                                                                                                 15  25  10  25                25  10  25         15 (5)*            1

                                                                                                                 1000  (500)*

                                                                                                                 *     Dimensions      in parentheses are for the    PFP-50N.

    ● Spacer                                                                             ● Unit Labels

    PFP-S                                                                                Y92S-L2

                                                                     16

                                                     5               12                                                        The Unit Labels for the Digital Panel

                                                                                                                               Meter are used. Use either the °C or °F

                                                                                                                               label from the sheet.

                                                                             34.8

                                                           44.3

                                                                     16.5

44
MEMO

      45
    E5CC/E5EC/E5AC/E5DC

Operation

Setting Levels Diagram

This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords.                                         Some

parameters are not displayed depending on the protect level setting and the conditions of use.

Control stops when you move from the operation level to the initial setting level.

                                                                                                      Press the O and M             Protect Level

                Only when Manual Mode was                                                             Keys for at least 1 s.

                used just before power OFF                                                                                          Used to set protection

                                                                   Power ON                                                         for operations.

                Press the O Key or the                                                                                                         Press the O and      M

                S Key for at least 1 s.                       Level changes                                                                                            Keys

                                                              automatically.                                                                   for at least 3 s.*2

     Operating  Manual Control                                     Operation Level                         O Key once.        Adjustment Level

                Level                                              Used for SP, alarm values,                                 Used to change adjustment

                Used to set the                                    and other basic settings                                   parameters (PID constants,

                MV manually.                                       and monitoring.                         O Key once.        adjustment sensitivity, etc.).

                O Key pressed for at least 3 s *2

                or S Key pressed for at least 1 s *1

                while A-M is displayed

                                        Press the O Key                                       Press the O Key

                                        for at least 3 s.*2                                   for at least 1 s.

                                                                                                           Press O Key once

                                                                                                           (models with communications only).

                                                                Initial Setting Level                                         Communications

                                                                   Used to set the input type                                       Setting Level

                                                                   and other basic settings.                                  Used to set communications.

                                                                                                           O Key once.

                                   Release protection and then

                                   enter the password (−169)                                               O Key for at least 1 s.

     Stopped.                      for the amoV (Move to Advanced                              Press  the

                                   Setting Level) parameter.

                                                                   Advanced Function

                                                                   Setting Level

                                                                   Used to set application

                                                                              functions.

                                        Enter the password

                                        (1201) for the Move to

                                        Calibration Level parameter.

                                                                   Calibration Level

*1.  To use a key procedure to     move to Manual Control Level, set the Auto/Manual Select Addition parameter to ON and set the PF                           Setting  parameter  to  a-m  (Auto/

     Manual).

*2.  The No. 1 display will flash  in the middle when the keys are pressed for 1 s or longer.

46
                                                                                                           E5CC/E5EC/E5AC/E5DC

Error Displays (Troubleshooting)

When an error occurs, the No. 1 display or No. 2 display shows the error code.

Take necessary measure according to the error code, referring the following table.

Display       Name                       Meaning                                    Action                                      Operation

                                                                                                                 After the error occurs and it is

                        The input value exceeded the control        Check the wiring for input to be sure        displayed, the alarm output will

                        range.*                                     it is wired correctly, not broken, and       operate as if the upper limit was

                        The input type is not set correctly.        not shorted. Also check the input            exceeded.

                        The sensor is disconnected or short-        type.                                        It will also operate as if transfer

                        circuited.                                  If there are no problems in the wiring       output exceeded the upper limit.

                        The sensor is not wired correctly.          or input type settings, cycle the            If an input error is assigned to a

                        The sensor is not wired.                    power supply.                                control output or auxiliary output, the

                                                                    If the display remains the same,             output will turn ON when the input

s.err                   *  Control Range                            replace the Digital Temperature              error occurs.

         Input error    Temperature resistance                      Controller.                                  The error message will appear in the

                        thermometer or thermocouple input:          If the display is restored to normal,        display for the PV.

                           SP Lower Limit - 20°C to SP Upper        then the probable cause is external

                           Limit + 20°C                             noise affecting the control system.          Note: 1.  The heating and cooling

                           (SP Lower Limit - 40°F to SP Upper       Check for external noise.                              control outputs will turn

                           Limit + 40°F)                                                                                   OFF.

                        ESIB input:                                 Note: For a temperature resistance           2.        When the manual MV, MV

                           Same as specified input range.                       thermometer, the input is                  at stop, or MV at error is

                        Analog input:                                           considered disconnected if                 set, the control output is

                           Scaling range -5% to 105%                            the A, B, or B’ line is broken.            determined by the set

                                                                                                                           value.

                                          This is not an error. It

                                          is displayed when the                                                  Control continues and operation is

[[[[                    Below -1,999      control range is wider                                                 normal.

                                          than the display                                                       The value will appear in the display

         Display                          range and the PV                                                       for the PV.

         range                            exceeds the display                       -                            Refer to the E5@C Digital

         exceeded                         range. The PV is                                                       Temperature Controllers User’s

                                          displayed for the                                                      Manual (Cat. No. H174) for

]]]]                    Above 9,999       range that is given on                                                 information on the

                                          the left (the number                                                   controllable range.

                                          without the decimal

                                          point).

                                                                    First, cycle the power supply.

                                                                    If the display remains the same, the         The control outputs, auxiliary

e333     A/D            There is an error in the internal           controller must be repaired.                 outputs, and transfer outputs turn

         converter      circuits.                                   If the display is restored to normal,        OFF. (A current output will be approx.

         error                                                      then a probable cause can be                 0 mA and a linear voltage output will

                                                                    external noise affecting the control         be approx. 0V.)

                                                                    system. Check for external noise.

                                                                    First, cycle the power supply.

                                                                    If the display remains the same, the         The control outputs, auxiliary

e111     Memory         There is an error in the internal           controller must be repaired.                 outputs, and transfer outputs turn

         error          memory operation.                           If the display is restored to normal,        OFF. (A current output will be approx.

                                                                    then a probable cause can be                 0 mA and a linear voltage output will

                                                                    external noise affecting the control         be approx. 0V.)

                                                                    system. Check for external noise.

                                                                                                                 Control continues and operation is

                                                                                                                 normal.

                                                                                                                 The error message will appear for the

ffff     Overcurrent    This error is displayed when the peak                       -                            following displays.

                        current exceeds 55.0 A.                                                                  Heater Current Value 1 Monitor

                                                                                                                 Heater Current Value 2 Monitor

                                                                                                                 Leakage Current Value 1 Monitor

                                                                                                                 Leakage Current Value 2 Monitor

                                                                                                                 The No. 1 display for the following

ct1                                                                                                              parameter flashes in Operation Level

                                                                                                                 or Adjustment Level.

ct2      HB or HS       If there is a HB or HS alarm, the No.                                                    Heater Current Value 1 Monitor

lcr1     alarm          1 display will flash in the relevant                        -                            Heater Current Value 2 Monitor

                        setting level.                                                                           Leakage Current Value 1 Monitor

lcr2                                                                                                             Leakage Current Value 2 Monitor

                                                                                                                 However, control continues and

                                                                                                                 operation is normal.

                        "----" will be displayed for the Valve

                        Opening Monitor parameter if any of

                        the following error occurs.

         Potentiometer  • Motor calibration has not been                                                         Close control: The control output is

         Input Error       performed.                                                                            OFF or the value that is set for the

----     (Position-     • The wiring of the potentiometer is        Check for the above errors.                  MV at PV Error parameter is output.

         proportional      incorrect or broken.                                                                  Floating control: Operation will be

         Models Only)   • The potentiometer input value is                                                       normal.

                           incorrect (e.g., the input is out of

                           range or the potentiometer has

                           failed).

                                                                                                                                                          47
    E5CC/E5EC/E5AC/E5DC

Operation

Parameters

The related setting items in each level are described below. If you press the Mode Key at the last setting item, the display will return to the first

setting item in the same level.

                                                                                                                    Power ON                                                                                                                                  S Key*2

                                                                                    Starting  in  Manual Mode.                                                                                       Press the O Key for at least 3 s.

                                                                                                     Manual Control Level                                                 Starting in                Other than the Auto/Manual Switch display                                               S Key*2

                                                                                                                                                                          Automatic

                                                                                                                               Press the O                                Mode.                                                                               Initial Setting Level

                                 Press the S Key                                                              PID              Key or the S                                                                                                    Press the

                                 for at least 1 s.                                                C       25  Control                                                                                                                                               Press the O Key for less than 1 s.

                                                     *1                                                   0   only             Key for at least                                                                                                O Key for

                                                                                                  PV/MV                        1 s.                  *1                                                                                        at least 1 s.

                                                                                                                                                                                                                                                                    in-t Input Type

    Adjustment                   Press the O Key less than 1      s.                                                                                                                                                                                                           5

    Level                                                                                                                                   Operation Level                                                                                                                   M

                                 Press the O Key less than        1 s.                                                                                                                                                                                              in-h Scaling Upper Limit

           Adjustment Level                                                                                                                                                                                                                                                   100

           Display                                                                                                                                                                                                                                                            M

           Displayed only                                                                                           25         Process Value/                             al1h              Alarm Value

    l.adj  once when                                                                                                        0  Set Point 1                                               0  Upper Limit                                                             in-l            Scaling Lower Limit

           entering              ins    Process Value Input           orl    MV Change Rate                                                                                                 1                                                                                  0

           adjustment level.     0.0    Shift                           0    Limit                                       M                                                       M

    M                            M                                      M                                           25         Process Value/                             al1l              Alarm Value                                                                       M

                                                                                                                            0  Set Point 2                                                  Lower Limit                                                                       dp    Decimal Point

    at     AT Execute/Cancel     inrt                                        Position                                                                                                    0  1                                                                                  0    For input type of analog

                                        Process Value Slope             db                                               M                                                       M

    off                          1.000  Coefficient                     2.0  Proportional                                                                                                                     Set either of these parameters.                                 M

                                                                             Dead Band *4                           a-m        Auto/Manual Switch                         al-2              Alarm

    M                            M                                      M                                                      PID control only.                                            Value 2                                                                       d-u       Temperature Unit

           Communications                                                                                                      Added when                                                0                                                                                          °C, °F

    cmwt   Writing               rss    Remote SP Input Shift     oc-h       Open/Close           Press the              M auto/manual select                                                                                                                                  c             For input type of

    off                          0.0    *4                                   Hysteresis *4        O Key                        addition is ON.                                   M                                                                                                           temperature

                                                                        0.8                       for at      m-sp             Multi-SP Set                                                 Alarm Value                                                                       M

    M                            M                                      M                         least 3 s.                0  Point Selection                            al2h              Upper Limit                                                             sl-h            SP Upper Limit

    spmd   SP Mode               rsrt   Remote SP Input                      Extraction of                                                                                               0  2                                                                                 1300

    lsp    *4                    1.000  Slope Coefficient         sqrp       Square Root                                 M                                                       M                                                                                            M

                                        *4                              0    Low-cut Point                          rsp                                                   al2l              Alarm Value                                                                                     Limit the set point

    M                            M                                                                                             Remote SP Monitor                                            Lower Limit                                                             sl-l            SP Lower Limit

                                                                        M                                                0.0   *4                                                        0  2

    ct1    Heater Current 1      p      Proportional Band         w1on       Work Bit 1                                  M                                                                                                                                                    -200

    0.0    Value Monitor         8.0                                         ON Delay                                                                                            M                            Set either of these parameters.                                 M

                                 M                                                                            sp-m             Set Point During                           al-3              Alarm

    M                                                                   M                                                   0  SP Ramp                                                      Value 3                                                                 cntl            PID ON/OFF

                                 i      Integral Time                                                                                                                                    0                                                                                    onof

    hb1    Heater Burnout                                         w1of       Work Bit 1                                  M                                                       M

           Detection 1           233                                                                                                                                                                                                                                          M

    0.0                                                                      OFF Delay                        ct-1             Heater Current     1  Value                                  Alarm Value

    M                            M                PID settings                                                                 Monitor                                    al3h              Upper Limit                                                             s-hc            Standard or

                                 d      Derivative Time                 M                                                0.0                                                             0  3                                                                                 stnd  Heating/Cooling

    ct2    Heater Current 2                                       w2on       Work Bit 2                                  M                                                       M

    0.0    Value Monitor         40                                                                                                                                                                                                                                           M

           *4                                                                ON Delay                         ct-2             Heater Current     2  Value                al3l              Alarm Value

    M                            M                                                                                             Monitor                                                      Lower Limit                                                                       st    ST (Self-tuning)

                                                                        M                                                0.0   *4                                                        0  3                                                                                       For input type of

    hb2    Heater Burnout        c-p    Proportional Band                                                                                                                                                                                                                     on    temperature, standard

           Detection 2           8.0    (Cooling)                 w2of       Work Bit 2                                  M                                                       M                            Set either of these parameters.                                 M     control, or PID

    0.0    *4                                                                OFF Delay                        lcr1             Leakage Current 1                          al-4              Alarm

    M                            M                                      M                                                      Monitor                                                      Value 4                                                                 ptrn            Program Pattern

                                                                                                                         0.0                                                             0                                                                                    off

    lcr1   Leakage Current    1  c-i    Integral Time                                                                    M                                                       M                                                                                                  When assigning PID or

    0.0    Monitor               233                              w3on       Work Bit 3                                                                                                                                                                                       M     control output to ON/OFF

                                        (Cooling)                            ON Delay                                          Leakage Current 2                                            Alarm Value                                                                             output

    M                            M                                      M                                     lcr2             Monitor                                    al4h              Upper Limit

                                                                                                                         0.0   *4                                                        0  4                                                                                 cp    Control Period (Heating)

    hs1    HS Alarm 1            c-d    Derivative Time           w3of                                                   M                                                       M                                                                                            20

    50.0                         40     (Cooling)                            Work Bit 3                                                                                                                                                                                                     Set the ON/OFF

                                                                             OFF Delay                        prst             Program Start                              al4l              Alarm Value                                                                       M             output cycle.

    M                            M                                      M                                           rset                                                                 0  Lower Limit                                                             c-cp            Control Period (Cooling)

           Leakage Current    2                                                                                                                                                             4

    lcr2   Monitor               c-db   Dead Band                 w4on       Work Bit 4                                  M                                                       M                                                                                            20

    0.0    *4                    0.0                                         ON Delay                         sktr             Soak Time Remain                                                                                                                               M

    M                                                                                                                                                                                    o  MV Monitor

                                 M                                      M                                                   0                                                    0.0        (Heating)                                                               orev Direct/Reverse Operation

    hs2    HS Alarm 2            of-r   Manual Reset Value                                                               M                                                       M                                                                                            or-r

           *4                           Clear the offset during   w4of       Work Bit 4

    50.0                         50.0   stabilization of P or PD             OFF Delay                              r-s        RUN/STOP                                   c-o               MV Monitor                                                                        M

    M                            M      control.                                                                         run                                                                (Cooling)

                                                                        M                                                                                                        0.0                                                                                alt1 Alarm 1 Type

    sp-0   SP 0                  hys    Hysteresis (Heating)                                                             M                                                       M                                                                                             2

       0                         1.0                              w5on       Work Bit 5

                                                                             ON Delay                         al-1             Alarm        Set either of                 v-m               Valve Opening                                                                     M

    M                            M          Hysteresis settings                                                             0  Value 1      these                                           Monitor *4

                                                                        M                                                                                                        0.0                                                                                alh1            Alarm 1

    sp-1   SP 1                  chys   Hysteresis (Cooling)                                                             M                  parameters.                          M                                                                                            0.2   Hysteresis

       0                         1.0                              w5of       Work Bit 5                                                                                                                                                                                       M

                                                                             OFF Delay

    M                            M                                      M                                 Press the O and M Keys for                                  Press the O and       M Keys             Press the O Key

    sp-2   SP 2                  soak   Soak Time                                                         at least 3 s.                                               for at least 1 s.                        less than 1 s.

       0                         1                                w6on       Work Bit 6                                                                                          Communications

    M                                                                        ON Delay                                       Protect Level

                                 M                                      M                                                                                                        Setting Level

    sp-3   SP 3                  wt-b   Wait Band                                                             The time taken to move to the protect level                        Displayed only for models with                                               * Used with programless communications

                                                                  w6of       Work Bit 6                       can be adjusted by changing the "Move to                           communications. Changes are

       0                         off                                                                          protect level time" setting.                                       effective after cycling power or

    M                                                                        OFF Delay                                                                                           after a software reset.

                                                                                                              pmov          Move to Protect Level:                                                                                                                                          up     1    Upload

    sp-4                         mv-s   MV at Stop                      M                                                0  Displayed only when a                                                                                                                                                   0   Setting 1

           SP  4                                                                                                            password is set. Restricts                           psel               Protocol Setting:                          maxu                 Highest

       0                         0.0                              w7on       Work Bit 7                       M             moving to protect level.                                                Switches between                                                Communications               M

    M                                                                        ON Delay                                                                                                          cwf  CompoWay/F and                                            0     Unit No.

                                 M                                                                                          Operation/Adjustment Protect:                                           Modbus.                                                   M *3                          up13        Upload

    sp-5                         mv-e   MV at PV Error                  M                                     oapt0         Restricts displaying and                                           M                                                                                                    0   Setting 13

           SP  5                                                                                                            modifying menus in operation,                        u-no               Communications                             area                 Area

       0                         0.0                              w7of       Work Bit 7                                     adjustment, and manual                                                  Unit No.                                                                                     M

    M                            M                                           OFF Delay                              M control levels.                                                          1                                                              0                                         Download

                                                                        M                                     icpt          Initial Setting/Communications Protect:                            M                                                              M                             dn     1    Setting 1

    sp-6                         sprt   SP Ramp Set Value                                                                   This protect level restricts movement to                                                                                                                                0

           SP  6                                                                                                         1  the initial setting, communications setting,                 bps        Communications                             adrh                 First Address

       0                         off                              w8on       Work Bit 8                             M and advanced function setting levels.                                         Baud Rate                                                       Upper Word                   M

    M                            M                                           ON Delay                                                                                                          9.6  CompoWay/F                                                0                             dn13        Download

                                                                                                              wtptoff       Setting Change Protect:                                            M    only                                                      M                                         Setting 13

    sp-7   SP  7                 sprl   SP Ramp Fall Value              M                                                   Protects changes to setups by                                                                                                                                       1000

                                                                                                                            operating the front panel keys.                              len        Communications                             adrl                 First Address                M

       0                         same                             w8of       Work Bit 8                             M                                                                               Data Length                                                     Lower Word

    M                            M                                           OFF Delay                                                                                                         7                                                              0                             copy           Copy

                                                                        M                                     pfpt PF Key Protect                                                              M                                                              M                                  off       *3

                                 ol-h   MV Upper Limit                                                              off                                                          sbit               Communications                                                  Receive Data

                                 100.0                            plcm       Communications                         M                                                                               Stop Bits                                  rwat                 Wait Time

                                                                      1234   Monitor                          chgp Changed Parameters Only                                                     2                                                              1000  *3                       sps        SP Slope

                                 M                                      M                                           off                                                                        M                                                              M                                 1.000      *3

                                 ol-l   MV Lower Limit                                                              M                                                            prty               Communications                             unit                 Communications               M

                                 0.0                                                                                                                                                        even    Parity                                                          Node Number

                                                                                                              pmsk Parameter Mask Enable:                                                                                                                     0                             spos           SP Offset

                                 M                                                                                  on      Displayed only when a                                              M                                                              M                                    0.0     *3

                                                                                                                            parameter mask is set.

                                                                                                                    M                                                            sdwt               Send Data Wait                                                                               M

                                                                                                              prlp Password to Move to                                                         20   Time

                                                                                                                         0  Protect Level:                                                     M                                               *1. When the PF Setting parameter is set to A-M.

                                                                                                                            Password setting                                                                                                   *2. When the PF Setting parameter is set to PFDP.

                                                                                                                    M                                                                                                                          *3. Used with component communications.

                                                                                                                                                                                                                                               *4. Not displayed by the E5DC.

48
                                                                                                                                                                             E5CC/E5EC/E5AC/E5DC

                    Monitor/Setting Item Level

                                25    Monitor/Setting  S                Monitor/Setting        S            Monitor/Setting          S                                       Monitor/Setting  S                 Monitor/Setting

                                      Item Display 1                    Item Display 2                      Item Display 3                                                   Item Display 4                     Item Display 5

                                   0

                           Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level).

                           Press the O Key

                           for at least 1 s.

                                                       Advanced Function Setting Level

alt2   Alarm 2 Type

2

M                                                                                                                                                                        RT

alh2   Alarm 2                                            init       Parameter Initialization     ret       Automatic Display           rt                                                    sptr     SP Tracking

       Hysteresis                                         off                                     off       Return Time                 off                                                      off

0.2

M                                                         M                                       M                                     M                                                        M

alt3                                                      mspu       Number of Multi-SP           brgt      Display Brightness          hsu                              HS Alarm Use         p-db     PV Dead Band

       Alarm 3 Type                                       off        Points                       3                                                                 on                           0

2

M                                                         M                                       M                                     M                                                        M

                                                          spru       SP Ramp Time Unit            a1lt      Alarm 1 Latch               hsl                              HS Alarm Latch       manl     Manual MV

alh3   Alarm 3                                                                                                                                                                                         Limit Enable

0.2    Hysteresis                                         m                                       off                                   off                                                      off

M                                                         M                                       M                                     M                                                        M

                                                          rest       Standby Sequence             a2lt      Alarm 2 Latch               hsh                              HS Alarm Hysteresis  pmvd     Direct Setting of

alt4   Alarm 4 Type                                       a          Reset                                                                                          0.1                          off   Position Proportional

2                                                                                                 off                                                                                                  MV *4

M                                                         M                                       M                                     M                                                        M

alh4   Alarm 4                                            sb1n       Auxiliary Output 1           a3lt      Alarm 3 Latch               lba                              LBA Detection Time   pvrp     PV Rate of Change

       Hysteresis                                         n-o        Open in Alarm                off                                                               0                            20    Calculation Period

0.2

M                                                         M                                       M                                     M                                                        M

o1st                                                      sb2n       Auxiliary Output 2           a4lt      Alarm 4 Latch               lbal                             LBA Level            hctm     Heating/Cooling

       Control Output   1  Signal                         n-o        Open in Alarm                off                                                               8.0                          off   Tuning Method

4-20                                                                                                                                    M

M                                                         M                                       M                                                                                              M

                                                          sb3n       Auxiliary Output 3           prlt      Move to Protect Level       lbab                             LBA Band             ompw     Minimum Output

o2st  &nb