电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

E5CS-RPU-W-AC100-240

器件型号:E5CS-RPU-W-AC100-240
器件类别:热门应用    机电_工控_自动化   
厂商名称:OMRON
厂商官网:https://www.omron.com
下载文档

器件描述

Controllers Temperature Control

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Controllers
RoHS:YES
系列:
Series:
E5CS
商标:
Brand:
Omron Automation and Safety
工厂包装数量:
Factory Pack Quantity:
1
零件号别名:
Part # Aliases:
E5CSRPUWAC100240
单位重量:
Unit Weight:
3.880136 oz

E5CS-RPU-W-AC100-240器件文档内容

     E5CS Temperature Controllers

                                                                                                                        CSM_E5CS_DS_E_5_3

Simple Functions in DIN 48 × 48 mm-size
Plug-in Temperature Controllers

• Easy setting using DIP switch.

• Models with two alarms added to Series, ideal for applications

requiring alarms.

• Universal-input (thermocouple/platinum resistance

thermometer) models also available.

• Clearly visible digital display with character height of 13.5 mm.

• RoHS compliant.

         Refer to Safety Precautions for All Temperature

         Controllers.                                                        For the most recent information on models that have been certified for

                                                                             safety standards, refer to your OMRON website.

                                                                             Refer to E5CS/E5CSV Operation for

                                                                             operating procedures.

Model Number Structure

■ Model Number Legend

Plug-in Models

E5CS-@@@@U-W

         1     2   3   4  5  6

31.  Control Outputs                          3.          Input                                     4.  Power Supply Voltage

     R: Relay                                             KJ:  Thermocouple                             Blank: 100 to 240 VAC

     Q: Voltage for driving SSR                           P:   Platinum resistance thermometer          D:  24 VAC/VDC

2.   Alarm Outputs                                        G:   Thermistor                           5.  Terminal Shape

     Blank: No alarm                                      T:   Thermocouple/platinum resistance         U:  Plug-in

     1:  1 alarm                                               thermometer (universal-input)        6.  Case Color

     2:  2 alarms                                                                                       W:  Light gray

Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to

         Ordering Information when ordering.

         Examples

         • Relay control output, without alarm, thermocouple input, plug-in construction, light gray case: E5CS-RKJU-W

         • Relay control output, one alarm output, platinum resistance thermometer input, plug-in construction, light gray case: E5CS-R1PU-W

                                                                                                                                                     1
                                                                                                                              E5CS

Ordering Information

■ List of Models

Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer,

Power Supply Voltage: 100 to 240 VAC

Size        Type           Control                   Alarms            Outputs                  Model with        Model with platinum

                           modes                                                                thermocouple             resistance

                                                                                                                         thermometer

E5CS-U      Plug-in        ON/OFF or              0             Relay                      E5CS-RKJU-W            E5CS-RPU-W

48 × 48 mm                 PID                                  Voltage (for driving SSR)  E5CS-QKJU-W            E5CS-QPU-W

                                                  1             Relay                      E5CS-R1KJU-W           E5CS-R1PU-W

                                                                Voltage (for driving SSR)  E5CS-Q1KJU-W           E5CS-Q1PU-W

Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer,

Power Supply Voltage: 24 VAC/VDC

Size        Type           Control                   Alarms            Outputs                  Model with        Model with platinum

                           modes                                                                thermocouple             resistance

                                                                                                                         thermometer

E5CS-U      Plug-in        ON/OFF or              0             Relay                      E5CS-RKJDU-W           E5CS-RPDU-W

48 × 48 mm                 PID                                  Voltage (for driving SSR)  E5CS-QKJDU-W           ---

                                                  1             Relay                      E5CS-R1KJDU-W          E5CS-R1PDU-W

                                                                Voltage (for driving SSR)  E5CS-Q1KJDU-W          ---

Case Color: Light Gray, Thermistor or Universal-input, Power Supply Voltage: 100

to 240 VAC

Size        Type           Control                   Alarms            Outputs             Model with thermistor  Model with universal-

                           modes                                                                                  input (thermocouple

                                                                                                                         and platinum

                                                                                                                         resistance

                                                                                                                         thermometer)

E5CS-U      Plug-in        ON/OFF or              0             Relay                      E5CS-RGU-W             E5CS-RTU-W

48 × 48 mm                 PID                                  Voltage (for driving SSR)  E5CS-QGU-W             E5CS-QTU-W

                                                  1             Relay                      E5CS-R1GU-W            E5CS-R1TU-W

                                                                Voltage (for driving SSR)  E5CS-Q1GU-W            E5CS-Q1TU-W

                                                  2             Relay                      ---                    E5CS-R2TU-W

                                                  (See note.)   Voltage (for driving SSR)                         E5CS-Q2TU-W

Note: There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting,

change the alarm type for alarm output 2 in initial setting level 5. For details, refer to the “E5CSV/E5CS-U Digital Temperature Controller

User’s Manual” (Cat. No. H140-E1-01).

Case Color: Light Gray, Thermistor, Power Supply Voltage: 24 VAC/VDC

Size        Type           Control                   Alarms            Outputs             Model with thermistor

                           modes

E5CS-U      Plug-in        ON/OFF or              0             Relay                      E5CS-RGDU-W

48 × 48 mm                 PID                    1                                        E5CS-R1GDU-W

■ Accessories (Order Separately)

Socket without Alarm (8 Pins)                                          Socket with Alarm (11 Pins)

                     Type                            Model                                      Type                     Model

Front Connecting Socket                              P2CF-08           Front Connecting Socket                           P2CF-11

Back Connecting Socket (flush mounting)              P3G-08            Back Connecting Socket (flush mounting)           P3GA-11

Front Connecting Socket (with finger protection)     P2CF-08-E         Front Connecting Socket (with finger protection)  P2CF-11-E

Finger Safe Terminal Cover for P3G                   Y92A-48G          Finger Safe Terminal Cover for P3G                Y92A-48G

                                                                       Protective Cover

                                                                                                Type                     Model

                                                                       Hard Protective Cover                             Y92A-48B

                                                                                                                                                2
                                                                                                                                             E5CS

Specifications

■ Ratings

Supply voltage                  100 to 240 VAC, 50/60 Hz

                                24 VAC, 50/60 Hz; 24 VDC

Operating voltage range         85% to 110% of rated supply voltage

Power consumption               100 to 240 VAC: 5 VA

                                24 VAC: 3 VA, 24 VDC: 2 W

Sensor input                    Thermocouple:                                                K, J, L

                                Platinum resistance thermometer:                             Pt100, JPt100

                                Thermistor:                                                  E52-THE@@

                                Universal-input (thermocouple/platinum resistance thermometer): K, J, L, T, U,   N,      R,  Pt100,  JPt100

Control  Relay output           SPDT, 250 VAC, 3 A (resistive load)

output   Voltage output         12 VDC, 21 mA (with short-circuit protection circuit)

         (for driving the SSR)

Control method                  ON/OFF or 2-PID (with automatic PID parameter setting function)

Alarm output                    SPST-NO, 250 VAC, 1A (resistive load)

Setting method                  Digital setting using front panel keys

Indication method               7-segment digital display (character height: 13.5 mm) and deviation indicators

Other functions                 • Setting change prohibit (key protection)

                                • Input shift

                                • Temperature unit change (°C/°F)

                                • Direct/reverse operation

                                • Temperature range, Sensor switching (K/J/L, Pt100/JPt100)

                                • Switching is performed between a thermocouple and platinum resistance thermometer          for     universal-input

                                models.

                                • Control period switching

                                • 8-mode alarm output

                                • Sensor error detection (excluding thermistor models)

Ambient operating               −10 to 55°C (with no condensation or icing); with 3-year guarantee: −10 to 50°C

temperature

Ambient operating humidity      25% to 85%

Storage temperature             −25 to 65°C (with no condensation or icing)

Note: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.)

                                                                                                                                                      3
                                                                                                                                                            E5CS

■ Characteristics

Setting accuracy                    Thermocouple (See note 1.):                      (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

Indication accuracy                 Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max.

(ambient temperature of 23°C)       Thermistor (See note 3.):                        (1% FS of indication value) ±1 digit max.

Influence of temperature            R thermocouple inputs:                       (±2% of PV or ±10°C, whichever is greater) ±1 digit max.

Influence of voltage                Other thermocouple inputs:                   (±2% of PV or ±4°C, whichever is greater) ±1 digit max.

Influence of EMS.                   Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

(at EN 61326-1)                     Thermistor:                                  (±2% FS) ±1 digit max.

Hysteresis (for ON/OFF control)     0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models)

Proportional band (P)               1 to 999°C (automatic adjustment using auto-tuning/self-tuning)

Integral time (I)                   1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Derivative time (D)                 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Alarm output range                  Absolute-value alarm: Same as the control range

                                    Other:                  0 to input setting range full scale (°C or °F)

                                    Alarm hysteresis:       0.2°C or °F (fixed)

Control period                      2/20 s

Sampling period                     500 ms

Insulation resistance               20 MΩ min. (at 500 VDC)

Dielectric strength                 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity

Vibration              Malfunction  10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance
                       Destruction  10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions

Shock resistance       Malfunction  100 m/s2 min., 3 times each in six directions

                       Destruction  300 m/s2 min., 3 times each in six directions

Life expectancy        Electrical   100,000 operations min. (relay output models)

Weight                              Approx. 110 g (Controller only)

Degree of protection                Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00

Memory protection                   EEPROM (non-volatile memory) (number of writes: 1,000,000)

EMC                                 EMI Radiated:                                  EN 55011 Group 1 Class A

                                    EMI Conducted:                                 EN 55011 Group 1 Class A

                                    Radiated Electromagnetic Field Immunity:       EN 61000-4-2: 4 kV contact discharge (level 2)
                                                                                                     8 kV air discharge (level 3)

                                    RF-interference Immunity:                      EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3)
                                                                                                     10 V/m (900 MHz pulse modulated)

                                    Conducted Disturbance Immunity:                EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2)

                                    Noise Immunity (First Transient Burst Noise): EN 61000-4-4

                                    Burst Immunity:                                2 kV power-line (level 3), 1 kV I/O signal-line (level 3)

                                    Surge Immunity:                                EN 61000-4-5: Power line:                       Normal mode 1 kV; Common mode 2 kV
                                                                                                     Output line (relay output): Normal mode 1 kV; Common mode 2 kV

                                    Voltage Dip/Interrupting Immunity:             EN 61000-4-11 0.5 cycle, 100% (rated voltage)

Approved standards                  UL 61010-1 (listing)

                                    CSA C22.2 No.1010-1

Conformed standards                 EN 61326-1 (See note 4.), EN 61010-1, IEC 61010-1

Note: 1.   The following exceptions apply to thermocouples.
           • U, L: ±2°C ±1 digit max.
           • R:    ±3°C ±1 digit max. at 200°C or less

     2.    The following exception applies to platinum resistance thermometers.
           • Input set values 1 for E5CS-U: 1% FS ±1 digit max.

     3.    The following exceptions apply to thermistors.
           • When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate.
           • When the unit setting is °F, the temperature range for the input setting numbers 4 and 9 (609 to 630°F) and temperature indication
            ranges exceeding the set temperature range −5% FS to +10% FS may not be accurate.

     4.    Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

                                                                                                                                                                       4
                                                                                                                                                         E5CS

■ Temperature Range

Thermocouple Input                       Models

                              Input                              K                                                J/L

               Temperature    1,000                                                        999

   9  0  1     range          900

8           2                 800

7           3  (selected      700                                               600

         4     using switch)  600                                   500                                                       500

   6  5                       500                         400                                                          400

                              400                  300                                                     300

(Default    setting: 2)       300        200                                                        200

                              200

                              100

                                     0   0         0      0         0           0          0        0      0           0      0

                         Setting number  0         1      2         3           4          5        6      7           8      9         The shaded value indicates the default

               Minimum setting unit                            1°C                                              1°C                     setting status.

Platinum Resistance Thermometer                                              Input Models

      0        Temperature    Input                                          JPt100/Pt100

   9     1     range

8           2                 500                                                                   400                400

               (selected      400                                                          300             300

7           3                 300

   6  5  4     using switch)  200                                               200                                           199.9

                              100        50        50.0   80        99.9

(Default    setting: 3)              0             0.0              0.0         0          0        0      0           0      0.0

                              −100       −50              −20

                         Setting number  0         1      2         3           4          5        6      7           8      9         The shaded value indicates the default

               Minimum setting unit      1°C       0.1°C  1°C       0.1°C                           1°C                       0.1°C     setting status.

Thermistor Input Models (For details on Sensors, refer                                                                        to E52.)

                              Input                                                   G

      0        Temperature               6 kΩ      6 kΩ   30 kΩ     550 Ω       4 kΩ       6 kΩ     6 kΩ   30 kΩ   550 Ω      4 kΩ

   9     1     range                     (0°C)     (0°C)  (0°C)     (200°C)  (200°C)     (0°C)      (0°C)  (0°C)   (200°C)    (200°C)

8           2  (selected

7           3                 500

         4     using switch)  400                                               300                                           300

   6  5                       300                         150       200                                    150         200

                              200        50        100                                     50       100

                              100                                   100         150                                    100    150

(Default    setting: 1)              0             0      50                                        0      50

                              −100       −50                                               −50

                         Setting number  0         1      2         3           4          5        6      7           8      9         The shaded value indicates the default

               Minimum setting unit                                                   1°C                                               setting status.

Universal-input (Thermocouple/Platinum Resistance Thermometer) Models

• Using     Thermocouple Sensors,               Control   Mode Switch 5: OFF

                              Input             K                J              L                T         U           N      R

                              1,700                                                                                           1,700

                              1,600

                              1,500

                              1,400      1,300                                                                         1,300

      0        Temperature    1,300

   9     1     range          1,200

8           2  (selected      1,100

7           3  using switch)  1,000                       850                   850

         4                    900

   6  5                       800

                              700

(Default    setting: 0)       600

                              500                                                          400             400

                              400

                              300                  199.9            199.9                           199.9

                              200

                              100

                                     0             0.0              0.0                             0.0                       0

                              −100       −99              −99                   −99        −99             −99         −99

                         Setting number  0         1      2         3           4          5        6      7           8      9         The shaded value indicates the default

               Minimum setting unit      1°C       0.1°C  1°C       0.1°C             1°C           0.1°C              1°C              setting status.

• Using     Platinum Resistance          Thermometers,           Control Mode Switch 5: ON

                              Input                       Pt100                                            JPt100

      0        Temperature    1,000      850

   9     1     range          900

8           2  (selected      800

7           3  using switch)  700

         4                    600                                                          500

   6  5                       500                                               400                                           400

                              400

(Default    setting: 0)       300                  199.9            200                             199.9              200

                              200                         99                                               99

                              100

                                     0             0.0              0           0                   0.0                0      0

                              −100       −99              −99                              −99             −99

                         Setting number  0         1      2         3           4          5        6      7           8      9         The shaded value indicates the default

               Minimum setting unit      1°C       0.1°C                   1°C                      0.1°C              1°C              setting status.

                                                                                                                                                                                5
                                                                                                                                                                                E5CS

External           Connection Diagram

          Sensor           Thermocouple (See note 3.)                           Platinum resistance thermometer                                          Thermistor

                                                                                               (See note 3.)

Plug-in   Without  Voltage output models (See note 1.)                          Voltage output models (See note 1.)                       Voltage output models (See note 1.)

models    alarms                          12 VDC,                                              12 VDC,                                                   12 VDC,

                                          21 mA                                                   21 mA                                                     21 mA

                                                            Voltage                                               Voltage                                                 Voltage

                                          4     5           output                             4        5         output                                 4     5          output

                   Relay output models                                          Relay output models                                       Relay output models

                                                                                   A

                                             4     5                                                 4     5                                                4      5

                                   3                      6                                    3                  6                            3                          6

                           (K, J)

                                   2                      7                     B  B           2                  7                            2                          7

                                             1     8                                                 1     8                                                1      8

                                                          100 to 240 VAC                                           100 to 240 VAC                                         100 to 240 VAC

                                                          24 VAC/VDC                                               24 VAC/VDC                                             24 VAC/VDC

                                                          (See note 2.)                                            (See note 2.)                                          (See note 2.)

          With     Voltage output models                     Two alarm          Voltage output models              Two alarm              Voltage output models

          alarms   (See note 1.)                             points             (See note 1.)                      points                 (See note 1.)

                           12 VDC, 21 mA         7                              12 VDC, 21 mA              7                              12 VDC, 21 mA

                           OUT                                                        OUT                                                 OUT

                                                      8         Alarm output 1                                 8          Alarm output 1

                                          5           9                                           5            9          Alarm output 2                 5

                                   4                            Alarm output 2             4                                                   4

                   Relay output models                                          Relay output models                                       Relay output models

                                                          Alarm output                                         Alarm output                                               Alarm output

                                             5     6     7                                        5     6     7                                             5      6  7

                                          4                  8                                 4                  8                                      4                8

                                          3                  9                     A           3                  9                                      3                   9

                                             2  1     11  10                                      2  1     11  10                                           2  1      11  10

                                                             100 to 240 VAC                B                      100 to 240 VAC                                             100 to 240 VAC

                                                             24 VAC/VDC         B                                 24 VAC/VDC                                                 24 VAC/VDC

                                                             (See note 2.)                                        (See note 2.)                                              (See note 2.)

Note: 1.  The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not

          connect output terminals 4 or 5 to ground. Otherwise, unwanted current paths will cause measurement errors.

2.        Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity.

3.        Be sure to check the sensor type before using multi-output (thermocouple/platinum resistance thermometer) models.

Nomenclature

E5CS-U Plug-in Models

                                                Temperature display

                                                                                   Output indicator

Deviation indicators

          Mode indicators                                                          Alarm indicators

          Mode Key                                                                 Up Key

                                                      Down key

                                                                                                                                                                                             6
                                                                                                                                                                            E5CS

Dimensions

Note: All units are in millimeters unless otherwise indicated.

■ Controller

E5CS-U                                                                                                                             Terminal Arrangement

                                                                                                                                          (Bottom View)

                                                                        94.45                                                   4   5                          5     6  7

                                    (7.75)                                                                                   3            6              4                  8

                       48 × 48      6.25                                72.5                                                                             3                  9

                                                                                                                             2            7                 2               10

                                                                                                                                1   8                             1     11

                                                                                                44.8  ×  44.8            Models without                  Models with

                                                                                                                                alarms                      alarms

                                                                                                                                Panel Cutout     Dimensions

                                                                                                                                45  +0.6

                                                                                                                                    0                                   L

                       Note: The external dimensions are           the  same for   both  models

                              with and without alarms.                                                              45+00.6                  45+00.6

                                                                                                               60  min.                          L = (48 × N − 2.5)+01

                                                                                                                                                 Mounting side-by-side

                                                                                                                                                 (group mounting of N Controllers)

E5CS-U + Adapter  for  Flush  Mounting (Enclosed)               +  Back Connecting Socket (Order Separately)

(Without Alarms)

                                                                   Adapter for           Panel  Y92F-30 Adapter for flush mounting

                                                                   flush mounting                                               P3G-08

                                                                                                                                Back Connecting  Socket

                                58

                                            48                                                           Tightening screws

                                                                                   7                           95

E5CS-U + Adapter  for  Flush  Mounting (Enclosed)               +  Back Connecting Socket (Order Separately)

(With Alarms)

                                                                   Adapter for           Panel  Y92F-30 Adapter for flush mounting

                                                                   flush mounting                                               P3GA-11

                                                                                                                                Back Connecting  Socket

                                58

                                            48                                                           Tightening screws

                                                                                   7                           100

Note: Use the P2CF-08 and P3G-08 Sockets for models without alarms, and use the P2CF-11 and P3GA-11 Sockets for models                                               with   alarms.

                                                                                                                                                                                     7
                                                                                                                                                                              E5CS

■ Accessories (Order Separately)

8-pin Sockets without Alarms                                                                                     Terminal Arrangement/

                                                                                                                 Internal Connections

P2CF-08 Front Connecting Socket         Eight, M3.5 × 7.5                                                                 (Top View)

                                        sems screws            7.8                   3                  4.5                                     Mounting Hole Dimensions

                                                                                                                             6  5   4     3

                                                                                                                                                             Two, 4.5-dia. hole or two, M4

                                                               Two,

                                                               4.5-dia.

                                                               holes                                                                                             40±0.2

                                 70 max.                                                                35.4

                                                                                                                                                Note:     DIN Track mounting is also

                                                                                                                             7  8   1     2               possible.

                                    4     50 max.                                                       Note:       The P2CF-08-E Socket with finger protection is also available.

                                                                                            20.3  max.

P3G-08 Back Connecting Socket                                                                                                                   Terminal Arrangement

                                                 27 dia.                                                               7                        (Bottom View)

                                                                                                                                9               3         4  5   6

                                    45

                                                                                                                                                2         1  8   7

                                                 45                                     17                             M3.5

                                                                                  4.9                                           8

                                                                                                        Note:       The Y92A-48G Finger Safe Terminal Cover is also available.

11-pin Sockets with Alarms                                                                                       Terminal Arrangement/

P2CF-11 Front Connecting Socket                                                                                  Internal Connections

                                    Eleven, M3.5 × 7.5         7.8                3                     4.5               (Top View)

                                    sems screws

                                                                                                                             8  7   6  5        Mounting Hole Dimensions

                                                               Two,                                                                       4

                                                               4.5-dia.                                                                                      Two, 4.5-dia. mounting holes

                                                               holes

                                 70 max.                                                                35.4

                                                                                                                                                                 40±0.2

                                                                                                                          9               3

                                                                                                                             10 11  1  2        Note:  DIN Track mounting is also

                                                                                                                                                       possible.

                                 4        50 max.                                           31.2 max.   Note:       The P2CF-11-E Socket        with finger protection is also available.

                                                                                                                                                Terminal Arrangement

P3GA-11 Back Connecting Socket            27 dia.                                                             4     7     3                     (Bottom View)

                                                                                                                                                       5  6  7   8

                                                                                                                                                4

                                    45                                                            25.6

                                                                                                                                                3                9

                                                                                                                                                       2  1  11  10

                                                 45                               4.5 16.3 6.2                                               6

                                                                                                        8.7

                                                                                                             Note:     The Y92A-48G Finger Safe Terminal Cover is also available.

Note:  Do not use any other types of Sockets. Doing so will adversely affect the     accuracy.

Applicable Thermistors                                                                          Hard Protective Cover

Use Element Interchangeable Thermistors (E52-THE5A, E52-                                        The Y92A-48B Hard Protective Cover is available                      for the  following

THE6D, and E52-THE6F) to connect to the E5CS-@GU. For details                                   applications.

on Sensors, refer to E52.                                                                       • To protect the set from dust and dirt.

                                                                                                • To prevent the panel from being

                                                                                                  accidentally touched causing displacement

                                                                                                  of set values.

                                                                                                • To provide effective protection against                            92A-48B

                                                                                                  water droplets.

                                                                                                                                                                                            8
                                                                                                                      E5CS

Safety Precautions

Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                            9
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2015.8

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2015 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

E5CS-QGU-W AC100-240    E5CS-RKJU-W AC100-240   E5CS-Q1KJU-W AC100-240  E5CS-QKJU-W AC100-240

E5CS-QPU-W AC100-240    E5CS-R1KJU-W AC100-240  E5CS-RPU-W AC100-240  E5CS-R1P  E5CS-RKJDU-

WAC/DC24

小广播

E5CS-RPU-W-AC100-240器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved