电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

E5CZ-Q2MLD AC/DC24

器件型号:E5CZ-Q2MLD AC/DC24
器件类别:热门应用    测试测量   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:  
下载文档

器件描述

mexla TC voltageout 2alm 24vdc

参数
Datasheets:
E5CZ/E5CZ-U:
PCN Design/Specification:
Multiple devices Modification July/2013:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Controllers - Process, Temperature
Series: E5CZ
Type: Process Controller
Input Range: 0 ~ 20mA, 0 ~ 10VDC
Output Type: Relay (2), Voltage (External SSR)
Control Method: On/Off, Proportional (PID)
Communications: Option Cards Available
Number Of Characters Per Row: 4, 4
Display Type: LCD - Dual Color Characters, Backlight
Display Characters - Height: 0.433" (11.00mm), 0.256" (6.50mm)
Voltage - Supply: 24VAC/DC
Panel Cutout Dimensions: Square - 45.00mm x 45.00mm
Mounting Type: Panel Mount
Termination Style: Screw Terminal
Ingress Protection: IP66 (Face), IP20 (Case), IP00 (Terminal)
Operating Temperature: -10°C ~ 55°C
Features: Option Cards Available
Weight: 0.331 lb (150.14g)
Associated Product: Y92F-45-ND - ADAPTER FOR E5B FRONT PANELE53-CZHB-ND - ACCY EVENT INPUT UNIT OPTIONE53-CZH03-ND - ACCY COMMUNICATION UNIT RS485E53-CZB-ND - ACCY EVENT INPUT UNIT OPTIONE53-CZ03-ND - ACCY COMMUNICATION UNIT RS485E53-COV17-ND - ACCY TERM COVER FOR E5CNY92S-29-ND - RUBBER GASKET FOR H5CLY92A-48G-ND - TERM COVER FINGER SAFE H3CR-FE58-CIFQ1-ND - CABLE USB-SERIAL CONVERSIONE54-CT3-ND - TRANSFORMER CURRENT 12MM DIAZ3224-ND - SOCKET 11-PIN FOR H7CNZ2416-ND - TRANSFORMER CURRNT 50A E5AK/E5CKZ2250-ND - SOCKET 11 PIN OCTAL CHASSIS MNTZ884-ND - SOCKET DIN MNT 11PIN SCREW TERM
Other Names: E5CZQ2MLDACDC24

E5CZ-Q2MLD AC/DC24器件文档内容

Digital Temperature Controllers

E5CZ

Next-generation Digital Temperature                                                    48 48 78 mm (W H D)
Controller
                                                                                                                                                                                                                                                   
Depth of only 78 mm.
Various temperature inputs: thermocouple, platinum resistance

  thermometer, infrared temperature sensor, and analog inputs.
Auto-tuning and self-tuning are available. Auto-tuning is possi-

  ble even while self-tuning is being executed.
Heating or heating/cooling control is available.
Start/stop function.
CE marking and UL/CSA approval.
Models with optional functions and current output added to the

  series.

       Refer to the "Safety Precautions" on page 52.

Model Number Structure

Model Number Legend                                                   3. Option Unit
                                                                           Blank: Not available
E5CZ- @ 2 @ @                                                              M: Option Unit can be mounted

               123 4                                                   4. Power supply voltage
1. Output type                                                             Blank: 100 to 240 VAC
                                                                           D: 24 VAC/VDC
    R: Relay
    Q: Voltage (for driving SSR)
    C: Current
2. Number of alarms
    2: Two alarms

Ordering Information

List of Models

          Size               Power supply     Number of                Control output        Option Unit                       Model
                                 voltage     alarm points
                                                                                       Not Available                  E5CZ-R2
1/16 DIN                     100 to 240 VAC  2                Relay                    Not Available                  E5CZ-Q2
                                                                                       Available                      E5CZ-R2M
48 48 78 mm (W H D)                                   Voltage for driving SSR  Available                      E5CZ-Q2M
                                                                                       Available                      E5CZ-C2M
                                                              Relay                    Available                      E5CZ-R2MD
                                                                                       Available                      E5CZ-Q2MD
                                                              Voltage for driving SSR  Available                      E5CZ-C2MD

                                                              Current

                             24 VAC/VDC      2                Relay

                                                              Voltage for driving SSR

                                                              Current

Option Units

The E5CZ-@2M provides communications or event input functionality when one of the following Option Units is mounted.

Communications  Heater burnout                   Functions                                                                     Model
Communications  Heater burnout                                                                                        E53-CNH03N
                                                Event inputs                                                          E53-CN03N
                                                Event inputs                                                          E53-CNHBN
                                                                                                                      E53-CNBN

12        Digital Temperature Controllers E5CZ
Accessories (Order Separately)

Current Transformers (CTs)

Model                E54-CT1                E54-CT3
Hole diameter        5.8 dia.               12.0 dia.

Specifications

Ratings

Power supply voltage                  100 to 240 VAC, 50/60 Hz                            24 VAC/VDC, 50/60 Hz

Operating voltage range               85% to 110% of rated supply voltage

Power consumption                     7 VA                                                5 VA, 3 W

Sensor input                          Thermocouple:                    K, J, T, E, L, U, N, R, S, B

                                      Platinum resistance thermometer: Pt100, JPt100

                                      Infrared temperature sensor:     10 to 70C, 60 to 120C, 115 to 165C, 140 to 260C

                                      Voltage input:                   0 to 50 mV

Control output Relay output           SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations

                  Voltage output      12 VDC +15%/-20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
                  Current output      4 to 20 mA DC, load: 600  max., resolution: approx. 2,600

Alarm output                          SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations

Event input       Contact input       ON: 1 k max., OFF: 100 k min.

                  Non-contact input ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

                                      Outflow current: Approx. 7 mA per point

Control method                        2-PID control or ON/OFF control

Setting method                        Digital setting using front panel keys

Indication method                     7-segment digital display and single-lighting indicators
                                      Character height: PV: 10.0 mm; SV: 6.5 mm

Other functions                       According to Controller model

Ambient operating temperature -10 to 55C (with no condensation or icing)

Ambient operating humidity            25% to 85%

Storage temperature                   -25 to 65C (with no condensation or icing)

Input Ranges

Platinum Resistance Thermometer Input

Input type                      Pt100                        JPt100

Temperature -200 to           -199.9 to  0.0 to        -199.9 to 0.0 to
                              500.0C    100.0C       500.0C 100.0C
range            850C
                              1          2
Setting number 0                                       3         4

Thermocouple Input

Input type              K                J                T              E         L            U        N             R           S      B

Temperature -200 to -20 to         -100 to -20.0 to -200 to -199.9 to 0 to     -100 to -200 to -199.9 to -200 to 0 to 0 to 100 to
                                   850C 400.0C 400C 400.0C 600C           850C 400C 400.0C 1300C 1700C 1700C 1800C
range            1300C 500C

Setting number 5           6       7     8         9      22         10        11     12        23   13            14          15     16

Shaded setting indicates the default setting.

ES1B Infrared Temperature Sensor

    Input type 10 to 70C       60 to 120C 115 to 165C 140 to 260C
                               0 to 120C 0 to 165C 0 to 260C
Temperature 0 to 90C
range                          18              19            20

Setting number 17

                                                                               Digital Temperature Controllers E5CZ                          13
Analog Input

Input type                0 to 50 mV

Setting range Usable in the following ranges by scaling:
                        -1999 to 9999 or -199.9 to 999.9

Setting number 21

Applicable standards by input type are as follows:

K: GB/T 2814-98
J,L: GB/T 4994-98
T,U: GB/T 2903-98
E: GB/T 4993-98
N: GB/T 17615-98
R: GB/T 1598-98
S: GB/T 3772-98
B: GB/T 2902-99
JPt100, Pt100: GB/T 5977-99

Characteristics

Indication accuracy       Thermocouple:
                          (0.5% of indicated value or 1C, whichever is greater) 1 digit max. (See note 1.)
Influence of temperature
(See note 2.)             Platinum resistance thermometer:
Influence of voltage      (0.5% of indicated value or 1C, whichever is greater) 1 digit max.
(See note 2.)
                          Analog input: 0.5% FS1 digit max.
Hysteresis
Proportional band (P)     CT input: 5% FS1 digit max.
Integral time (I)
Derivative time (D)       R, S, and B thermocouple inputs:
Control period            (1% of PV or 10C, whichever is greater) 1 digit max.
Manual reset value
Alarm setting range       Other thermocouple inputs:
Sampling period           (1% of PV or 4C, whichever is greater) 1 digit max.
Insulation resistance
Dielectric strength       *10C for -100C or less for K sensors
Vibration resistance
Shock resistance          Platinum resistance thermometer inputs:
Weight                    (1% of PV or 2C, whichever is greater) 1 digit max.
Memory protection
EMC                       Analog inputs:
                          (1% of FS) 1 digit max.
Applicable standards
                          0.1 to 999.9 EU (in units of 0.1 EU)

                          0.1 to 999.9 EU (in units of 0.1 EU)

                          0 to 3999 s (in units of 1 s)

                          0 to 3999 s (in units of 1 s)

                          1 to 99 s (in units of 1 s)

                          0.0% to 100.0% (in units of 0.1%)

                          -1999 to 9999 (decimal point position depends on input type)

                          500 ms

                          20 M min. (at 500 VDC)

                          2,000 VAC, 50 or 60 Hz for 1min (between current-carrying terminals of different polarity)

                          10 to 55 Hz, 20 m/s2 for 10 min in X, Y and Z directions

                          100 m/s2, 3 times each in 3 axes, 6 directions

                          Approx. 150 g

                          EEPROM (non-volatile memory) (number of write operations: 100,000)

                          Enclosure Emission:                EN 55011 (GB/T 6113.1,2) Group 1 Class A

                          AC Mains Emission:                 EN 55011 (GB/T 6113.1,2) Group 1 Class A

                          ESD Immunity:                      IEC 61000-4-2 (GB/T 17626.2) 4 kV contact discharge (level 2)

                                                                                        8 kV air discharge (level 3)

                          RF-interference Immunity:          IEC 61000-4-3 (GB/T 17626.3): 10 V/m, 80 MHz to 1 GHz (level 3)

                          Conducted Disturbance Immunity: IEC 61000-4-6 (GB/T 17626.6): 3 V (0.15 to 80 MHz) (level 3)

                          Burst Immunity:                    IEC 61000-4-5 (GB/T 17626.5): 2 kV powerline (level 3)

                                                                                        2 kV I/O signalline (level 4)

                          UL 61010C-1, CSA C22.2 No.1010.1
                          Conforms to EN 61326, EN 61010-1 (IEC 61010-1).

Note 1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max. and
          U and L thermocouples at any temperature is 2C 1 digit maximum. The indication accuracy of the B thermocouples at a temperature
          of 400C max. is not specified.
          The indication accuracy of the R and S thermocouples at a temperature of 200C max. is 3C 1 digit maximum.

       2. Conditions: Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to +10% of rated voltage.

       3. When using the E53-CN03N or E53-CNBN Option Unit with the E5CZ-C2M or E5CZ-C2M to satisfy the Class A limit for the radiated in-
          terference field strength test, always connect a ZCAT2235-1030 Clamp Filter (manufactured by TDK) to the power line of the Temperature
          Controller.

14          Digital Temperature Controllers E5CZ
Dimensions

Note: All units are in millimeters unless otherwise indicated.

                                                                                                                                                                  Panel Cutouts

                                                                                                                                                            Mounted separately  Group Mounted

                                                                                                                                                                                (48        No.  of  units  -2.5)  +1.0
                                                                                                                                                                                                                    0

ALM1                    PV                                                                                                                                                                                         +0.6
ALM2                    SV                                                                                                                                                                                           0

OUT1 STOP
OUT2

                                                                                                                                                                                                                   45

                                                                                                                           48.8                             45  +0.6
                                                                                                                                 48.8                            0

                        E5CZ                                                                                                                    60 min

                                                                                                                                                                      +0.6
                                                                                                                                                                        0

                                                                                             102                                                                      45

           48                                                                                93

                                                  6                                      78

e ALM1              PV                                                                                                                                      Recommended panel thickness is 1 to 8 mm.
                    SV                                                                                                                                      Group mounting is not possible in the vertical direction.
ALM2                                                                                                                                                        (Maintain the specified mounting space between Controllers
               E5CZ                                                                                                                                         when they are group mounted.)
OUT1 STOP
OUT2                                                                                                                                                        When two or more Controllers are mounted, make sure that
                                                                                                                                                            the surrounding temperature does not exceed the allowable
                                              58                                                                                                            operating temperature specified in the specifications.

Current Transformers                                                                              21                               2.8
                                                                                                  15                                          7.5
E54-CT1
                                                                                                                 5.8 dia.
                                                                              25 3
                                                                                                                           10.5
                                                                                     10
                                                                                                  40
E54-CT3                                                                                                             Two, 3.5 dia.

                                                                                                     30

                                                                                                                                     2.36 dia.
                                                                                                  30

                                                                                                                   12 dia.
                                                                                                                                                         9

                                                     40@

                                                                                                  Two, M3 holes (depth: 4)

                                                     15                                                                            Connection Example
                                                                              30
E54-CT3 Accessories                                                                                                                                                             Contact
                                                      Plug
Contact                                                                                                                                                   Plug
                                                      Approx. 6 dia.
  Approx. 3 dia.                                                                                                                                                                         Lead wire

                                          18                                                      (22)

                                                                                                                                                            Digital Temperature Controllers E5CZ                         15
Wiring Terminals

The voltage output (control output) is not electrically insulated from the internal circuits. When using a grounded thermocouple, do not connect
  the control output terminals to the ground. If the control output terminals are connected to the ground, errors will occur in the measured temper-
  ature values as a result of leakage current.

                Current output              Voltage output Relay output                                        Alarm output

    Control output 1 4 to 20 mA DC          12 VDC
                                            21 mA

                                                                                                               ALM2/Control ALM1/Heater

                                                                                                               output 2            burnout

                                            Analog input                                                       Input power supply

                                            Two input power supplies are available: 100 to 240 VAC or 24 VDC.

    Option Units                                                                       E53-CNBN
                                                                                       Event Inputs
    E53-CNHBN
    Event Inputs/Heater Burnout Detection

                Contact inputs Non-contact inputs                                                              Contact inputs Non-contact inputs

                Heater burnout detection input                                                                           Do not use.
                                                                                                                         Do not use.

    E53-CNH03N                              Host computer                              E53-CN03N
    Communications/Heater Burnout Detection                                                                                                                                         Host computerCommunications

                        RS-485                                                                       RS-485
                                                                                                     B (+)
                             B (+)                                                                    A (-)

                             A (-)                                                                  Do not use.
                                                                                                    Do not use.
                            Do not use.
                             Heater burnout detection input                                         Do not use.

Communications                              Event Inputs                                                       Heater Burnout Alarm

    Interface:  RS-485                          Contact Inputs                                                     Maximum heater current: 50 A AC
                                                  ON: 1 k max., OFF: 100 k min.                                    Input current indication accuracy:
    Synchronization: Start-stop
                            (asynchronous)      Non-Contact Inputs                                                   5% FS 1 digit max.
                                                  ON: residual voltage of 1.5 V max.                               Heater burnout alarm setting range:
    Communications: Half duplex                   OFF: leakage current of 0.1 mA max.
                                                                                                                     0.1 to 49.9 A, in 0.1 A increments
    Baud rate:  1.2/2.4/4.8/9.6/
                19.2 kbps

16              Digital Temperature Controllers E5CZ
Nomenclature

E5AZ                                                                    Temperature Unit                                              No. 1 Display
                                                                                                                                      Displays the process value or param-
       Operation Indicators                                             The temperature unit is displayed when the dis-               eter type.
       1. ALM1 (alarm 1)                                                play unit parameter is set to a temperature. In-
                                                                        dication is determined by the currently selected              No. 2 Display
            Lights when the alarm 1 output is ON.                       "temperature unit" parameter set value. When                  Displays the set point, manipulated
            ALM2 (alarm 2)                                              this parameter is set to "C," "c" is displayed,              variable, or set value (setup) of the
            Lights when the alarm 2 output is ON.                       and when set to "F," "f" is displayed.                       parameter.
            ALM3 (alarm 3)
            Lights when the alarm 3 output is ON.                       ALM1                                                          Up Key
       2. HB (heater burnout alarm display)                                                                                           Each press of this key increases val-
            Lights when a heater burnout is detected.                   ALM2                                              PV          ues displayed on the No.2 display.
            The heater burnout alarm can be held ON by setting the                                                                    Holding down this key continuously
            heater burnout latch. To reset, turn the power supply       ALM3                                                          increases values.
            OFF and then ON or set the heater burnout alarm value
            to 0.0 A.                                                   HB                                                            Down Key
       3. OUT1, OUT2 (control output 1, control output 2)                                                                             Each press of this key decreases val-
            Lights when control output 1 or control output 2 (cool) is  OUT1                                                          ues displayed on the No.2 display.
            ON.                                                                                                                       Holding down this key continuously de-
            However, if control output 1 is a current output, OUT1      OUT2                                                          creases values.
            will always be not lit.
       4. STOP (stop)                                                   STOP                                              SV
            Lights when control of the E5AZ has been stopped.
            During control, this indicator lights when an event or the  CMW
            run/stop function has become stopped. Otherwise, this
            indicator is not lit.                                                                        E5AZ                         Mode Key
       5. CMW (communications writing control)                                                                                        Press this key to select parameters
            Lights when communications writing is enabled and is        Level Key                                                     within each level.
            not lit when it is disabled.                                Press this key to select the setup level. The setup level is
                                                                        selected in order "operation level"  "adjustment level,"      Level + Mode Keys
E5EZ                                                                    "initial setting level"  "communications setting level."
                                                                                                                                      This key combination sets the E5AZ
     Operation Indicators                                                                                                             to the "protect level."
     1. ALM1 (alarm 1)
                                                                        Temperature Unit                                              No. 1 Display
          Lights when the alarm 1 output is ON.                                                                                       Displays the process value or param-
          ALM2 (alarm 2)                                                The temperature unit is displayed when the dis-               eter type.
          Lights when the alarm 2 output is ON.                         play unit parameter is set to a temperature. In-
          ALM3 (alarm 3)                                                dication is determined by the currently selected              No. 2 Display
          Lights when the alarm 3 output is ON.                         "temperature unit" parameter set value. When                  Displays the set point, manipulated
     2. HB (heater burnout alarm display)                               this parameter is set to "C," "c" is displayed,              variable, or set value (setup) of the pa-
          Lights when a heater burnout is detected.                     and when set to "F," "f" is displayed.                       rameter.
          The heater burnout alarm can be held ON by setting
          the heater burnout latch. To reset, turn the power                                      PV                                  Up Key
          supply OFF and then ON or set the heater burnout                                                                            Each press of this key increases val-
          alarm value to 0.0 A.                                               ALM1 ALM2 ALM3 HB                                       ues displayed on the No.2 display.
     3. OUT1, OUT2 (control output 1, control output 2)                                                                               Holding down this key continuously
          Lights when control output 1 or control output 2                    OUT1 OUT2 STOP CMW                                      increases values.
          (cool) is ON.
          However, if control output 1 is a current output, OUT1                                  SV                                  Down Key
          will always be not lit.                                                                                                     Each press of this key decreases val-
     4. STOP (stop)                                                                                                                   ues displayed on the No.2 display.
          Lights when control of the E5EZ has been                                                                                    Holding down this key continuously
          stopped.During control, this indicator lights when an                                                                       decreases values.
          event or the run/stop function has become stopped.
          Otherwise, this indicator is not lit.
     5. CMW (communications writing control)
          Lights when communications writing is enabled and
          is not lit when it is disabled.

                                                                                                                    E5EZ              Level Key
                                                                                                                                      Press this key to select the setup lev-
                                                                        Mode Key                                                      el. The setup level is selected in order
                                                                        Press this key to select parameters within                    "operation level"  "adjustment
                                                                        each level.                                                   level," "initial setting level"
                                                                                                                                      "communications setting level."

                                                                                                                                      Level + Mode Keys
                                                                                                                                      This key combination sets the E5EZ
                                                                                                                                      to the "protect level."

                                                                        Digital Temperature Controllers E5AZ/E5EZ/E5CZ                                                           17
E5CZ                                                      Temperature Unit                                              No. 1 Display
                                                                                                                        Displays the process value or parameter type.
          Operation Indicators                            The temperature unit is displayed when the dis-
                                                          play unit parameter is set to a temperature. Indi-            No. 2 Display
          1. ALM1 (alarm 1)                               cation is determined by the currently selected                Displays the set point, manipulated variable,
                Lights when the alarm 1 output is         "temperature unit" parameter set value. When                  or set value (setup) of the parameter.
               ON.                                        this parameter is set to "C," "c" is displayed, and
                ALM2 (alarm 2)                            when set to "F," "f" is displayed.
                Lights when the alarm 2 output is
               ON.                                        ALM1       PV                                                 Up Key
                                                                                                                        Each press of this key increases values
          2. HB (heater burnout alarm display)            ALM2                                                          displayed on the No.2 display. Holding
                Lights when a heater burnout is de-                                                                     down this key continuously increases
               tected.                                    HB                                                            values.
               The heater burnout alarm can be
               held ON by setting the heater burn-        OUT1 STOP  SV                                                 Down Key
               out latch. To reset, turn the power                                                                      Each press of this key decreases values
               supply OFF and then ON or set the          OUT2 CMW                                                      displayed on the No.2 display. Holding
               heater burnout alarm value to 0.0 A.                                                                     down this key continuously decreases
                                                                                                 E5CZ                   values.
          3. OUT1, OUT2 (control output 1, con-
               trol output 2)                             Level Key                                                     Mode Key
                Lights when control output 1 or con-      Press this key to select the setup level. The setup level is  Press this key to select parameters within
               trol output 2 (cool) is ON.                selected in order "operation level"  "adjustment level,"      each level.
                However, if control output 1 is a cur-    "initial setting level"  "communications setting level."      Level + Mode Keys
               rent output, OUT1 will always be not                                                                     This key combination sets the E5CZ to the
               lit.                                                                                                     "protect level."

          4. STP (stop)
                Lights when control of the E5CZ has
               been stopped.
                During control, this indicator lights
               when an event or the run/stop func-
               tion has become stopped. Otherwise,
               this indicator is not lit.

          5. CMW (communications writing con-
               trol)
                Lights when communications writing
               is enabled and is not lit when it is dis-
               abled.

18  Digital Temperature Controllers E5AZ/E5EZ/E5CZ
Operation

PID Control Using Autotuning                                      Typical Example

    Changing Parameters

                                                                                  Input type:  4 T thermocouple -200 to 400C

                                                                                  Control method: PID control

                                                                                  ST (self-tuning): OFF
                                                                                  Calculate PID constants by AT (auto-tuning).

                                                                                  Alarm type:  2 upper limit

                                                                                  Alarm value 1: 30C (For setting deviation)

                                                                                  Set point:   150C

         indicates that there is a pa-                            Setup procedure                         Power ON
         rameter. Keep on pressing                                   Power ON
         the mode key until the de-
         sired parameter is selected.

                                                                                     Operation level

Changing Set Values                                                                                                  Process value/
                                                                                                                     set point
         Use the or keys
         to change the set value                                                                                 Press key for at least three
         displayed in the setup                                                                                  seconds.
         menu.
                                                                                                                   Control stops.
Display                                                                              Initial setting level
                                                                                     Press                               Input type 4
E5AZ                                                              Set input          keys to select
                                                                  specifications     input type.                         In PID control
                     No. 1 display
                     No. 2 display                                Set control        Press
                                                                  specifications     keys to select
                                                                                     PID control.
E5EZ                                                              Self-tuning                                         To cancel ST    When set to ON,
                                                                                     Press                                            self-tuning operates.
                                                                                     keys to set
                    No. 1 display                                 Check control      ST to OFF.                       Control period  Recommended set-
                    No. 2 display                                 period                                              (heat) (unit:   tings: 20 seconds for
                                                                                     Check the                        seconds)        the relay output and
                                                                                     control period.                                  2 seconds for the
                                                                                                                      Alarm 1 type 2  SSR output.
                                                                                     Check alarm                      (upper-limit
E5CZ                                                              Check alarm type   type.                            alarm)
     No. 1 display
                                         PV/SP                                                                   Press key for at least one second.
   No. 2 display                        After AT execution.
                                                                                               Operation level

                                                                                     Press     keys

                                                                  Set the set point  to set set point to              PV/
                                                                                                                      SP 150
                                                                                     "150C."

                                        During AT execution.

                                                                                                                 Press key for less than one second.

                                        While AT is being         AT execution       Adjustment level                 To execute AT   Set to on for execut-
                                        executed, SP will flash.                                                                      ing AT and to off
                                                                                     Execute AT                                       for stopping AT.
                                          After AT execution.                        (auto-tuning).

                                                                                                                 Press key for less than one second.

                                        During AT execution.                           Operation level

                                                                                     Make sure                        PV/
                                                                                     that set point                   SP150
                                                                                     is "150C."

                                                                                                 Make sure that       During run
                                                                  Set operation status control is running.

                                                                  Set alarm values   Press                            Alarm

                                                                                     keys to set                      value 1
                                                                                                                      30
                                                                                     alarm value to
                                                                                     "30C."

                                                                  Start operation                    Start operation

                                                             Digital Temperature Controllers E5AZ/E5EZ/E5CZ                                                  19
Specification Setting after Turning ON Power

Outline of Operation Procedures

Key Operation

In the following descriptions, all the parameters are introduced in the display sequence. Some parameters may not be displayed depending on the
protect settings and operation conditions.

    Power ON

    Operation level              Adjustment level                                + key
                                                                             Display flashes when key pressed.
                          key                                     + key
                     Less than                                1 second min.      + key
                     1 second            key                                 3 seconds min.
                                     Display flashes when key held
        key       key                down for more than 1 second.
    1 second  3 seconds
    min.      min.                            Control stops.

          Initial setting level                 Communica-     Protect level        The time taken to move to the protect level
                                                tions setting                       can be adjusted by changing the "Move to
        key                          key level                                      protect level time" setting.
    1 second min.                Less than
                                 1 second                                           Note: Of these levels, the initial setting level, communications set-
                                                                                            ting level, advanced function setting level and calibration
                                 Password input                                             level can be used only when control has stopped. Note that
                                 set value "-169"                                           control is stopped when these four levels are selected.
                                                                                            When switched back to the operation level from one of
              Advanced function                                Control in progress          these levels, control will start.
              setting level                                    Control stopped
                                                               Level change

Description of Each Level

Operation Level                                                                     Protect Level

This level is displayed when you turn the power ON. You can move to                 To select this level, simultaneously press the and M keys for at
the protect level, initial setting level and adjustment level from this
level.                                                                              least 3 seconds. This level is to prevent unwanted or accidental mod-
                                                                                    ification of parameters. Protected levels will not be displayed, and so
Normally, select this level during operation. During operation, the                 the parameters in that level cannot be modified.
process value, set point and manipulated variable can be monitored,
and the alarm value and upper- and lower-limit alarms can be moni-                  Communications Setting Level
tored and modified.
                                                                                    To select this level, press the key once for less than one second in
Adjustment Level                                                                    the initial setting level. When the communications function is used,
                                                                                    set the communications conditions in this level. Communicating with
To select this level, press the key once for less than one second.                  a personal computer (host computer) allows set points to be read
                                                                                    and written, and manipulated variables to be monitored.
This level is for entering set values and offset values for control. This
level contains parameters for setting the set values, AT (auto-tuning),             Advanced Function Setting Level
communications writing enable/disable, hysteresis, multi-SP, input
shift values, heater burnout alarm (HBA) and PID constants. You can                 To select this level, you must enter the password ("-169") in the initial
move to the top parameter of the operation level or initial setting level           setting level.
from here.
                                                                                    You can move only to the calibration level from this level.
Initial Setting Level
                                                                                    This level is for setting the automatic return of display mode, MV lim-
To select this level, press the key for at least three seconds in the               iter, event input assignment, standby sequence, alarm hysteresis, ST
operation level. This level is for specifying the input type, selecting             (self-tune) and to move to the user calibration level.
the control method, control period, setting direct/reverse action and
alarm type. You can move to the advanced function setting level or
communications setting level from this initial setting level. To return to

the operation level, press the key for at least one second. To
move to the communications setting level, press the key once for
less than one second.

20  Digital Temperature Controllers E5AZ/E5EZ/E5CZ
Specification Setting after Turning ON Power

Initial Setting Level                                                         Initial setting level

This level is used for setting basic specifications of the Temperature                              Input type
Controller. Using this level, set the input type for selecting the input to
be connected such as the thermocouple or platinum resistance ther-                                  Scaling upper limit
mometer and set the range of set point and the alarm mode.
                                                                                                    Scaling lower limit
Power ON                                             + key
                                                                                                    Decimal point
                                                   Display flashes                                                              For analog input
                                                   when key pressed.                             Temperature
                                                                                                 unit                          Set the pulse output
Operation level               Adjustment level                                                                                 cycle.
                      key                                                                           SP upper limit

                Less than 1 second                 + key                                            SP lower limit

key              key                         1 second min.                                          PID ON/OFF

1 second min. 3 seconds             Control stops.            + key                                 Standard or heating/
                      min.                                                                          cooling
                                                            3 seconds                               Alarm output type
                                                            min.                                    ST
                                                                                                    (PID control)
Initial setting                     Communica-     Protect level                                    Control period (heating)
level                               tions setting                                                   Control period (cooling)
                                                                                                    (PID control)
                            key level                                                               (Heating/cooling setting)
                                                                                                    Direct/reverse operation
                            Less than 1 second

           key              Password input         The time taken to move
1 second min.               set value "-169"       to the protect level can
                                                   be adjusted by changing
     Advanced function                             the "Move to protect lev-
     setting level                                 el time" setting.

                                                   Control in progress
                                                   Control stopped
                                                   Level change

The move from the operation level to the initial setting level, press
key for three seconds or more.

The initial setting level is not displayed when "initial/communications
protection" is set to "2." This initial setting level can be used when
"initial setting/communications protection" is set to "0" or "1."

The "scaling upper limit," "scaling lower limit," and "decimal point"
parameters are displayed when an analog voltage input is selected
as the input type.

                                                                              Alarm 1 type

                                                                              Alarm 2 type                                     Select the alarm mode.
                                                                              Alarm 3 type                                     (Models with alarm
                                                                                                                               function)

                                                                              Move to advanced
                                                                              function setting level

                                                                              (Displayed when initial setting/communications protection
                                                                              is set to 0.)

                                                                              To return to the operation level, press the      key for longer than one
                                                                              second.

                                                                              * Not displayed as default setting.

                                                            Digital Temperature Controllers E5AZ/E5EZ/E5CZ                                             21
Input Type

When selecting the input type, follow the specifications listed in the following table.

                                                                  Specifications      Set Value                  Input Temperature Range
Platinum resistance thermometer input Pt100                                       0              -200 to 850 (C)/-300 to 1500 (F)
                                                                                  1              -199.9 to 500.0 (C)/-199.9 to 900.0 (F)
                                    JPt100                                        2              0.0 to 100.0 (C)/0.0 to 210.0 (F)
                                                                                  3              -199.9 to 500.0 (C)/-199.9 to 900.0 (F)
Thermocouple input                  K                                             4              0.0 to 100.0 (C)/0.0 to 210.0 (F)
                                                                                  5              -200 to 1300 (C)/-300 to 2300 (F)
                                    J                                             6              -20.0 to 500.0 (C)/0.0 to 900.0 (F)
                                                                                  7              -100 to 850 (C)/-100 to 1500 (F)
                                    T                                             8              -20.0 to 400.0 (C)/0.0 to 750.0 (F)
                                                                                  9              -200 to 400 (C)/-300 to 700 (F)
                                    E                                             22             -199.9 to 400.0 (C)/199.9 to 700.0 (F)
                                    L                                             10             0 to 600 (C)/0 to 1100 (F)
                                    U                                             11             -100 to 850 (C)/-100 to 1500 (F)
                                                                                  12             -200 to 400 (C)/-300 to 2300 (F)
Infrared Temperature Sensor (ES1B)  N                                             23             -199.9 to 400.0 (C)/199.9 to 700.0 (F)
Analog input                        R                                             13             -200 to 1300 (C)/-300 to 2300 (F)
                                    S                                             14             0 to 1700 (C)/0 to 3000 (F)
                                    B                                             15             0 to 1700 (C)/0 to 3000 (F)
                                    10 to 70C                                    16             100 to 1800 (C)/300 to 3200 (F)
                                    60 to 120C                                   17             0 to 90 (C)/0 to 190 (F)
                                    115 to 165C                                  18             0 to 120 (C)/0 to 240 (F)
                                    140 to 260C                                  19             0 to 165 (C)/0 to 320 (F)
                                    0 to 50 mV                                    20             0 to 260 (C)/0 to 500 (F)
                                                                                  21             One of the following ranges depending on the results
                                                                                                 of scaling: 1999 to 9999, 199.9 to 999.9

Note: The initial setting is 5: -200 to 850C/-300 to 2300F.

22  Digital Temperature Controllers E5AZ/E5EZ/E5CZ
Alarm Types

Select the alarm type from the 12 types listed in the following table.

      Set Value                    Alarm Type                                                  Alarm Output Operation

0                Alarm function OFF                                             When X is positive             When X is negative
1 (See note 1.)  Upper- and lower-limit (deviation)
                                                                 Output OFF

                                                                                                            (See note 2.)

2                Upper-limit (deviation)

3                Lower-limit (deviation)

4 (See note 1.)  Upper- and lower-limit range (deviation)                                                   (See note 3.)

5 (See note 1.)  Upper- and lower-limit with standby se-                                                    (See note 4.)
6                quence (deviation)
7                                                                               (See note 5.)
8                Upper-limit with standby sequence (de-
                 viation)

                 Lower-limit with standby sequence (de-
                 viation)

                 Absolute-value upper-limit

9                Absolute-value lower-limit

10               Absolute-value upper-limit with standby

                 sequence

11               Absolute-value lower-limit with standby

                 sequence

Note 1: With set values 1, 4 and 5, the upper and lower limit values            5: Set value: 5, Upper- and lower-limit with standby sequence
           can be set independently for each alarm type, and are ex-                alarm. Always OFF when the upper-limit and lower-limit hys-
           pressed as "L" and "H."                                                  teresis overlaps.
           Following operations are for cases when an alarm set point               Set the alarm types for alarm 1 and alarm 2 independently in
           is "X" or negative.                                                      the initial setting level. The default setting is 2 (upper limit).
                                                                                    With the E5AZ/E5EZ, perform settings similarly for alarm 3.
       2: Set value: 1, Upper- and lower-limit alarm

    Case 1       Case 2                     Case 3 (Always ON)                  Example: When the alarm is set ON at 110C/F or higher.

                                                                 =              When an alarm type other       When the absolute-value
                                                                                than the absolute-value        alarm is selected
                                                                             =  alarm is selected
    3: Set value: 4, Upper- and lower-limit range                                                              (For alarm types 8 to 11)
                                                                                (For alarm types 1 to 7)       The alarm value is set as
                                                                                The alarm value is set as a    an absolute value from the
                                                                                deviation from the set point.  alarm value of 0C/F.

                                                                                               Alarm value                 Alarm value

    Case 1       Case 2                     Case 3 (Always OFF)

                 LH

                                                                                               Set point                   0C/F
                                                                                               100C/F
                                                                 =

                                                                             =
    4: Set value: 5, Upper- and lower-limit with standby sequence

    Case 1       Case 2

                                            Example

    Same as for the upper- and lower-limit
    alarm. However, when the upper-limit
    and lower-limit hysteresis overlaps:
    Always OFF

                                                     Digital Temperature Controllers E5AZ/E5EZ/E5CZ                                       23
Parameters                                                                                                                                 key 1 s min.

Parameters related to setting items for each level are marked in                       Advanced Function Setting Level
boxes in the flowcharts and brief descriptions are given as required.
At the end of each setting item, press the mode key to return to the                                              Resets to the default value.
beginning of each level.
                                                                                       Parameter initialization

    Power ON                                                      + key                Number of multi-SP uses
                                                                                       Select 2 or 4.
                                                              Display flashes          Event input assignment 1
                                                              when key pressed.
                                                                                       Event input assignment 2
    Operation level        Adjustment level                                            Multi-SP uses                    Input setting:
                                                                                                                        Multi-SP/RUN/STOP
                          key
                     Less than 1 s                          + key
                                                        1 s min.

    key              key                  + key

    1 s min. 3 s min.               Display flashes when key held         + key
                                                                   3 s min.
                                    down for more than 1 s.

                                              Control stops.

    Initial setting level                Communica-                                    SP ramp set value
                                         tions setting                                 Rate of change during ramp
                                                                   Protect level
                                key level                                              Standby sequence reset method
                           Less than 1 s                       The time taken to        Restarting condition
                                                               move to the protect      after clearing standby
                                                               level can be adjusted
             key                  Password input               by changing the "Move   Alarm 1 open in alarm            ON/OFF setting of
    1 s min.                      set value "-169"             to protect level time"  Alarm 1 hysteresis               alarm output 1
                                                               setting.
                  Advanced function
                  setting level                               Control in progress

                                                              Control stopped          Alarm 2 open in alarm            ON/OFF setting of
                                                              Level change             Alarm 2 hysteresis               alarm output 2
                                                                                       Alarm 3 open in alarm
    Display                                                                            Alarm 3 hysteresis               ON/OFF setting of
          E5AZ                                                                                                          alarm output 3

                                                    No. 1 display                      Heater burnout detection
                                                    No. 2 display
                                                                                       Heater burnout latch
                                                                                       Latch after heater
                                                                                       burnout detection
                                                                                       Heater burnout hysteresis

                  E5EZ

                                              No. 1 display                            ST stable range                                          Note: To select advanced
                                              No. 2 display                                     For setting deviation.
                                                                                                                                                         function setting
                                                                                       
                                                                                       2-PID parameter                                                   level, you must

                                                                                       MV upper limit                   Limitations to MV                enter the password
                                                                                       MV lower limit                                                    ("-169") in the initial
                                                                                                                                                         setting level.

                  E5CZ

                               No. 1 display

                                                                                       Input digital filter

                          No. 2 display                                                 Additional PV display
                                                                                           Displayed first in the operation level
                                                                                                                                                Move to protect level time
                                                                                        MV display
                                                                                                                                                Input error output
                                                                                       Automatic return of display mode
                                                                                                                                                Cold junction
                                                                                       Alarm 1 ON delay                 Alarm                   compensating method
                                                                                       Alarm 2 ON delay                 ON/OFF
                                                                                       Alarm 3 ON delay                 delays                  MB command logic
                                                                                       Alarm 1 OFF delay                                        switching

                                                                                       Alarm 2 OFF delay

                                                                                       Alarm 3 OFF delay

24                Digital Temperature Controllers E5AZ/E5EZ/E5CZ
                  Initial Setting Level                              key 1 s min.      Power ON                            key Less than 1 s        Adjustment Level
                                                                     key 3 s min.  Operation Level                         key Less than 1 s

              Input type                                                           Process value  Add in the "additional                      AT execute/cancel
                                                                                                  PV display" parameter.

              Scaling upper limit                                                  Process value/set point                                    Communications writing
              Scaling lower limit
                                                   For analog input                                                                           Heater current
                                                                                                                                              value monitor
                                                                                   Multi-SP                                                                           HBA function
                                                                                   set point setting                                          Heater burnout
               Decimal point                                                       SP ramp monitor                                            detection
                 Number of displayed digits
                                                                                   Heater current value monitor                                SP 0
                                            c: C
              Temperature unit f: F

              SP upper limit                                                       Run/stop                                                   SP 1
              SP lower limit                                                                                                                  SP 2
                                                   Limit the set point.                                                                                               SP used by multi-SP

              PID ON/OFF                                                           Alarm value 1            Set either of                     SP 3
                   Select the control system.                                      Upper-limit              these
                                                                                   alarm value 1            parameters.                       Temperature input shift 1-point shift
              Standard or heating/cooling                                          Lower-limit
                                                                                   alarm value 1            Set either of
              ST                                                                   Alarm value 2            these                             Upper-limit             2-point shift (see note)
                                                                                   Upper-limit              parameters.                       temperature input
              Control period (heating)                                             alarm value 2                                              Lower-limit
                               OUT1                                                Lower-limit                                                temperature input
                                                                                   alarm value 2
              Control period (cooling)             Set the pulse
                               OUT2                output cycle.

                                                                                                                                              Proportional band P

              Direct/reverse operation                                             Alarm value 3                                              Integral time        I
              Controls the MV in response                                          Upper-limit                                                                             PID settings
              increases or decreases in the PV.                                    alarm value 3
                                                                                   Lower-limit              Set either of                     Derivative time D
               Alarm 1 type                                                        alarm value 3            these
                                                                                                            parameters.

              Alarm 2 type                         Select the alarm                                                                           Cooling coefficient     Used in heating and
                                                   mode.                                                                                      Dead band               cooling control

               Alarm 3 type                                                        MV monitor (heating)

              Move to advanced function                                            MV monitor (cooling)                                       Manual reset value      Clear the offset
              setting level                                                                                                                   Hysteresis (heating)    during stabilization
              Note: This parameter is not displayed as a default set-              The displays for parameters which can be                   Hysteresis (cooling)    of P or PD control.
                                                                                   switched (i.e., parameters other than simply
                      ting. To move to the advanced function setting               numerical ones) show the contents of those                                         Set hysteresis.
                      level, change the initial setting/communications             parameters.
                      protection setting from 1 to 0. (See page 26.)

                                                                                                                                                                              The 2-point shift setting is only possible when the
                                                                                                                                                                              input type is an infrared temperature sensor.

Note: These diagrams show all the parameters that may be displayed. Depending on the specifications of the model used, there may be some
        parameters that are not displayed.

Input Shift

All points in the sensor range are shifted by the value set as the tem-
perature input shift value.

Example

Input shift setting Temperature                       Temperature
                             measured by                  display
                                 sensor
                                                   100C
0 (no shift)      100C                            110C
                                                   90C
10 (shifted +10C) 100C

-10 (shifted -10C) 100C

                                                                                   Digital Temperature Controllers E5AZ/E5EZ/E5CZ                                                           25
Protect Level

       Operation/adjustment protection
                   Restricts displaying and modifying menus in operation,
                   adjustment, and manual control levels.

        Initial setting/communications protection
                   This protect level restricts movement to the initial setting,
                   communications setting, and advanced function setting levels.

       Setting change protection
                   Protects changes to setups by operating the front panel
                   keys.

Operation/Adjustment Protection

The following table shows the relationship between set values and
the range of protection.

       Level                             Set value

                                      0  1  2                     3

Operation level       PV                              
Adjustment level      PV/SP
                      Other                           

                                            X                     X

                                         X  X                     X

When this parameter is set to "0," parameters are not protected.

Default setting: 0

  : Can be displayed and changed

: Can be displayed
X : Cannot be displayed and move to other levels not possible

Initial Setting/Communications Protection

This protect level restricts movement to the initial setting level, com-
munications setting level and advanced function setting level.

   Set Initial setting level Communications Advanced

value                        setting level function setting

                                            level

0                                                   

1                                                   X

2                X                    X             X

Default setting: 1
: Move to other levels possible
X: Move to other levels not possible

Setting Change Protection

This protect level protects setup from being changed by operating
the keys on the front panel.

      Set value                              Description
OFF
ON                    Setup can be changed by key operation.

                      Setup cannot be changed by key operation.
                      (The protect level, can be changed.)

Default setting: OFF

26     Digital Temperature Controllers E5AZ/E5EZ/E5CZ
Communications Setting Level

Set the E5AZ/E5EZ/E5CZ communications specifications in the communications setting level. For setting communications parameters, use the
E5AZ/E5EZ/E5CZ panel. The communications parameters and their settings are listed in the following table.

                Parameter          Displayed characters                         Set (monitor) value                  Set value
Communications unit No.    u-no                                        0 to 99                       0.1 to 99
Baud rate                  bps                                         1.2/2.4/4.8/9.6/19.2 (kbps)   1.2/2.4/4.8/9.6/19.2
Data bits                  len                                         7/8 (bit)                     7/8 (bit)
Stop bits                  sbit                                        1/2                           1/2 (bit)
Parity                     prty                                        None, even, odd               none/euen/odd

Note: The highlighted values indicate default settings.                Set each communications parameter to match those of the communi-
                                                                       cating personal computer.
Before executing communications with the E5AZ/E5EZ/E5CZ, set
the communications unit No., baud rate, etc., through key operations   Communications Unit No. (u-no)
as described below. As for other operations, refer to relevant Opera-
tion Manual.                                                           When communicating with the host computer, the unit number must
                                                                       be set in each Temperature Controller so that the host computer can
1. Press the key for at least three seconds in the "operation          identify each Temperature Controller. The number can be set in a
    level." The level moves to the "initial setting level."            range from 0 to 99 in increments of 1. The default setting is 1. When
                                                                       using more than one Unit, be careful not to use the same number
2. Press the key for less than one second. The "initial setting        twice. Duplicate settings will cause malfunction. This value becomes
    level" moves to the "communications setting level."                valid when the power is turned OFF and ON again.

3. Pressing the      key advances the parameters as shown in the       Baud Rate (bps)

following figure.                                                      Use this parameter to set the speed of communications with the host
                                                                       computer. It can be set to one of the following values; 1.2 (1200 bps),
4. Press the     or        keys to change the parameter setups.        2.4 (2400 bps), 4.8 (4800 bps), 9.6 (9600 bps), and 19.2
                                                                       (19200 bps).
                           Communications                              This setting becomes valid when the power is turned OFF and ON
                           unit No.                                    again.

                           Baud rate

                           Data bits                                   Data Bits (len)
                           Stop bits
                                                                       Use this parameter to change the communications data bit length to
                                                                       7 bits or 8 bits.

                           Communications                              Stop Bits (sbit)
                           parity
                                                                       Use this parameter to change the communications stop bit to 1 or 2.

Note: On the E5AZ/E5EZ, the key is the      key.                       Communications parity (prty)

                                                                       Use this parameter to set the communications parity to None, Even,
                                                                       or Odd.

Troubleshooting

When an error occurs, an error code will be displayed on the No. 1 display. Check the contents of an error and take appropriate countermeasures.

No.1 display               Contents                                    Countermeasure                             Output status

                                                                                                     Control output Alarm output

s.err (S. Err)     Input error (See note.)  Check that the input wiring is correct, that there is no discon- OFF  Handled as ab-
                                            nection or short-circuit, and that the input type is correct.         normally high
                                            (Thermocouple input short-circuits cannot be detected.)               temperature

                   A/D converter error      After noting the error, reset the power. If the display does not OFF  OFF
                   (See note.)              change, replacement is necessary. If the error is removed, it
                                            is possible that the original error was caused by noise. Check
                                            that there are no possible sources of noise.

e111 (E111)        Memory error             Reset the power. If the display does not change, replacement OFF      OFF
h.err (H. Err)     HB error (See note.)     is necessary. If the error is removed, it is possible that the OFF    OFF
                                            original error was caused by noise. Check that there are no
                                            possible sources of noise.

Note 1. If the input is within the range for which control is possible but outside the displayable range (-1999 (-199.9) to 9999 (999.9)), (((( will be
          displayed if the value is less than -1999 (-199.9), and )))) will be displayed if it is greater than 9999 (999.9). Control output and alarm
          output will operate normally for either of these displays. Refer to the relevant User's Manual for details on the ranges for which control is
          possible.

       2. These errors are displayed only when the Controller is set to display the present value or the present value and the set value. They are not
          displayed in other statuses.

                                                  Digital Temperature Controllers E5AZ/E5EZ/E5CZ                                 27
Peripheral Devices                                                                                                               Load
                                                                                                                                 Heater
Temperature Sensor / SSR
                                                                                                                                         Load power
Connection Example with SSR

                          Temperature Controller

                                      Voltage output
                                      terminal
                                      (for driving SSR)

                                                                             Direct connection possible

                                                 E5AZ                                                                  3 units    G3PB (Single-phase): 240 VAC
                                                                                                                       5 units                                   (15 A, 25 A, 35 A, 45 A)
                                                                                                                       (E5AZ/
                                                                                                                       E5EZ)     Rated input voltage:
                                                                                                                                 12 to 24 VDC

                                           ALM1

                                           ALM2                                                                    PV

                                           ALM3                                                                                  Compact and slim models with a
                                                                                                                                 built-in radiator
                                           HB

                                           OUT1

                                           OUT2

                                           STOP                                                                    SV

                                           CMW

                                                                                                                       2 units    G3PB (Three-phase): 240 VAC/400 VAC
                                                                                                                       4 units                                   (15 A, 25 A, 35 A, 45 A)
                                                                                                                       (E5AZ/
                                                                                                                       E5EZ)     Rated input voltage:
                                                                                                                                 12 to 24 VDC
                                                                        E5AZ
         E52
                                                 E5EZ
                                                                                                                                 Simultaneous three-phase control with
                                                                                                                                 a built-in radiator

                                                                                                         PV            3 units    G3PA: 240 VAC (10 A, 20 A, 40 A)
                                                                                                                       5 units              400 VAC (20 A, 30 A)
                                                 ALM1 ALM2 ALM3 HB                                                     (E5AZ/
                                                                                                                       E5EZ)     Rated input voltage:
                                                                                                                                 5 to 24 VDC

                                                 OUT1 OUT2 STOP CMW                                                              Compact and slim models with a
                                                                                                                                 built-in radiator
                                                                                                         SV

         ES1B                                                                                            E5EZ           3 units   G3NA: 240 VAC (5 A, 10 A, 20 A, 40 A)
                                                                                                                        5 units             480 VAC (10 A, 20 A, 40 A)
                                                       E5CZ                                                             (E5AZ/
                                                                                                                        E5EZ)    Rated input voltage:
                                                                                                                                 5 to 24 VDC
                                                                                                                       4 units
                                                                                                                       for          Standard models with screw terminals
                                                                                                                       480-VAC
                                                                                                                       models

                                                 ALM1                                                          PV      1 unit          G3NE: 240 VAC (5 A, 10 A, 20 A)
                                                                                                                       2 units
                                                 ALM2                                                                  (E5AZ/    Rated input voltage:
                                                                                                                       E5EZ)     12 VDC
                                                 OUT1 STOP                                                     SV

                                                 OUT2

                                                                                                             E5CZ

                                                                                                                                 Compact and low-cost models
                                                                                                                                 with tab terminals

Number of Connectable SSRs

           A: G3PB      B: G3PB    C: G3NA D: G3NE                                                         E: G3NH     4 units          G3NH: 440 VAC (75 A, 150 A)
            (Single-     (Three-  (See note.)                                                                          8 units
            phase)        phase)                                                                         4 units       (E5AZ/    Rated input voltage:
                                                                                                         8 units       E5EZ)     5 to 24 VDC
             G3PA     4 units
E5AZ/EZ               2 units     5 units  2 units
E5CZ     5 units                  3 units  1 unit

         3 units

Note: 480 VAC models: 4 units                                                                                                    For controlling high-power heater

28       Digital Temperature Controllers E5AZ/E5EZ/E5CZ
Terms and Conditions of Sale

1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed                      ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
     part of all quotes, agreements, purchase orders, acknowledgments, price lists,              BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
     catalogs, manuals, brochures and other documents, whether electronic or in                  PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
     writing, relating to the sale of products or services (collectively, the "Products")        INTENDED USE. Omron further disclaims all warranties and responsibility of
     by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron                      any type for claims or expenses based on infringement by the Products or oth-
     objects to any terms or conditions proposed in Buyer's purchase order or other              erwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obli-
     documents which are inconsistent with, or in addition to, these Terms.                      gation hereunder shall be, at Omron's election, to (i) replace (in the form
                                                                                                 originally shipped with Buyer responsible for labor charges for removal or
2. Prices; Payment Terms. All prices stated are current, subject to change with-                 replacement thereof) the non-complying Product, (ii) repair the non-complying
     out notice by Omron. Omron reserves the right to increase or decrease prices                Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
     on any unshipped portions of outstanding orders. Payments for Products are                  the non-complying Product; provided that in no event shall Omron be responsi-
     due net 30 days unless otherwise stated in the invoice.                                     ble for warranty, repair, indemnity or any other claims or expenses regarding
                                                                                                 the Products unless Omron's analysis confirms that the Products were prop-
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices              erly handled, stored, installed and maintained and not subject to contamina-
     sent to Buyer after deducting transportation charges, taxes and duties, and will            tion, abuse, misuse or inappropriate modification. Return of any Products by
     be allowed only if (i) the invoice is paid according to Omron's payment terms               Buyer must be approved in writing by Omron before shipment. Omron Compa-
     and (ii) Buyer has no past due amounts.                                                     nies shall not be liable for the suitability or unsuitability or the results from the
                                                                                                 use of Products in combination with any electrical or electronic components,
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or                 circuits, system assemblies or any other materials or substances or environ-
     the maximum legal rate, whichever is less, on any balance not paid within the               ments. Any advice, recommendations or information given orally or in writing,
     stated terms.                                                                               are not to be construed as an amendment or addition to the above warranty.
                                                                                                 See http://www.omron247.com or contact your Omron representative for pub-
5. Orders. Omron will accept no order less than $200 net billing.                                lished information.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all               14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
                                                                                                 FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
     costs involved in, obtaining any government approvals required for the impor-               LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
     tation or sale of the Products.                                                             WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
7. Taxes. All taxes, duties and other governmental charges (other than general                   BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
     real property and income taxes), including any interest or penalties thereon,               Further, in no event shall liability of Omron Companies exceed the individual
     imposed directly or indirectly on Omron or required to be collected directly or             price of the Product on which liability is asserted.
     indirectly by Omron for the manufacture, production, sale, delivery, importa-          15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
     tion, consumption or use of the Products sold hereunder (including customs                  their employees from and against all liabilities, losses, claims, costs and
     duties and sales, excise, use, turnover and license taxes) shall be charged to              expenses (including attorney's fees and expenses) related to any claim, inves-
     and remitted by Buyer to Omron.                                                             tigation, litigation or proceeding (whether or not Omron is a party) which arises
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory              or is alleged to arise from Buyer's acts or omissions under these Terms or in
     to Omron, Omron reserves the right to stop shipments or require satisfactory                any way with respect to the Products. Without limiting the foregoing, Buyer (at
     security or payment in advance. If Buyer fails to make payment or otherwise                 its own expense) shall indemnify and hold harmless Omron and defend or set-
     comply with these Terms or any related agreement, Omron may (without liabil-                tle any action brought against such Companies to the extent based on a claim
     ity and in addition to other remedies) cancel any unshipped portion of Prod-                that any Product made to Buyer specifications infringed intellectual property
     ucts sold hereunder and stop any Products in transit until Buyer pays all                   rights of another party.
     amounts, including amounts payable hereunder, whether or not then due,                 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
     which are owing to it by Buyer. Buyer shall in any event remain liable for all              sive property of Omron Companies and Buyer shall not attempt to duplicate it
     unpaid accounts.                                                                            in any way without the written permission of Omron. Notwithstanding any
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation                     charges to Buyer for engineering or tooling, all engineering and tooling shall
     unless Buyer indemnifies Omron against all related costs or expenses.                       remain the exclusive property of Omron. All information and materials supplied
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery                by Omron to Buyer relating to the Products are confidential and proprietary,
     resulting from causes beyond its control, including earthquakes, fires, floods,             and Buyer shall limit distribution thereof to its trusted employees and strictly
     strikes or other labor disputes, shortage of labor or materials, accidents to               prevent disclosure to any third party.
     machinery, acts of sabotage, riots, delay in or lack of transportation or the          17. Export Controls. Buyer shall comply with all applicable laws, regulations and
     requirements of any government authority.                                                   licenses regarding (i) export of products or information; (iii) sale of products to
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:                   "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of
     a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship              regulated technology or information.
                                                                                            18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
        except in "break down" situations.                                                       and no course of dealing between Buyer and Omron shall operate as a waiver
     b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall          of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
                                                                                                 without Omron's written consent. (c) Law. These Terms are governed by the
        constitute delivery to Buyer;                                                            law of the jurisdiction of the home office of the Omron company from which
     c. All sales and shipments of Products shall be FOB shipping point (unless oth-             Buyer is purchasing the Products (without regard to conflict of law princi-
                                                                                                 ples). (d) Amendment. These Terms constitute the entire agreement between
        erwise stated in writing by Omron), at which point title and risk of loss shall          Buyer and Omron relating to the Products, and no provision may be changed
        pass from Omron to Buyer; provided that Omron shall retain a security inter-             or waived unless in writing signed by the parties. (e) Severability. If any provi-
        est in the Products until the full purchase price is paid;                               sion hereof is rendered ineffective or invalid, such provision shall not invalidate
     d. Delivery and shipping dates are estimates only; and                                      any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
     e. Omron will package Products as it deems proper for protection against nor-               against the amount owing in respect of this invoice. (g) Definitions. As used
        mal handling and extra charges apply to special conditions.                              herein, "including" means "including without limitation"; and "Omron Compa-
12. Claims. Any claim by Buyer against Omron for shortage or damage to the                       nies" (or similar words) mean Omron Corporation and any direct or indirect
     Products occurring before delivery to the carrier must be presented in writing              subsidiary or affiliate thereof.
     to Omron within 30 days of receipt of shipment and include the original trans-
     portation bill signed by the carrier noting that the carrier received the Products
     from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the
     Products will be free from defects in materials and workmanship for a period of
     twelve months from the date of sale by Omron (or such other period expressed
     in writing by Omron). Omron disclaims all other warranties, express or implied.
     (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
     EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1. Suitability of Use. Omron Companies shall not be responsible for conformity                   ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROP-
     with any standards, codes or regulations which apply to the combination of the              ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
     Product in the Buyer's application or use of the Product. At Buyer's request,               OVERALL EQUIPMENT OR SYSTEM.
     Omron will provide applicable third party certification documents identifying          2. Programmable Products. Omron Companies shall not be responsible for the
     ratings and limitations of use which apply to the Product. This information by              user's programming of a programmable Product, or any consequence thereof.
     itself is not sufficient for a complete determination of the suitability of the Prod-  3. Performance Data. Data presented in Omron Company websites, catalogs
     uct in combination with the end product, machine, system, or other application              and other materials is provided as a guide for the user in determining suitabil-
     or use. Buyer shall be solely responsible for determining appropriateness of                ity and does not constitute a warranty. It may represent the result of Omron's
     the particular Product with respect to Buyer's application, product or system.              test conditions, and the user must correlate it to actual application require-
     Buyer shall take application responsibility in all cases but the following is a             ments. Actual performance is subject to the Omron's Warranty and Limitations
     non-exhaustive list of applications for which particular attention must be given:           of Liability.
     (i) Outdoor use, uses involving potential chemical contamination or electrical         4. Change in Specifications. Product specifications and accessories may be
     interference, or conditions or uses not described in this document.                         changed at any time based on improvements and other reasons. It is our prac-
     (ii) Use in consumer products or any use in significant quantities.                         tice to change part numbers when published ratings or features are changed,
     (iii) Energy control systems, combustion systems, railroad systems, aviation                or when significant construction changes are made. However, some specifica-
     systems, medical equipment, amusement machines, vehicles, safety equip-                     tions of the Product may be changed without any notice. When in doubt, spe-
     ment, and installations subject to separate industry or government regulations.             cial part numbers may be assigned to fix or establish key specifications for
     (iv) Systems, machines and equipment that could present a risk to life or prop-             your application. Please consult with your Omron's representative at any time
     erty. Please know and observe all prohibitions of use applicable to this Prod-              to confirm actual specifications of purchased Product.
     uct.                                                                                   5. Errors and Omissions. Information presented by Omron Companies has been
     NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS                                  checked and is believed to be accurate; however, no responsibility is assumed
     RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT                                     for clerical, typographical or proofreading errors or omissions.
     ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
OMRON INDUSTRIAL AUTOMATION THE AMERICAS HEADQUARTERS
Schaumburg, IL USA 847.843.7900 800.556.6766 www.omron247.com

OMRON CANADA, INC. HEAD OFFICE                                       OMRON ARGENTINA SALES OFFICE
Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com   Cono Sur 54.11.4783.5300

OMRON ELECTRONICS DE MEXICO HEAD OFFICE                              OMRON CHILE SALES OFFICE
Mxico DF 52.55.59.01.43.00 001.800.556.6766 mela@omron.com      Santiago 56.9.9917.3920

OMRON ELECTRONICS DE MEXICO SALES OFFICE                             OTHER OMRON LATIN AMERICA SALES
Apodaca, N.L. 52.81.11.56.99.20 001.800.556.6766 mela@omron.com  54.11.4783.5300

OMRON ELETRNICA DO BRASIL LTDA HEAD OFFICE
So Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br

OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00
Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu

Cat. No. DS-E5CZ 05/08 Note: Specifications are subject to change.      2013 Omron Electronics LLC  Printed in U.S.A.
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved