E5CSV-Q1T-F AC100-240

器件型号:E5CSV-Q1T-F AC100-240
器件类别:机电产品    工业自动化    控制器   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

控制器 Temp Controller

参数
产品属性属性值
制造商:Omron
产品种类:控制器
发货限制:Mouser目前不销售该产品。
RoHS:详细信息
模拟/数字:Digital
类型:Temperature Controller
显示器类型:7-Segment, 3.5 Digit
工作电源电压:100 VAC to 240 VAC
安装:Panel
大小:94 mm x 48 mm x 48 mm
特点:8-mode alarm output and sensor error detection
输出类型:Voltage
系列:E5CSV
商标:Omron Automation and Safety
产品类型:Controllers
工厂包装数量:1
子类别:Controllers
零件号别名:1385261 E5CSV-Q1TF-AC100-240 E5CSVQ1TFAC100240
单位重量:120 g

E5CSV-Q1T-F AC100-240器件文档内容

   Temperature Controllers

   E5CSV

Simple to Set and Operate 1/16 DIN Size

Controllers

•  Easy setting using internal DIP and rotary switches

•  ON/OFF or PID control (with on-demand auto-tuning)

   selectable

•  Clearly visible digital display with character height of 13.5 mm

•  Deviation indicator makes monitoring more effective

•  Multiple temperature sensor input (thermocouple/platinum

   resistance thermometer) models stocked; thermocouple

   input only and platinum RTD input only models available

•  Models with two alarms are ideal for temperature alarm

   applications                                                      • ° C or ° F field selectable

•  Setting change protection prohibits tampering                     • Black or white cases available to match panel aesthetics

•  Sampling rate (500 ms) and selectable control period (2 and       • RoHS compliant

   20 s) improves response                                           • Water-resistant front panel rated NEMA 4X/IP66

•  8-mode alarm output and sensor error detection                    • Compact: measures 48 H x 48 W x 78 D mm

•  “Input shift” function adjusts display to reflect known sensor    • Accuracy ±0.5% of value

   offsets

Model Number Structure

■ Model Number Legend

Models with Terminal Blocks

               1   2  3  4  5  6

1.  Output type                                                      4.  Power supply voltage

    R:      Relay                                                        Blank:  100 to 240 VAC

    Q:      Voltage for driving SSR                                      D:      24 VAC/VDC

2.  Number of alarms                                                 5.  Case color / Display scale

    Blank:No alarm                                                       Blank:  Black

    1:      1 alarm                                                      W:      Light gray

    2:      2 alarms                                                     F:      Scale marked in ° F            (Black  case  only)

3.  Input type                                                       6.  Power supply voltage

    T:      Thermocouple/platinum resistance thermometer                 AC100-240: 100 to 240 VAC

            (multi-input)                                                AC/DC24: 24 VAC/VDC

    KJ:     Thermocouple

    P:      Platinum resistance thermometer

Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations.

         Please refer to Ordering Information when ordering.

         Examples

         •  Voltage control output, without alarm, multi-input, light gray case: 115 VAC: E5CSV-QT-W AC100-240

         •  Relay control output, one alarm output, multi-input, black case: 24 VDC: E5CSV-R1TD AC/DC24

                                                                             Temperature Controllers E5CSV
Ordering Information

■ List of Models

   Size            Power      Number          Control output             TC/Pt multi-input         TC input               Pt input                   TC/Pt multi-input

                   supply     of alarm                                   Case color: Black         Case color:            Case color:                Case color: Black

                   voltage       points                                  Scale marked in ° C       Light gray             Light gray              Scale marked in ° F

                                                                                                   Scale marked in  °  C  Scale marked in ° C

1/16 DIN          100 to 240  0           Relay                          E5CSV-RT AC100-240                                                     E5CSV-RT-F AC100-240

48 × 48 × 78 mm   VAC                     Voltage   (for  driving  SSR)  E5CSV-QT AC100-240                                                     E5CSV-QT-F AC100-240

(W × H × D)

                              1           Relay                          E5CSV-R1T AC100-240       E5CSV-R1KJ-W           E5CSV-R1P-W           E5CSV-R1T-F AC100-240

                                          Voltage   (for  driving  SSR)  E5CSV-Q1T AC100-240       E5CSV-Q1KJ-W           E5CSV-Q1P-W           E5CSV-Q1T-F AC100-240

                              2           Relay                          E5CSV-R2T AC100-240                                                    E5CSV-R2T-F AC100-240

                              (See note)  Voltage   (for  driving  SSR)  E5CSV-Q2T AC100-240                                                    E5CSV-Q2T-F AC100-240

                  24 VAC/     0           Relay                          E5CSV-RTD AC/DC24

                  VDC                     Voltage   (for  driving  SSR)  E5CSV-QTD AC/DC24

                              1           Relay                          E5CSV-R1TD AC/DC24                                                     E5CSV-R1TD-F AC/DC24

                                          Voltage   (for  driving  SSR)  E5CSV-Q1TD AC/DC24                                                     E5CSV-Q1TD-F AC/DC24

                              2           Relay                          E5CSV-R2TD AC/DC24

                              (See note)  Voltage   (for  driving  SSR)  E5CSV-Q2TD AC/DC24

Note: Models with two alarm outputs       always use the upper           limit alarm mode for the  alarm 2 output.

■ Accessories (Order Separately)

Protective Cover

          Type                   Model

Hard Protective Cover       Y92A-48B

Terminal Cover

          Model

E53-COV10

Specifications

■ Ratings

Supply voltage                                      100 to 240 VAC, 50/60 Hz                                24 VAC/VDC, 50/60 Hz

Operating voltage range                             85% to 110% of rated supply voltage

Power consumption                                   5 VA                                                    3 VA/2 W

Sensor input                                        Thermocouple input type:                                                       K, J, L

                                                    Platinum resistance thermometer input type:                                    Pt100, JPt100

                                                    Multi-input (thermocouple/platinum resistance thermometer) type:               K, J, L, T, U, N, R, Pt100, JPt100

Control   Relay output                              SPST-NO, 250 VAC, 3A (resistive load)

output    Voltage output (for driving    the  SSR)  12 VDC, 21 mA (with short-circuit protection circuit)3

Control method                                      ON/OFF or 2-PID (with auto-tuning)

Alarm output                                        SPST-NO, 250 VAC, 1A (resistive load)

Setting method                                      Digital setting using front panel keys

Indication method                                   3.5 digit, 7-segment digital display (character height: 13.5 mm) and deviation indicators

Other functions                                     •  Setting change prohibit (key protection)

                                                    •  Input shift

                                                    •  Temperature unit change (° C/° F)

                                                    •  Direct/reverse operation

                                                    •  Temperature range, Sensor switching (K/J/L, Pt100/JPt100)

                                                    •  Switching is performed between a thermocouple and platinum      resistance  thermometer  for  multi-input  models.

                                                    •  Control period switching

                                                    •  8-mode alarm output

                                                    •  Sensor error detection

Ambient temperature                                 –10 to 55° C (with no condensation or icing)

Ambient humidity                                    25% to 85%

Storage temperature                                 –25 to 65° C (with no condensation or icing)

2                Temperature Controllers E5CSV
■ Characteristics

Setting accuracy                                             Thermocouple (See note 1.):                             (±0.5% of indication value or ±1° C, whichever is greater) ±1 digit max.

Indication accuracy                                          Platinum resistance thermometer (See note 2.):          (±0.5% of indication value or ±1° C, whichever is greater) ±1 digit max.

(ambient temperature of 23° C)

Influence of temperature                                     R thermocouple inputs:                                  (±1% of PV or ±10° C, whichever is greater) ±1 digit max.

Influence of voltage                                         Other thermocouple inputs:                              (±1% of PV or ±4° C, whichever is greater) ±1 digit max.

                                                             Platinum resistance thermometer inputs:                 (±1% of PV or ±2° C, whichever is greater) ±1 digit max.

Hysteresis (for ON/OFF control)                              0.2% FS (0.1% FS for multi-input (thermocouple/platinum resistance thermometer) models)

Proportional band (P)                                        1 to 999° C (automatic adjustment using auto-tuning/self-tuning)

Integral time (I)                                            1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning

Derivative time (D)                                          1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Alarm output range                                           Absolute-value alarm:            Same as the control range

                                                             Other:                           0% to 100% FS

                                                             Alarm hysteresis:                0.2° C or ° F (fixed)

Control period                                               2/20 s

Sampling period                                              500 ms

Insulation resistance                                        20 MΩ min. (at 500 VDC)

Dielectric strength                                          2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity

Vibration                                       Malfunction  10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

resistance                                      Destruction  10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions

Shock resistance                                Malfunction  100 m/s2 min., 3 times each in 6 directions

                                                Destruction  300 m/s2 min., 3 times each in 6 directions

Life expectancy                                 Electrical   100,000 operations min. (relay output models)

Weight                                                       Approx. 120 g (Controller only)

Degree of protection                                         Front panel: Equivalent to IP66; Rear case: IP20; Terminals: IP00

Memory protection                                            EEPROM (non-volatile memory) (number of writes: 1,000,000)

EMC                                                          EMI Radiated:                                   EN 55011 Group 1 Class A

                                                             EMI Conducted:                                  EN 55011 Group 1 Class A

                                                             ESD Immunity:                                   EN 61000-4-2:      4 kV contact discharge (level 2)

                                                                                                                                8 kV air discharge (level 3)

                                                             Radiated Electromagnetic Field Immunity:        EN 61000-4-3:      10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude       modulated) (level  3)

                                                                                                                                10 V/m (900 MHz pulse modulated)

                                                             Conducted Disturbance Immunity:                 EN 61000-4-6:      3 V (0.15 to 80 MHz) (level 2)

                                                             Noise Immunity (First Transient Burst Noise):   EN 61000-4-4

                                                             Burst Immunity:                                 2 kV power-line (level 3), 1 kV I/O signal-line (level 3)

                                                             Surge Immunity:                                 EN 61000-4-5:      Power line:                   Normal mode 1 kV;  Common mode 2      kV

                                                                                                                                Output line (relay output): Normal mode 1 kV;    Common mode 2      kV

                                                             Voltage Dip/Interrupting Immunity:              EN 61000-4-11 0.5 cycle, 100% (rated voltage)

Approved standards                                           UL 61010C-1 (listing)

                                                             CSA C22.2 No.1010-1

Conformed standards                                          EN 61326, EN 61010-1, IEC 61010-1

                                                             VDE 0106 Part 100 (finger protection), when the terminal cover is mounted.

Note: 1.                        The following exceptions apply to thermocouples.

                                • U, L:  ±2° C ±1 digit max.

                                • R:     ±3° C ±1 digit max. at 200° C or less

                         2.     The following exceptions apply to platinum resistance ther-

                                mometers.

                                Input set values 0, 1, 2, 3 for E5CSV: 0.5% FS ±1 digit max.

                                Input set value 1 for E5CSV: 0.5% FS ±1 digit max.

■ Electrical Life Expectancy Curve for Relays (Reference Values)

Life (× 104 operations)  500

                         300

                         100

                         50

                         30

                         10

                             5        E5CSV

                             3        250 VAC, 30 VDC

                                      (resistive load)

                                      cosφ = 1

                             1

                                0     1         2       3    4       5        6

                                                             Switching current (A)

                                                                                                                             Temperature Controllers E5CSV                                     3
■ Temperature Range

Thermocouple Input                              Models

                                   Input                                 K                                                J/L

                    Temperature                                                                      999

       901                         1,000

                    range          900

   78           2                  800

                3   (selected      700                                                   600

       6     4      using switch)  600                                       500                                                      500

          5                        500                            400                                                           400

                                   400                    300                                                        300

                                   300          200                                                          200

(Default        setting: 2)        200

                                   100

                                          0     0         0       0          0           0           0       0       0          0     0

                             Setting number     0         1       2          3           4           5       6       7          8     9       The shaded value indicates  the  default

                    Minimum setting unit                               1° C                                               1° C                setting status.

Platinum Resistance Thermometer                                                     Input Models

       901          Temperature    Input                                            JPt100/Pt100

   78           23  range          500                                                                       400                400

                    (selected      400                                                               300             300

       6     4      using switch)  300                                                   200                                          199.9

          5                        200          50        50.0    80         99.9

                                   100

(Default        setting: 3)                  0            0.0                0.0         0           0       0       0          0     0.0

                                   –100         –50               –20

                             Setting number     0         1       2          3           4           5       6       7          8     9       The shaded value indicates  the  default

                    Minimum setting unit        1° C      0.1° C  1° C      0.1° C                           1° C                     0.1° C  setting status.

Multi-input (Thermocouple/Platinum Resistance Thermometer)                                                                                    Models

• Using Thermocouple Sensors,                          Control    Mode Switch 5:                  OFF

                                   Input               K                 J               L                T          U          N     R

                                   1,700                                                                                              1,700

                    Temperature    1,600

       901          range          1,500

                                   1,400        1,300                                                                          1,300

   78           23  (selected      1,300

                    using switch)  1,200

       6  5  4                     1,100

                                   1,000                          850                    850

                                   900

                                   800

                                   700

(Default        setting: 0)        600

                                   500                                                               400             400

                                   400

                                   300                    199.9             199.9                            199.9

                                   200

                                   100

                                             0            0.0                0.0                             0.0                      0

                                   –100         –99               –99                    –99         –99             –99        –99

                             Setting number     0         1       2          3           4           5       6       7          8     9       The shaded value indicates  the  default

                    Minimum setting unit        1° C      0.1° C  1° C      0.1° C            1°  C          0.1° C            1° C           setting status.

• Using Platinum Resistance                     Thermometers,            Control Mode Switch 5: ON

                                   Input                          Pt100                                              JPt100

       901          Temperature    1,000        850

                    range          900

   78           23  (selected      800

                    using switch)  700

       6     4                     600                                                               500

          5                        500                                                   400                                          400

                                   400

(Default        setting: 0)        300                    199.9              200                             199.9              200

                                   200                            99                                                 99

                                   100

                                             0            0.0                0           0                   0.0                0     0

                                   –100         –99               –99                                –99             –99

                             Setting number     0         1       2          3           4           5       6       7          8     9       The shaded value indicates  the  default

                    Minimum setting unit        1° C      0.1° C                   1° C                      0.1° C            1° C           setting status.

4                   Temperature Controllers E5CSV
External  Connection Diagram

              Voltage output

              models                   Relay output                      Alarm output

              (See note 1.)                                  models

              Voltage output           Relay output

                                    1                        1       6

              12 VDC,

              21 mA

                                    2                        2       7   Alarm output 2 (See note 3.)

              A                                                          Alarm output 1 (See note 3.)

                                    3                        3       8

              B

                                    4                        4       9   100 to 240 VAC, 50/60 Hz

                                                                         (24 VAC/VDC)

              B                                                          (See note 2.)

                                    5                        5       10

              Platinum resistance      Thermocouple

              thermometer input                              input

                                    Thermocouple/

              platinum resistance thermometer multi-input

Note: 1.  The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a  grounding  thermocouple,  do  not

          connect output terminals 1 or 2 to ground. Otherwise, unwanted current paths will cause measurement       errors.

2.        Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity.

3.        The number of alarm outputs depends on the model.

Nomenclature

E5CSV Models with Terminal Blocks

                                                                                        Output indicator

              Deviation indicators                                                      Temperature display

              Mode indicators                                                           Alarm indicators

              Mode Key                                                                  Up Key

              Lock Release Key                                                          Down Key

                                                                         Temperature Controllers E5CSV                                            5
Operation

E5CSV

                   Deviation indicators                                                                                                        PV, SP, Alarm Value, Input Shift Display

    The  indicator lights when the PV is greater than                                                                                      The display switches each time the

    the SP and the               indicator lights when the PV is                                                                                Key is pressed.

    less than the SP. The             indicator (green) lights

    when the deviation is less than 1% FS (0.25% FS                                                                                             Output indicator

    for multi-input models). These indicators flash

    during ST (self-tuning)/AT (auto-tuning).                                                                                              Lights when the control output is ON.

                        Mode indicators

    The SP indicator lights when the setting                                                                                                    Alarm indicators

    temperature is being displayed. The ALM

    indicator lights when the alarm value 1 is                                                                                             ALM1 (Alarm 1): Lights when the alarm 1

    being displayed and flashes when the alarm                                                                                                  output is ON.

    value 2 is being displayed.                                                                                                            ALM2 (Alarm 2): Lights when the alarm 2

                                                                                                                                                output is ON.

                                 Mode Key

    When the power is turned ON, normally the                                                                                                   Up Key

    display will use the display items in the following                                                                                    Pressing the Up Key increases the

    order each time the Mode Key is pressed.                                                                                               SP/alarm value display. Keeping the Up

              Power ON                                                                                                                     Key pressed continues to increase the

                                                                                                                                           display value. When the internal protect

                                                                                                                                           switch is ON, press the Up Key while

                   PV                                                                                                                      holding down the Lock Release Key.

                        Press    the  Key.

                   SP

                        Press    the  Key.                                                                                                      Down Key

              Alarm value 1                                                                 Lock Release Key                               Pressing the Down Key decreases the

                        Press    the  Key.                                                                                                 SP/alarm value display. Keeping the Down

              Alarm value 2                                                   When the protect switch is ON, the set                       Key pressed continues to decrease the

                        Press    the  Key.                                    value can be changed by pressing the Up                      display value. When the internal protect

              Input shift value       This item is not displayed when         and Down Keys while holding down the                         switch is ON, press the Down Key while

                                      the Control Mode Switch 4 is OFF.

                        Press    the  Key.                                    Lock Release Key.                                            holding down the Lock Release Key.

Settings before Turning ON the Power

E5CSV

Remove the E5CSV from the case to make the settings.                                                  3.  When inserting the E5CSV, check to make sure that the sealing

1.  Insert the tool into the two tool insertion holes (one on the                           top  and      rubber is in place and push the E5CSV toward the rear case until

    one on the bottom) and release the hooks.                                                             it snaps into position. While pushing the E5CSV into place, push

                                                                                                          down on the hooks on the top and bottom surfaces of the rear case

                        Tool insertion hole                                                               so that the hooks are securely locked in place. Make sure that

                                                                                                          electronic components do not come into contact with the case.

                                                     Flat-blade screwdriver

                                                     (Unit: mm)                                                          Control mode switches  Alarm mode switch (See note 1.)

              (1)

                                                                                                              ON  ON                                             Temperature range switch

    (3)                                                                            20 min.

                                                                                                                      P  X  1  2  3  4  5   6

                                                                                                                               INIT switch

         (2)                                                             0.4  2.0                                              (See note 2.)

                   (1)                                                                                                         Protect switch

2.  Insert the tool in the gap between the front panel and rear case,

    and pull out the front panel slightly. Grip the front panel and pull

    out fully. Be sure not to impose excessive force on the panel.

                                                                                                      Note:   1.  The alarm mode switch is not provided on models without alarms.

                                                                                                                  Alarm 2 is always set to the upper limit in models with two alarms.

                                                                                                                  A setting switch is not provided for alarm 2.

                                                                                                              2.  The INIT switch is always OFF during normal operation.

6                  Temperature Controllers E5CSV
1. Sensor Type Specification

Select the number on the temperature range switch to change the                                          2.  If unit is changed to 1 degree when the SP and alarm value for

temperature range.                                                                                           the temperature range are displayed in 0.1-units from 0.0 to

                                                                                                             199.9 or 0.0 to 99.9, the values will be multiplied by 10 (e.g., 0.5

Thermocouple (The default is 2.)                                                                             becomes 5). If the unit is changed in the reverse direction, the

                                                                                                             values will be divided by 10. After changing the range, set the

           Input                            K                                   J/L                          SP and alarm value again.

                                                           999                                   •  Using Platinum Resistance Thermometers,

               1,000                                                                                Control Mode Switch 5: ON

               900

               800

               700                                    600                                                    Input                            Pt100                                 JPt100

SP             600                             500                                        500

range          500                     400                                           400                     1,000              850

               400              300                                        300                                    900

               300    200                                           200                                           800

               200                                                                                                700

               100                                                                                                600                                                 500

                0     0         0      0       0      0    0        0      0         0    0         SP            500

                                                                                                    range         400                                            400                                  400

Setting   number      0         1      2       3      4    5        6      7         8    9                       300                199.9            200                   199.9           200

• The control range is –10% to +10% FS for each temperature range.                                                200                            99                                    99

                                                                                                                  100

                                                                                                                  0                      0.0              0      0             0.0              0     0

Note: The input indication range is the range that can be displayed for the                                  –100               –99              –99                  –99              –99

       control range (–99 to 1999). If the input is within the control range                        Setting  number             0        1       2        3      4    5        6       7        8     9

       but exceeds the display range (–99 to 1999), values below –99 will

       be displayed as “[[[” and values above 1,999 will be displayed as                         •  The  control  range              is  –20° C       to     +20° C   of  the  input       temperature

       “]]].”                                                                                       range.

Platinum Resistance Thermometer                                                                  Note:   1.  The input indication range is the range that can be displayed for

                                                                                                             the control range (–99 to 1999). If the input is within the control

(The default is 3.)                                                                                          range but exceeds the display range (–99 to 1999), values be-

                                                                                                             low –99 will be displayed as “[[[” and values above 1,999 will

           Input                                      JPt100/Pt100                                           be displayed as “]]].”

               500                                                                                       2.  If unit is changed to 1 degree when the SP and alarm value for

               400                                                  400              400                     the temperature range are displayed in 0.1-units from 0.0 to

SP             300                                         300             300                               199.9 or 0.0 to 99.9, the values will be multiplied by 10 (e.g., 0.5

               200                                    200                                 199.9              becomes 5). If the unit is changed in the reverse direction, the

range          100    50        50.0   80      99.9

                0               0.0            0.0    0    0        0      0         0    0.0                values will be divided by 10. After changing the range, set the

               –100   –50              –20                                                                   SP and alarm value again.

Setting number        0         1      2       3      4    5        6      7         8    9      Mode Key Display Order

• The control range is –10% to +10% FS for each temperature range.

Note:  1.  The input indication range is the range that can be displayed for                                 Power ON                         •  If the SP falls outside the temperature range

           the control range (–99 to 1999). If the input is within the control                                                                   when the temperature range is changed, the

           range but exceeds the display range (–99 to 1999), values be-                                                                         SP   will   be  displayed  first.  The     SP  will  be

           low –99 will be displayed as “[[[” and values above 1,999 will                                                                        changed     automatically     either  to   the    mini-

           be displayed as “]]].”                                                                            PV                                  mum value or the maximum value, which-

                                                                                                                                                 ever is nearest.

       2.  If the unit is changed to 1 degree when the SP and alarm value                                    Press the               Key.     •  If the alarm value falls outside the tempera-

           for the temperature range are displayed in 0.1-units from 0.0 to                                  SP                                  ture range when the temperature range is

           199.9 or 0.0 to 99.9, the values will be multiplied by 10 (e.g., 0.5                              Press the               Key.        changed, the alarm value will be displayed

           becomes 5). If the unit is changed in the reverse direction, the                                                                      first. The alarm value will be changed auto-

           values will be divided by 10. After changing the range, set the                                   Alarm value 1                       matically to the maximum value in the new

           SP and alarm value again.                                                                         Press the               Key.        temperature range.

       3.  The temperature range for setting numbers 5 and 6 are the                                         Alarm value 2

           same as for 7 and 8, respectively.

                                                                                                             Press the               Key.

Multi-input (Thermocouple/Platinum                                                                           Input shift value

Resistance Thermometer) Models                                                                               Press the               Key.

• Using Thermocouple Sensors, Control Mode Switch 5: OFF

           Input             K              J         L         T          U         N    R

               1,700                                                                      1,700

               1,600

               1,500

               1,400  1,300                                                     1,300

               1,300

               1,200

               1,100

               1,000                   850            850

SP             900

range          800

               700

               600

               500                                         400             400

               400

               300              199.9          199.9                199.9

               200

               100

                0               0.0            0.0                  0.0                   0

               –100   –99              –99            –99  –99             –99       –99

Setting   number      0         1      2       3      4    5        6      7         8    9

• The control range is –20° C to +20° C of the input temperature range.

Note: 1.   The input indication range is the range that can be displayed for

           the control range (–99 to 1999). If the input is within the control

           range but exceeds the display range (–99 to 1999), values be-

           low –99 will be displayed as “[[[” and values above 1,999 will

           be displayed as “]]].”

                                                                                                             Temperature Controllers E5CSV                                                            7
2. Operation Settings                                                              3. Alarm Modes

                                 ON                                                Select the number of the alarm mode switch                    901      when changing

Use the control mode switches (                              ) to change the con-                                                            78       23

                                 1   2  3     4  5     6                                                                                         456

trol mode. (All switches are OFF for the default settings.)                        the alarm mode. (The default is 2).

                                        ON                                         Set          Alarm type              Alarm output      operation

                                                                                   value

                                                                                   0, 9         Alarm function OFF      OFF

                                           1        2        3     4  5    6       1            Upper- and lower-                         X               X

                                                                                                limit                        ON

Function selection                   1        2           3     4     5    6                                                 OFF                 SP

ON/OFF   PID control                 ON                                            2            Upper-limit                                               X

PID                                                                                                                          ON

                                                                                                                        OFF                      SP

         ON/OFF control              OFF

Control  2s                                                                        3            Lower-limit                               X

                                                 ON                                                                          ON

period   20 s                                 OFF                                                                       OFF                      SP

Direct/  Direct operation                                                          4            Upper- and lower-                         X               X

reverse  (cooling)                                        ON                                    limit range                  ON

opera-                                                                                                                       OFF                 SP

tion     Reverse operation                                OFF                      5            Upper- and lower-                         X               X

         (heating)                                                                                                           ON

Input    Enabled                                                ON                              limit with standby se-       OFF

shift                                                                                           quence (See note 2.)                             SP

display  Disabled                                               OFF                6            Upper-limit with                                          X

                                                                                                standby sequence             ON

Temper-  Thermo-      K, L                                            ON                        (See note 2.)                OFF                 SP

ature    couple       K, J                                            OFF

Sensor                                                                             7            Lower-limit with                          X

selec-                                                                                          standby sequence             ON

tion     Platinum     Pt100                                           ON                        (See note 2.)                OFF

         resis-                                                                                                                                  SP

         tance        JPt100                                                       8            Absolute-value up-                                        Y

         thermom-                                                     OFF                       per-limit                    ON

         eter                                                                                                                OFF                 0

         Multi-       Platinum

         input        resis-                                                       Note: 1.     No alarm. The alarm value (alarm operation display) will not

         (thermo-     tance                                           ON                        be displayed when the setting is 0 or 9 even if the selection

         couple/      ther-                                                                     key is pressed.

         platinum     mometer                                                                   Alarm Setting Range

         resis-       input                                                                     X: 0 to FS (full scale); Y: Within temperature range

         tance        Thermo-                                                                   The value of X is the deviation setting for the SP (set point).

         thermom-     couple                                          OFF

         eter)        input                                                                2.   Standby Sequence Function (The standby sequence oper-

                                                                                                ates when the power is turned ON.)

Temper-  °F                                                                ON      Rising Temperature                        Dropping Temperature

ature    °C

unit                                                                       OFF     Upper-limit

Note: The previous name Pt100 has been changed to JPt100 in ac-                    alarm                                     Upper-limit

                                                                                           SP                                alarm

       cordance with revisions to JIS. The previous name J-DIN has                                                                   SP

       been changed to L in accordance with revisions to DIN stan-                 Lower-limit

       dards.                                                                      alarm                                     Lower-limit

                                                                                   Alarm   ON                                alarm

                                                                                   output  OFF                               Alarm    ON

                                                                                                                             output  OFF

Note: Turn OFF the power before changing the DIP switch settings on the E5CSV. Each of the switch settings will be enabled after the power is

        turned ON.

For details on the position of the temperature range switch, control mode switches, and alarm mode switch, refer to page 6.

8              Temperature Controllers E5CSV
4. Using the Control Mode Switches

(1) Using ON/OFF Control and PID Control

ON/OFF Control

The control mode is set to ON/OFF control as the default setting.              To  perform  cooling control of freezers,                  etc., turn  ON  switch    3.

                    ON                                                                                    ON

                    1        2      3      4        5     6

                                                                                                          1       2           3           4     5     6

                Switch 1 OFF: ON/OFF control

            Control output      ON                                                               Control  output     ON

                             OFF                                                                                  OFF

                                                 SP                                                                                          SP

PID Control

Turn ON switch 1 to use PID control.

                ON

                1       2       3       4        5        6

            Switch 1 ON: PID control

1.  Set the control period.                                                    2.  Set direct/reverse operation for the output.

    Performing Control via Relay Output, External            Relay,  or  Con-      Performing Heating Control for Heaters

    ductor                                                                         Switch 3: OFF

    Switch 2: OFF (control period: 20 s)

                                                                                                 ON

            ON

                                                                                                 1   2        3            4     5           6

             1      2        3      4         5        6                                                                                           Output level

    Control output ON                                                                       100%

                   OFF                                                                           0%

                                        20 s                                                                                     SP

    Quick Control Response Using an SSR                                            Performing Cooling Control for Freezers

    Switch 2: ON (control period: 2 s)                                             Switch 3: ON

            ON                                                                                   ON

             1      2        3      4         5        6                                         1   2        3            4     5           6

    Control output ON                                                                                                                              Output level

                   OFF                                                                      100%

                                2s                                                               0%

                                                                                                                                 SP

ST (Self-tuning) Features                                                Executing AT (Auto-tuning)

ST (self-tuning) is a function that finds PID constants by               AT (auto-tuning) is executed by pressing the U Up and D Down Keys for at

using step response tuning (SRT) when Controller oper-                   least 2 s while the PV is displayed. The deviation indicators flash during auto-

ation begins or when the set point is changed. Once the                  tuning (AT) execution. AT will be cancelled by performing the same operation

PID constants have been calculated, ST is not executed                   that AT is executing during AT operation. Flashing stops when AT is completed.

when the next control operation is started as long as the                      AT execution

set point remains unchanged. When the ST function is

in operation, be sure to turn ON the power supply of the                                                                   U     D

load connected to the control output simultaneously with                                                                   Press for

or before starting Controller operation.                                                                                   at least 2 s.  AT execution in progress

                                                                                   AT cancelled

                                                                                                                           U     D

                                                                                                                           Press for

                                                                                                 AT execution in progress  at least 2 s.

                                                                         Note: One of the deviation indicators (▲■▼) will flash.

                                                                                   Temperature Controllers E5CSV                                                        9
(2) Using the E5CSV in Devices for Fahrenheit-scale Users

(Displaying in ° F)

Turn ON switch 6 to display temperatures in ° F.

                     ON

                        1   2      3  4  5            6

Temperature Range for ° F

The temperature is set to ° F using the same temperature range switch as ° C.

Thermocouple                          Platinum Resistance                      Multi-input (Thermocouple/               Multi-input (Thermocouple/

                                      Thermometer                              Platinum Resistance                      Platinum Resistance

                                                                               Thermometer)                             Thermometer)

                                                                               Control mode switch 5: OFF               Control mode switch 5: ON

Set-          °      F                   Set-             °F                   Set-                 °F                    Set-           °F

ting                                     ting                                  ting                                       ting

0     K              0  to  200       0           JPt100  –50  to  50          0     K              –99 to 1999         0        Pt100   –99 to 1500

1                    0  to  300       1           or      0.0  to  50.0        1                    0.0 to 199.9        1                0.0 to 199.9

2                    0  to  400       2           Pt100   –20  to  80          2     J              –99 to 1500         2                –99 to 99

3                    0  to  500       3                   0.0  to  99.9        3                    0.0 to 199.9        3                       0 to 200

4                    0  to  600       4                   0    to  200         4     L              –99 to 1500         4                       0 to 400

5                    0  to  999       5                   0    to  300         5     T              –99 to 700          5        JPt100  –99 to 900

6     J/L            0  to  999       6                   0    to  400         6                    0.0 to 199.9        6                0.0 to 199.9

7                    0  to  300       7                   0    to  600         7     U              –99 to 700          7                –99 to 99

8                    0  to  400       8                   0    to  800         8     N              –99 to 1999         8                       0 to 200

9                    0  to  500       9                   0.0  to  199.9       9     R              0 to 1999           9                       0 to 400

Note: The control range for a thermocouple input or platinum resistance thermometer input is –10% to +10% FS            for each temperature range.

      The control range for multi-input (thermocouple/platinum resistance thermometer) models is –40 to +40° F          of each temperature range.

Using K, L/Pt100 Thermometers

Turn ON switch 5 when using K, L/Pt100 Thermometers.

                     ON

                        1   2      3  4  5            6

Note: The previous name J-DIN has been changed to L in accordance with revisions to DIN standards.

(3) Setting Input Shift

Turn ON switch 4, and after turning ON the power, press the Mode               Shift Example

Key until h0 (indicates input shift of 0) is displayed. Press the Up and

Down Keys to set the shift value.                                              Input shift display      Measured temperature             Temperature

                                                                                                                                         display

                     ON                                                           h0 (no shift)                   100° C                 100° C

                                                                                  h9 (+9° C shift)                100° C                 109° C

                                                                                  l9 (–9° C shift)                100° C                        91° C

                        1   2      3  4  5            6

                                                                               Note: When control mode switch 4 is turned OFF (no input shift dis-

                                                                                     play), the input shift is not displayed but the shift value is en-

                                                                                     abled. To disable input shift, set the input shift value to h0. The

                                                                                     shift range depends on the setting unit.

                                                                                     Setting unit                 1° C                  0.1° C

                                                                                     Compensation range           –99 to +99° C  –9.9 to +9.9° C

                                                                                     Input shift display          L99 to H99     L9.9 to H9.9

10         Temperature Controllers E5CSV
5. Protect Switch

                                 ON

    Protect Switch

                                 P   X  1     2  3  4  5   6

When the protect switch is ON, Up Key and Down Key operations are prohibited to prevent setting mistakes.

Installation

• All models in the E5CSV Series conform to DIN 43700 standards.

• The recommended panel thickness is 1 to 4 mm.

• Be sure to mount the E5CSV horizontally.

Mounting the E5CSV

1.  For waterproof mounting, waterproof packing must be installed on the Controller. Waterproofing is not possible when group mounting several

    Controllers.

2.  Insert the E5CSV into the mounting hole in the panel.

3.  Push the adapter from the terminals up to the panel, and temporarily fasten the E5CSV.

4.  Tighten the two fastening screws on the adapter. Alternately tighten the two screws little by little to maintain a balance. Tighten the screws to a

    torque of 0.29 to 0.39 N·m.

                                     Adapter     Tightening screw

    Waterproof packing           Panel           Tightening screw

                                                                   Temperature Controllers E5CSV                                                         11
Error Displays and Causes

In addition to the alarm indicator, errors notification is provided on the display. Be sure to remove the cause of the error promptly.

Display status                                 Cause                                                                     Control output

PV displayed as   The process value is higher than the control temperature range (overflow).                  Heating control (reverse operation): OFF

fff                                                                                                           Cooling control (direct operation): ON

PV displayed as   The process value is lower than the control temperature range (underflow).                  Heating control (reverse operation): ON

---                                                                                                           Cooling control (direct operation): OFF

fff flashing      (1)Thermocouple models and platinum resistance thermometer models:                          OFF

                         The process value is higher than the overflow temperature, or a Sensor error has

                         occurred.

                  (2)Multi-input (Thermocouple/platinum resistance thermometer) models:

                         The process value is higher than the control temperature range or a Sensor error

                         has occurred.

--- flashing      (1)Thermocouple and platinum resistance thermometer input:                                  OFF

                         The process value is lower than the underflow temperature, or a Sensor error has

                         occurred.

                  (2)Thermocouples: The polarity is reversed.

                  (3)Multi-input (Thermocouple/platinum resistance thermometer) models:

                         The process value is lower than the control temperature range or a Sensor error has

                         occurred.

e11 is            A memory error (E11) has occurred. Turn the power ON again. If the display remains          The control outputs and alarm outputs

displayed         the same, the Controller must be repaired.                                                  turn OFF.

Note: In models with an alarm, fff appears or flashes on the display to indicate that the temperature has exceeded the maximum display tem-

     perature and the output is set according to the alarm mode. In the same way, --- appears or flashes on the display to indicate that the

     temperature has exceeded the minimum display temperature and the output is set according to the alarm mode.

Sensor Error Displays and Causes

■ Thermocouple

                      Status                   Display                      Control output

Burnout                                        fff flashing    OFF

Note: The room temperature is displayed if an  input short-circuit occurs.

■ Platinum Resistance                          Thermometer

                      Status                   Display                      Control  output

Burnout                                        fff flashing    OFF

                                        3

                                        4

                                        5

                                        3

                                        4

                                        5

                                               --- flashing    OFF

                                        3

                                        4

                                        5

               2  or  3  wires  disconnected   fff flashing    OFF

Short-circuit                                  --- flashing    OFF

Note: The resistance value for platinum resistance thermometers is 100 Ω at 0° C and 140 Ω at 100° C.

12             Temperature Controllers E5CSV
Comparison with E5CS-X

■ Model Number Legend

                        Previous model                                                                     E5CSV

E5CS-@@@X                                                            E5CSV-@@@@-@

   1             2  3                                                            1  2    3   4   5

   Classification          Symbol                 Meaning                        Classification         Symbol                   Meaning

1  Control output       R          Relay: SPDT (single-pole,         1           Control output     R             Relay: SPST-NO (single-pole,

                                   double-throw)                                                                  single-throw, normally open)

                        Q          Voltage                                                          Q             Voltage

2  Alarm output         Blank      No alarms                         2           Alarm output       Blank         No alarms

                        1          One alarm                                                        1             One alarm

3  Input type           KJ         Thermocouple (K, J)                                              2             Two alarms

                        P          Platinum resistance thermome-     3           Input type         T             Multi-input (thermocouple/platinum

                                   ter (Pt100, JPt100)                                                            resistance thermometer) models

   Terminal             X          Model with terminal block                                        KJ            Thermocouple (K, J)

   appearance                                                                                       P             Platinum resistance thermometer

                                                                                                                  (Pt100, JPt100)

Main Differences                                                     4           Supply             Blank         100 to 240 VAC

Terminal block models use the model number E5CSV.                                specifications     D             24 VAC/VDC

The suffix “D” is added to models with a supply voltage of           5           Case color         Blank         Black

24 VAC/VDC.                                                                                         W             Light gray

The suffix “W” is added to models with a light gray case color.                                     F             Scale marked in F° (Black case only)

■ Display

                            Previous model                                                                 E5CSV

                    SP  AL                        AL

The display digits can be increased up to 1,999.

The ALM2 display has been added.

The display “ON” has changed to “OUT” and “AL” has changed to “ALM.”

■ Functions

The control outputs for relay outputs have been changed from SPDT (single-pole,     double-throw)   to  SPST-NO   (single-pole,  single-throw,  normally

open) contacts.

The control method has been changed to 2-PID control.

An auto-tuning (AT) function has been added.

The deviation display flashes during self-tuning (ST) and auto-tuning (AT).

The control calculation period has been improved from 2 s to 0.5 s.

■ External Dimensions

The depth has been shortened from 100 mm to 76 mm.

                                                                                    Temperature Controllers E5CSV                                     13
■ Terminal Arrangement

• The terminal arrangement has changed from a horizontal to            vertical  configuration.

                        Previous model                                                                                E5CSV

                             12 VDC,          100 to 240 VAC,                                    Voltage output       Relay output

                                 20 mA        50/60 Hz or 24 VAC/VDC,

                                              50/60 Hz

                             7          8     SOURCE                                                      1           1             6

           250 VAC, 3 A                                                                          12 VDC,

           (Resistive load)                                                                      21 mA

                     6       7          8     9         10                                                2           2             7        Alarm output 2

                                                                                                 A                                           Alarm output 1

                                                                                                          3           3             8

                                                                                                 B

                     1       2          3     4         5                                                 4           4             9        100 to 240 VAC,

    Thermocouple                              ALARM                                                                                          50/60 Hz

    input                                     250 VAC, 1 A                                       B                                           (24 VAC/VDC)

                                              (Resistive load)                                            5           5             10

                  A             B          B

                                                                                                 Platinum resistance  Thermocouple

           Platinum resistance                                                                   thermometer input    input

           thermometer input

                                                                                 Multi-input (thermocouple/platinum resistance thermometer)

■ DIP Switch and Rotary Switch Setting Methods

No change from previous models.

14  Temperature Controllers E5CSV
Dimensions

Note: All units are in millimeters unless otherwise      indicated.

■ Controller

E5CSV                                                                                                                               Panel        Cutout Dimensions

                                                                               84

                                       48×48                   6               78                                                   45+00.6                      L

                                                                                                                           45+00.6               45+00.6

                                                                                                  44.8×44.8

                                                                                                                 60  min.                            L = (48 × N−2.5)+01

                                                                                                                                                     Mounting side-by-side

                                                                                                                                                     (group mounting of N Controllers)

                                                               Note:  Terminals cannot be         removed.

E5CSV + Adapter for Flush Mounting

(Provided)                                                                                             Panel         Y92F-30        Adapter for  flush mounting

                                                                      Adapter for flush mounting

                                                           58

                                                                                                                           Tightening

                                                                          48                                               screws

                                                                                                  7.5                      76.5

                                                                                                       Note: 1.  The recommended panel thickness is 1 to 4 mm.

                                                                                                             2.  Group mounting is possible in one direction only.

Hard Protective Cover                                                              Terminal Cover

The   Y92A-48B  Protective      Cover  (hard  type)  is  available   for  the      E53-COV10

following applications.                                                                                                                          48

• To protect the set from dust and dirt.

• To  prevent  the  panel  from     being  accidentally  touched     causing

displacement of set values.                                                                                                         48.8

• To provide effective protection against water droplets.

                            °C

                                                                                                                                    22

                           92A-48B

                                                                                                                                    9.1

                                                                                                  Temperature Controllers E5CSV                                             15
Precautions

    !Caution                                                   Note: 1.    A SELV circuit is one separated from the power supply with

                                                                           double insulation or reinforced insulation, that does not ex-

                                                                           ceed 30 V r.m.s. and 42.4 V peak or 60 VDC.

Do not touch the terminals while power is being supplied.             2.   A class 2 power supply is one tested and certified by UL as

Doing so may occasionally result in minor injury due to                    having the current and voltage of the secondary output re-

electric shock.                                                            stricted to specific levels.

Do not allow pieces of metal, wire clippings, or fine          ■ Precautions for Safe Use

metallic shavings or filings from installation to enter the

product. Doing so may occasionally result in electric          Be sure to observe the following precautions to prevent operation fail-

shock, fire, or malfunction.                                   ure, malfunction, or adverse affects on the performance and func-

Do not use the product where subject to flammable or           tions  of   the  product.    Not  doing   so      may   occasionally  result  in

explosive gas. Otherwise, minor injury from explosion          unexpected events.

may occasionally occur.                                        1.  The product is designed for indoor use only. Do not use the prod-

Never disassemble, modify, or repair the product or touch          uct outdoors or in any of the following locations.

any of the internal parts. Minor electric shock, fire, or          • Places directly subject to heat radiated from heating equipment.

malfunction may occasionally occur.                                • Places subject to splashing liquid or oil atmosphere.

CAUTION - Risk of Fire and Electric Shock                          • Places subject to direct sunlight.

a) This product is UL listed as Open Type Process                  • Places subject to dust or corrosive gas (in particular, sulfide gas

    Control Equipment. It must be mounted in an                       and ammonia gas).

    enclosure that does not allow fire to escape externally.       • Places subject to intense temperature change.

b) More than one disconnect switch may be required to              • Places subject to icing and condensation.

    de-energize the equipment before servicing the

    product.                                                       • Places subject to vibration and large shocks.

c) Signal inputs are SELV, limited energy. (See note 1.)       2.  Use    and   store  the  product      within  the   rated  temperature  and

d) Caution: To reduce the risk of fire or electric shock, do       humidity ranges.

              not interconnect the outputs of different Class      Group-mounting two or more Temperature Controllers, or mount-

              2 circuits. (See note 2.)                            ing Temperature Controllers above each other may cause heat to

If the output relays are used past their life expectancy,          build up inside the Temperature Controllers, which will shorten

contact fusing or burning may occasionally occur. Always           their service life. In such a case, use forced cooling by fans or

consider the application conditions and use the output             other means of air ventilation to cool down the Temperature Con-

relays within their rated load and electrical life                 trollers.

expectancy. The life expectancy of output relays varies        3.  To allow heat to escape, do not block the area around the product.

considerably with the output load and switching                    Do not block the ventilation holes on the product.

conditions.                                                    4.  Use the specified size (M3.5, width of 7.2 mm or less) crimped

Loose screws may occasionally result in fire.                      terminals for wiring. To connect bare wires to the terminal block,

Tighten terminal screws to the specified torque of 0.74 to         use   copper  braided    or   solid   wires   with  a  gage  of   AWG24   to

0.90 N·m.                                                          AWG18 (equal to a cross-sectional area of 0.205 to 0.832 mm2).

                                                                   (The stripping length is 5 to 6 mm.) Up to two wires of the same

Unexpected operation may result in equipment damage                size and type, or two crimp terminals can be inserted into a single

or accidents if the settings are not appropriate for the           terminal.

controlled system. Set the Temperature Controller as           5.  Be sure to wire properly with correct polarity of terminals. Do not

follows:                                                           wire any of the I/O terminals incorrectly.

• Set the parameters of the Temperature Controller so          6.  Do not wire the terminals that are not used.

that they are appropriate for the controlled system.           7.  The voltage output (control output) is not electrically isolated from

• Turn the power supply to the Temperature Controller              the internal circuits. When using a grounded temperature sensor,

OFF before changing any switch setting. Switch settings            do not connect any of the control output terminals to ground. Oth-

are read only when the power supply is turned ON.                  erwise unwanted current paths will cause measurement errors.

• Make sure that the INIT switch in the control mode           8.  To avoid inductive noise, keep the wiring for the Temperature Con-

switches is turned OFF before operating the                        troller's terminal block away from power cables carrying high volt-

Temperature Controller.                                            ages or large currents. Also, do not wire power lines together with

A malfunction in the Temperature Controller may                    or parallel to Temperature Controller wiring. Using shielded cables

occasionally make control operations impossible or                 and using separate conduits or ducts is recommended.

prevent alarm outputs, resulting in property damage.               Attach a surge suppressor or noise filter to peripheral devices that

To maintain safety in the event of malfunction of the              generate     noise  (in  particular,  motors,      transformers,  solenoids,

Temperature Controller, take appropriate safety                    magnetic coils or other equipment that have an inductance com-

measures, such as installing a monitoring device on a              ponent).

separate line.                                                     When a noise filter is used at the power supply, first check the

Faulty terminal contact or decreased waterproofing                 voltage or current, and attach the noise filter as close as possible

capability may result in a fire or equipment malfunction.          to the temperature controller.

When inserting the Temperature Controller into the rear            Allow as much space as possible between the Temperature Con-

case after setting the switches, check the watertight              troller and devices that generate powerful high frequencies (high-

packing and make sure that the top and bottom hooks are            frequency    welders,    high-frequency       sewing   machines,  etc.)   or

locked securely in place.                                          surge.

16               Temperature Controllers E5CSV
9.  Use the product within the rated load and power supply.                ■ Precautions for Correct Use

10.Use a switch, relay, or other contact so that the power supply volt-

    age reaches the rated voltage within 2 seconds. If the applied

    voltage is increased gradually, the power supply may not be reset      Service Life

    or malfunctions may occur.

11.When using PID operation (self-tuning), turn ON the power supply        Use the Temperature Controller within the following temperature and

    to the load (e.g., heater) at the same time or before turning the      humidity ranges:

    power supply to the Temperature Controller ON. If power is turned      Temperature:        –10 to 55° C (with no icing or condensation)

    ON for the Temperature Controller before turning ON power sup-         Humidity:           25% to 85%

    ply to the load, self-tuning will not be performed properly and opti-

    mum control will not be achieved.                                      If the Controller is installed inside a control board, the ambient tem-

12.Design the system (e.g., control panel) to allow for the 2 seconds      perature  must  be  kept  to  under  55° C,  including  the  temperature

    of delay required for the Temperature Controller's output to stabi-    around the Controller.

    lize after the power is turned ON.                                     The service life of electronic devices like Temperature Controllers is

13.A switch or circuit breaker should be provided close to this unit.      determined not only by the number of times the relay is switched but

    The switch or circuit breaker should be within easy reach of the       also by the service life of internal electronic components. Component

    operator, and must be marked as a disconnecting means for this         service life is affected by the ambient temperature: the higher the

    unit.                                                                  temperature, the shorter the service life and, the lower the tempera-

14.Approximately 30 minutes is required for the correct temperature        ture, the longer the service life. Therefore, the service life can be

    to be displayed after turning the power supply to the Temperature      extended by lowering the temperature of the Temperature Controller.

    Controller ON. Turn the power supply ON at least 30 minutes prior      When two or more Temperature Controllers are mounted horizontally

    to starting control operations.                                        close to each other or vertically next to one another, the internal tem-

15.Be sure that the platinum resistance thermometer type and the           perature will increase due to heat radiated by the Temperature Con-

    input type set on the Temperature Controller are the same.             trollers and the service life will decrease. In such a case, use forced

16.When extending the thermocouple lead wires, always use com-             cooling by fans or other means of air ventilation to cool down the

    pensating conductors suitable for the type of thermocouple. Do         Temperature Controllers. When providing forced cooling, however, be

    not extend the lead wires on a platinum resistance thermometer.        careful not to cool down the terminals sections alone to avoid mea-

    Use only low-resistance wire (5 Ω max. per line) for lead wires and    surement errors.

    make sure that the resistance is the same for all three wires.

17.When drawing out the Temperature Controller from the case, do           Measurement Accuracy

    not apply force that would deform or alter the Temperature Con-

    troller.                                                               When extending or connecting the thermocouple lead wire, be sure

18.When drawing out the Temperature Controller from the case to            to use compensating wires that match the thermocouple type. Do not

    replace the Temperature Controller, check the status of the termi-     extend the lead wire of the platinum resistance thermometer. If the

    nals. If corroded terminals are used, contact faults with the termi-   lead wire of the platinum resistance thermometer must be extended,

    nals      may  cause   the  temperature  inside  the      Temperature  be sure to use wires that have low resistance and keep the resis-

    Controller to increase, possibly resulting in fire. If the terminals   tance of the three lead wires the same.

    are corroded, replace the rear case as well.                           Mount the Temperature Controller so that it is horizontally level.

19.When drawing out the Temperature Controller from the case, turn         If the measurement accuracy is low, check whether the input shift

    the power supply OFF first, and absolutely do not touch the termi-     has been set correctly.

    nals   or  electronic  components   or  apply  shock  to  them.  When

    inserting the Temperature Controller, do not allow the electronic      Waterproofing

    components to come into contact with the case.

20.Static electricity may damage internal components. Always touch         The degree of protection is as shown below. Sections without any

    grounded metal to discharge any static electricity before handling     specification on their degree of protection or those with IP@0 are not

    the Temperature Controller. When drawing out the Temperature           waterproof.

    Controller from the case, do not touch the electronic components

    or patterns on the board with your hand. Hold the Temperature          Front panel: IP66, rear case: IP20, terminals: IP00

    Controller by the edge of the front panel when handling it.

21.Do not use paint thinner or similar chemical to clean with. Use

    standard grade alcohol.

22.Use tools when separating parts for disposal. Contact with the

    sharp internal parts may cause injury.

                                                                                     Temperature Controllers E5CSV                             17
Warranty and Application Considerations

                                 Read and Understand this Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you

have any questions or comments.

                                 Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or

other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,

MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER

ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET

THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR

IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,

OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON

CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE

PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,

INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE

MODIFICATION OR REPAIR.

                                 Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of

products in the customer's application or use of the products.

Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will

be used.

Know and observe all prohibitions of use applicable to this product.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT

ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON

PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR

SYSTEM.

                                                        Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a

warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application

requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with

your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

18        Temperature Controllers E5CSV
Terms and Conditions of Sale

1.   Offer; Acceptance. These terms and conditions (these "Terms") are deemed                                ITY    OR    FITNESS    FOR     A   PARTICULAR       PURPOSE            OF  THE    PRODUCTS.

     part of all quotes, agreements, purchase orders, acknowledgments, price lists,                          BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

     catalogs, manuals, brochures and other documents, whether electronic or in                              PRODUCTS         WILL     SUITABLY       MEET     THE       REQUIREMENTS                OF   THEIR

     writing, relating to the sale of products or services (collectively, the "Products")                    INTENDED USE. Omron further disclaims all warranties and responsibility of

     by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron                                  any type for claims or expenses based on infringement by the Products or oth-

     objects to any terms or conditions proposed in Buyer’s purchase order or other                          erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-

     documents which are inconsistent with, or in addition to, these Terms.                                  gation   hereunder      shall  be,  at  Omron’s   election,     to  (i)  replace        (in  the  form

2.   Prices; Payment Terms. All prices stated are current, subject to change with-                           originally     shipped  with   Buyer    responsible    for  labor   charges        for  removal   or

     out notice by Omron. Omron reserves the right to increase or decrease prices                            replacement thereof) the non-complying Product, (ii) repair the non-complying

     on any unshipped portions of outstanding orders. Payments for Products are                              Product, or (iii) repay or credit Buyer an amount equal to the purchase price of

     due net 30 days unless otherwise stated in the invoice.                                                 the non-complying Product; provided that in no event shall Omron be responsi-

3.   Discounts. Cash discounts, if any, will apply only on the net amount of invoices                        ble for warranty, repair, indemnity or any other claims or expenses regarding

     sent to Buyer after deducting transportation charges, taxes and duties, and will                        the Products unless Omron’s analysis confirms that the Products were prop-

     be allowed only if (i) the invoice is paid according to Omron’s payment terms                           erly handled, stored, installed and maintained and not subject to contamina-

     and (ii) Buyer has no past due amounts.                                                                 tion, abuse, misuse or inappropriate modification. Return of any Products by

4.   Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or                           Buyer must be approved in writing by Omron before shipment. Omron Compa-

     the maximum legal rate, whichever is less, on any balance not paid within the                           nies shall not be liable for the suitability or unsuitability or the results from the

     stated terms.                                                                                           use of Products in combination with any electrical or electronic components,

5.   Orders. Omron will accept no order less than $200 net billing.                                          circuits, system assemblies or any other materials or substances or environ-

6.   Governmental Approvals. Buyer shall be responsible for, and shall bear all                              ments. Any advice, recommendations or information given orally or in writing,

     costs involved in, obtaining any government approvals required for the impor-                           are not to be construed as an amendment or addition to the above warranty.

     tation or sale of the Products.                                                                         See http://www.omron247.com or contact your Omron representative for pub-

7.   Taxes. All taxes, duties and other governmental charges (other than general                             lished information.

     real property and income taxes), including any interest or penalties thereon,                      14.  Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE

     imposed directly or indirectly on Omron or required to be collected directly or                         FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

     indirectly by Omron for the manufacture, production, sale, delivery, importa-                           LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY

     tion, consumption or use of the Products sold hereunder (including customs                              WAY     CONNECTED         WITH      THE  PRODUCTS,          WHETHER         SUCH        CLAIM     IS

     duties and sales, excise, use, turnover and license taxes) shall be charged to                          BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

     and remitted by Buyer to Omron.                                                                         Further, in no event shall liability of Omron Companies exceed the individual

8.   Financial. If the financial position of Buyer at any time becomes unsatisfactory                        price of the Product on which liability is asserted.

     to Omron, Omron reserves the right to stop shipments or require satisfactory                       15.  Indemnities. Buyer shall indemnify and hold harmless Omron Companies and

     security or payment in advance. If Buyer fails to make payment or otherwise                             their   employees       from   and  against  all  liabilities,  losses,     claims,     costs     and

     comply with these Terms or any related agreement, Omron may (without liabil-                            expenses (including attorney's fees and expenses) related to any claim, inves-

     ity and in addition to other remedies) cancel any unshipped portion of Prod-                            tigation, litigation or proceeding (whether or not Omron is a party) which arises

     ucts  sold  hereunder   and     stop  any    Products     in  transit  until  Buyer    pays  all        or is alleged to arise from Buyer's acts or omissions under these Terms or in

     amounts,    including   amounts     payable      hereunder,   whether   or    not  then      due,       any way with respect to the Products.        Without limiting the foregoing, Buyer (at

     which are owing to it by Buyer. Buyer shall in any event remain liable for all                          its own expense) shall indemnify and hold harmless Omron and defend or set-

     unpaid accounts.                                                                                        tle any action brought against such Companies to the extent based on a claim

9.   Cancellation;     Etc.  Orders   are  not    subject  to  rescheduling        or  cancellation          that any Product made to Buyer specifications infringed intellectual property

     unless Buyer indemnifies Omron against all related costs or expenses.                                   rights of another party.

10.  Force Majeure. Omron shall not be liable for any delay or failure in delivery                      16.  Property; Confidentiality. Any intellectual property in the Products is the exclu-

     resulting from causes beyond its control, including earthquakes, fires, floods,                         sive property of Omron Companies and Buyer shall not attempt to duplicate it

     strikes or other labor disputes, shortage of labor or materials, accidents to                           in  any  way     without  the   written  permission    of   Omron.       Notwithstanding          any

     machinery, acts of sabotage, riots, delay in or lack of transportation or the                           charges to Buyer for engineering or tooling, all engineering and tooling shall

     requirements of any government authority.                                                               remain the exclusive property of Omron. All information and materials supplied

11.  Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:                              by Omron to Buyer relating to the Products are confidential and proprietary,

     a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship                          and Buyer shall limit distribution thereof to its trusted employees and strictly

          except in “break down” situations.                                                                 prevent disclosure to any third party.

     b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall                 17.  Export Controls. Buyer shall comply with all applicable laws, regulations and

          constitute delivery to Buyer;                                                                      licenses regarding (i) export of products or information; (iii) sale of products to

     c. All sales and shipments of Products shall be FOB shipping point (unless                              “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of

          otherwise stated in writing by Omron), at which point title and risk of loss                       regulated technology or information.

          shall pass from Omron to Buyer; provided that Omron shall retain a security                   18.  Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right

          interest in the Products until the full purchase price is paid;                                    and no course of dealing between Buyer and Omron shall operate as a waiver

     d. Delivery and shipping dates are estimates only; and                                                  of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder

     e. Omron    will  package  Products      as  it  deems    proper   for  protection     against          without Omron's written consent. (c) Law. These Terms are governed by the

          normal handling and extra charges apply to special conditions.                                     law of the jurisdiction of the home office of the Omron company from which

12.  Claims. Any claim by Buyer against Omron for shortage or damage to the                                  Buyer    is  purchasing   the     Products   (without  regard       to   conflict  of   law  princi-

     Products occurring before delivery to the carrier must be presented in writing                          ples).   (d) Amendment. These Terms constitute the entire agreement between

     to Omron within 30 days of receipt of shipment and include the original trans-                          Buyer and Omron relating to the Products, and no provision may be changed

     portation bill signed by the carrier noting that the carrier received the Products                      or waived unless in writing signed by the parties. (e) Severability. If any provi-

     from Omron in the condition claimed.                                                                    sion hereof is rendered ineffective or invalid, such provision shall not invalidate

13.  Warranties.    (a)  Exclusive   Warranty.    Omron’s    exclusive      warranty    is  that  the        any other provision. (f) Setoff. Buyer shall have no right to set off any amounts

     Products will be free from defects in materials and workmanship for a period of                         against the amount owing in respect of this invoice. (g) Definitions. As used

     twelve months from the date of sale by Omron (or such other period expressed                            herein, “including” means “including without limitation”; and “Omron Compa-

     in writing by Omron). Omron disclaims all other warranties, express or implied.                         nies” (or similar words) mean Omron Corporation and any direct or indirect

     (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,                                             subsidiary or affiliate thereof.

     EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1.   Suitability of Use. Omron Companies shall not be responsible for conformity                             ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-

     with any standards, codes or regulations which apply to the combination of the                          ERLY     RATED   AND      INSTALLED      FOR      THE  INTENDED             USE    WITHIN         THE

     Product in the Buyer’s application or use of the Product. At Buyer’s request,                           OVERALL EQUIPMENT OR SYSTEM.

     Omron will provide applicable third party certification documents identifying                      2.   Programmable Products. Omron Companies shall not be responsible for the

     ratings and limitations of use which apply to the Product. This information by                          user’s programming of a programmable Product, or any consequence thereof.

     itself is not sufficient for a complete determination of the suitability of the Prod-              3.   Performance      Data.    Data    presented  in   Omron     Company         websites,        catalogs

     uct in combination with the end product, machine, system, or other application                          and other materials is provided as a guide for the user in determining suitabil-

     or use. Buyer shall be solely responsible for determining appropriateness of                            ity and does not constitute a warranty. It may represent the result of Omron’s

     the particular Product with respect to Buyer’s application, product or system.                          test conditions, and the user must correlate it to actual application require-

     Buyer shall take application responsibility in all cases but the following is a                         ments. Actual performance is subject to the Omron’s Warranty and Limitations

     non-exhaustive list of applications for which particular attention must be given:                       of Liability.

     (i)   Outdoor use, uses involving potential chemical contamination or electrical                   4.   Change       in  Specifications.    Product  specifications     and      accessories         may  be

     interference, or conditions or uses not described in this document.                                     changed at any time based on improvements and other reasons. It is our prac-

     (ii)  Use in consumer products or any use in significant quantities.                                    tice to change part numbers when published ratings or features are changed,

     (iii) Energy control systems, combustion systems, railroad systems, aviation                            or when significant construction changes are made. However, some specifica-

     systems, medical equipment, amusement machines, vehicles, safety equip-                                 tions of the Product may be changed without any notice. When in doubt, spe-

     ment, and installations subject to separate industry or government regulations.                         cial part numbers may be assigned to fix or establish key specifications for

     (iv) Systems, machines and equipment that could present a risk to life or prop-                         your application. Please consult with your Omron’s representative at any time

     erty. Please know and observe all prohibitions of use applicable to this Product.                       to confirm actual specifications of purchased Product.

     NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS                                         5.   Errors and Omissions. Information presented by Omron Companies has been

     RISK  TO     LIFE   OR  PROPERTY         OR      IN  LARGE    QUANTITIES           WITHOUT              checked and is believed to be accurate; however, no responsibility is assumed

     ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO                                                for clerical, typographical or proofreading errors or omissions.

                                                                                                                          Temperature Controllers E5CSV                                                        19
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website

at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

OMRON ELECTRONICS LLC                MEXICO SALES OFFICES                       OMRON ON-LINE

1 Commerce Drive                     Mexico, D.F.     (52) 555 660 31 44        Global –

Schaumburg, IL 60173                 Ciudad Juárez    (52) 656 623 70 83        www.omron.com

Tel: 847.843.7900                    Monterrey, N.L.  (52) 818 377 42 81        USA –

                                     Mexicali, B.C.   (52) 686 838 01 15        www.omron247.com

For U.S. technical support or other                                             Canada –

inquiries: 800.556.6766              BRAZIL SALES OFFICES                       www.omron.ca

                                     Sao Paulo        (55) 11 2101 6300

OMRON CANADA, INC.                                                              Brazil –

885 Milner Avenue                    ARGENTINA SALES OFFICES                    www.omron.com.br

Toronto, Ontario M1B 5V8             Cono Sur         (54) 11 4787 1129

Tel: 416.286.6465

                                     CHILE SALES OFFICES

                                     Santiago         (56) 2206 4592

                                     OTHER LATIN AMERICAN SALES

                                     mela@omron.com

Cat. No. H138-E3-02       07/07      Specifications subject to change without notice                         Printed  in  USA
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Omron: