器件描述

controllers No alm relay out the rmistor In

参数

Manufacturer: Omron
Product Category: Controllers
RoHS: Yes
Brand: Omron Automation and Safety

E5CS-RGU-W AC100-240器件文档内容

Temperature Controllers

E5CS

                                                                                                               CSM_E5CS_DS_E_5_1

Simple Functions in DIN 48 48 mm-size                              Refer to E5CS/E5CSV Operation for
Plug-in Temperature Controllers                                      operating procedures.

Easy setting using DIP switch.
Models with two alarms added to Series, ideal for applications

requiring alarms.
Universal-input (thermocouple/platinum resistance

thermometer) models also available.
Clearly visible digital display with character height of 13.5 mm.
RoHS compliant.

        Refer to Safety Precautions for All Temperature
        Controllers.

Model Number Structure

Model Number Legend

Plug-in Models

E5CS-@@@@U-W

              1 2345 6

3                               3. Input                                 4. Power Supply Voltage
                                    KJ: Thermocouple                         Blank: 100 to 240 VAC
1. Control Outputs                  P: Platinum resistance thermometer       D: 24 VAC/VDC
    R: Relay                        G: Thermistor
    Q: Voltage for driving SSR      T: Thermocouple/platinum resistance  5. Terminal Shape
                                          thermometer (universal-input)      U: Plug-in
2. Alarm Outputs
    Blank: No alarm                                                      6. Case Color
    1: 1 alarm                                                               W: Light gray
    2: 2 alarms

Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to
        Ordering Information when ordering.

Examples
Relay control output, without alarm, thermocouple input, plug-in construction, light gray case: E5CS-RKJU-W

Relay control output, one alarm output, platinum resistance thermometer input, plug-in construction, light gray case: E5CS-R1PU-W

                                                                                                                                                    1
                                                                                                                 E5CS

Ordering Information

List of Models

Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer,
Power Supply Voltage: 100 to 240 VAC

Size        Type     Control                      Alarms                    Outputs               Model with      Model with platinum
                     modes                                                                      thermocouple              resistance
                                                               Relay
E5CS-U      Plug-in  ON/OFF or 0                               Voltage (for driving SSR)  E5CS-RKJU-W                   thermometer
                     PID                                       Relay                      E5CS-QKJU-W
48 48 mm                                                     Voltage (for driving SSR)  E5CS-R1KJU-W           E5CS-RPU-W
                                         1                                                E5CS-Q1KJU-W
                                                                                                                 E5CS-QPU-W

                                                                                                                 E5CS-R1PU-W

                                                                                                                 E5CS-Q1PU-W

Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer,
Power Supply Voltage: 24 VAC/VDC

Size        Type     Control                      Alarms                    Outputs               Model with       Model with platinum
                     modes                                                                      thermocouple              resistance
                                                               Relay
E5CS-U      Plug-in  ON/OFF or 0                               Voltage (for driving SSR)  E5CS-RKJDU-W                  thermometer
                     PID                                       Relay                      E5CS-QKJDU-W
48 48 mm                                                     Voltage (for driving SSR)  E5CS-R1KJDU-W          E5CS-RPDU-W
                                         1                                                E5CS-Q1KJDU-W
                                                                                                                 ---

                                                                                                                 E5CS-R1PDU-W

                                                                                                                 ---

Case Color: Light Gray, Thermistor or Universal-input, Power Supply Voltage: 100
to 240 VAC

Size        Type     Control                      Alarms                    Outputs       Model with thermistor  Model with universal-
                     modes                                                                                       input (thermocouple
                                                               Relay
                                                               Voltage (for driving SSR)                               and platinum
                                                               Relay                                                    resistance
                                                               Voltage (for driving SSR)
                                                               Relay                                                  thermometer)
                                                               Voltage (for driving SSR)
E5CS-U      Plug-in  ON/OFF or 0                                                          E5CS-RGU-W             E5CS-RTU-W
                     PID
48 48 mm                                                                                E5CS-QGU-W             E5CS-QTU-W
                                         1
                                                                                          E5CS-R1GU-W            E5CS-R1TU-W
                                         2
                                         (See note.)                                      E5CS-Q1GU-W            E5CS-Q1TU-W

                                                                                          ---                    E5CS-R2TU-W

                                                                                                                 E5CS-Q2TU-W

Note: There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting,
        change the alarm type for alarm output 2 in initial setting level 5. For details, refer to the "E5CSV/E5CS-U Digital Temperature Controller
        User's Manual" (Cat. No. H140-E1-01).

Case Color: Light Gray, Thermistor, Power Supply Voltage: 24 VAC/VDC

Size        Type         Control       Alarms                               Outputs       Model with thermistor
                         modes                                 Relay
E5CS-U      Plug-in               0                                                       E5CS-RGDU-W
                     ON/OFF or    1                                                       E5CS-R1GDU-W
48 48 mm           PID

Accessories (Order Separately)

Socket without Alarm (8 Pins)                                  Socket with Alarm (11 Pins)

                             Type                       Model                               Type                       Model
Front Connecting Socket                           P2CF-08      Front Connecting Socket                           P2CF-11
Back Connecting Socket (flush mounting)           P3G-08       Back Connecting Socket (flush mounting)           P3GA-11
Front Connecting Socket (with finger protection)  P2CF-08-E    Front Connecting Socket (with finger protection)  P2CF-11-E
Finger Safe Terminal Cover for P3G                Y92A-48G     Finger Safe Terminal Cover for P3G                Y92A-48G

                                                               Protective Cover                                         Model
                                                                                                                 Y92A-48B
                                                                                             Type
                                                               Hard Protective Cover

                                                                                                                                                     2
                                                                                                                             E5CS

Specifications

Ratings

Supply voltage           100 to 240 VAC, 50/60 Hz
                         24 VAC, 50/60 Hz; 24 VDC

Operating voltage range  85% to 110% of rated supply voltage

Power consumption        100 to 240 VAC: 5 VA
                         24 VAC: 3 VA, 24 VDC: 2 W

Sensor input             Thermocouple:                                           K, J, L

                         Platinum resistance thermometer:                        Pt100, JPt100

                         Thermistor:                                             E52-THE@@

                         Universal-input (thermocouple/platinum resistance thermometer): K, J, L, T, U, N, R, Pt100, JPt100

Control Relay output     SPDT, 250 VAC, 3 A (resistive load)

output Voltage output    12 VDC, 21 mA (with short-circuit protection circuit)

(for driving the SSR)

Control method           ON/OFF or 2-PID (with automatic PID parameter setting function)

Alarm output             SPST-NO, 250 VAC, 1A (resistive load)

Setting method           Digital setting using front panel keys

Indication method        7-segment digital display (character height: 13.5 mm) and deviation indicators

Other functions          Setting change prohibit (key protection)

                         Input shift
                         Temperature unit change (C/F)
                         Direct/reverse operation

                         Temperature range, Sensor switching (K/J/L, Pt100/JPt100)
                         Switching is performed between a thermocouple and platinum resistance thermometer for universal-input

                           models.
                         Control period switching

                         8-mode alarm output

                         Sensor error detection (excluding thermistor models)

Ambient operating        -10 to 55C (with no condensation or icing); with 3-year guarantee: -10 to 50C
temperature

Ambient operating humidity 25% to 85%

Storage temperature      -25 to 65C (with no condensation or icing)

Note: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.)

                                                                                                                                   3
                                                                                                                                             E5CS

Characteristics

Setting accuracy               Thermocouple (See note 1.):                        (1% of indication value or 2C, whichever is greater) 1 digit max.

Indication accuracy            Platinum resistance thermometer (See note 2.): (0.5% of indication value or 1C, whichever is greater) 1 digit max.
(ambient temperature of 23C)
                               Thermistor (See note 3.):                          (1% FS of indication value) 1 digit max.

Influence of temperature       R thermocouple inputs:                 (2% of PV or 10C, whichever is greater) 1 digit max.
Influence of voltage
                               Other thermocouple inputs:             (2% of PV or 4C, whichever is greater) 1 digit max.

                               Platinum resistance thermometer inputs: (1% of PV or 2C, whichever is greater) 1 digit max.

                               Thermistor:                            (2% FS) 1 digit max.

Hysteresis (for ON/OFF control) 0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models)

Proportional band (P)          1 to 999C (automatic adjustment using auto-tuning/self-tuning)

Integral time (I)              1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Derivative time (D)            1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Alarm output range             Absolute-value alarm: Same as the control range

                               Other:                0 to input setting range full scale (C or F)

                               Alarm hysteresis: 0.2C or F (fixed)

Control period                 2/20 s

Sampling period                500 ms

Insulation resistance          20 M min. (at 500 VDC)

Dielectric strength            2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity

Vibration              Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance             Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions

Shock resistance Malfunction 100 m/s2 min., 3 times each in six directions

                       Destruction 300 m/s2 min., 3 times each in six directions

Life expectancy Electrical 100,000 operations min. (relay output models)

Weight                         Approx. 110 g (Controller only)

Degree of protection           Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00

Memory protection              EEPROM (non-volatile memory) (number of writes: 1,000,000)

EMC                            EMI Radiated:                                      EN 55011 Group 1 Class A

                               EMI Conducted:                                     EN 55011 Group 1 Class A

                               Radiated Electromagnetic Field Immunity: EN 61000-4-2: 4 kV contact discharge (level 2)

                                                                                           8 kV air discharge (level 3)

                               RF-interference Immunity:                          EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3)

                                                                                           10 V/m (900 MHz pulse modulated)

                               Conducted Disturbance Immunity:                    EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2)

                               Noise Immunity (First Transient Burst Noise): EN 61000-4-4

                               Burst Immunity:                                    2 kV power-line (level 3), 1 kV I/O signal-line (level 3)

                               Surge Immunity:                                    EN 61000-4-5: Power line:            Normal mode 1 kV; Common mode 2 kV

                                                                                           Output line (relay output): Normal mode 1 kV; Common mode 2 kV

                               Voltage Dip/Interrupting Immunity:                 EN 61000-4-11 0.5 cycle, 100% (rated voltage)

Approved standards             UL 61010-1 (listing)
                               CSA C22.2 No.1010-1

Conformed standards            EN 61326, EN 61010-1, IEC 61010-1

Note: 1. The following exceptions apply to thermocouples.
             U, L: 2C 1 digit max.
             R: 3C 1 digit max. at 200C or less

        2. The following exception applies to platinum resistance thermometers.
             Input set values 1 for E5CS-U: 1% FS 1 digit max.

        3. The following exceptions apply to thermistors.
             When the unit setting is C, temperature indication ranges exceeding the set temperature range 10% FS may not be accurate.
             When the unit setting is F, the temperature range for the input setting numbers 4 and 9 (609 to 630F) and temperature indication
               ranges exceeding the set temperature range -5% FS to +10% FS may not be accurate.

                                                                                                                                                                 4
Temperature Range                                                                                                                                                                E5CS

Thermocouple Input Models                                                                                                                                          The shaded value indicates the default
                                                                                                                                                                   setting status.
                                  Input                                K                                                J/L
                                                                                                                                                                   The shaded value indicates the default
             Temperature          1,000                                                             999                                                            setting status.

    901      range                900
                                  800
78       23
                   (selected      700                                             600
                   using switch)
    456                           600                                       500                                                                        500
(Default setting: 2)456                                                                                                                  400
    456                           500                     400                                                             300
    456                                                                                                     200
    456                           400              300

                                  300    200
                                  200

                                  100

                                  0      0         0      0                 0     0                 0       0      0         0      0

                      Setting number 0             1      2                 3     4                 5       6      7         8      9

             Minimum setting unit                                      1C                                              1C

Platinum Resistance Thermometer Input Models

    901      Temperature Input                                                    JPt100/Pt100

78       23  range                500                                                                       400              400
             (selected                                                                                                                    199.9
             using switch)        400                                                               300            300

                                  300                                             200

                                  200    50        50.0   80                99.9

                                  100

(Default setting: 3)                   0           0.0                      0.0   0                 0       0      0         0      0.0
                                  -100 -50
                                                          -20

                      Setting number 0             1      2                 3     4                 5       6      7         89

             Minimum setting unit 1C 0.1C 1C 0.1C                                                       1C                     0.1C

Thermistor Input Models (For details on Sensors, refer to E52.)

                                  Input                                               G

    901      Temperature                 6 k       6 k    30 k 550  4 k 6 k                                 6 k    30 k 550  4 k
             range                       (0C)     (0C)  (0C) (200C) (200C) (0C)                       (0C)  (0C) (200C) (200C)

78       23  (selected            500      50       100                                                      100
                                          -50         0                                                        0
             using switch)        400                                             300                                               300
                                  300     0         1                                                        6
                                                          150               200                                    150       200
                                  200
                                                                                                    50
                                  100
                                                                            100   150                                        100    150
                                  0
(Default setting: 1)                                      50                                                       50
                                  -100
                                                                                                    -50

                      Setting number                      2345                                                     789                                             The shaded value indicates the default
                                                                                                                                                                   setting status.
             Minimum setting unit                                                              1C

Universal-input (Thermocouple/Platinum Resistance Thermometer) Models

Using Thermocouple Sensors, Control Mode Switch 5: OFF

                                  Input         K                      J          L                      T         U         N      R

                                  1,700                                                                                             1,700

                                  1,600

                                  1,500

             Temperature          1,400 1,300                                                                                1,300
             range                1,300
    901      (selected
             using switch)        1,200

78       23                       1,100

                                  1,000                   850                     850
                                    900

                                  800

                                  700

(Default setting: 0)              600

                                  500                                                               400            400

                                  400

                                  300              199.9                  199.9                             199.9
                                  200

                                  100

                                       0           0.0                      0.0                             0.0                               0
                                  -100 -99                                                                                    -99
                                                          -99                     -99               -99            -99
                                                                                                                              89
                      Setting number 0             1      2                 3     4                 567                                                            The shaded value indicates the default
                                                                                                                             1C                                   setting status.
             Minimum setting unit 1C 0.1C 1C 0.1C                                          1C          0.1C
                                                                                                                                                                   The shaded value indicates the default
Using Platinum Resistance Thermometers, Control Mode Switch 5: ON                                                                                                setting status.

                                  Input                   Pt100                                                    JPt100

    901      Temperature          1,000 850
             range                  900
             (selected
78       23  using switch)        800

                                  700

                                  600                                                               500
                                                                                                                                                              400
                                  500                                                     400
                                                                            200
                                  400

(Default setting: 0)              300              199.9                                                    199.9            200
                                  200                              99
                                  100                                                                              99

                                       0           0.0                      0     0                         0.0              0      0
                                  -100 -99
                                                          -99                                       -99            -99

                      Setting number 0             1      2                 34                      56789

             Minimum setting unit 1C 0.1C                                    1C                          0.1C            1C

                                                                                                                                                                                                           5
                                                                                                                                                                  E5CS

External Connection Diagram

         Sensor       Thermocouple (See note 3.)                                Platinum resistance thermometer                         Thermistor
                                                                                               (See note 3.)
Plug-in  Without  Voltage output models (See note 1.)                                                                                Voltage output models (See note 1.)
models   alarms                                                               Voltage output models (See note 1.)

                                 12 VDC,   Voltage                                           12 VDC,        Voltage                     12 VDC,             Voltage
                                  21 mA    output                                             21 mA         output                       21 mA              output

                                 45                                                          45                                         45

                  Relay output models                                         Relay output models                                    Relay output models

                                    45                                        A                                                                      45

                                                                                          45

                      (K, J)  3            6                                                 3              6                        3                      6

                              2            7                                  BB             2           7                           2                       7
                                                                                                1                                       1
                                    18                                                                8                                                   8

                                           100 to 240 VAC                                                    100 to 240 VAC                                      100 to 240 VAC
                                           24 VAC/VDC                                                        24 VAC/VDC                                          24 VAC/VDC
                                           (See note 2.)                                                     (See note 2.)                                       (See note 2.)

         With     Voltage output models Two alarm                             Voltage output models Two alarm                        Voltage output models
         alarms                                                                                                                      (See note 1.)
                  (See note 1.)               points                          (See note 1.)                 points

                  12 VDC, 21 mA      7           Alarm output 1               12 VDC, 21 mA           7        Alarm output 1        12 VDC, 21 mA
                         OUT           8         Alarm output 2                      OUT                8      Alarm output 2               OUT

                               5        9                                                  5             9                                        5
                            4                                                           4                                                      4

                  Relay output models                                         Relay output models                                    Relay output models

                                                             Alarm output                                              Alarm output                         Alarm output

                                    567                                                         567                                                  567

                                 4            8                                              4              8                        4                      8

                                 3            9                                    A     3                  9                        3                         9
                                                                              B
                                  2  1 11  10                                                2  1 11  10                                2            1 11   10

                                              100 to 240 VAC                          B                     100 to 240 VAC                                     100 to 240 VAC
                                              24 VAC/VDC                                                                                                       24 VAC/VDC
                                              (See note 2.)                                                 24 VAC/VDC                                         (See note 2.)

                                                                                                            (See note 2.)

Note: 1. The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not
            connect output terminals 4 or 5 to ground. Otherwise, unwanted current paths will cause measurement errors.

        2. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity.
        3. Be sure to check the sensor type before using multi-output (thermocouple/platinum resistance thermometer) models.

Nomenclature

E5CS-U Plug-in Models

                                                         Temperature display

Deviation indicators                                                          Output indicator
     Mode indicators
            Mode Key                                                          Alarm indicators
                                                                              Up Key

                                          Down key

                                                                                                                                                                                 6
                                                                                                                                                                      E5CS

Dimensions

Note: All units are in millimeters unless otherwise indicated.                                                   Terminal Arrangement
                                                                                                                      (Bottom View)
Controller

E5CS-U

                                                                 94.45                                           45                                          567
                                                                72.5
                               (7.75)                                                                         3            6                              4           8
                                 6.25
                  48 48                                                                                                                                 3           9

                                                                                                              2            7                                 2        10

                                                                                                                 18                                             1 11

                                                                                   44.8 44.8           Models without                                   Models with
                                                                                                              alarms                                         alarms

                                                                                                                 Panel Cutout Dimensions

                                                                                                                 45  +0.6
                                                                                                                      0
                                                                                                                                                                L

                  Note: The external dimensions are the same for both models                         45+00.6                  45+00.6
                          with and without alarms.

                                                                                                60 min.                       L = (48 N - 2.5)+01
                                                                                                                              Mounting side-by-side

                                                                                                                              (group mounting of N Controllers)

E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately)

(Without Alarms)

                                                                Adapter for        Panel Y92F-30 Adapter for flush mounting
                                                                flush mounting                                                    P3G-08
                                                                                                                                  Back Connecting Socket

                           58

                                       48                                          Tightening screws

                                                                                7               95

E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately)

(With Alarms)

                                                                Adapter for        Panel Y92F-30 Adapter for flush mounting
                                                                flush mounting                                                    P3GA-11
                                                                                                                                  Back Connecting Socket

                           58

                                       48                                          Tightening screws

                                                                                7               100

Note: Use the P2CF-08 and P3G-08 Sockets for models without alarms, and use the P2CF-11 and P3GA-11 Sockets for models with alarms.

                                                                                                                                                                            7
                                                                                                                                                                                E5CS

Accessories (Order Separately)

8-pin Sockets without Alarms                                                                                     Terminal Arrangement/
                                                                                                                  Internal Connections
P2CF-08 Front Connecting Socket         Eight, M3.5 7.5
                                        sems screws                                                                      (Top View)

                                                                                                 7.8 3     4.5                                           Mounting Hole Dimensions

                                                                                                                                        6543

                                                                                                                                                            Two, 4.5-dia. hole or two, M4

                                                                                                 Two,                                                       400.2
                                                                                                 4.5-dia.
                                                                                                 holes

                                 70 max.                                                                   35.4

                                                                                                                                        7812             Note: DIN Track mounting is also
                                                                                                                                                                  possible.

                                    4     50 max.                                                                         Note: The P2CF-08-E Socket with finger protection is also available.

                                                                                                           20.3 max.

P3G-08 Back Connecting Socket             27 dia.                                                                7                                       Terminal Arrangement
                                                                                                                           9                                  (Bottom View)

                                                                                                                                                                   3456

                                    45

                                                                                                                                                         2187

                                          45                                                           17        M3.5
                                                                                                 4.9                        8

                                                                                                           Note: The Y92A-48G Finger Safe Terminal Cover is also available.

11-pin Sockets with Alarms                                                                                       Terminal Arrangement/

P2CF-11 Front Connecting Socket Eleven, M3.5 7.5                                                               Internal Connections

                                                                                    sems screws  7.8 3     4.5              (Top View)

                                                                              70 max.            Two,                                   8765             Mounting Hole Dimensions
                                                                                                 4.5-dia.
                                                                                                 holes                                             4

                                                                                                                                                                                   Two, 4.5-dia. mounting holes

                                                                                                           35.4

                                                                                                                            9                      3                             400.2

                                                                                                                                        10 11 1 2        Note: DIN Track mounting is also
                                                                                                                                                                  possible.

                                 4        50 max.                                                          31.2 max. Note: The P2CF-11-E Socket with finger protection is also available.

P3GA-11 Back Connecting Socket            27 dia.                                                                                 4 73                   Terminal Arrangement
                                                                                                                                                              (Bottom View)
                                                                                                                    25.6
                                                                                                                                                          5678
                                                                                                 4.5 16.3 6.2                                            4
                                                                                                                              8.7
                                    45

                                                                                                                                                         3  9

                                                                                                                                                            2 1 11 10

                                          45                                                                                                          6

                                                                                                                Note: The Y92A-48G Finger Safe Terminal Cover is also available.

Note: Do not use any other types of Sockets. Doing so will adversely affect the accuracy.

Applicable Thermistors                                                                                     Hard Protective Cover

Use Element Interchangeable Thermistors (E52-THE5A, E52-                                                   The Y92A-48B Hard Protective Cover is available for the following
THE6D, and E52-THE6F) to connect to the E5CS-@GU. For details                                              applications.
on Sensors, refer to E52.
                                                                                                            To protect the set from dust and dirt.

                                                                                                            To prevent the panel from being
                                                                                                             accidentally touched causing displacement
                                                                                                             of set values.

                                                                                                            To provide effective protection against                   92A-48B

                                                                                                           water droplets.

                                                                                                                                                                                                                 8
                                                                                                                      E5CS

Safety Precautions

Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                      9
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

        Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

        Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

        Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2011.12
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2011 All Right Reserved.
http://www.ia.omron.com/
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

  E5CSQ1PXF E5CS-QGU-W AC100-240 E5CS-RKJU-W AC100-240 E5CS-Q1KJU-W AC100-240 E5CS-QKJU-W
AC100-240 E5CS-QPU-W AC100-240 E5CS-R1KJU-W AC100-240 E5CS-RPU-W AC100-240 E5CS-R1P E5CS-
RTU-W AC100-240 E5CS-R1PU-W AC100-240 E5CS-RGU-W AC100-240 E5CS-R1PDU-W AC/DC24 E5CS-Q1TU-
W AC100-240 E5CS-R1GU-W AC100-240 E5CS-R2TU-W AC100-240 E5CS-R1KJDU-W AC/DC24 E5CS-Q1PU-W
AC100-240 E5CS-Q1PX-F

小广播

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved